LG | TPNH508TLC5.ANWBAEC | LG TPNH508TLC5.ANWBAEC Owner’s Manual

ENGLISH
MFL66984309
OWNER’S MANUAL
AIR CONDITIONER
Please read this manual carefully before operating
your set and retain it for future reference.
TYPE : CONVERTIBLE
TYPE:
MFL68579904
P/NO.:MFL68579904
www.lg.com
Floor Standing- Type Air Conditioner Owner’s Manual
TABLE OF CONTENTS
FOR YOUR RECORDS
Safety Precautions.................3
Write the model and serial numbers here:
Model #
Serial #
Operating Instructions...........8
You can find them on a label on the side of each unit.
Dealer's Name
Date Purchased
Maintenance and Service ....2
Staple your receipt to this page in the event you need it
to prove date of purchase or for warranty issues.
READ THIS MANUAL
Inside you will find many helpful hints on how to use and
maintain your air conditioner properly. Just a little
preventive care on your part can save you a great deal
of time and money over the life of your air conditioner.
You'll find many answers to common problems in the
chart of troubleshooting tips. If you review our chart of
Troubleshooting Tips
service at all.
first, you may not need to call for
PRECAUTION
• Contact the authorized service technician for repair or
maintenance of this unit.
• Contact the installer for installation of this unit.
• The air conditioner is not intended for use by young
children or invalids without supervision.
• Young children should be supervised to ensure that
they do not play with the air conditioner.
• When the power cord is to be replaced, replacement
work shall be performed by authorized personnel only
using only genuine replacement parts.
• Installation work must be performed in accordance
with the National Electric Code by qualified and
authorized personnel only.
2 Floor Standing-Type Air Conditioner
Safety Precautions
To prevent injury to the user or other people and property damage, the following instructions
must be followed.
Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is
classified by the following indications.
WARNING
This symbol indicates the possibility of death or serious injury.
CAUTION
This symbol indicates the possibility of injury or damage.
Meanings of symbols used in this manual are as shown below.
Be sure not to do.
Be sure to follow the instruction.
WARNING
Installation
Do not use a defective or
underrated circuit breaker.
Use this appliance on a
dedicated circuit.
• There is risk of fire or electric
shock.
Install the panel and the
cover of control box
securely.
• There is risk of fire or electric
shock.
For electrical work, contact
the dealer, seller, a qualified
electrician, or an Authorized
Service Center.
• Do not disassemble or repair the
product. There is risk of fire or
electric shock.
Always install a dedicated
circuit and breaker.
• Improper wiring or installation
may cause fire or electric shock
Always ground the product.
• There is risk of fire or electric
shock.
Use the correctly rated
breaker or fuse.
• There is risk of fire or electric
shock.
Owner's Manual 3
ENGLISH
Safety Precautions
Safety Precautions
Do not modify or extend the
power cable.
• There is risk of fire or electric
shock.
For installation, always contact the
dealer or an Authorized Service Center.
• There is risk of fire, electric
shock, explosion, or injury.
Do not install, remove, or reinstall the unit by yourself
(customer).
• There is risk of fire, electric
shock, explosion, or injury.
Do not install the product on a
defective installation stand.
• It may cause injury, accident, or
damage to the product.
Be cautious when unpacking
and installing the product.
• Sharp edges could cause injury.
Be especially careful of the case
edges and the fins on the
condenser and evaporator.
Be sure the installation area
does not deteriorate with age.
• If the base collapses, the air
conditioner could fall with it,
causing property damage,
product failure, and personal
injury.
■ Operation
Do not let the air conditioner run for a
long time when the humidity is very high
and a door or a window is left open.
• Moisture may condense and wet
or damage furniture.
Do not plug or unplug the
power supply plug during
operation.
• There is risk of fire or electric
shock.
Take care to ensure that power
cable could not be pulled out or
damaged during operation.
Do not place anything on the
power cable.
• There is risk of fire or electric
shock.
• There is risk of fire or electric
shock.
Do not touch(operate) the
product with wet hands.
Do not place a heater or
other appliances near the
power cable.
• There is risk of fire or electrical
shock.
• There is risk of fire and electric
shock.
4 Floor Standing-Type Air Conditioner
Safety Precautions
• It may cause There is risk of fire,
failure of the product, or electric
shock.
Do not store or use flammable
gas or combustibles near the
product.
• There is risk of fire or failure of
product.
