Supplied accessories for installation
For the Installation of door station
and main monitor station
VL-V554/
VL-V554U
Installation Guide
VL-MWD501
Model No.
VL-SWD501
VL-SWD501U
• VL-V554 is a surface mount type, VL-V554U is a flush
mount type.
• In this manual, the suffix of each model number (e.g.,
the "FX" in "VL-SWD501FX") is omitted.
Flush
mounting
box × 1
Mounting
base × 1
Door station
(VL-V554 only)
Main monitor station
Door station is described as "doorphone"
and Main monitor station is described as
"main monitor" in this guide.
Note to the installer
■ Before attempting to connect or operate this product, please read the label on the rear of
the main monitor.
■ Please read this guide carefully, and install the product safely and correctly by following
the instructions. Carefully read the information found in the section titled "For your safety"
in particular.
■ Only use attachments/accessories specified by the manufacturer.
■ The installation shall be carried out in accordance with all applicable installation rules.
■ Panasonic assumes no responsibility for injuries or property damage resulting from failures
arising out of improper installation or operation inconsistent with this guide. Additionally,
any resulting malfunction will not be covered under the warranty.
■ After installation, make sure to leave this guide with the customer.
For your safety
To prevent severe injury and loss of life/property, read this section carefully before using the
product to ensure proper and safe operation of your product.
WARNING
Preventing fire, electric shock and short circuits
●●Leave installation work to the dealer.
Installation work requires technique and experiences. Failure to observe this may
cause fire, electric shock, injury, or damage to the product. Consult the dealer.
●●Electrical connection work should be performed by certified personnel only. Certification
is required for performing electrical connection work. Consult your dealer.
●●Use only the specified power supply unit.
●●Do not attempt to disassemble or modify this product. Contact an authorised service
centre for repairs.
●●Never install wiring during a lightning storm.
●●Do not connect non-specified devices.
●●Do not connect a power cable to a terminal that is not specified in this guide.
●●When opening holes in walls for installation or wiring, or when securing the power
cable, make sure you do not damage existing wiring and ductwork.
●●Do not make any wiring connections when the power supply is turned on.
●●Do not use the supplied power supply unit for outdoor installations (it is for indoor use only).
●●Do not install the main monitor and power supply unit in the following places:
-- Places where the main monitor and power supply unit may be splashed with water or
chemicals.
-- Places where there is a high concentration of dust, or high humidity.
●●Do not perform any actions (such as fabricating, twisting, stretching, bundling, forcibly
bending, damaging, altering, exposing to heat sources, or placing heavy objects on the
power cable) that may damage the power cable. Using the product with a damaged
power cable may cause electric shock, short circuits, or fire. Contact an authorised
service centre for repairs.
●●When existing chime wires are used, it is possible that they contain AC voltage.
Contact an authorised service centre.
Preventing accidents and injuries
●●Do not install or use the product in health care facilities if any regulations posted in
the area instruct you not to do so. Hospitals or health care facilities may be using
equipment that could be sensitive to external RF (radio frequency) energy.
●●Do not install or use this product near automatically controlled devices such as
automatic doors and fire alarms. Radio waves emitted from this product may cause
such devices to malfunction, resulting in an accident.
CAUTION
Preventing electric shock
●●If the wiring is underground, do not make any connections underground.
●●If the wiring is underground, use a protection tube.
●●If the wiring is outdoors, use a protection tube or a surge protector.
Preventing injury
●●Install the product securely adhering to the instructions in this guide to prevent it from
falling off the wall. Avoid installing onto low-strength walls, such as gypsum board, ALC
(autoclaved lightweight concrete), concrete block, or veneer (less than 18 mm thick) walls.
1-62, 4-chome, Minoshima, Hakata-ku, Fukuoka 812-8531, Japan
PNQW4915ZA C1015MM0
(VL-V554U only)
Screw × 4 (Used when
installing the doorphone)
(VL-V554 : 4 mm x 12 mm)
(VL-V554U : 4 mm x 25 mm)
DOORPHONE 1
MAIN MONITOR
A
Name plate × 2
(incl. 1 spare)
Hex wrench × 1

Mounting
bracket × 1
ブ
プ
NP
NP
Cable binder × 1
NP
■ Power supply unit and related items

D
DOORPHONE 2
C
Power supply
unit × 1
Cable binder × 2
■ For the main monitor
●●Install the main monitor away from electronic appliances such as TVs, radios, personal
computers, air conditioners, boiler control panels with intercom, home security equipment,
wireless devices, or digital cordless phones.
