LG | LMNH242BHA0 | LG LMNH182BHA0 Owner’s Manual

LG
Multi Type Air Conditioner LG
OWNER'S MANUAL
Type: Ceiling Concealed Duct-High Static
IMPORTANT
Please read through this manual. It contains valuable
information about your air conditioner. This manual may
help save time and money by explaining proper product
maintenance and preventing improper use.
PRECAUTIONS
Pay close attention to precautions in order to prevent
potential hazards and damage from misuse or improper
installation. LG is not responsible for any damages caused
by misuse of the product.
P/No.: MFL57691101
Multi type Air Conditioner Owner’s Manual
TABLE OF CONTENTS
Safety Precautions ...................3
Prior to Operation.....................8
Operating Instructions ..............9
Maintenance and Service.......22
FOR YOUR RECORDS
Write the model and serial numbers here:
Model #
Serial #
You can find them on a label on the side of each unit.
Dealer's Name
Date Purchased
■ Staple your receipt to this page in the event you need
it to prove date of purchase or for warranty issues.
READ THIS MANUAL
Inside you will find many helpful hints on how to use
and maintain your air conditioner properly. Just a little
preventive care on your part can save you a great deal
of time and money over the life of your air conditioner.
You'll find many answers to common problems in the
chart of troubleshooting tips. If you review our chart of
Troubleshooting Tips first, you may not need to call
for service at all.
PRECAUTION
• Contact the authorized service technician for repair or
maintenance of this unit.
• Contact the installer for installation of this unit.
• The air conditioner is not intended for use by young
children or invalids without supervision.
• Young children should be supervised to ensure that
they do not play with the air conditioner.
• When the power cord is to be replaced, replacement
work shall be performed by authorized personnel only
using only genuine replacement parts.
• Installation work must be performed in accordance with
the National Electric Code by qualified and authorized
personnel only.
2 Multi type air conditioner
Safety Precautions
Safety Precautions
To prevent injury to the user or other people and property damage, the following instructions must be
followed.
■ Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classified
by the following indications.
WARNING
This symbol indicates the possibility of death or serious injury.
CAUTION
This symbol indicates the possibility of injury or damage to properties only.
■ Meanings of symbols used in this manual are as shown below.
Be sure not to do.
Be sure to follow the instruction.
■ Installation
Do not use a defective or
underrated circuit breaker.
Use this appliance on a
dedicated circuit.
WARNING
For electrical work, contact
the dealer, seller, a qualified
electrician, or an Authorized
Service Center.
• There is risk of fire or electric
shock.
• Do not disassemble or repair
the product. There is risk of fire
or electric shock.
Install the panel and the
cover of control box
securely.
Always install a dedicated
circuit and breaker.
• There is risk of fire or electric
shock.
• Improper wiring or installation
may cause fire or electric shock
Always ground the product.
• There is risk of fire or electric
shock.
Use the correctly rated
breaker or fuse.
• There is risk of fire or electric
shock.
Owner’s Manual 3
Safety Precautions
Do not modify or extend the
power cable.
• There is risk of fire or electric
shock.
For installation, always contact the
dealer or an Authorized Service Center.
• There is risk of fire, electric
shock, explosion, or injury.
Do not install, remove, or
re-install the unit by
yourself (customer).
• There is risk of fire, electric
shock, explosion, or injury.
Do not install the product on
a defective installation stand.
• It may cause injury, accident, or
damage to the product.
Be cautious when
unpacking and installing
the product.
• Sharp edges could cause injury.
Be especially careful of the
case edges and the fins on the
condenser and evaporator.
Be sure the installation area
does not deteriorate with age.
• If the base collapses, the air
conditioner could fall with it,
causing property damage,
product failure, and personal
injury.
■ Operation
Do not let the air conditioner run for a
long time when the humidity is very high
and a door or a window is left open.
• Moisture may condense and
wet or damage furniture.
Do not plug or unplug the
power supply plug during
operation.
• There is risk of fire or electric
shock.
4 Multi type air conditioner
Take care to ensure that power
cable could not be pulled out
or damaged during operation.
Do not place anything on
the power cable.
• There is risk of fire or electric
shock.
• There is risk of fire or electric
shock.
Do not touch(operate) the
product with wet hands.
Do not place a heater or
other appliances near the
power cable.
• There is risk of fire or electrical
shock.
• There is risk of fire and electric
shock.
Safety Precautions
Do not allow water to run
into electric parts.
Do not store or use flammable
gas or combustibles near the
product.
Do not use the product in a
tightly closed space for a
long time.
• It may cause There is risk of
fire, failure of the product, or
electric shock.
• There is risk of fire or failure of
product.
• Oxygen deficiency could occur.
Gasolin
When flammable gas leaks,
turn off the gas and open a
window for ventilation
before turn the product on.
If strange sounds, or small or
smoke comes from product. Turn
the breaker off or disconnect the
power supply cable.
• Do not use the telephone or
turn switches on or off.
There is risk of explosion or fire
• There is risk of electric shock or
fire.
Do not open the inlet grill of the
product during operation.
(Do not touch the electrostatic
filter, if the unit is so equipped.)
