Miele | 28669055USA | Operating/Installation Instructions | Miele 28669055USA Operating/Installation Instructions

Operating and Installation Instructions
Ventilation Hood
To prevent accidents and damage to the appliance, you must read
these instructions before installing the appliance and using it for the first
time.
en-US
M.-Nr. 09 805 980
Contents
IMPORTANT SAFETY INSTRUCTIONS ................................................................ 4
Caring for the environment ................................................................................ 13
Description of functions ..................................................................................... 14
Con@ctivity 2.0 function........................................................................................ 15
Guide to the appliance ........................................................................................ 16
Operation (Automatic mode) ..............................................................................
Cooking with Con@ctivity 2.0 (Automatic mode) ..................................................
Temporarily exiting Automatic mode .....................................................................
Resuming Automatic mode...................................................................................
18
18
20
20
Operation (Manual mode) ...................................................................................
Cooking without Con@ctivity 2.0 (Manual mode) .................................................
Turning on the fan..................................................................................................
Selecting the power level ......................................................................................
Selecting the delayed shut down time ..................................................................
Turning off the fan .................................................................................................
Turning overhead lighting on/off............................................................................
Power management ..............................................................................................
21
21
21
21
21
21
22
22
Operation (Automatic and Manual modes) .......................................................
Filter saturation indicator.......................................................................................
Adjusting the filter saturation indicator for the grease filter..............................
Activating/changing the OdorFree Charcoal Filter operating hours counter....
Checking the filter saturation indicator.............................................................
Sensor button signal tone .....................................................................................
23
23
23
24
24
25
Cleaning and care ...............................................................................................
Stainless steel housing..........................................................................................
Special instructions for glass surfaces.............................................................
Grease filters .........................................................................................................
OdorFree Charcoal Filter .......................................................................................
Resetting the operating hours counter for the OdorFree Charcoal Filter .........
26
26
27
27
29
30
Installation............................................................................................................
Before installation..................................................................................................
Installation parts ....................................................................................................
Appliance dimensions ...........................................................................................
Distance between cooktop and ventilation hood (S).............................................
Installation recommendations ...............................................................................
Structural support .................................................................................................
Removing the protective film.................................................................................
31
31
31
32
33
34
34
34
2
Contents
Exhaust duct ........................................................................................................ 46
Condensate trap.................................................................................................... 47
Electrical connection .......................................................................................... 48
Grounding Instructions.......................................................................................... 48
Activating Con@ctivity 2.0 ..................................................................................
Installation of the Con@ctivity 2.0 stick.................................................................
Activating the Con@ctivity 2.0 function.................................................................
Activating the ventilation hood .........................................................................
Activating the cooktop .....................................................................................
Activation failed ................................................................................................
Deactivating Con@ctivity 2.0.................................................................................
49
49
49
49
50
50
50
Service and warranty .......................................................................................... 51
Location of the data plate ..................................................................................... 51
MieleCare .............................................................................................................. 51
Technical data ..................................................................................................... 52
3
IMPORTANT SAFETY INSTRUCTIONS
READ AND SAVE THESE INSTRUCTIONS
This appliance complies with current safety requirements. Improper use of the appliance can lead to personal injury and material damage.
Read all instructions before installing or using the appliance for the
first time. Only use the appliance for its intended purpose.
Keep these operating instructions in a safe place and pass them
on to any future user.
Use
 CAUTION: For General Ventilating Use Only. Do Not Use To Exhaust Hazardous Or Explosive Materials And Vapors.
 This appliance is intended for residential use only. Use only as described in these operating instructions.
 This ventilation hood is designed for domestic use and for use in
similar residential environments.
 This ventilation hood is not intended for outdoor use.
 It must only be used to extract and clean vapors produced during
cooking. Any other use occurs at the owner's own risk.
 This appliance is suitable for installation above gas or electric
cooking surfaces.
 Persons who lack physical, sensory or mental abilities, or experience with the appliance should not use it without supervision or instruction by a responsible person.
4
IMPORTANT SAFETY INSTRUCTIONS
Children
 As with any appliance, close supervision is necessary when used
by children.
 Please supervise children in the vicinity of the hood and do not let
them play with it.
 Danger of suffocation! Ensure that any plastic wrappings, bags,
etc. are disposed of safely and kept out of the reach of children.
Technical safety
 WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK,
OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
– Use this appliance only in the manner intended by the manufacturer. If you have questions, contact Miele.
– Before servicing or cleaning the appliance, switch power off at the
service panel and lock the service disconnecting means to prevent power from being switched on accidentally. If the service
disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
 Installation, repair and maintenance work should be performed by
a Miele authorized service technician in accordance with national
and local safety regulations and the provided installation instructions. Contact Miele’s Technical Service Department for examination,
repair or adjustment. Repairs and other work by unauthorized persons could be dangerous and may void the warranty.
 A damaged ventilation hood oven can be dangerous. Always
check for visible signs of damage. Never use a damaged ventilation
hood.
5
IMPORTANT SAFETY INSTRUCTIONS
 Be certain your appliance is properly installed and grounded by a
qualified technician. To guarantee the electrical safety of this appliance, continuity must exist between the appliance and an effective
grounding system. It is imperative that this basic safety requirement
be met. If there is any doubt, have the electrical system of the house
checked by a qualified electrician.
