Samsung | AR19MSSSDWKXHC | Samsung AR25MSSSDWKXHC User Manual

QUESTIONS OR COMMENTS?
COUNTRY
CALL
OR VISIT US ONLINE AT
IRAN
021-8255
SAUDI ARABIA
800 247 3457 (800 24/7 HELP)
U.A.E
800-SAMSUNG
(800 - 726 7864)
QATAR
800-CALL (800-2255)
BAHRAIN
8000-GSAM (8000-4726)
www.samsung.com/iran/support
www.samsung.com/sa/home
www.samsung.com/sa_en
www.samsung.com/ae/support (English)
www.samsung.com/ae_ar/support (Arabic)
www.samsung.com/ae/support (English)
www.samsung.com/ae_ar/support (Arabic)
www.samsung.com/ae/support (English)
www.samsung.com/ae_ar/support (Arabic)
www.samsung.com/ae/support (English)
www.samsung.com/ae_ar/support (Arabic)
MOROCCO
800-SAMSUNG
(800 - 726 7864)
0800-22273
06 5777444
962 5777444
961 1484 999
1299
08000-7267864
16580
080 100 22 55
KUWAIT
183-CALL (183-2255)
NIGERIA
ALGERIA
PAKISTAN
TUNISIA
SOUTH AFRICA
GHANA
BOTSWANA
NAMIBIA
ZAMBIA
0800-726-7864
3004 (Toll Free)
0800-Samsung (72678)
80 1000 12
0860 SAMSUNG (726 7864)
0800-100077
8007260000
08 197 267 864
0211 350370
OMAN
JORDAN
SYRIA
LEBANON
EGYPT
DB68-06028A-01_A5.indd 32
www.samsung.com/levant
www.samsung.com/levant
www.samsung.com/levant/support
www.samsung.com/eg/support
www.samsung.com/n_africa/support
www.samsung.com/ae/support (English)
www.samsung.com/ae_ar/support (Arabic)
www.samsung.com/africa_en/support
www.samsung.com/n_africa/support
www.samsung.com/pk/support
www.samsung.com/n_africa/support
www.samsung.com/support
www.samsung.com/africa_en/support
www.samsung.com/support
www.samsung.com/support
www.samsung.com/support
2/20/2017 5:28:48 PM
Air conditioner
User manual/Installation manual
AR✴✴KSSS✴✴, AR✴✴MSSS✴✴
•• Thank you for purchasing this Samsung air conditioner.
•• Before operating this unit, please read this installation manual carefully and retain it for future
reference.
DB68-06028A-01
DB68-06028A-01_A5.indd 1
2/20/2017 5:28:49 PM
Contents
Safety Information 4
Safety Information
4
At a Glance
9
Indoor Unit Overview
Display
9
Remote Control Overview
Inserting batteries
10
Remote Control Operation
Operation modes • Controlling temperature •
Controlling fan speed • Controlling air flow direction
11
Power Smart Features
13
Cooling Operation
Cool mode • 2-Step cooling function
13
Dehumidifying Operation
Dry mode
14
Air Purifying Operation
Virus doctor function
15
Heating Operation
Heat mode
16
Quick Smart Features
Auto mode • Fan mode • Fast function • Comfort function •
Quiet function • Beep sound function
17
Energy-Saving Features
21
Energy-Saving Operation
Single user function • Timed on/Timed off function • good’sleep function
21
Cleaning and Maintenance
24
Cleaning at a Glance
24
Troubleshooting26
Installation28
Safety Information on Installation
28
Preparation30
Step 1.1 Choosing the installation location
Step 1.2 Unpacking
Step 1.3 Checking and preparing accessories and tools
Step 1.4 Drilling a hole through the wall
Step 1.5 Taping the pipes, cables, and drain hose
2 English
DB68-06028A-01_A5.indd 2
2/20/2017 5:28:50 PM
Indoor Unit Installation
Step 2.1 Disassembling the cover panel
Step 2.2 Disassembling the installation plate
Step 2.3 Connecting the power and communication cables (assembly cable)
Step 2.4 Optional: Extending the power cable
Step 2.5 Installing and connecting the drain hose
Step 2.6 Optional: Extending the drain hose
Step 2.7 Optional: Changing the direction of the drain hose
Step 2.8 Installing and connecting the assembly pipes to the refrigerant pipes (assembly pipe)
Step 2.9 Shortening or extending the refrigerant pipes (assembly pipe)
Step 2.10 Fixing the installation plate
Step 2.11 Fixing the indoor unit to the installation plate
Step 2.12 Assembling the cover panel
34
Outdoor Unit Installation
Step 3.1 Fixing the outdoor unit in place
Step 3.2 Connecting the power and communication cables and the refrigerant pipes
Step 3.3 Evacuating the air
Step 3.4 Adding refrigerant
42
Installation Inspection
Step 4.1 Performing the gas leak tests
Step 4.2 Running the Smart Install mode
Step 4.3 Performing final check and trial operation
45
Correct Disposal of This Product
(Waste Electrical & Electronic Equipment)
(Applicable in countries with separate collection systems)
This marking on the product, accessories or literature indicates that the product and its electronic accessories (e.g.
charger, headset, USB cable) should not be disposed of with other household waste at the end of their working life. To
prevent possible harm to the environment or human health from uncontrolled waste disposal, please separate these
items from other types of waste and recycle them responsibly to promote the sustainable reuse of material resources.
Household users should contact either the retailer where they purchased this product, or their local government office,
for details of where and how they can take these items for environmentally safe recycling.
Business users should contact their supplier and check the terms and conditions of the purchase contract. This product
and its electronic accessories should not be mixed with other commercial wastes for disposal.
Correct disposal of batteries in this product
This marking on the battery, manual or packaging indicates that the batteries in this product should not be disposed of
with other household waste at the end of their working life. Where marked, the chemical symbols Hg, Cd or Pb indicate
that the battery contains mercury, cadmium or lead above the reference levels in EC Directive 2006/66.
English 3
DB68-06028A-01_A5.indd 3
2/20/2017 5:28:51 PM
Safety Information
Before using your new air conditioner, please read this manual thoroughly to ensure that you know how to
safely and efficiently operate the extensive features and functions of your new appliance.
Safety Information
Because the following operating instructions cover various models, the characteristics of your air conditioner
may differ slightly from those described in this manual. If you have any questions, call your nearest contact
centre or find help and information online at www.samsung.com.
WARNING
Hazards or unsafe practices that may result in severe personal injury or death.
CAUTION
Hazards or unsafe practices that may result in minor personal injury or property damage.
Follow directions.
Do NOT attempt.
Make sure the machine is grounded to prevent electric shock.
Cut off the power supply.
Do NOT disassemble.
FOR INSTALLATION
WARNING
Use a power cord with this product's power specifications or higher and use the power cord for this
appliance only. In addition, do not use an extension cord.
• Extending the power cord may result in electric shock or fire.
• Do not use an electric transformer. This may result in electric shock or fire.
• If the voltage/frequency/rated current condition is different, it may cause fire.
The installation of this appliance must be performed by a qualified technician or service company.
• Failing to do so may result in electric shock, fire, explosion, problems with the product, or injury and
may also void warranty on the installed product.
Install an Isolation Switch next to the Air Conditioner (but not on the panels of the Air Conditioner) and
circuit breaker dedicated to the air conditioner.
• Failing to do so may result in electric shock or fire.
Fix the outdoor unit firmly so that the electric part of the outdoor unit is not exposed.
• Failing to do so may result in electric shock, fire, explosion, or problems with the product.
Do not install this appliance near a heater, or inflammable material. Do not install this appliance in a
humid, oily or dusty location, in a location exposed to direct sunlight and water (or rain). Do not install
this appliance in a location where gas may leak.
• This may result in electric shock or fire.
Never install the outdoor unit in a location such as on a high external wall where it could fall.
4 English
DB68-06028A-01_A5.indd 4
2/20/2017 5:28:55 PM
• If the outdoor unit falls, it may result in injury, death or property damage.
• Failing to do so may result in electric shock, fire, and explosion.
• Make sure to use a socket-outlet with ground.
CAUTION
Install your appliance on a level and hard floor that can support its weight.
Safety Information
This appliance must be properly grounded. Do not ground the appliance to a gas pipe, plastic water pipe,
or telephone line.
• Failing to do so may result in abnormal vibrations, noise, or problems with the product.
Install the drain hose properly so that water drains correctly.
• Failing to do so may result in water overflowing and property damage. Avoid adding drain to waste
pipes as odours may arise in the future.
When installing the outdoor unit, make sure to connect the drain hose so that draining is performed
correctly.
• The water generated during heating by the outdoor unit may overflow and result in property
damage.
In particular, in winter, if a block of ice falls, it may result in injury, death or property damage.
