Panasonic EW3122 Operating Instructions

EU Representative: Panasonic Marketing Europe GmbH Hagenauer Straße 43 D-65203, Wiesbaden, Germany Legal Manufacturer: Matsushita Electric Works, Ltd. 33 Okamachi, Hikone, Shiga 522-8520, Japan Panasonic Oberarm-Blutdruckmessgerat Upper Arm Blood Pressure Monitor Bedienungsanleitung Operating Instructions Model No. EW3122 Lesen Sie diese Bedienungsanleitung vor Inbetriebnahme des Geräts vollständig durch und bewahren Sie sie sorgfältig auf. Before operating this device, please read these instructions completely and save this manual for future use. Avant d'utiliser ce dispositif, veuillez lire entièrement ces instructions et rangez soigneusement ce manuel pour le consulter par la suite. Prima di mettere in funzione questo apparecchio leggere completamente le presenti istruzioni, e conservare questo manuale per l'utilizzo futuro. Antes de utilizar este dispositivo, lea completamente estas instrucciones y conserve este manual para futura referencia. Перед использованием прибора, пожалуйста прочтите полностью эти инструкции и сохраните данное руководство для использования на будущее. Bu cihazi kullanmadan ónce litfen talimatlarin tamamint okuyunuz ve bu kullanim kilavuzunu daha sonra kullanmak üzere muhafaza ediniz. Bedienungsanleitung Operating Instructions Mode d'emploi Istruzioni d'uso Instrucciones de funcionamiento Инструкция по эксплуатации Kullanma Talimatlari DE1-22 EN1-22 FR1-22 [T1-22 ES1-22 RUS1-22 TR 1-22 Dear customer, congratulation to the purchase of Panasonic blood pressure monitor. For more than a decade, Matsushita has been providing blood pressure measuring device to our customers in Europe. The product you have purchased has passed our strict quality control, and we hope that this can help you manage your daily blood pressure. We wish you all the best for your health. PARTS IDENTIFICATION Please check the instrument. Pressure cuff plug Pressure cuff socket Display Set button 7 Cover Blood pressure indicator lamps Connector (for AC adapter) Body movement indicator lamp Adjust button Memory/Recall Tube button 2 Start/Stop button Memory/Recall button 1 Pressure cuff EN1 Bottom of main body Battery cover How to open the cover (1) Press lightly on the Open/Close button. (2) Open the cover while holding the Open/Close button pressed. Optional accessory OAC Adapter EW31225 — I A y Pressure cuff storage example OLarge Cuff (35cm - 42cm) EW3900 Open/Close button EN2 INSTALLING BATTERIES + Batteries are not included. Please purchase them separately. * Always use alkaline batteries. (Four AA-size LR6 alkaline batteries) Turn the main body over, press lightly on the A mark on the battery cover, and remove the cover by sliding it in the direction of the arrow. Battery cover Check the polarities of the batteries and install them correctly. 3 Replace the battery cover and slide it closed. CAUTION: Always follow the cautions printed on the batteries. Check the polarities of the batteries and install them correctly. Remove exhausted batteries promptly. If the product will not be used for a long time, remove the batteries. Batteries should be used before their expiration date. Use after the expiration date may result in injury or staining of the surrounding area due to generation of heat, bursting, or leakage. Replace batteries when: e The mark shown at left appears during use. e All displays are lit for a moment after the Start/Stop button is pressed, and then the display goes blank. e No display appears even if the Start/Stop button is pressed. XI e Approximately 500 measurements (approximately 5 months when measurements are taken 3 times per day) can be taken with a set of fresh Panasonic alkaline batteries (four AA-size LR6 batteries). (Measurement conditions: Room temperature 22°C; Pressurized to 170mmHg; Upper arm circumference: 30cm) e When batteries other than Panasonic alkaline batteries are used, battery life may be shorter. When manganese batteries or other alkaline batteries are used, battery life becomes as short as 1/6th the life of Panasonic alkaline batteries. e Be sure to replace batteries once a year. If battery replacement is delayed, damage due to battery leakage may occur. eo When replacing batteries, always use four fresh alkaline batteries of the same type from the same manufacturer. * When room temperature is low, battery life may become shorter. EN3 WHEN USING THE AC ADAPTER * Use only the exclusive AC Adapter (EW31225). (See p. 2.) 