Dacor | DTCT365GWNG | Planning Guide | Dacor DTCT365GWNG Planning Guide

Dacor DTCT365GWNG Planning Guide
DTCT304, DTCT365, DTCT466
Revised 11/05/15 Page 1/3
Document # PG04-008
Distinctive 30”, 36” and 46” Wide
Drop-in Gas Cooktops
PLANNING
GUIDE
®
WARNING
Model DTCT304G
Observe all governing codes and ordinances during
planning and installation.
Contact your local building department for further
information. This appliance must be installed in
accordance with the installation instructions supplied
with the unit.
1 5/8 in (4.1 cm)
bottom of base
to cooking surface
30 in
(76.2 cm)
4 in (10.2 cm)
chassis height
All tolerances: ±1/16” unless otherwise noted.
21 in
(53.3 cm)
19 1/2 in *
(49.5 cm)
27 5/8 in *
(70.2 cm)
Model DTCT365G
* including raised embosses on sides of chassis 1 5/8 in (4.1 cm)
bottom of base
to cooking surface
36 in
(91.4 cm)
4 in (10.2 cm)
chassis height
21 in
(53.3 cm)
33 1/2 in *
(85.1 cm)
19 1/2 in *
(49.5 cm)
Model DTCT466G
4 in (10.2 cm)
chassis height
46 in
(116.8 cm)
* including raised embosses on sides of chassis
1 5/8 in (4.1 cm)
bottom of base
to cooking surface
21 in
(53.3 cm)
44 5/8 in *
(113.3 cm)
19 1/2 in *
(49.5 cm)
* including raised embosses on sides of chassis
All specifications subject to change without notice.
www.dacor.com
Phone: (800) 793-0093
4.22
DTCT304, DTCT365, DTCT466
Revised 11/05/15 Page 2/3
Document # PG04-008
Distinctive 30”, 36” and 46” Wide
Drop-in Gas Cooktops
®
Electrical Requirements
Gas Supply Requirements
WARNING
To prevent an electric shock hazard, the power supply must meet the
specifications stated below. It is the owner’s responsibility to make sure
that the electrical service meets electrical requirements and that the
electrical outlet has been properly installed by a licensed electrician.
◊
PLANNING
GUIDE
The cooktop is supplied with a factory installed, 40-inch,
three-prong, grounding electrical plug. It is connected to the
chassis at the bottom right rear corner.
◊
Ensure that the cooktop is correct for the gas being provided (natural
gas or LP gas). Also, if using the cooktop at an altitude above 4000
ft. (1219 m), make sure it is equipped for high altitude operation.
◊
Units equipped for LP operation have “LP” in the model number
listed on the product data label. See the figure Chassis Bottom for
the label location.
◊
Units equipped for high altitude operation have an “H” at the end of
the model number listed on the product data label.
◊
Check your local building codes for the proper method of installation.
In the absence of local codes, this appliance should be installed in
accordance with the National Fuel Gas Code ANSI Z223.1/NFPA 54.
◊
An external manual shut-off valve must be installed between the gas
inlet and the cooktop for the purpose of turning on or shutting off gas
to the appliance.
◊
The cooktop comes from the factory with a regulator in the shipping
carton. The regulator must be installed in the gas line that runs from
the cooktop gas inlet to the gas shut-off valve. Use only the regulator
provided.
◊
Models DTCT304G and DTCT365G have a 1/2-inch regulator.
Model DTCT466G has a 3/4-inch regulator, approved for connection
to a 1/2 inch house gas supply.
Refer to the figure Chassis Bottom below.
◊
The cooktop must be connected to a dedicated, grounded
three-prong electrical outlet installed by a licensed
electrician.
◊
The electrical installation, including the supply wire size and
grounding, must be done in accordance with National Electric
Code ANSI/NFPA 70* and local codes and ordinances. A copy of this standard may be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02269-9101
◊
The correct voltage, frequency, and amperage must be
supplied to the electrical outlet according to the product data
label located on the bottom of the chassis.
◊
See the table Gas and Electrical Requirements on this
page for reference.
