Aeg C502D-ML/GB User Manual
Below you will find brief information for Cooker hood 502 D. The Cooker hood 502 D with its multiple fan speeds and filter options, ensures clean and fresh air in your kitchen. It has a metal grease filter that can be washed either in the dishwasher or by hand. Charcoal filter can also be used for recirculation mode. It is important to clean the cooker hood and replace filters regularly as grease buildup can be a fire hazard.
PDF
Document
Advertisement
Advertisement
502 D Cooker hood Operating and Installation Instructions EM ST SY Y A N O M K G E R O IN D E A M 2 Printed on recycled paper. AEG – putting words into action. Contents Electrical connections .......................................................... 4 Safety warnings for electricians .............................................. 4 Appliances with 2 wires .......................................................... 5 Safety warnings for kitchen unit installer ................................ 6 General details ........................................................................ 7 Extractor version ..................................................................... 7 Filter Version ........................................................................... 8 Description of the appliance ................................................ 9 Technical details ................................................................... 9 Fixing the hood ..................................................................... 10 Safeting warnings for user .................................................... 11 Hood operation ..................................................................... 12 Care and maintenance ........................................................ 13 Metal grease filter ................................................................ 13 Charcoal filter ........................................................................ 14 Replacing the lamps ............................................................. 15 Cleaning ................................................................................ 15 Special accessories ............................................................ 16 What to do if ........................................................................ 16 Service and spare parts ..................................................... 17 Customer Care .................................................................... 17 Guarantee conditions ......................................................... 18 3 Electrical connections Safety warnings for electrician It must be ensured that the voltage and current indicated on the rating plate agree with the voltage of the user to electricity supply. If the appliance has been equipped with a mains lead with a moulded-on type plug, the following regulations must be comply with: The plug moulded on to the lead incorporates a fuse. For replacement, use a 5 amp BS1362 fuse. Only ASTA approved or certified fuses should be used. If the fuse cover/carrier is lost, a replacement cover/carrie must be obtained from an electrical goods retailer. If the socket outlets are not suitable for the plug fitted to the appliance, then the plug must be cut off and destroyed for safety reasons, and an appropriate plug be fitted. When wiring the plug ensure that all strands of wire are securely retained in each terminal. Do not forget to tighten the mains lead clamp on the plug. Electrical connections 230 V - using fixed power supply line with plug. 240 V - using fixed power supply line (Great Britain). Fuse rating 13 amps (The unit should only be connected up by an authorized electrician). See rating plate for further information. It is recommended that the socket for the plug is sited above the cooker hood or above the overhead cabinet. This has 2 advantages: 1) The socket is not visible. 2) The appliance can easily be unplugged when necessary. If a fixed connection is required the cooker hood should be connected by an electrical installer registered with a competent electricity company. An isolating device is to be provided on the fixed wiring side. Switches with a contact opening of more than 3mm apply as isolating devices. These include-automatic cut-out switches, fuses and contactors (VDE 0730, s. 7, Part1). 