Dometic HIPRO4000 User Manual

Dometic HIPRO4000 User Manual
INSTRUCTIONS for USE
INSTALLATION INSTRUCTIONS
miniBar
HiPro 3000
HiPro 4000
HiPro 6000
HiPro Vision
ENGLISH
Type H20 / 60
821 2660-01
T.B. 04/2005 MB
TABLE OF CONTENTS
1.0
INTRODUCTION
3
2.0
FOR YOUR SAFETY
3
2.1
2.2
3
3
Warnings and Safety Advice
Coolant
3.0
WARRANTY AND
CUSTOMER SERVICE
3
4.0
INSTALLATION
4
4.1
4.2
4.3
4.4
4.5
4.6
4.7
4
4
4
4
5
6
6
5.0
The Purpose of this Manual
Tools/Materials Required
Unpacking
Cleaning
Installation
Securing
Connecting the Device to the
Electricity Supply
4.8 Changing the Sliding Hinge
4.9 Changing the Doorhang
4.10 Decor Panel
8
9
10
INSTRUCTION FOR USE
11
5.1
5.2
5.3
5.4
5.5
5.6
5.7
5.8
5.9
5.10
5.11
5.12
5.13
5.14
11
11
11
11
12
12
12
13
14
14
15
15
15
15
Initial Operation
Temperature Control
Automatic Defrost Function
Leakage Detection
Postioning the Storage Rack
Interior Light
Door-opening Control Device
Check List
Technical Data
Spare Parts
Environmental Advice
Disposal
Energy Saving Tips
Declaration of Conformity
Model No.
Information
Attention
Environmental
Advice
Warning
Product No.
Serial No.
These operating instructions should be kept in a safe place.
If this device is passed on, please include these operating instructions with it.
2
1.0
INTRODUCTION
You have made an excellent choice by choosing the Dometic miniBar.
We are convinced that you will be satisfied with your new appliance in every way.
Silent in operation because of the Absorption principle, the miniBar fulfils high quality
standards and guarantees an efficient use of resources and energy during its entire
working life, i.e. during manufacturing, use and disposal.
Please study the installation and operating instructions carefully before
attempting to operate the miniBar.
2.0
FOR YOUR SAFETY
Warnings and Safety Advice
2.1
2.2
In the interests of children's safety:
When disposing of the refrigerator, remove all doors and leave the
shelves inside. This prevents children from being accidentally trapped or
suffocated in the refrigerator.
Never open the cooling unit - it is under high pressure.
Never store explosive substances, such as lighter fuel, petrol, ether or
similar products in the miniBar.
The minibar is not suitable for the proper storage of medications.
The miniBar must be installed in such a way that accidental contact with
the cooling unit (which heats up when in use) is impossible.
The appliance has to be connected to a properly earthed socket in line
with the relevant valid country regulations.
Servicing must only be carried out by authorised service personnel.
Coolant
Ammonia is used as a coolant.
This is a natural compound also used in household cleaning agents (1 litre of
Salmiak cleaner contains up to 200g of ammonia - about twice as much as is
used in the refrigerator). Sodium chromate is used for corrosion protection
(1,8% of the coolant).
If a leak occurs (which can be easily detected due to the unpleasant smell):
Switch the device off (pull mains plug, if applicable);
Ventilate room thoroughly.
Inform hotel personnel.
For the safety of hotel guests and personnel, it has been established by
inspectors that the coolant poses no threat to health.
3.0
WARRANTY AND CUSTOMER SERVICE
Warranty arrangements are in accordance with EC Directive 44/1999/CE and the
normal conditions applicable for the country concerned.
For warranty or other servicing, please contact our Dometic service department.
Any damage due to improper use is not covered by the warranty. The warranty
does not cover any modifications to the appliance or the use of non-original
Dometic parts; the warranty does not apply if the installation and operating
instructions are not adhered to and no liability shall be entertained. Parts can be
ordered throughout Europe from our Dometic service department.
When contacting customer service, please always state model, product number,
3
MLC-Code and serial number !
You can find this information on the model label inside the device.
e.g.
4.0
4.1
HiPro 3000
INSTALLATION
The Purpose of this Manual
The manual shows you how to:
install the miniBar correctly.
operate the miniBar correctly.
guarantee the miniBar´s correct maintenance and functioning.
deal with faults by yourself.
4.2
Tools / Materials Required
You will need the following tools for initial operation:
mild detergent
4.3
Unpacking
Check during unpacking that the device is defect-free.
