LG | DM9H-DOM9H | LG DM9H/DOM9H Owner’s Manual

ENGLISH
Room Air Conditioner
OWNER'S MANUAL
SPLIT TYPE ROOM AIR CONDITIONER
?
Please read
?
Contact the authorized SVC
carefully
and
thoroughly
man
for
this manual before
repair
or
?
Contact the installer for installation of this unit.
?
The
operating
this unit.
maintenance of this unit.
appliance is not intended for use by young
supervision.
Young children should be supervised to ensure
appliance.
children
or
infirm persons
without
?
that
Prior to installation, this
they
do not
play
with the
air-conditioning unit must
approval by the utility service which
provides electricity (EN 60555-3 Norm).
be
submitted for
P/No.: 3828A30006X
GRE K
CONTENTS
SAFETY PRECAUTIONS...............................................................................3
Installation
precautions................................................................................3
Operation precautions .................................................................................4
PRODUCT COMPONENT IDENTIFICATION ...............................................7
(1)
(2)
(3)
(4)
Feature ..................................................................................................7
Indoor Unit, Outdoor Unit ......................................................................8
Name and Function-Remote Controller .................................................9
Remote Controller
Preparation
...........................................................10
AIR CONDITIONER OPERATION ...............................................................11
(1)
(2)
(3)
(4)
(5)
(6)
(7)
Operation Mode ...................................................................................11
Operation Procedure ...........................................................................11
Sleep Mode Auto-Control Setting ........................................................17
Airflow Direction Procedure .................................................................18
Setting the Present Time .....................................................................19
Timer Setting .......................................................................................20
Operation Details ................................................................................22
FORCED OPERATION.................................................................................23
CARE AND MAINTENANCE ......................................................................24
OPERATION TIPS .......................................................................................26
BEFORE CALLING FOR SERVICE ............................................................27
NOTE ...........................................................................................................28
SAFETY PRECAUTIONS
To
prevent injury
to the
user or
other
Incorrect
the
operation due to ignoring
following indications.
WARNING
CAUTION
The items to be followed
people
and
the
properties damage,
of instruction will
cause
harm
or
following instructions must be followed.
damage, the seriousness is classified by
: This indication shows the possibility of causing death
or
serious
: This indication shows the possibility of causing injury
or
damage
injury.
to
properties only.
are
classified
by
the
following symbols.
Symbol(with
doing.
white
background)
denotes item that is PROHIBITED from
Symbol(with
white
background)
denotes item that is COMPULSORY to
be carried out.
WARNING
Do not install,
Improper
remove
installation will
authorized dealer
or
and reinstall the unit
water
cause
specialist
leakage,
by yourself.
electrical shock
or
fire. Please consult
for the installation work.
CAUTION
Please confirm the
This
room
following important points
when installation.
air conditioner must be earthed.
The
reverse
based
It may
cause
grounding
electrical shock if
is not
Do not install the unit at
of flammable gas may
perfect.
place
occur
where
leakage
and/or in
an
of gas leaks and accumulates
at the surrounding of the unit, it may
cause fire ignition.
drainage piping
properly.
is connected
If it is not connected
cause
water
furniture.
leakage
perfectly, it may
and dampen the
is
absorbs heated air from the outdoor unit and
it indoor.
Therefore if the outdoor unit is
low
exposed
in the very
temperature, specifically below 0°C, the
heating capacity drops
case
Confirm
cycle system of the air conditioner
cooling type heat pump which
the air
discharges
explosive atmosphere.
In
on
off
rapidly.
WARNING
?
Otherwise, it will
shock
or
cause
electrical
?
fire due to heat
generation
or
It will
electrical shock
cause
due to heat
or
fire
generation.
?
It will
?
If the
electrical shock.
cause
electrical shock
cord is
It will
cause
due to heat
?
This could
electrical shock
or
fire
?
It may
cause
electrical shock.
?
supply
damaged,
replaced by the manufacturer or its
service agent or a similarly qualified
your health.
?
If the unit continues to be
in
operated
?
hazard.
rotates
this may
cause an
If this is done in
abnormal condition, it may
cause a fire, trouble, etc. In this
cause a
case, consult your dealer.
leakage,
an
a
Since the fan
speed,
generation.
damage
fire.
be
person in order to avoid
?
or
it must
at high
injury.
correctly,
it may
fire, electric shock, injury
by dropping of the unit, water
etc. Consult your dealer.