FOR POWER SUPPLY
WARNING
When the circuit breaker is damaged, contact your nearest service centre.
Do not pull or excessively bend the power line. Do not twist or tie the power line. Do not hook the
power line over a metal object, place a heavy object on the power line, insert the power line between
objects, or push the power line into the space behind the appliance.
• This may result in electric shock or fire.
CAUTION
When not using the air conditioner for a long period of time or during a thunder/lightning storm, cut
the power at the circuit breaker.
• Failing to do so may result in electric shock or fire.
FOR USING
WARNING
If the appliance is flooded, please contact your nearest service centre.
• Failing to do so may result in electric shock or fire.
English 5
DB68-06028A-01_A5.indd 5
2/20/2017 5:28:55 PM
If the appliance generates a strange noise, a burning smell or smoke, cut off the power supply
immediately and contact the nearest service centre.
Safety Information
• Failing to do so may result in electric shock or fire.
In the event of a gas leak (such as propane gas, LP gas, etc.), ventilate immediately without touching
the power line. Do not touch the appliance or power line.
• Do not use a ventilating fan.
• A spark may result in an explosion or fire.
To reinstall the air conditioner, please contact your nearest service centre.
• Failing to do so may result in problems with the product, water leakage, electric shock, or fire.
• Delivery service for the product is not provided. If you reinstall the product in another location,
additional construction expenses and an installation fee will be charged.
• Especially, when you wish to install the product in an unusual location such as in an industrial area or
near the seaside where it is exposed to salt in the air, please contact your nearest service centre.
Do not touch the circuit breaker with wet hands.
• This may result in electric shock.
Do not turn the air conditioner off with the circuit breaker while it is operating.
• Turning the air conditioner off and then on again with the circuit breaker may cause a spark and
result in electric shock or fire.
After unpacking the air conditioner, keep all packaging materials well out of the reach of children, as
packaging materials can be dangerous to children.
• If a child places a bag over its head, it may result in suffocation.
Do not touch the air flow blade with your hands or fingers during heating.
• This may result in electric shock or burns.
Do not insert your fingers or foreign substances into the air inlet/outlet of the air conditioner.
• Take special care that children do not injure themselves by inserting their fingers into the product.
Do not strike or pull the air conditioner with excessive force.
• This may result in fire, injury, or problems with the product.
Do not place an object near the outdoor unit that allows children to climb onto the machine.
• This may result in children seriously injuring themselves.
Do not use this air conditioner for long periods of time in badly ventilated locations or near infirm
people.
• Since this may be dangerous due to a lack of oxygen, open a window at least once an hour.
If any foreign substance such as water has entered the appliance, cut off the power supply and contact
the nearest service centre.
• Failing to do so may result in electric shock or fire.
Do not attempt to repair, disassemble, or modify the appliance yourself.
6 English
DB68-06028A-01_A5.indd 6
2/20/2017 5:28:56 PM
CAUTION
Do not place objects or devices under the indoor unit.
• Water dripping from the indoor unit may result in fire or property damage.
Check that the installation frame of the outdoor unit is not broken at least once a year.
• Failing to do so may result in injury, death or property damage.
• To prevent personal injury, make sure that you change the directions of the horizontal air flow blades
after stopping the movements of the vertical air flow blade.
Safety Information
• Do not use any fuse (such as cooper, steel wire, etc.) other than the standard fuse.
• Failing to do so may result in electric shock, fire, problems with the product, or injury.
Max current is measured according to IEC standard for safety and current is measured according to ISO
standard for energy efficiency.
Do not stand on top of the appliance or place objects (such as laundry, lighted candles, lighted
cigarettes, dishes, chemicals, metal objects, etc.) on the appliance.
• This may result in electric shock, fire, problems with the product, or injury.
Do not operate the appliance with wet hands.
• This may result in electric shock.
Do not spray volatile material such as insecticide onto the surface of the appliance.
• As well as being harmful to humans, it may also result in electric shock, fire or problems with the
product.
Do not drink the water from the air conditioner.
• The water may be harmful to humans.
Do not apply a strong impact to the remote control and do not disassemble the remote control.
Do not touch the pipes connected with the product.
• This may result in burns or injury.
Do not use this air conditioner to preserve precision equipment, food, animals, plants or cosmetics, or
for any other unusual purposes.
• This may result in property damage.
Avoid directly exposing humans, animals or plants to the air flow from the air conditioner for long
periods of time.
• This may result in harm to humans, animals or plants.
This appliance is not intended for use by persons (including children) with reduced physical, sensory
or mental capabilities, or lack of experience and knowledge, without supervision or instruction
concerning use of the appliance by a person responsible for their safety. Children should be supervised
to ensure that they do not play with the appliance.
English 7
DB68-06028A-01_A5.indd 7
2/20/2017 5:28:56 PM
FOR CLEANING
Safety Information
WARNING
Do not clean the appliance by spraying water directly onto it. Do not use benzene, thinner or alcohol to
clean the appliance.
• This may result in discolouration, deformation, damage, electric shock or fire.
Before cleaning or performing maintenance, cut off the power supply and wait until the fan stops.
• Failing to do so may result in electric shock or fire.
CAUTION
Take care when cleaning the surface of the heat exchanger of the outdoor unit since it has sharp edges.
• This should be done by a qualified technician. Please contact your installer or service centre.
Do not clean the inside of the air conditioner by yourself.
•
•
•
•
For cleaning inside the appliance, contact your nearest service centre.
When cleaning the filter, refer to the descriptions in the ‘Cleaning at a Glance’ section.
Failing to do so may result in damage, electric shock or fire.
Make sure to prevent any injury from sharp edges of the surface when handling the heat exchanger.
8 English
DB68-06028A-01_A5.indd 8
2/20/2017 5:28:57 PM
Indoor Unit Overview
The actual product may differ slightly from the image depicted below.
05
01
02
At a Glance
06
07
03
04
08
01 Air intake
06 Display
02 Air filter
07 Power button /
Remote control receiver
03 Air flow blade (up and down)
04 Air flow blade (left and right)
08 (Inside) Virus doctor
05 Room temperature sensor
Display
01 Operation indicator
01
02
02 Timer indicator
good'sleep indicator
Auto clean indicator
03 Virus doctor indicator
03
English 9
DB68-06028A-01_A5.indd 9
2/20/2017 5:29:03 PM
Remote Control Overview
01 Set temperature indicator
05
01
02
03 Operation mode indicator
06
04 Options indicator
07
05 Low battery indicator
08
03
02 Timer option indicator
06 Transmit indicator
07 Fan speed indicator
04
At a Glance
08 Vertical air swing indicator
10
09
09 Settings indicator
15
10 Power button
16
11 Temperature button
12 Options button
13 Timer button
11
17
14 Direction button / Selection button
15 Vertical air swing button
12
18
19
13
16 Mode button
17 Fan speed button
18 Single user button
19 Settings button
20 SET button
20
14
Inserting batteries
NOTE
• The descriptions in this manual are primarily
made based on the remote control buttons.
• Although d'light Cool, Usage, Filter Reset, Display
is displayed on the remote control display, it is
not available on this model.
two 1.5V AAA type batteries
10 English
DB68-06028A-01_A5.indd 10
2/20/2017 5:29:04 PM
Remote Control Operation
You can use the air conditioner easily by selecting a mode and then by controlling the temperature, fan speed,
and air direction.
Operation modes
You can change the current mode between Auto, Cool, Dry, Fan, and
Heat by pressing the
button.
Controlling temperature
You can control the temperature in each mode as follows:
At a Glance
Mode
Temperature control
Auto/Cool/
Heat
Adjust by 1 °C between 16 °C and 30 °C.
Dry
Adjust by 1 °C between 18 °C and 30 °C.
Fan
You cannot control the temperature.
NOTE
You can use the Cool, Dry, and Heat modes in the following conditions:
Mode
Cool
Dry
Heat
Indoor
temperature
16 °C to 32 °C
18 °C to 32 °C
27 °C or less
Outdoor
temperature
-10 °C to 46 °C
-10 °C to 46 °C
-15 °C to 24 °C
Indoor humidity
80% or less
relative
humidity
_
_
• If the air conditioner operates in a high humidity environment in the
Cool mode for an extended period of time, condensation may occur.
• If the outdoor temperature drops to -15°C, the heating capacity may
decrease to as much as 60% to 70% of the specified capacity.
English 11
DB68-06028A-01_A5.indd 11
2/20/2017 5:29:06 PM
Controlling fan speed
You can select the following fan speeds in each mode:
Mode
Available fan speeds
At a Glance
Auto/Dry
(Auto)
Cool/Heat
(Auto),
(Turbo)
Fan
(Low),
(Low),
(Med),
(High),
(Med),
(High),
(Turbo)
Controlling air flow direction
Vertical air flow
Keep the vertical air flow in a constant direction by stopping the
movements of the vertical air flow blade.