 Reliable and safe operation of this hood can only be guaranteed if
it has been connected to the electrical supply.
 To avoid damaging the ventilation hood, make sure that the connection data (voltage and frequency) on the data plate correspond to
the building's power supply before connecting the appliance. When
in doubt, consult a qualified electrician.
 Do not use a power bar or extension cord to connect the ventilation hood to electricity. These are a fire hazard and do not guarantee
the required level of appliance safety.
 To ensure safe operation, only use the ventilation hood after it has
been properly installed.
 This ventilation hood may not be used in non-stationary locations
(e.g. on a ship).
 Adequate ventilation must be provided when the hood is operated
simultaneously with devices that burn gas or other fuels.
 Only open the housing as described in the enclosed "Installation
diagram" and in the "Cleaning and care" section of this manual. Under no circumstances should any other parts of the housing be
opened.
Tampering with electrical connections or components and mechanical parts is highly dangerous to the user and can cause operation
faults.
 Defective components should be replaced by Miele original parts
only. Only with these parts can the manufacturer guarantee the
safety of the appliance.
6
IMPORTANT SAFETY INSTRUCTIONS
 During installation, maintenance, and repair work, the ventilation
hood must be disconnected from the electrical supply. It is only
completely isolated from the electricity supply if one of the following
applies:
– The circuit breakers on the electrical service panel are tripped.
– The screw-type fuses on the electrical service panel have been
removed.
– The power cable (if present) has been unplugged from the socket
(pull the plug not the cord).
Proper use
 WARNING: TO REDUCE THE RISK OF A COOKTOP GREASE
FIRE:
– a) Never leave surface units unattended at high settings. Boilovers
cause smoking and greasy spillovers may ignite. Heat oils slowly
on low or medium settings.
– b) Always turn the hood on when cooking at a high heat.
– c) Clean the ventilation hood frequently. Grease should not be allowed to accumulate on the fan or filter.
– d) Use the proper pan size. Always use cookware appropriate for
the size of the cooking area.
 Never use an open flame beneath the ventilation hood.
To avoid the risk of fire, do not flambé or grill over an open flame.
When turned on, the ventilation hood will draw any flames into the
filter. Fat deposits may ignite.
7
IMPORTANT SAFETY INSTRUCTIONS
 WARNING: TO REDUCE THE RISK OF INJURY TO PERSONS IN
THE EVENT OF A COOKTOP GREASE FIRE, OBSERVE THE FOLLOWING*:
– a) SMOTHER FLAMES with a close fitting lid, cookie sheet, or
metal tray then turn off the burner. BE CAREFUL TO PREVENT
BURNS. If the flames do not go out immediately, EVACUATE AND
CALL THE FIRE DEPARTMENT.
– b) NEVER PICK UP A FLAMING PAN - You may be burned.
– c) DO NOT USE WATER, including wet dishcloths or towels - a violent steam explosion will result.
– d) Use a fire extinguisher ONLY if:
– 1) You have a class ABC extinguisher, and you know how to operate it.
– 2) The fire is small and contained in the area where it started.
– 3) The fire department is being called.
– 4) You can fight the fire with your back to an exit.
*Based on "Kitchen Firesafety Tips" published by NFPA.
 The ventilation hood may become damaged if exposed to excessive heat from a gas cooktop.
– When using the ventilation hood over a gas cooktop, ensure that
any burners in use are always covered by cookware. Turn burners
off when removing the cookware, even if doing so for just a short
time.
– Select cookware that is suitable for the size of the burner.
– Adjust the flame so that it never extends up the sides of the cookware.
– Avoid overheating the cookware (e.g., when cooking with a wok).
 Always turn the ventilation hood on whenever a burner is in use to
prevent damage from condensation.
8
IMPORTANT SAFETY INSTRUCTIONS
 Overheated oils and fats can ignite and set the ventilation hood on
fire.
When cooking with oils or fats, do not leave pots, pans or fryers
unattended. Never leave an electric grill unattended when grilling.
 Fat and debris deposits impair the proper functioning of the ventilation hood.
To ensure that cooking vapors are properly cleaned, never use the
ventilation hood without the grease filters in place.
 There is a risk of fire if cleaning is not completed according to the
instructions in this manual.
 Please note that the heat rising from the stovetop during cooking
can cause the ventilation hood to become very hot.
Do not touch the housing or the grease filters until the ventilation
hood has cooled down.
9
IMPORTANT SAFETY INSTRUCTIONS
Proper installation
 WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK,
OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
– a) Installation work and electrical wiring must be done by qualified
person(s) in accordance with all applicable codes and standards,
including fire-rated construction.
– b) Sufficient air is needed for combustion and exhausting of gases
through the flue (chimney of fuel burning equipment to prevent
back drafting. Follow the heating equipment manufacturer’s
guideline and safety standards such as those published by the
National Fire Protection Association (NFPA) and the American Society for Heating, Refrigeration and Air Conditioning Engineers
(ASHRAE), and the local code authorities.
– c) When cutting or drilling into the wall or ceiling, do not damage
electrical wiring and other hidden utilities.
