SERVICE DATA SHEET
PERFORMANCE DATA
NO LOAD & NO DOOR OPENINGS AT MID-POINT
CONTROL SETTING
Type A with Run/Start Capacitor
SERVICE MODE
808662202
ICE & WATER - AUTOMATIC DEFROST
SIDE BY SIDE MODELS - R134a
65ºF (18ºC) Ambient
90ºF (32ºC) Ambient
32 to 40%
55 to 65%
0º to 4ºF (-18º to -16ºC)
-1º to 3ºF (-18º to -16ºC)
Refrigerator Temperature
34º to 39ºF (1º to 4ºC)
34º to 39ºF (1º to 4ºC)
Low Side Pressure (cut-in)
5 to 12 psig (34 to 83 kPa)
5 to 12 psig (34 to 83 kPa)
The information provided herein is designed to assist qualified repair personnel only. Untrained persons
should not attempt to make repairs due to the possibility of electrical shock. Disconnect power cord
before servicing this appliance.
-2 to 2 psig (-14 to 14 kPa)
IMPORTANT
Operating Time
Freezer Temperature
Low Side Pressure (cut-out)
High Side Pressure
(Last 1/3 of cycle)
-2 to 2 psig (-14 to 14 kPa)
90 to 115 psig
(621 to 793 kPa)
130 to 155 psig
(896 to 1069 kPa)
Wattage (Last 1/3 of cycle)
120 to 150
130 to 160
Amps (Running)
1.2 to 1.5
1.2 to 1.5
115 vac (127 vac max)
115 vac (127 vac max)
Base Voltage
Refrigerant Change
IMPORTANT SAFETY NOTE
If any green grounding wires are removed during servicing, they must be returned to their original
position and properly secured.
CAUTION
4.25 oz. (121 g)
SPECIAL MODES
Thermostat
Cabinet Size
23’ & 26’
Cut-In
Cut-Out
Watts
Ohms
25ºF (-4ºC)
47ºF (8ºC)
450
30
FZ
Manual
Defrost
d
FZ
Amps
3.1 (Energy Star - Some models)
1100 CW Opposite Shaft
.03 Running
8.0
2550 CW Opposite Shaft
.07 Running
Showroom
F
Service
ICE MAKER SPECIFICATIONS
Electrical
Thermostat
115 vac (127 vac max)
60 Hertz
Opens at 48ºF (9ºC)
Closes at 15ºF (-9ºC)
Heater Wattage
77
No
Display
Evaporator
Fan
FZ
Thermistor
FF
Thermistor
---
Display is blank when selecting test.
A
Displays last 4 digits of software variant; record sequence.
B
Displays last 4 digits of control and housing assembly part number; record sequence.
C
Displays software test number.
---
Display is blank when selecting test.
A
Turns on evaporator fan, displays “E”.
B
Turns off evaporator fan, displays “_”.
---
Display is blank when selecting test.
A
Flashes “1” if good, “SH” if shorted, and “OP” if open.
B
Displays current FZ temperature. If technician puts hand around thermistor, the
temperature will rise.
---
Display is blank when selecting test.
A
Flashes “1” if good, “SH” if shorted, and “OP” if open.
B
Displays current FF temperature. If technician puts hand around thermistor, the
temperature will rise.
OP
---
Open FZ Thermistor
---
OP
Open FF Thermistor
---
Display is blank when selecting test.
SH
---
Shorted FZ Thermistor
A
Damper opens, displays “0”. If there is a switch or motor error, flashes “4”.
---
SH
Shorted FF Thermistor
B
Damper closes, displays “_”. If there is a switch or motor error, flashes “4”.
HI
---
FZ Temp. above 26ºF
---
HI
FF Temp. above 55ºF
C
If A or B did not display a “4” this test will display “_” and the motor will not run.
If “4” was displayed in test A or B this test displays “E”, and runs the motor
continuously. If motor movement is not heard, there is a problem with the
motor or motor circuit.
If motor is running, there is a problem with the damper switch or damper
switch circuit.
---
Display is blank when selecting test.
A
Turns on defrost heater, displays “d” if DTT is closed and “_” if DTT is open.
Note: Evaporator fan will be on for the duration of this test to aide in evaluation of the damper.
5
6
7
Damper
Motor
Defrost
Compressor
and
Condenser
Fan
B
Turns off defrost heater, displays “_”.
---
Display is blank when selecting test.
A
Turns on compressor and condenser fan, displays “C”.
B
Turns off compressor and condenser fan, displays “_” .
Once compressor is turned off it cannot be turned on for 7 minutes. 7 minute
countdown is displayed in test A.
---
Display is blank when selecting test.
A
Turns on all segements of FF display, FZ display, and all LEDs.
---
Display is blank when selecting test.