CAUTION
?
?
It may
cause an
injury.
Since the fan rotates at
during operation,
injury.
high speed
it may
?
Water may enter the unit and
degrade the insulation. It may
cause an electric shock.
?
?
This could
?
injure
the
pet
or
plant.
An oxygen
Do not
cause an
electric shock.
occur.
this air conditioner to
preserve
It may
It may
use
may
precision devices, food,
animal, plants and art objects.
cause an
quality,
?
shortage
?
It may cause a fire
of the cabinet.
or
deformation
?
cause
deterioration of
etc.
It may cause
combustion.
imperfect
For installation
CAUTION
When the unit is not going
to be used for a long time,
turn off the breaker.
WARNING
Do not operate for a long time
in high humidity, e.g. leaving
a door or window open.
Consult your dealer for
installing the air conditioner.
?
?
It may
cause an
injury.
?
In the cooling mode, if it is
operated in a room with high
humidity (80%r.h. or more) for a
long time, water condensed in
the air conditioner may drop and
may wet and spoil furniture, etc.
CAUTION
Apply grounding.
?
Do not connect
to
Do not step on the
indoor/outdoor unit an do
not put anything on it.
?
It may
cause an
dropping
or
falling
injury through
down.
It may case
down.
an
injury,
etc.
gas
pipe,
grounding wire
pipe,
ground wire of a
a
water
lightning rod or
telephone.
If a grounding is incorrect,
Do not step onto an unstable
bench when
attaching/detaching the panel.
?
a
it may
electric shock.
cause an
by
falling
Install
place
earth
leakage
depending on the
an
breaker
where the air
conditioner is to be
?
installed.
(humid place, etc.)
If the earth
leakage
breaker is not installed,
it may cause an electric
shock.
Do not install the unit where
flammable gas could leak.
Do not leave
on
stand which is
?
installation
?
damaged.
If gas leaks and collect around the
unit, it may
cause an
explosion.
The unit may drop or fall down
and cause an injury.
Drain water should be
fully
drained.
?
If the
drainage
route is
incomplete,
water may drop from the unit. It
may wet and spoil furniture.
6
ENGLISH
PRODUCT COMPONENT IDENTIFICATION
(1) Feature
GASoft
Dry Operation Mode(page
This mode is
designed
to
dehumidify
ENGLISH
13)
without
overcooling.
GBAuto
Operation(page
In
14)
this mode of
selecting
operation, the
indoor
fan speed, and
setting temperature,
the desired operation mode are automatically
set by Fuzzy rule on the basis of sensing the
room
temperature.
During Auto Operation, the vertical louver
swings up and down automatically in
according to 1/f rhythm. Pressing the Airflow
Direction Control Button will set the louvers
as
position. If you want to go on
swing of vertical the louver, press
the desired
with the 1/f
again
the Airflow Direction Control Button.
GCON/OFF Dual Timer
You
program the
turn itself on or off so
can
room
Setting(page 21)
air conditioner to
as to ensure you
maximum comfort when you return from
Wireless Remote Controller puts
all functions at your fingertips.
being away.
GDSleep
CAUTION
Mode Auto
A touch of the
Control(page 17)
Mode Button
Sleep
automatically controls the indoor fan speed,
and adjusts the setting temperature to create
a more comfortable sleep.
of
?
handling
Aim at the
signal receptor
conditioner
?
so as
to
The remote control
a
?
the Remote Controller
the
on
room
air
operate.
signal
can
be received at
distance of up to about 7m.
Be
sure
that there
are no
obstructions
between the remote controller and the
signal
receptor.
?
Do not
drop or throw the remote controller.
place the remote controller in a
location exposed to direct sunlight, or near
the heating unit, or any other heat source.
Do not
?
Block
a
with
curtain
a
strong light
or
over
the
signal receptor
etc. so as to
prevent the
abnormal
operation.
(ex:electronic quick start, ELBA,
fluorescent lamp)
inverter type
ENGLISH
7
(2) Indoor Unit, Outdoor Unit
Indoor Unit
Air Intake Vent
(front panel)
Remote Controller
Storage
(12K BTU model)
Air Outlet Vent
Horizontal Airflow
Direction Louver
Air Filters
Vertical Airflow Direction Louver
air outlet vent opens when the
(The
starts.)