●●Do not install the main monitor in places where it will be affected by extremely high-frequency
radio waves (near broadcasting antennas etc.). This may cause the display to flicker or an
interrupting noise to occur.
●●Leave at least 20 cm of space above, below, and to the left and right sides of the main
monitor. Do not install on a wall that is deeply recessed.
●●Do not install the main monitor inside a wall.
●●Be sure to install the main monitor more than 5 m away from the doorphone.
●●The product operates in the frequency range of 1.88 GHz to 1.90 GHz, and the RF
transmission power is 250 mW (max.). Refer to the "For best performance" section in the
Operating Instructions.
●●In areas surrounded by a high electrical field, disturbances may occur in the main monitor’s
image or sound.
Power
supply
12 V AC/DC
Electric lock
(Electric door
lock)*2
12 V AC/DC
NP
220-240 V AC
E
Electric lock
(Electric vehicle
gate lock)*1
D
B
NP
Connection device for option output (A contact)
NP
Power
supply
Power
supply
12 V AC/DC
Electric lock
(Electric door
lock)*2
12 V AC/DC
NP: Non-polarised
24 V DC
*1 Make sure to only connect electric vehicle gate locks to the S3/S4 terminals of the
doorphones.
*2 Make sure to only connect electric door locks to the S1/S2 terminals of the doorphones.
POWER SUPPLY UNIT
Precautions for installation
■ For the doorphone
●●If a strong light is shining on the doorphone, the visitor’s face may not be distinguishable. Do
not place the doorphone in the following locations:
-- Where most of the background is the sky.
-- Where the background is a white wall, and direct sunlight will reflect off it.
-- Where direct sunlight will shine on the doorphone.
●●Do not place the doorphone in locations where echoing occurs, as this will cause the
doorphone to beep frequently.
●●Dust protection/water protection is IP54.
Only when installation work specified in this guide is properly performed and appropriate water
protection treatment is performed.
●●Make sure the rear of the doorphone is not subject to water.
●●Depending on the installation location, condensation may form on the doorphone’s lens cover.
This may cause images to become obscured. Condensation will dissipate as the temperature
rises.
Power
supply
NP
Important:
●●You will need the following additional items to install and configure the doorphone
and the main monitor.
[Locally procured]
4 mm
-- Screws (for mounting base: × 2, for mounting bracket: × 2):
Prepare the screws (
the drawing on the right) according to
the material, structure, strength and other factors of the mounting
area and the total weight of objects to be mounted.
-- Power cables (AC/DC cables), wires (for doorphone and other connections):
Prepare cables and wires of the appropriate specification. (
"Wire type and length")
Note:
●●The illustrations in the supplied manual(s) may vary slightly from the actual product.
To avoid malfunction or communication disturbances, do not install the doorphone or the main
monitor in the following locations:
-- Places where vibration or any other kind of impact occurs.
-- Places where echoing is frequent.
-- Places near a high concentration of dust, hydrogen sulphide, ammonia, sulphur, or noxious
fumes.
Electric lock
(Electric vehicle
gate lock)*1
NP
■ For the main monitor
(Part No. VL-PS240)
© Panasonic System Networks Co., Ltd. 2015
Set up correctly according to the following wiring schematic diagram and "Wire type and length".
●●For information, such as order numbers, about optional devices that can be connected to, refer to the "Additional/replacement accessories" section in the Operating Instructions.
■ For the doorphone
Wireless Video Intercom System
Wiring schematic diagram
Wire type and length
Wire type*1
Wiring run
Diameter
Main monitor –
Doorphone
Main monitor –
Power supply unit
Power supply unit –
AC power source
Doorphone –
Electric lock
*2
A
B
φ 0.65 mm
22 AWG
100 m
φ 1.0 mm
18 AWG
130 m
φ 0.5 mm
CAT 5
50 m
φ 0.65 mm
22 AWG
10 m
φ 1.0 mm
18 AWG
20 m
C
φ 1.2 mm - φ 2.0 mm
(17 AWG - 12 AWG)
No requirement
D
φ 0.5 mm - φ 1.2 mm
(24 AWG - 17 AWG)
According to specification of connected
device.
E
φ 0.5 mm - φ 1.2 mm
(24 AWG - 17 AWG)
According to specification of connected
device.
Main monitor –
Connection device for option
output (A contact)*2
Length (Max.)
*1Type: Single-pair cable with outer sheath (jacket)
Conductor: Copper solid
●●A certified power supply wiring has to be used with this equipment. The relevant national
installation and/or equipment regulations shall be considered. A certified power supply wiring
not lighter than ordinary polyvinyl chloride flexible wiring according to IEC 60227 shall be used.