– d) Ducted hoods must always be vented to the outdoors.
– e) Do not use this hood with any solid-state speed control device.
 To determine whether a ventilation hood may be operated above
your cooking appliance, please refer to the information provided by
the appliance's manufacturer.
 Safety regulations prohibit the installation of a ventilation hood
above solid fuel stoves.
 Insufficient distance between the cooking appliance and the ventilation hood can result in damage to the hood.
The minimum safety distances between the appliance and the bottom of the ventilation hood specified in the "Installation" section
must be maintained, unless the appliance's manufacturer has indicated that a greater distance is required.
If more than one cooking appliance is used beneath the ventilation
hood, and if different minimum safety distances apply for these appliances, you should use the greater distance.
10
IMPORTANT SAFETY INSTRUCTIONS
 Be sure to observe the information contained in the "Installation"
section when mounting the ventilation hood.
 Metal parts can have sharp edges which may cause injury.
Wear gloves to protect your hands from being cut.
 When installing the exhaust duct, only use pipes or tubes made of
non-flammable material. These can be obtained from your Miele
dealer or from Miele Technical Service.
 Exhaust air should not be vented into a chimney or vent flue which
is otherwise in use and should not be channeled into ducting which
ventilates rooms with fuel-burning installations.
 If exhaust air is to be extracted into a chimney or vent flue no
longer used for other purposes, be sure to comply with all applicable
regulations.
 WARNING: TO REDUCE THE RISK OF FIRE USE ONLY METAL
DUCTWORK.
Cleaning and care
 Never use a steam cleaner to clean the ventilation hood.
The steam can reach the electrical components and cause a short
circuit.
Accessories
 Use only genuine original Miele parts. If parts or accessories from
other manufacturers are used, the warranty will become void.
11
IMPORTANT SAFETY INSTRUCTIONS
FCC Declaration of Conformity
 These devices comply with FCC Rules Part 15. This equipment
has been tested and found to be in compliance with the limits for a
Class B digital device, pursuant to Part 15 of the FCC Rules of Operation and is subject to the following conditions:
These devices may not cause harmful interference.
These devices must accept any interference received, including interference that may cause undesired operation.
FCC Radiation Exposure Statement
 This equipment complies with FCC radiation exposure limits set
forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 8" (20 cm) between the
radiator and your body.
Industry Canada Statement
 This digital apparatus does not exceed the Class B limits for Radio Noise Emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications.
Complies with Canadian ICES-003 Class B specifications.
12
Caring for the environment
Disposal of the packing material
The cardboard box and packing materials protect the appliance during shipping. They have been designed to be
biodegradable and recyclable.
Ensure that any plastic wrappings,
bags, etc. are disposed of safely and
kept out of the reach of children. Danger of suffocation!
Disposal of your old appliance
Do not dispose of this appliance with
your household waste.
Old appliances may contain materials
that can be recycled. Please contact
your local recycling authority about the
possibility of recycling these materials.
Before discarding an old appliance ensure that it presents no danger to children while being stored for disposal.
Unplug it from the outlet, cut off its
power cord and remove any doors to
prevent hazards.
13
Description of functions
The following functions are available on
your ventilation hood, depending on the
model:
Vented mode
The air is drawn in and cleaned by the
grease filters and directed outside.
Non-return flap
A non-return flap in the ducting prevents the exchange of inside and outside air from occurring when the ventilation hood is not in use.
The flap is closed when the ventilation
hood is turned off.
When the ventilation hood is turned on,
the non-return flap opens so that the
exhaust air can be transported outside
without any obstruction.
A non-return flap has been provided
with the hood in case your ducting does
not have one. It is inserted into the outlet duct collar of the fan.
14
Recirculation mode
The recirculation mode requires a recirculation kit and OdorFree Charcoal Filter (available as optional accessories,
see "Technical Data" for more information)
The air is drawn in and first cleaned by
the grease filters and then by an OdorFree Charcoal Filter. The cleaned air is
then recirculated back into the kitchen.
Description of functions
Con@ctivity 2.0 function
Automatic control
This hood features a communication
function which enables the automatic
control of the hood based on the operational status of a Miele induction cooktop.
The cooktop transmits information
about its operational status to the hood
using a radio signal.
– When a burner is turned on, the
cooktop lighting on the hood turns on
automatically. After a brief delay, the
ventilation hood fan also comes on.
– During cooking, the hood automatically selects the fan level based on
the number of burners in operation
and their power levels.
– Once you have turned off the cooktop, the fan and the lighting will turn
off automatically after a predetermined delay.
Detailed information about this function
can be found under "Operation."
To enable the communication function,
the cooktop must be equipped with the
corresponding Con@ctivity 2.0 stick .
Please refer to the installation instructions for the Con@ctivity 2.0 stick to determine whether connection to your
cooktop is possible.
There must be radio contact between
the cooktop and the hood for you to be
able to use the Con@ctivity 2.0 function
(see "Activating Con@ctivity 2.0").
15
Guide to the appliance
16
Guide to the appliance
a Chimney extension
b Chimney
c Canopy
d Control panel
The symbols act as sensor-controlled buttons. To select a function, tap the button. An audible tone sounds briefly to confirm selection.
e Grease filter
f Spacer frame
The spacer frame creates a shadow gap between the chimney and the ceiling.