Report transport damage to the transport company within 48 hours.
Check that the voltage noted on the model label corresponds to the
mains voltage.
Depending on the model, the following parts can be found in the miniBar :
2x
4.4
sliding hinge
Reflector
Special
Equipment
IR-transmitter
Cleaning
Before operating the miniBar, we recommend you clean it both inside and
outside.
Use a soft cloth, lukewarm water and a mild detergent.
Following this, wash out the miniBar using clean water and dry thoroughly.
At annual intervals, remove dust from fridge aggregate using a brush or
soft cloth.
ATTENTION
To prevent material damage:
Do not use soap or detergents which are harsh, coarse or which contain
soda.
Keep the door seal free from oil and grease.
The cylinder locks have been lubricated in the factory to be long-lasting.
4
4.5
Installation
200 cm²
20 mm
IMPORTANT:
Please follow the installation details below
carefully. Guarantee is valid for products
installed as described only.
1. The refrigerator must be level both directions.
2. There should be 20mm clearance to the wall.
3. Ventilation must be provided as shown in
alternatives A, B, C or D.
4. The ventilation duct must at least measure
105mm x the width of the refrigerator.
5. Only the entire cooling unit must project into
the duct as shown.
6 Air passing through the duct must not be
preheated by any source of heat.
7. Ventilation grills, if used, must have openings
of at least 200cm² each.
The mains plug/socket must be freely accessible once the
miniBar has been installed.
5
4.6
Securing
When being built into a cupboard or
a recess, the miniBar must be positioned in such a manner that both
hinges/feet of the unit lie flush.
The miniBar is then (see Figures a,
b) screwed, at its hinges, to the
piece of furniture in question.
In the case of units with 8mm feet
and with LED option for the door
opening control, the reflector delivered with the unit must also be
installed in the manner shown in
Figure a.
Drive in the screws and place the caps
on.
Stick on
supplied reflector., ...
4.7
Connecting the Device to the Electricity Supply
The device must be connected to a properly earthed
socket in line with the relevant valid country
regulations.
The mains plug/socket must be freely accessible.
Check prior to initial operation that the voltage
noted on the model label corresponds to the
mains voltage.
If this is not the case, do not connect the
device and contact your dealer!
If the connection cable is damaged it must be replaced by the Customer
Service at Dometic, or by respectively qualified personnel, in order to prevent any hazards.
6
4.7.1
Attention: For GB only !
Plug connection for United Kingdom only
If a 3-pin plug is used, it should be fitted with a 3 amp fuse,
with other plug types, the circuit should contain a 5 amp fuse.
Warning - This appliance must be earthed.
IMPORTANT
The wires in the mains lead of this appliance
are coloured in accordance with the following
code:
GREEN and YELLOW
: EARTH
BLUE
: NEUTRAL
BROWN
: LIVE
As the colours of the wires in the mains lead
may not correspond with the coloured markings
identifying the terminals in your plug, proceed as
follows.
1. Connect the GREEN and YELLOW coloured wire to the plug terminal
marked letter E or earth symbol or coloured green or green and yellow.
2. Connect the BROWN coloured wire to the plug terminal marked letter L
or coloured red.
3. Connect the BLUE coloured wire to the plug terminal marked letter N or
coloured black.
Moulded-On Plug Version
The mains lead is fitted with a non-rewirable moulded-on plug containing
a 3 amp fuse. If the fuse requires replacing at any time, the fuse
cover/carrier should be removed using a small screwdriver to level out. The
old fuse should be replaced by a 3 amp ASTA approved BS1362 fuse and
the fuse cover/carrier must be refitted before the plug is used again.
If the fuse cover-carrier is lost, a replaceement can be obtained from the
Dometic Service Shops.
The fuse cover/carrier must be of the same colour as that of the coloured
insert in the base of the plug. In no circumstances must the plug be used
without a correct fuse cover/carrier fitted.
If the plug supplied on the mains lead is not suitable for the socket in your
home, it should be cut off and disposed of safely, or destroyed, to avoid any
possible shock hazard resulting from the plug being inserted into a 13 amp
socket elswhere in the use. A suitable replacement plug should then be
fitted as given above.
7
4.8
Changing the Sliding Hinge
1.
2.
1.
2.
3.
4.