*2When using an electric lock or a connection device for option output (A contact), select a device
that meets the following guidelines:
●●Electric lock connection terminal (S1/S2, S3/S4):
-- N/O dry closure contact
-- 12 V AC/DC, less than 1 A
●●Connection device for option output (A contact) terminal (OUT1/OUT2):
-- 24 V AC/DC, less than 0.3 A (minimum contact: 5 V DC 1 mA)
Important:
■ Installation height and area visible by the camera lens
You can use the [Wide/Zoom settings] setting on the main monitor to select the area that
is visible when a visitor calls; available settings are [Wide], [Zoom], and [All] (entire image
display). (Default setting: [Wide])
●●The following values are for when the doorphone is installed in the standard position (the centre
of the doorphone’s height is approximately 1,450 mm) and at a distance of approximately
500 mm from the camera lens.
Image displayed on
main monitor:
(Units: mm)
Image range
Approx. 1,100
1
VL-V554U
View when looking
from above
Approx. 500
Install the flush mounting box in the
wall.
Mounting base
(accessory)
100 mm
Knockout hole*1
When set to zoom
Image displayed on
main monitor:
Displays a portion of the wide image at 2 times the size.
●●Because a digital zoom is used, the image quality of zoom
display is lower than that of wide display or entire image display.
2
●●You can use the main monitor’s [Zoom position settings] setting to select the desired area
visible when zooming. Refer to the following and configure the main monitor.
Up and down
(Units: mm)
Left
Image range
3
Image range:
Approx. 900
Approx. 500
Approx. 85°
3
Connect the AC/DC cable to the AC IN
terminal/DC OUT terminal on the top and
bottom of the power supply unit, and then
secure the wires by tightening the screws.
Approx. 1,500
Approx. 45°
Approx. 1,650
Approx. 400
*1 Make sure that there are no bare wires
exposed outside the product.
Approx. 500
Approx. 500
Approx. 1,250
Attach the doorphone to the mounting
base.
4
Attach the doorphone to the flush mounting
box.
Approx. 45°
Approx. 1,400
4
Approx. 170°
Approx. 850
Approx. 85°
Screws (accessory) × 4
Screws (accessory) × 4
5
Entire image display
Use the cable binders (accessory) to
secure the AC/DC cables (double-coated
area) to the power supply unit.
Cable covers (A)
ARemove screw A and then remove the
terminal cover.
Approx. 115°
Attach the name plate to the doorphone and use screw A to secure the front panel.
1
2
3
Screw B
How to make wiring connections:
While pressing on the button with a pointed object such as a screwdriver, insert
the wire into the terminal connector. (To
disconnect a wire, while pressing on the
button, pull out the wire.)
Bare wire at tip Terminal Button
9 mm
Cable binder
(accessory)
CUse the cable binder (accessory) to
secure the DC cable (double-coated
area) to the main monitor.
D Make sure to replace the terminal cover.
3
Hang hook (a) on the DIN rail (A).
Pull and hold the lever down (B).
Wiring from
doorphone
Important:
Do not connect the power cable.
(Damage may occur.)
Mount the main monitor to the mounting bracket.
3-1 Line up the tab on the bottom of the bracket with the groove on the main monitor (A).
3-2 Line up the tab on the top of the bracket with the groove on the main monitor, and
push the main monitor down until it is secure (B).
Secure hook (b) to the DIN rail (C).
Hook (a)
●●Write the name on the name plate as needed.
Image displayed on
main monitor:
Centre of
doorphone
Approx. 2,250
Approx. 1,600
View when looking
from above
Approx. 500
Approx. 1,450
Approx. 500
Approx. 170°
Approx. 650
(Units: mm)
Screw A
Wall
The area above and below the wide image is visible.
Image range
7
How to connect the DC cable:
Screws (B)
Make sure to replace the cable covers (A).
50
83.5
●●Connect the wires correctly according to "Wiring schematic
diagram".
A
(Units: mm)
Vertical, flat wall
Attach in the order described below so that hook (b) is positioned at the bottom.
Approx. 500
Approx. 500
mm
Connect the DC cable and wires.
32 mm
Attach to the DIN rail
Image range:
Approx. 900
Approx. 550
2
12 mm
*1
Image range
Centre of
doorphone
82.5
Hole in wall
Screws
(locally procured)
Cable binders (accessory)
5
Right
Down
DC cable

Approx. 85°
20 cm
●●Install the mounting bracket on a vertical
flat wall.
