LG | PQRCHCA0QW.ENCXLUS | LG PQRCHCA0QW.ENCXLUS Owner’s Manual

ENGLISH ITALIANO ESPAÑOL FRANÇAIS DEUTSCH PORTUGUESE РУССКИЙ ЯЗЫК
OWNER’S &
INSTALLATION MANUAL
AIR
CONDITIONER
Please read this manual carefully before operating
your set and retain it for future reference.
SIMPLE WIRED REMOTE CONTROLLER
PQRCHCA0Q
PQRCHCA0QW
www.lg.com
P/NO : MFL62862003
2
TIPS FOR SAVING ENERGY
ENGLISH
TIPS FOR SAVING ENERGY
Here are some tips that will help you minimize the power consumption when you use the air
conditioner. You can use your air conditioner more efficiently by referring to the instructions
below:
• Do not cool excessively indoors. This may be harmful for your health and may consume
more electricity.
• Block sunlight with blinds or curtains while you are operating the air conditioner.
• Keep doors or windows closed tightly while you are operating the air conditioner.
• Adjust the direction of the air flow vertically or horizontally to circulate indoor air.
• Speed up the fan to cool or warm indoor air quickly, in a short period of time.
• Open windows regularly for ventilation as the indoor air quality may deteriorate if the air conditioner is used for many hours.
• Clean the air filter once every 2 weeks. Dust and impurities collected in the air filter may
block the air flow or weaken the cooling / dehumidifying functions.
For your records
Staple your receipt to this page in case you need it to prove the date of purchase or for warranty
purposes. Write the model number and the serial number here:
Model number :
Serial number :
You can find them on a label on the side of each unit.
Dealer’s name :
Date of purchase :
IMPORTANT SAFETY INSTRUCTIONS
3
READ ALL INSTRUCTIONS BEFORE USING THE APPLIANCE.
Always comply with the following precautions to avoid dangerous situations and ensure peak
performance of your product
! WARNING
It can result in serious injury or death when the directions are ignored
! CAUTION
It can result in minor injury or product damage when the directions are ignored
! WARNING
• Installation or repairs made by unqualified persons can result in hazards to you and others.
• Installation MUST conform with local building codes or, in the absence of local codes, with
the Nation Electrical Code NFPA 70/ANSI C1-1003 or current edition and Canadian Electrical
Code Part1 CSA C.22.1.
• The information contained in the manual is intended for use by a qualified service technician
familiar with safety procedures and equipped with the proper tools and test instruments.
• Failure to carefully read and follow all instructions in this manual can result in equipment malfunction, property damage, personal injury and/or death.
Installation
• Be sure to request to the service center or installation specialty store when installing products.
- It will cause fire or electric shock or explosion or injury.
• Request to the service center or installation specialty store when reinstalling the installed
product.
- It will cause fire or electric shock or explosion or injury.
• Do not disassemble, fix, and modify products randomly.
- It will cause fire or electric shock.
Operation
• Do not place flammable stuffs close to the product.
- It will cause fire.
• Do not allow water to run into the product.
- It will cause electric shock or breakdown.
• Do not give the shock to the product.
- It will cause breakdown when giving the shock to the product.
• Request to the service center or installation specialty store when the product becomes wet.
- It will cause fire or electric shock.
• Do not give the shock using sharp and pointed objects.
- It will cause breakdown by damaging part.
ENGLISH
IMPORTANT SAFETY INSTRUCTIONS
4
IMPORTANT SAFETY INSTRUCTIONS
ENGLISH
! CAUTION
• Do not clean using the powerful detergent like solvent but use soft cloths.
- It will cause fire or product deformation.
• Do not press the screen using powerful pressure or select two buttons.
- It will cause product breakdown or malfunction.
• Do not touch or pull the lead wire with wet hands.
- It will cause product breakdown or electric shock.
TABLE OF CONTENTS
ENGLISH
TABLE OF CONTENTS
2
TIPS FOR SAVING
ENERGY
3
IMPORTANT SAFETY INSTRUCTIONS
6
PART DESCRIPTION
6
6
Using the remote control
Accessory
7
INSTALLATION INSTRUCTION
9
10
11
11
12
13
13
14
14
15
15
16
Remote controller installation
Group Control
Install Setting
- How to enter installer setting mode
- Installer Setting Code Table
- Test Run Mode
- Setting Address of Central control
- E.S.P
- Thermistor
- Ceiling Height Selection
- Static Pressure Setting
- Remote Controller Master/Slave Setting
5
16
- Fahrenheit Switching
17 OWNER'S INSTRUCTION
17
17
17
17
17
17
18
18
18
18
Standard Operation
- Cooling Mode
- Heating Mode
- Auto Operation Mode
- Dehumidification Mode
- Fan Mode
Function setting
- Fan Speed Selection
- Room Temperature Check
- Child Lock
6
PART DESCRIPTION
ENGLISH
PART DESCRIPTION
Using the remote control
Display screen
FAN
SPEED
Control button
TEMP
ROOM
TEMP
Control
panel
Display screen
18~30°C
Description
Temperature adjustment button: Adjusts the room temperature when
cooling and heating.