Distance to cupboard door (A)
1.
mm
A
2.
mm
1. When closed, the cupboard door (A) must not lie against the rest of the
surrounding cupboard area (distance 1-2mm).
2. There must be a distance of 6-8mm between the cupboard door and the
miniBar.
8
4.9
Changing the Doorhang
(optional) LED
door-opening control always opposite
the hanging side
device with feet
LED
If the miniBar is equipped with the LED first carry out steps a. - e. :
a.
Pull out LED, lay the cable
into the cable routing and
insert the LED at the opposite side.
d.
d. + e.
device with feet
e.
b.
c.
Pull the lower hinges forwards, pull out the door with the hinge.
3.
1.
2.
Remove the upper hinge pin and insert on the other side, change the lower pin in the door.
Then push the door in together with the lower hinge.
4.
6.
5.
9
4.10
Decor Panel
4.10.1
Measurements
Thickness
W
0,4 mm
H x W (mm)
h
a
HiPro 3000
492 x 294,5
HiPro 4000
524 x 311,5
HiPro 6000
533 x 376,5
H
Hole for door lock (a)
diameter
O 23,5 mm
distance from the edge (h) 62 mm
4.10.2
Changing the decor panel
A
C
B
-
Detach the lower door hinge and pull the door out (see also "4.9").
Remove the holder for the lock (A) (mounted).
Detach the lower frame section (B) (not screwed) and remove.
Slightly bend the decorative panel (C) and pull it out of the door frame.
Push in a new decorative panel with the upper edge running exactly
parallel to the upper part of the frame.
- Place the frame section (B) on and press firmly (clip in)
- Place the door onto the lower hinge, insert the hinge pin into the top of the
door, push the door with the hinge into the hinge receptacle at the bottom
and allow the hinge to notch. Insert the hinge pin in the door, push in
the door and let the hinge click in.
Remark (devices without doorlock):
- Additional installation of a door lock is possible (available from Dometic)
- In the door the position for the opening is prepared.
- Drill the hole in accordance to the drawing above.
10
5.0
5.1
INSTRUCTION for USE
Initial Operation
The device must be plugged into a properly
earthed socket.
The miniBar starts automatically with a selftest. If the electronics do not detect any
fault, the LED for the interior lighting illuminates for 2 seconds after approximately 10
seconds. If a fault is detected, the illumination changes to a continuous flashing light.
If this occurs, please consult your authorised
Customer Service.
The miniBar achieves its operating
temperature after several hours.
The miniBar
operates silently !
5.2
Temperature Control
The miniBar is fitted with an electronic
temperature control which works fully YELLOW = 3°C
automatically.
A preadjustment of 3° or 5° is possible by
means of an optional remote control.
5.3
BLUE = 5°C
Automatic Defrost Function
The first defrosting phase commences 39 hours after the initial operation
and lasts for two hours.
After this, the device operates for 22 hours at a time, followed by a
defrosting period of 2 hours .
The ice layer must never be removed using force, nor
must the defrosting process ever be accelerated using a
heater.
5.4
Leakage Detection
The electronics carry out a leakage test after every defrosting period
(every 24 hrs) by measuring the temperature at the evaporator by means of
a second sensor.
If the electronics detect a leak, the miniBar is automatically switched off .
The LED for the interior lighting changes after approx. 10 secs. to a continuous flashing. (The LED of the door-opening control flashes synchronously , if available.)
11
5.5
Positioning of the Storage Rack and Shelf
- Pull out the storage rack until it is blocked.
- Press in the lock of both running rails.
- Remove storage rack and running rails and place it at the desired position.
- After clicking in the the storage rack it is secured against pulling out
completely again.
1
2
5.6
Interior Light
Two LEDs (A) light the cooling compartment whilst
the door is opened.
Two sensors (B) control the LEDs and the (optional)
door control as well.
5.7
B
A
Automatic Door Control [ADC] (optional)
The LED (A) placed at the bottom edge of the minibar
indicates whether the miniBar door has been opened.
1. Open the miniBar, check its contents and
- if applicable- stock it up again.
2. Reset the door control sensor by means of an
IR-transmitter (RED-DOT-RESET).
3. Close the miniBar.
A
LED
A
red button =
RED-DOT-RESET
Infrared - transmitter
12
Infrarot - Sensor
5.8
Check List
Failure : No cooling (the aggregate at the back of the device is cold).
Possible Cause
Self Help
a.) The device plug is not
plugged in.
a.) Plug in device plug.
b.) No voltage in socket.
b.) Check main fuse.