The hood can be installed with or without the spacer frame.
g Recirculation vent
(only for recirculation mode)
h Overhead lighting
i OdorFree Charcoal Filter
Optional accessory for recirculation mode
j Turns the fan on and off
k Overhead light button
l Fan power selection
m Delayed shut-down button
n Filter saturation indicator for the grease filters
o Filter saturation indicator for the OdorFree Charcoal Filter
17
Operation (Automatic mode)
When Con@ctivity 2.0 is active, the
hood always operates in Automatic
mode (see "Activating Con@ctivity
2.0").
See "Cooking without Con@ctivity 2.0"
for information on manually operating
the hood.
Cooking with Con@ctivity 2.0
(Automatic mode)
 Turn on a burner to the desired power
setting.
Overhead cooktop lighting.
After a few seconds, the fan will come
on, briefly operating at power level 2
before immediately switching to level 1.
The hood selects the fan level automatically during cooking.
This level is determined by the total output of the cooktop, i.e. the number of
burners in operation and the power settings selected.
 If you select a higher power setting
on the cooktop or switch on multiple
burners, the hood will switch to a
higher fan level.
 If you select a lower power setting on
the cooktop or turn off a burner, the
hood will accordingly switch to a
lower fan level.
Examples for fan levels 1 to 4
18
Reaction time
Changing the power setting on the
cooktop does not lead to an immediate
increase or decrease in cooking vapors.
For this reason, the hood reacts with a
slight delay.
Delays can also result from the fact that
the cooktop transmits the information to
the hood in intervals.
The reaction time can vary from a few
seconds to a couple of minutes.
Operation (Automatic mode)
Cooking process
Deactivation
 If, for example, you switch on a
burner at the highest power setting to
heat cookware in preparation for
searing and then reduce the power
level after approx. 60 to 90 seconds,
a cooking process is recognized.
 Turn off all burners.
The hood turns on automatically and,
after the cooktop power level has been
reduced, switches back to fan level 3,
where it remains for approx. 5 minutes.
After this, the fan level is once again determined by the Con@ctivity function.
 You can also manually select a different fan level before then.
Over the next few minutes, the ventilation hood fan setting will decrease one
level at a time until the hood eventually
turns off.
This helps to neutralize any lingering vapors and odors in the air.
– From the intensive setting, the fan immediately switches to level 3.
– If the fan is operating at level 3, it will
switch to level 2 after approx. 1
minute.
– From level 2, the fan switches to level
1 after 2 minutes.
– After 2 minutes at level 1, the fan automatically turns off.
– After another 30 seconds, the overhead cooktop lighting turns off.
The cooking process is now finished.
19
Operation (Automatic mode)
Temporarily exiting Automatic
mode
To temporarily exit the Automatic mode
when cooking:
 Manually select a different fan level,
or
 Manually turn the hood off, or
 Activate the Delayed shut down function  on the ventilation hood. The
fan turns off after the delay time selected, and the lighting will remain on.
The ventilation hood functions can now
be operated manually (see "Cooking
without Con@ctivity 2.0").
Resuming Automatic mode
The ventilation hood resumes Automatic mode:
 If the ventilation hood has not been
used for a period of approx. 5 minutes after the manual selection of a
fan level, or
 If the manually selected fan level
once again matches the automatic
setting, or
 If the ventilation hood fan and the
cooktop have been turned off for at
least 30 seconds.
Automatic mode will resume the next
time the cooktop is turned on.
 If you wish to manually operate the
ventilation hood for a complete cooking process, turn on the ventilation
hood fan before turning on the cooktop.
If the ventilation hood and the cooktop have been turned off for at least
30 seconds after you have finished
cooking, Automatic mode will resume
the next time the cooktop is turned
on.
20
Operation (Manual mode)
Cooking without Con@ctivity
2.0 (Manual mode)
Selecting the delayed shut
down time
The hood can be operated manually if:
It is a good idea to let the fan run for a
few more minutes after cooking in order
to neutralize any lingering vapors and
odors in the air.
With the delayed shut down function, it
is possible to have the fan automatically
shut off after a predetermined period of
time.
– The Con@ctivity 2.0 function is not
activated.
– You have temporarily deactivated the
Con@ctivity 2.0 function (see "Temporarily exiting Automatic mode").
Turning on the fan
 Tap the On/Off button .
The fan switches to level 2.
Selecting the power level
Power levels 1 to 3 can be used for light
to heavy cooking vapors and odors.
 After you have finished cooking, tap
the delayed shut down button .
– Once: fan switches off after 5 minutes (5  lights up).
– Twice: fan switches off after 15 minutes (15  lights up).
– If you press the delayed shut down
button  again, the fan remains
turned on (5 15 goes out).
For strong vapors and odors that are
temporarily produced when cooking,
e.g., during searing, select the IS intensive level.
Turning off the fan
 Select the power level required by
tapping a button from 1 to IS.
 Press the On/Off button  to turn the
fan off.
Reducing power of the intensive setting
If power management is activated (default setting), the fan automatically
switches back to level 3 after 5 minutes.
21
Operation (Manual mode)
Turning overhead lighting on/
off
 Tap 1 to turn off the power management.
