BORK SHB9818BL is a vacuum cleaner that features a 440 aW suction power on top of a 1800 W power consumption. It includes a textile dust bag, a HEPA H12 filter, and an overheat protection system. The cleaner is also equipped with an electronic power control on the body, a dust bag full indicator, and a BORK Clinic dust bag that prevent dust from leaking by automatically closing as it is pulled out. The cleaner is easy to assemble, featuring a hose, a telescopic tube, a floor nozzle, and a telescopic crevice nozzle.

advertisement

Assistant Bot

Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.

Manual
BORK SHB9818BL User Manual | Manualzz
BORK - VC SHB 9919 BK & VC SHB 91 1
24.10.2006 11:44:55
VAC U U M C L E AN ER
BORK VC SHB 9919 BK/VC SHB 9818 BL
BORK - VC SHB 9919 BK & VC SHB 92 2
24.10.2006 11:44:55
CONTENT
5
Safety recommendations from BORK company
6
Technical parameters
7
Configuration
8
Special features
11
Operating
15
Care and cleaning
18
Troubleshooting
3
BORK - VC SHB 9919 BK & VC SHB 93 3
24.10.2006 11:44:55
Congratulations
on the purchase of your new vacuum cleaner BORK VC SHB 9919 BK/VC SHB 9818 BL
BORK - VC SHB 9919 BK & VC SHB 94 4
24.10.2006 11:44:56
SAFETY RECOMMENDATIONS FROM BORK COMPANY
BORK company draws much attention to safety matters. We design and manufacture our products striving to provide maximal safety for you.
In addition, we ask you to follow simple safety recommendations when using any electrical appliances.
READ ALL INSTRUCTIONS BEFORE OPERATING AND SAVE THEM FOR FUTURE REFERENCE
When using the vacuum cleaner, basic
precautions should always be followed, including
the following: READ ALL INSTRUCTIONS BEFORE
USING THIS VACUUM CLEANER.
Never vacuum:
• Sharp objects.
Safety precautions
• The cleaner should only be used by adults and
only for normal vacuuming in a domestic
environment.
• Hot or cold cinders, lit cigarette butts, etc.
• The vacuum cleaner features double
insulation and does not need to be earthed.
Never vacuum:
• In wet areas.
• Close to flammable gases, etc.
• Without an BORK Clinic (this may damage the
cleaner). A safety device is fitted which
prevents the cover closing without an BORK
Clinic. Do not attempt to force cover shut.
• Fluids (this can cause serious damage to the
machine).
• Fine dust from plaster, concrete, flour or ash,
for example.
The above can cause serious damage to the
motor – damage which is not covered by the
warranty.
• Disconnect the plug from the mains before
cleaning or maintenance of the vacuum
cleaner.
• Regularly check that the cable is not
damaged. Never use the vacuum cleaner if the
cable is damaged.
All service and repairs must be carried out by an
authorised BORK service centre.
Always keep the vacuum cleaner in a dry place.
SAVE THIS INSTRUCTIONS.
Electrical cable precautions:
• A damaged cable must be replaced by an
authorised BORK service centre. Damage to
the cleaner cable will not be covered by the
warranty.
• Never pull or lift the vacuum cleaner by the
cable.
SAFETY RECOMMENDATIONS FROM BORK COMPANY
BORK - VC SHB 9919 BK & VC SHB 95 5
5
24.10.2006 11:44:56
TECHNICAL PARAMETERS
Voltage:
230 V
Power Supply:
50 Hz
Power Consumption: 1900 Вт (VC SHB 9919 BK)
1800 Вт (VC SHB 9818 BL)
WARRANTY
The benefits conferred by this warranty are in
addition to all implied warranties, other rights
and remedies in respect of the product which
the consumer has under the Trade Practices Act
and Territory Laws.
ATTENTION!
The manufacturer reserves the right to change
the technical characteristics because of
constant improvements to products without
additional notification about such changes.
The product is certified in accordance with the
law “on the protection of consumer rights”
6
TECHNICAL PARAMETERS
BORK - VC SHB 9919 BK & VC SHB 96 6
24.10.2006 11:44:56
CONFIGURATION
Cleaner
Hose
Caddie accessory
holder. Contains a
combined brush and
a telescopic crevice
nozzle.
