BORK SHB9818BL User Manual
BORK SHB9818BL is a vacuum cleaner that features a 440 aW suction power on top of a 1800 W power consumption. It includes a textile dust bag, a HEPA H12 filter, and an overheat protection system. The cleaner is also equipped with an electronic power control on the body, a dust bag full indicator, and a BORK Clinic dust bag that prevent dust from leaking by automatically closing as it is pulled out. The cleaner is easy to assemble, featuring a hose, a telescopic tube, a floor nozzle, and a telescopic crevice nozzle.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
BORK - VC SHB 9919 BK & VC SHB 91 1 24.10.2006 11:44:55 VAC U U M C L E AN ER BORK VC SHB 9919 BK/VC SHB 9818 BL BORK - VC SHB 9919 BK & VC SHB 92 2 24.10.2006 11:44:55 CONTENT 5 Safety recommendations from BORK company 6 Technical parameters 7 Configuration 8 Special features 11 Operating 15 Care and cleaning 18 Troubleshooting 3 BORK - VC SHB 9919 BK & VC SHB 93 3 24.10.2006 11:44:55 Congratulations on the purchase of your new vacuum cleaner BORK VC SHB 9919 BK/VC SHB 9818 BL BORK - VC SHB 9919 BK & VC SHB 94 4 24.10.2006 11:44:56 SAFETY RECOMMENDATIONS FROM BORK COMPANY BORK company draws much attention to safety matters. We design and manufacture our products striving to provide maximal safety for you. In addition, we ask you to follow simple safety recommendations when using any electrical appliances. READ ALL INSTRUCTIONS BEFORE OPERATING AND SAVE THEM FOR FUTURE REFERENCE When using the vacuum cleaner, basic precautions should always be followed, including the following: READ ALL INSTRUCTIONS BEFORE USING THIS VACUUM CLEANER. Never vacuum: • Sharp objects. Safety precautions • The cleaner should only be used by adults and only for normal vacuuming in a domestic environment. • Hot or cold cinders, lit cigarette butts, etc. • The vacuum cleaner features double insulation and does not need to be earthed. Never vacuum: • In wet areas. • Close to flammable gases, etc. • Without an BORK Clinic (this may damage the cleaner). A safety device is fitted which prevents the cover closing without an BORK Clinic. Do not attempt to force cover shut. • Fluids (this can cause serious damage to the machine). • Fine dust from plaster, concrete, flour or ash, for example. The above can cause serious damage to the motor – damage which is not covered by the warranty. • Disconnect the plug from the mains before cleaning or maintenance of the vacuum cleaner. • Regularly check that the cable is not damaged. Never use the vacuum cleaner if the cable is damaged. All service and repairs must be carried out by an authorised BORK service centre. Always keep the vacuum cleaner in a dry place. SAVE THIS INSTRUCTIONS. Electrical cable precautions: • A damaged cable must be replaced by an authorised BORK service centre. Damage to the cleaner cable will not be covered by the warranty. • Never pull or lift the vacuum cleaner by the cable. SAFETY RECOMMENDATIONS FROM BORK COMPANY BORK - VC SHB 9919 BK & VC SHB 95 5 5 24.10.2006 11:44:56 TECHNICAL PARAMETERS Voltage: 230 V Power Supply: 50 Hz Power Consumption: 1900 Вт (VC SHB 9919 BK) 1800 Вт (VC SHB 9818 BL) WARRANTY The benefits conferred by this warranty are in addition to all implied warranties, other rights and remedies in respect of the product which the consumer has under the Trade Practices Act and Territory Laws. ATTENTION! The manufacturer reserves the right to change the technical characteristics because of constant improvements to products without additional notification about such changes. The product is certified in accordance with the law “on the protection of consumer rights” 6 TECHNICAL PARAMETERS BORK - VC SHB 9919 BK & VC SHB 96 6 24.10.2006 11:44:56 CONFIGURATION Cleaner Hose Caddie accessory holder. Contains a combined brush and a telescopic