The overhead lighting can be turned on
and off separately from the fan.
The 1 and IS indicators will flash.
 Tap the lighting button .
The 1 and IS indicators are constantly
lit.
Power management
The ventilation hood features a power
management system to help save energy. The fan power level is reduced
and the lighting is turned off automatically.
– If the intensive setting is selected, the
fan automatically switches to level 3
after 5 minutes.
– If the fan is set to level 3, 2 or 1, it
switches back one fan setting after 2
hours and then in 30-minute intervals
until the fan eventually switches off.
– If the overhead lighting is on, it automatically turns off after 12 hours.
Turning power management on/off
 Turn off the fan and the lighting.
 Press the delayed shut down button
 for approx. 10 seconds until 1
lights up in the fan power display.
 Next, tap the following buttons in
succession:
– The lighting button ,
– Followed by the 1 button and then
– The lighting button  again.
If power management is turned on, the
1 and IS indicators will be continuously
lit.
If it is switched off, 1 and IS will flash.
22
 Touch IS to turn it on.
 Confirm the setting by pressing the
delayed shut down button .
All the indicator lights will go out.
If the setting is not confirmed within 4
minutes, the hood automatically reverts
to the old setting.
Operation (Automatic and Manual modes)
Filter saturation indicator
The number of hours the hood has
been in operation is stored in appliance
memory.
The filter saturation indicators show
when the filters need to be cleaned or
changed by lighting up the grease filter
symbol  or OdorFree Charcoal Filter
symbol . Additional information on
cleaning and changing the filters and
resetting the filter saturation counters
can be found under "Cleaning and
care."
Adjusting the filter saturation indicator for the grease filter
You can set the filter saturation indicator to suit your cooking habits.
The indicators 1 to IS show the current
time setting:
Indicator 1 .............................. 20 hours
Indicator 2 ............................... 30 hours
Indicator 3 ............................... 40 hours
Indicator IS .............................. 50 hours
 Tap the relevant button to select the
time required.
 Confirm your choice by touching the
grease filter button .
All the indicator lights will go out.
If the setting is not confirmed within 4
minutes, the hood automatically reverts
to the old setting.
The factory default setting is a cleaning
interval of 30 hours.
– Select a shorter time (20 hours) if you
often fry foods.
– We also recommend a shorter cleaning interval if you only cook occasionally. This will prevent grease
buildup from hardening and making
cleaning more difficult.
– Select a longer cleaning interval of 40
or 50 hours if you use very little fat
when cooking.
 Press the On/Off button  to turn off
the fan.
 Tap the delayed shut down button 
and the grease filter button  at the
same time.
The grease filter symbol  and one of
the fan power level indicators will flash.
23
Operation (Automatic and Manual modes)
Activating/changing the OdorFree
Charcoal Filter operating hours
counter
The OdorFree Charcoal Filter is required
for extraction mode.
The operating hours counter for the
OdorFree Charcoal Filter requires onetime activation and must be set to
match your cooking habits.
 Press the On/Off button  to turn the
fan off.
 Tap the delayed shut-down button 
and the OdorFree Charcoal Filter button  at the same time.
The OdorFree Charcoal Filter symbol 
and one of the fan setting indicators will
flash.
The indicators 1 to IS show the current
time setting:
Indicator 1 ............................ 120 hours
Indicator 2 ............................. 180 hours
Indicator 3 ............................ 240 hours
Indicator IS ......................... deactivated
 Tap the relevant button to select the
time required.
 Confirm your choice by tapping the
OdorFree Charcoal Filter button .
All the indicator lights go out.
If the setting is not confirmed within 4
minutes, the old setting is retained.
24
Checking the filter saturation indicator
Before the set operating time has run
out, you can check what percentage of
the time has elapsed.
 Press the On/Off button  to turn the
fan on.
 Press and hold the grease filter button  or the OdorFree Charcoal Filter
button .
One or more of the power level indicators will flash.
The number of flashing indicators
shows the elapsed operating hours as a
percentage.
Indicator 1 .................................... 25%
Indicators 1 and 2 ......................... 50%
Indicators 1 to 3 ........................... 75%
Indicators 1 to IS ........................ 100%
The elapsed operating hours remain
stored in the memory when the hood
is turned off or if power to the appliance is lost.
Operation (Automatic and Manual modes)
Sensor button signal tone
Whenever you select a feature with the
sensor buttons, you will hear a brief signal tone.
You can deactivate this signal tone if
you prefer.
 Press the On/Off button  to turn the
fan off.
 Tap the IS and the grease filter 
buttons at the same time for approx.
5 seconds until a short signal tone is
heard.
The signal tone is now turned off for all
functions.
 To reactivate the signal tone, follow
the same steps.
If the hood is disconnected from the
power supply, or after a power interruption, the beep is automatically reactivated, regardless of the previous
settings.
25
Cleaning and care
WARNING: TO REDUCE THE RISK
OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE
FOLLOWING:
 Before cleaning or servicing the
hood, disconnect it from the power
supply, see "IMPORTANT SAFETY
INSTRUCTIONS".
Stainless steel housing
General information
The surfaces and control buttons are
susceptible to scratching and chipping.