Do not use the product in a
tightly closed space for a
long time.
• Oxygen deficiency could occur.
Gasolin
When flammable gas leaks,
turn off the gas and open a
window for ventilation
before turn the product on.
If strange sounds, or small or
smoke comes from product. Turn
the breaker off or disconnect the
power supply cable.
• Do not use the telephone or turn
switches on or off.
There is risk of explosion or fire
• There is risk of electric shock or
fire.
Do not open the inlet grill of the
product during operation.
(Do not touch the electrostatic
filter, if the unit is so equipped.)
When the product is soaked
(flooded or submerged),
contact an Authorized
Service Center.
• There is risk of physical injury,
electric shock, or product failure.
• There is risk of fire or electric
shock.
Ventilate the product from time to time when
operating it together with a stove, etc.
• There is risk of fire or electric shock.
Stop operation and close the window
in storm or hurricane. If possible,
remove the product from the window
before the hurricane arrives.
• There is risk of property damage,
failure of product, or electric shock.
Be cautious that water could
not enter the product.
• There is risk of fire, electric shock,
or product damage.
Turn the main power off when cleaning or
maintaining the product.
• There is risk of electric shock.
Owner's Manual 5
ENGLISHENGLISH
Do not allow water to run
into electric parts.
Safety Precautions
When the product is not be used for a long
time, disconnect the power supply plug or
turn off the breaker.
• There is risk of product damage or failure, or
unintended operation.
Take care to ensure that nobody could step
on or fall onto the outdoor unit.
• This could result in personal injury and product
damage.
CAUTION
■ Installation
Always check for gas
(refrigerant) leakage after
installation or repair of product.
• Low refrigerant levels may cause
failure of product.
Install the drain hose to
ensure that water is drained
away properly.
• A bad connection may cause
water leakage.
Keep level even when
installing the product.
• To avoid vibration or water
leakage.
90˚
Do not install the product where the
noise or hot air from the outdoor unit
could damage the neighborhoods.
• It may cause a problem for your
neighbors.
Use two or more people to
lift and transport the
product.
• Avoid personal injury.
Do not install the product where
it will be exposed to sea wind
(salt spray) directly.
• It may cause corrosion on the
product. Corrosion, particularly on
the condenser and evaporator fins,
could cause product malfunction or
inefficient operation.
■ Operation
Do not expose the skin directly to cool air for
long periods of time.
(Don't sit in the draft.)
• This could harm to your health.
6 Floor Standing-Type Air Conditioner
Do not use the product for special purposes, such as
preserving foods, works of art, etc. It is a consumer air
conditioner, not a precision refrigeration system.
• There is risk of
damage or
loss of property.
Safety Precautions
Use a soft cloth to clean. Do
not use harsh detergents,
solvents, etc.
• It may cause product failure.
• There is risk of fire, electric shock,
or damage to the plastic parts of
the product.
Do not touch the metal parts of
the product when removing the
air filter. They are very sharp!
• There is risk of personal injury.
x
Wa Thinner
Do not step on or put
anyting on the product.
(outdoor units)
Always insert the filter securely.
Clean the filter every two weeks
or more often if necessary.
Do not insert hands or other
objects through the air inlet or
outlet while the product is operated.
• There is risk of personal injury
and failure of product.
• A dirty filter reduces the efficiency
of the air conditioner and could
cause product malfunction or
damage.
• There are sharp and moving parts
that could cause personal injury.
Do not drink the water
drained from the product.
Use a firm stool or ladder
when cleaning or
maintaining the product.
• It is not sanitary and could cause
serious health issues.
• Be careful and avoid personal
injury.
Do not recharge or disassemble the batteries.
Do not dispose of batteries in a fire.
• They may burn or explode.
Replace the all batteries in the
remote control with new ones of
the same type. Do not mix old
and new batteries or different
types of batteries.
• There is risk of fire or explosion
If the liquid from the batteries gets onto your
skin or clothes, wash it well with clean water. Do
not use the remote if the batteries have leaked.
• The chemicals in batteries could cause burns or other
health hazards.
Owner's Manual 7
ENGLISHENGLISH
Do not block the inlet or
outlet of air flow.