crevice nozzle. Carpet/hard floor nozzle Telescopic crevice nozzle Combined brush Turbo nozzle BORK Clinic dust bag Textile dust bag Telescopic tube Not presented on photo: Instruction manual Warranty card CONFIGURATION BORK - VC SHB 9919 BK & VC SHB 97 7 1 1 7 24.10.2006 11:44:57 SPECIAL FEATURES Electronic power control on the body Filter O2 of the standard HEPA H12 Dust bag full indicator BORK Clinic dust bag Overheat protection of the cleaner 440 aW suction power 8 SPECIAL FEATURES BORK - VC SHB 9919 BK & VC SHB 98 8 24.10.2006 11:44:57 BORK - VC SHB 9919 BK & VC SHB 99 9 24.10.2006 11:44:57 Operating 10 BORK - VC SHB 9919 BK & VC SHB 910 10 24.10.2006 11:44:57 ASSEMBLING VACUUM CLEANER & OPERATION 1 2 5 BEFORE STARTING 1 Check that the BORK Clinic is in place. 2 Insert the hose until the catch clicks to engage (press the catch to release the hose). 3 Attach the telescopic tube to the hose handle and the floor nozzle (to disconnect, press the lock button and pull apart). 4 The hose can easily be removed from the handle by pressing the retaining button and pulling out the hose. 3 6 4 7 5 Pull out the cable and plug it in. Press the foot pedal to rewind the cable (take hold of the plug to prevent it striking you). 6 Cleaners are fitted with an automatic cable winder (Autoreverse). Pull out the cable and plug it in. Move the control forwards to roll the cable in and out as required. Move it backwards to lock the cable in position once it has been rolled out. 8 7 Press the On/Off button with the foot to start the vacuum cleaner. 8 Adjust suction power using the suction control on the vacuum cleaner. ASSEMBLING VACUUM CLEANER & OPERATION BORK - VC SHB 9919 BK & VC SHB 911 11 11 24.10.2006 11:44:59 ASSEMBLING VACUUM CLEANER & OPERATION 1 2 5 3 6 GETTING THE BEST RESULTS Hard floors: Use the carpet/hard floor nozzle with the left pedal in position (1). Frames, bookshelves, etc.: Use the combination nozzle as shown in (4) or feather duster. Carpets: Use the carpet/hard floor nozzle with the left pedal in position (2). Crevices, corners, etc.: Use the extended crevice nozzle (5). Extend the crevice nozzle using a finger to push out the extending section. When the extending section is in its outermost position, a retaining button locks it in position. Press this retaining button and push the crevice nozzle together before placing it back in the accessory holder. Reduce suction power for small carpets. Upholstered furniture: Use the combination nozzle as shown in (3). Curtains, lightweight fabrics, etc.: Use the combination nozzle as shown in (3). Reduce suction power if necessary. 12 4 7 NOTE! Do not use turbo nozzle on skin rugs, rugs with long fringes or a pile depth exceeding 15 mm. To avoid damaging the carpet, do not keep the nozzle stationary whilst the brush is rotating. Do not pass the nozzle across electric cables, and be sure to switch off the vacuum cleaner immediately after use. Using the turbo nozzle: Attach the nozzle to the tube (6). Adjust the suction power by opening or closing the air vent (7). ASSEMBLING VACUUM CLEANER & OPERATION BORK - VC SHB 9919 BK & VC SHB 912 12 24.10.2006 11:44:59 ASSEMBLING VACUUM CLEANER & OPERATION 1 2 3 THE CLEANER SAVES YOUR BACK WHILST CLEANING YOUR HOME 1. To save your back, the cleaner features a flexible handle that makes it easier to lift and carry the machine. 2 Additionally, the convenient parking position helps when you take a break during vacuuming. 3 Parking position for storage. ASSEMBLING VACUUM CLEANER & OPERATION BORK - VC SHB 9919 BK & VC SHB 913 13 13 24.10.2006 11:44:59 Care and cleaning 14 BORK - VC SHB 9919 BK & VC SHB 914 14 24.10.2006 11:44:59 CARE AND CLEANING 1a (VC SHB 9818 BL) 1b (VC SHB 9919 BK) 2 3 4 5 6b 6a REPLACING THE DUST BAG BORK CLINIC 1. Replace the BORK Clinic as soon as the indicator window becomes fully red (1a) or when the window lights up (1b). 