http://biz.lgservice.com
Room Air Conditioner
SVC MANUAL(Exploded View)
CAUTION
Before Servicing the unit, read the safety precautions in General SVC manual.
Only for authorized service personnel.
1. Specification
BRAZIL'S PRODUCTION MODEL
SUFFIX
Buyer Model No.
Capacity
Cooling
[Kcal/h]
Heating
[Kcal/h]
Power Factor
Elelctrical Parts
Voltage,Frequency,Phase [V,Hz,p
Power Input. Cooling/Heating [Watt]
Running Current. Cooling/Heating [A]
Rerformance
EER
[Btu/hr. W]
EER
[W / W]
Air Circulation [In/Out]
[㎥/min]
Moisture Removal
[ℓ/hr]
Noise Level [In/Out]
[dB(A)±3]
Features
Nano PLASMA Air Purifying System
Gold Fin
Temperature Control
CHAOS Swing
Auto Changeover
Auto Cleaning
Hot Start
Air Direction Control[Up&down]
Air Direction Control[left&right]
Remote Controller type
Setting Temperature Range
[Cool/Heat]
Micom Control
Timer
Auto Restart
Jet Cool
Healthy Dehumiditfication
Restart Delay
Comperessor type
Installation & Stuffing
Net Dimensions
Indoor WxHxD
Outdoor WxHxD
Net weight In/Out
Connecting tube
Liquide side mm[in]
Gas side
mm[in]
Length,std
m[in]
Stuffing Quantity
Without S/parts
Note:
O : Applied, - : No relation
* For circuit breaker rating, please conform to local standards wherever necessary.
2 Room Air Conditioner
TS-C186KGA5
AMBBDXB
4 536
98%
220-240V,50,1
2 100
9.5
8.57
2.51
13.24/51
2.3
42/56
Y
Y
Y
New Chaos
N
N
N
Auto
Manual
Wireless LCD
18-30
Y
7Hr.Off
Y
Y
Y
3
Rotary,QJ306PCB
1090*214*276
840*577*276
13/60
6.35
18.7
5
Some of functions are slightly different depending upon models.
The specification may be subject to change without prior notice for purpose of
improvement.
2. Piping Diagrams
Indoor Unit
Outdoor Unit
Capillary Tube
Liquid Side
2-Way Valve
Th2
Th1
Heat
Exchanger
(Evaporator)
Heat
Exchanger
(Condenser)
Compressor
Gas Side
Accumulator
3-Way Valve
High Pressure S/W
Cooling
LOC.
Description
PCB Conn ector
Th1
Thermistor for indoor air temperature
Th2
Thermistor for evaporating temperature
CN-TH1
(2) Cooling & Heating Models
INDOOR UNIT
OUTDOOR UNIT
LIQUID SIDE
CHECK VALVE
(Heating Model only)
3-WAY VALVE
CAPILLARY TUBE
HEAT
EXCHANGE
(EVAPORATOR)
HEAT
EXCHANGE
(CONDENSER)
GAS SIDE
3-WAY VALVE
REVERSING
VALVE
(Heating Model Only)
ACCUMU
LATOR
COMPRESSOR
COOLING
HEATING
Ser vice Manual 3
3. Wiring Diagrams
ZNR
STEP
MOTOR
U/D
CN-TAB2
SH-CAPA
SSR
FORCE
S/W
STEP
MOTOR
F/G
BR YL
THERMISTOR
STEP
MOTOR
F/G
MOTOR BK
CN-TH
CN-MOTOR
OR
PCB ASM
CN-TAB1
BR
BL
GN/YL
POWER
CN-U/D
Indoor Unit
FUSE
CN-SUB
RY-COMP
CN-FORCE
CN-F/G(R) CN-F/G(L)
SUB PCB
CN-HVB
GN/YL
BL
AIR
CLEANER
PLASMA
GN/YL
DISPLAY PCB ASM
BL
BR
T/BLOCK
3 USE FOR PLASMA MODEL
INDOOR WIRING DIAGRAM
TO OUTDOOR UNIT
FUSE
CN-N2
CN-N1
CN-MOTOR
4 Room Air Conditioner
LIMT
SWITCH
H.V RD
ASM BK
BK BK
CN-DISPLAY
BK BK
BR
CN-LIMT
MEZ49480001
RY-COMP3 RY-COMP4 CN-U/D
CN-SUB
Outdoor Unit
BLUE
CAPACITOR
RED
S
R
H
C
F
BLUE
BLUE
YELLOW
ORANGE
OVERLOAD
PROTECT
C
FAN
4
TERMINAL BLOCK
RED
3
BLACK
BLUE
BROWN
1(L) 2(N)
BROWN
YELLOW/GREEN
BLUE
BLUE
BLACK
VALVE,REVERSING
THE UNIT INDOOR
OUTDOOR DIAGRAM WIRING
MEZ48932604
Capacitor
Terminal Block
Ser vice Manual 5
Exploded View
Exploded View
1. Indoor Unit
135316
135301
135314
135511
152302
W3300
131410
359011
342800
354210
435301
147582-1
147582-2
147581-1
268712
346810
35211B
135516
354212
263230
352150
135311
249941
146811
264110
W0FZZ
W6640
267110
249951
Room Air Conditioner
268711
W0CZZ
P/NO :MFL37322704
JUNE, 2009

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

advertisement