(behind
operation
front
panel)
Forced
Operation Button
operation when the remote control cannot be used.
(When operation is stopped by the remote control without
removing power plug, the room air conditioner consumes
approximately 2W of electricity.)
Indoor unit controls
and indicators
Used for
the front panel
Pull the both ends of
front panel and hang
upward like below
Open
Signal Receptor
Receives the signals from the remote control.
(Signal receiving sound:two short beeps or one long beep.)
picture.
Operation
Indication
On
:
Lamps
Lights
up
during
the air conditioner
operation.
Sleep
Mode
:
Lights
up
during Sleep
Mode Auto
operation.
Timer
:
Deice Mode
:
Lights
up
during
timer
Lights
up
during
Deice Mode
operation. (Blinks
on
operation.
and off
during
start) (Heat Pump Only)
OUT
DOOR
:
Lights
up
during
the compressor
operation.(Cooling Only)
Outdoor Unit
(Rear)
(Side)
Air Intake Vents
Piping
Air Outlet Vent
Drain Hose
Heat pump model: Room Air Conditioner for
Cooling
8
model: Room Air Conditioner for
ENGLISH
cooling
cooling
and
heating
hot
(3) Name and Function-Remote Controller
Remote Controller
GAOperation display
the
Displays
transmitter
Signal
Transmits the
signals
ENGLISH
operation
GBStart/Stop
Operation
to the room
conditions.
Button
starts when this button is
stops when the button is
air conditioner.
GC
Operation
?
?
1
AUTO
?
and
pressed again.
Mode Selection Button
Used to select the
?
pressed,
operation
Cooling Operation Mode.
mode.
Soft
Dry Operation Mode.
Auto Operation Mode.
Heating Operation Mode. (Heat Pump Only)
GDON Timer Button
ON
TIME
OFF
a.m.
a.m.
p.m.
p.m.
TIME
Used to set the time of
Hr.
starting operation.
GEOFF Timer Button
2
3
5
ON
Used to set the time of
GF
9
GG Timer
adjust
the time.
Set Button
Used to set the timer when the desired time is
10
6
Button
Setting
Used to
OFF
4
SET
Time
stopping operation.
obtained.
CANCEL
7
11
GH Timer
8
12
13
RESET
CANCEL Button
Used to cancel the timer
GISleep
Mode Auto Button
Used to set
GJ
FAN
Sleep
Operation
Used to circulate
GK
Room
Mode Auto
Operation.
Button
room
air without
cooling
Temperature Checking
Used to check the
GL
operation.
room
or
heating.
Button
temperature.
Airflow Direction Control Button
Used to set the desired airflow direction.
GM
Reset Button
ENGLISH
9
(4) Remote Controller Preparation
How to store the remote controller
How to mount onto
a
wall
(12K BTU model)
Pull the both ends of front
1
panel slightly
to open.
1
Use the
screws
to secure the holder to
the wall.
Confirm that the remote
Hang
2
the front
panel upward
and
keep
the remote controller.
(Remove
it when
reach
of unit.
signals can
signal receptor
To attach the remote controller to the
holder.
using.)
Press the left and the right side to close
the front panel. Press center slightly for
snap fit.
3
2
control
the
Snap
3
To
remove.
fit
How to insert batteries
1
Remove the
battery
cover
from the remote
RESET
?
controller.
Slide the
?
cover
to the arrow
according
Be
sure
that the
(+)
and
and
(-)
directions
are
RESET
?
correct.
?
Be
sure
rechargeable
dry
shape, dimensions,
performance.
cells in
Insert the two batteries.
?
use
differ from standard
direction.
2
Do not
batteries, such batteries
Romove the batteries from
the remote controller if the
that both batteries
are new.
air conditioner is not
to be used for some
3
10
Re-attach the
?
cover.
Slide it back into
ENGLISH
position.
RESET
time.
going
long
AIR CONDITIONER OPERATION
(1) Operation Mode
Cooling
Mode
Cooling
Mode
Soft
Mode
Soft
Mode
Dry
Dry
ENGLISH
Auto Mode
Auto Mode
(Cooling Model)
Heating
Mode
(Heat Pump Model)
(2) Operation Procedure
1st
Button
Start/Stop
AUTO
ON
2nd
Operation
TIME
OFF
a.m.
a.m.
p.m.
p.m.