4 Electrical connection for the UK The appliance must be connected to fixed wiring with a double pole switched fused spur outlet with or without pilot lamp. Appliances with 2 wires We strongly recommend the appliance to be connected only by a qualified electrician who is a member of the NICEIC who will comply with the IEE and any local regulations. NOTE: The terminology “DOUBLE POLE” means that both the live and the neutral supplies are switched and disconnected at the same time. The terminations labelled SUPPLY are for the connection for the internal house wiring and the terminations labelled LOAD are for the appliance. IMPORTANT The wires of the mains lead supplied with this appliance are coloured in accordance with the following code: Blue-Neutral Brown-Live As the colours of the flexible cord of this appliance may not correspond with the coloured markings identifying the terminals in the plug, proceed as follows: The wire which is coloured brown must be connected to the terminal which is marked with the letter L or coloured red. The wire which is coloured blue must be connected to the terminal which is marked with the letter N or coloured black. BLUE (NEUTRAL) BROWN (LIVE) L LOAD L N SUPPLY LOAD FUSE ON DP 13A, 250V N SUPPLY 5 Safety warnings for kitchen unit installer When the unit is used in its extractor version, a sufficiently large ventilation hole must be provided, with dimensions that are approximately the same as the outlet hole. The air outlet must not be connected to chimney flues or combustion gas ducts. The air outlet must under no circumstances be connected to ventilation ducts for rooms in which fuel-burning appliances are installed. It is advisable to apply for authorization from the relevant controlling authority when connecting the outlet to an unused chimney flue or combustion gas duct. The air outlet installation must comply with the regulations laid down by the relevant authorities. National and regional building regulations impose a number of restrictions on using hoods and fuel-burning appliances connected to a chimney, such as coal or oil room-heaters and gas fires, in the same room. The local decree on fuel-burning systems specifies a maximum depression of 0.04 mbar in such rooms. Hoods can only be used safely with appliances connected to a chimney if the room and/or flat (air/environment combination) is ventilated from outside using a suitable ventilation hole approximately 500-600 cm2 large to avoid the possibility of negative pressure being created during operation of the hood. If you have any doubts, contact the relevant controlling authority or building inspector’s office. Since the rule for rooms with out fuel burning appliances is “air inlet should be same size as extractor outlet hole”, an aperture of 500-600 cm2, which is to say a larger hole, could reduce the performance of the extractor hood. If the hood is used in its filtering version (carbon filter), it will operate simply and safely in the above conditions without the need for any of the aforementioned measures. When the hood is used in its extractor function, the following rules must be followed to obtain optimal operation: — short and straight outlet hose — minimum number of bends in the outlet hose — Install hoses with an acute angle, always following a gentle curve only — hose as large as possible (100 mm Ø). 6 Failure to observe these basic rules will drastically reduce the performance and increase the noise levels of the extractor hood. When used as an extractor unit, the hood must be fitted with a 100mm diameter hose. If the fumes must be forced out through the wall, you must obtain a MKZ sizable wall exhaust pipe (with external exhaust and air intake), E-Nr.- 610 899 004 (Ø 120 mm) which is one of our optional parts. When installing the hood, make sure you respect the following minimum distance from the top edge of the cooking hob/ ring surfaces: electric cookers 650 mm gas cookers 700 mm coal and oil cookers 900 mm min. General details The hood is supplied as a ducted version, but may also be used in recirculation mode by inserting a charcoal filter (Special accessories). Extractor version The air is ducted out through a pipe which is connected to the outlet hole A (fig. 1) by means of a coupling flange B. To connect the hood to a wall box, you use hoses and wall boxes as offered on the AEG price list as optional extras. B A 1 7 Description of the appliance 1) Light switch 2) Motor switch 3) Work surface lamp 4) Grid 3 4 2 1 Technical details Model 502 D Net weight: Height Width Depth 5 kg 145 mm 520 mm 285 mm Absorbed power: 160W Motor: 1 x 120 W Lighting: 1 x 40 Watt Lengt of the cable: 110 cm Fan powers (speed), speed in compliance with DIN 44971 Speed: 1 Extractor version: 126 m3/h Filter version: 110 m3/h 2 3 149 m3/h 133 m3/h 185 m3/h 170 m3/h Flange: 100 mm Ø 9 Fixing the hood After having adjusted the hood for the version required, it may be installed. This appliance is designed for fitting in a cabinet or some other support. The opening to be made on the bottom of the wall-hung cabinet must correspond with the measurements shown in fig. 4 (495 X 260 mm). To fix the hood proceed as follows: a) remove the grid. b) Fit the hood into the opening. c) Secure the unit to the cabinet by screwing up screws through holes C (fig. 4). d) Replace the grid. C C 4 10 The hood is fitted with one variable speed motor. The most effective use of the hood is obtained by switching it on a few minutes before you start cooking and leaving it on a for approximately 5-15 minutes after having finished, thus ensuring that all that cooking odours are eliminated. Safety warnings for user Never leave a cooking hob or ring on without a pot or pan on top of it, to avoid the possibility of excess heat damaging the unit. Gas, oil or coal cooker flames in particular should never be left uncovered. Special care should be taken when using deep fat fryers since the oil in them can overheat and burst into flames. The risk of fat catching fire is increased when using dirty oil. It is extremely important to note that overheating can cause a fire. Never carry out any flambé cooking under the hood. Always disconnect the unit from the power supply before carrying out any work on the hood, including replacing the light bulb (take the cartridge fuse out of the fuse holder or switch off the automatic circuit breaker). It is very important to clean the hood and the grease filters at the recommended intervals. Failure to do so could cause grease deposits to build up, causing a fire hazard. 