Operating Instructions
Operating Instructions
Features and Specifications
1. Design for cooling and heating
5. 3 cooling/heating speeds
2. Super energy efficiency
6. Removable air filter
3. Micom control
7. 3 minutes delay circuit
4. Wireless remote control
8. Anti-Bacteria filter(A/CL Model)
Air Outlet Vent
Air Intake Vent
(Rear)
Remote Signal
Receptor
Air Outlet
Vent
Air Intake Vent
Piping
8 Floor Standing-Type Air Conditioner
Operating Instructions
Indoor Unit Controls and Indicators
1. START/STOP BUTTON
Operation starts when this button is pressed and
stops when the button is pressed again.
2. OPERATION MODE SELECTION
BUTTON
Used to select the operation Mode.
3. ROOM TEMPERATURE SETTING
BUTTONS
Used to select the room temperature.
4. INDOOR FAN SPEED SELECTION
Used to select fan speed in three steps-low, mid, hi.
5. FAN OPERATION LAMP
AIR CLEANER OPERATION LAMP
(AIR CLEANER MODEL ONLY)
6. COOLING OPERATION LAMP
7. SOFT DRY OPERATION LAMP
10 Floor Standing-Type Air Conditioner
8. HEATING OPERATION LAMP
9. DEFROST OPERATION LAMP
10. AUTO OPERATION LAMP
11. OFF TIMER OPERATION LAMP
12. OUTDOOR UNIT OPERATION LAMP
Wireless remote controller
Heat Pump
C/O model
Handling the remote control
11
Cooling only
Handing the remote control
Operating Instructions
ENGLISH
Remote control preparation
How to mount onto a wall
1 Use the screws to secure the holder to the
wall.
2 To insert the remote control to the holder.
- Do not use rechargeable batteries such batteries are different from standard dry cells in
shape, dimensions, and performance.
- Change the batteries with a new one if the
remote control does not work properly after
using for an extended period of time.
! CAUTION
How to insert batteries
1 Remove the cover from the back of the re-
mote controller.
- Slide the cover according to the arrow direction.
2 Insert two batteries.
• When not using remote controller for a
long time, flowing of dry cell liquid may
cause the failure of product, therefore,
remove all dry cells.
• When replacing dry cell (AAA), replace
two of them all with new ones, and if remote controller is not operated properly
even after replacing the dry cells (AAA),
request the service.
• Do not disassemble or re-charge the
used dry cells, and do not throw away
those at the location with heat of fire or
hot air. There will be the danger of explosion.
- Be sure that the (+) and (-) directions are
correct.
- Be sure that both batteries are new.
3 Re-attach the cover.
- Slide the cover into back position.
Owner's Manual 13
Operating Instructions
Cooling Mode
Airflow Setting
Up/Down Airflow Direction Control
Left/Right Airflow Direction Control
Heating Mode(Heat pump model)
Fan Speed Mode
Dehumidication Mode
Auto Operation Mode(C/O model)
Power Cooling
Simple Reservation
Turning ON reservation mode
Fan Mode
Turning OFF reservation mode
15
Operating Instructions
Child Lock Operation Procedure
1
Press the fan speed button and High temperature setting buttons simultaneously for 3 conds.
The unit will respond with beep.
After 3 second,
it will shift
2
During Child Lock Operation
3
For releasing child lock Operation
After 3 seconds,
it will shift
Whenever you press any Button on Display Panel, it will immediately display
“
”, which means Display panel is Locked.
All the Button on the indoor unit Display panel will not work.
But the Button on the remote controller will work.
Press the fan speed button and High temperature setting buttons simultaneously for 3 conds.
The unit will respond with beep, Child Lock Operation will removed.
After pressing
the buttons
it will shift
immediately
After 3 seconds,
it will shift
Auto restart
In case the power comes on again after a power failure, Auto Restarting Operation is the function to
operate procedures automatically to the previous operating conditions.
16 Floor Standing-Type Air Conditioner
Maintenance and Service
ENGLISH
Maintenance and Service
CAUTION: Before performing any maintenance, turn off the main power to the system.
During the season
Cleaning of the air filters.
Recommended about once every two weeks
Cleaning of the air cleaner.
Recommended about once every three months
Remove the Air Filter.
Take hold of the tab and pull slightly forward to
remove the filter.
Remove the Air Cleaner.
Take hold of the tab and pull slightly forward to
remove the air cleaner.
Clean.
噝 To remove the dust adhering to the filters, either use a
vacuum cleaner, or wash them in water and dry in the
shade.
噝 Re-insert the filter to the original position.
Clean.
噝 Dip the air cleaner into the water mixed with
detergent, for 20~30 minutes, and dry in the shade.