In operation
►
NOTE
• If you adjust the vertical air flow blade manually, it may not close
completely when you turn off the air conditioner.
• You can control the vertical air flow direction when the good'sleep
function is running while in the Heat mode, but not while in the
Cool mode.
Horizontal air flow (manual)
Keep the horizontal air flow in a constant direction by changing the
directions of the horizontal air flow blades manually.
12 English
DB68-06028A-01_A5.indd 12
2/20/2017 5:29:10 PM
Cooling Operation
The smart and powerful cooling functions of the Samsung air conditioner keep an enclosed space cool and
comfortable.
Cool mode
Use the Cool mode to stay cool in hot weather.
►
► Select Cool.
NOTE
• For comfort, keep the temperature difference between the indoor
and outdoor air within 5 °C in the Cool mode.
• After selecting the Cool mode, select a function, temperature, and
fan speed that you want to apply.
–– To save energy, select a high temperature and a weak fan speed.
–– As the indoor temperature approaches the set temperature, the
compressor will operate at a low speed to save energy.
2-Step cooling function
Power Smart Features
–– To cool your room quickly, select a low temperature and a strong
fan speed.
Use the 2-Step cooling function to quickly reach the set temperature.
The air conditioner automatically adjusts the fan speed and air flow
direction. You can select this function only when the Cool mode is
running.
In the Cool mode ►
►
►
Select 2-Step. ►
English 13
DB68-06028A-01_A5.indd 13
2/20/2017 5:29:12 PM
Dehumidifying Operation
The dehumidifying function of the Samsung air conditioner keeps an enclosed space dry and comfortable.
Dry mode
Use the Dry mode in rainy or humid weather.
►
► Select Dry.
NOTE
• The lower the set temperature is, the greater the dehumidifying
capacity is. When the current humidity seems to be high, adjust the
set temperature to a low temperature.
• You cannot use the Dry mode for heating. The Dry mode is designed
to produce a cooling side-effect.
Power Smart Features
14 English
DB68-06028A-01_A5.indd 14
2/20/2017 5:29:14 PM
Air Purifying Operation
The air purification function of the Samsung air conditioner keeps the air in an enclosed space purified.
Virus doctor function
Use the Virus doctor function to purify your room with negative ions
produced by the air conditioner. This function is available in the Auto,
Cool, Dry, Fan, and Heat modes.
In the Auto, Cool, Dry, Fan,
►
or Heat mode
Select
►
►
. ►
NOTE
• You can adjust the set temperature, except for in the Fan mode.
Power Smart Features
• When the Virus doctor function is additionally selected while a
specific mode is running, there is little difference in electricity
consumption and operating noise.
English 15
DB68-06028A-01_A5.indd 15
2/20/2017 5:29:15 PM
Heating Operation
The heating functions of the Samsung air conditioner keep an enclosed space warm and comfortable.
Heat mode
Use the Heat mode to stay warm.
►
► Select Heat.
NOTE
• While the air conditioner warms up, the fan may not operate for
about 3 to 5 minutes at the beginning to prevent cold blasts.
• If the air conditioner heats insufficiently, use an additional heating
appliance in combination with the air conditioner.
Power Smart Features
• When the outdoor temperature is low and the humidity is high
in Heat mode, frost may develop on the outdoor heat exchanger.
This may also decrease the heating efficiency. If this occurs, the air
conditioner runs the defrost function for 5 to 12 minutes to remove
frost from the outdoor heat exchanger.
• When the defrost function is running, steam is produced on the
outdoor unit. The air conditioner moves the vertical air flow blade to
the lowest position, as shown in the left figure, to prevent cold air
from coming out from the indoor unit.
B
A
A.The position of the vertical air flow blade when the defrost function
is running (The blade looks almost closed.)
B.The position range of the vertical air flow blade when the Heat
mode is running.
• When the defrost function is running, no air comes out from the
indoor unit in order to prevent cold air from coming out. When the
defrost function is finished, warm air comes out after a while.
• The cycle of the defrost function may be shortened depending on
the amount of frost on the outdoor unit.
• The cycle of the defrost function may be shortened depending on
the humidity from rain and snow, too.
• When the defrost function is running, you cannot select other
functions with the remote control. Select them after the defrost
function is finished.
16 English
DB68-06028A-01_A5.indd 16
2/20/2017 5:29:17 PM
Quick Smart Features
There is a variety of extra functionality provided by the Samsung air conditioner.
Auto mode
Use the Auto mode when you want the air conditioner to automatically
control the operation. The air conditioner will provide the most
comfortable atmosphere that it can.
►
► Select Auto.
NOTE
Fan mode
Use the Fan mode to run the air conditioner like a common fan. The air
conditioner provides a natural breeze.
►
Power Smart Features
• When the indoor temperature seems to be higher or lower than the
set point, the air conditioner automatically produces either cool air
to cool down the indoor temperature or warm air to warm up the
indoor temperature.
► Select Fan.
NOTE
• If the air conditioner will not be used for an extended period of time,
dry the air conditioner by running it in the Fan mode for 3 or 4 hours.
• The outdoor unit is designed not to operate in the Fan mode to
prevent cold air from entering through the unit. This is a normal
operation and not a fault with the air conditioner.
English 17
DB68-06028A-01_A5.indd 17
2/20/2017 5:29:18 PM
Fast function
Use the Fast function to quickly cool or heat your room. This function
is the most powerful cooling and heating function provided by the
air conditioner. You can select this function both in the Cool and Heat
modes.
In the Cool or Heat mode ►
►
►
Select Fast ►
Power Smart Features
NOTE
• If you select the Fast function while such functions as 2-Step
cooling, Comfort, Single user, Quiet, or good'sleep are running,
these functions are cancelled.
• You can change the air flow direction.
• You cannot change the set temperature and the fan speed.
• When you select the Fast function in the Heat mode, you may not
be able to increase the fan speed in order to prevent cool air from
blowing.
18 English
DB68-06028A-01_A5.indd 18
2/20/2017 5:29:18 PM
Quick Smart Features
Comfort function
Use the Comfort function when you feel the current cooling or heating
effect is too strong. The air conditioner provides a mild cooling or
heating. You can select this function both in the Cool and Heat modes.
In the Cool or Heat mode ►
►
►
Select Comfort. ►
NOTE
• You cannot change the fan speed.
• If you select the Comfort function while such functions as 2-Step
cooling, Fast, Single user, Quiet, or good'sleep are running, these
functions are cancelled.
• If you feel cooling or heating effect in the Comfort function is weak,
cancel the Comfort function.
Power Smart Features
• You can change the set temperature and the air flow direction.
Quiet function
Use the Quiet function to reduce operating noise. You can select this
function both in the Cool and Heat modes.
In the Cool or Heat mode ►
►
►
Select Comfort. ►
NOTE
• You can change the set temperature and the air flow direction.
• You cannot change the fan speed.
• If you select the Quiet function while such functions as 2-Step
cooling, Fast, Comfort, Single user, or good'sleep are running, these
functions are cancelled.
English 19
DB68-06028A-01_A5.indd 19
2/20/2017 5:29:21 PM
Beep sound function
Use the Beep sound function to turn on or off the beep sound that plays
when you press a button on the remote control.
►
► Select Beep. ►
Power Smart Features
20 English
DB68-06028A-01_A5.indd 20
2/20/2017 5:29:23 PM
Energy-Saving Operation
The smart energy-saving functions of the Samsung air conditioner reduce electricity consumption.
Single user function
Use the Single user function to reduce electricity consumption while
staying cool or warm. You can select this function in the Cool and Heat
modes.
In the Cool or Heat mode ►
NOTE
pattern
• When the Single user function starts, the
appears on the remote control for a few seconds, and vertical air
swing begins automatically.
• If you select the Single user while such function as 2-Step cooling,
Fast, Comfort, Quiet, or good'sleep are running, these modes are
cancelled.
• When the Single user function is turned on in the Cool mode while
the set temperature is set to lower than 24 °C, the set temperature
is automatically raised to 24 °C. But if the set temperature is set to
between 25 °C and 30 °C, it remains the same.
• Even after you turn off the Single user function, vertical air swing
continues until you turn it off with the Vertical air swing (
)
button.
• You can also start the Single user function by pressing the Options (
) button.
In the Cool or Heat mode ►
►
Energy-Saving Features
• After selecting the Single user function, you can change the set
temperature (24 °C to 30 °C in the Cool mode, 16 °C to 30 °C in the
Heat mode), fan speed, and vertical air flow direction.
►
Select Single user. ►
English 21
DB68-06028A-01_A5.indd 21
2/20/2017 5:29:25 PM
Timed on/Timed off function
Use the Timed on/Timed off to turn on or off the air conditioner after
the time that you set.