• There is risk of physical injury,
electric shock, or product
failure.
When the product is soaked
(flooded or submerged),
contact an Authorized
Service Center.
• There is risk of fire or electric
shock.
Ventilate the product from time to time
when operating it together with a stove, etc.
• There is risk of fire or electric shock.
Stop operation and close the window
in storm or hurricane. If possible,
remove the product from the window
before the hurricane arrives.
• There is risk of property
damage, failure of product, or
electric shock.
Be cautious that water
could not enter the product.
• There is risk of fire, electric
shock, or product damage.
Turn the main power off when cleaning or
maintaining the product.
• There is risk of electric shock.
Owner’s Manual 5
Safety Precautions
When the product is not be used for a long
time, disconnect the power supply plug or
turn off the breaker.
• There is risk of product damage or failure, or
unintended operation.
Take care to ensure that nobody could step
on or fall onto the outdoor unit.
• This could result in personal injury and product
damage.
CAUTION
■ Installation
Always check for gas
(refrigerant) leakage after
installation or repair of product.
• Low refrigerant levels may
cause failure of product.
Install the drain hose to ensure
that water is drained away
properly.
• A bad connection may cause
water leakage.
Keep level even when
installing the product.
• To avoid vibration or water
leakage.
90˚
Do not install the product where the
noise or hot air from the outdoor unit
could damage the neighborhoods.
• It may cause a problem for your
neighbors.
Use two or more people to lift
and transport the product.
• Avoid personal injury.
Do not install the product
where it will be exposed to
sea wind (salt spray) directly.
• It may cause corrosion on the product.
Corrosion, particularly on the condenser
and evaporator fins, could cause product
malfunction or inefficient operation.
■ Operation
Do not expose the skin directly to cool air
for long periods of time.
(Don't sit in the draft.)
• This could harm
to your health.
6 Multi type air conditioner
Do not use the product for special purposes, such as
preserving foods, works of art, etc. It is a consumer
air conditioner, not a precision refrigeration system.
• There is risk of
damage or
loss of property.
Safety Precautions
Do not block the inlet or
outlet of air flow.
• It may cause product failure.
Use a soft cloth to clean. Do
not use harsh detergents,
solvents, etc.
• There is risk of fire, electric
shock, or damage to the plastic
parts of the product.
Do not touch the metal parts of
the product when removing the
air filter. They are very sharp!
• There is risk of personal injury.
x
Wa Thinner
Do not step on or put
anyting on the product.
(outdoor units)
• There is risk of personal injury
and failure of product.
Do not drink the water
drained from the product.
• It is not sanitary and could
cause serious health issues.
Always insert the filter
securely. Clean the filter
every two weeks or more
often if necessary.
• A dirty filter reduces the efficiency
of the air conditioner and could
cause product malfunction or
damage.
• There are sharp and moving
parts that could cause personal
injury.
Use a firm stool or ladder
when cleaning or
maintaining the product.
Replace the all batteries in the
remote control with new ones
of the same type. Do not mix
old and new batteries or
different types of batteries.
• Be careful and avoid personal
injury.
• There is risk of fire or explosion
Do not recharge or disassemble the
batteries. Do not dispose of batteries in a
fire.
• They may burn or explode.
Do not insert hands or other
objects through the air inlet
or outlet while the product
is operated.
If the liquid from the batteries gets onto your skin
or clothes, wash it well with clean water. Do not
use the remote if the batteries have leaked.
• The chemicals in batteries could cause burns or
other health hazards.
Owner’s Manual 7
Prior to operation
Prior to Operation
Preparing for operation
1. Contact an installation specialist for installation.
2. Use a dedicated circuit.
Usage
1. Being exposed to direct airflow for an extended period of time could be hazardous to your health.
Do not expose occupants, pets, or plants to direct airflow for extended periods of time.
2. Due to the possibility of oxygen deficiency, ventilate the room when used together with stoves or
other heating devices.
3. Do not use this air conditioner for non-specified special purposes (e.g. preserving precision
devices, food, pets, plants, and art objects). Such usage could damage the items.
Cleaning and maintenance
1. Do not touch the metal parts of the unit when removing the filter. Injuries can occur when handling
sharp metal edges.
2. Do not use water to clean inside the air conditioner. Exposure to water can destroy the insulation,
leading to possible electric shock.
3. When cleaning the unit, first make sure that the power and breaker are turned off. The fan rotates
at a very high speed during operation. There is a possibility of injury if the unit’s power is
accidentally triggered on while cleaning inner parts of the unit.
Service
For repair and maintenance, contact your authorized service dealer.
8 Multi type air conditioner
Operating Instructions
Operating Instructions
Name and Function of Remote Controller
Wired Type
AUTO SWING
OPERATION
SET TEMP
Room Temp
Operation unit
Timer
03
SUB FUNCTION
1
HI
MED
LO
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
Time
On Off
Set no. Time 01
FAN SPEED
Program set
05
07
09
11
13
15
17
19
21
23
3
Signal receptor
7
8
9
10
11
12
2
Timer
Cancel
Program
Week
5
6
4
Holiday
Plasma
14
16
15
SET/CLR
Hour
Min
RESET
13
1. Operation display
Displays the operation conditions.