Indoor fan speed button: Adjusts the fan speed.
On/Off button: Turns the power on/off.
Displays the room temperature. Ex)
Accessory
Connection Cable
(1EA, 10m)
Screw
(2 EA)
Owner's / Installation
manual
INSTALLATION INSTRUCTION
7
ENGLISH
INSTALLATION INSTRUCTION
1 Please fix tightly using provided screw
after placing remote controller setup board
on the place where you like to setup.
- Please set it up not to bend because poor
setup could take place if setup board
bends.
Please set up remote controller board fit
to the reclamation box if there is a reclamation box.
3 Please fix remote controller upper part into
the backplate attached to the surface of
the wall, as the picture below, and then,
connect with backplate by pressing lower
part.
- Please make sure to leave no gaps on
the top, bottom, left or right sides between the remote controller and backplate.
- Before assembly with the backplate,
arrange the Cable not to interfere with
circuit parts.
<Connecting order>
Wall
Side
2 Can set up Wired remote controller cable
into three directions.
- Setup direction: the surface of wall reclamation, upper, right
- If setting up remote controller cable into
upper and right side, please set up after
removing remote controller cable guide
groove.
h Remove guide groove with long nose.
① Reclamation to the surface of the wall
② Upper part guide groove
③ Right part guide groove
<Wire guide grooves>
Wall
Side
Remove remote controller by inserting a
screwdriver into the lower separating
holes and twisting to release the controller
from backplate.
- There are two separating holes. Please
individually separate one at a time.
- Please be careful not to damage the inside
components when separating.
<Separating order>
Wall
Side
Wall
Side
8
INSTALLATION INSTRUCTION
ENGLISH
4 Please refer to the following directions
when connecting the indoor unit and the
wired remote controller together.
1) Please connect the cables as shown in the
figure below when connecting the plug
type cable from the indoor unit’s C/BOX
and the housing type of the extension
cable.
Please check if connector
is normally connected.
C/BOX Cable (Plug type)
Indoor
Unit
side
Connecting
cable
FAN
SPEED
TEMP
ROOM
TEMP
Signal
12V
GND
Yellow
Red
Black
! CAUTION
Remote
controller PCB
Indoor
unit side
YELLOW RED BLACK
Signal 12V GND
Specification of LG supplied extension
cable: AWG#22, 3 core shielded. (Model :
PZCWRC1)
* Apply enclosed noncombustible conduit(metal raceway) totally or use FT-6
rated cable or above level in case of
local electric & building code that requires plenum (CMP) cable usage.
2) When connecting Terminal Blocks of the indoor C/BOX and the wired remote controller with the extension cable, refer to the
steps below.
① Remove the screw on the cable which is
fastened to the wired remote controller’s
Terminal Block by loosening with a screw
driver.
② Remove the housing of the provided 32ft
extension cable with a cutting nipper and
peel it as shown in the figure below. (when
purchasing the extension cable at the site
directly, please peel it as shown in the figure below.)
)
mm
(35 m)
inch ch(5m
8
7
1.3 .197 in
±0
③ Make sure each wire is securely fastened
under each screw terminal and the wires
are not in contact with each other.
④ Please connect the Terminal blocks of indoor unit’s C/BOX and wired remote controller by referring to the images and
contents shown below.
Connect the yellow(signal) part of the wired
remote controller’s terminal block and the
‘YL’ part of the indoor unit’s terminal block.
Connect the red(12V) part of the wired remote controller’s terminal block and the
‘RD’ part of the indoor unit’s terminal block.
Connect the black(GND) part of the wired
remote controller’s terminal block and the
‘BK’ part of the indoor unit’s terminal block.
0.394 inch(10mm) ± 0.118 inch(3mm)
<Remote controller>
<Indoor Terminal Block>
Remote controller
Indoor TerPCB Terminal block
minal block
Remark
Function
YELLOW
YL
RED
RD
Signal
12V
BLACK
BK
GND
* In case of loosened screws or insufficient
contact between the terminal and the wire,
remote controller may not function properly.