(Select On or Off among On, Off, and
.) ►
(Set the on/off time.) ►
• Press the
(Timer) button to change the current function
between On, Off, and
(good’sleep).
(good’sleep) is displayed
in the Cool and Heat modes only.
NOTE
• You can set a time between 0.5 and 24 hours. Set the time interval
to 0.0 to cancel the Timed on/off function.
Energy-Saving Features
• Once you start the Timed on/off function, the Timer (
displayed on the indoor unit display.
) indicator is
• After starting the Timed on function, you can change the mode and
the set temperature. You cannot change the set temperature while
the Fan mode is running.
• You cannot set the same time for both of the Timed on and Timed
off functions.
Combining Timed on and Timed off
Example) Timed on: 3 hours, Timed off: 5 hours
When the air
conditioner The air conditioner turns on after 3 hours from the
moment you start Timed on/off, remains on for 2
is off
hours, then turns off automatically.
Example) Timed on: 3 hours, Timed off: 1 hour
When the air
conditioner The air conditioner turns off after 1 hour from the
moment you start Timed on/off, then turns on after 2
is on
hours from the moment it is turned off.
22 English
DB68-06028A-01_A5.indd 22
2/20/2017 5:29:26 PM
good’sleep function
Use the good'sleep function to get a good sleep at night and to save
energy. You can select this function both in the Cool and Heat modes.
In the Cool or
►
Heat mode
(Select
.) ►
among On, Off, and
(Set the operation time.) ►
• Press the
(Timer) button to change the current function
between On, Off, and
(good’sleep).
NOTE
• You can adjust the set temperature by 1 °C between 16 °C and 30 °C.
Mode
Recommended set
temperature
Optimal set
temperature
Cool
25 °C to 27 °C
26 °C
Heat
21 °C to 23 °C
22 °C
• Once you start the good’sleep function, the Timer (
appears on the indoor unit display.
) indicator
Energy-Saving Features
• The recommended and optimal set temperatures in the good’sleep
function are as follows:
• You can set the operation time to between 0.5 and 12 hours. Set the
operation time to 0.0 to cancel the good’sleep function.
• The default operation time for the good’sleep function in the
Cool mode is 8 hours. If the operation time is set to over 5 hours,
the Wake up function begins 1 hour before the set time. The air
conditioner stops automatically when the operation time expires.
• When the Timed on, Timed off, and good'sleep functions are
overlapped, the air conditioner operates its timer with only the
function that you have started most recently.
English 23
DB68-06028A-01_A5.indd 23
2/20/2017 5:29:28 PM
Cleaning at a Glance
Running Auto clean
Cleaning duration (minutes)
Auto (Cool), Cool, Dry
30
Auto (Heat), Heat, Fan
15
NOTE
• When you set the Auto clean timer, Clean blinks and then disappears on the remote control display. The
Timer ( ) indicator also appears on the indoor unit display.
• When the air conditioner is off, Auto clean starts immediately when it is selected. When the air conditioner
is on, Auto clean starts as soon as the air conditioner stops running.
• During Auto clean, the indoor fan continues to run, and air flow blades remain open to expel ambient air.
Cleaning the indoor unit exterior and outdoor unit heat exterior
Cleaning and Maintenance
Tepid damp cloth
Soft brush
Before cleaning, be sure to turn off the equipment
and disconnect the power plug.
Spray water to clean the dust.
CAUTION
• Do not clean the display by using alkaline detergent.
• Do not use sulphuric acid, hydrochloric acid, or organic solvents (such as thinner, kerosene, and acetone) to
clean the surfaces. Do not put any stickers on it as this can damage the surface of the air conditioner
• When you clean and inspect the heat exchanger on the outdoor unit, contact the local service centre for
help.
24 English
DB68-06028A-01_A5.indd 24
2/20/2017 5:29:30 PM
Cleaning the filter
Vacuum cleaner
Soft brush
30 minutes
Hooks
Mild detergent
CAUTION
• Do not scrub the air filter with a brush or other cleaning utensil. This may damage the filter.
• Do not expose the air filter to direct sunlight when drying it.
NOTE
• Clean the air filter every 2 weeks. Cleaning term may vary depending on the usage and environmental
conditions.
• If the air filter dries in a humid area, it may produce offensive odours. Clean it again and dry it in a wellventilated area.
Cleaning and Maintenance
English 25
DB68-06028A-01_A5.indd 25
2/20/2017 5:29:31 PM
Troubleshooting
If the air conditioner operates abnormally, refer to the following chart to save time and unnecessary expenses.
Problem
Solution
• Check the power status, then operate the air conditioner again.
The air conditioner does
not work at all.
• Switch on the circuit breaker, plug in the power cord, then operate the air
conditioner again.
• Make sure that the isolator is turned on.
• Check whether the Timed off function is running. Operate the air
conditioner again by pressing the Power button.
I cannot change the
temperature.
• Check whether the Fan or Fast mode is running. In these modes, the air
conditioner controls the set temperature automatically, and you cannot
change the set temperature.
• Check whether the set temperature is higher in the Cool mode or lower
in the Heat mode than the current temperature. Press the Temperature
button on the remote control to change the set temperature.
• Check whether the air filter is blocked with dirt. If the air filter is blocked,
the cooling and heating performance may decrease. Remove dirt regularly.
• Check whether the outdoor unit is covered or installed near obstacles.
Remove the coverings and obstacles.
Cool or warm air does
not come out of the air
conditioner.
• Check whether the air conditioner is running the defrost function. When ice
forms in winter or the outdoor temperature is too low, the air conditioner
runs the defrost function automatically. While this function is running, the
indoor fan stops and warm air does not come out.
Cleaning and Maintenance
• Check whether doors or windows are open. This may cause poor cooling or
heating performance. Close the doors and windows.
• Check whether the air conditioner is turned on immediately after the
cooling or heating operation stops. In this case, only the fan runs to protect
the outdoor unit compressor.
• Check whether the pipe length is too long. When the pipe length exceeds
the maximum pipe length, the cooling and heating performance may
decrease.
I cannot change the air flow
direction.
• Check whether the good'sleep function is running. While this function is
running, you cannot control the air flow direction. (But you can control the
air flow direction if this function is running in the Heat mode.)
26 English
DB68-06028A-01_A5.indd 26
2/20/2017 5:29:32 PM
Problem
I cannot change the fan
speed.
Solution
• When the Auto, Dry, or Fast mode is running or the good'sleep function
is running in the Cool mode, the air conditioner controls the fan speed
automatically and you cannot change the fan speed.
• Replace the batteries in the remote control with new ones.
The remote control does
not work.
• Make sure that nothing is blocking the remote control sensor.
• Check whether there are strong lighting apparatus near the air
conditioner. Strong light which comes from fluorescent bulbs or neon
signs may interrupt the electric waves.
The Timed on/off function
does not work.
• Check whether you pressed the SET button on the remote control after
setting the time.
The indicator blinks
continuously.
• Press the Power button to turn off the air conditioner or disconnect the
power plug. If the indicator is still blinking, contact the service centre.
Odours permeate in the
room during operation.
• Check whether the air conditioner is running in a smoky area. Ventilate
the room or operate the air conditioner in the Fan mode for 3 to 4 hours.
(There are no components used in the air conditioner that emit a strong
odour.)
• Check whether the drains are clean. Clean them regularly.
• If the indoor unit indicator blinks, contact the nearest service centre. Be
sure to pass the error code to the service centre.
Noise is generated.
• When refrigerant flow changes, noise may be generated, depending on
the status of the air conditioner. This is a normal operation.
Smoke is generated from
the outdoor unit.
• If may not be a fire but it can be a steam generated from the outdoor
heat exchanger while the defrost function is running in the Heat mode
in winter.
Water drops from the pipe
connections of the outdoor
unit.
• Condensation may develop when the ambient temperature changes
excessively. This is a normal operation.
Cleaning and Maintenance
An error is indicated.
English 27
DB68-06028A-01_A5.indd 27
2/20/2017 5:29:32 PM
Safety Information on Installation
Carefully follow the precautions listed below because
they are essential to guarantee the safety of both the
air conditioner and the workers.
• Always disconnect the air conditioner from the
power supply before servicing it or accessing its
internal components.
• In order to help prevent electric shocks, fires
or injuries, always stop the unit, disable the
protection switch and contact SAMSUNG’s
technical support if the unit produces smoke, if
the power cable is hot or damaged or if the unit is
very noisy.
• Verify that installation and testing operations are
performed by qualified personnel.
• Always remember to inspect the unit, electric
connections, refrigerant tubes and protections
regularly. These operations should be performed
by qualified personnel only.
• Verify that the air conditioner is not installed in an
easily accessible area.
• The unit contains moving parts, which should
always be kept out of the reach of children.
General information
• Do not attempt to repair, move, alter or reinstall
the unit. If performed by unauthorised personnel,
these operations may cause electric shocks or
fires.