Observe the following cleaning instructions.
 Clean all surfaces and control buttons
using warm water and liquid dish
soap. Apply with a sponge cloth.
Make sure that no water gets into the
interior of the hood.
Only use a damp cloth to clean the
hood, especially in the control panel
area.
 After cleaning, dry the surfaces with a
soft cloth.
Avoid the following:
– Cleaners containing soda, acid or
chloride, or cleaners containing solvents
– Abrasive sponges, e.g. pot scourers
or sponges which have been previously used with abrasive cleaning
agents.
26
Special instructions for stainless
steel surfaces
(does not apply to control buttons)
 Stainless steel surfaces can also be
cleaned using a non-abrasive stainless steel cleaner, available from
Miele.
 To prevent the surfaces from quickly
becoming dirty again, we recommend
treating them with a stainless steel
care conditioner.
Apply sparingly over the entire area
using a soft cloth.
Special instructions for RAL color finish housing
(special order)
 Observe the general cleaning instructions contained in this chapter.
Minor scratches on the surface are inevitable when cleaning the housing.
Depending on the lighting in the
kitchen, this may negatively affect the
appliance's appearance.
Cleaning and care
Important for the controls
Do not leave dirt and debris on the
buttons for any length of time.
Otherwise they may become discolored or damaged.
Remove any dirt or debris immediately.
 Observe the general cleaning instructions contained in this chapter.
Do not use a stainless steel cleaner
to clean the control buttons.
Special instructions for glass surfaces
 Glass surfaces can be cleaned using
a cleaning agent specifically designed for glass.
Grease filters
The reusable metal grease filters in the
appliance remove the solid particles
contained in kitchen vapors (fat, dust,
etc.), thereby preventing the ventilation
hood from becoming dirty.
 A dirty filter is a fire hazard!
Cleaning intervals
Over longer periods of time, fat buildup
on the grease filter hardens and makes
cleaning more difficult. Therefore, we
recommend cleaning the grease filters
once every 3-4 weeks.
By illuminating the grease filter symbol,
the filter saturation counter  reminds
you to regularly clean the grease filters.
 You can adjust the interval of the filter
saturation counter to match your
cooking habits (see "Operation").
Removing the grease filters
During removal, the filter may drop to
the ground.
This can result in damage to the filter
and the cooktop.
During cleaning, be sure to hold the
filter securely.
27
Cleaning and care
Cleaning the grease filters in the
dishwasher
 Place the filters as upright as possible
in the lower basket. Ensure that the
spray arm is not obstructed.
 Use a common dishwashing detergent.
 To remove a grease filter, release the
locking clip. Then, open the filter to a
45° angle, unhook it, and remove it
from the hood.
Cleaning the grease filters by hand
 Clean the filters with a soft nylon
brush in a mild solution of hot water
and dish soap. Do not use undiluted
dish soap.
Unsuitable cleaning agents
Unsuitable cleaners can cause damage
to the filter surfaces if used regularly.
Do not use any of the following:
– Lime removers
– Abrasive powders or abrasive liquids
– Aggressive all-purpose cleaners and
degreaser sprays
– Oven sprays
28
 Select a program with a wash temperature between 120°F (50°C) and
150°F (65°C). In a Miele dishwasher
use the "Normal" program.
Depending on the detergent used,
cleaning the filters in a dishwasher
may cause the inside filter surfaces to
become discolored. However, this will
not affect the functioning of the filters
in any way.
After cleaning
 After cleaning, leave the filters on an
absorbent surface to dry.
 When removing the filters for cleaning, also clean off any accessible oil
or fat buildup from the housing. Doing so will prevent a fire hazard.
 Reinstall the grease filters. When inserting the filters, make sure that the
locking clip is facing down.
Cleaning and care
 If the filters have been installed incorrectly, you can insert a small screwdriver into the slit to disengage the
locking clip.
Resetting the filter saturation indicator for the grease filter
Once cleaning is complete, the filter
saturation indicator must be reset.
 While the fan is turned on, press the
grease filter button  for approx. 3
seconds, until only the 1 is flashing.
The grease filter symbol  goes out.
When cleaning the grease filters before
the full operating time has elapsed:
 Press the grease filter button  for
approx. 6 seconds, until only the 1 is
flashing.
OdorFree Charcoal Filter
If the hood is equipped for recirculation,
an OdorFree Charcoal Filter must be installed in addition to the grease filters.
This filter is designed to absorb odorcausing agents and is mounted in the
canopy above the grease filters.
OdorFree Charcoal Filters are available
from your Miele dealer or from Miele.
See "Technical data" for the type and
reference number.
Installing/replacing the OdorFree
Charcoal Filter
 To install or replace the OdorFree
Charcoal Filter, the grease filters must
first be removed as described above.
 Remove the OdorFree Charcoal Filter
from its packaging.
 Press the OdorFree Charcoal Filter
into the frame.
 Reinstall the grease filters.
 When installing the filter for the first
time, activate the filter saturation
counter (see "Operation").
29
Cleaning and care
When to change the OdorFree Charcoal Filter
Disposing of the OdorFree Charcoal
Filter
 Always replace the OdorFree Charcoal Filter whenever it no longer absorbs kitchen odors effectively.
