USER’S MANUAL
Wireless Remote Controller
R05/BGE
System Air Conditioner
remocon_IB_OEM_E.indd
9
2007-02-14
ソタタ・10:40:57
Note
 The outline figure on cover is for reference only,
which may differ from what you purchased.
 Make sure to read chapter ‘Precautions’ before
you operate the air conditioner.
 This manual is available for model R05/BG.
 R05/BGE can be applicable for cool only type and
cool&heat type air conditioners.
Contents
 PRECAUTIONS ...................................................................................
MODEL AND SPECIFICATION ...........................................................
BUTTONS AND THEIR FUNCTIONS ....................................................
 INDICATORS AND FUNCTIONS ..........................................................
 OPERATION INSTRUCTIONS ..............................................................


3
3
4
6
7
E-2
remocon_IB_OEM_E.indd
2
2007-02-14
ソタタ・10:40:48
Precautions
 Curtain, door or the like objects will prevent the remote signal
from being received by air conditioner.
 Do not get the interior of remote controller wet.
It is forbidden to expose it to direct sunlight or locate it in the
place with high temp.
 Malfunction may occur if infrared signal receiver on air
conditioner is exposed to sunlight. Please shelter the signal
receiver from sunlight with curtain.
 Please remove the nearby electronic device for they may affect
the performance of remote controller. If necessary, contact the
local Midea service centre or technical support centre.
 Do not put the used or different batteries into the remote
controller, otherwise remote controller will fail to send signal.
 Please remove the batteries before long period unused,
otherwise the remote controller may be damaged.
 If pressing the button reset the remote controller, which
indicates low battery, please replace the batteries.
 If no receiving sound is heard from indoor unit or
on remote
controller does not flash, please replace the batteries.
 Effective transmitting distance of remote controller is 8m,
please aim the signal sending part to the receiver on
air conditioner.
Model and Specification
Model
R05/BGE
Rated voltage
3.0V
(2 pieces of LR03 7# batteries)
Min voltage for sending signal of CPU 2.4V
Effective receiving distance
8m~11m
Operation condition
-5~60°C
E-3
remocon_IB_OEM_E.indd
3
2007-02-14
ソタタ・10:40:48
Buttons and their Functions
AUTO
COOL
Mode setting
Adjust
1
DRY
HEAT
FAN
TEMP
SET
2 Fan speed setting
CLOCK
SET
HOUR
FAN SPEED
4
3
FAN
SPEED
MODE
ON/OFF
5
Horiz swing
7
Vert. swing
8
SWING
AIR DIRECTION
CLOCK
SWING
OK
TIME ON
ECO
TIME OFF
RESET LOCK C/H
Reset
12
Lock
13
Cool/heat
15
Adjust
6
Air direction setting
9
Time setting
10
Time ON
11
Time OFF
14
Confirm button
16
Economic operation
E-4
remocon_IB_OEM_E.indd
4
2007-02-14
ソタタ・10:40:53
1
MODE: Once pressing, running mode will be selected in the following sequence:
AUTO
COOL
Note
2
DRY
HEAT
FAN
No heating mode for cool only type unit.
FAN SPEED: Fan speed will be selected in following sequence once pressing this button:
AUTO
LOW
MED
HIGH
3
Adjust: Decrease the set temp. Keeping pressing will decrease the temp with 1°C per 0.5s.
4
Adjust: Increase the set temp. Keeping pressing will increase the temp with 1°C per 0.5s.
5
ON/OFF : For turning on or turning off the air conditioner.
6
AIR DIRECTION : Activate swing function of air deflector. Once pressing, air deflector will
turn 6°C . For normal operation and better cooling and heating effect, deflector will not
turn to the degree which is the state of deflector when the unit is turned off.
( Only available when remote controller is used with corresponding unit.)
7
HORIZ SWING : Activate or turn off horizontal swing function.
(Only available when emote controller is used with corresponding unit.)
8
VERT SWING : Activate or turn off vertical swing function.
(Only available when remote controller is used with corresponding unit.)
9
CLOCK : Display the current time. (12:00 is displayed when resetting or electrifying for the
first time.) Press CLOCK for 5s, icon indicating hour will flash with 0.5s. Press it again,
icon indicating minute will flash with 0.5s. and are used to adjust the figure.
Setting or modification is effective only by pressing OK button to make confirmation.
10 TIME ON : For time ON setting. Once pressing this button, the time will increase by 0.5
hour. When the set time exceeds 10 hours, pressing the button will increase the time by
1 hour. Adjusting the figure to 0.00 will cancel time ON setting.
11 TIME OFF: For time OFF setting. Once pressing this button, the time will increase by 0.5
hour. When the set time exceeds 10 hours, pressing the button will increase the time by
1 hour. Adjust the figure to 0.00 will cancel time ON setting.
12 RESET (inner located): Press this button with a needle of 1mm to cancel the current
setting and reset remote controller.
13 LOCK (inner located): Press this button with a needle of 1mm to lock or unlock the current setting.
14 OK: Used to confirm the time setting and modification.
15 COOL / HEAT (inner located): Press this button with a needle of 1mm to shift mode between COOL
only and COOL&HEAT. During setting, back light will be lightened. Factory default mode is COOL &HEAT.