1 Insert the AC adapter plug into the connector on the side of the main body. 2 Plug the AC adapter fully into the AC outlet. CAUTION: Be sure to use only the exclusive AC adapter (sold separately). Use of other AC adapters could cause an accident. Caution when using only the AC adapter When no batteries are installed in the main body and the AC adapter is unplugged from the AC outlet or main body, the set date and time will be reset and deleted. Because of this, even when using the AC adapter, it is recommended that batteries be installed in the main body. When the AC adapter is used, power is supplied from the AC adapter, so virtually no power from the batteries is used. EN4 BEFORE STARTING MEASUREMENTS Setting the date and time * Please set the date and time before taking the first measurement after purchasing the blood pressure monitor or after changing the batteries. e Although measurements can be taken without setting the date and time, if measurements are taken without performing these settings, the date and time will not be stored. e Please read the "Caution when using only the AC adapter" on p. 4. 1 Press the Set button below the display. Bi PT 2 The date value will blink. 7 555) Set the date. [ / | 000 Press the Change button repeatedly to set the correct day. Set the month. © Press the Set button. The month value will blink. O Press the Adjust button repeatedly to set the correct month. Set the hour. © Press the Set button. The hour value will blink. © Press the Adjust button to set the correct hour. [ 8/1. 0:06) [ 8/3 090) Set the minute. © Press the Set button. The minute value will blink. © Press the Adjust button repeatedly to set the correct minute. (8/31 = 5:37) Press the Set button at the exact time the minute E/ = Г: m = changes tO finalize the datetime setting. 8/ 3 15:00 7 Press the Start/Stop button to switch Off the power. When the date or time are blinking, the clock is stopped. During leap years, 1/3 will be displayed on February 29. For this reason, reset the date to 29/2. ENS POSITIONING THE PRESSURE CUFF <>) 1 removethe. | pressure cuff from the main body. (See p. 2.) 2 Insert the plug into the socket. e Insert the pressure cuff plug all the way in. 3 Wrap around upper arm. e Position the tube outlet so that it is on the palm side of the arm in line with the little finger of the hand. e Wrap around bare arm. NN f The blood pressure monitor can be used by wrapping the cuff on either upper arm. However, since it has been said that the difference in blood pressure between the left and right arms may be around 10mmHg, be sure to always use the same am for measurements. В Fasten so that there is no gap between the cuff and the arm, but be careful that the cuff is not too tight. e Be careful not to catch your clothes when wrapping the cuff. (Doing so may lead to Approximately 2 to 3cm from lower accuracy.) inside of elbow + Press the tape fastener down well. ENG FOR ACCURATE MEASUREMENTS Take measurements while sitting quietly and relaxing. 1 Rest your elbows on a table, etc. Position your arm so that the pressure cuff is at the same height as your heart. 3 Position your hand palm upward, and relax your hand. Take measurements using the upper arm on the same side in the same position at the same time every day. e Measurement values will vary according to the height of the pressure cuff. e Take measurements in the morning immediately after you wake up, when there is no urge to urinate. If this is difficult, take measurements before breakfast and before you have moved a lot. Relax and sit in a natural posture when taking measurements. e Always sit quietly for approximately 4 to 5 minutes before taking measurements. Relax your body, arm, and fingers and do not move their muscles. Do not talk while taking measurements. Do not use a cellular phone near the main body. During measurement, do not touch the main body or the tube. [CAUTION] Keep away from cellular telephones and other sources of electromagnetic radiation. Failure to do so could result in malfunctioning. EN7 CAUTIONS DURING MEASUREMENTS In the following situations, accurate measurements cannot be taken. OWithin 1 hour of eating or drinking alcohol Olmmediately after drinking coffee or tea, or smoking Olmmediately after exercising or taking a bath -Wait at least 20 minutes and take a measurement while staying quiet. Oln a moving vehicle Oln cold places -Take measurements at ambient temperatures of 10°C to 40°C. OWhen you need to urinate -Wait several minutes after urinating before taking measurements. ENS TAKING A READING Measurement y Los ee, CO CO. > e, Las | [ JN | | LL | JN The entire display will light for approximately 1 second. e |[fthere is air left in the pressure cuff, the fully lit time will be longer. Beep Beep Beep Beep EN9 Press the Start/Stop button. e The pressure cuff will automatically be pressurized and a measurement will be taken. 