噝 Re-insert the air cleaner to the original position.
Never use any of the followings.
Cleaning of the air conditioner
噝 Water hotter than 40e&
Could cause deformation
and/or discoloration.
噝 Donÿ
t wash with water.
噝 Wipe with a soft dry cloth.
噝 Volatile substances.
Could damage the surfaces
of the air conditioner.
When the air conditioner is not going to be used for a long time.
At the start of the season
At the end of the season
Operate the air conditioner at the following
settings for 2 to 3 hours.
噝 Type of operation : Cooling.
噝 Temperature setting : 30°C.
This will dry out the internal mechanisms.
Remove the batteries from the Remote Control.
Turn off the circuit breaker.
Clean the air filters, re-insert, then operate
the air conditioner.
Be sure that nothing obstructs the air outlet
and intake vents.
&$87,21
Turn off the circuit breaker when the air conditioner
is not going to be used for a long time.
Dirt may collect and may cause a fire.
Operation Tips
Do not overcool the room.
Keep blinds or curtains closed.
Keep the room temperature uniform.
This is not good for your health and
wastes electricity.
Do not let direct sunshine enter the room
when the air conditioner is in operation.
Adjust the vertical and horizontal airflow
direction to ensure a uniform temperature
in the room.
Make sure that the doors and windows
are shut tight.
Clean the air filter regularly.
Ventilate the room occasionally.
Avoid opening doors and windows as
much as possible to keep the cool air in
the room.
Blockages in the air filter reduce the
airflow and lower cooling and
dehumidifying effects. Clean at least once
every two weeks.
Since windows are kept closed, it is a
good idea to open them and ventilate the
room now and then.
Owner's Manual 17
Maintenance and Service
Troubleshooting
Check the following points before requesting repairs or service.... If the malfunction persist, please contact your
dealer.
Case
Does not operate.
Explanation
See page
• Have you made a mistake in timer operation?
• Has the fuse blown or has the circuit breaker been
tripped?
• Is the power Switch at Off?
• Is the unit at the starting of Heating Operation?
If yes, Hot-start is activating.
• Is the unit in the Deicing?
If yes, wait for finishing the Deicing.
-
The room has a peculiar
odor.
• Check that this is not a damp smell exuded by the
walls, carpet, furniture, or cloth items in the room.
-
It seems that condensation is
leaking from the air
conditioner.
• Condensation occurs when the airflow from the air
conditioner cools the warm room air.
Air conditioner does not
operate for about 3 minutes
when restarted.
• This is the Protection device of the air conditioner .
• Wait about three minutes and operation will begin.
• If the airflow begins before its temperature become
warm, it will cause an undesired cooling effect. In
order to prevent this, the airflow will not begin until
it is sufficiently warm.
Does not cool effectively.
• Is the air filter dirty? See air filter cleaning
instructions.
• The room may have been very hot when the room
air conditioner was first turned on. Allow time for it
to cool down.
• Has the temperature been set incorrectly?
• Are the indoor unit's air inlet or outlet vents
obstructed?
-
• For a noise that sounds like water flowing.
-This is the sound of freon flowing inside the air
conditioner unit.
• For a noise that sounds like the compressed air
releasing into atmosphere.
-This is the sound of the dehumidifying water being
processed inside the air conditioning unit.
-
The air conditioner operation
is noisy.
Remote controller display is
faint, or no display at all.
-
-
-
• Are the batteries depleted?
• Are the batteries inserted in the opposite (+) and (-)
directions?
18 Floor Standing-Type Air Conditioner
1
www.lg.com
3.........
8 ........
23 ........