• Carefully read the content of this manual before
installing the air conditioner and store the manual
in a safe place in order to be able to use it as
reference after installation.
• For maximum safety, installers should always
carefully read the following warnings.
• Store the operation and installation manual in
a safe location and remember to hand it over to
the new owner if the air conditioner is sold or
transferred.
• This manual explains how to install an indoor unit
with a split system with two SAMSUNG units. The
use of other types of units with different control
systems may damage the units and invalidate
the warranty. The manufacturer shall not be
responsible for damages arising from the use of
non compliant units.
• This product has been determined to be in
compliance with the Low Voltage Directive
(2006/95/EC) and the Electromagnetic
Compatibility Directive (2004/108/EC) of the
European Union.
Installation
• The manufacturer shall not be responsible for
damage originating from unauthorised changes
or the improper connection of electric and
requirements set forth in the “Operating limits”
table, included in the manual, shall immediately
invalidate the warranty.
• The air conditioner should be used only for the
applications for which it has been designed: the
indoor unit is not suitable to be installed in areas
used for laundry.
• Do not use the units if damaged. If problems
occur, switch the unit off and disconnect it from
the power supply.
• Do not place containers with liquids or other
objects on the unit.
• All the materials used for the manufacture and
packaging of the air conditioner are recyclable.
• The packing material and exhaust batteries of the
remote control (optional) must be disposed of in
accordance with current laws.
• The air conditioner contains a refrigerant that has
to be disposed of as special waste. At the end of
its life cycle, the air conditioner must be disposed
of in authorised centres or returned to the retailer
so that it can be disposed of correctly and safely.
Installation of the unit
• IMPORTANT: When installing the unit, always
remember to connect first the refrigerant tubes,
then the electrical lines. Always disassemble the
electric lines before the refrigerant tubes.
• Upon receipt, inspect the product to verify that
it has not been damaged during transport. If
the product appears damaged, DO NOT INSTALL
it and immediately report the damage to the
carrier or retailer (if the installer or the authorised
technician has collected the material from the
retailer.)
• After completing the installation, always carry out
a functional test and provide the instructions on
how to operate the air conditioner to the user.
• Do not use the air conditioner in environments
with hazardous substances or close to equipment
that release free flames to avoid the occurrence of
fires, explosions or injuries.
28 English
DB68-06028A-01_A5.indd 28
2/20/2017 5:29:33 PM
• Our units must be installed in compliance with
the spaces indicated in the installation manual
to ensure either accessibility from both sides
or ability to perform routine maintenance and
repairs. The units’ components must be accessible
and that can be disassembled in conditions of
complete safety either for people or things. For
this reason, where it is not observed as indicated
into the Installation Manual, the cost necessary
to reach and repair the unit (in safety, as required
by current regulations in force) with slings, trucks,
scaffolding or any other means of elevation won’t
be considered in-warranty and will be charged to
end user.
• When installing the outdoor unit at the seaside,
make sure that it is not directly exposed to sea
breeze. If you cannot find an adequate place free
from direct sea breeze, construct a protection
wall or a protective fence.
–– Install the outdoor unit in a place (such as
near buildings etc.) where it can be protected
from sea breeze. Failure to do so may cause a
damage to the outdoor unit.
Sea breeze
Sea breeze
Outdoor unit
Sea
Sea
Outdoor unit
• If you cannot avoid installing the outdoor unit at
the seaside, construct a protection wall around to
block the sea breeze.
• Construct a protection wall with a solid material
such as concrete to block the sea breeze. Make
sure that the height and the width of the wall are
1.5 times larger than the size of the outdoor unit.
Also, secure a space larger than 600 mm between
the protection wall and the outdoor unit for
exhausted air to ventilate.
Sea
Protection wall
Outdoor unit
• Be sure to clean the sea water and the dust on the
heat exchanger of the outdoor unit and apply a
corrosion inhibitor on it. (At least once in a year.)
Power supply line, fuse, or circuit
breaker
• Always make sure that the power supply is
compliant with current safety standards. Always
install the air conditioner in compliance with
current local safety standards.
• Always verify that a suitable grounding
connection is available.
• Verify that the voltage and frequency of the
power supply comply with the specifications and
that the installed power is sufficient to ensure
the operation of any other domestic appliance
connected to the same electric lines.
• Always verify that the cut-off and protection
switches are suitably dimensioned.
• Verify that the air conditioner is connected to the
power supply in accordance with the instructions
provided in the wiring diagram included in the
manual.
• Always verify that electric connections (cable
entry, section of leads, protections…) are
compliant with the electric specifications and
with the instructions provided in the wiring
scheme. Always verify that all connections comply
with the standards applicable to the installation
of air conditioners.
• Be sure not to perform power cable modification,
extension wiring, and multiple wire connection.
–– It may cause electric shock or fire due to poor
connection, poor insulation, or current limit
override.
–– When extension wiring is required due
to power line damage, refer to "Step 2.4
Optional:Extending the power cable" in the
installation manual.
Installation
Sea breeze
• If you have any difficulty finding installation
location as prescribed above, contact your
manufacturer for details.
Outdoor unit
Protection wall
• Install the unit in a place where water can drain
smoothly.
English 29
DB68-06028A-01_A5.indd 29
2/20/2017 5:29:34 PM
Preparation
Step 1.1 Choosing the installation
location
Overview of installation location requirements
CAUTION
• Comply with the length and height limits described
in the figure above.
Minimum clearances for the outdoor unit
Wall
100 mm or more
125 mm
or more
125 mm
or more
Minimum clearance in mm
300
Drain hose hole
You can select the direction of
draining (left or right).
600
Maximum pipe height: 15 m
Maximum pipe length: 30 m
Air flow direction
Make at least one round to
reduce noise and vibration.
Top view
Side view
When installing 1 outdoor unit (6 cases)
(Unit: mm)
1500
300
The actual units may look different from
the images depicted here.
(Unit : m)
8
✴✴19/25✴✴
3
30
15
Outdoor
Unit
Outer wall
Installation
Indoor
Unit
Cut insulation to have
rainwater drained
CAUTION
Make a U-trap (A) on the
pipe (which is connected to
the indoor unit) at outer wall
and cut the bottom part of
the insulation (about 10 mm)
to prevent rainwater from
getting inside through the
insulation.
2000
150
300
1500
Maximum
15
600
300
Maximum
3
1500
Minimum
✴✴10/13✴✴
300
Pipe height
500
Model
Pipe length
30 English
DB68-06028A-01_A5.indd 30
2/20/2017 5:29:36 PM
When installing more than 1 outdoor unit (5cases)
(Unit: mm)
600
3000
3000
200
300
1500
1. Open the indoor unit package.
2. Remove the left and right cushions.
3. Pull out the unit from the package.
Unpacking the outdoor unit
1500
600
Unpacking the indoor unit
1. Remove the package.
2. Remove the top cushion.
3. Pull out the unit from the bottom cushion.
300
1500
600
Step 1.2 Unpacking
Step 1.3 Checking and preparing accessories
and tools
Accessories
300
600
600
600
500
500
Accessories in the indoor unit package
300
Installation plate (1)
✴✴10/13✴✴
Installation plate (1)
✴✴19/25✴✴
Remote control (1)
Remote control holder (1)
Remote control battery (2)
User and Installation
Manual (1)
M4 x 12 tapping screw (2)
Cap screw (2)
300
CAUTION
Installation
• If the outdoor unit is installed with any insufficient
clearance, it may generate sound and affect the
whole product.
• Be sure to install the outdoor unit in a level place
where its vibration does not affect the whole
product.
English 31
DB68-06028A-01_A5.indd 31
2/20/2017 5:29:39 PM
Optional accessories
Accessories in the outdoor unit package
Insulated assembly pipe,
Ø 6.35 mm (1)
Insulated assembly pipe,
Ø 9.52 mm (1)
✴✴10/13✴✴
Rubber leg (4)
Insulated assembly pipe,
Ø 12.70 mm (1)
✴✴19✴✴
Insulated assembly pipe,
Ø 15.88 mm (1)
✴✴25✴✴
Drain Hose, 2 m long (1)
Pipe clamp B (3)
NOTE
• A flare nut is attached to the end of each pipe of an
evaporator or a service port. Use flare nuts when
connecting the pipes.
• Wire assembly cables are optional. If they are not
supplied, use standard cables.
• The drain plug and the rubber legs are included
only when the air conditioner is supplied without
assembly pipes.
• If these accessories are supplied, they are in the
accessory package or outdoor unit package.