2 Remove the hose and open the lid. 3 Pull the cardboard holder to remove the BORK Clinic. This automatically closes the dust bag and stops dust from leaking out. 4 Insert a new BORK Clinic by pushing the cardboard holder straight down in its tracks. Close the lid. 7 8 NOTE! Replace the BORK Clinic even if it is not full (it may be blocked). Also replace after using carpet-cleaning powder. Use only original dust bags – BORK Clinic. Replacing the motor filter (Replace the filter for every 5th replacement of the BORK Clinic) 9 6. Insert a new filter in the groove (6a). To make replacement easier, open the container by pressing on it as shown in (6b). 7 Replace the filter and close the lid. Replacing HEPA-filter (When the indicator lamp comes on or for every 5th replacement of the dust bag) 8. Open and remove the lid, then remove the filter. 9 Replace the filter and lid as shown. 5. Remove the old filter. CARE AND CLEANING BORK - VC SHB 9919 BK & VC SHB 915 15 15 24.10.2006 11:45:01 CARE AND CLEANING 1 CLEANING THE HOSE AND NOZZLE The vacuum cleaner stops automatically if the nozzle, tube or hose becomes blocked, if the filter and dust bag are blocked or if the overheat indicator starts flashing (1). Disconnect from the mains and allow the vacuum cleaner to cool for 20-30 minutes. Clear what is causing the stoppage and/or replace dirty filters or the full BORK Clinic. Then restart the vacuum cleaner. 16 2 3 Tubes and hoses 2. Use a cleaning strip or similar to clear the tubes and hose. 3 It is sometimes possible to clear the hose by “massaging” it. However, be careful in case the obstruction has been caused by glass or needles caught inside the hose. NOTE! The warranty does not cover any damage to hoses caused by cleaning them. 4 5 Cleaning the floor nozzle 4. To avoid deterioration of suction power, frequently clean the carpet/hard floor nozzle. The easiest way to clean it is by using the hose handle. 5 Press each wheel-hub and draw away the wheels. 6 Remove dust-balls, hair or other objects that may be entangled. Use the crevice nozzle to clean the wheel axles. Replace the wheels by pressing them into position. CARE AND CLEANING BORK - VC SHB 9919 BK & VC SHB 916 16 24.10.2006 11:45:02 CARE AND CLEANING 6 7 Larger objects can be removed by taking off the connecting tube (press in the small catches and remove the tube). 8 Remove the object and replace the connecting tube. 7 8 9 Cleaning the turbo nozzle 9. Remove the nozzle from the vacuum cleaner tube and remove entangled threads etc. by snipping them away with scissors. Use the hose handle to vacuum the nozzle. CARE AND CLEANING BORK - VC SHB 9919 BK & VC SHB 917 17 17 24.10.2006 11:45:02 TROUBLESHOOTING TROUBLESHOOTING AND CONSUMER INFORMATION The vacuum cleaner does not start 1 Check that the cable is connected to the mains. 2 Check that the plug and cable are not damaged. 3 Check for a blown fuse. CONSUMER INFORMATION BORK decline all responsibility for all damages arising from any improper use of the appliance or in cases of tampering with the appliance. This product is designed with the environment in mind. All plastic parts are marked for recycling purposes. The vacuum cleaner stops 1. Check whether the dust bag BORK Clinic is full. If so, replace it with a new one. 2 Check whether the nozzle, tube or hose are blocked. 3 Check whether the filters is blocked. Water has entered the vacuum cleaner It will be necessary to replace the motor at an authorised service centre. Damage to the motor caused by the penetration of water is not covered by the warranty. 18 TROUBLESHOOTING BORK - VC SHB 9919 BK & VC SHB 918 18 24.10.2006 11:45:02 BORK - VC SHB 9919 BK & VC SHB 919 19 24.10.2006 11:45:02 8228395-06 BORK - VC SHB 9919 BK & VC SHB 920 20 24.10.2006 11:45:02
advertisement