LG | LP-H55BTE1 | LG LP-H55BTE1 Owner’s Manual

Before using your air conditioner please read this
manual carefully and keep it for future reference.
MODEL: PT Chassis
Prior to installation, this air-conditioning unit
must be submitted for approval by the utility
service which provides electricity (EN 61000-3
Norm).
ENGLISH
Floor Standing Type
Air Conditioner
OWNER'S
MANUAL
Safety Precautions
Operating Instructions
Care and Maintenance
Troubleshooting Tips
Safety precautions
Safety Precautions
Warning ................................2
Caution .................................4
Operating Instructions
Features and Specifications....6
Indoor Unit Controls and
Indicators ..............................7
Name and Function-Remote
Control...................................8
Air conditioner operation.....10
To prevent injury to the user or other people and property damage, the
following instructions must be followed.
■ Incorrect operation due to ignoring of instruction will cause harm or
damage, the seriousness is classified by the following indications.
WARNING
WARNING
This symbol indicates the possibility of death or serious injury.
CAUTION
CAUTION
This symbol indicates the possibility of injury or damage to
properties only.
Care and Maintenance
During the season ..............18
When the air conditioner is not
going to be used for a long time..19
Operation Tips ....................19
Troubleshooting tips
Before You
Call For Service ...............20
Installation precautions
WARNING
WARNING
■ Do not install, remove and re-install the unit by yourself.
Improper installation will cause water leakage, electrical shock, or
fire. Please consult authorized dealer or specialist for the
installation work.
WARNING
WARNING
Do not expand or twist power cables.
Open windows for ventilation before operating
a remote control or air conditioner when gas
emits.
• Otherwise, it may cause electrical shock or fire.
(Contact a sale representative or a professional
shop if electrical works are required.)
• Otherwise, it may cause explosion or fire.
Do not use inflammable gas or inflammable
substance (benzene, gasoline, thinner) near
this product.
Always install both leakage breakers and
dedicated switches.
• Otherwise, it may cause explosion or fire.
• Non-installation may cause disorder of the
product or electrical shock.
Ensure that water enters into the product.
Always execute grounding works.
• Otherwise, it may cause disorder of the product
or electrical shock.
(when water enters, firstly turn the main switch
off and contact the sale representative.)
• Non-grounding may cause disorder of the
product or electrical shock.
2
WARNING
WARNING
Do not place objects around an outdoor
device for children to stand on it.
• Otherwise, it may cause electrical shock.
• Children may fall down outside.
Do not open air intake hole of indoor/outdoor
devices during operation.
Do not randomly disassemble or modify the
product.
• Otherwise, it may cause electrical shock.
• Otherwise, it may cause disorder of the product
or electrical shock.
Exercise caution so that water does not enter
into electrical parts.
Do not use power cables near heating tools.
• Otherwise, it may cause disorder of the product
or electrical shock.
Always execute bolting the control cover.
• Otherwise, it may cause electrical shock or fire.
Do not touch a leakage breaker or dedicated
switch with the wet hands.
Turn the main switches off if there are strange
sound, smell or smoke from the product.
• Otherwise, it may cause electrical shock.
• Otherwise, it may cause electrical shock or fire.
Do not use dedicated switches that are
damaged or loose.
Do not use the product near fire or flame.
• Otherwise, it may cause electrical shock or fire.
• Otherwise, it may cause fire.
3
ENGLISH
Do not connect grounding wires to a window
sash or a tap.
Safety Precautions
Operating Instructions
Care and Maintenance
Troubleshooting Tips
CAUTION
• Contact the authorized Service technician for repair or maintenance of this unit.
• Contact the installer for installation of this unit.
• The air conditioner is not intended for use by young children or infirm persons without
supervision.
• The appliance is not intended for use by young children or infirm persons without supervision.
• Young children should be supervised to ensure that they do not play with the appliance.
• If the supply flexible cord is damaged, it must be replaced by the manufacturer or the
manufacturer’s service agent or similary qualified person in order to avoid hazard.
CAUTION
CAUTION
Do not use the product for special use or in
special location such as animal/plant,
precision device, art works.
Install drain hoses so that drain can be surely
done.