* When the power is off on the remote controller, check the connection between the
remote controller and Terminal Block.
* Use an appropriate screwdriver for tightening the terminal screws. A screwdriver with
a small head will strip the head and make
proper tightening impossible.
* Over-tightening the terminal screws may
break wires and terminal block structure.
INSTALLATION INSTRUCTION
• Installation work must be performed in
accordance with the national wiring standards and local by
authorized personnel only.
• Installations must comply with the applicable local/national or international standards.
• AWG#22, 3 core shielded is recommended when using the large hole in the
center of the back plate.
• AWG#24, 3 core shielded is recommended when using the side or top
knock-out of the back plate.
5 Please use an extension cable if the distance between the wired remote controller
and the indoor unit is longer than
32ft(10m).
! CAUTION
When installing the wired remote controller, do not bury it in the wall. (It can
cause damage in the temperature sensor.)
Do not install the cable to be 164ft(50m) or
longer. (It can cause communication error.)
Remote controller installation
Since the room temperature sensor is in the
remote controller, the remote controller box
should be installed in a place away from direct
sunlight, high humidity and direct supply of
cold air to maintain proper space temperature.
Install the remote controller about 5ft(1.5m)
above the floor in an area with good air circulation at an average temperature.
Do not install the remote controller where it
can be affected by:
- Drafts, or dead spots behind doors and in
corners.
- Hot or cold air from ducts.
- Radiant heat from sun or appliances.
- Concealed pipes and chimneys.
- Uncontrolled areas such as an outside wall
behind the remote controller.
- This remote controller is equipped with LCD.
display. For proper display of the remote controller LCD's, the remote controller should be
installed properly as shown in Fig.1.
(The standard height is 4~5 ft (1.2~1.5 m)
from floor level.)
Direct
Sun ray contact area
yes
FAN
SPEED
TEMP
OPER
MODE
no
FAN
SPEED
TEMP
OPER
MODE
FAN
SPEED
TEMP
OPER
MODE
FAN
SPEED
TEMP
OPER
MODE
5feet
(1.5meters)
no
(Fig. 1)
no
ENGLISH
! CAUTION
9
10 INSTALLATION INSTRUCTION
ENGLISH
Group Control
GND
Signal wire
12V
GND Signal wire
FAN
SPEED
TEMP
ROOM
TEMP
1 When installing more than 2 units of air
conditioner to one wired remote controller,
please connect as the right figure.
- If it is not event communication indoor
unit, set the unit as slave.
- Check for event communication through
the product manual.
2 When installing more than 2 wired remote
controllers to one air conditioner, please
connect as the right picture.
- When installing more than 2 units of
wired remote controller to one air conditioner, set one wired remote controller as
master and the others all as slaves, as
shown in the right picture.
- You cannot control the group as shown in
the right for some products.
- Refer to the product manual for more detail. When controlling multiple indoor
units with event communication function
with one remote controller, you must
change the master/slave setting from the
indoor unit.
- For ceiling type cassette and duct product group, change the switch setting of
the indoor PCB.
ON
1 2 3 4 5 6 7 8
#3 switch OFF: Master
(Factory default setting)
ON
1 2 3 4 5 6 7 8
#3 switch ON: Slave
- For wall-mount type and stand type product, change the master/slave setting with
the wireless remote controller. (Refer to
wireless remote controller manual for detail)
h When installing 2 remote controllers to
one indoor unit with event communication function, set the master/slave of
the remote controller. (Refer to remote
controller master/slave selection)
When controlling the group, some functions excluding basic operation setting,
fan level
Min/Mid/Max, remote controller lock
setting and time setting may be limited.
3 When installing more than 2 wired remote
controllers to one air conditioner, please
connect as the right picture.
GND
Signal wire
12V
B Y R
GND
Signal wire
12V
B Y R
FAN
SPEED
FAN
SPEED
TEMP
TEMP
ROOM
TEMP
MASTER
ROOM
TEMP
SLAVE
- When installing more than 2 units of
wired remote controller to one air conditioner, set one wired remote controller as
master and the others all as slaves, as
shown in the right picture.
- You cannot control the group as shown in
the right for some products.
- Refer to the product manual for more detail.
- When controlling in groups, set the
master/slave of the remote controller.
Refer to Installer setting section on how
to set master/slave for more detail.
INSTALLATION INSTRUCTION
1 If you want to set installer setting mode,
How to enter installer setting mode
! CAUTION
• Installer setting mode is to set the detail function of the remote controller.