Authorised Service
c.) The electronics or the sensor
is faulty.
Does the LED flash ?
c.) Install new
electronics or sensor.
d.) Defective heating element.
d.) Install new heating
element.
e.) The device is in its defrosting
phase.
e.) See operating instruction
5.3
Failure : No cooling (the aggregate is warm).
Possible Cause
Self Help
a.) The device is not level.
Leakage test ?
a.) Level the device using a
spirit level.
b.) The device was only
switched on a short while
ago.
b.) Switch on the device and
let it run for 5-6 hours.
c.) Defective cooling unit.
Authorised Service
c.) Exchange device.
Failure : Poor cooling performance.
Possible Cause
Self Help
a.) The cooling aggregate is not
sufficiently ventilated.
a.) Check that the ventilation
grids are not covered.
Check that device has
been installed properly
(installation instruction 4.5).
b.) The device is exposed to
direct sunlight.
b.) Follow installation
instruction 4.5.
c.) The fridge door does not
close tightly
c.) Check installation in line
4.5 + 4.8 .
d.) The fridge was stocked a
short while ago.
d.) Check fridge after
5-6 hours for proper
cooling function.
Authorised Service
c.) Install new doorseal,
if necessary.
Failure : Frost formation in fridge.
Possible Cause
Self Help
Authorised Service
a.) The fridge door does not
close tightly.
a.) Check installation is in line
with 4.5 + 4.8.
a.) Install new doorseal,
if necessary.
13
5.9
Technical Data
Model
HiPro 3000
Casing
Plastic
Gross Contents ( litres)
28
cooled / uncooled
28 / -
Dimensions (mm)
(H x W xD)
527 x 388 x 418
Electrical Rating (W)
65
Power Consumption
kWh / 24h*
0,6
Net Weight (kg)
12
Assembly
x
freestanding
x
Model
HiPro 4000
Casing
Plastic
Gross Contents ( litres)
37
cooled / uncooled
37 / -
with cooling unit cover + feet
Dimensions (mm)
(H x W xD)
559 x 405 x 452
Electrical Rating (W)
65
601 x 405 x 472
Power Consumption
kWh / 24h*
0,7
Net Weight (kg)
13.5
Assembly
x
freestanding
x
Model
HiPro 6000
Casing
Plastic
Gross Contents ( litres)
51
cooled / uncooled
51 / -
14.5
x
with cooling unit cover + feet
Dimensions (mm)
(H x W xD)
568 x 490 x 474,5
Electrical Rating (W)
80
610 x 490 x 494,6
Power Consumption
kWh / 24h*
0,9
Net Weight (kg)
17
Assembly
x
freestanding
x
18
x
* Power consumption measured at an average ambient temperature of 25°C as an average
annual value and at a cooling compartment temperature of 7°C in line with EN 153.
We reserve the right to make technical changes and modifications without notice!
5.10
Spare Parts
For spare parts please contact your Dometic Service Center
or your dealer.
14
5.11
Environmental Advice
miniBars manufactured by Dometic GmbH are free from CFCs / HCFCs and
fluorinated hydrocarbons. The cooling unit uses ammonia as the coolant (a
natural compound of hydrogen and nitrogen). Cyclopentane, which does not
damage the ozone layer, is used as propellant for the insulation made from
PU-foam.
Disposal
5.12
In order to ensure the re-use of recyclable packaging materials, these must
be disposed of using local collection systems. The device itself must be
handed over to a disposal company or local council which will guarantee
the correct use of recyclable materials and the proper disposal of the rest.
Appliances bearing this symbol must
be deposited at the designated local
reception point for the disposal of electrical and electronic equipment.
It is not permitted that this product be
disposed of by way of the normal
5.13
Dometic refrigerators bear this symbol
on the data plate to be found in the
interior of the unit.
Energy Saving Tips
5.14
household refuse collection system.
If possible, always store pre-cooled goods.
Do not expose the miniBar to direct sunlight and do not place it close
to a source of heat.
An unobstructed air circulation in the fridge aggregate must be ensured.
When removing goods, only open the miniBar briefly.
Switch on the miniBar approx. 12 hours prior to stocking.
Declaration of Conformity
15
Dometic GmbH
In der Steinwiese 16
D-57074 Siegen
www.dometic.de/minibar
www.dometic.com
© Dometic GmbH - 2003 - Subject to change without notice - Printed in Germany