• Otherwise, it may cause damage of animals,
plants and property.
• Condensation water may inflow into the indoor if
no water is properly discharged.
Do not touch with connection pipes so they
are very hot.
Do not install the product for safety at a
position that there is concern of drop such as
outside wall and outside of veranda.
• Otherwise, it may cause personal damage.
• Dropping of the product may cause personal
damage.
Install the product so that noise from the
outdoor device or hot wind does not give
inconvenience to neighborhoods.
Frequently perform ventilation during
operation together with combustion devices.
• Otherwise, it may cause dispute with
neighborhoods.
• Insufficient supply of oxygen may cause
difficulty of respiration.
Do not put the hands or bars into the blowing
hole of indoor devices or the air discharge
hole of the outdoor devices. Do not touch a
heat exchanger with the hands even in nonoperation.
Turn the main switch when not using it for a
long time.
• Otherwise, it may cause personal damage
(there is specially danger of personal damage
since the pin of a heat exchanger is sharp).
• Otherwise, it may cause disorder of the product
or fire.
4
CAUTION
CAUTION
Avoid excessive cooling and execute
ventilation once or twice times for two hours
during long-term use.
• There is concern of electrical shock, fire or
deformity.
• Strong wind for a long time may give harm to
health.
Always turn the main switch off for cleaning.
Use sooth cloths for cleaning, not powerful
cleaning agent such as waxes and thinners.
• Otherwise, it may cause electrical shock.
• Otherwise, appearance of the product may
become worse due to change of color of the
product or scratching of surface of the product.
Use filters with secure fixing and execute
filter cleaning once a week.
Do not drink water discharged from the air
conditioner.
• Operation without filter may cause disorder.
• Otherwise, it may cause a stomach disorder.
Do not put obstacles around the intake hole
or the drain hole.
Keep the product level during installation of
outdoor devices.
• Otherwise, it may cause damage of the product
or accidents.
• Unbalance may result in vibration sound.
5
ENGLISH
Do not install the product at a bathroom, a
location disclosed to rains or winds or a
place where water splashes.
Safety Precautions
Features and Specifications
Features
1 Design for cooling and
heating
7 Removable air filter
2 Super energy efficiency
Care and Maintenance
Operating Instructions
3 Micom control
Troubleshooting Tips
6 2 cooling/heating speeds
8 Anti-Bacteria filter
9 3 minutes delay circuit
4 Whisper quiet operation
5 Wireless remote control
Specifications
Air Outlet Vent
Air Intake Vent
(Rear)
Remote Signal
Receptor
Air Outlet
Vent
Air Intake Vent
Piping
6
Indoor Unit Controls and Indicators
7
8
6
5
(Heat Pump Model)
14 9
7
10
6
5
(Cooling Model)
1
START/STOP BUTTON
Operation starts when this button is
pressed and stops when the button is
pressed again.
2
OPERATION MODE SELECTION BUTTON
Used to select the operation Mode.
3
ROOM TEMPERATURE SETTING
BUTTONS
Used to select the room temperature.
4
14 13
FAN OPERATION LAMP
6
COOLING OPERATION LAMP
7
SOFT DRY OPERATION LAMP
8
HEATING OPERATION LAMP
9
DEFROST OPERATION LAMP
11
12
11
2
4
1
3
2
4
1
3
10
AUTO OPERATION LAMP
11
OFF TIMER OPERATION LAMP
12
AUTO AIR FLOW OPERATION
LAMP
13
JET COOL OPERATION LAMP
14
OUTDOOR UNIT OPERATION
LAMP
INDOOR FAN SPEED SELECTION
Used to select fan speed in three
steps-low, med, high.
5
12
7
ENGLISH
Display
Safety Precautions
Operating Instructions
Name and Function-Remote Control
Control
1 Signal Transmitter
• Transmits the signals to the floor standing
type air conditioner
1
2 Operation Display of the Remote Control
3 Indoor Fan Speed Selection Button
2
11
4
12
10
7
13
4 Cooling ON Button
5 Temperature Setting Buttons
8
6 Power ON/OFF Button
14
15
3
6
• To select the desired fan speed in two steps
[Low, High]
• Operation will start when this button is
pressed, and stop when the button is pressed
again.