87 3530 ! ЖЖ e If your body moves during Jeu uy, у The heart mark will blink when pulse is detected during pressurization. measurement, the body movement ( “| indicator lamp will blink. (See p. 10.) dV “<A When measurement has been completed, a series of beeps will sound and the blood pressure and pulse values will be displayed. [EYE] Normal-High Normal Hypertension Normal-High Normal e Pressure will be automatically released from the pressure cuff. e The blood pressure indicator lamps will light (for approximately 6 seconds). e |fthe measured value is in the high blood pressure region, the values will blink (for approximately 6 seconds). (For how to read the blood pressure display, see p. 11.) e The (AM marks will light. e The (M) mark will blink. (For storing measurement values, see p. 12.) * The pulse rate value is the beats per minute calculated based on the pulse rate during measurement. To switch off the blood pressure monitor, PreSS the Start/Stop button. If you forget to switch it off, the blood pressure monitor will switch off automatically after approximately 5 minutes. TAKING A READING (continuep) About the body movement indicator function If your arm (to which the pressure cuff is attached), etc. moves during measurement (such as if you unconsciously bend your elbow), it may not be possible to take measurements correctly. e The body movement indicator function uses the body movement indicator lamp and a warning sound to tell you when movement has occurred or when excessive pressure has been applied to the pressure cuff during measurement. e If the body movement indicator lamp blinks, return your arm to the correct posture. (See p. 7.) e When body movement has been detected, the body movement indicator lamp will blink when the blood pressure judgment display appears. (The lamp will also blink when measurements for which movement was detected are stored and later recalled.) Body movement indicator lamp display O Blinking O Lit Warning sound Beeeep beeeep (long buzzer sounds) Beep beep (short buzzer sounds) Explanation Body movement was detected. e You unconsciously bent your elbow. e The upper arm became very tense. e You moved your arm. e Etc. Return to the proper posture. (See p. 7.) A movement which will cause large differences in measurement values occurred. e Body movement was large. e Body movement occurred several times. e Arm movement was large. Remeasure (Remeasure mark E is shown.) * It will also be lit in the following cases: ¢ Pressure cuff tape fastener became unfastened. e Tube came out. e Etc. (For details, see p. 21.) * This function is intended to help ensure correct measurements. (See p. 18.) Even if the remeasure mark does not appear (or body movement indicator lamp does not light), it is recommended that 2 or 3 measurements be taken in a quiet condition for best results. EN10 Reading the blood pressure display Whether the systolic and diastolic blood pressure values are in the high blood pressure region or normal blood pressure region are judged based on the WHO/ISH (World Health Organization/International Society of Hypertension) blood pressure classifications, and the blood pressure value blinks if required. WHO/ISH blood pressure Lamp color classifications™ Systolic (mmHg) (re blood pressure mild hypertension, moderate Orange hypertension, severe hypertension) 140 Yellow Borderline 130 hypertension Green Normal — 85 90 Diastolic (mmHg) e If the measured 873-1530) blood pressure value LE, =‘ , is in the high blood { (М © Systolic blood pressure: i ha 140mmHg or higher pressure region, the : values will blink for ¢ Diastolic blood pressure: approximately 6 90mmHg or higher seconds. (Only immediately after measurement) If measurements could not be taken properly & 3 15301 The remeasure mark E will be displayed. When taking successive measurements, press the Start/Stop button to switch off the blood pressure monitor once and stay quiet for 4 to 5 minutes, and then take the next measurement. Nu ана IM Advice: In general, blood pressure measurements are lower for the second measurement because you are less nervous and are more tranquil. For people who easily get tense, measuring twice each time is very effective. When two measurements are taken, normally the smaller measurement is stored. When taking two measurements, always stay quiet for 4 to 5 minutes after the first measurement before taking the second measurement. *1 1999 World Health Organization-International Society of Hypertension Guidelines for the Management of Hypertension EN11 STORING MEASUREMENT VALUES This product can separately store 42 measurements each for two persons. After measurement, the (À À will light. Press the Memory/Recall E. button with the number ко Normal-High yo corresponding to the person for which “awd | Measurements should be stored. Normal-High Normal 1 Example: Person A: Press myr Person B: Press mor Storing is completed. e Up to 42 measurement values can be stored. When the memory is full and additional values are stored, the oldest value in memory will be deleted and the new value will be stored. a © If measurements could not be taken properly NE (the E mark is shown instead of the blood a pressure value), measurement values cannot Normal be stored. However, even if the £ mark is shown for the pulse value, the blood pressure value will still be stored. Number of stored data To erase all measured values stored in memory: 1. Press the Memory/Recall button for the person whose data you want to delete. The stored measurement values will be displayed. 