Replace the filter at least once every
6 months.
 Used OdorFree Charcoal Filters can
be disposed of with normal household waste.
The OdorFree Charcoal Filter saturation
counter  will light up to remind you to
change the charcoal filter regularly.
 The OdorFree Charcoal Filter saturation counter requires one-time activation before use (see the "Operation"
chapter).
Resetting the operating hours
counter for the OdorFree Charcoal
Filter
If the operating hours counter is activated, it must be reset each time the filter is changed.
 Press the OdorFree Charcoal Filter
button  for approx. 3 seconds with
the ventilation hood switched on until
only the indicator light for level 1 is
flashing.
The OdorFree Charcoal Filter symbol 
will go out.
If you replace the OdorFree Charcoal
Filter before the full operating time
elapses:
 Press the OdorFree Charcoal Filter
button  for approx. 6 seconds until
only the indicator light for level 1 is
flashing.
30
Installation
Before installation
 Before installing the appliance,
read all of the information contained
in this chapter and also in the "IMPORTANT SAFETY INSTRUCTIONS"
section.
Installation parts
4 extension piece holders
for aligning and securing the telescopic
chimney
4 screws M³/₁₆" x ⁵/₁₆"
(M4 x 8.5 mm)
for securing the extension piece holders.
4 screws, ¹/₄" x 4 ⁵/₁₆"
(7 x 110 mm) and
4 plugs, ³/₈" x 3 ¹/₈" (10 x 80 mm)
for securing the ventilation hood to the
ceiling (not for use in USA / CDN).
The screws and plugs are designed
for use in solid ceilings only.
Use different fasteners for other ceiling construction types. Make sure
that the ceiling can support the load.
14 screws M³/₁₆" x ⁵/₁₆"
(M4 x 8 mm)
for securing the spacer frame and securing the hood to the installation
frame.
1 screw M³/₁₆" x ⁵/₈" (M4 x 16 mm)
for securing the chimney.
DUI 32 recirculation kit for recirculation mode
(not supplied, available as an optional
accessory). The kit includes a directional unit, aluminum hose, and hose
clips.
31
Installation
Appliance dimensions
a Mounting area for the exhaust ducting and power cable. In recirculation mode,
only the power cord is required.
b Possible height range for appliance in vented mode
c Possible height range for appliance in recirculation mode
d Alternative installation with spacer frame
e Air vent positioned at the top for recirculation
32
Installation
f A power cord is required to connect the hood to the socket in the ceiling. With
extraction mode flexible ducting is also required.
Exhaust connection  6" (150 mm)
Distance between cooktop and ventilation hood (S)
Provided a larger distance is not given by the manufacturer of the cooktop, follow the minimum safety distances between a cooktop and the bottom of the
hood.
Please also observe the information contained in the "IMPORTANT SAFETY INSTRUCTIONS" section.
Minimum distance S
Cooking appliance
Miele appliance
Non-Miele appliance
Electric Cooktops
24" (610 mm)
Electric Barbeques and Fryers
26" (660 mm)
Multiburner Gas Cooktops
≤ 43,000 BTU/hr (12.6 kW),
no burner > 15,000 BTU/hr (4.5 kW).
26" (660 mm)
30" (760 mm)
Multiburner Gas Cooktops
≤ 73,800 BTU/hr (21.6 kW),
no burner > 16,500 BTU/hr (4.8 kW)
30" (760 mm)
Multiburner Gas Cooktops
> 73,800 BTU/hr (21.6 kW),
or one of the burners > 16,500 BTU/hr (4.8 kW)
Not possible
Single Burner Gas Cooktops
≤ 20,500 BTU/hr (6 kW)
26" (660 mm)
30" (760 mm)
Single Burner Gas Cooktops
> 20,500 BTU/hr (6 kW)
≤ 27,600 BTU/hr (8.1 kW)
30" (760 mm)
Single Burner Gas Cooktops
> 27,600 BTU/hr (8.1 kW)
Not possible
33
Installation
Installation recommendations
Structural support
– We also recommend a distance of at
least 26" (660 mm) above electric
cooktops to provide more workspace
and easier cooking under the hood.
– When selecting an installation height,
always take the user height into consideration. Users should have ample
space to work comfortably on the
cooktop and reach the ventilation
hood controls with ease.
– Please note that the greater the distance from the cooktop, the less effective the hood is at drawing in the
cooking vapors.
– To achieve optimal vapor extraction,
make sure that the hood covers the
cooktop. The hood should be positioned centrally over the cooktop, not
to the side or rear.
– The cooktop should be no wider than
the hood. Preferably, it should be
narrower.
– The mounting area must be easily accessible. The ventilation hood should
be easy to reach and disassemble in
case a service call is necessary. This
should be taken into consideration
when planning the position of cabinetry, shelves, ceilings or decorative
elements in the vicinity of the ventilation hood.
34
The hood must be attached to rigid
structural framing that is supported
in its entirety by the ceiling joists, or
to the ceiling joists directly. Do not
attach the plate directly to the ceiling
with anchors, toggle bolts, etc.
Removing the protective film
The housing components are covered
by a protective film to prevent them
from damage during transport.
 Please remove this film before installing the housing components. It
can be peeled off easily without any
additional tools.