Carpet/hard floor nozzle
Telescopic crevice
nozzle
Combined brush
Turbo nozzle
BORK Clinic dust bag
Textile dust bag
Telescopic tube
Not presented on photo:
Instruction manual
Warranty card
CONFIGURATION
BORK - VC SHB 9919 BK & VC SHB 97 7
1
1
7
24.10.2006 11:44:57
SPECIAL FEATURES
Electronic power
control on the body
Filter O2 of the standard
HEPA H12
Dust bag full indicator
BORK Clinic dust bag
Overheat protection
of the cleaner
440 aW suction power
8
SPECIAL FEATURES
BORK - VC SHB 9919 BK & VC SHB 98 8
24.10.2006 11:44:57
BORK - VC SHB 9919 BK & VC SHB 99 9
24.10.2006 11:44:57
Operating
10
BORK - VC SHB 9919 BK & VC SHB 910 10
24.10.2006 11:44:57
ASSEMBLING VACUUM CLEANER & OPERATION
1
2
5
BEFORE STARTING
1 Check that the BORK Clinic is in place.
2 Insert the hose until the catch clicks to
engage (press the catch to release the hose).
3 Attach the telescopic tube to the hose handle
and the floor nozzle (to disconnect, press the
lock button and pull apart).
4 The hose can easily be removed from the
handle by pressing the retaining button and
pulling out the hose.
3
6
4
7
5 Pull out the cable and plug it in. Press the
foot pedal to rewind the cable (take hold of
the plug to prevent it striking you).
6 Cleaners are fitted with an automatic cable
winder (Autoreverse). Pull out the cable and
plug it in. Move the control forwards to roll
the cable in and out as required. Move it
backwards to lock the cable in position once
it has been rolled out.
8
7 Press the On/Off button with the foot to start
the vacuum cleaner.
8 Adjust suction power using the suction
control on the vacuum cleaner.
ASSEMBLING VACUUM CLEANER & OPERATION
BORK - VC SHB 9919 BK & VC SHB 911 11
11
24.10.2006 11:44:59
ASSEMBLING VACUUM CLEANER & OPERATION
1
2
5
3
6
GETTING THE BEST RESULTS
Hard floors: Use the carpet/hard floor nozzle
with the left pedal in position (1).
Frames, bookshelves, etc.: Use the
combination nozzle as shown in (4) or feather
duster.
Carpets: Use the carpet/hard floor nozzle with
the left pedal in position (2).
Crevices, corners, etc.: Use the extended
crevice nozzle (5). Extend the crevice nozzle
using a finger to push out the extending
section. When the extending section is in its
outermost position, a retaining button locks it
in position. Press this retaining button and push
the crevice nozzle together before placing it
back in the accessory holder.
Reduce suction power for small carpets.
Upholstered furniture: Use the combination
nozzle as shown in (3).
Curtains, lightweight fabrics, etc.: Use the
combination nozzle as shown in (3). Reduce
suction power if necessary.
12
4
7
NOTE!
Do not use turbo nozzle on skin rugs, rugs
with long fringes or a pile depth exceeding
15 mm. To avoid damaging the carpet, do not
keep the nozzle stationary whilst the brush is
rotating.
Do not pass the nozzle across electric cables,
and be sure to switch off the vacuum cleaner
immediately after use.
Using the turbo nozzle: Attach the nozzle to
the tube (6). Adjust the suction power by
opening or closing the air vent (7).
ASSEMBLING VACUUM CLEANER & OPERATION
BORK - VC SHB 9919 BK & VC SHB 912 12
24.10.2006 11:44:59
ASSEMBLING VACUUM CLEANER & OPERATION
1
2
3
THE CLEANER SAVES YOUR BACK WHILST
CLEANING YOUR HOME
1. To save your back, the cleaner features a
flexible handle that makes it easier to lift and
carry the machine.
2 Additionally, the convenient parking position
helps when you take a break during vacuuming.
