LG | LW-C1269CL | LG LW-C1269CL Owner’s Manual

ROOM AIR CONDITIONER
OWNER'S MANUAL
?
?
?
Please read the operating instructions and safety
precautions carefully and thoroughly before installing
and operating your room air conditioner.
The appliance is not intended for use
or infirm persons without supervision.
Young
do not
by young
children should be supervised to
play with the appliance.
ensure
children
that
they
Prior to installation, this air-conditioning unit must be
submitted for approval by the utility service which
provides eletricity(EN 60555-3 Norm).
TABLE OF CONTENTS
FEATURES
...........................................................................................................
OPERATING
.........................................................................................................
2
3
VENTILATION................................................................................................... 3
DISPLAY
...........................................................................................................
REMOTE CONTROL
........................................................................................
HOW TO INSERT BATTERIES
........................................................................
3
4
4
TO CONTROL AIR DIRECTION....................................................................... 5
HOW TO DRAIN
..............................................................................................
AIR FILTER CLEANING
...................................................................................
INSTALLATION INSTRUCTIONS
BEFORE REQUESTING SERVICE
.....................................................................
.....................................................................
FEATURES
30˚C
12H
20˚C
2H
1. CABINET
8. CONTROL BOARD
2. VERTICAL LOUVER
(HORIZONTAL
AIR
9. POWER CORD
DEFLECTOR)
10. EVAPORATOR
3. HORIZONTAL LOUVER
(VERTICAL
AIR
11. CONDENSER
DEFLECTOR)
12. COMPRESSOR
4. AIR DISCHARGE
13. BASE PAN
5. FRONT GRILLE
6. INLET GRILLE
14. BRACE
(AIR INTAKE)
15. REMOTE CONTROLLER
7. AIR FILTER
-2-
5
5
6
7
OPERATING
?
CAUTION
-
When the air conditioner has been
fan
-
performing its cooling operation and is turned off or
resetting to the cooling operation again.
set to the
wait at least 3 minutes before
operation,
Please, set auto restart switch to "OFF" mode when you go out.
VENTILATION
The ventilation lever must be in the CLOSE
position
in order to maintain the best
cooling
conditions.
When fresh air is necessary in the room, set the ventilation lever to the OPEN
The damper is opened and room air is exhausted.
position.
Part
Part
CLOSE
VENT
NOTE: Before
make
part
a
£
using
£
£
OPEN
the ventilation feature,
pull down
ventilation kit. First,
to horizontal line with
part
£
.
DISPLAY
?
?
12H
30˚C
SIGNAL RECEPTOR
OPERATION SWITCH
When you cannot using Remote Controller,
push this button.
When you first turn on, the Set is on the High
Cool mode and the Temp. of 22°C. When
you
2H
20˚C
?
push this button again, the set is OFF.
DISPLAY COOL/FAN
It indicates COOL/FAN.
?
TEMPERATURE SETTING LAMP.
You
can
regulate
room
most comfortable
?
temperature
at your
30˚C
degrees by turns.
FAN
TIMER
It
displays
12H
the
operating
of timer.
20˚C
COOL
-3-
TEMP
2H
TIMER
POWER
REMOTE CONTROL
Precaution: The Remote Controller will not operate properly if strong light strikes the sensor window of
or if there are obstacles between the Remote Controller and the air conditioner.
the air conditioner
TIMER
?
Everytime you push
4Hours
(2Hours
this button, timer is set
6Hours....
as
follows.
12Hours)
COOL/FAN
?
?
Everytime you push
only by turns.
this button, it will be COOL and FAN
When you first turn on, it set the COOL mode.
POWER
?
?
To turn the Set ON, push the button. To turn the Set OFF,
push the button, again.
This button has
priority
to any other buttons.
TEMPERATURE SETTING
?
This button
automatically
can
temperature of the
control the
The temperature can be set within
a range of 20°C to 30°C by 2°C.
Select the lower number for lower temperature of the room.
room.
FAN SPEED
?
Everytime you push this button,
Low
(High
High ...)
it is set
?