Pipe clamp A (3)
Vinyl tape (2)
Tools
General tools
Installation
PE T3 foam tube
insulation (1)
Putty 100 g (1)
Drain plug (1)
M4 x 25 tapped screw (6)
Cement nail (6)
3-wire assembly cable (1)
3-wire power cable (1)
2-wire assembly cable (1)
• Vacuum pump
(Backward flowing prevention)
• Manifold gauge
• Stud finder
• Torque wrench
• Pipe cutter
• Reamer
• Pipe bender
• Spirit level
• Screwdriver
• Spanner
• Drill
• L-wrench
• Measuring tape
Tools for test operation
• Thermometer
• Resistance meter
• Electroscope
32 English
DB68-06028A-01_A5.indd 32
2/20/2017 5:29:44 PM
Step 1.4 Drilling a hole through the wall
Before fixing the installation plate to a wall and
then fixing the indoor unit to the installation plate,
a window frame, or a gypsum board, you must
determine the position of a hole (with 65 mm inner
diameter) through which the pipe bundle (consisting
of power and communication cables, refrigerant
pipes, and drain hose) will pass and then drill that
hole.
1. Determine the position of a 65 mm hole in
consideration of the possible directions of the
pipe bundle and the minimum distances between
the hole and the installation plate.
2. Drill the hole.
CAUTION
• Be sure to drill only one hole.
• Make sure that the hole slants downwards so that
the drain hose slants downwards to drain water
well.
Wall
Drain hose
Indoor unit
<The hole slants downwards>
Left
Right
Rear right or left
Step 1.5 Taping the pipes, cables, and drain
hose
1. Wrap foam insulation on parts without insulation
on the ends of the refrigerant pipes, as shown in
the figure. This wrapping minimises condensation
problem.
Bottom right
<Possible directions of the pipe bundle>
Insulation
CAUTION
• If changing the pipe direction from left to right,
do not drastically bent it but slowly turn it in the
opposite direction as shown. Otherwise, the pipe
may be damaged in the process.
Pipe bundle hole
Refrigerant pipes
2. Wind the refrigerant pipes, power cable,
communication cable and drain hose with vinyl
tape to make a pipe bundle.
Installation plate
Refrigerant pipes
(assembly pipe)
Vinyl tape
(Unit : mm)
Model
A
B
C
D
✴✴10/13✴✴
36
120
81
36
✴✴19/25✴✴
33
110
110
33
Installation
<Minimum distances between the hole and the
installation plate>
Power and communication cables
(assembly cable)
Drain hose
Pipe bundle hole: Ø 65 mm
English 33
DB68-06028A-01_A5.indd 33
2/20/2017 5:29:46 PM
Indoor Unit Installation
Please scan this QR code for detail
video of indoor unit installation.
2
1
Step 2.1 Disassembling the cover panel
1. Remove the cap screws, then the screws.
Cap screw
Screw
Phillips screwdriver
4
Flat-head screwdriver
2. Unlock the side hooks ( , ), then centre hooks
( ).
Then unlock the bottom hooks ( ) to pull out the
cover panel.
A
Step 2.2 Disassembling the installation
plate
A
B
C
B
Installation
Centre hook (A)
Bottom/Side hook (B/C)
34 English
DB68-06028A-01_A5.indd 34
2/20/2017 5:29:55 PM
Step 2.3 Connecting the power and
communication cables (assembly cable)
Control box
Before
connecting
Correct
Upside down
Damaged
Non-circular
Correct
(Front view)
Correct
(Side view)
Upside down
Non-fitted
After
connecting
F1 F2
Fasten the screws for the wire holders.
Model
✴✴10/13✴✴
✴✴19/25✴✴
3G X 2.5 mm², H07RN-F
Outdoor-to-indoor
power cable
3G X 1.0 mm², H07RN-F
Communication cable
2 X 0.75 mm², H05RN-F
20A
25A
• For the terminal block wiring, use a wire with a
ring terminal socket only. Regular wires without
a ring terminal socket may become a hazard due
to overheating of the electrical contact during
installation.
• If you need to extend the pipe, be sure to extend
the cable, too. The maximum length of each of the
cable and pipe used should not exceed 15 metres
(✴✴10/13✴✴) and 30 metres (✴✴19/25✴✴).
• Do not connect two or more different cables to
extend the length. This connection may cause fire.
• Each circular terminal must match the size of its
corresponding screw in the terminal block.
• After connecting the cables, make sure that terminal
numbers on the indoor and outdoor units match.
• Ensure that power and communication cables are
separated, they must not be in the same cable.
WARNING
• Connect the wires firmly so that wires cannot be
pulled out easily. (If they are loose, it could cause
burn-out of the wires.)
Installation
Power cable
(Outdoor unit)
Type GL
NOTE
• Each wire is labelled with the corresponding
terminal number.
• Use shield cable (Category 5; less than 50pF/m) for
noisy environmental site.
• Power supply cords of parts of appliances
for outdoor use shall not be lighter than
polychloroprene sheathed flexible cord. (Code
designation IEC:60227 IEC53/CENELEC: H05VV-F,
IEC: 60245 IEC 66/CENELEC: H07RN-F, IEC: 60245
IEC 57/CENELEC: H05RN-F)
• Power & Communication cable shall not exceed
30m.
CAUTION
<Circular terminal>
1(L)2(N)
• When performing electrical and earthing works,
be sure to comply with the 'technical standards of
electrical installations' and the 'wiring regulations' in
the local regulations.
• Tighten the terminal block screw to 1.2-1.8 N•m
(1.2-1.8 kgf•cm).
English 35
DB68-06028A-01_A5.indd 35
2/20/2017 5:29:57 PM
Step 2.4 Optional: Extending the power
cable
• The compression dimension should be 8.0.
Compression
dimension
1. Prepare the following tools.
Tools
Spec
Crimping pliers
MH-14
Connection sleeve
(mm)
20xØ7.0
(HxOD)
Insulation tape
Width 18
mm
Contraction tube
(mm)
50xØ8.0
(LxOD)
Shape
• After compressing it, pull both sides of the wire to
make sure it is firmly pressed.
Method 1
Method 2
Compress it 4 times.
2. As shown in the figure, peel off the shields from the
rubber and wire of the power cable.
• Peel off 20 mm of cable shields from the preinstalled tube.
CAUTION
Compress it 4 times.
5 mm
5 mm
5. Wrap it with the insulation tape twice or more and
position your contraction tube in the middle of the
insulation tape.
Three or more layers of insulation are required.
Method 1
• For information about the power cable
specifications for indoor and outdoor units, refer
to the installation manual.
• After peeling off cable wires from the preinstalled tube, insert a contraction tube.
Method 2
Insulation tape
Insulation tape
40 mm
35 mm
6. Apply heat to the contraction tube to contract it.
Power cable
Contraction tube
20
20
20
60
120
180
(Unit: mm)
Pre-installed tube for the power cable
20
(Unit: mm)
Installation
3. Insert both sides of core wire of the power cable into the
connection sleeve.
• Method 1: Push the core wire into the sleeve from
both sides.
• Method 2: Twist the wire cores together and push it
into the sleeve.
Method 1
Connection sleeve
7. After tube contraction work is completed, wrap it with
the insulation tape to finish.
Method 2
Insulation tape
CAUTION
• Make sure that the connection parts are not exposed
to outside.
• Be sure to use insulation tape and a contraction tube
made of approved reinforced insulating materials
that have the same level of withstand voltage with
the power cable. (Comply with the local regulations
on extensions.)
Connection sleeve
4. Using a crimping tool, compress the two points and flip
it over and compress another two points in the same
location.
36 English
DB68-06028A-01_A5.indd 36
2/20/2017 5:30:01 PM
WARNING
CAUTION
• In case of extending the
electric wire, please DO
NOT use a round-shaped
pressing socket.
–– Incomplete wire
connections can cause electric shock or a fire.
Step 2.5 Installing and connecting the drain
hose
1. Install the drain hose.
• Make sure that the indoor unit is in upright position
when you pour water to check for leakage. Make sure
that the water does not overflow onto the electrical
part.
• If the diameter of the connection hose is smaller
than the product's drain hose, water leakage may
occur.
• Inadequate installation may cause water leakage.
• If the drain hose is routed inside the room, insulate
the hose so that dripping condensation does not
damage the furniture or floors.
• Do not box in or cover the drain hose connection.
Drain hose connection must be easily accessible and
serviceable.
Step 2.6 Optional: Extending the drain hose
Drain hose
Assembly pipe
Connection hose
Drain hose (A)
Extension drain hose (B)
Wall
Indoor unit
Drain hose
Slant downwards
Water
Slant upwards
Dipped in water
(A)
Drain hose
5 cm
less
Bent
Too small
clearance
(B)
Extension drain hose
Ditch
Too small
clearance
20 mm or more
Foam insulation
Installation
2. Pour water into the drain pan. Check whether the
hose is well drained.