If the installer setting mode is not set
correctly, it can cause problems to the
product, user injury or property damage. This must be set by an certificated
installer, and any installation or change
that is carried out by a non-certificated
person should be responsible for the results. In this case, free service cannot
be provided.
FAN
SPEED
TEMP
ROOM
TEMP
Press the Temperature up button and the
Room Temp button same time for five seconds.
2 When you enter the setting mode Initially.
Function code is displayed on the LCD
screen.
Function Code
Value
- Some categories of the menu may not
be displayed according to the function
of the product, or the menu name may
be different.
ENGLISH
Install Setting
11
12 INSTALLATION INSTRUCTION
ENGLISH
<Installer Setting Code Table>
1 General air-conditioner product
No.
1
2
3
4
Function
Test Run
Address Setting
E.S.P. Value
Thermistor
Code
01
02
03
Value
01:Set
00~FF : Address
<ESP Step>
01:VeryLow
02:Low
03:Med
04:High
05:Very High
04
01:Remo
02:Indoor
03:2TH
5
Ceiling Height
05
01:Med
02:Low
03:High
04:Very High
6
Static Pressure
06
01:V-H
02:F-H
03:V-L
04:F-L
7
Master Setting
07
8
Celsius Fahrenheit
Switching
12
00:Slave
01:Master
00:Celsius
01:Fahrenheit
<ESP Value>
0 ~ 255
<Example>
Function Code
ESP step
(Optimized only for U.S.A)
j Some contents may not be displayed depending on the product function
ESP value
INSTALLATION INSTRUCTION 13
Setting Address of Central control
After installing the product, you must a test
Run Mode. For details related to the Product
manual.
It’s the functional to use connecting central
control.
1 Press
1 Press
button and
button simultaneously for more than 3 seconds.
button and
button simultaneously for more than 3 seconds.
2 Setup function code ’02’ pressing by
button.
2 Setup figure ’01’ blinks
Function Code
Function Code
Value
Value
3 Press
3 Set group number and indoor number.
Group number
button to start.
TEMP
Control button
4 Press
button to save.
5 Press
button and
button simultaneously for more than 3 seconds After the
setting has been completed.
4 During the test run, pressing the below
button will exit run.
!
NOTE
• After setup, it automatically gets out of
setup mode if there is no button input
for 25seconds.
• When existing without pressing set button, the manipulated isn’t reflected.
ENGLISH
Test Run Mode
14 INSTALLATION INSTRUCTION
ENGLISH
E.S.P
Thermistor
This is the functional that decides the strenth
of the wind for each wind level and because
this function is to make the installation easier.
- If you set ESP incorrectly, the air conditional
may malfunction.
- This setting must be carried out by a certificated technician.
This is the function to select the temprature
sensor to judge the room temperature.
1 Press
button and
button simultaneously for more than 3 seconds.
2 Setup function code ’04’ pressing by
button.
1 Press
button and
button simultaneously for more than 3 seconds.
2 Setup function code ’03’ pressing by
Function Code
button.
ESP step
3 Set Thermistor value by pressing button by
Function Code
pressing temperature button.
(01: Remote Controller, 02: Indoor, 03: 2TH)
Value
3 Select ESP fan step and ESP value.
ESP Value
TEMP
ESP step
Thermistor value
4 Press
button to save.
* ESP value range : 0~255
5 Press
4 Press
button to save.
5 Press
button and
button simultaneously for more than 3 seconds After the
setting has been completed.
!
NOTE
• When setting ESP value on the product
without very weak wind or power wind
function, it may not work.
• Please be careful not to change the ESP
value for each fan step.
• It does not work to setup ESP value for
very low/power step for some product.
• ESP value is available for specific range
belongs to the product.
button and
button simultaneously for more than 3 seconds After the
setting has been completed.
!
NOTE
h The function of 2TH has difference operation characterics according to product.
• Cooling: Operation of higher temperature by comparing indoor unit’s and
wired remote controller’s temperature.
(there are products that operate at a
lower temperature.)
• Heating: Operation of lower temperature
by comparing indoor unit’s and wired remote controller’s temperature.
INSTALLATION INSTRUCTION 15
This function is to adjust FAN Airflow rate according to ceiling height (For ceiling type product)
Static Pressure Setting
This function is applied to only duct type. Setting this in cases will cause malfunction.
1 Press
1 Press
button and
button simultaneously for more than 3 seconds.
button and
button simultaneously for more than 3 seconds.
2 Setup function code ’06’ pressing by
2 Setup function code ’05’ pressing by
button.
button.