◊
Be certain to choose an electrical outlet with easy access so
that the power cord may be disconnected if the unit needs
service.
The cooktop gas connection is located on the bottom of the cooktop,
in the back right corner as you face the front of the unit. See the figure
Chassis Bottom on this page.
Model Number
DTCT304G
DTCT365G
DTCT466G
DTCT304LP
DTCT365LP
DTCT466LP
Gas Type
Natural Gas
LP Gas
Manifold
Pressure
4” Water
column
10” Water
column
Min. Gas Supply
Pressure **
5” Water
column
11” Water
column
Max. Gas Supply
Pressure
1/2 psi
1/2 psi
Total Connected
Load
0.25 Amp.
(0.03 kW)
0.25 Amp.
(0.03 kW)
120 Vac,
60 Hz, 15 Amp.
120 Vac,
60 Hz, 15 Amp.
Circuit
Requirement
Gas and Electrical Requirements*
* The electrical and gas data on this page is for reference only. If the
above data does not agree with the product data label, use the data on
the product data label.
Product data label
3-prong
plug
Gas inlet
** The gas supply pressure for testing the regulator setting shall be at
least 1-inch water column (249 Pa) above the specified manifold pressure.
Chassis Bottom
All specifications subject to change without notice.
www.dacor.com
Phone: (800) 793-0093
4.23
DTCT304, DTCT365, DTCT466
Revised 11/05/15 Page 4/5
Document # PG04-008
Distinctive 30”, 36” and 46” Wide
Drop-in Gas Cooktops
®
PLANNING
GUIDE
Cabinet and Countertop Layout
WARNING
•
To reduce the risk of personal injury caused by reaching
over a hot appliance, avoid locating cabinet storage space
directly above the cooktop.
•
Failure to meet or exceed the maximum and minimum
dimensions/clearances stated in these instructions may
result in a fire hazard.
•
B
Follow the countertop manufacturer’s instructions regarding
the minimum corner radius, use of heat reflective tape,
reinforcement of corners, etc.
◊
Allow a minimum 1/4 in (6 mm) clearance between
•
the bottom of the cooktop chassis and
•
all combustible surfaces, including the edges and corners of drawers
that sit below the cooktop.
Carefully check the location where the cooktop will be installed.
For best performance, the cooktop should be placed away from
drafts that may be caused by doors, windows and heating and air
conditioning outlets.
◊
1/4” (6 mm)
min. clearance
to combustible
surfaces
Minimum Clearance for Hold-Down Brackets
This appliance is to be used in conjunction with a suitable vent hood
or approved Dacor downdraft.
CLEARANCE REQUIREMENTS
Model
B
DTCT304G
29 in (73.7 cm)
DTCT365G
35 1/4 in (89.5 cm)
DTCT466G
45 1/4 in (114.64 cm)
Model
A: Minimum
A: Recommended
DTCT304G
30 in (76.2 cm)
36 in (91.4 cm)
◊
Allow clearance for hold-down brackets.
◊
The gas supply piping, gas shut-off valve, and the electrical outlet
must be placed so they do not interfere with the cooktop when it is
installed.
◊
If installing another appliance in the cabinet below, allow for the
routing of gas and power behind it.
DTCT365G
36 in (91.4 cm)
42 in (106.7 cm)
DTCT466G
46 in (121.9 cm)
54 in (137.2 cm)
All tolerances: +1/16” -0” unless otherwise noted.
The installation must allow for the following:
A
Combustible overhead
cabinets
13 in max.
(33.0 cm)
Combustible
surface to rear
See cutout
dimensions
15 in min.1, 3
(45.7 cm)
3
2
30 in min.1,
(76.2 cm)
◊
That the 40-inch (101.6 cm) power cord must be able to reach
an electrical outlet, and that outlet must be accessable when the
cooktop is in place.
◊
Access to the underside of the cooktop for service and inspection
purposes.
◊
Clearance inside the cabinet to allow for proper hold- down bracket
installation.
◊
For access to the underneath of the cooktop, a fixed shelf should
not be installed below the cooktop.