Vinyl tape
English 37
DB68-06028A-01_A5.indd 37
2/20/2017 5:30:03 PM
Step 2.7 Optional: Changing the direction of
the drain hose
Drain pan outlet
Rubber cap
Step 2.8 Installing and connecting the
assembly pipes to the refrigerant pipes
(assembly pipe)
Connect indoor and outdoor units with field-supplied
copper pipes by means of flare connections. Use
insulated seamless refrigeration grade pipe only,
(Cu DHP type according to ISO1337), degreased and
deoxidized, suitable for operating pressures of at least
4200 kPa and for burst pressure of at least 20700 kPa.
Under no circumstances must sanitary type copper pipe
be used.
Pour water in the direction of arrow.
There are 2 refrigerant pipes of different diameters:
• The smaller one is for the liquid refrigerant
• The larger one is for the gas refrigerant
<Front view>
Direction of the drained water
<Side view>
A short liquid refrigerant pipe and a short gas refrigerant
pipe are already fitted to the air conditioner. The
connection procedure for the refrigerant pipes varies
according to the exit position of each pipe when facing
the wall:
Left
Right
Underside
<Front view>
CAUTION
• Make sure that the indoor unit is in upright position
when you pour water to check for leakage. Make sure
that the water does not overflow onto the electrical
part.
Rear right or left
Installation
<Side view>
38 English
DB68-06028A-01_A5.indd 38
2/20/2017 5:30:04 PM
1. Cut out the appropriate knock-out piece (A, B, C)
on the rear of the indoor unit unless you connect
the pipe directly from the rear.
2. Smooth the cut edges.
3. Remove the protection caps of the pipes and
connect the assembly pipe to each pipe. Tighten
the nuts first with your hands, and then with a
torque wrench, applying the following torque:
Outer diameter (mm) Torque (N•m)
Step 2.9 Shortening or extending the
refrigerant pipes (assembly pipe)
Pipe cutter
Torque (kgf•cm)
ø 6.35
14 to 18
140 to 180
ø 9.52
34 to 42
350 to 430
ø 12.70
49 to 61
500 to 620
ø 15.88
68 to 82
690 to 830
Pipe
90°
NOTE
• If you want to shorten or extend the pipes, see
Step 2.9 Shortening or extending the refrigerant
pipes (assembly pipe) on page 39.
4. Cut off the remaining foam insulation.
5. If necessary, bend the pipe to fit along the bottom
of the indoor unit. Then pull it out through the
appropriate hole.
• The pipe should not project from the rear of the
indoor unit.
• The bending radius should be 100 mm or more.
6. Pass the pipe through the hole in the wall.
NOTE
• The pipe will be insulated and fixed permanently
into position after finishing the installation and
the gas leak test. For further details. see Step 4.1
Performing the gas leak tests on page 45.
Oblique
Rough
D
Burr
90°±2°
A
45°±2°
L
R 0.4 to 0.8
Pipe
Flare
D
(Unit: mm)
Outer diameter (D)
Depth (A)
Flare dimension (L)
ø 6.35
1.3
8.7 to 9.1
ø 9.52
1.8
12.8 to 13.2
ø 12.70
2.0
16.2 to 16.6
ø 15.88
2.2
19.3 to 19.7
Flare nut
CAUTION
Indoor outlet pipe
Connecting pipe
Outer diameter (mm)
Torque (N•m)
ø 6.35
14 to 18
Torque (kgf•cm)
140 to 180
ø 9.52
34 to 42
350 to 430
ø 12.70
49 to 61
500 to 620
ø 15.88
68 to 82
690 to 830
Installation
• Tighten the flare nut with a torque wrench according
to specified method. If the flare nut is overtightened, the flare may break and cause refrigerant
gas leakage.
• Do not box in or cover the pipe connection.
All refrigerant pipe connection must be easily
accessible and serviceable.
English 39
DB68-06028A-01_A5.indd 39
2/20/2017 5:30:05 PM
Step 2.10 Fixing the installation plate
CAUTION
• If you need a pipe longer than specified in piping
codes and standards, you must add refrigerant to
the pipe. Otherwise, the indoor unit may freeze.
• While removing burrs, put the pipe face down to
make sure that the burrs do not get in to the pipe.
Liquid service port
<High pressure>
Gas service port
<Low pressure>
You can install the indoor unit on a wall, window frame,
or gypsum board.
WARNING
• Make sure that the wall, window frame, or gypsum
board can withstand the weight of the indoor unit. If
you install the indoor unit in a place where it is not
strong enough to withstand the unit's weight, the
unit could fall and cause injury.
When fixing the indoor unit on a wall
Fix the installation plate to the wall giving attention to
the weight of the indoor unit.
Wall
D
20 mm
A
Plastic anchor
B
C
(Unit : mm)
Correct
Inclined
Cracked
Uneven
thickness
Damaged
surface
<Flare nut>
Installation
NOTE
• Excessive torque may cause gas leakage. When
extending the pipe with welding or brazing,
ensure that nitrogen is used during the welding or
brazing process. The joint must be accessible and
serviceable.
CAUTION
• Tighten the flare nut at the specified torque. If the
flare nut is over-tightened, it may break to cause
leakage of refrigerant gas.
Model
A
B
C
D
✴✴10/13✴✴
36
120
81
36
✴✴19/25✴✴
33
110
110
33
Pipe bundle hole: Ø 65 mm
NOTE
• If you mount the plate to a concrete wall using
plastic anchors, make sure that gaps between the
wall and the plate, created by projected anchor, is
less than 20 mm.
When fixing the indoor unit on a window frame
1. Determine the positions of the wooden uprights
to be attached to the window frame.
2. Attach the wooden uprights to the window frame
giving attention to the weight of the indoor unit.
3. Attach the installation plate to the wooden
upright using tapping screws.
40 English
DB68-06028A-01_A5.indd 40
2/20/2017 5:30:07 PM
When fixing the indoor unit on a gypsum board
1. Use stud finder to find out locations of the studs.
2. Fix the plate hanger on two studs.
CAUTION
• If you fix the indoor unit on a gypsum board, use
only specified anchor bolts on reference positions.
Otherwise, the gypsum surrounding the joints
may crumble over time and cause the screws to be
loosened and stripped. This may lead to physical
injury or equipment damage.
• Search for other spots if there are less than two
studs, or the distance between the studs are
different from the plate hanger.
• Fix the installation plate without inclining to one
side.
A
B
A
B
D
C
C
2
D
1
Step 2.11 Fixing the indoor unit to the
installation plate
B
B
CAUTION
• Make sure that the pipe bundle does not move when
you install the indoor unit onto the installation plate.
C
C
Step 2.12 Assembling the cover panel
1
A
A
Installation
1. Lock the side hooks (D), then centre hooks (B).
Then lock the bottom hooks (C) to engage the
cover panel in place.
2. Fasten the screw (A- ), then assemble the cap
screws (A- ).
2
English 41
DB68-06028A-01_A5.indd 41
2/20/2017 5:30:08 PM
Outdoor Unit Installation
Step 3.1 Fixing the outdoor unit in place
Y
X
NOTE
• Make sure that the wall can support the weights of
the rack and the outdoor unit.
• Install the rack close to the column as much as
possible.
Rubber leg
(Unit : mm)
Model
X
Y
✴✴10KS✴✴
✴✴10/13MS✴✴
507
292
✴✴13KS✴✴
602
310
✴✴19/25✴✴
660
340
1. Place the outdoor unit as directed on the top of
the unit to let the discharged air out properly.
2. Fix the outdoor unit in level to an appropriate
support using anchor bolts.
NOTE
• Secure the rubber legs to help prevent the
generation of noise and vibration.
• If the outdoor unit is exposed to strong winds, install
shield plates around the outdoor unit so that the fan
can operate correctly.
Step 3.2 Connecting the power and
communication cables and the refrigerant
pipes
L
N
F1
Outdoor-to-indoor power cable
(three wires)
Power cable
(three wires)
F2
Communication cable
(two wires)
CAUTION
• Be sure to fix the power cables and communication
cable with a cable clamp.
Optional: Fixing the outdoor unit to a wall with a
rack
Soft rubber designed to cut off vibration from
rack to wall (not supplied with product)
Installation
Soft rubber designed to cut off residual vibration from
outdoor unit to rack (not supplied with product)
42 English
DB68-06028A-01_A5.indd 42
2/20/2017 5:30:09 PM
CAUTION
Control box
Remove the screw for the
control box cover
• When installing, make sure there is no leakage.
When recovering the refrigerant, ground the
compressor first before removing the connection
pipe. If the refrigerant pipe is not properly connected
and the compressor works with the stop valve open,
the pipe inhales the air and it makes the pressure
inside of the refrigerant cycle abnormally high. It
may cause explosion and injury.
1. Leave the system in the standby mode.
WARNING
Remove the gas and liquid
service port caps
For connecting the
refrigerant pipes
• Do not turn on the system! This is necessary for
better vacuum operation (full OPEN position of
Electronic Expansion Valve).