2. Press the same Memory/Recall button again, and hold it pressed until the measurement values disappear (approximately 3 seconds or more). * It is not possible to erase single measurement values. To switch off the blood pressure monitor, press the Start/Stop button. e |f you forget to switch it off, the blood pressure monitor will switch off automatically after approximately 5 minutes. EN12 RECALLING STORED MEASUREMENT Measurements can be recalled after measurement is completed or after the power has been switched off. If no measurement values are stored, no value will be shown. (ih) 1 Press the Memory/Recall button for the person whose data you want to recall. Panasonic ) The average of all measured values in memory will be Shown. e TI mark will be shown at the bottom of the display. e For example, if 42 measured values are stored, the average of the 42 measurements Will be shown. (If only 1 measurement is 1 ry ñ stored, the KT mark will not be shown.) a The blood pressure indicator lamps will light mmHg DIA. E mmHg / Plus/min. sus. | 000 1 | vv (for approximately 6 seconds). Press the Memory/Recall button again. A Each time you press the Memory/Recall button, the previously stored measurement values will be ww shown in order, starting with the newest data. e The blood pressure indicator lamps will light (for approximately 6 seconds). e |f your body moves during measurement, the body movement indicator lamp will blink (for approximately 6 seconds). Press the Memory/Recall button lightly for only a short time. If you hold the button pressed for approximately 3 seconds or longer, all data in memory will be erased, so please be careful. e If you forget to switch it off, the blood pressure monitor will switch off automatically after approximately 30 seconds. 3 To cancel measurement value recall, press the Start/Stop button. EN13 AFTER USE/SPECIFICATIONS Storage Unplug the plug from the main body. Roll up the pressure cuff loosely, and Store the tube inside the pressure cuff. e Do not wrap the tube around the main body, etc. Doing so may result in excessive force on the tube, and may result in a malfunction. e Be careful not to bend the tube. Put the pressure cuff in the main body and close the cover. Specifications DC 6V 4 x 1.5V (LR6/AA/Mignon/alkaline) AC 100-240V 50/60Hz (when using optional AC adapter) Display Digital LCD Measurement method | Oscillometric system Blood pressure: 0 to 280mmHg Pulse rate: 30 to 160 beats per minute Blood pressure: Within +3mmHg Power source Measurement range Accuracy Pulse rate: Within +5% Operation temperature / o humidity range 10 to 40°C, 30 to 85% RH Storage temperature/humidity -10 to 60°C, 10 to 95% RH range Measurable arm Approx. 20 to 34cm circumference pprox. Weight Approx. 530g (not including batteries) Dimensions 17.9 x 17.1 x 9.3cm EN14 MEASUREMENT ACCURACY General This blood pressure measurement device complies with the European regulations (EU council directive 93/42/EEC dated June 14, 1993) and bears the CE mark "CE 0197". The quality of the device has been verified and it confirms to the following standards: EN 1060-1 (Dec. 1995) Non-invasive sphygmomanometers General requirement Non-invasive sphygmomanometers Supplementary requirements for electromechanical blood pressure measuring systems Non-invasive sphygmomanometers Test procedures to determine the overall system accuracy of automated non-invasive sphygmomanometers. EN 60601-1-2 (Nov. 2001) Electromagnetic compatibility and safety for medical electrical equipment EN 1060-3 (Sep. 1997) EN 1060-4 (Sep. 2004) The CE mark serves to facilitate the free movement of goods between the member countries of the EU. Panasonic ensures accurate measurement The seal confirms that each device has been checked for accurate measurement at the Matsushita plant. It is CALIBRATED UNTIL recommended that the device be recalibrated every 3 years starting with the year printed on the seal. 2008 When the device has been repaired or the seal has been rendered illegible, the accuracy of the device should be assumed to be inaccurate. In such cases, it is recommended that the device be submitted for recalibration. EN15 Q&A Why are the blood pressure values measured at home different from those measured at the doctor's office? A Blood pressure varies 24 hours a