2. On/Off Button
Operation starts when this button is pressed,
and stops when the button is pressed again.
3. Set Temperature Button
Used to set the temperature when the
desired temperature is obtained.
4. FAN Operation Button
Used to circulate room air without cooling or
heating.
5. Fan Speed Button
Used to set desired fan speed.
6. Operation Mode Selection Button
Used to select the operation mode.
• Auto Operation Mode.
• Cooling Operation Mode.
• Soft Dry Operation Mode.
• Heating Operation Mode.(except cooling
model)
7. Timer Cancel Button
Used to cancel the timer.
8. Timer Set Button
Used to set the timer when the desired time
is obtained.
9. Week Button
Used to set a day of the week.
10. Program Button
Used to set the weekly timer.
11. Holiday Button
Used to set a holiday of the week.
12. Time Set Button
Used to set the time of the day and change
the time in the weekly timer Function.
13. Set and Clear Button
Used to set and clear the weekly timer.
14. Room Temperature Checking
Button
Used to check the room temperature.
15. Reset Button
Used to set the current time and clear the
setting time.
16. Plasma Air Clean Button
(optional)
Owner’s Manual 9
Operating Instructions
Wireless Type(Optional)
This air-conditioner is equipped with wired remote control basically. But if you want to be available
with wireless remote control, you pay for it.
1. FAN Operation Button
Used to circulate room air without cooling or
heating.
2.Cooling Operation Button
1
A/CL
11 3. Soft Dry Operation Button
4
10
3
9
5
2
6
7
8
Used to dehumidify without overcooling.
4. Heating Operation Button
(Heat pump model only)
5. Timer Set Button
Used to set the timer when the desired time is
obtained.
Then the wired remote controller is set up to 24
hours by an hour but the wireless remote controller
is set up to 7 hours by an hour. Therefore, if you
want to set over 7 hours, use the wired remote
controller.
6. Fan Speed Button
Used to set the desired fan speed.
7. On/Off Button
Operation starts when this button is pressed, and
stops when the button is pressed again.
8. Set Temperature Button
Used to set the temperature when the desired
temperature is obtained
9. Auto Operation Button
10. Plasma Air Clean Button(Optional)
11. Electric Heater Button(Optional)
Used to set the Electric Heater.
CAUTION
of handling the Remote Control
for handling the Remote Controller
• Aim at the signal receptor on the wired remote controller so as to operate.
• The remote control signal can be received at a distance of up to about 7m.
• Be sure that there are no obstructions between the remote controller and the signal receptor.
• Do not drop or throw the remote controller.
• Do not place the remote controller in a location exposed to direct sunlight, or near the heating unit, or any other
heat source.
• Block a strong light over the signal receptor with a curtain or etc. so as to prevent the abnormal operation.
(ex:electronic quick start, ELBA, inverter type fluorescent lamp)
10 Multi type air conditioner
Operating Instructions
Set the Current Time and a day of the Week
1
Press the '
' button.
Hour
Each time the button is pressed, the number is changed from 00 to 23.
You can set the number of the current hour.
AUTO SWING
OPERATION
SET TEMP
Room Temp
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
Time
Timer
Operation unit
2
Press the '
03
SUB FUNCTION
HI
MED
LO
Hour
On Off
Set no. Time 01
FAN SPEED
Program set
05
07
09
11
13
15
17
19
21
23
' button.
Min
Each time the button is pressed, the number is increased from 00 to 59.
You can set the number of the current minute.
AUTO SWING
OPERATION
SET TEMP
Room Temp
Min
Operation unit
3
Press '
Week
03
SUB FUNCTION
HI
MED
LO
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
Time
Timer
On Off
Set no. Time 01
FAN SPEED
Program set
05
07
09
11
13
15
17
19
21
23
' button.
Each time the button is pressed, a day of the week is shifted from sunday to saturday.
You can set the day of the week.
Week
AUTO SWING
OPERATION
SET TEMP
Room Temp
Operation unit
4
Press the '
RESET
03
SUB FUNCTION
HI
MED
LO
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
Time
Timer
On Off
Set no. Time 01
FAN SPEED
Program set
05
07
09
11
13
15
17
19
21
23
' button.
If you want to reset the current time and a day of the week, click the Reset button.
AUTO SWING
OPERATION
SET TEMP
Room Temp
RESET
Operation unit
03
SUB FUNCTION
HI
MED
LO
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
Time
Timer
On Off
Set no. Time 01
FAN SPEED
Program set
05
07
09
11
13
15
17
19
21
23
Owner’s Manual 11
Operating Instructions
Weekly Programming
1
Press the Program button.
The remote controller is displayed like a picture. Then '
Program
', '
Program set
AUTO SWING
OPERATION
' and '01' is blinked.
SET TEMP
FAN SPEED
Room Temp
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
Time
Operation unit
Timer
On Off
Set no. Time 01
2
Program set
05
07
09
11
13
15
17
19
21
23
Week
Press the '
' button.
Select Monday.
3
03
SUB FUNCTION
HI
MED
LO
Week
Change the timer setting until the desired time is set.
After you select a time, push the SET/CLR button once or one more time.
