advertisement
▼
Scroll to page 2
of 7
http://biz.lgservice.com Room Air Conditioner SVC MANUAL(Exploded View) CAUTION Before Servicing the unit, read the safety precautions in General SVC manual. Only for authorized service personnel. 1. Specification BRAZIL'S PRODUCTION MODEL SUFFIX Buyer Model No. Capacity Cooling [Kcal/h] Heating [Kcal/h] Power Factor Elelctrical Parts Voltage,Frequency,Phase [V,Hz,p Power Input. Cooling/Heating [Watt] Running Current. Cooling/Heating [A] Rerformance EER [Btu/hr. W] EER [W / W] Air Circulation [In/Out] [㎥/min] Moisture Removal [ℓ/hr] Noise Level [In/Out] [dB(A)±3] Features Nano PLASMA Air Purifying System Gold Fin Temperature Control CHAOS Swing Auto Changeover Auto Cleaning Hot Start Air Direction Control[Up&down] Air Direction Control[left&right] Remote Controller type Setting Temperature Range [Cool/Heat] Micom Control Timer Auto Restart Jet Cool Healthy Dehumiditfication Restart Delay Comperessor type Installation & Stuffing Net Dimensions Indoor WxHxD Outdoor WxHxD Net weight In/Out Connecting tube Liquide side mm[in] Gas side mm[in] Length,std m[in] Stuffing Quantity Without S/parts Note: O : Applied, - : No relation * For circuit breaker rating, please conform to local standards wherever necessary. 2 Room Air Conditioner TS-C186KGA5 AMBBDXB 4 536 98% 220-240V,50,1 2 100 9.5 8.57 2.51 13.24/51 2.3 42/56 Y Y Y New Chaos N N N Auto Manual Wireless LCD 18-30 Y 7Hr.Off Y Y Y 3 Rotary,QJ306PCB 1090*214*276 840*577*276 13/60 6.35 18.7 5 Some of functions are slightly different depending upon models. The specification may be subject to change without prior notice for purpose of improvement. 2. Piping Diagrams Indoor Unit Outdoor Unit Capillary Tube Liquid Side 2-Way Valve Th2 Th1 Heat Exchanger (Evaporator) Heat Exchanger (Condenser) Compressor Gas Side Accumulator 3-Way Valve High Pressure S/W Cooling LOC. Description PCB Conn ector Th1 Thermistor for indoor air temperature Th2 Thermistor for evaporating temperature CN-TH1 (2) Cooling & Heating Models INDOOR UNIT OUTDOOR UNIT LIQUID SIDE CHECK VALVE (Heating Model only) 3-WAY VALVE CAPILLARY TUBE HEAT EXCHANGE (EVAPORATOR) HEAT EXCHANGE (CONDENSER) GAS SIDE 3-WAY VALVE REVERSING VALVE (Heating Model Only) ACCUMU LATOR COMPRESSOR COOLING HEATING Ser vice Manual 3 3. Wiring Diagrams ZNR STEP MOTOR U/D CN-TAB2 SH-CAPA SSR FORCE S/W STEP MOTOR F/G BR YL THERMISTOR STEP MOTOR F/G MOTOR BK CN-TH CN-MOTOR OR PCB ASM CN-TAB1 BR BL GN/YL POWER CN-U/D Indoor Unit FUSE CN-SUB RY-COMP CN-FORCE CN-F/G(R) CN-F/G(L) SUB PCB CN-HVB GN/YL BL AIR CLEANER PLASMA GN/YL DISPLAY PCB ASM BL BR T/BLOCK 3 USE FOR PLASMA MODEL INDOOR WIRING DIAGRAM TO OUTDOOR UNIT FUSE CN-N2 CN-N1 CN-MOTOR 4 Room Air Conditioner LIMT SWITCH H.V RD ASM BK BK BK CN-DISPLAY BK BK BR CN-LIMT MEZ49480001 RY-COMP3 RY-COMP4 CN-U/D CN-SUB Outdoor Unit BLUE CAPACITOR RED S R H C F BLUE BLUE YELLOW ORANGE OVERLOAD PROTECT C FAN 4 TERMINAL BLOCK RED 3 BLACK BLUE BROWN 1(L) 2(N) BROWN YELLOW/GREEN BLUE BLUE BLACK VALVE,REVERSING THE UNIT INDOOR OUTDOOR DIAGRAM WIRING MEZ48932604 Capacitor Terminal Block Ser vice Manual 5 Exploded View Exploded View 1. Indoor Unit 135316 135301 135314 135511 152302 W3300 131410 359011 342800 354210 435301 147582-1 147582-2 147581-1 268712 346810 35211B 135516 354212 263230 352150 135311 249941 146811 264110 W0FZZ W6640 267110 249951 Room Air Conditioner 268711 W0CZZ P/NO :MFL37322704 JUNE, 2009
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement