3 6" P R O F E SSI O NAL
R A N GE S & B AC KG UARDS
—
RGV2-364GD, RGV2-366, RDV2-364GD, RDV2-366
BGRV2-1236, BGRV2-3036, BGRV2-3036H models
PLANNING GUIDE
CONTENTS
36" Professional Range
RGV2-364GD, RGV2-366 , RDV2-364GD, RDV2-366
PAGE
in
mm
Key Design Decisions
5
17
Ventilation Requirements
6
18
Product & Cavity Dimensions
7
19
Clearance Dimensions
8
20
Cavity Preparation
9
21
Product & Cavity Dimensions
10
22
Clearance Dimensions
11
23
Cavity Preparation
12
24
36" Professional Range
RGV2-364GD, RDV2-364GD
36" Professional Range
RGV2-366, RDV2-366
CONTENTS (continued)
36" Professional Range Backguard
BGRV2-1236
PAGE
in
mm
Product Dimensions
36" Professional Range Backguard
BGRV2-3036
Product Dimensions
14
26
15
27
36" Professional Range Backguard
BGRV2-3036H
Product Dimensions
IMPERIAL
KEY DESIGN DECISIONS
36" Professional Range
1
2
3
INSTALL TYPE
REAR SURFACE
BACKGUARD OPTIONS
Model no:
RGV2-364GD, RGV2-366
RDV2-364GD, RDV2-366
BGRV2-3036H
ANGLED TRIM
(Supplied with
backguard)
BGRV2-1236
MIN 6"
CLEARANCE
WALL
COMBUSTIBLE
NO BACKGUARD
LOW THIN BACKGUARD
HIGH THICK BACKGUARD
WITH ANGLED TRIM
BGRV2-3036
CUSTOM
BACKGUARD*
MIN 30"
MAX 1/2"
NON COMBUSTIBLE
CUSTOM FABRICATED* BACKGUARD
ISLAND
HIGH THIN BACKGUARD
*Fabricated from non combustible materials only
NO BACKGUARD
DATE: 24.04.2018
IMPORTANT: Throughout this guide, dimensions may vary by ±2mm (1/16'').
Read the installation guide for detailed information on installing the product.
For full installation instructions and specifications visit fisherpaykel.com
VENTILATION REQUIREMENTS
36" Professional Range
1
2
INSTALL TYPE
HOOD SURROUND MATERIAL
Model no:
RGV2-364GD, RGV2-366
RDV2-364GD, RDV2-366
Specifications
23"
23"
Ventilation Unit
Hood
Blower
Ventilation Unit
Hood
MIN 30"
MAX 36"
Blower
Wall Installation
23'' Deep x Unit Width
600–1200 CFM
Island Installation
30'' Deep x Unit Width
600–1200 CFM
MIN 36"
Note: A suitable hood must be installed above the range. The above indicates
the minimum blower capacity recommended for hood ventilation.
WALL
NON COMBUSTIBLE
COMBUSTIBLE
30"
30"
MIN 30"
MAX 36"
MIN 36"
ISLAND
NON COMBUSTIBLE
COMBUSTIBLE
DATE: 24.04.2018
IMPORTANT: Throughout this guide, dimensions may vary by ±2mm (1/16'').
Read the installation guide for detailed information on installing the product.
For full installation instructions and specifications visit fisherpaykel.com
PRODUCT & CAVITY DIMENSIONS
36" Professional Range
B 35 7/8''
Model no:
RGV2-364GD-N, RGV2-364GD-L
RDV2-364GD-N, RDV2-364GD-L
Product Dimensions
C
A Overall height of range (from floor to cooktop,
excluding grates and vent trim)
29 1/8''
CABINET FACE FOR
INSTALLATION WITH
PROJECTING CONTROL PANEL
B Overall width of range
35 7/8''
C Overall depth of range (excluding handle and dials)
29 1/8''
D Depth from rear of chassis to cabinetry face - projecting
E Depth from rear of chassis to cabinetry face - flush
CABINET FACE FOR
INSTALLATION WITH
FLUSH CONTROL PANEL
F Height from countertop to top of pan supports
n
p
PLAN VIEW
G
F
1 3/4''
7 3/4''
I Height from countertop to top of door
8 1/16''
J Height from countertop to center of handle
9 7/16''
K Height from countertop to bottom of door
28 7/8''
L Height from countertop to bottom of chassis
35 1/4''
K J
I H
1 1/4''
35 9/16''
O Depth of handle (measured from front of door)
3 1/16''
P Depth of open door to cabinetry face - flush
19 1/8''
Q Adjustable feet height
TOP OF
COUNTERTOP
1 9/16''
H Height from countertop to bottom of control panel
N Width of handle (including standoffs)
DATUM :
25 1/8''
27 11/16''
G Height from countertop to top of vent trim
M Thickness of handle (not including standoffs)
C 29 1/8''
in
min 35 3/4''
max 36 3/4''
min 1/2''
max 1 1/2''
m
A
35 3/4'' 36 3/4''
o
l
Cavity Dimensions
Overall height of cavity
Overall width of cavity
Overall depth of cavity for projecting control panel
Overall depth of cavity for flush control panel
in
min 35 3/4''
max 36 3/4''
min 36''
max
25 1/8''
max
27 11/16''
DATUM : BOTTOM OF CHASSIS
Q
p
B 35 7/8''
D
E
INDICATES PRODUCT DATUM --------------------------------------------
FRONT VIEW
0
5
10
PROFILE VIEW
CABINET FACE FOR INSTALLATION
WITH FLUSH CONTROL PANEL
20
inches
CABINET FACE FOR INSTALLATION
WITH PROJECTING CONTROL PANEL
DATE: 24.04.2018
IMPORTANT: Throughout this guide, dimensions may vary by ±2mm (1/16'').
Read the installation guide for detailed information on installing the product.
For full installation instructions and specifications visit fisherpaykel.com
CLEARANCE DIMENSIONS
36" Professional Range
C
Model no:
C MINIMUM CLEARANCE:
MINIMUM CLEARANCE:
NEAREST VERTICAL
COMBUSTIBLE SURFACE
RGV2-364GD-N, RGV2-364GD-L
NEAREST VERTICAL
COMBUSTIBLE SURFACE
D
MINIMUM CLEARANCE:
COMBUSTIBLE SURFACE
RDV2-364GD-N, RDV2-364GD-L
Clearance Dimensions
E
MAXIMUM OVERALL DEPTH
OF OVERHEAD CABINETRY
CABINET FACE FOR
INSTALLATION WITH
PROJECTING CONTROL PANEL
D
CABINET FACE FOR
INSTALLATION WITH
FLUSH CONTROL PANEL
MINIMUM CLEARANCE:
NON-COMBUSTIBLE SURFACE
in
A Minimum width of ventilation hood installed above range
- not shown*
36''
B Minimum vertical distance between countertop and cabinet
extending above counter
18''
C Minimum clearance from left and right edge of range to
nearest vertical combustible surface
12''
D Minimum clearance from cooking surface to:
––combustible surface centered above the cooking surface
––non-combustible surface centered above the cooking surface
E Maximum overall depth of overhead cabinetry
54''
30''
13''
PLAN VIEW
B
MINIMUM CLEARANCE:
ADJACENT OVERHEAD CABINET
DATUM :
TOP OF COUNTERTOP
DATUM : BOTTOM OF CHASSIS
FRONT VIEW
0
5
10
PROFILE VIEW
CABINET FACE FOR INSTALLATION
WITH FLUSH CONTROL PANEL
20
inches
CABINET FACE FOR INSTALLATION
WITH PROJECTING CONTROL PANEL
INDICATES CABINETRY CLEARANCES --------------------------------INDICATES PRODUCT DATUM --------------------------------------------
DATE: 24.04.2018
IMPORTANT: Throughout this guide, dimensions may vary by ±2mm (1/16'').
Read the installation guide for detailed information on installing the product.
For full installation instructions and specifications visit fisherpaykel.com
CAVITY PREPARATION
36" Professional Range
RGV models
Model no:
RGV2-364GD-N, RGV2-364GD-L
RDV2-364GD-N, RDV2-364GD-L
FINAL POSITION OF
RANGE AGAINST WALL
Location of Electrical and Gas Supply
in
A Depth of supply area (ie maximum protrusion of
gas connection from wall)
2''
B Distance from right hand edge of range to supply area
ELECTRICAL
GAS
c
1 1/2''
C (RGV) Height of electrical supply area (from floor)
19''
D (RGV) Height of gas supply area (from floor)
12''
E (RGV) Width of supply area
d
5''
F (RDV) Distance from left hand edge of range to supply area
1 1/2''
G (RDV) Height of electrical and gas supply area (from floor)
6''
a
e
b
Specifications
Electrical
Supply
RGV Models
120 VAC, 60Hz
Max. Current Draw
Service
Electrical
Supply
Max. Current Draw
RDV models
Service
8 amp
15 amp circuit
RDV Models
120/240 VAC, 60Hz
21 amp
30 amp circuit
Gas – Natural
Connection
FINAL POSITION OF
RANGE AGAINST WALL
Supply Pressure
1/2” NPT Minimum 5/8” dia. flex line
Supply Pressure: 6” to 9” W.C.
Gas – LP
Connection
Supply Pressure*
11” to 14” W.C.
A regulator is required at the LP source to provide a maximum pressure
of 14” W.C. to the range regulator.
ELECTRICAL & GAS
g
1/2” NPT Minimum 5/8” dia. flex line
a
f
b
DATE: 24.04.2018
0
5
10
20
inches
IMPORTANT: Throughout this guide, dimensions may vary by ±2mm (1/16'').
Read the installation guide for detailed information on installing the product.
For full installation instructions and specifications visit fisherpaykel.com
PRODUCT & CAVITY DIMENSIONS
36" Professional Range
B 35 7/8''
Model no:
RGV2-366-N, RGV2-366-L
RDV2-366-N, RDV2-366-L
Product Dimensions
C
A Overall height of range (from floor to cooktop,
excluding grates and vent trim)
29 1/8''
CABINET FACE FOR
INSTALLATION WITH
PROJECTING CONTROL PANEL
B Overall width of range
35 7/8''
C Overall depth of range (excluding handle and dials)
29 1/8''
D Depth from rear of chassis to cabinetry face - projecting
E Depth from rear of chassis to cabinetry face - flush
CABINET FACE FOR
INSTALLATION WITH
FLUSH CONTROL PANEL
F Height from countertop to top of pan supports
n
p
PLAN VIEW
G
F
1 3/4''
7 3/4''
I Height from countertop to top of door
8 1/16''
J Height from countertop to center of handle
9 7/16''
K Height from countertop to bottom of door
28 7/8''
L Height from countertop to bottom of chassis
35 1/4''
K J
I H
3 1/16''
P Depth of open door to cabinetry face - flush
19 1/8''
m
A
35 3/4'' 36 3/4''
o
l
1 1/4''
35 9/16''
O Depth of handle (measured from front of door)
Q Adjustable feet height
TOP OF
COUNTERTOP
1 9/16''
H Height from countertop to bottom of control panel
N Width of handle (including standoffs)
DATUM :
25 1/8''
27 11/16''
G Height from countertop to top of vent trim
M Thickness of handle (not including standoffs)
C 29 1/8''
in
min 35 3/4''
max 36 3/4''
Cavity Dimensions
Overall height of cavity
Overall width of cavity
Overall depth of cavity for projecting control panel
Overall depth of cavity for flush control panel
min 1/2''
max 1 1/2''
in
min 35 3/4''
max 36 3/4''
min 36''
max
25 1/8''
max
27 11/16''
DATUM : BOTTOM OF CHASSIS
q
p
D
B 35 7/8''
E
FRONT VIEW
PROFILE VIEW
INDICATES PRODUCT DATUM --------------------------------------------
0
5
10
CABINET FACE FOR INSTALLATION
WITH FLUSH CONTROL PANEL
20
inches
CABINET FACE FOR INSTALLATION
WITH PROJECTING CONTROL PANEL
DATE: 24.04.2018
IMPORTANT: Throughout this guide, dimensions may vary by ±2mm (1/16'').
Read the installation guide for detailed information on installing the product.
For full installation instructions and specifications visit fisherpaykel.com
CLEARANCE DIMENSIONS
36" Professional Range
C
C
MINIMUM CLEARANCE:
NEAREST VERTICAL
COMBUSTIBLE SURFACE
Model no:
MINIMUM CLEARANCE:
NEAREST VERTICAL
COMBUSTIBLE SURFACE
RGV2-366-N, RGV2-366-L
D
MINIMUM CLEARANCE:
COMBUSTIBLE SURFACE
RDV2-366-N, RDV2-366-L
Clearance Dimensions
E
MAXIMUM OVERALL DEPTH
OF OVERHEAD CABINETRY
CABINET FACE FOR
INSTALLATION WITH
PROJECTING CONTROL PANEL
D
CABINET FACE FOR
INSTALLATION WITH
FLUSH CONTROL PANEL
MINIMUM CLEARANCE:
NON-COMBUSTIBLE SURFACE
in
A Minimum width of ventilation hood installed above range
- not shown*
36''
B Minimum vertical distance between countertop and cabinet
extending above counter
18''
C Minimum clearance from left and right edge of range to
nearest vertical combustible surface
12''
D Minimum clearance from cooking surface to:
––combustible surface centered above the cooking surface
––non-combustible surface centered above the cooking surface
E Maximum overall depth of overhead cabinetry
54''
30''
13''
PLAN VIEW
B
MINIMUM CLEARANCE:
ADJACENT OVERHEAD CABINET
DATUM :
TOP OF COUNTERTOP
DATUM : BOTTOM OF CHASSIS
FRONT VIEW
PROFILE VIEW
INDICATES CABINETRY CLEARANCES --------------------------------INDICATES PRODUCT DATUM --------------------------------------------
DATE: 24.04.2018
0
5
10
20
inches
CABINET FACE FOR INSTALLATION
WITH FLUSH CONTROL PANEL
CABINET FACE FOR INSTALLATION
WITH PROJECTING CONTROL PANEL
IMPORTANT: Throughout this guide, dimensions may vary by ±2mm (1/16'').
Read the installation guide for detailed information on installing the product.
For full installation instructions and specifications visit fisherpaykel.com
CAVITY PREPARATION
36" Professional Range
RGV models
Model no:
RGV2-366-N, RGV2-366-L
RDV2-366-N, RDV2-366-L
FINAL POSITION OF
RANGE AGAINST WALL
in
A Depth of supply area (ie maximum protrusion of
gas connection from wall)
2''
B Distance from right hand edge of range to supply area
ELECTRICAL
GAS
c
Location of Electrical and Gas Supply
d
1 1/2''
C (RGV) Height of electrical supply area (from floor)
19''
D (RGV) Height of gas supply area (from floor)
12''
E (RGV) Width of supply area
5''
F (RDV) Distance from left hand edge of range to supply area
1 1/2''
G (RDV) Height of electrical and gas supply area (from floor)
6''
a
e
b
Specifications
Electrical
Supply
RGV Models
120 VAC, 60Hz
Max. Current Draw
Service
Electrical
Supply
Max. Current Draw
RDV models
Service
5 amp
15 amp circuit
RDV Models
120/240 VAC, 60Hz
18 amp
30 amp circuit
Gas – Natural
Connection
FINAL POSITION OF
RANGE AGAINST WALL
Supply Pressure
1/2” NPT Minimum 5/8” dia. flex line
Supply Pressure: 6” to 9” W.C.
Gas – LP
Connection
Supply Pressure*
1/2” NPT Minimum 5/8” dia. flex line
11” to 14” W.C.
A regulator is required at the LP source to provide a maximum pressure
of 14” W.C. to the range regulator.
ELECTRICAL & GAS
g
a
f
b
DATE: 24.04.2018
0
5
10
20
inches
IMPORTANT: Throughout this guide, dimensions may vary by ±2mm (1/16'').
Read the installation guide for detailed information on installing the product.
For full installation instructions and specifications visit fisherpaykel.com
PRODUCT DIMENSIONS
36" Professional Range Backguard
NOT TO SCALE
BGRV2-1236
Model no:
BGRV2-1236
Product Dimensions
A Height of backguard above vent trim on range
c 35 7/8''
B Overall height of backguard
C Overall width of backguard
D Overall depth of backguard
DATUM : BACK OF PRODUCT
in
10 3/8''
15 15/16''
35 7/8''
1/2''
E Height of backguard below vent trim on range
5 9/16''
F Depth of backguard below vent trim on range
1/16''
PLAN VIEW
RGV2-366/
RDV2-366
(illustrated)
DATUM : BACK OF PRODUCT
d 1/2''
c 35 7/8''
A
10 3/8''
b
DATUM : TOP OF
VENT TRIM ON RANGE
e
f
PROFILE VIEW
0
5
10
FRONT VIEW
INDICATES PRODUCT DATUM --------------------------------------------
DATE: 24.04.2018
20
inches
IMPORTANT: Throughout this guide, dimensions may vary by ±2mm (1/16'').
Read the installation guide for detailed information on installing the product.
For full installation instructions and specifications visit fisherpaykel.com
c 35 7/8"
NOT TO SCALE
PRODUCT DIMENSIONS
36" Professional Range Backguard
BGRV2-3036
Model no:
DATUM : BACK OF PRODUCT
BGRV2-3036
Product Dimensions
d
f
A Height of backguard above vent trim on range
B Overall height of backguard
29 1/8"
C Overall width of backguard
35 7/8"
D Overall depth of backguard and racks
9 5/16"
E Depth of backguard
F Depth of racks
G Width of racks
g
RGV2-366/
RDV2-366
(illustrated)
H Distance from top of backguard to bottom of racks
PLAN VIEW
I Distance from bottom of backguard to bottom of racks
DATUM : BACK OF PRODUCT
c 35 7/8"
e
1/2"
in
28 3/8"
1/2"
8 13/16"
34"
10 15/16"
17 3/8"
J Distance from top of backguard to top of brackets
5 7/8"
K Height of backguard below vent trim on range
13/16"
L Depth of backguard below vent trim on range
1/16"
j
h
B
A
28 3/8"
i
DATUM : TOP OF
VENT TRIM ON RANGE
INDICATES PRODUCT DATUM --------------------------------------------
PROFILE VIEW
FRONT VIEW
l
0
5
k
DATE: 24.04.2018
10
20
inches
IMPORTANT: Throughout this guide, dimensions may vary by ±2mm (1/16'').
Read the installation guide for detailed information on installing the product.
For full installation instructions and specifications visit fisherpaykel.com
PRODUCT DIMENSIONS
36" Professional Range Backguard with Angled Vent Trim
B 35 7/8"
NOT TO SCALE
BGRV2-3036H
Model no:
DATUM : BACK OF BACKGUARD
BGRV2-3036H
f
Product Dimensions
c
h
PLAN VIEW
DATUM : BACK OF BACKGUARD
g
1 5/16"
in
30''
B Overall width of backguard
35 7/8''
C Overall depth of backguard and racks
10 3/8''
D Height of backguard
26 1/2''
E Height of angled vent trim
3 1/2''
F Depth of angled vent trim
2 7/8''
G Depth of backguard
i
RGV2-366/
RDV2-366
(illustrated)
A Overall height of backguard with angled vent trim
1 5/16'''
H Depth of racks
9 1/16''
I Width of racks
33 15/16"
J Distance from top of backguard to top of racks
5 3/8''
K Distance from bottom of angled vent trim to bottom of racks
18 7/8''
B 35 7/8"
Note: Angled vent trim supplied with BGRV2-3036H.
Remove flat vent trim and replace with angled vent trim.
j
d
A
30"
k
e
DATUM : BOTTOM OF ANGLED VENT TRIM
INDICATES PRODUCT DATUM --------------------------------------------
PROFILE VIEW
FRONT VIEW
f
DATE: 24.04.2018
0
5
10
20
inches
IMPORTANT: Throughout this guide, dimensions may vary by ±2mm (1/16'').
Read the installation guide for detailed information on installing the product.
For full installation instructions and specifications visit fisherpaykel.com
METRIC
KEY DESIGN DECISIONS
36" Professional Range
1
2
3
INSTALL TYPE
REAR SURFACE
BACKGUARD OPTIONS
Model no:
RGV2-364GD, RGV2-366
RDV2-364GD, RDV2-366
BGRV2-3036H
ANGLED TRIM
(Supplied with
backguard)
BGRV2-1236
MIN 152mm
CLEARANCE
WALL
COMBUSTIBLE
NO BACKGUARD
LOW THIN BACKGUARD
HIGH THICK BACKGUARD
WITH ANGLED TRIM
BGRV2-3036
CUSTOM
BACKGUARD*
MIN 762mm
MAX 24mm
NON COMBUSTIBLE
CUSTOM FABRICATED* BACKGUARD
ISLAND
HIGH THIN BACKGUARD
*Fabricated from non combustible materials only
NO BACKGUARD
DATE: 24.04.2018
IMPORTANT: Throughout this guide, dimensions may vary by ±2mm (1/16'').
Read the installation guide for detailed information on installing the product.
For full installation instructions and specifications visit fisherpaykel.com
VENTILATION REQUIREMENTS
36" Professional Range
1
2
INSTALL TYPE
HOOD SURROUND MATERIAL
Model no:
RGV2-364GD, RGV2-366
RDV2-364GD, RDV2-366
Specifications
584mm
584mm
Ventilation Unit
Hood
Blower
Ventilation Unit
MIN
762mm
MAX
914mm
Hood
914mm
Blower
Wall Installation
584mm Deep x Unit Width
600–1200 CFM
Island Installation
762mm Deep x Unit Width
600–1200 CFM
Note: A suitable hood must be installed above the range. The above indicates
the minimum blower capacity recommended for hood ventilation.
WALL
NON COMBUSTIBLE
COMBUSTIBLE
762mm
762mm
MIN 762mm
MAX 914mm
ISLAND
NON COMBUSTIBLE
914mm
COMBUSTIBLE
DATE: 24.04.2018
IMPORTANT: Throughout this guide, dimensions may vary by ±2mm (1/16'').
Read the installation guide for detailed information on installing the product.
For full installation instructions and specifications visit fisherpaykel.com
PRODUCT & CAVITY DIMENSIONS
36" Professional Range
B 911
Model no:
RGV2-364GD-N, RGV2-364GD-L
RDV2-364GD-N, RDV2-364GD-L
Product Dimensions
C
A Overall height of range (from floor to cooktop,
excluding grates and vent trim)
740
B Overall width of range
C Overall depth of range (excluding handle and dials)
CABINET FACE FOR
INSTALLATION WITH
PROJECTING CONTROL PANEL
CABINET FACE FOR
INSTALLATION WITH
FLUSH CONTROL PANEL
638
E Depth from rear of chassis to cabinetry face - flush
703
G Height from countertop to top of vent trim
H Height from countertop to bottom of control panel
n
PLAN VIEW
G
F
204
240
K Height from countertop to bottom of door
734
L Height from countertop to bottom of chassis
895
O Depth of handle (measured from front of door)
P Depth of open door to cabinetry face - flush
TOP OF
COUNTERTOP
Q Adjustable feet height
K J
I H
45
196
J Height from countertop to centre of handle
N Width of handle (including standoffs)
DATUM :
40
I Height from countertop to top of door
M Thickness of handle (not including standoffs)
C 740
911
740
D Depth from rear of chassis to cabinetry face - projecting
F Height from countertop to top of pan supports
p
mm
min 908
max 933
32
904
77
486
min 13
max 38
m
A
908 933
o
l
Cavity Dimensions
Overall height of cavity
Overall width of cavity
Overall depth of cavity for projecting control panel
Overall depth of cavity for flush control panel
mm
min 908
max 933
min 914
max 638
max 703
DATUM : BOTTOM OF CHASSIS
q
p
D
B 911
E
FRONT VIEW
PROFILE VIEW
INDICATES PRODUCT DATUM --------------------------------------------
0
100 200
400
millimetres
CABINET FACE FOR INSTALLATION
WITH FLUSH CONTROL PANEL
CABINET FACE FOR INSTALLATION
WITH PROJECTING CONTROL PANEL
DATE: 24.04.2018
IMPORTANT: Throughout this guide, dimensions may vary by ±2mm (1/16'').
Read the installation guide for detailed information on installing the product.
For full installation instructions and specifications visit fisherpaykel.com
CLEARANCE DIMENSIONS
36" Professional Range
C
C
MINIMUM CLEARANCE:
NEAREST VERTICAL
COMBUSTIBLE SURFACE
Model no:
MINIMUM CLEARANCE:
NEAREST VERTICAL
COMBUSTIBLE SURFACE
RGV2-364GD-N, RGV2-364GD-L
D
E
MINIMUM CLEARANCE:
COMBUSTIBLE SURFACE
MAXIMUM OVERALL DEPTH
OF OVERHEAD CABINETRY
CABINET FACE FOR
INSTALLATION WITH
PROJECTING CONTROL PANEL
D
CABINET FACE FOR
INSTALLATION WITH
FLUSH CONTROL PANEL
MINIMUM CLEARANCE:
NON-COMBUSTIBLE SURFACE
RDV2-364GD-N, RDV2-364GD-L
Clearance Dimensions
mm
A Minimum width of ventilation hood installed above range
- not shown*
914
B Minimum vertical distance between countertop and cabinet
extending above counter
457
C Minimum clearance from left and right edge of range to
nearest vertical combustible surface
305
D Minimum clearance from cooking surface to:
––combustible surface centred above the cooking surface
––non-combustible surface centred above the cooking surface
1372
762
E Maximum overall depth of overhead cabinetry
330
PLAN VIEW
B
MINIMUM CLEARANCE:
ADJACENT OVERHEAD CABINET
DATUM :
TOP OF COUNTERTOP
DATUM : BOTTOM OF CHASSIS
FRONT VIEW
0
100 200
400
millimetres
PROFILE VIEW
CABINET FACE FOR INSTALLATION
WITH FLUSH CONTROL PANEL
CABINET FACE FOR INSTALLATION
WITH PROJECTING CONTROL PANEL
INDICATES CABINETRY CLEARANCES --------------------------------INDICATES PRODUCT DATUM --------------------------------------------
DATE: 24.04.2018
IMPORTANT: Throughout this guide, dimensions may vary by ±2mm (1/16'').
Read the installation guide for detailed information on installing the product.
For full installation instructions and specifications visit fisherpaykel.com
CAVITY PREPARATION
36" Professional Range
RGV models
Model no:
RGV2-364GD-N, RGV2-364GD-L
RDV2-364GD-N, RDV2-364GD-L
FINAL POSITION OF
RANGE AGAINST WALL
Location of Electrical and Gas Supply
mm
A Depth of supply area (ie maximum protrusion of
gas connection from wall)
51
B Distance from right hand edge of range to supply area
ELECTRICAL
GAS
c
38
C (RGV) Height of electrical supply area (from floor)
483
D (RGV) Height of gas supply area (from floor)
305
E (RGV) Width of supply area
d
127
F (RDV) Distance from left hand edge of range to supply area
38
G (RDV) Height of electrical and gas supply area (from floor)
152
a
e
b
Specifications
Electrical
Supply
RGV Models
120 VAC, 60Hz
Max. Current Draw
Service
Electrical
Supply
Max. Current Draw
RDV models
Service
8 amp
15 amp circuit
RDV Models
120/240 VAC, 60Hz
21 amp
30 amp circuit
Gas – Natural
Connection
FINAL POSITION OF
RANGE AGAINST WALL
Supply Pressure
1/2” NPT Minimum 5/8” dia. flex line
Supply Pressure: 6” to 9” W.C.
Gas – LP
Connection
Supply Pressure*
1/2” NPT Minimum 5/8” dia. flex line
11” to 14” W.C.
A regulator is required at the LP source to provide a maximum pressure
of 14” W.C. to the range regulator.
ELECTRICAL & GAS
g
a
f
b
DATE: 24.04.2018
0 100 200
400
millimetres
IMPORTANT: Throughout this guide, dimensions may vary by ±2mm (1/16'').
Read the installation guide for detailed information on installing the product.
For full installation instructions and specifications visit fisherpaykel.com
PRODUCT & CAVITY DIMENSIONS
36" Professional Range
B 911
Model no:
RGV2-366-N, RGV2-366-L
RDV2-366-N, RDV2-366-L
Product Dimensions
C
A Overall height of range (from floor to cooktop,
excluding grates and vent trim)
740
B Overall width of range
C Overall depth of range (excluding handle and dials)
CABINET FACE FOR
INSTALLATION WITH
PROJECTING CONTROL PANEL
CABINET FACE FOR
INSTALLATION WITH
FLUSH CONTROL PANEL
638
E Depth from rear of chassis to cabinetry face - flush
703
G Height from countertop to top of vent trim
H Height from countertop to bottom of control panel
n
PLAN VIEW
G
F
204
240
K Height from countertop to bottom of door
734
L Height from countertop to bottom of chassis
895
O Depth of handle (measured from front of door)
P Depth of open door to cabinetry face - flush
TOP OF
COUNTERTOP
Q Adjustable feet height
K J
I H
m
A
908 933
o
l
45
196
J Height from countertop to centre of handle
N Width of handle (including standoffs)
DATUM :
40
I Height from countertop to top of door
M Thickness of handle (not including standoffs)
C 740
911
740
D Depth from rear of chassis to cabinetry face - projecting
F Height from countertop to top of pan supports
p
mm
min 908
max 933
Cavity Dimensions
Overall height of cavity
Overall width of cavity
Overall depth of cavity for projecting control panel
Overall depth of cavity for flush control panel
32
904
77
486
min 13
max 38
mm
min 908
max 933
min 914
max 638
max 703
DATUM : BOTTOM OF CHASSIS
q
p
D
B 911
E
FRONT VIEW
PROFILE VIEW
INDICATES PRODUCT DATUM --------------------------------------------
0
100 200
400
millimetres
CABINET FACE FOR INSTALLATION
WITH FLUSH CONTROL PANEL
CABINET FACE FOR INSTALLATION
WITH PROJECTING CONTROL PANEL
DATE: 24.04.2018
IMPORTANT: Throughout this guide, dimensions may vary by ±2mm (1/16'').
Read the installation guide for detailed information on installing the product.
For full installation instructions and specifications visit fisherpaykel.com
CLEARANCE DIMENSIONS
36" Professional Range
C
C
MINIMUM CLEARANCE:
NEAREST VERTICAL
COMBUSTIBLE SURFACE
Model no:
MINIMUM CLEARANCE:
NEAREST VERTICAL
COMBUSTIBLE SURFACE
RGV2-366-N, RGV2-366-L
D
E
MINIMUM CLEARANCE:
COMBUSTIBLE SURFACE
MAXIMUM OVERALL DEPTH
OF OVERHEAD CABINETRY
CABINET FACE FOR
INSTALLATION WITH
PROJECTING CONTROL PANEL
D
CABINET FACE FOR
INSTALLATION WITH
FLUSH CONTROL PANEL
MINIMUM CLEARANCE:
NON-COMBUSTIBLE SURFACE
RDV2-366-N, RDV2-366-L
Clearance Dimensions
mm
A Minimum width of ventilation hood installed above range
- not shown*
914
B Minimum vertical distance between countertop and cabinet
extending above counter
457
C Minimum clearance from left and right edge of range to
nearest vertical combustible surface
305
D Minimum clearance from cooking surface to:
––combustible surface centred above the cooking surface
––non-combustible surface centred above the cooking surface
1372
762
E Maximum overall depth of overhead cabinetry
330
PLAN VIEW
B
MINIMUM CLEARANCE:
ADJACENT OVERHEAD CABINET
DATUM :
TOP OF COUNTERTOP
DATUM : BOTTOM OF CHASSIS
FRONT VIEW
PROFILE VIEW
INDICATES CABINETRY CLEARANCES --------------------------------INDICATES PRODUCT DATUM --------------------------------------------
DATE: 24.04.2018
0
100 200
400
millimetres
CABINET FACE FOR INSTALLATION
WITH FLUSH CONTROL PANEL
CABINET FACE FOR INSTALLATION
WITH PROJECTING CONTROL PANEL
IMPORTANT: Throughout this guide, dimensions may vary by ±2mm (1/16'').
Read the installation guide for detailed information on installing the product.
For full installation instructions and specifications visit fisherpaykel.com
CAVITY PREPARATION
36" Professional Range
RGV models
Model no:
RGV2-366-N, RGV2-366-L
RDV2-366-N, RDV2-366-L
FINAL POSITION OF
RANGE AGAINST WALL
Location of Electrical and Gas Supply
mm
A Depth of supply area (ie maximum protrusion of
gas connection from wall)
B Distance from right hand edge of range to supply area
ELECTRICAL
GAS
c
51
d
38
C (RGV) Height of electrical supply area (from floor)
483
D (RGV) Height of gas supply area (from floor)
305
E (RGV) Width of supply area
127
F (RDV) Distance from left hand edge of range to supply area
38
G (RDV) Height of electrical and gas supply area (from floor)
152
a
e
b
Specifications
Electrical
Supply
RGV Models
120 VAC, 60Hz
Max. Current Draw
Service
Electrical
Supply
Max. Current Draw
RDV models
Service
5 amp
15 amp circuit
RDV Models
120/240 VAC, 60Hz
18 amp
30 amp circuit
Gas – Natural
FINAL POSITION OF
RANGE AGAINST WALL
Connection
Supply Pressure
1/2” NPT Minimum 5/8” dia. flex line
Supply Pressure: 6” to 9” W.C.
Gas – LP
Connection
Supply Pressure*
11” to 14” W.C.
A regulator is required at the LP source to provide a maximum pressure
of 14” W.C. to the range regulator.
ELECTRICAL & GAS
g
1/2” NPT Minimum 5/8” dia. flex line
a
f
b
DATE: 24.04.2018
0 100 200
400
millimetres
IMPORTANT: Throughout this guide, dimensions may vary by ±2mm (1/16'').
Read the installation guide for detailed information on installing the product.
For full installation instructions and specifications visit fisherpaykel.com
PRODUCT DIMENSIONS
36" Professional Range Backguard
NOT TO SCALE
BGRV2-1236
Model no:
BGRV2-1236
Product Dimensions
c 911
263
B Overall height of backguard
405
C Overall width of backguard
D Overall depth of backguard
DATUM : BACK OF PRODUCT
mm
A Height of backguard above vent trim on range
911
13
E Height of backguard below vent trim on range
142
F Depth of backguard below vent trim on range
1
PLAN VIEW
RGV2-366/
RDV2-366
(illustrated)
DATUM : BACK OF PRODUCT
c 911
d 13
A
263
b
DATUM : TOP OF
VENT TRIM ON RANGE
e
f
PROFILE VIEW
0
100
200
400
millimetres
FRONT VIEW
INDICATES PRODUCT DATUM --------------------------------------------
DATE: 24.04.2018
IMPORTANT: Throughout this guide, dimensions may vary by ±2mm (1/16'').
Read the installation guide for detailed information on installing the product.
For full installation instructions and specifications visit fisherpaykel.com
NOT TO SCALE
PRODUCT DIMENSIONS
36" Professional Range Backguard
c 912
BGRV2-3036
Model no:
DATUM : BACK OF PRODUCT
BGRV2-3036
Product Dimensions
d
f
720
B Overall height of backguard
740
C Overall width of backguard
D Overall depth of backguard and racks
E Depth of backguard
g
RGV2-366/
RDV2-366
(illustrated)
PLAN VIEW
DATUM : BACK OF PRODUCT
c 912
e 13
mm
A Height of backguard above vent trim on range
911
237
13
F Depth of racks
224
G Width of racks
864
H Distance from top of backguard to bottom of racks
278
I Distance from bottom of backguard to bottom of racks
442
J Distance from top of backguard to top of brackets
149
K Height of backguard below vent trim on range
20
L Depth of backguard below vent trim on range
1
j
h
B
A
720
i
DATUM : TOP OF
VENT TRIM ON RANGE
INDICATES PRODUCT DATUM --------------------------------------------
PROFILE VIEW
FRONT VIEW
DATE: 24.04.2018
l
0
100
k
200
400
millimetres
IMPORTANT: Throughout this guide, dimensions may vary by ±2mm (1/16'').
Read the installation guide for detailed information on installing the product.
For full installation instructions and specifications visit fisherpaykel.com
PRODUCT DIMENSIONS
36" Professional Range Backguard with Angled Vent Trim
B 912
NOT TO SCALE
BGRV2-3036H
Model no:
DATUM : BACK OF BACKGUARD
BGRV2-3036H
f
c
h
Product Dimensions
mm
A Overall height of backguard with angled vent trim
763
B Overall width of backguard
264
D Height of backguard
673
E Height of angled vent trim
i
PLAN VIEW
RGV2-366/
RDV2-366
(illustrated)
g
90
F Depth of angled vent trim
72
G Depth of backguard
33
H Depth of racks
230
I Width of racks
862
J Distance from top of backguard to top of racks
DATUM : BACK OF BACKGUARD
911
C Overall depth of backguard and racks
K Distance from bottom of angled vent trim to bottom of racks
136
480
B 912
33
Note: Angled vent trim supplied with BGRV2-3036H.
Remove flat vent trim and replace with angled vent trim.
j
d
A
763
k
e
DATUM : BOTTOM OF ANGLED VENT TRIM
INDICATES PRODUCT DATUM --------------------------------------------
PROFILE VIEW
FRONT VIEW
f
DATE: 24.04.2018
0
100
200
400
millimetres
IMPORTANT: Throughout this guide, dimensions may vary by ±2mm (1/16'').
Read the installation guide for detailed information on installing the product.
For full installation instructions and specifications visit fisherpaykel.com
IMPORTANT: The product dimensions and specifications
apply at the date of issue. Under our policy of continuous
product improvement, these dimensions and specifications
may change at any time. Dimensions may vary by ±2mm (1/16").
Please read the installation guide for detailed information
on installing the product or visit fisherpaykel.com.
April 2018