SET/CLR
Hour
Min
For Example if the air-conditioner is turned on from 6 to 8 and from 13 to 22 and turned off at other
time monday, display is as follows. (black bar indicates turn-on, white bar indicates turn-off.)
AUTO SWING
OPERATION
SET TEMP
Room Temp
Operation unit
4
03
SUB FUNCTION
HI
MED
LO
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
Time
Timer
On Off
Set no. Time 01
FAN SPEED
Program set
05
07
09
11
13
15
17
19
21
23
You can set turn on and turn off time by the day in a week as above.
12 Multi type air conditioner
Operating Instructions
Holiday Setting
If Tuesday is a holiday in this week, you may set a holiday.
Program
1
Press the Program button.
2
Press the Week button.
Select the Tuesday.
3
Press the Holiday button.
Week
Holiday
Then the remote controller will be displayed '
The outside rectangular means holiday.
'.
AUTO SWING
OPERATION
SET TEMP
Room Temp
4
Press the Program button again to finish holiday setting.
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
Time
Timer
Operation unit
03
SUB FUNCTION
HI
MED
LO
Program
On Off
Set no. Time 01
FAN SPEED
Program set
05
07
09
11
13
15
17
19
21
23
Timer Setting(Delay start/Pre-set stop)
This function is used to turn on or turn off in several hours.
Timer
1
Press the Timer button
2
Change the timer setting until the desired time is set.
to turn Timer on or off.
Hour
3
If you want to cancel the timer setting, press the Cancel button.
Min
Cancel
Owner’s Manual 13
Operating Instructions
Operation Mode
Cooling Mode
Cooling Mode
Soft Dry Mode
Soft Dry Mode
Heating Mode
Auto Mode
(Cooling Model)
Auto Mode
(Heat Pump Model)
Operation Procedure
1st
On/Off Button
AUTO SWING
OPERATION
SET TEMP
Room Temp
Operation unit
2nd
Operation Mode Selection Button
03
SUB FUNCTION
HI
MED
LO
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
Time
Timer
On Off
Set no. Time 01
FAN SPEED
Program set
05
07
09
11
13
15
17
19
21
23
3
1
3rd
Room Temperature Setting Button
Timer
Cancel
Program
Week
Holiday
Plasma
SET/CLR
Hour
4th
Indoor Fan Speed Selection Button
14 Multi type air conditioner
Min
RESET
2
4
Operating Instructions
Cooling Operation Mode
1
Press the On/Off Button.
2
Select Cooling Operation.
Press the Operation Mode Selection Button.
Each time the button is pressed, the operation mode is shifted in the arrow direction.
HEAT PUMP MODEL
Operation Display
AUTO SWING
OPERATION
SET TEMP
03
07
09
11
SET TEMP
Timer
13
15
17
Cooling Operation
03
SUB FUNCTION
AUTO SWING
07
09
11
SET TEMP
15
17
On Off
21Set no.
23 Time 01
19
Soft Dry Operation
03
SUB FUNCTION
AUTO SWING
07
09
11
SET TEMP
15
17
On Off
21Set no.
23 Time 01
19
Heating Operation
03
SUB FUNCTION
HI
MED
LO
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
Time
Operation unit
Timer
13
FAN SPEED
Room Temp
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
Program set
05
OPERATION
HI
MED
LO
Time
Operation unit
Timer
13
FAN SPEED
Room Temp
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
Program set
05
OPERATION
HI
MED
LO
Time
Operation unit
On Off
21 Set no.
23 Time 01
19
FAN SPEED
Room Temp
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
Program set
05
OPERATION
HI
MED
LO
Time
Operation unit
Timer
On Off
Set no. Time 01
AUTO SWING
SUB FUNCTION
FAN SPEED
Room Temp
Program set
05
07
09
11
13
15
17
19
21
23
Auto Operation
COOLING MODEL
Operation Display
AUTO SWING
OPERATION
SET TEMP
FAN SPEED
Room Temp
Time
Operation unit
Timer
On Off
Set no. Time 01
03
SUB FUNCTION
AUTO SWING
07
09
11
15
17
19
21
Set the temperature
lower than the room
temperature.
Operation unit
On Off
Set no. Time 01
23
03
SUB FUNCTION
AUTO SWING
Program set
05
07
09
OPERATION
OPERATION
SET TEMP
13
15
17
19
21
03
03
Program set
05
07
09
11
13
15
17
19
21
23
Auto Operation
SUB FUNCTION
HI
MED
LO
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
Time
Operation unit
On Off
Set no. Time 01
SUB FUNCTION
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
HI
MED
LO
Time
Operation unit
On Off
Set no. Time 01
23
FAN SPEED
Room Temp
Timer
11
FAN SPEED
Room Temp
SET TEMP
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
HI
MED
LO
Soft Dry Operation
AUTO SWING
Timer
FAN SPEED
Time
Timer
13
Cooling Operation
3
SET TEMP
Room Temp
Program set
05
OPERATION
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
HI
MED
LO
• The temperature can be set
within a range of 18°C ~ 30°C
by 1°C .
Program set
05
07
09
11
13
15
17
19
21
23
To raise the Temperature.