11 Hood Operation Controls The hood is fitted with a variable speed motor. The most effective use of the hood is obtained by switching it on a few minutes before you start cooking and leaving it on a for approximately 15 minutes after you have finished, thus ensuring all cooking odours are eliminated. The control switches are located on the unit’s front panel: the light switch (A) switches the hood lamp on and off; the motor switch (B) switches the cooking smoke and vapour extractor motor on and off, enabling you to select one of the three different speeds. B A 12 Care and Maintenance Before performing any maintenance operation, disconnect the hood from the electricity. Metal grease filter The hood has a metal grease filter. To clean the filter, proceed as follows: Open the grill by turning knob A (fig. 2). A A 2 Pull the two plastic stops B as shown by the arrows (fig. 5) and remove the metal filter. B B 5 You should take out the metal filter every four weeks and wash it either in the dishwashing machine or by hand. Clean the internal housing only with warm washing-up water — do not use any harsh cleaners, brushes, or abrasive. Soak metal filter cassette for about one hour in hot water with a greaseloosening cleaner, then rinse off thoroughly with hot water. Repeat the process if necessary. Re-fit the cassette when it is dry. Hand-washing Place metal filter cassette in dishwasher. Select most powerful washing program and highest temperature, at least 65° C. Repeat the process. Re-fit the cassette when it is dry. When washing the metal grease filter in the dishwasher a slight discoloration of the filter can occur. Dishwashing machine 13 Always turn off the electricity before replacing lamps! Replacing the lamps 1) Remove the grid (Fig. 2) in order to check the lamps and replace them if necessary. A A 2 2) Unscrew the lamps that do not work and replace them with 40W max lamps (E14). If the light does not function, check that the lamps are properly screwed before contacting a customers’ service centre. Warning: always disconnect the hood from the mains power supply before cleaning it. Never insert pointed objects in the motor’s protective grille. Cleaning Wash the outside surfaces using a mild detergent solution. Never use caustic detergents or abrasive brushes or powders. Only ever clean the switch panel and filter grille using a damp cloth and mild detergents. It is extremely important to clean the unit and change the filters at the recommended intervals. Failure to do so will cause grease deposits to build up that could constitute a fire hazard. Attention Failure to observe the rules for cleaning the appliance and changing and cleaning the filters may cause fire. Therefore, properly observing these instructions is highly recommended. 15 Special accessories See AEG price-list for wallbox and hose accessories. KF-Plus charcoal filter E-Nr. 942 118 620 What to do if If your appliance fails to work properly please carry out the following checks. 16 Symptom Solution The cooker hood will not start... Check that: The hood is connected to the electricity supply. Check that the fan speed control is set to 1, 2 or 3. The cooker hood is not working effectively.. Chec k that: The fan speed is set high enough for the task. The grease filters are clean. The kitchen is adequately vented to allow the entry of fresh air. If set up for recirculation, check that the charcoal filter is still effective. If set up for extraction, check that the ducting and outlets are not blocked. The cooker hood has switched off during operation... The safety cut-out device has been tripped. Turn off the hob and then wait for the device to reset. If the hood has been installed below the heights indicated in the installation instructions the motor will cut-out frequently which will damage the hood. If after all these checks, the problem persists, contact your local Service Force Centre, quoting the model and serial number. Please note that it will be necessary to provide proof of purchase for any in-guarantee service calls. In-guarantee customers should ensure that the above checks have been made as the engineer will make a charge if the fault is not a mechanical or electrical breakdown. Service and spare parts In the event of your appliance requiring service, or if you wish to purchase spare parts, contact your local AEG Service Force Centre by telephoning 08705 929 929 Your call will be automatically routed to the Service Centre covering your post code area. For the address of your local Service Force Centre and further information about Service Force, please visit the website at www.serviceforce.co.uk Please ensure that you have read the section „What to do if....