day. In addition, it can change greatly depending on the weather, your mental state, exercise, etc. In particular, there is the phenomenon of "White uniform hypertension” at doctor's offices, where the blood pressure measured in a doctor's office is higher because of stress or worry. In addition, if the blood pressure measured at home is sometimes higher and sometimes lower than the blood pressure measured at the doctor's office, the following can be considered. Please pay attention to these points when taking measurements. @ ls the pressure cuff wrapped firmly? e Make sure that the pressure cuff is not wrapped too loosely or too tightly. e Is the pressure cuff wrapped around the upper arm? Make sure it is not partly covering the elbow. For how to wrap the pressure cuff correctly, refer to p. 6. O Do you feel worried or irritated? Before taking measurements, take 2 or 3 deep breaths and relax to stabilize blood pressure. In addition, it is recommended that you sit quietly for about 4 to 5 minutes before taking measurements. EN16 Why are measured blood pressure values different each time | take a measurement? @® Blood pressure changes even within a single day, and it is different depending on the measurement posture. Because of this, when taking measurements, be sure to always take measurements under the same conditions. For persons taking blood pressure medication, blood pressure may change greatly due to the effects of the medication. When taking 2 measurements in succession, be sure to stay quiet for 4 to 5 minutes after the first measurement before taking the next measurement. Q Why are the measured values different for the left and right arm? It is said that differences in blood pressure values between the left and right arms may be around 10mmHg. The blood pressure can be measured in either the left or right arm, but all measurements should be taken using the same arm. EN17 Q Even though the arm was moved, the body movement indicator light did not come on. A The body movement indicator function tells you that the elbow was bent or that excess pressure was applied to the pressure cuff. Because of this, if the movement resulted in no effect on the pressure cuff (such as lightly twisting your arm, bending your wrist, etc.), the indicator will not come on. If you still feel concerned about it, please take another measurement. Q When the body movement indicator lamp became lit, | returned my arm to the correct measurement position, but the measured value was higher than it always has been. A The body movement indicator lamp is intended as only a measurement method indicator. If you returned to the correct posture after the body movement indicator lamp became lit but the measured blood pressure is higher or lower than normal, please take another measurement. The following possible causes can also be considered: e Are measurements being taken properly (how cuff is wrapped, measurement posture, etc.)? Refer to pages 6 and 7 when taking measurements. Were measurements taken immediately after smoking? Were measurements taken when you were feeling irritated? Were measurements taken in a cold environment? Are you a person who has low pulse changes? If you feel concerned about it, please wait 4 to 5 minutes and then take another measurement. EN18 CARING FOR THE DEVICE Please do not attempt to disassemble, repair or modify the device. This may cause fire or cause the device to malfunction. It may also lead to injury. Do not use excessive force on the device. Do not drop the device. Measurements may be impaired if the device is used close to televisions, microwave ovens, X-ray equipment or other devices with strong electrical fields. Please measure your blood pressure at a sufficient distance from such devices or switch them off. The cuff may lose some of its elasticity at temperatures below 0°C. If the device is exposed to such extreme temperatures, it is a good idea to leave it until it warms up to room temperature before taking the next measurement. As a basic principle, the device should not be exposed to extreme conditions (cold, heat, humidity, dust). Do not allow dust or other foreign objects to enter the device as this may cause it to malfunction. Cleaning the device e Do not use anything other than a cloth with warm water and a little soapy to wipe the device. e Do not use thinners, benzene, or alcohol on the device as this may cause discoloration and cracks. e Cuff can not be washed. Storage ¢ Avoid exposing the device to high temperatures, high humidity and direct sunlight as this can cause the device to malfunction. Long-term storage e Remove the batteries before storing the device for long periods of time. Failure to do so may result in the batteries leaking, which may cause the device to malfunction. EN19 FOR YOUR SAFETY Always