To lower the Temperature.
4
Set the fan speed.
Operation Display
AUTO SWING
OPERATION
SET TEMP
Room Temp
Operation unit
03
SUB FUNCTION
Program set
05
07
09
11
AUTO SWING
OPERATION
15
17
19
21
23
Operation unit
On Off
Set no. Time 01
03
FAN SPEED
SUB FUNCTION
Program set
05
07
09
11
AUTO SWING
OPERATION
15
17
19
21
23
Operation unit
On Off
Set no. Time 01
03
FAN SPEED
SUB FUNCTION
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
HI
MED
LO
Time
Timer
13
SET TEMP
Room Temp
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
HI
MED
LO
Time
Timer
13
SET TEMP
Room Temp
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
HI
MED
LO
Time
Timer
On Off
Set no. Time 01
FAN SPEED
Program set
05
07
09
11
13
15
17
19
21
23
• Select the fan speed in three steps- high, low, medium.
• The display shows high fan speed.
• Each time the button is pressed, the fan speed mode is shifted.
Owner’s Manual 15
Operating Instructions
Soft Dry Operation Mode
This mode dehumidifies without overcooling.
1
2
Press the On/Off Button.
Select Soft Dry Operation.
Press the operation Mode Selection Button.
Each time the button is pressed, the operation mode is shifted in the arrow direction.
HEAT PUMP MODEL
Operation Display
AUTO SWING
OPERATION
SET TEMP
FAN SPEED
Room Temp
Operation unit
03
Timer
Program set
05
07
09
11
OPERATION
SET TEMP
13
15
17
03
SUB FUNCTION
AUTO SWING
07
09
11
Timer
13
15
17
Soft Dry Operation
Cooling Operation
03
FAN SPEED
SUB FUNCTION
AUTO SWING
07
09
11
SET TEMP
15
17
19
On Off
21Set no.
23 Time 01
Heating Operation
03
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
Program set
05
07
09
11
13
15
17
Auto Operation
COOLING MODEL
Operation Display
AUTO SWING
OPERATION
SET TEMP
FAN SPEED
Room Temp
Operation unit
03
Program set
05
07
09
11
OPERATION
15
17
19
21
23
SET TEMP
Room Temp
Operation unit
On Off
Set no. Time 01
03
FAN SPEED
SUB FUNCTION
07
09
11
OPERATION
15
17
19
21
Soft Dry Operation
23
Operation unit
On Off
Set no. Time 01
03
FAN SPEED
SUB FUNCTION
HI
MED
LO
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
Time
Timer
13
SET TEMP
Room Temp
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
Program set
05
AUTO SWING
HI
MED
LO
Time
Timer
13
Cooling Operation
3
AUTO SWING
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
Time
Timer
On Off
Set no. Time 01
SUB FUNCTION
HI
MED
LO
Program set
05
07
09
11
13
15
17
19
21
23
Auto Operation
During Soft Dry Operation.
• The indoor fan speed is automatically set to the low, so the shift of the indoor fan speed is
impossible because it's already being set to the best speed for Dry Operation by Micom
Control.
16 Multi type air conditioner
SUB FUNCTION
HI
MED
LO
Time
Operation unit
Timer
13
FAN SPEED
Room Temp
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
Program set
05
OPERATION
HI
MED
LO
Time
Operation unit
On Off
21Set no.
23 Time 01
19
SET TEMP
Room Temp
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
Program set
05
OPERATION
HI
MED
LO
Time
Operation unit
On Off
21 Set no.
23 Time 01
19
FAN SPEED
Room Temp
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
Time
Timer
On Off
Set no. Time 01
AUTO SWING
SUB FUNCTION
HI
MED
LO
19
21
23
Operating Instructions
Heating Operation Mode (Heat pump model only)
1
2
Press the On/Off Button.
Select Heating Operation.
Press the Operation Mode Selection Button.
Each time the button is pressed, the operation mode is shifted in the arrow direction.
Operation Display
AUTO SWING
OPERATION
SET TEMP
Operation unit
03
07
09
Timer
11
13
15
17
Cooling Operation
3
FAN SPEED
03
Program set
05
07
09
11
Timer
13
15
17
19
OPERATION
SET TEMP
FAN SPEED
Room Temp
Operation unit
On Off
Set no. Time 01
03
SET TEMP
FAN SPEED
Room Temp
03
SUB FUNCTION
AUTO SWING
07
09
11
SET TEMP
Timer
13
15
17
Heating Operation
03
SUB FUNCTION
HI
MED
LO
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
Time
Operation unit
On Off
21Set no.
23 Time 01
19
FAN SPEED
Room Temp
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
Program set
05
OPERATION
HI
MED
LO
Time
Operation unit
Program set
05
07
09
11
13
15
17
19
21
23
Auto Operation
• The temperature can be set within a
range of 16˚C ~ 30˚C by 1˚C.
SUB FUNCTION
HI
MED
LO
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
Time
Timer
OPERATION
On Off
21Set no.
23 Time 01
Soft Dry Operation
Set the temperature.