2
3
4
Gasolin
5
90˚
6
x
Wa Thinner
7
7&
6
1
7
2
8
3
4
5
8
A/CL
A/CL
: H/P
: C/O
‫تبريد فقط‬
‫‪1‬‬
‫رقم‬
‫‪5‬‬
‫‪2‬‬
‫‪١‬‬
‫‪4‬‬
‫‪6‬‬
‫‪3‬‬
‫‪٢‬‬
‫‪9‬‬
‫‪7‬‬
‫‪8‬‬
‫‪11‬‬
‫‪10‬‬
‫‪13‬‬
‫‪12‬‬
‫لوحة‬
‫التحكم‬
‫الوصف‬
‫مصباح تشغيل جھاز التحكم عن بعد‬
‫|‬
‫زر تشغيل‪ /‬إيقاف الطاقة‪ :‬سوف يبدأ التشغيل‬
‫عند الضغط على ھذا الزر‪ ،‬ويتوقف عند الضغط عليه‬
‫مرة أخرى‪.‬‬
‫‪٣‬‬
‫زر سرعة المروحة الداخلية‪ :‬لتحديد السرعة‬
‫المطلوبة للمروحة‪.‬‬
‫‪٤‬‬
‫زر ضبط درجة الحرارة‬
‫‪٥‬‬
‫‪A‬‬
‫زر التبريد‬
‫زر التنظيف التلقائي‬
‫‪٦‬‬
‫‪٧‬‬
‫‪D‬‬
‫زر إزالة الرطوبة‪ :‬يمكن إزالة الرطوبة بفعالية خالل‬
‫موسم األمطار أو الرطوبة العالية‪.‬‬
‫‪٨‬‬
‫‪C‬‬
‫زر التشغيل التلقائي‪ :‬عند تشغيل ھذه الوظيفة‪،‬‬
‫يتحكم تكييف الھواء في إعداد درجة الحرارة عن‬
‫طريق المقارنة بين درجة حرارة الغرفة ومستوى‬
‫التبريد أو التدفئة المضبوط من قبل العميل‬
‫‪٩‬‬
‫زر وضع المروحة‬
‫‪١٠‬‬
‫زر اتجاه تدفق الھواء )أعلى‪ /‬أسفل‪ ،‬يسار‪/‬‬
‫يمين( اضبط اتجاه تدفق الھواء رأسًيا أو أفقيًا‪.‬‬
‫‪١١‬‬
‫زر وضع التبريد القوي‪ :‬يشغل التبريد القوي‪.‬‬
‫‪١٢‬‬
‫زر إعداد مؤقت التشغيل‪ /‬اإليقاف‪ :‬اضبط وقت‬
‫بدء التشغيل أو اإليقاف‬
‫‪١٣‬‬
‫زر إلغاء المؤقت‬
‫التعامل مع جھاز التحكم عن بعد‬
‫ قم بتوجيھه نحو مستقبل اإلشارة في جھاز تكييف الھواء من نوع الحامل‬‫األرضي أثناء التشغيل‪.‬‬
‫ يمكن استقبال إشارة التحكم عن بعد على مسافة تصل إلى ‪ 7‬متر‬‫تقريًبا‪.‬‬
‫ تأكد من عدم وجود أي عوائق بين جھاز التحكم عن بعد ومستقبل‬‫اإلشارة‪.‬‬
‫ ال تقم بإفالت أو إلقاء جھاز التحكم عن بعد‪.‬‬‫ ال تضع جھاز التحكم عن بعد في مكان معرض لضوء الشمس المباشر‪ ،‬أو‬‫بالقرب من وحدة تدفئة‪ ،‬أو أي مصدر آخر للحرارة‪.‬‬
‫‪12‬‬
‫طريقة التركيب على الحائط‬
‫‪1‬‬
‫‪2‬‬
‫!‬
‫تنبيه‬
‫• في حال عدم استخدام جھاز التحكم عن بعد لفترة‬
‫طويلة‪ ،‬يمكن أن يتسبب سائل الخلية الجافة في‬
‫تعطل المنتج‪ ،‬وبالتالي يجب إزالة كل الخاليا الجافة‪.‬‬
‫طريقة إدخال البطاريات‬
‫‪1‬‬
‫‪2‬‬
‫‪3‬‬
‫‪13‬‬
‫ً‬
‫• عند استبدال الخلية الجافة )‪ ،(AAA‬استبدل اثنين‬
‫من العدد الكلي لھا بأخرى جديدة‪ ،‬وإذا لم يعمل‬
‫جھاز التحكم عن بعد بشكل مالئم حتى بعد‬
‫استبدال الخاليا الجافة )‪ ،(AAA‬اطلب الخدمة‪.‬‬
‫• ال تقم بتفكيك أو إعادة شحن الخاليا الجافة‬
‫المستخدمة‪ ،‬وال تتخلص منھا باإللقاء في به حرارة‬
‫منبعثة من الحريق أو ھواء ساخن‪ .‬سيؤدي ذلك إلى‬
‫خطر االنفجار‪.‬‬
1
1
2
2
3
3
22
1
2
2
1
1
40
30
2
2
3
23
,7 $ /,$ 12
1
-
-
-
-
-
-
12
24
Download PDF

advertising