7 Auto Airfloor Direction Centrol Button
• The horizontal louvers swing up and down.
5
8 Auto Airflow Direction Control Button
• The vertical louvers swing left and right.
(Heat pump Model)
9
10
11
12
2
11
4
12
9
7
13
Auto Mode Operation Button (Cooling Model Only)
Heating Button (Heat Pump Model)
Indoor Fan Operation Button
Timer Set Button
• Each time the button is pressed, the mode is
changed in the following process.
Time set (1, 2, 3, 4, 5, 6, 7 hours)
If you select "0:00" the off Timer function will
be cancelled.
8
13 Soft Dry Operation Button
14
15
14 JET Cool Operation Lamp
3
6
15 Auto Air Flow Operation Lamp
5
Troubleshooting Tips
Care and Maintenance
1
Wireless Remote Control Puts all functions at your fingertips
Handling the remote control
(Cooling Model)
• Aim at the signal receptor on the floor standing type air
conditioner when operating.
• The remote control signal can be received at a distance of up to
about 7meters.
• Be sure that there are no obstructions between the remote
control and the signal receptor.
• Do not drop or throw the remote control.
• Do not place the remote control in a location exposed to direct
sunlight, or next to a heating unit, or other heat source.
8
1
ENGLISH
Remote Control Preparation
How to mount onto a wall
Use the screws to secure the holder to the wall or attach the holder side of indoor
unit.
2
To insert the remote control to the holder.
Insert
Pull
How to insert batteries
• Do not use rechargeable
batteries such batteries
as different from standard
dry cells in shape,
dimensions, and
performance.
Remove the cover from the
back of the remote controller.
• Slide the cover according to
the arrow direction.
Insert two batteries.
• Be sure that the (+) and (-)
directions are correct.
• Be sure that both batteries
are new.
• Change the batteries with
a new one if the remote
control does not work
properly after using for an
extended length of time.
Re-attach the cover.
• Slide the cover into back
position.
9
1
Cooling Operation
Soft Dry Operation
Heating Operation
(Heat pump Model)
Cooling Operation
Auto Operation
Soft Dry Operation
(Cooling Model)
2
How to use the Fan speed Button
• Each time the Fan speed Button is pressed, the Fan speed is shifted in the arrow direction.
Troubleshooting Tips
Care and Maintenance
How to use the Operation Mode Button
• Each time the Operation Mode Selection Button is pressed, the Operation Mode is
shifted in the arrow direction.
Operating Instructions
Safety Precautions
Air conditioner operation
High
10
Low
1
ENGLISH
Cooling Operation Mode
3
Press the Start/Stop Button.
2
Select Cooling Operation.
Press the Operation Mode Selection Button.
Press the Cooling Operation Button on the remote controller.
3
Set the temperature lower than the room temperature.
The temperature can be set within a range of 16°C~30°C by 1°C.
To raise the temperature
To lower the temperature
4
Set the Fan Speed.
❑ Each time the Fan Speed Button is
pressed, the Fan Speed mode is
shifted in the arrow direction.
11
Safety Precautions
Operating Instructions
Care and Maintenance
Soft Dry Operation
4
1
Press the Start/Stop Button.
2
Select Soft Dry Operation.
Press the Operation Mode Selection Button.
Press the Soft Dry Operation Button on the remote controller.
3
Set the temperature lower than the room temperature.
The temperature can be set within a range of 16°C~30°C by 1°C.
To raise the temperature
Troubleshooting Tips
To lower the temperature
During softy Dry Operation
• The indoor fan speed is automatically set to low and can be set fan speed.
12
1
Press the Start/Stop Button.
2
Select heating Operation.
Press the Operation Mode Selection Button.
Press the heating Operation Button on the remote controller.
3
Set the temperature upper than the room temperature.
The temperature can be set within a range of 16°C~30°C by 1°C.
To raise the temperature
To lower the temperature
4
Set the Fan Speed.
❑ Each time the Button is pressed, the
Fan Speed mode is shifted.
13
ENGLISH
Heating Operation Mode(Heat Pump Model)
5
Safety Precautions
Operating Instructions
Care and Maintenance
6 Auto Operation Mode(Cooling Model Only)
1
Press the Start/Stop Button.