AUTO SWING
SUB FUNCTION
AUTO SWING
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
HI
MED
LO
Time
Operation unit
On Off
21 Set no.
23 Time 01
19
SET TEMP
Room Temp
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
Program set
05
OPERATION
HI
MED
LO
Time
Timer
On Off
Set no. Time 01
AUTO SWING
SUB FUNCTION
FAN SPEED
Room Temp
To raise the Temperature.
Program set
05
07
09
11
13
15
17
19
21
23
To lower the Temperature.
4
Set the fan speed.
Operation Display
AUTO SWING
OPERATION
SET TEMP
Room Temp
Operation unit
03
SUB FUNCTION
07
09
11
OPERATION
SET TEMP
Room Temp
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
Program set
05
AUTO SWING
HI
MED
LO
Time
Timer
On Off
Set no. Time 01
FAN SPEED
15
17
19
21
23
Operation unit
On Off
Set no. Time 01
03
SUB FUNCTION
AUTO SWING
07
09
11
SET TEMP
Room Temp
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
Timer
13
15
17
19
21
Operation unit
On Off
Set no. Time 01
23
03
FAN SPEED
SUB FUNCTION
HI
MED
LO
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
Time
Program set
05
OPERATION
HI
MED
LO
Time
Timer
13
FAN SPEED
Program set
05
07
09
11
13
15
17
19
21
23
• Select the fan speed in three steps - high, low, medium.
• The display shows high fan speed
• Each time the button is pressed, the fan speed mode is shifted.
5
6
AUTO SWING
This air-conditioner is set to the hot start control in
order not to discharge the cold air during the
heating operation. This time, the remote controller
indicates ‘Preheat’.
If the outdoor temperature is too low during the
heating operation, this air-conditioner is set to the
defrosting operation and the remote controller
indicates ‘Defrost’.
OPERATION
SET TEMP
Room Temp
Operation unit
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
Program set
On Off
Set no. Time 01
03
AUTO SWING
OPERATION
05
07
09
11
13
SET TEMP
Room Temp
Operation unit
03
15
17
19
FAN SPEED
21
23
SUB FUNCTION
HI
MED
LO
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
Time
Timer
On Off
Set no. Time 01
SUB FUNCTION
HI
MED
LO
Time
Timer
FAN SPEED
Program set
05
07
09
11
13
15
17
19
21
23
Owner’s Manual 17
Operating Instructions
Auto Operation Mode
1
Press the On/Off Button.
2
To select Auto Operation, press the Operation Mode Selection button.
Each time the button is pressed, the operation mode is shifted in the direction of the arrow.
HEAT PUMP MODEL
Operation Display
AUTO SWING
OPERATION
SET TEMP
Operation unit
03
07
09
11
SET TEMP
Timer
13
15
17
03
SUB FUNCTION
AUTO SWING
07
09
11
Timer
13
15
17
Soft Dry Operation
Cooling Operation
FAN SPEED
03
SUB FUNCTION
AUTO SWING
07
09
11
SET TEMP
15
17
19
On Off
21Set no.
23 Time 01
Heating Operation
03
SUB FUNCTION
HI
MED
LO
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
Time
Operation unit
Timer
13
FAN SPEED
Room Temp
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
Program set
05
OPERATION
HI
MED
LO
Time
Operation unit
On Off
21Set no.
23 Time 01
19
SET TEMP
Room Temp
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
Program set
05
OPERATION
HI
MED
LO
Time
Operation unit
On Off
21 Set no.
23 Time 01
19
FAN SPEED
Room Temp
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
Program set
05
OPERATION
HI
MED
LO
Time
Timer
On Off
Set no. Time 01
AUTO SWING
SUB FUNCTION
FAN SPEED
Room Temp
Program set
05
07
09
11
13
15
17
19
21
Auto Operation
COOLING MODEL
Operation Display
AUTO SWING
OPERATION
SET TEMP
FAN SPEED
Room Temp
Time
Timer
Operation unit
On Off
Set no. Time 01
03
SUB FUNCTION
AUTO SWING
07
09
11
15
17
19
21
HEAT PUMP MODEL
AUTO SWING
OPERATION
SET TEMP
Operation unit
03
07
OPERATION
09
11
13
15
SET TEMP
03
15
17
19
21
07
09
11
17
19
21
03
SUB FUNCTION
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
HI
MED
LO
Program set
05
07
09
11
13
15
17
19
21
23
Auto Operation
To raise the Temperature.
To lower the Temperature.
23
FAN SPEED
SUB FUNCTION
HI
MED
LO
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
13
FAN SPEED
Time
Operation unit
On Off
Set no. Time 01
23
SET TEMP
Room Temp
Timer
13
SUB FUNCTION
Program set
05
OPERATION
Set the temperature upper or lower than the standard temperature.
The temperature can be set within a range of -2 ~ 2 by 1 level.
Time
Operation unit
On Off
Set no. Time 01
11
Program set
05
Room Temp
Timer
09
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
COOLING MODEL
AUTO SWING
07
HI
MED
LO
Time
Timer
On Off
Set no. Time 01
Program set
05
AUTO SWING
Set the temperature lower than the room themperature.
The temperature can be set within a range of 18˚C ~ 30˚C by 1˚C.