follow your physician's instruction when taking medication. Please consult your doctor as to the most appropriate time to measure your blood pressure if you are receiving medication. People with cardiac pacemakers, cardiac arrhythmia, vascular constriction or liver disorders as well as diabetics should consult their doctor before measuring their blood pressure themselves, since different values may be measured in such cases. The same also applies during pregnancy. The Diagnostec is no toy for children! In case you measure your child's blood pressure, always consult your doctor since the data cannot be compared with the standard adult's data. EN20 TROUBLESHOOTING Display Status before error Cause and solution Remeasure mark E is displayed. B/ 3 15:30 IM > > a Were measurements Pressurization to more than p> | taken according to the 280mmHg was performed. proper procedure and in the correct posture? Pressure decreased suddenly |p See p. 6 and 7. and the remeasure mark E appeared. D | Was the Measurement was taken to pressurization uf 20mmHg and then the > wrapped properly? remeasure mark E appeared. See p. 6. The heart mark Y blinked only a > Tube may not be few times or not at all. after waiting several dozen seconds. connected sufficiently. Check Pressurization doesn't occur even > the tube connection. See p. 6. Symptom Possible cause + Position of pressure cuff is low. dE » Pressure cuff is not wrapped correctly. Systolic or diastolic blood pressure D |+ Poston of pressure o high, y valu Is high or low + You moved or talked while measurements were being taken. See p. 6 and7. Blood pressure value is abnormally > + Posture is different for each measurement. high or low. See p. 7. № : etn om that measured D | * Blood pressure varies in response to minute changes in your mental y e doctor state, such as your reaction to a doctors presence. Measurement values are different > o Sit quietly for 4 to 5 minutes and then take another measurement. with each measurement. See p. 7. No display appears even when the > StarSiop bution pressed + Batteries are exhausted. When the Start/Stop button was e Batteries are installed with the polarities wrong. pressed, all displays became lit and | > Seep. 3. then the display disappeared. Body movement indicator lamp blinks > + Arm was moved. during measurement. See p. 10. > Even though the arm was not moved, e The body movement indicator lamp may respond when the arm the body movement indicator lamp | [>| becomes tense. Relax all tension in the arm when taking blinks. measurements. See p. 7. Take it to the store where it was Instrument s broken. > purchased for testing and repairs. EN21 If problem continues If problem continues Ask your doctor for advice. IMPORTANT SAFETY INSTRUCTIONS * Before using this instrument, please read the "IMPORTANT SAFETY INSTRUCTIONS" and be sure to use the instrument properly. * The cautions in this section are intended to instruct you in the proper use of this instrument and prevent danger or injury to yourself or other people. All of the cautions contain important information regarding safety and must be followed. WARNING: Failure to follow the caution may result in death or serious injury of people. CAUTION: Failure to follow the caution may result in injury to people, or in damage to property. WARNING: o Persons with serious obstructions of blood flow in the arm should consult a doctor before using this instrument. Failure to do so may result in deterioration of physical condition. e When cleaning, unplug the AC adapter from the AC outlet before cleaning. Also, do not plug in or unplug the AC adapter with wet hands. Doing so may result in electric shock or fire. e Do not let this product be used by children. e Do not let this product be used by people who cannot express their feelings, or who cannot operate the product for themselves. Such use may result in an accident or injury. e Do not spill water on the main body or AC adapter. Doing so may cause electric shock, short-circuiting, or product damage. e Do not use the AC adapter if it is damaged or if it plugs into the AC outlet loosely. Doing so may result in electric shock or short-circuiting. CAUTION: e Do not make judgments yourself regarding the measurement results or self-treat yourself. e Take measurements according to your doctor's instructions and have your doctor do the diagnosis. e Take medicine according to your doctor's instructions. e Do not use for purposes other than the measurement of blood pressure. Doing so may result in an accident or malfunction. e Never modify the product, or disassemble or attempt to repair it yourself. Doing so may result in fire or in injury due to abnormal operation. SAVE THESE INSTRUCTIONS EN22
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
Download PDF
advertisement