A
Displays maximum of 8 errors from the last 10 days. If there are no errors,
displays “-” on single digit and “- -” on dual digit.
B
Flashes bottom and middle segments. Press and hold FF DOWN to erase history.
kOHMS
°F
kOHMS
°F
kOHMS
°F
kOHMS
11.75
11
60.48
32
32.51
53
18.27
Ground
-9
11.41
12
58.52
33
31.53
54
17.84
Water Valve
-8
11.01
13
56.94
34
30.74
55
17.34
Line
-7
10.69
14
55.11
35
29.82
56
16.93
-6
10.32
15
53.34
36
29.07
57
16.39
-5
10.02
16
51.91
37
28.21
58
16.08
-4
96.79
17
50.25
38
27.51
59
15.64
-3
93.47
18
48.92
39
26.70
60
15.21
-2
90.80
19
47.37
40
26.04
61
14.86
Error
Error History Log Codes
-1
87.71
20
46.12
41
25.28
62
14.46
3
Open FZ Thermistor
0
85.22
21
44.67
42
24.54
63
14.13
4
Shorted FZ Thermistor
1
82.34
22
43.50
43
23.94
64
13.74
5
Damper did not move from close to open position in allotted time
2
80.02
23
42.14
44
23.25
65
13.43
6
Damper did not move from open to close position in allotted time
3
77.34
24
40.83
45
22.67
66
13.07
4
75.18
25
39.77
46
22.03
67
12.78
15
DTT Connector Out or Shorted DTT
5
72.68
26
38.55
47
21.50
68
12.44
23
User Interface Key Stuck Down
6
70.27
27
37.56
48
20.89
69
12.10
24
Open FF Thermistor
7
68.33
28
36.41
49
20.39
70
11.84
25
Shorted FF Thermistor
8
66.08
29
35.48
50
19.81
71
11.52
26
FZ High Temperature Alarm
9
64.27
30
34.40
51
19.25
72
11.27
27
FF High Temperature Alarm
10
62.17
31
33.53
52
18.80
73
10.97
33
Heater, Heater Circuit, Heater Wiring, or DTT Problem
2
Yellow
Water Fill Volume: The water fill adjustment
screw will change the fill time. One full turn is
equal to 20cc (.68 oz.). The correct fill is 102 to
130cc (3.4 to 4.3 oz.). When a water valve is
replaced, the fill volume must be checked.
Software
Sub Test Test Description
°F
Green/Yellow
Test Cycling: Remove cover by inserting screwdriver in notch at bottom and prying cover from
housing. Use screwdriver to rotate motor gear
counterclockwise until holding switch circuit is
completed. All components of ice maker should
function to complete the cycle.
3
Test Name
-10
1
ICE MAKER INFORMATION
1
4
FOR FRESH FOOD AND FREEZER THERMISTORS
Connect to:
Lt. Blue
Test
TEMPERATURE/RESISTANCE CHART
Wire Color
Black
FF
Solid
Press and hold FRZ UP; then press
FRZ DOWN 3 times within 6 sec.
Press and hold FRZ UP key for 5
sec. to deactivate. Automatically deactivates after 5 minutes of inactivity.
165
Wire Number
4
Press and hold FF UP; then press
FF DOWN 3 times within 5 sec.
Displays will flash “0” “0”. Press
FRZ UP within 5 sec. Requires
Power-on-Reset to deactivate.
77
ICE MAKER PLUG CONNECTIONS
3
Press FRZ UP or DOWN to change test.
Press FF UP or DOWN to change between sub tests.
View UI display for results of tests.
Listen for operating sounds; feel for heat or air flow as appropriate to determine results of tests.
Flashing
Press and hold FRZ UP; then press
FF DOWN key 5 times within 5 sec.
Input is recognized when FRZ UP is
released. Same to deactivate.
CONDENSER FAN MOTOR
RPM
•
•
•
•
Display
FF
Electronic Timer - (ADC) Defrost 24 minutes every 6 to 72 hours of compressor run time.
Watts
Press and hold FRZ UP for 5 seconds. Diagnostic mode will automatically deactivate after 5
minutes of inactivity.
ERROR CODES
Display
Heater
Deactivate:
2
All electrical parts and wiring must be shielded from torch flame. DO NOT allow torch to
touch insulation; it will char at 200°F and flash ignite (burn) at 500°F. Excessive heat will
distort the plastic liner.
DEFROST SPECIFICATIONS
Activate:
Press and hold FRZ UP then press FRZ DOWN 3 times within 6 sec. Input is recognized
once FRZ UP is released. Press FRZ UP or DOWN to change test.
Neutral
8
9
Display
Error
History Log
TEST 9 ERROR CODES
A02644901 Wiring Diagram
ELECTRO-MECHANICAL DISPENSER
PTC STARTER WITH RUN CAPACITOR
WATER DISP.