2
Select Auto Operation.
Press the Operation Mode Selection Button.
Press Auto Operation Button.
3
Set the temperature upper or lower than the standard temperature.
The temperature can be set within a range of
by 1 level.
Cold Cool Proper
Warm Hot
Troubleshooting Tips
(This indication will be shifted to the initial Auto Mode Display state after 4 seconds.)
To raise the temperature. (When you feel too cool or cold)
To lower the temperature. (When you feel too warm or hot)
During Auto Operation
• It is impossible to switch the indoor fan speed because of being already set to the best
conditioner by fuzzy rule.
14
1
3
Press the Start/Stop
Button.
2
Press Fan Operation Button.
Set the Fan Speed.
MODE
❑ Each time the Button is pressed, the
Fan Speed mode is shifted.
8 Airflow Direction Procedure
1
Press the Start/Stop Button.
2
Press the Auto Swing Button and then
louvers will swing left and right.
Press the Airflow Direction
Control Button again to set
the Vertical louver at the
desired airflow direction.
The vertical louver swing left and right.
(Operation will start when the button is pressed,
and stop when the button is pressed again.)
15
ENGLISH
Fan Operation Mode
7
Safety Precautions
1
2
3
Troubleshooting Tips
Care and Maintenance
Operating Instructions
OFF Timer Setting Procedure(OFF TIMER Setting, or CANCEL)
9
Press the Start/Stop Button.
Select Function.
Press the Timer Button.
• If you press the button, the selected off timer is displayed as follows;
• If you select ‘
4
’, the Off Timer function will be cancelled.
When you finish the Off Timer setting, the Timer indicator lights off.
After 4 seconds
5
During off-timer operation if you press the Timer Button, the rest time will be displayed.
16
1
Press the fan speed button and high temperature setting buttons simultaneously for 3
seconds.
The unit will respond with beep.
After 3 second,
it will shift
2
After 3 seconds,
it will shift
During Child Lock Operation
❶ Whenever you press any Button on Display Panel, it will immediately display
“
”, which means Display panel is Locked.
❷ All the Button on the indoor unit Display panel will not work.
❸ But the Button on the remote controller will work.
3
For releasing child lock Operation.
Press the fan speed and high temperature setting buttons simultaneously for 3 seconds
again.
The unit will rospond with beep, Child Lock Operation will removed.
After pressing
the buttons
it will shift
immediately
11
After 3 seconds,
it will shift
What is Auto Restarting Operation
• In case the power comes on again after a power failure Auto Restarting Operation is designed
to operate automatically to the previous operating condition.
• If the power comes to be failure while off-timer operation, Auto Restarting Operation is
cancelled and function returns to the previous mode.
17
ENGLISH
10 Child Lock Operation Procedure
CAUTION: Before performing any maintenance, turn off the main power to the system.
During the season
Cleaning of the air filters.
Recommended about once every two weeks
1
Remove the Air Filter.
Take hold of the tab and pull slightly
forward to remove the filter.
2
Cleaning of the air conditioner
Clean.
• To remove the dust adhering to the
filters, either use a vacunm cleaner, or
wash them in water and dry in the
shade.
• Re-insert the filter to the original
position.
Never use any of the followings.
• Don’t wash with water.
• Wipe with a soft dry cloth.
• Water hotter than 40°C.
Could cause deformation and/or discoloration.
• Volatile substances.
Could damage the surfaces of the air
conditioner.
There’s the
danger of
electrical
shock.
Troubleshooting Tips
Care and Maintenance
Operating Instructions
Safety Precautions
Care and Maintenance
18
At the start of the season
At the end of the season
1
Operate the air conditioner at the
following settings for 2 to 3 hours.
• Type of operation : Cooling.
• Temperature setting : 30°C.
2
This will dry out the internal mechanisms.
Remove the batteries from the Remote
Control.
3
1
Clean the air filters, re-insert, then
operate the air conditioner.
2
Be sure that nothing obstructs the air
outlet and intake vents.
Turn off the circuit breaker.
CAUTION
CAUTION
Turn off the circuit breaker when the air
conditioner is not going to be used for a long
time.
Dirt may collect and may cause a fire.