“ as the engineer will make a charge if the fault is not a mechanical or electrical breakdown even the appliance is under warranty. Please note that proof of purchase is required for inguarantee service calls. Help us to help you Please determine your type of enquiry before writing or telephoning. When you contact us we need to know: • Your name • Address and post code • Telephone number • Clear and concise details of the fault • Name and model of the appliance* • E number* * This information can be found on the rating plate, which can be seen when the grease filters are removed. Customer Care For general enquiries concerning your AEG appliances, or for further information on AEG products, please contact our Customer Care Department at the address below or visit our website at www.aeg.co.uk Customer Care Department AEG Domestic Appliances 55-77 High Street Slough Berkshire SL1 1DZ Tel.: 08705 350 350* * calls to this number may be recorded for training purposes. 17 Guarantee conditions Guarantee Conditions AEG offer the following guarantee to the first purchaser of this appliance. 1. The guarantee is valid for 12 months commencing when the appliance is handed over to the first retail purchaser, which must be verified by purchase invoice or similar documentation.The guarantee does not cover commercial use. 2. The guarantee covers all parts or components which fail due to faulty workmanship or faulty materials. The guarantee does not cover appliances where defects or poor performance are due to misuse, accidental damage, neglect, faulty installation, unauthorised modification or attempted repair, commercial use or failure to observe requirements and recommendations set out in the instruction book.This guarantee does not cover such parts as light bulbs, removable glass-ware or plastic. 3. Should guarantee repairs be necessary the purchaser must inform the nearest customer service office (manufacturer`s service or authorised agent). AEG reserves the right to stipulate the place of the repair (i.e.the customer`s home, place of installation or AEG workshop). 4. The guarantee or free replacement includes both labour and materials. 5. Repairs carried out under guarantee do not extend the guarantee period for the appliance. Parts removed during guarantee repairs become the property of AEG. 6. The purchaser`s statutory rights are not affected by this guarantee. European Guarantee If you should move to another country within Europe then your guarantee moves with you to your new home subject to the following qualifications: - The guarantee starts from the date you first purchased your product. - The guarantee is for the same period and to the same extent for labour and parts as exist in the new country of use for this brand or range of products. - This guarantee relates to you an cannot be transferred to another user. - Your new home is within the European Community (EC) or European Free Trade Area. - The product is installed and used in accordance with our instructions and is only used domestically, i.e. a normal household. - The product is installed taking into account regulations in your new country. 18 Before you move please contact your nearest Customer Care Centre, listed below, to give them details of your new home.They will then ensure that the local Service Organisation is aware of your move and able to look after you and your appliances. France Senlis +33 (0) 3 44 62 29 29 Germany Nürnberg +49 (0) 800 234 7378 Italy Pordenone +39 (0) 800 117 511 Sweden Stockholm +46 (0) 8 672 5360 UK Slough +44 (0) 1753 219899 19 AEG Hausgeräte GmbH Postfach 1036 D-90327 Nürnberg http://www.aeg.hausgeraete.de © Copyright by AEG LI1ZDA Ed. 05/02 ">

Download
Just a friendly reminder. You can view the document right here. But most importantly, our AI has already read it. It can explain complex things in simple terms, answer your questions in any language, and help you quickly navigate even the longest or most compilcated documents.
Advertisement
Key features
- Multiple fan speeds
- Metal grease filter
- Charcoal filter option
- Easy to clean
- Safety features
Frequently asked questions
You can either wash it in the dishwasher or by hand. Soak the filter in hot water with a grease loosening cleaner, then rinse it thoroughly with hot water. Re-fit the filter when it is dry.
Electric cookers: 650 mm; gas cookers: 700 mm; coal and oil cookers: 900 mm min.
Remove the grid, unscrew the old lamps and replace them with 40W max lamps (E14). Always disconnect the hood from the mains power supply before cleaning it.
The hood has three fan speeds with corresponding air extraction rates. See technical details in document for exact values.