2. Connect the charging hose of the low pressure
side of manifold gauge to a gas service port as
seen in the picture.
Gas service port
<Low pressure>
3
Valve
Liquid service port
<High pressure>
15 minutes
4
Connect the gas and liquid
refrigerant pipes
Vacuum
Pump
(Backward flowing prevention)
Step 3.3 Evacuating the air
Liquid service port <Low pressure>
5
Installation
The outdoor unit is loaded with sufficient R-410A
refrigerant. Do not vent R-410A into atmosphere: it
is a fluorinated greenhouse gas, covered by Kyoto
Protocol, with a Global Warming Potential (GWP) =
2088. You should evacuate the air in the indoor unit
and in the pipe. If air remains in the refrigerant pipes,
it affects the compressor. It may cause reduction
of cooling capacity and malfunction. Use a vacuum
pump.
Liquid service port <High pressure>
English 43
DB68-06028A-01_A5.indd 43
2/20/2017 5:30:11 PM
3. Open the valve of the low pressure side of
manifold gauge anticlockwise.
4. Evacuate the air in the connected pipes using the
vacuum pump for about 15 minutes.
• Make sure that pressure gauge shows -0.1 MPa
(-76 cmHg, 5 torr) after about 10 minutes. This
procedure is very important to avoid a gas leak.
• Close the valve of the low pressure side of
manifold gauge clockwise.
• Turn off the vacuum pump.
• Check for 2 minutes if there is any pressure
change.
• Remove the hose of the low pressure side of
manifold gauge.
5. Set a valve cork of liquid and gas service port to
the open position.
Step 3.4 Adding refrigerant
Siphon
Charge the refrigerant
standing the cylinder upright.
Charge the refrigerant turning
the cylinder upside down.
<Cylinder with siphon>
<Cylinder without siphon>
NOTE
• If R-410A refrigerant is charged with gas, the
composition of the charged refrigerant changes
and the characteristics of the equipment vary.
• During the measuring operation of refrigerant
quantity added use electronic scales. If cylinder
doesn't have siphon, upset it.
If you use a pipe longer than the length specified in
the piping codes and standards, you must add 15 g of
refrigerant R-410A for each extra meter. If you use a
pipe shorter than the length specified in the piping
codes and standards, the evacuating time is normal.
Refer to the Service Manual for further details.
CAUTION
• The remaining air in the Refrigeration cycle,
which contains moisture, may cause malfunction
on the compressor.
• Always contact the service centre or a
professional installation agency for product
installation.
Installation
R-410A is a mixed type of refrigerant. It is necessary
for recharging under conditions of liquid. When
recharging refrigerant from the refrigerant cylinder
to the equipment.
Before recharging, check whether the cylinder has
a siphon or not. There are two ways to recharge the
refrigerant:
44 English
DB68-06028A-01_A5.indd 44
2/20/2017 5:30:12 PM
Installation Inspection
Test parts for the
indoor unit
Step 4.1 Performing the gas leak tests
1. Before inspecting the leakage, use a torque
wrench to close the cap for the stop valve.
(Comply with a tightening torque for each size
of the diameter, and tighten the cap firmly to
prevent any leakage.)
Test parts for the
indoor unit
Tightening torque for body cap
(Refer to the table)
Charging core
Step 4.2 Running the Smart Install mode
Spindle
R-22: Thread of the screw - 7/16-2OUNF
R-410A: Thread of the screw -1/2-2OUNF
Tightening torque for charging port cap (Refer to the table)
Outer diameter
(mm)
Tightening torque
Body cap
(N•m)
ø 6.35
20 to 25
ø 9.52
20 to 25
ø 12.70
25 to 30
ø 15.88
30 to 35
Over ø 19.05
35 to 40
Charging port cap (N•m)
1. Make sure that the air conditioner is in the
standby status.
2. Hold down the
(Power),
(Mode), and
(SET) buttons on the remote control
simultaneously for 4 seconds.
3. Wait until Smart Install mode succeeds or fails. It
takes approximately 7 to 13 minutes.
• While Smart Install mode is proceeding:
Type
Display
LED Display
LED1
LED2
LED3
10 to 12
Indoor
unit
indicator
( 1 N•m = 10 kgf•cm )
2. Insert inert gas into the pipes connected to indoor
and outdoor units.
3. Test leakage on the connection parts of the indoor
and outdoor units with soap lather or liquid.
The LEDs on
the indoor unit
display blink in
sequence, then
all of them blink
simultaneously.
These operations
repeat.
• When Smart Install mode succeeds: Smart
Install mode ends with ringing sound, and the air
conditioner is in standby status.
• When Smart Install mode fails: An error message
is displayed on the indoor unit display, and Smart
Install mode ends.
NOTE
• Smart Install mode can be operated only with the
supplied remote control.
• During the Smart install mode procedure, remote
control cannot be operated.
Installation
Test parts for the
indoor unit
The progress is
displayed as a
number between
0 and 99 on
the indoor unit
display.
English 45
Test parts for the
indoor unit
DB68-06028A-01_A5.indd 45
2/20/2017 5:30:14 PM
When error occurs, take necessary measures by referring to the following table. For more information on necessary
measures for errors, refer to the service manual.
Error indicator
LED Display
Display
LED 1 LED 2
LED 3
/
Error
Measures for the installer to take
Communication
error between
indoor and outdoor
units
• Check the connection wire between
the indoor and outdoor units (whether
the power cable or communication
cable is crossed or not).
Error on indoor
temperature sensor
• Check the connection of the
connector.
Error on indoor heat
exchanger
• Check the connection of the
connector.
Error on indoor fan
motor
• Check the connection of the
connector.
• Remove foreign substance. (Check for
the cause that restrains motor.)
EEPROM/Option
error
• Re-set options.
Refrigerant flow
blocking error
• Check if the stop valve is completely
open.
• Check if there is any blockage in the
refrigerant pipe which connects the
indoor and outdoor units.
• Check for refrigerant leak.
Lack of refrigerant
(for inverter models
only)
• Check if a sufficient amount of
refrigerant is additionally charged
for the pipe longer than specified in
piping codes and standards.
• Check for refrigerant leak between
valve and pipe connection.
/
,
display
and all LEDs
blink.
,
Installation
❈ This LED pattern
appears when an
error occurs on the
outdoor unit.
❈
: Off,
: Blinking,
: On
46 English
DB68-06028A-01_A5.indd 46
2/20/2017 5:30:17 PM
Step 4.3 Performing final check and trial
operation
1. Check the following:
• Strength of the installation site
• Tightness of pipe connection to detect gas
leak
• Electric wiring connection
• Heat-resistant insulation of the pipe
• Drainage
• Grounding conductor connection
• Correct operation (Take the following steps.)
(Power) button on the remote
2. Press the
control to check the following:
• The indicator on the indoor unit lights up.
• The airflow blade opens and the fan gears up
for operation.
3. Press the
(Mode) button to select Cool or Heat
mode. Then take the following sub-steps:
• In Cool mode, use the Temperature button to
set the set temperature to 16 °C.
• In Heat mode, use the Temperature button to
set the set temperature to 30 °C.
• Check whether, approximately 3 to 5 minutes
later, the outdoor unit starts, and a cool or
warm air blows out.
• After 12 minutes of stationary condition, check
the indoor unit air treatment.
4. Press the
(Air swing) button to check whether
the airflow blades work properly.
5. Press the
(Power) button to stop the trial
operation.
4. Turn off the air conditioner and switch mains
supply off.
5. Disconnect tubing. After disconnection, protect
valves and tubing ends from dust.
CAUTION
• Compressor damage may occur if the compressor is
run at a negative suction pressure.
Pumping down for removing the product
(Power) button on the indoor
1. Hold down the
unit for 5 seconds. Beep sounds immediately to
indicate that the product is ready for pump down
procedure.
2. Let the compressor run for more than 5 minutes.
3. Release the valve caps on High and Low pressure
side.
4. Use L-wrench to close the valve on the high
pressure side.
5. After approximately 1 minute, close the valve on
the low pressure side.
6. Stop operation of the air conditioner by pressing
the
(Power) button on the indoor unit or
remote control.
7. Disconnect the pipes.
1
1 minute
Pumping down refrigerant
Liquid service port
<High pressure>
Gas service port
<Low pressure>
Installation
Pump-down is an operation intended to collect
all the system refrigerant in the outdoor unit. This
operation must be carried out before disconnecting the
refrigerant tubing in order to avoid refrigerant loss to the
atmosphere.
1. Shut off the liquid valve with the Allen wrench.
2. Turn on the air conditioner in cooling with fan
operating at high velocity. (Compressor will
immediately start, provided 3 minutes have
elapsed since the last stop.)
3. After 2 minutes of operation, shut the suction
valve with the same wrench.
2
Off
English 47