If installing the cooktop with a downdraft, use only the approved Dacor
model numbers specified below:
7 1/2 in (19.1 cm) min. to
combustible side wall,
above counter (on both sides)
Measured from top of cooktop grate.
2
If installing with an overhead vent hood, also check hood
specifications for minimum required clearances.
3
Not applicable for cabinets more than a horizontal distance of 6 in.
(15.2 cm) from edge of cooktop. Allow 7 1/2 in (19.1 cm) from edge
of cutout.
All specifications subject to change without notice.
Access to the gas shut-off valve and regulator after the unit is
installed.
Downdraft Compatibility
1 7/8 in min.
(4.8 cm)
1
◊
Cooktop Models:
Use with These Approved Downdraft
Models:
DTCT304G
ERV3015, PRV30, RV30
DTCT365G
ERV3615, PRV36, RV36
DTCT466G
PRV46, RV46
www.dacor.com
Phone: (800) 793-0093
4.24
DTCT304, DTCT365, DTCT466
Revised 11/05/15 Page 5/5
Document # PG04-008
PLANNING
GUIDE
Distinctive 30”, 36” and 46” Wide
Drop-in Gas Cooktops
®
Square
Cutout
Side
wall
Rear
wall
Vertical
combustible
surface
4 1/4 in (10.8 cm) min.
between mounting surface
and combustibles below
cooktop chassis
C
7 1/2 in (19.1 cm) min.
to combustible
side wall above
countertop
(on both sides of cooktop)
E Rear
wall
D
1 7/8 in min.
(4.8 cm)
u
mb
Co
s
all
ew
bl
sti
)
ide
s
nd
ra
a
(re
4 1/4 in (10.8 cm) min.
between mounting surface
and combustibles below
cooktop chassis
H
F
G
C
Combustible side
wall
H
7 1/2 in (19.1 cm) min.
to combustible
side wall above
countertop
(both sides)
E
D
Notched
Cutout
* Total cutout depth accommodates both the cooktop and downdraft.
1 7/8 in min.
(4.8 cm)
CUTOUT TYPE AND DIMENSIONS
Cutout Shape
C Min.
D
E
F
G
H
DTCT304G without
downdraft
Configuration
Square
2 7/8 in
(7.3 cm)
19 3/4 in
(50.2 cm)
27 3/4 in
(68.6 cm)
NA
NA
NA
DTCT304G with
ERV3015 and PRV30
Square
3/8 in
(1.0 cm)
22 1/2 in
(57.2 cm)*
27 3/4 in
(68.6 cm)
NA
NA
NA
DTCT304G with RV30
Square
5/8 in
(1.6 cm)
22 1/4 in
56.5 cm)*
27 3/4 in
(68.6 cm)
NA
NA
NA
DTCT365G without
downdraft
Square
2 3/8 in
(6.0 cm)
19 3/4 in
(50.2 cm)
33 5/8 in
(85.4 cm)
NA
NA
NA
DTCT365G with
ERV3615 and PRV36
Square
3/8 in
(1.0 cm)
22 1/2 in
(57.2 cm)*
33 5/8 in
(85.4 cm)
NA
NA
NA
DTCT365G with RV36
Square
5/8 in
(1.6 cm)
22 1/4 in
(56.5 cm)*
33 5/8 in
(85.4 cm)
NA
NA
NA
DTCT466G without
downdraft
Square
2 7/8 in
(7.3 cm)
19 3/4 in
(50.2 cm)
44 1/2 in
(113.03 cm)
NA
NA
NA
DTCT466G with PRV46
Notched
3/8 in
(1.0 cm)
22 1/2 in
(57.2 cm)*
44 1/2 in
(113.03 cm)
43 1/2 in
(110.5 cm)
5/8 in
(1.6 cm)
2 5/8 in **
(6.7 cm)
DTCT466G with RV46
Notched
5/8 in
(1.6 cm)
22 1/4 in
(56.5 cm)*
44 1/2 in
(113.03 cm)
43 1/2 in
(110.5 cm)
5/8 in
(1.6 cm)
2 3/8 in **
(6.0 cm)
All specifications subject to change without notice.
www.dacor.com
Phone: (800) 793-0093
4.25
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising