Electrolux UZ 930 S User Manual
Electrolux UZ 930 S vacuum cleaner is a versatile and powerful cleaning solution for both household and commercial use. It features a variety of tools and attachments to tackle different cleaning tasks, including a combination nozzle for hard and soft floors, a universal nozzle for both surfaces, a crevice nozzle for hard-to-reach areas, a small combi-nozzle with a dusting brush and a fold-out nozzle, a brush nozzle for hard floors, and a carpet nozzle with thread pick-up.
PDF
Download
Document
Advertisement
Advertisement
DRY VACUUM CLEANER UZ 930S UZ 930S2 INSTRUCTIONS FOR USE MODE D'EMPLOI BEDIENUNGSANLEITUNG INSTRUCCIONES DE USO ISTRUZIONI PER L’USO INSTRUÇÕES DE MANEJO GEBRUIKSAANWIJZING BRUKSANVISNING BRUGSANVISNING KÄYTTÖOHJE Instrukcii po èkspluatacii Printed in Sweden by AB Åmålstryck 822 2734 000 9905 Edition NA 1 ENGLISH ____________________ 6-7 Electrical connections for UK. only _ 8-9 FRANÇAIS _________________ 10-11 DEUTSCH __________________ 12-13 ESPAÑOL __________________ 14-15 ITALIANO __________________ 16-17 PORTUGUÊS _______________ 18-19 NEDERLANDS ______________ 20-21 SVENSKA __________________ 22-23 NORSK ____________________ 24-25 DANSK ____________________ 26-27 SUOMEKSI _________________ 28-29 Russki\ ______________________ 30-32 2 3 1a 5a 2 1b 5b 5e 5f 6 7 a 4 b c 3 4 5c 5d 5g a 9 b b c 8 e d 5 IMPORTANT SAFEGUARDS This vacuum cleaner can be used for household or commercial use. Accidents due to misuse can only be prevented by those using the machine. When using an electrical appliance, basic precautions should always be followed, including the following: READ AND FOLLOW ALL SAFETY INSTRUCTIONS. WARNING ! To reduce the risk of fire, electric shock, or injury, please read and follow all safety instructions and caution markings before use. This vacuum cleaner is designed to be safe when used to for cleaning functions as specified. Should damage occur to electrical or mechanical parts, the cleaner and / or accessory should be repaired by the manufacturer or competent service station before use in order to avoid further damage to the machine or physical injury to the user. • Do not use outdoors or on wet surfaces. • Disconnect the cleaner before servicing and when not in use. Do not leave the cleaner plugged in unattended. • Do not use with damaged cord or plug. To unplug grasp the plug, not the cord. Do not handle plug or cleaner with wet hands. Turn off all controls before unplugging. • Do not pull or carry by cord, use cord as a handle, close a door on cord, or pull cord around sharp edges or corners. Do not run cleaner over cord. Keep cord away from hea ted surfaces. • Keep hair, loose clothing, fingers and all parts of the body away from openings and moving parts. Do not put any objects into openings or use with opening blocked. Keep openings free of dust, lint, hair, and anything else that could reduce the flow of air. • Do not pick up anything that is burning or smoking, such as cigarettes, matches, or hot ashes. • Use extra care when using on stairs. • Do not use to pick up flammable or combustible liquids such as gasoline, or use in areas where they may be present. • Do not allow it to be used as a toy. Close attention is necessary when used by or near children. • Caution: Do not pick-up hazardous material without Hepafilter mounted. • All contact with the machine, dustbag, filter and all other accessories used when picking-up hazardous materials should be handled according to the regulations valid for the vacuumed material. 6 • Do not use the machine unless filters are fitted. • If the cleaner is not working properly or has been dropped, damaged, left outdoors, or dropped into water, return it to a service center or dealer. • Use only as described in this manual and only with the manufacturer’s recommended attachments. • The use of this machine in conjunction with the pick-up of hazardous materials (such as asbestos) has not been investigated by Underwriters laboratories Inc. • BEFORE YOU PLUG IN YOUR CLEANER, check the rating plate to see if the rated voltage agrees within 10% of the voltage available. • This appliance is provided with double insulation. Use only identical replacement parts. See instructions for servicing of double insulated appliances. SAVE THESE INSTRUCTIONS Servicing double-insulated appliances In a double-insulated appliance, two systems of insulation are provided instead of earthing. No earthing means is provided on a double-insulated appliance, nor should a means for earthing be added to the appliance. Servicing a doubleinsulated appliance requires extreme care and knowledge of the system, and should be done only by qualified service personnel. Replacement parts for a double-insulated appliance must be identical to the parts they replace. A double insulated appliance is marked with the words "DOUBLE INSULATION" or "DOUBLE INSULATED." The symbol (square within a square) may also be used on the product. Noise level according to BS UZ 930 S UZ 930 S2 reduced speed UZ 930 S2 full speed 5415: 58,5 dB(A) 49,5 dB(A) 58,5 dB(A) Noise level with the nozzle against the floor according to IEC 704: UZ 930 S 76 dB(A) UZ 930 S2 reduced speed 71 dB(A) UZ 930 S2 full speed 76 dB(A) This appliance conforms with EC-Directive 89/336/EEC, EEC, 93/31/EEC, 73/23/EEC, 93/68/EEC. INSTRUCTIONS FOR USE 7. Start/Stop 1. To open a)Foot-operated on/off switch. b)On the S2 version a separate switch is provided to change the motor speed . c)Plug-in point for powered carpet nozzle. Power is supplied to the socket when the machine is switched on. a)Pull the retaining clips upward and outward . b)Lift the cover from the container. 2. Dust bag Fit the opening on the dust bag over the air inlet. Press the membrane over the flanged edge on the inlet. Secure with the lock washer. Use only original dust bags. 3. Hose connection Push the hose coupling all the way in and turn clockwise. 4. Wand assembly Standard: Fit the sections together and twist to lock in place. Telescopic: Push down the catch and then adjust the length. Max.950mm,min.630mm. 5. Tools The accessories shown in the pictures may vary from model to model. a-b)Combination nozzle Adjust the nozzle according to the requirements of the floor you are cleaning. Work with the brush on hard floors and without it on soft floors. c)Universal nozzle for both hard floors and carpets. d)Crevice nozzle Use to clean furniture, radiators and others hard-to-reach places. e)Small combi-nozzle: The small combi-nozzle combines a dusting brush for furniture, picture frames, mouldings etc. with a fold-out nozzle for cleaning curtains, furniture and other soft surfaces. The clip on the hose handle holds the nozzle when it is not in use. f)Brush nozzle for hard floors. g)Carpet nozzle with thread pick-up To use the thread pick-up, turn the nozzle. 6. Suction control The suction control in the hose handle lets you regulate the air-flow to prevent the nozzles from fastening to the surfaces you are vacuum cleaning. 8. Warning! Never attempt to vacuum liquid, glass fragments or ashes! Wet surfaces can expose the operator to possible electrical shock. 9. Filter The filters are located inside the lid. To reach them lift out the filter holder(a). The standard filter(b) and fine filter (c) should be inspected at regular intervals,e.g. when you change dust bags, and replace if necessary.Instead of these two filters you can fit a micro filter of HEPA-quality (e), wich traps 99,99% of all particles larger than 0,3 microns. The machine is also fitted with a backupp filter (d) located above rhe motor. This filter should also be inspected and replaced if necessary. IMPORTANT! The UZ 930S/S2 is equipped with a specially designed cable, which if damaged, must be replaced by a cable of the same type. These cables are avaible at authorized service shops and must be installed by trained personnel. The UZ 930S/S2 is equipped with a thermal cut-out to protect the motor and other vital machine parts from overheating. Should the machine cut out, you will have to wait at least 5-10 minutes for it to automatically reset. While you are waiting, switch the machine off and unplug it, then check the hose, dust bag and filters to be sure that nothing is blocking the flow of air through the machine. NB! Remove the plug from the socket before performing service or maintenance. 7 Please read these essential instructions (Only applicable to UK) UZ 930S/S2 are designed, developed and rigorously tested to function efficiently and safely when properly maintained and used in accordance with the following instructions. These instructions have been prepared with safety and efficiency paramount. The MACHINE OPERATOR must be trained by a suitably qualified instructor, and be made aware of the relevant regulations and legislation currently in force at the time of use. CAUTION - This machine MUST NOT be used in explosive or inflammable atmospheres or where such atmospheres are likely to be produced by the presence of volatile liquid or inflammable gas or vapour. CAUTION - In no circumstances should the power supply cord be wrapped around fingers or any part of the operators person. CAUTION - The electrical supply plug must not be subjected to undue stress by pulling on the power supply cord. 8 Your MACHINE must only be connected to an electrical supply of the same voltage and frequency as indicated on the rating plate. Ensure that the plug fitted to the end of the power supply cord is suitable for your supply socket, if not refer to the information contained in 'Electrical Connections', or consult a qualified electrician. The electrical installation from which the supply is drawn must be maintained to current Institute of Electrical Engineers wiring regulations. REGULAR SERVICING and INSPECTION of your machine must be carried out by suitably qualified personnel in accordance with relevant legislation and regulations. In particular, electrical tests for earth continuity, insulation resistance, and condition of the flexible cord should be checked frequently. In the event of any defect the machine MUST be withdrawn from service, completely checked and repaired. Trained Service Engineers will be pleased to carry out on site servicing on a regular or as requested basis, to ensure the continuing safety and efficiency of your machine. ELECTRICAL CONNECTIONS (Only applicable to UK) GROUNDED MACHINES IMPORTANT 240 volt 50 Hz. machines are fitted with a 13 amp. 3 pin moulded plug. the plug is fitted with a 7 amp. detachable fuse. The correct replacement for the fuse is identified by marking or colour coding. Only fuses that are ASTA approved to BS 1362 should be fitted. Never use the plug without the fuse cover fitted. Replacement fuse covers are available at any electrical retail outlet. If the available socket outlet is not suitable for the plug supplied, the plug must be cut off and an appropriate plug fitted. The plug thus cut off MUST BE DESTROYED for safety reasons before being disposed of. Machines built for other voltages and frequencies are not normally supplied with a fitted plug. If it is necessary to fit a plug, the wires in this power supply cord are coloured in accordance with the following code: DOUBLE-INSULATED MACHINES IMPORTANT 240 volt 50 Hz. machines are fitted with a 13 amp. 3 pin moulded plug. the plug is fitted with a 13 amp. detachable fuse. The correct replacement for the fuse is identified by marking or colour coding. Only fuses that are ASTA approved to BS 1362 should be fitted. Never use the plug without the fuse cover fitted. Replacement fuse covers are available at any electrical retail outlet. If the available socket outlet is not suitable for the plug supplied, the plug must be cut off and an appropriate plug fitted. The plug thus cut off MUST BE DESTROYED for safety reasons before being disposed of. Machines built for other voltages and frequencies are not normally supplied with a fitted plug. If it is necessary to fit a plug, the wires in this power supply cord are coloured in accordance with the following code: GREEN & YELLOW-EARTH BLUE-NEUTRAL BROWN-LIVE To connect the new plug: The wire which is coloured green & yellow must be connected to the terminal in the plug which is marked with the letter 'E' or by the safety earth symbol or coloured green or green & yellow. The wire which is coloured blue must be connected to the terminal in the plug which is marked with the letter 'N' or is coloured black or blue. The wire which is coloured brown must be connected to the terminal in the plug which is marked with the letter 'L' or is coloured red or brown. If the plug to be fitted does not conform to the above notation then consult a qualified electrician. BLUE-NEUTRAL BROWN-LIVE To connect the new plug: If using a three-pin plug, do not make any connection to the the terminal in the plug which is marked with the letter ‘E’ or by the safety earth symbol or coloured green or green & yellow. This machine is double-insulated and no earth connection is necessary. The wire which is coloured blue must be connected to the terminal in the plug which is marked with the letter ‘N’ or is coloured black or blue. The wire which is coloured brown must be connected to the terminal in the plug which is marked with the letter ‘L’ or is coloured red or brown. If the plug to be fitted does not conform to the above notation then consult a qualified electrician. 9 ">
Advertisement