FAN SPEED
Room Temp
03
SUB FUNCTION
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
Soft Dry Operation
Cooling Operation
3
Operation unit
On Off
Set no. Time 01
23
FAN SPEED
HI
MED
LO
Time
Timer
13
SET TEMP
Room Temp
Program set
05
OPERATION
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
HI
MED
LO
15
17
19
21
23
(This indication will be shifted to the initial
Auto Mode Display state after 4 seconds.)
Cold Cool
Proper
Warm
Hot
To raise the Temperature.
(When you feel too cool or cold.)
To lower the Temperature.
(When you feel too warm or hot.)
During Auto Operation:
❏ You can switch the indoor fan speed.
❏ The system will automatically switch from the cooling mode to the heating mode as the room temperature
and set temperature.(Heat pump model only)
18 Multi type air conditioner
23
Operating Instructions
FAN Operation
1
Press the On/Off Button.
2
Press FAN Operation Button.
3
Each time Indoor Fan Speed button is pressed, the fan speed mode is shifted in the
arrow direction.
AUTO SWING
OPERATION
SET TEMP
Room Temp
Operation unit
03
SUB FUNCTION
07
09
11
OPERATION
15
17
19
21
• Fan speed is high.
23
Operation unit
On Off
Set no. Time 01
03
FAN SPEED
SUB FUNCTION
07
09
11
OPERATION
15
17
19
21
• Fan speed is low.
23
Operation unit
On Off
Set no. Time 01
03
FAN SPEED
SUB FUNCTION
HI
MED
LO
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
Time
Timer
13
SET TEMP
Room Temp
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
Program set
05
AUTO SWING
HI
MED
LO
Time
Timer
13
SET TEMP
Room Temp
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
Program set
05
AUTO SWING
HI
MED
LO
Time
Timer
On Off
Set no. Time 01
FAN SPEED
Program set
05
07
09
11
13
15
17
19
21
23
• Fan speed is medium.
Owner’s Manual 19
Operating Instructions
Child Lock Function
This is the Function that any children cannot used to the air-conditioner.
Operation procedure
AUTO SWING
OPERATION
SET TEMP
FAN SPEED
Room Temp
1. To set the Child-Lock Function
Press the Timer button and Minute Set button for three seconds. Then
the operation mode shift to child lock mode and it is displayed ‘CL’ in
the operation display.
When you press any button in this time, the remote controller is not
converted to any selected mode and the ‘CL’ is displayed in the remote
controller for about three seconds. But the Room Temperature function
is operated in spite of child lock mode.
Time
Timer
Operation unit
On Off
Set no. Time 01
03
Timer
Cancel
Program
Week
SUB FUNCTION
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
HI
MED
LO
Program set
05
07
09
11
13
15
17
19
21
Holiday
Plasma
SET/CLR
Hour
Min
RESET
2. To cancel the Child-Lock Function
Press the Timer button and Minute Set button for three seconds.
Then the child-lock mode is cancelled and the preselected mode is
displayed in the remote controller.
PLASMA Purification Operation (Optional)
1
AUTO SWING
OPERATION
SET TEMP
Room Temp
Operation unit
03
Timer
Cancel
Program
Week
SUB FUNCTION
3
Set the fan speed again with door of the remote
control closed. You can select the fan speed in
four steps-low, medium, high or Auto.
Each time the button is pressed, the fan speed
mode is shifted.
Program set
05
07
09
11
13
15
17
19
21
23
Holiday
Plasma
Min
Open the door on the remote control.
Press the PLASMA On/OFF button.
Operation will start when the button is pressed
and stop when the button is pressed again.
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
SET/CLR
Hour
2
HI
MED
LO
Time
Timer
On Off
Set no. Time 01
FAN SPEED
Press the On/Off button. The unit will
start.
RESET
20 Multi type air conditioner
❈ Air purifying operation (PLASMA)
with cooling, heating or any
other operations.
Plasma
23
Operation Details
• Cooling Operation Mode
When the room temperature is higher than the set temperature, it operates in cooling mode at the set
temperature, the set fan speed, and then it will be in automatically turn off when the room temperature
reaches the set temperature +0.5°C.
ROOM TEMP.
More 3 minutes
OPERATION START
SET TEMP. +0.5°C)
OPERATION STOP
SET TEMP. -0.5°C)
INDOOR FAN
OUTDOOR FAN/COMP
: SETTING FAN SPEED
: LOW COOL OPERATION
: COMP ON
: COMP OFF
Helpful information
Airflow speed and cooling capacity.
The cooling capacity indicated in the specification is
the value when the fan speed is set to high, and the
capacity will be lower at low or medium fan speed.
High fan speed is recommended when you wish to
cool the room quickly.
h
Hig ed
e
Sp
• After main power is on, Fan will start 7 seconds later.
Self-Diagnosis Function
'CH' will flash in the remote controller display when a problem occurs. Then please contact your dealer.
Owner’s Manual 21
Maintenance and Service
Maintenance and Service
CAUTION: Before performing any maintenance, turn off the main power to
the system.
Grille, Case, and Remote Control
❏ Turn the system off before cleaning. To clean, wipe with
a soft, dry cloth. Do not use bleach or abrasives.