B Loosen screw B and push in the wires of
the DC cable to the terminal connectors
(non-polar), then tighten the screws.
●●Recommended torque:
0.8 N·m {8.2 kgf·cm}
Screws
3-1 Loosen the screws.
3-2 Push in the wires to the terminal connectors (non-polar), then tighten the screws.
4
m
Mounting bracket
Attach the mounting bracket to the wall
securely.
Bare wire at tip
Image range:
Approx. 900
Image range
Centre of
doorphone
Approx. 1,450
Insert the cables firmly all the way
into the terminals.
If the cables are not inserted all
the way, heat may be generated.
AC cable
*1
Terminals for the electric locks
●●Recommended torque: 0.5 N·m {5.1 kgf·cm}
●●Maximum torque:
0.7 N·m {7.1 kgf·cm}
20 c
Installing the main monitor
CAUTION
<Rear view>
Approx. 170°
SD card
slot
60
Centre (default)
Centre (default)
Approx. 1,450
DC OUT terminal
●●Recommended torque:
-- AC terminal: 0.4 N·m {4.1 kgf·cm}
-- DC terminal: 0.45 N·m {4.6 kgf·cm}
Connect the wires.
Terminal for the
main monitor
20 cm
Main monitor
installation position
1
DC cable
binder hole
<Front view>
Approx. 550
Approx. 500
Approx. 1,450
<Bottom view>
Remove the screws (B) and then remove
the cable covers (A).
Screw A
Approx. 2,050
●●After deciding where to install the main monitor, attach
the mounting bracket in the location shown on the
right.
AC cable
binder hole
AC IN terminal
2
(Units: mm)
Centre of
doorphone
<Top view>
7 mm
2 mm hex wrench
(accessory)
Left and right (when looking from above)
Approx. 45°
Power supply unit (with cable covers
removed)
<DC cable>
25 mm
Use a hex wrench (accessory) to loosen screw A and remove the front panel of the doorphone.

●●For the following reasons, leave at least 20 cm of space
above, below, and to the left and right sides of the main
monitor:
--To prevent malfunction and sound cutting out
--To ensure SD cards can be inserted and removed,
20 c
and to make sure the reset button can be used m
(the SD card slot is on the side of the main monitor;
the reset button is on the bottom)
7 mm
*1 Only open the knockout holes as
required for the wiring.
Front panel
Up
Strip the AC/DC cables as follows:
<AC cable>
45 mm
37 mm
●●Install the mounting base on a vertical flat wall.
●●Place the main monitor in a location that your eyes are the same height as the centre
of the display.
Reset button
Connect the power supply unit (accessory) and AC/DC cables (locally procured).
Wall
Wire (locally procured)
■ About the installation position of the main monitor and mounting bracket
How to connect the power cable (AC/DC)
151 mm
Approx. 170°
Approx. 900
■ Precautions for wiring
●●Make sure you turn off the power at the breaker before performing any wiring work.
●●Always connect AC or DC cables to the appropriate connection terminals. Incorrectly
connecting the AC or DC cables may damage the power supply unit.
●●To prevent the power cables from disconnecting and to prevent electric shock, secure the
power cables using the cable binders (accessory) and attach the cable covers.
1
83.5 mm
Main monitor installation position
■ About the installation location
●●The device must be installed inside an electrical panel or cabinet.
●●A readily accessible disconnect device shall be incorporated external to the equipment.
-- External disconnect device must be certified and have a creepage and clearance distance
of 3 mm or more.
Flush mounting box (accessory)
Approx. 500
Approx. 1,450
1
Attach the mounting base to the wall securely.
Screws (locally procured) × 2
Approx. 2,000
Centre of
doorphone
●●On the bottom surface of the doorphone and the mounting base, there are holes to allow water
to drain. Do not cover them up when installing.
●●When existing wiring (such as chime wires) is used:
-- It may contain AC voltage that may cause electric shock and/or damage the product.
-- Never use the following types of wiring. Consult a qualified technician/dealer.
VL-V554
When set to wide (default)
Approx. 95°
Installing the power supply unit
82.7 mm
Installing the doorphone
Doorphone installation position
C
Hook (b)
Name plate
(accessory)
Screw A
●●Recommended torque:
0.35 N·m {3.6 kgf·cm}
B
Notes about electrical wiring
Make sure not to pinch the wires (as shown to the
right) on the mounting bracket when installing.
●●Do not forcibly attach to the mounting bracket.
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising