Dacor | EWD24SCH | Combined Configuration Slide-In Cooktop - Side-by-Side Dual Warming Drawers?? PDF [0.25 MB] | Dacor EWD24SCH Combined Configuration Slide-In Cooktop - Side-by-Side Dual Warming Drawers?? PDF [0.25 MB]

COMBINATION INSTALLATIONS
Revised 11/19/09 Page 1/1
Document # PGCI - 012
Slide-In Cooktop/
Warming Drawers Stacked
PLANNING
GUIDE
All tolerances: +1/16”, -0, (+1.6 mm, -0) unless otherwise stated
warning
•
Observe all governing codes and ordinances during
planning and installation. Contact your local building
department for further information.
•
All appliances must be installed in accordance with the
accompanying installation instructions.
7 3/4" (197 mm)
Slide-in gas cooktops
Warming drawer
Warming drawer
1, 2
C
120 Vac
electrical
output
1, 2
Cooktop platform
1” (25 mm) Min.
thickness 3, 6
D
3, 6
C
3/4"
(19 mm) Min.3, 6
A
B
DRT/EG series cooktop with warming Drawers
(Stacked installation)
Dacor Models
(A) Cabinet Cutout
Width
(B) Min.
Cabinet Width
24 Inch wide models
22 1/2” (572 mm)
24 1/4” (616 mm)
27 Inch wide models
25 1/2” (648 mm)
27 1/4” (692 mm)
30 Inch wide models
28 1/2 (724 mm)
30 1/4” (768 mm)
(C) Cutout
Height
(D) Min. Gap
Between Cutouts
9 1/8” (232 mm)
1 1/4” (32 mm)
NOTES:
1.
2.
3.
4.
5.
6.
www.Dacor.com
Phone: (800) 793-0093
24” (610 mm) minimum interior cabinet depth.
3/4” (19 mm) support platform (flush with cutout).
Spacing may vary for warming drawers with a custom
front panel. See warming drawer installation instructions
for further details.
See individual planning guide pages to determine
overlays.
IWD, OWD and 36 Inch series models cannot be installed
above or below another warming drawer (any type).
Spacing between appliances and doors/drawers
is minimum required to allow for ventilation and to
prevent scraping. Additional space may be required for
appearance.
Specifications are subject to change without notice.
See installation instructions for additional details.