LG | LVC-D204HM | LG LVC-D204HM Owner’s Manual

Operating Instructions
LVC-D200HM/HP/NM/NP
LVC-D202HM/HP/NM/NP
LVC-D204HM/HP/NM/NP
LVC-D201HM/HP/NM/NP
LVC-D203HM/HP/NM/NP
Before installing and using the camera,
please read these instructions thoroughly and retain them for later reference.
P/NO: 3834RS0068R
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
CAUTION TO REDUCE THE RISK OF
ELECTRIC SHOCK,
DO NOT REMOVE COVER (OR BACK).
NO USER SERVICEABLE PARTS
INSIDE,
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
This symbol is intended to alert
the user to the presence of
uninsulated “dangerous voltage”
within the product’s enclosure
that may be of sufficient
magnitude to constitute a risk
of electric shock to persons.
The exclamation point within an
equilateral triangle is intended
to alert the user to the presence
of important operating and
maintenance (servicing)
instructions in the literature
accompanying the product.
Warning
To prevent fire or shock hazard, do not expose
the unit to rain or moisture.
To avoid electrical shock, do not open
the cabinet Refer servicing to qualified
personnel only.
Wiring methods shall be in accordance with
the National Electric Code, ANSI/NFPA 70.
Regulatory Notices
For U.S.A
This equipment has been tested and found
to comply with the limits for a Class A digital
device, pursuant to Part 15 of the FCC
Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation! This
equipment generates, uses and can radiate
radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to
radio communications.
However, there is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception,
which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the interference by one
or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the
equipment and receiver.
• Connect the equipment into an outlet on a
circuit different from that to which the
receiver is connected.
• Consult the dealer or an experienced radio/TV
technician for help.
This Class A digital apparatus meets all
requirements of the Canadian InterferenceCausing Equipment Regulations.
This product is manufactured to comply with the radio interference
requirements of EEC DIRECTIVE 89/336/EEC, 93/68/EEC and
73/23/EEC.
1 Safety Precautions
Do not attempt to disassemble the camera
To prevent electric shock, do not remove
screws or covers. There are no user
serviceable parts inside. Ask a qualified
service personnel for servicing.
Do not use strong
solvents or detergents
Use a dry cloth to the camera when it is
dirty. If it is hard to remove the dirt on
the camera, use a mild detergent and
wipe it gently.
Before operating, please
check proper temperature,
humidity and power
source ratings.
Use the camera under conditions where
temperature is between -10°C ~ +50°C.
Do not expose the camera
in such conditions as
shown below.
Use in a room or area filled with cigarette smoke, dust or gas.
Avoid the camera with
direct sunlight
Do not aim the camera at bright objects.
Never face it with direct sunlight or other
extremely bright objects. Otherwise
blooming or smear may be caused.
Handle the camera
with care
Do not abuse the camera. Avoid striking,
shaking, etc. The camera could be damaged by improper handling or storage.
Do not expose the camera
to rain or moisture
This product is designed for indoor use or
location where it is protected from rain
and moisture. When exposed to moisture, turn the power off immediately and
ask a qualified service personnel for servicing. Moisture can damage the camera
and also create the danger of electric
shock.
2 What's in the box
Video Cable
Camera Body
M4 Tapping Screws
(2EA)
(Pan Lock Screw)
Optional
Adapter (DC 12V, 300mA)
3 Construction
Front View
LG logo
4-pin Dip Switch
Tilt Base
Focus Lock Screw
Side View
Dome Cover
Lens
Tilting Lock Screw
Dome Cover Separatory
Spring
4 Construction
Rear View
Dome Cover Separatory
Spring
Power In
Video Out
N.C
(Option: Ext. Sync.
or Audio)
GND
Pan Base
Base Fixing Hole
5 Installation
Video Cable Connection
RED Cable
BLACK Cable
WHITE Cable
1. RED : Connect the RED Cable to 1(+).
2. BLACK : Connect the BLACK Cable to 2(-).
3. WHITE : Connect the WHITE Cable to 3(V).
6 Installation
Camera Installation
1. Aim the LG logo of the Dome Camera to face the place that
you wish to watch.
2. Tighten the M4 Tapping Screws to fix the Dome Camera on
the ceiling, then adjust the Pan (Left / Right) by moving the
Pan Base. Tighten the M4 Tapping Screws after adjustment.
3. Loosen the Tilting Lock Screw. Adjust the Tilt (Up / Down) by
moving the Tilt Base then tighten Tilting Lock Screw.
4. Loosen the Focus Lock Screw. Adjust the Focus by moving
the Focus Lens then tighten Focus Lock Screw.
5. Install the Dome Cover to the main body by turning it counterclockwise to the end.
Pan Base
Hole for Fixing
Tilting Lock Screw
Tilt Base
M4 Tapping Screw
Focus Lock Screw
Dome Cover
7 Installation
NOTE
•
When you disassemble the Dome Cover, lift the Dome Cover
Separatory Spring on the opposite side of LG Logo and turn
the Dome Cover clockwise simultaneously.
Dome Cover
Separatory Spring
•
When you install the camera, handle with care. The camera
could be damaged by improper handling or storage.
•
If this camera is mounted on the other places except ceiling,
you need an extra bracket for mounting.(not supplied)
8 Installation
Camera Connection
Connect the Power Adapter (12V, 300mA; optional) to the Power
Input Jack of the camera as shown below.
Power
Input Jack
Adapter
Jack
Adapter
BNC
Rear Panel
Monitor
9 Setup
4-pin Dip Switch Setting
This camera has the 4-pin Dip Switch inside of the camera for
setting.
1. ABL : Auto BLC
The default setting is OFF.
