Dacor | IWD27 | Planning Guide for Microwave Drawer and Warming Drawer Combination | Dacor IWD27 Planning Guide for Microwave Drawer and Warming Drawer Combination

COMBINATION INSTALLATIONS
Revised 10/16/13 Page 1/1
Document # PGCI-022
EO, MOH or MOV Wall Oven/
Microwave In-A-Drawer/Warming Drawer
PLANNING
GUIDE
warning
•
Observe all governing codes and ordinances during
planning and installation. Contact your local building
department for further information.
•
All appliances must be installed in accordance with the
accompanying installation instructions.
All tolerances: +1/16” (+1.6 mm), -0, unless otherwise stated.
3/4” min. (1.9 cm)
Wall Oven Models
(A) Cutout Width
Single 27”
25 1/2” (64.8 cm)
Single 30”
28 1/2” (72.4 cm)
Microwave
Model No.
(B) Cutout Width
MMD24
22 1/4” (56.5 cm)
MMD30(V)
28 1/2” (72.4 cm)
240 Vac
wall oven
junction box
27 3/8”
(69.5 cm)
A
56 7/16”
(143.4 cm)
overall
stacked
height
1
2” min.
(5.1 cm)
120 Vac electrical
outlet for microwave
15 3/16”
(38.6 cm)
B
Warming Drawer
Models
(C) Cutout Width
27”
25 1/2” (64.8 cm)
30”
28 1/2” (72.4 cm)
1
1 1/4” min.
(3.2 cm)
120 Vac electrical outlet
for warming drawer
1
9 1/8”
(23.2 cm)
C
3/4” min.
(1.9 cm)
cutout dimensions
NOTE:
1.
2.
3.
3/4” (1.9 cm) support platform (flush with cutout).
See individual appliance Planning Guide pages to
determine overlays.
Spacing between appliances and drawers/doors shown
is minimum required to allow for ventilation and prevent
scraping. Additional space may need to be added for
appearance.
All specifications subject to change without notice.