Operation Tips
Do not overcool the room.
Keep blinds or curtains closed.
Keep the room temperature
uniform.
This is not good for your health
and wastes electricity.
Do not let direct sunshine enter the
room when the air conditioner is in
operation.
Adjust the vertical and horizontal
airflow direction to ensure a
uniform temperature in the room.
Make sure that the doors and
windows are shut tight.
Clean the air filter regularly.
Ventilate the room occasionally.
Avoid opening doors and windows
as much as possible to keep the
cool air in the room.
Blockages in the air filter reduce
the airflow and lower cooling and
dehumidifying effects. Clean at
least once every two weeks.
Since windows are kept closed, it
is a good idea to open them and
ventilate the room now and then.
19
ENGLISH
When the air conditioner is not going to be used for a long time.
Troubleshooting Tips
Care and Maintenance
Operating Instructions
Safety Precautions
Before you call for service...
?
Troubleshooting Tips! Save time and money!
Check the following points before requesting repairs or service.... If the fault persists, please
contact your dealer or service center.
Case
Does not operate.
Explanation
See page
• Have you made a mistake in timer operation?
• Has the fuse blown or has the circuit breaker been
tripped?
• Is the power Switch at Off?
• Is the unit at the starting of Heating Operation?
If yes, Hot-start is activating.
• Is the unit in the Deicing?
If yes, wait for finishing the Deicing.
-
The room has a peculiar
odor.
• Check that this is not a damp smell exuded by the
walls, carpet, furniture, or cloth items in the room.
-
It seems that condensation is
leaking from the air
conditioner.
• Condensation occurs when the airflow from the air
conditioner cools the warm room air.
Air conditioner does not
operate for about 3 minutes
when restarted.
• This is the Protection device of the air conditioner .
• Wait about three minutes and operation will begin.
• If the airflow begins before its temperature become
warm, it will cause an undesired cooling effect. In
order to prevent this, the airflow will not begin until
it is sufficiently warm.
Does not cool or heat
effectively.
• Is the air filter dirty? See air filter cleaning
instructions.
• The room may have been very hot when the room
air conditioner was first turned on. Allow time for it
to cool down.
• Has the temperature been set incorrectly?
• Are the indoor unit's air inlet or outlet vents
obstructed?
The air conditioner operation
is noisy.
• For a noise that sounds like water flowing.
-This is the sound of freon flowing inside the air
conditioner unit.
• For a noise that sounds like the compressed air
releasing into atmosphere.
-This is the sound of the dehumidifying water being
processed inside the air conditioning unit.
-
18
-
-
9
NOTE
WATER RESISTANT: The outdoor side of this appliance is WATER RESISTANT.
The indoor side is not water resistant and should not be exposed to excess water.
20
Details of LG serial No.
2
3
4
5
6
7
8
9 10
Code
Detail
Code of Model
1
Year
0~9
(Digit)
The last digit of year
ex) 1997 → 7, 2000 → 0
Meaning
2,3
Month
01~12
(Digit)
Month
ex) March → 03, August → 08
4
Nation
A~Z
(Alphabet)
Where manufactured
ex) K → Korea, C → China
5
Product
A~Z
(Alphabet)
ex) A → Airconditioner
6~10
Serial No.
0~9
(Digit)
Production Quantity
■ Service Centers
H. G. IBRAHIM SHAKER COMPANY, LTD.
SERVICE CENTER
* JEDDAH
:
P. O. BOX 50, JEDDAH 21411 KINGDOM OF SAUDI ARABIA
TEL NO. : 6422952 / 6425527
* RIYADH
:
P. O. BOX 15, RIYADH 11411 KINGDOM OF SAUDI ARABIA
TEL NO. : 4020570
* AL-KHOBAR
:
P. O. BOX 78, AL-KHOBAR 31952 KINGDOM OF SAUDI ARABIA
TEL NO. : 8943714
In case of parts being disordered,
please contact with SVC center:
and check the replacement parts code.
21
ENGLISH
1
Troubleshooting Tips
Care and Maintenance
Operating Instructions
Safety Precautions
NOTE
22
P/No.: 3828A30069M
Printed in Korea
Download PDF

advertising