2. BLC : Backlight Compensation
The default setting is OFF.
3. Y/DC IRIS : When you use Video Lens or DC IRIS Lens
The default setting of D200's is DC. (using the fixed lens)
4. ALC / ELC : ELC (Electronic IRIS), ALC (Auto IRIS)
The default setting of D200's is ELC.
OFF OFF DC
ELC
ABL BLC
ALC
Y
NOTE
No. 3 and 4 must be set as a default mode. Depending on the
conditions, No.1 and 2 are adjustable.
(Backlight Compensation : refer to the next page)
10 Setup
Backlight Compensation Setting
Backlight compensation eliminates strong background light
which makes the camera picture dark such as a spotlight. You
can select the mode for adjusting the iris lens. There are two
mode as follows.
1. BLC : Set the BLC to ON. The lens iris is manually fixed at
the value that you have set regardless of an object.
OFF OFF DC
ELC
ABL BLC
ALC
Y
2. ABL : Set the ABL to ON. The lens iris is automatically
adjusted according to the brightness of an object.
OFF OFF DC
ELC
ABL BLC
ALC
Y
11 Troubleshooting
Check the following guide for the possible cause of a problem
before contacting service.
•
The picture is poor
Does the Dome Cover have lots of dust on the surface?
Use a dry cloth to clean the camera when it is dirty.
Smear may be caused to the screen of night than daytime.
Adjust the Focus by moving the Focus Lens.
•
Contrast of the screen is not clear.
Check the condition of the monitor.
Alight source such as a spot light causes burn-in on the
display screen. Adjust position or angle of the camera to
eliminate strong background light.
•
Background screen appears white extremely.
You can set the background compensation to OFF.
12 Dimension
ø100
76.5mm
26.5mm
ø
90
ø120
13 Specifications (1)
Model
Signal System
Total / Effective Pixels
Pick-Up Device
Lens
Angular Field of View (D)
Focus
Signal Process
Scanning System
Sync. System
Scanning Frequency
Resolution
S/N Ratio
Standard Illuminance
Sensitivity (1/3 output)
Video Output Signal
Gain Control
Shutter Speed
White Balance
Back Light
Power Source
Power Consumption
Operating Temp.
Storage Temp.
Weight
Dimensions
LVC-D200HM
LVC-D200HP
NTSC
PAL
410K/380K
470K/440K
1/3-Inch Interline Color CCD (Super HAD)
Fixed Lens (f=3.0mm/F=2.0, f=3.7mm/F=2.0 * 1)
/ f=6.0mm/F=1.8, f=8mm/F=2.5, f=12mm/F=2.5)
115°(f=3.0mm), 92°(f=3.7mm), 54°(f=6mm),
38.6°(f=8mm), 25.7°(f=12mm)
Manual
Digital Signal Process
2 : 1 Interlace
Internal
59.94 Hz(VD)
50Hz(VD)
480 Line (H)
470 Line (H)
More than 48dB
2000Lux (3200 ° K)
0.5 Lux (F1.2)
1Vp-p Composite (75Ω)
Auto
Electronic Shutter
Electronic Shutter
(1/60 ~ 1/10000)
(1/50 ~ 1/10000)
Auto
Compensation ON/OFF, AUTO
DC12V
2.3W
-10°C ~ 50°C (Humidity : 0%RH ~ 60RH)
-20°C ~ 60°C (Humidity : 0%RH ~ 85RH)
182g
ø120 (Diameter)x76.5(H), Dome Size=ø100
*1) LVC-D200'S (3mm) / LVC-D201'S (6mm) / LVC-D202'S (12mm)
LVC-D203'S (8mm) / LVC-D204'S (3.7mm)
Design and specifications are subject to change without notice.
14 Specifications (2)
Model
Signal System
Total / Effective Pixels
Pick-Up Device
Lens
Angular Field of View(D)
Focus
Signal Process
Scanning System
Sync. System
Scanning Frequency
Resolution
S/N Ratio
Standard Illuminance
Sensitivity (1/3 output)
Video Output Signal
Gain Control
Shutter Speed
White Balance
Back Light
Power Source
Power Consumption
Operating Temp.
Storage Temp.
Weight
Dimensions
LVC-D200NM
LVC-D200NP
NTSC
PAL
270K/250K
320K/290K
1/3-Inch Interline Color CCD (Super HAD)
Fixed Lens (f=3.0mm/F=2.0, f=3.7mm/F=2.0 *1)
/ f=6.0mm/F=1.8, f=8mm/F=2.5, f=12mm/F=2.5)
115°(f=3.0mm), 92°(f=3.7mm), 54°(f=6mm),
38.6°(f=8mm), 25.7°(f=12mm)
Manual
Digital Signal Process
2 : 1 Interlace
Internal
59.94 Hz(VD)
50Hz(VD)
330 Line (H)
320 Line (H)
More than 48dB
2000Lux (3200 ° K)
0.1 Lux (F1.2)
1Vp-p Composite (75Ω)
Auto
Electronic Shutter
Electronic Shutter
(1/60 ~1/10000)
(1/50 ~1/10000)
Auto
Compensation ON / OFF, AUTO
DC12V
2.3W
-10°C ~ 50°C (Humidity : 0%RH ~ 60RH)
-20°C ~ 60°C (Humidity : 0%RH ~ 85RH)
182g
ø120 (Diameter)x76.5(H), Dome Size=ø100
*1) LVC-D200'S (3mm) / LVC-D201'S (6mm) / LVC-D202'S (12mm)
LVC-D203'S (8mm) / LVC-D204'S (3.7mm)
Design and specifications are subject to change without notice.
Download PDF

advertising