TIME
Hr.
Mode Selection
1
Button
2
Heat pump model
Cooling
3rd
Room
4th
Indoor Fan
Temperature Setting
Button
model
3
4
Speed
Selection Button
ENGLISH
11
GA
Cooling Operation
LED
(
1
Mode
lamp ON)
Press the
Start/Stop
Button.
Beep,
beeps will sound
operation lamp will light up.
Two short
?
2
Select
Beep
and the
Cooling Operation.
Press the
Operation
Mode Selection Button.
Each time the button is
pressed,
the
operation
mode is shifted in the
arrow
direction.
Operation Display
Cooling Operation
3
Soft
Auto
Dry Operation
Set the temperature
lower than the room
?
The temperature can be set
a range of 18°C
30°C
1°C
To raise the
speed.
?
?
Each time the button is
shifted.
Temperature.
Select the fan
ENGLISH
The
display
speed.
pressed,
by
.
speed
in four
-low, medium, high, AUTO.
?
12
~
Temperature.
To lower the
Set the fan
Heating Operation
(Heat pump model only)
within
temperature.
4
Operation
the fan
shows
speed
high
mode is
fan
steps
GBSoft
Dry Operation
Mode
This mode dehumidifies without
LED
(
1
ENGLISH
overcooling.
lamp ON)
Press the
Start/Stop
Button.
Beep,
?
2
Select Soft
Press the
Beep
beeps will sound
operation lamp will light up.
Two short
and the
Dry Operation.
operation
Mode Selection Button.
Each time the button is
pressed,
the
operation
mode is shifted in the
arrow
direction.
Operation Display
Cooling Operation
3
Set the
Temperature
lower than the
Soft
room
Auto
Dry Operation
Heating Operation
(Heat pump model only)
Operation
temperature.
?
The temperature can be set
a range of 18°C~30°Cby
within
1°C.
To raise the
To lower the
4
Temperature.
Temperature.
During Dry Operation.
?
The indoor fan
impossible
speed
is
because of
automatically set to the low, so the shift of the indoor fan speed
already being set to the best speed for Dry Operatrion by Micom
is
Control.
?
The indoor fan may be
stopped
not so as to be the room
overcooling.
ENGLISH
13
GC
Auto
LED
(
1
Operation
Mode
lamp ON)
Press the
Start/Stop
Button.
Beep,
?
2
Select Auto
Press the
Beep
beeps will sound
operation lamp will light up.
Two short
and the
Operation.
Operation
Mode Selection Button.
Each time the button is
pressed, operation
mode is shifed in the
arrow
direction.
Operation Display
Cooling Operation
Soft
Dry Operation
Auto
Operation
Heating Operation
(Heat
3
Set the temperature.
?
pump model
only)
Operation mode, set temperature and fan speed are automatically
by Fuzzy rule on the basis of sensing the room temperature.
If you want to change the set temperature, press room
temperature setting button.
The cooler or warmer you feel, the more times (up to two times)
set
?
?
?
you press the button.
Then the set temperature will be
changed automatically by
micom
control.
4
During
?
?
Auto
feel too cool
To lower the
Temperature. (When you
feel too
or
cold.)
warm or
hot.)
speed during Auto Operation because of being
position by Fuzzy rule.
conditioner is not operating as desired, switch to cooling mode or other
impossible to
already set to the
room
Temperature. (When you
Operation.
It is
If the
To raise the
air
switch the indoor fan
best
mode.
?
14
During Auto Operation, pressing the Air-flow direction control button makes vertical louver
swings up and down automatically according to 1/f rhythm. If you want to stop the 1/f swing
of the vertical louver, press again the Airflow Direction Control Button.
ENGLISH
Mode
GDHeating Operation
(
1
LED
(Heat pump model only)
ENGLISH
lamp ON)
Press the
Start/Stop
Button.
Beep
Beep,
?
2
Select
beeps will sound
operation lamp will light up.
Two short
and the
Heating Operation.
Press the
Operation
Mode Selection Button.
Each time the button is
pressed,
the
operation
mode is shifted in the
arrow
direction.
