Safety Precautions
The following safety precautions must be taken when using your air conditioner.
WARNING
DURING
OPERATION
Risk of electric shock. • Can cause injury or death. • Disconnect all
remote electric power supplies before servicing, installing or cleaning.
• This must be done by the manufacturer or its service agent or a similar
qualified person in order to avoid a hazard.
Users of this product are cautioned not to attempt repair of this product at their
own discretion. Instead, they are requested to directly contact a designated
service center or the outlet at which the product was purchased.
Never spill any kind of liquid into the unit. Should this happen, unplug or main
switch off the unit and contact an authorized service center.
Do not insert anything between the air outlet blades because the inner fan may
be damaged and could cause injury. Keep children away from the unit.
Do not place any obstacles in front of the unit.
Do not spray liquid of any kind into the indoor unit. Should this happen, switch off
the breaker used for your air conditioner and contact your installation specialist.
Make sure that the unit is correctly ventilated at all times:
Do not place clothing or other materials over it.
If the wireless remote control will not be used for a long time, remove the
batteries. (If applicable)
When using a wireless remote control, the distance should not be more than 7
meters from the air conditioner. (If applicable)
The air conditioner must be plugged into its own specific power source, which
must be installed in compliance with national wiring,earthing and safety
regulations.
If the power cord is damaged in any way, it must be replaced by the manufacturer
or its service agent or a similarly qualified person in order to avoid a hazard.
This device must be installed according to the national electrical rules.
The appliance must be installation that the plug should be easily accessible
after installation.
If the fuse on PC board is broken please change it with the type of T 3.15A 250V.
The breaker of the air conditioner should be all-pole switch; and the distance
between its two contacts should be no less than 3.5mm. Such means for
disconnection must be incorporation in the fixed wiring.
DISPOSING OF THE UNIT
Before throwing out the device, it is necessary to pull back the battery cells and
get rid of them safely for recycling reasons.
When you need to dispose of the unit, consult your dealer. If pipes are removed
incorrectly, refrigerant may blow out and come into contact with your skin,causing
injury. Releasing refrigerant into the atmosphere also damages the environments.
Please recycle or dispose of the packaging material for this product in an
environmentally responsible manner.
OTHERS
Never store or ship the air conditioner upside down or sideways to avoid damage
to the compressor.
The appliance is not intended for use by young children or infirm persons without
supervision: Young children should be supervised to ensure that they do not play
with the appliance.
Max current is measured according to IEC standard for safety and current is
measured according to ISO standard for energy efficiency.
E-2
AW05MOYEA_E/O_08574
12/12/02 4:24 PM
Page 3
Contents
◆ PREPARING YOUR AIR CONDITIONER
■
■
■
Safety Precautions .........................................................................................
Description of Each Component ....................................................................
Getting Started ...............................................................................................
2
4
5
◆ OPERATING YOUR AIR CONDITIONER
■
■
■
Cooling Your Room ........................................................................................
Switching the Air Conditioner Off ....................................................................
Adjusting the Air Flow Direction Horizontally ..................................................
6
7
7
◆ RECOMMENDATIONS FOR USE
■
■
■
■
■
Power Failure ................................................................................................. 8
Temperature and Humidity Ranges ................................................................ 8
Cleaning Your Air Conditioner ........................................................................ 9
Solving Common Problems ............................................................................ 10
Technical Specifications ................................................................................. 11
◆ INSTALLATION
E-3
Description of Each Component
❄ The design and shape are subject to
change.
Air outlet
Inner air flow
blades (right/left
orientation)
Air outlet
Air inlet (Inside)
Air inlet (Outside)
Adhesive bottom gasket
(Refer to page 13)
Air filter (Inside)
Power plug
(The type of power plug
may differ, depending on
the local power supply.)
OFF
5
Low Fan
Hi Fan
6
4
7
3
Operating mode
selection dial
8
2
Low Cool
Hi Cool
9
1
10
Med Cool
Selector
E-4
Thermostat
Thermostat
control
Getting Started
You have just purchased a Samsung window-type room air conditioner which should be
installed following your Owner’s Instructions.
Your Owner's Instructions contain much valuable information on using your air conditioner.
Please take the time to read them as they will help you take full advantage of the unit's
features.
The illustrations in the step-by-step procedures use four different symbols:
PRESS
PUSH
☛
➢
IMPORTANT
NOTE
E-5
Cooling Your Room
You must select the COOL mode if you wish to adjust the:
◆ Cooling temperature
◆ Fan speed when Cooling
1
2
Turn the operating mode selection dial and set it to “ Hi Cool ” ,
“ Med Cool ” or “ Low Cool ”.
Result:
The air conditioner starts up in cool mode.
➢
You can change modes at any time.
Turn the THERMOSTAT control to the desired position.
Possible temperatures: Can be set between 64°F and 84°F.
Result:
3
E-6
The air conditioner starts cooling if the room temperature is
higher than the selected temperature.
To control the direction of the air flow, refer to page 9.
AW05MOYEA_E/O_08574
12/12/02 4:24 PM
Page 7
Switching the Air Conditioner Off
You can switch the air conditioner off whenever you want.
1
To switch the unit off, simply set the operating mode selection dial to the
" Off " position.
Result:
The air conditioner stops operating.
Adjusting the Air Flow Direction Horizontally
Depending on the position of the unit in your room, you can adjust
the orientation of the inner air flow blades on the unit.
Adjust the air flow blades to the desired position by pushing them side to side.
E-7
Power Failure
If a power failure occurs, the air conditioner is switched off.
When the power comes back on, the air conditioner starts up again
automatically.