RED/BLK (120 VAC)
SWITCH
NO
NC
NC
PURPLE (AUGER)
NEUTRAL
LINE
1
J6
DISPENSER HOUSING HEATER
J2
1
BLUE/WHT (LINE)
BLK
WHT/GRY
LT. BLUE (AUGER)
J3
TAN
TAN/BLK
WHT
RED
RED/BLK (NEUTRAL)
TAN (WATER VALVE)
6
BLACK
WHT/GRY
WATER DISP. SWITCH
TAN
NC
TAN/BLK
NO
WHT
ICE DISP. SWITCH
COMM
NO
S
2
COMM
NC
*
RED
M
*
L
M
1
PTC
STARTER
COMP.
MOTOR
OVERLOAD
S
5
C
DISPENSER
LED
3
6
RUN
TAN (WATER VALVE)
1
PURPLE (CUBE)
START
RED
NO
GRN/YEL
COMM
COMM
RUN CAPACITOR
ICE DISP. SWITCH
LT. BLU
ICE & WATER CONTROL BOARD
CAPACITOR IS ONLY USED WITH
SOME P.T.C. MODELS.
1
1
(LINE)
S2
NO
NC
CUBE
S3
S4
S3
NO
NC
NC
NO
LIGHT
CRUSH
S1
NC
NO
(NEUTRAL)
RESET
NO
NC
LOCKOUT
DAMPER ASSEMBLY
EVAP. FAN
DEFROST
THERM.
GAMMA
CONTROL
RED
LT. BLU
TAN
BLU/WHT
PURPLE
SEE
COMPRESSOR
WIRING
BROWN
WATER
VALVE
NON-RIBBED
J1-8
J1-10
J1-3
J6-2
SEE
DISPENSER ASS'Y
BROWN
YEL/BLK
2
GRN/YEL
3
RED/WHT 4 EVAP FAN
RED/WHT
ORG/WHT
4
RED/BLK 5 DAMPER
5
BLACK
6
ORN/WHT 6FAST ICE/FZ
BLUE
7
RED
8
LT. BLU
9
BLACK
MAIN WATER VALVE
WIRING
2 OPEN
3 LINE
DISPENSER WATER VALVE
ACTUATOR,ICE DOOR
DEFROST
THERM
YEL/BLK
8 FF DOOR
BLUE
7
BROWN
MOTOR,AUGER
9 HEATER
10 FZ DOOR
YEL/RED
TAN
DIODE
DIODE
COMPRESSOR
CONTROL
RELAY
I/M WATER VALVE
M
AIR
FILTER
1 NEUTRAL
1
YEL/RED
YEL/BLK
BLACK
LIGHT SWITCH
(REFRIG)
YELLOW
LINE
RED
RED
DEFROST
THERM.
SPLICE
LT. BLU
BLACK
BROWN
BLU/WHT
DEFROST HEATER
GRN/YEL
YELLOW
RED/WHT
YEL/RED
PURPLE
AUGER
ASS'Y
FRZ
LIGHT
GRN/YEL
LT.BLUE
LT. BLU
RL1
GREY
LT. BLUE
BLUE
FRZR.
FAN
J6
ICE MAKER
J10
1
2
3
4
HEATER,ICE DOOR
FF NTC
MID LEVEL LIGHT
FZ NTC
CRISPER LIGHT
PURP/WHITE
GRN/YEL
RED/BLK
DRAIN
TROUGH
YELLOW
WATER
DISPENSER
VALVE
J7
J1
LT.BLUE
BLACK
LT. BLU
SEE
COMPRESSOR
WIRING
RED
AUTO
ICEMAKER
LT.BLUE
LT.BLUE
YEL/BLK
LIGHT SWITCH
(FRZR)
J1-7
RED
FF CONTROL
HOUSING
LIGHT
1
2
RIBBED
COND. FAN
J1-9
J1-1
GAMMA CONTROL
ALL WIRE CONNECTIONS
MARKED BY "O" SYMBOL.
J1-4
J10-3
J10-4
J1-5
FRZ THERMISTOR
BLK
YEL/BLK
LT. BLU
FRZR DOOR
GROUND
CABINET
GROUND
GREEN
I/M
WATER
VALVE
FF THERMISTOR
RL1
COMPRESSOR
GROUND
DIODES TO BE
POLARIZED AS SHOWN.
J7
J10-1
J10-2
COND. FAN
COMP
MID LEVEL
LIGHT
SEE
DISPENSER ASS'Y
WIRING
CRISP.
LIGHT
AIR FILTER FAN M
J6-1
COIL HEATER
FRZR. LIGHT
DAMPER
MOTOR
SW
FREEZER LIGHT /
SAFETY SWITCH
REFRIG. LIGHT
YEL/RED
REFRIG. LIGHT SWITCH
B
GREEN