3 Parking position for storage.
ASSEMBLING VACUUM CLEANER & OPERATION
BORK - VC SHB 9919 BK & VC SHB 913 13
13
24.10.2006 11:44:59
Care and cleaning
14
BORK - VC SHB 9919 BK & VC SHB 914 14
24.10.2006 11:44:59
CARE AND CLEANING
1a (VC SHB 9818 BL)
1b (VC SHB 9919 BK)
2
3
4
5
6b
6a
REPLACING THE DUST BAG BORK CLINIC
1. Replace the BORK Clinic as soon as the
indicator window becomes fully red (1a) or
when the window lights up (1b).
2 Remove the hose and open the lid.
3 Pull the cardboard holder to remove the BORK
Clinic. This automatically closes the dust bag
and stops dust from leaking out.
4 Insert a new BORK Clinic by pushing the
cardboard holder straight down in its tracks.
Close the lid.
7
8
NOTE!
Replace the BORK Clinic even if it is not full
(it may be blocked).
Also replace after using carpet-cleaning
powder. Use only original dust bags – BORK
Clinic.
Replacing the motor filter
(Replace the filter for every 5th replacement of
the BORK Clinic)
9
6. Insert a new filter in the groove (6a). To make
replacement easier, open the container by
pressing on it as shown in (6b).
7 Replace the filter and close the lid.
Replacing HEPA-filter
(When the indicator lamp comes on or for every
5th replacement of the dust bag)
8. Open and remove the lid, then remove the
filter.
9 Replace the filter and lid as shown.
5. Remove the old filter.
CARE AND CLEANING
BORK - VC SHB 9919 BK & VC SHB 915 15
15
24.10.2006 11:45:01
CARE AND CLEANING
1
CLEANING THE HOSE AND NOZZLE
The vacuum cleaner stops automatically if the
nozzle, tube or hose becomes blocked, if the
filter and dust bag are blocked or if the overheat
indicator starts flashing (1). Disconnect from
the mains and allow the vacuum cleaner to cool
for 20-30 minutes.
Clear what is causing the stoppage and/or
replace dirty filters or the full BORK Clinic. Then
restart the vacuum cleaner.
16
2
3
Tubes and hoses
2. Use a cleaning strip or similar to clear the
tubes and hose.
3 It is sometimes possible to clear the hose by
“massaging” it. However, be careful in case
the obstruction has been caused by glass or
needles caught inside the hose.
NOTE!
The warranty does not cover any damage to
hoses caused by cleaning them.
4
5
Cleaning the floor nozzle
4. To avoid deterioration of suction power,
frequently clean the carpet/hard floor nozzle.
The easiest way to clean it is by using the
hose handle.
5 Press each wheel-hub and draw away the
wheels.
6 Remove dust-balls, hair or other objects that
may be entangled. Use the crevice nozzle to
clean the wheel axles.
Replace the wheels by pressing them into
position.
CARE AND CLEANING
BORK - VC SHB 9919 BK & VC SHB 916 16
24.10.2006 11:45:02
CARE AND CLEANING
6
7 Larger objects can be removed by taking off
the connecting tube (press in the small
catches and remove the tube).
8 Remove the object and replace the
connecting tube.
7
8
9
Cleaning the turbo nozzle
9. Remove the nozzle from the vacuum cleaner
tube and remove entangled threads etc. by
snipping them away with scissors. Use the
hose handle to vacuum the nozzle.
CARE AND CLEANING
BORK - VC SHB 9919 BK & VC SHB 917 17
17
24.10.2006 11:45:02
TROUBLESHOOTING
TROUBLESHOOTING AND CONSUMER
INFORMATION
The vacuum cleaner does not start
1 Check that the cable is connected to the
mains.
2 Check that the plug and cable are not
damaged.
3 Check for a blown fuse.
CONSUMER INFORMATION
BORK decline all responsibility for all damages
arising from any improper use of the appliance
or in cases of tampering with the appliance.
This product is designed with the environment
in mind. All plastic parts are marked for
recycling purposes.
The vacuum cleaner stops
1. Check whether the dust bag BORK Clinic is
full. If so, replace it with a new one.
2 Check whether the nozzle, tube or hose are
blocked.
3 Check whether the filters is blocked.
Water has entered the vacuum cleaner
It will be necessary to replace the motor at an
authorised service centre. Damage to the motor
caused by the penetration of water is not
covered by the warranty.
18
TROUBLESHOOTING