Function Code
Function Code
Value
3 Set Thermistor value by pressing button by
3 Set Thermistor value by pressing button by
pressing temperature button.
(01: Remote Controller, 02: Indoor, 03:
2TH)
pressing temperature button.
(01: V-H, 02: F-H, 03: V-L, 04:F-L)
Pressure
selection
Thermistor value
4 Press
button to save.
5 Press
button and
button simultaneously for more than 3 seconds After the
setting has been completed.
!
NOTE
• Ceiling height setting is available only for
some products.
• Ceiling height of “Very high” function
may not exist depending on the indoor
units.
• Refer to the product manual for more
details.
01
V-H
02
03
04
4 Press
5 Press
Function
ESP
Zone
standard
state
value
Variable
High
F-H
Fixed
High
V-L
Variable
Low
F-L
Fixed
Low
button to save.
button and
button simultaneously for more than 3 seconds After the
setting has been completed.
ENGLISH
Ceiling Height Selection
16 INSTALLATION INSTRUCTION
ENGLISH
Remote Controller Master/Slave
Setting
Fahrenheit Switching
It’s a function for setting in group control, or 2remote controller control.
This function is used for switching the display
between Celsius and Fahrenheit.
(Optimized only for U.S.A)
1 Press
1 Press
2 Setup function code ’07’ pressing by
2 Setup function code ’12’ pressing by
button and
button simultaneously for more than 3 seconds.
button.
button and
button simultaneously for more than 3 seconds.
button.
Function Code
Function Code
3 Select Master/Slave by pressing temperature button. (00: Slave, 01: Master)
3 Select Temperature unit mode by temperature button.
(00: Celsius , 02: Fahrenheit)
Master/Slave Value
4 Press
Fahrenheit setting
value
button to save.
5 Press
button and
button simultaneously for more than 3 seconds After the
setting has been completed.
4 Press
button to save.
5 Press
Remote
Controller
Function
Master
Indoor unit operates based on
master remote controller at
group control. (master is set
when delivering from the warehouse.)
Slave
Setup all remote controllers except one master remote controller to slave at group control.
- Refer to eh ‘Group control’ part for details.
• When controlling in groups, basic operation
settings, airflow strength
weak/medium/strong, lock setting of the remote controller, time settings, and other
functions may be restricted.
button and
button simultaneously for more than 3 seconds After the
setting has been completed.
h Whenever press
button in Fahrenheit mode, the temperature will
increase/drop 2 degrees.
OWNER'S INSTRUCTION 17
ENGLISH
OWNER'S INSTRUCTION
Standard Operation
1 Press the
button.
h The operation mode can be set from Central Controller only.
Cooling Mode
It cools the room by comfortable and Clean
wind.
1 Press the
button.
2 When the room temperature is lower than
the desired temperature
: Heating Operation starts (For Heat Pump
models only)
When the room temperature is higher than
the desired temperature
: Cooling Operation starts
Dehumidification Mode
2 Adjust the desired temperature by press
the temperature button.
(Temp range : 18°C~30°C (64°F~86°F)
It removes humidity while air-cooling Weakly.
1 Press the
button.
Heating Mode
It supplies warm wind to the indoor.
1 Press the
button.
Fan Mode
It blows the air as it is in the indoor, not the
cold wind.
2 Adjust the desired temperature by press
the temperature button.
(Temp range : 16°C~30°C (60°F~86°F)
1 Press the
button.
Auto Operation Mode
It makes the room cool using pleasant and
fresh air quickly
h Temperature control is not available during
the Dehumidification & Fan operation.
18 OWNER'S INSTRUCTION
ENGLISH
Function setting
Fan Speed Selection
Room Temperature Check
1 Press the
button.
You can easily control the fan speed.
1 Press the
button.
2 Press the
button.
Fan Speed Selection in Cooling Operation
!
NOTE
• “To change the temperature display to
Celsius or Fahrenheit, change LCD display by referring to page 14.”
• As the temperature distribution of the
remote controller installation space is
not Uniform, slight difference can be
generated between the actually felt temperature and the room temperature indication of the remote controller.
Fan Speed Selection in Heating, Dry, Fan,
Auto-Operation
Child Lock
It is the function to use preventing children
or others from careless using.
1 Press
button and
button Simultaneouslly for more than 3 seconds.
!
NOTE
• If the product is not compatible with
The fan speed control, it will not function as per your selection.
!
NOTE
• After the setting of the ‘CL’, if another
button is setup , the button can not be
recognized as the ‘CL’ is indicated at
the temperature display section.
Download PDF