NOTICE
❏ Never use any of the followings:
• Water hotter than 40°C
Could cause deformation and/or
discoloration.
• Volatile substances
Could damage the surfaces of the air
conditioner.
Supply power must be disconnected before
cleaning the indoor unit.
SI
Be
Air outlet vent
N NER
n zene
SCO
U RIN G
C LB
A R GER
Air filters
Air Filter
The air filters behind Indoor unit
(the suction side) should be checked and cleaned once
every 2 weeks or more often if necessary.
1. Clean the filter with a vacuum or warm, soapy
water.
• If very dirty, wash with a solution of
detergent in lukewarm water.
• If hot water (50°C or more) is used,
filter may be deformed.
2. After washing with water, dry well in the
shade.
3. Re-install the air filter.
22 Multi type air conditioner
Maintenance and Service
When the air conditioner is not going to be used for a long time.
When the air conditioner is to
be used again.
When it is not going to be used for
a long time.
1
Operate the air conditioner on Air circulation
mode (Refer to page 19) for 2 to 3 hours.
■ Check that the air inlet and outlet of the
indoor/outdoor unit are not blocked.
• This will dry out the internal parts.
2
Turn off the circuit breaker.
Helpful information
CAUTION
CAUTION
Turn off the circuit breaker when the air conditioner
is not going to be used for a long time.
Dirt may collect and may cause a fire.
The air filters and your electiric bill.
If the air filters become clogged with dust, the
cooling capacity will drop, and 6% of the
electricity used to operate the air conditioner will
be wasted.
Operation Tips
Do not overcool the room.
This is not good for the health
and wastes electricity.
Clean the air filter regularly.
Blockages in the air filter
reduce the airflow and lower
cooling and dehumidifying
effects. Clean at least once
every two weeks.
Keep blinds or curtains
closed.
Make sure that the doors
and windows are shut tight.
Do not let direct sunshine
enter the room when the air
conditioner is in operation.
Avoid opening doors and
windows as much as possible
to keep the cool air in the
room.
Ventilate the room
occasionally.
Since windows are kept
closed, it is a good idea to
open them and ventilate the
room now and then.
Owner’s Manual 23
Maintenance and Service
Before you call for service...
Troubleshooting Tips! Save time and money!
Check the following points before requesting repairs or service.... If the malfunction persist, please contact your
dealer.
Case
Explanation
See page
The air conditioner does not
operate.
• Have you made a mistake in timer operation?
• On first starting, the indoor unit operates in
fifteen seconds.
• Has the fuse blown or has the circuit breaker
been tripped?
• Check that this is not a damp smell exuded by
the walls, carpet, furniture or cloth items in the
room.
• Condensation occurs when the airflow from the
air conditioner cools the warm room air.
• This is the protector of the mechanism.
• Wait about three minutes and operation will
begin.
• Is the air filter dirty? See air filter cleaning
instructions.
• The room may have been very hot when the
room air conditioner was first turned on. Allow
time for it to cool down.
• Has the setting temperature been set
incorrectly?
• Are the indoor unit's air inlet or outlet vents
obstructed?
• For a noise that sounds like water flowing.
-This is the sound of freon flowing inside the air
conditioner unit.
• For a noise that sounds like the compressed air
releasing into atmosphere.
-This is the sound of the dehumidifying water
being processed inside the air conditioning
unit.
• This sound is generated by the
expansion/contraction of the inlet grille, etc. due
to changes of temperature.
• Has the circuit breaker been tripped?
13
The room has a peculiar odor.
It seems that condensate is
leaking from the air Conditioner.
Air conditioner does not operate
for about 3 minutes when restart.
Does not cool or heat effectively.
The air conditioner operation is
noisy.
Crack sound is heard.
Remote control display is faint, or
no display at all.
24 Multi type air conditioner
-
22
15, 17
-
-
-
Maintenance and Service
Product Specifications
Details of LG serial No.
1
2
3
4
5
6
7
8
9
10
Code
Detail
Code of Model
1
Year
0~9
(Digit)
The last digit of year
ex) 1997 7, 2000
01~12
(Digit)
Month
ex) March
2,3
Month
Main Service Part List
Meaning
0
03, August
4
Nation
A~Z
(Alphabet)
Where manufactured
ex) K Korea, C China
5
Product
A~Z
(Alphabet)
ex) A
6~10
Serial No.
0~9
(Digit)
NO
PART NAME
1
COMPRESSOR
2
MOTOR
3
MAIN PCB ASSY
4
REMOCON
5
TRANSFORMER
08
Airconditioner
Production Quantity
H. G. IBRAHIM SHAKER COMPANY, LTD.
SERVICE CENTER
* JEDDAH
P. O. BOX 50, JEDDAH 21411 KINGDOM OF SAUDI ARABIA
TEL NO. : 6422952 / 6425527
* RIYADH
P. O. BOX 15, RIYADH 11411 KINGDOM OF SAUDI ARABIA
TEL NO. : 4020570
* AL-KHOBAR
P. O. BOX 78, AL-KHOBAR 31952 KINGDOM OF SAUDI ARABIA
TEL NO. : 8943714
Owner’s Manual 25