Operation Display
Cooling Operation
Soft
Auto
Dry Operation
Operation
Heating Operation
(Heat
3
pump model
only)
Set the temperature.
?
The temperature can be set
a range of 16°C~30°Cby
within
1°C.
4
Set the fan
To raise the
Temperature.
To lower the
Temperature.
speed.
?
Each time the button is
?
Select the fan
?
The
speed in four steps
-low, medium, high, AUTO.
pressed,
display
the fan
shows
speed
high
fan
speed.
mode is
shifted.
ENGLISH
15
GE
FAN
(
1
Operation
LED
lamp ON)
Press the
Start/Stop
Button.
Beep,
?
2
3
16
Press FAN
Operation
Button.
Each time Indoor Fan
Speed
Selector is
pressed,
the fan
beeps will sound
operation lamp will light up.
Two short
speed
direction.
arrow
ENGLISH
?
Fan
speed
is low.
?
Fan
speed
is medium.
?
Fan
speed
is
?
Auto Air
high.
Beep
mode is shifted in the
and the
(3) Sleep Mode Auto
(
LED
-
Control
Setting
ENGLISH
lamp ON)
Remote Controller
?
Sleep Mode will be operated at a low fan
speed(Cooling) or a med. fan speed(Heating)
for quiet sleeping.
The
Press the
Sleep
Mode Auto
Button.
Hr.
p.m.
Beep,
ON
Beep
OFF
1. Press the
Sleep
Mode Auto Button and set
the time to turn off.
SET
2. Check the
CANCEL
room
Sleep
Mode Auto LED of the
air conditioner
3. The Timer is
pressing
the
lights up.
programmed by 1 hour each
sleep mode auto button from
1 hour to 7 hours.
RESET
In
?
?
Cooling mode
The setting temperature will be automatically
raised by 1°C 30 minutes later and by 2°C 1
hour later for comfortable sleeping.
In order to cancel the
the
button several times until star
on
the
Sleep Mode, press
pictograph
operation display disappears.
ENGLISH
17
(4) Airflow Direction Procedure
GA
Vertical Airflow Direction Control
Airflow Direction Control
The airflow direction
the
1Press
(Confirm
Start/Stop
the unit
on
be adjusted as desired by using the remote
yourself directly, such as after taking a bath.
can
when you want to cool
controller. This is effective
Caution
Button.
operation.)
?
Always
use
the remote controller to
airflow direction.
Manually moving
by hand could
airflow direction louver
operation
?
adjust
the
the vertical
cause
errors.
When air conditioner
operation
is
stopped,
the vertical airflow direction louver will close
the air outlet vent of
2
Press the Airflow Direction Control
Button and the vertical louvers
and down
3
Press
again
the Airflow Direction Control
Button to set the vertical louver at the
desired airflow direction.
18
swing up
automatically.
ENGLISH
room
air conditioner.
GBHorizontal Airflow Direction Control
Adjust the
by hand.
?
horizontal airflow direction
by manually moving
the horizontal airflow direction louver
(5) Setting the Present Time
The present time can be set
the remote controller.
1
Press the
Start/Stop
the RESET Button
or
only
when
Button after
changing
pressing
pressing
batteries
the reset button
2
or
when
Press the Time
being
replacing
Setting
batteries for
Button until
set the desired time.
for Remote Controller.
3
Press the Time SET Button.
SET
NOTE
:
Check
a.m.
and p.m. Indicator in
setting
time.
ENGLISH
19
ENGLISH
(6) Timer Setting
LED
(
lamp ON)
AUTO
Remote Controller
1
ON Timer Button
or
ON
TIME
OFF
a.m.
a.m.
p.m.
p.m.
TIME
Hr.
OFF Timer
Heat pump model
Button
Cooling
2
Time
3
Timer SET Button
4
Timer CANCEL Button
Setting
model
Button
ON
OFF
SET
CANCEL
1
2
34
RESET
1
Press the ON Timer Button
or
OFF Timer
To cancel the
settings
Button.
Press the Timer Cancel button.
ON
OFF
(The
CANCEL
2
Change
the Timer
timer
lamp
on
The timer
conditioner and the
will be
will go
Setting
setting
displayed.
the air
display
out.)
and press the
Timer Set Button.
SET
If the
settings
are
cancelled
by
a
power
failure.