When you first turn on, it set the
High
as
follows.
mode.
HOW TO INSERT BATTERIES
1
Remove the
Slide the
cover
according
?
Be
sure
that the
directions
Be
sure
to the arrow direction.
rechargeable
differ from standard
(+)
and
dry
cells in
shape,
performance.
(-)
correct.
?
are new.
Remove the batteries from the
remote controller if the air
conditioner is not
cover.
Slide it back into
use
dimensions, and
that both batteries
Re-attach the
?
are
Do not
batteries such batteries
Insert two battaries.
?
3
from the back of the remote
?
?
2
cover
controller.
used for
position.
-4-
an
going to be
length of
extended
TO CONTROL AIR DIRECTION
The direction of air
can
be controlled wherever you want to cool
by adjusting
the horizontal louver and
the vertical louver.
?
HORIZONTAL AIR-DIRECTION CONTROL
The horizontal air direction is
rotating
adjusted by
right or left.
the vertical louver
12H
?
VERTICAL AIR-DIRECTION CONTROL
The vertical air direction is
adjusted by rotating
the horizontal louver forward
or
backward.
12H
30˚C
2H
20C
HOW TO DRAIN
DRAIN
First, be
PIPE
installation.
sure
to insert the drain
pipe
into base pan before
The air conditioner must be installed with
for proper water
BASE PAN
a
slight
tilt to the outside
drainage.
Generally the air conditioner
pipe.(See description)
may drain condensation
through
drain
AIR FILTER CLEANING
The air filter should be checked at least twice
a
month to
causes
1.
4.
if
cleaning
the inlet
is necessary. Trapped
cooling capacity and also
grille upward by pulling out the bottom of the inlet grille.
grille assembly by pulling the air filter up slightly.
Wash the filter using lukewarm water below 40°C(104°F).
Gently shake the excess water from the filter completely. Replace the filter.
Open
2. Remove the air filter from the front
3.
see
in the filter will build up and block the airflow. This reduces the
an accumulation of frost on the cooling coils.
particles
-5-
the
INSTALLATION INSTRUCTIONS
Shipping
1. Remove the
screws
screws
which fasten the cabinet
at both sides and at the back.
30˚C
12H
20˚C
2H
2. Slide the unit from the cabinet
base pan handle and
bracing
pulling
by gripping
the
forward while
the cabinet.
30˚C
12H
20˚C
2H
3. Remove EPS Material.
EPS Material
30˚C
12H
20˚C
2H
4. Slide the unit into the cabinet.
CAUTION: For
security purpose,
reinstall
screw
at cabinet's sides.
30˚C
12H
20˚C
Power cord
2H
Screw
Screw
-6-
5. Attach the front
inserting
to the cabinet
grille
the tabs
on
the
grille
the fornt of the cabinet. Push the
it snaps into
6. Lift the inlet
through
by
into the tabs
grille
on
in until
place.
grille
the front
and
secure
it with
a screw
grille.
BEFORE REQUESTING SERVICE
?
Air Conditioner will not
operate.
plugged into the outlet?
fuse or breaker good?
voltage unusually high or low?
1. Is the air conditioner
2. Is the
3. Is the
?
Air from the unit does not feel cold
enough
on
the
cooling setting.
setting temperature correct?
2. Is the air filter clogged with dust?
1. Is the
3. Is the air flow from the
Leave
or
a
clearance of
outside(condensers) obstructed?
1 meter(3.28 feet) between the
over
back of the air conditioner and the wall
fence behind it.
or windows open, or is there any source of heat in the room?
NOTE: If it is difficult to find out the cause of the trouble, be sure to turn the air conditioner off and
contact the dealer.
4. Are the door
?
OFF-SEASON MAINTENANCE
1. Clean the air filter and re-install.
2. Turn the power off
?
OPERATING
by operation knob,
and disconnect the power
TEMPERATURE(°C)
INSIDE
OUTSIDE
MAX
MIN
MAX
MIN
32
21
43
21
-7-
plug
from the wall
receptacle.
P/NO.
:
3828AR3222P
Printed in Korea
Download PDF