Temperature and Humidity Ranges
The following table indicates the temperature and humidity ranges
within which the air conditioner can be used.
E-8
Mode
Indoor
Temperature
Outdoor
Temperature
Indoor Humidity
Cooling
70°F to 90°F approx.
70°F to 110°F approx.
80% or less
If the air conditioner is used at...
Higher temperature
Then...
The automatic protection feature may be triggered
and the air conditioner stopped.
Lower temperature
A water leakage or some other malfunction may happen
if the heat exchanger freezes.
Higher humidity levels
Water may condense on and drip from the surface of the unit
if it is used for long periods.
Cleaning Your Air Conditioner
Be sure to clean the air filter periodically to maintain the air conditioner
in the best condition for a long period of time.
☛
When cleaning the air conditioner, turn it off and pull out the
power plug.
1
Open the front grille by pulling the tabs on both sides of the grille.
Then lift it up slightly to open the front grille completely.
2
Grab the tabs on the filter and pull it up and out.
3
Remove all dust on the air filter with a vacuum cleaner or brush.
4
When you have finished, insert the air filter back into its original position.
5
Wipe the surface of the unit with a neutral detergent
and then wipe it again with dry cloth.
(Be sure not to use benzene, solvent or other chemical products.)
➢
If you...
Then...
Will not be using the
air conditioner for a
long period of time
◆ Set the fan going for a few
hours to dry the inside of the air
conditioner thoroughly.
◆ Switch the air conditioner off and
unplug it from the wall socket.
◆ Clean the filter and outer surfaces.
Have not used the air
conditioner for a long
period of time
Set the fan going for a few hours to
dry the inside of the air conditioner
thoroughly.
E-9
Solving Common Problems
Before contacting an authorized service center, perform the following simple checks.
They may save you the time and the expense of an unnecessary call.
E-10
Problem
Explanation / Solution
The air conditioner
does not operate at all.
◆ Check for a power failure.
◆ Check the voltage.
(See the technical specifications)
◆ Check the power plug for disconnection.
◆ Check to see whether the operating mode selection dial is placed in the
" Off " position. (Set it to the desired position.)
◆ Check to see whether the room temperature is too low.
- Refer to page 10 for details about temperature condition.
The air comes out smoothly,
but cooling is not effective.
◆ Set the THERMOSTAT control to the desired position.
- When the number on the THERMOSTAT control is too high,
the room temperature may be too warm.
◆ Check to see whether there is an open window or other leakage of cool
air to the outside.
- Close the window, and fill the gap.
◆ Check to see whether there is any obstacle adversely affecting
the flow of the air inside and outside the room.
- Remove the obstacle or change the position of the air conditioner.
◆ Check to see whether the air filter is clogged with dust or
contaminated with foreign substances.
- Clean the air filter.
◆ Check to see whether there is any direct sunlight facing the air conditioner.
- Block the sunlight with a sunshade.
◆ Check to see whether there is any electric device generating heat.
- Do not use the air conditioner together with any heating device.
Odors are permeating the
room during air conditioning.
◆ Ventilate the room.
AW05MOYEA_E/O_08574
12/12/02 4:24 PM
Page 11
Technical Specifications
Design and specifications are subject to change without notice.
Model
AW05N0YAD
AW05N0YAH
Power Supply
115V~, 60Hz
E-11
AW05MOYEA_E/O_08574
12/12/02 4:24 PM
Page 12
Installation
Before installation, be sure to check the installation area or the air
conditioner, and drain hose.
Checkpoints prior to installation
1 Check the cabinet and front grille of the unit for any harmful defects
such as scratches.
2 Be sure to check the power supply.
- Refer to the specifications on the label attached to the unit.
Installation Conditions
1 As the unit is heavy, the wall or window of the installation area should
have sufficient strength and durability for operation of the air conditioner,
and for prevention of any vibration or noise.
If it is weak, reinforcement work should be performed separately.
2 It is advisable to install the air conditioner in the north or west side to
prevent the effect of direct sunlight.
When installing it in the south or east side due to unavoidable
circumstances, it is advisable to install the sunshade to prevent the
direct sunlight.
In this case, take care not to cause any hindrance to the flow of outside air.
3 When installing the air conditioner, be sure to obtain sufficient space on
the rear side of the unit for smooth flow of air.
When operating the air conditioner in closed areas such as inner building
with cooling operation, and result in trouble with the unit.
See the illustration below.
Awning
30mm
min.
OFF
Jmu �D_l
5
F g�D_l
6
4
7
3
8
2
Jmu �Ammj
F g�Ammj
300mm
9
1
10
K cb�Ammj
Selector
Thermostat
110mm
500mm
500mm
500mm
Fence, wall
or other
obstacle
Approx.3˚
750mm
➢
110mm min.
◆ If the wall is greater than 110mm thick,
cut the wall back on a 45˚ angle if possible.
Outdoor side
Indoor side
100mm or more
E-12
45˚
45˚
AW05MOYEA_E/O_08574
12/12/02 4:24 PM
Page 13
Install an adhesive bottom gasket to prevent air and insects from getting
into the room.
1
Strip an adhesive bottom gasket off.
2
Seal an adhesive bottom gasket to the bottom of the air conditioner.
Adhesive bottom
gasket
Installation of the Drain Tube
Rear
Fix the drain tube as shown in the figure.
Rubber cap
Gasket
Drain Tube
Screws(2EA)
E-13
AW05MOYEA_E/O_08574
12/12/02 4:24 PM
Page 14
THIS AIR CONDITIONER IS MANUFACTURED BY:
ELECTRONICS