Press the
Start/Stop Button, and then set
again as desired time according
Setting Procedure.
the timer
Timer
20
ENGLISH
to
Timer
Setting
Procedure
1
Confirm the present
2
Press ON Timer Button
ON
time.(Refer
or
to page
ENGLISH
19)
OFF Timer Button.
?
Select
one
of the
following
four types of
operation.
OFF
OFF
TIME
Operation stops
a.m.
Delay
at OFF Timer
Setting.
OFF Timer
Delay
ON Timer
Delay OFF
ON
Operation
TIME
a.m.
ON
TIME
OFF
a.m.
a.m.
p.m.
p.m.
Operation stops at OFF
at ON Timer Setting.
TIME
and ON Timer
Delay ON
and OFF Timer
starts at ON Timer
Setting.
p.m.
ON
TIME
OFF
a.m.
a.m.
p.m.
p.m.
Operation
TIME
starts at ON Timer
OFF Timer
NOTE
:
Timer
Setting
Setting
and starts
and stops at
Setting.
Check
a.m.
and p.m. Indicator in
setting
time.
3
Press the Time
Setting
set the desired time.
Button until
being
4
Set the Timer SET Button.
SET
ENGLISH
21
?
Soft
Dry Operation
Mode
When the
room temperature is higher than the setting temperature, it operates cooling mode as the
setting temperature, the setting fan speed (if CHAOS mode, then med.), and then it will be switched
Soft Dry Operation Mode when the room temperature reaches the setting temperature.
In Soft
the indoor fan
Dry Operation Mode,
speed
is
automatically
switched to the low.
ROOM
TEMP.
COOLING
ROOM TEMP.
SET TEMP. +1°C
SOFT DRY
SET TEMP. -0.5°C
SETTING
INDOOR
FAN
FAN
SPEED
¡ª LOW COOL
¡ª LOW COOL
OPERATION
OPERATION
OPERATE
COMP.
OPERATE
OPERATE
FOR
FOR
10MINS
10MINS
STOP
OPERATING START
Helpful
Airflow
The
and
cooling capacity
fan
cool the
7 MINS
cooling capacity.
indicated in the
the value when the fan
High
FOR
3 MINS
information
speed
capacity
STOP
FOR
speed
will be lower at low
specification is
high, and the
medium fan speed.
is set to
or
speed is recommended
room quickly.
when you wish to
High
Speed
to
FORCED OPERATION
Operation procedures when
the remote
control
can't be used.
Open
the front
Forced
and press the
panel upward
Operation Button.
If you want to stop operation, press again.
During Forced operation, the operating
conditions
are
automatically
set as the
following:
Heat pump Model
Cooling
Operating
FAN
mode
Speed
Setting Temp.
Model
Room
Temp. ≥ 24°C
Cooling
Cooling
High
High
22°C
22°C
24°C
>
Room
Soft
Soft
Temp.
21°C Room
≥
Dry
Dry
Temp. < 21°C
Heating
Rule
High
23°C
24°C
Press the Forced
Operation
Button.
Forced
Operation
Open the front
panel upward
Button
?
Press the Forced
once
again
to
Operation Button
stop operation.
CARE AND MAINTENANCE
Disconnect the power
plug
or
turn off
Remove the Air filters.
Take hold of the tab and
the breaker.
to
remove
pull slightly forward
the filter.
When the air filter is to be
removed, do not
touch the metal parts of the indoor unit.
When the unit is to be
cleaned, switch off
plug or turn off
and disconnect the power
the breaker.
Since the fan rotates at
operation,
it may
cause
high speed during
an injury.
It may
cause an
injury.
Clean dirt from the air filter using a
cleaner of by washing with water.
vacuum
If dirt is conspicuous, wash with a solution of
detergent in lukewarm water.
If hot water (50°C or more) is used, it may be
deformed.
Clean
soft
using
dry
cloth.
After washing with water,
the shade.
dry
Do not expose the air filter to direct
heat from a fire when drying it.
Never
?
?
use any of the followings:
Water hotter than 40°C.
Could cause deformation and/or
discoloration.
Volatile substances.
Could damage the surfaces of the air
conditioner.
Install the air filter.
SINNER
B
enzene
SCOURING
CLBARGER
Install it.
well in
sunlight
or
WHEN THE AIR CONDITIONER IS NOT GOING TO BE USED FOR A LONG TIME.