16 ECO: Activate or turn off economic operation mode. It is suggested to turn on this function
when sleeping. (Only available when remote controller is used with corresponding unit.)
E-5
remocon_IB_OEM_E.indd
5
2007-02-14
ソタタ・10:40:55
Indicators and Functions
Temp
1
Transmitting display
2
Running mode
AUTO
COOL
DRY
HEAT
FAN
Economic operation
remocon_IB_OEM_E.indd
6
ON/OFF
8
TEMP
SET
5
Time
CLOCK
SET
6
Lock
HOUR
FAN SPEED
ON
OFF
7
Time ON/OFF
9
Fan speed
1
Temp: Display the set temperature. Adjust temperature via
and. No display in this area if the unit is on FAN mode.
2
Transmitting display: The icon will flash once when the signal
is sent by remote controller.
3
ON/OFF: Icon is displayed when the remote controller is
turned on, or vice versa.
4
Running mode: Press MODE to display current running mode.
AUTO, COOL, DRY, HEAT and FAN can be selected.
(HEAT function is invalid for cool only type unit.)
5
Time: Display the current set time. Press CLOCK for 5s, icon
indicating hour will flash. Press this button again, icon
indicating minute will flash. andare used to adjust the
figure. Setting or modification is effective only by pressing OK
button to make confirmation.
6
Lock: The icon will be lightened or off when pressing LOCK.
In locked state, all the buttons are ineffective except button LOCK.
7
Time ON/OFF: In the state of time ON, icon ON will be
lightened, which is the same to the state of time OFF.
Setting timer ON and OFF simultaneously, both icons ON and
OFF are displayed.
8
Fan speed: Press FAN SPEED to display the current wind
speed. AUTO, LOW, MED and HIGH can be selected.
The default state is high fan speed for the unit without
medium fan speed.
9
Economic operation: This icon will be lightened or off when
pressing ECO button.
Note
E-6
3
4
All the above icons will be displayed only when the
remote controller is electrified for the first time or reset.
2007-02-14
ソタタ・10:40:56
Operation Instructions
Install and replace Install 2 pieces of 7# alkaline batteries.
batteries
Slide the cover to install batteries and make
sure to place them in right pole.
AUTO operation
Switch on the power and running indicator
light on indoor unit flashes.
1. Press MODE to select AUTO.
2. Adjust temp via and. Generally the
range is 17°C~30°C .
3. Press ON/OFF and running indicator light on
indoor unit is lightened.
Air conditioner will work on AUTO mode and
fan speed is AUTO which is nonadjustable.
4. ECO is effective on AUTO operation.
COOL/HEAT/FAN
operation
1. Press MODE to select COOL, HEAT or FAN.
2. Adjust temp via and . Generally the
range is 17°C~30°C .
3. Press FAN SPEED to select AUTO, LOW, MED
or HIGH.
4. Press ON/OFF and running indicator light on
indoor unit is lightened.
Air conditioner will work on the set mode.
Stop operation via ON/OFF.
Note
DRY operation
On FAN mode, temp is nonadjustable
and ECO is ineffective. Procedure 2 is
omitted.
1. Press MODE to select DRY.
2. Adjust temp and.
Generally the range is 17°C~30°C .
3. Press ON/OFF and running indicator light
on indoor unit is lightened.
Air conditioner will work on DRY mode.
Turn off the unit via ON/OFF.
4. On DRY mode, ECO and FAN SPEED are
unavailable.
E-7
remocon_IB_OEM_E.indd
7
2007-02-14
ソタタ・10:40:57
Operation Instructions (Continued)
Timer operation
TIME ON and TIME OFF are used to turn on and turn off the unit at the set
time respectively.
TIME ON operation
1. Press TIME ON, icon SET, HOUR and ON are lightened.
2. Press TIME ON again and adjust the time.
3. Keep pressing this button, the time will increase by 0.5 hour.
When the set time exceeds 10 hours, pressing the button will increase
the time by 1 hour.
4. 0.5s after setting, remote controller will send TIME ON command to the
unit.
TIME OFF operation
1. Press TIME OFF, icon SET, HOUR and OFF are lightened.
2. Press TIME OFF again and adjust the time.
3. Keep pressing this button, the time will increase by 0.5 hour.
When the set time exceeds 10 hours, pressing the button will increase
the time by 1 hour.
4. 0.5s after setting, remote controller will send TIME OFF command to the
unit.
Set TIME ON and TIME OFF simultaneously
1. Set TIME ON according to procedures 1 and 2 specified in TIME ON
operation.
2. Set TIME OFF as the procedures 1 and 2 specified in TIME OFF operation.
3. If both the set time of TIME ON and TIME OFF not exceed 10 hours,
time OFF operation will activated 0.5 hour later than time ON operation.
If both the set time of TIME ON and TIME OFF exceed 10 hours, time OFF
operation will be activated 1 hour later than time ON operation.
4. 0.5s after setting, remote controller will send TIME ON command to the
unit.
Modification of timer operation
Press corresponding button and readjust the time of time ON and time OFF.
Adjust the time figure to 0.00 to cancel the timer operation.
Note
The time set in timer operation is the relative figure based on the
clock on remote controller. Adjusting clock is unavailable when
TIME ON or TIME OFF is activated.
E-8
remocon_IB_OEM_E.indd
8
2007-02-14
ソタタ・10:40:57