When it is not
going to be used for
a long time.
When the air conditioner is to
be used
Operate the air conditioner at the
following settings for 2 to 3 hours.
Type of operation: Fan operation
mode.(refer to page 16)
1
1
ENGLISH
again.
Clean the air filter and install it in the
indoor unit.
(Refer to page 24 for cleaning it.)
?
Clean it before
installing.
?
This will
2
dry
out the internal mechanisms.
Turn off the
breaker,
2
Check that the air inlet and outlet of the
indoor/outdoor unit
are
not blocked.
and disconnect the
plug.
CAUTION
Turn off the breaker when the air conditioner is
not
going
to be used for
a
Dirt may collect and may
3
long
time.
cause a
3
fire.
Check that the
is
connected
ground wire
correctly. It may
be connect
to the indoor unit side.
Remove the batteries from the remote
controller.
CAUTION
Apply grounding.
Do not connect
a grounding wire to a gas pipe,
pipe, lightning rod or ground wire of a
telephone. If a grounding is incorrect, it may
RESET
water
cause an
Helpful
electric shock.
information
Wasted!
The air filters and your electiric bill.
If the air filters become
will
clogged with dust,
drop, and 6% of the
cooling capacity
electricity used to operate
the
the air conditioner
will be wasted.
ENGLISH
25
OPERATION TIPS
Do not overcool the
room.
Keep
blinds
or
curtains
the
Keep
closed.
This is not
temperature
uniform.
Do not let direct sunshine
Adjust
health and wastes
enter the room when the air
horizontal airflow direction
electricity.
conditioner is in
to ensure a uniform
good
for the
room
operation.
the vertical and
temperature in the
room.
4~6°C
Make
sure
that the doors
and windows
Avoid
opening
windows
as
possible
to
in the
are
shut
keep
as
the cool air
room.
ENGLISH
Ventilate the
room
occasionally.
Blockages
in the air filter
reduce the airflow and lower
cooling
and
dehumidifying
effects. Clean at least
every two weeks.
26
regularly.
tight.
doors and
much
Clean the air filter
once
Since windows
closed, it is
a
are
good
kept
idea to
open them and ventilate the
room now and then.
BEFORE CALLING FOR SERVICE
Check the
before
following points
requesting repairs
service.... If the malfunction
or
persist, please
contact your dealer.
Does not
The
operate.
?
Have you made
mistake in timer
a
?
Has the fuse blown
or
has the circuit breaker
been
or
Is the air filter
See air filter
dirty?
cleaning
?
The
room may have
been very hot when the
room air conditioner
first turned
Has the
?
air.
cools the
room.
This is the
protector of
the mechanism.
?
Wait about three
minutes and
warm room
will
operation
begin.
a
freon
noise that sounds
?
For
a
outlet vents
?
flowing.
?
inside the
flowing
Are the batteries
Are the batteries
inserted in the
(+)
noise that sounds
compressed
releasing into
atmosphere.
and
(-)
Crack sound is heard.
no
depleted?
air conditioner unit.
the
incorrectly?
Are the indoor unit's air
or
For
Remote controller
display is faint, or
display at all.
opposite
directions?
?
This sound is
generated by the
expansion/constriction
of the front panel, etc.
due to changes of
temperature.
air
-This is the sound of
temperature
been set
inlet
occurs
in the
like the
on.
down.
?
Condensation
minutes when restart.
when the airflow from
the air conditioner
-This is the sound of
Allow time for it to cool
?
?
the walls, carpet,
furniture or cloth items
like water
instructions.
was
a
by
The air conditioner
operation is noisy.
heat
effectively.
?
smell exuded
Air conditioner does
operate for about 3
not
tripped?
Does not cool
?
It seems that
condensation is leaking
from the air conditioner.
a
odor.
Check that this is not
damp
operation?
?
has
room
peculiar
dehumidifying
being processed
water
inside the air
obstructed?
conditioning
unit.
NOTE
SPLASH PROOF
:
The outdoor side of this
appliance
is SPLASH PROOF and the indoor side is
ordinary.
ENGLISH
27
ENGLISH
NOTE
Please remember to record the
?
Model Number
?
Serial Number
?
Dealer's Name
?
Date Purchased
following:
Download PDF