Installation
85
5/8" m 22 /8"
0
8 m
22
0
mm
 For vented mode:
dai3435aus
 Draw two intersecting lines on the
ceiling.
– Place a section of the exhaust ducting in the ceiling and feed it down
through the cross-sectional area as
illustrated. Exhaust ducting of approx. 27 ⁹/₁₆" (700 mm) length is required between the ceiling and the
hood exhaust socket.
– Secure the exhaust ducting to the exhaust socket, e.g. with a hose clip
(available as an optional accessory)
on flexible ducting.
 Place the power cord and guide it
through the ceiling in the area shown.
A power cord approx. 27 ⁹/₁₆" (700
mm) in length is required between the
ceiling and the hood connectors.
35
Installation
 Use a knife to release the four spacers and the two covers from the
spacer frame supplied.
 Drill four holes  ³/₈" (10 mm), approx. 4 ¹/₂" (115 mm) deep for the
plugs supplied.
 Use the spacer frame as a drilling
template. Place it on the ceiling with
the arrows pointing forwards. Using
the notches, align the spacer frame
on the intersecting lines and make
pencil marks for the drill holes.
36
 Place the four plugs in the holes and
screw in the four screws so that they
protrude by approx. 1 ³/₁₆" (30 mm).
Installation
The spacer frame can be installed between the chimney and the ceiling. This
creates a shadow which gives the illusion of a gap between the ceiling and
the chimney. This is useful if the ceiling
is not level or is uneven. The hood is
aligned vertically with the spacers supplied. Visual irregularities between the
chimney and the ceiling are then concealed by the shadow.
 Mount the spacer frame onto the installation frame.
 If you wish to install the hood with the
spacer frame, remove the four inserts
from the fixing holes.
37
Installation
 Hang the installation frame on the
four screws. The front of the frame is
marked with a "V".
 If using the spacer frame, place the
two covers into the fixing holes.
38
 Align the installation frame and secure it with the screws.
The spacers, which were removed
from the spacer frame at the start,
can be used to align the hood vertically.
Installation
 Holding the installation frame securely, remove the two fixing screws
and extend the installation frame to
its maximum length.
 Replace the screws.
The directional unit from recirculation kit
DUI 32 (optional accessory) is installed
for recirculation mode (RM):
 Bend the four retaining tabs on the
installation frame outwards.
 Place the power cord inside the installation frame.
 Fit the directional unit as shown, noting the marking on the front.
 Bend the retaining tabs back and approx. 45° inwards to hold the directional unit in place.
39
Installation
 Secure the exhaust socket to the
hose using a hose clip.
 Secure the hose to the directional unit
socket using a hose clip.
 Check that the hose is held securely.
 Push the telescopic chimney over the
installation frame:
– with the recirculation grilles at the
bottom for vented mode (AE),
– with the recirculation grilles at the top
for recirculation mode (RM).
 Bend the two retaining tabs outwards
to prevent the telescopic chimney
from slipping down again.
40
Installation
 Fit the four telescopic chimney
clamps. When the screws are tightened, the clamps spread out and
push the telescopic expansion piece
upwards.
 Bend back the two retaining tabs.
 Push the chimney over the telescopic
chimney and bend the retaining tabs
outwards again to prevent the chimney from slipping down again.
Tighten the screws only until the top
edge of the telescopic chimney is
evenly aligned with the ceiling or the
spacer frame.
41
Installation
A non-return flap is supplied with the
hood or is already fitted in the exhaust
socket of the motor unit (depending on
model).
 With vented mode (AE) insert the
non-return flap in the exhaust socket
if your ducting system is not
equipped with one.
Recirculation mode (RM) does not require the non-return flap to be inserted. If there is one present, it
should be removed.
 Hang the hood on the brackets, making sure that the controls are at the
front.
 Secure the hood with the screws
supplied.
42
Installation
 Connect the power cord. See "Electrical connection."
 Unscrew both screws from the installation frame again.
 Place the exhaust ducting onto the
exhaust socket.
The canopy can now be adjusted to the
desired height, observing the permissible height ranges:
– With vented mode: upwards as far as
it will go, downwards only to the "A"
marking.
– With recirculation mode: upwards as
far as the "U", downwards as far as it
will go.
Follow the instructions in "Appliance
dimensions." Safety distances between the cooktop and ventilation
hood must be observed.
43
Installation
 Raise the canopy to the desired
height and secure it with the screws.
 Hold the chimney securely, bend
back the retaining tabs and carefully
lower it.
The chimney will locate in the cut-out in
the canopy.
44
Installation
 With recirculation mode (RM) ventilation hoods, insert the OdorFree Charcoal Filter.
 Remove the grease filters from the
hood.
 Insert the safety screw on the inside.
 Carefully remove the protective foil
from the grease filters.
 Reinsert the grease filters.
45
Exhaust duct
WARNING: Danger of toxic fumes.
Gas cooking appliances release carbon monoxide that can be harmful or
fatal if inhaled.
To reduce the risk of fire and to properly exhaust air, the exhaust gases
extracted by the hood should be
vented outside of the building only.
Do not vent exhaust air into spaces
within walls or ceilings or in attics,
crawl spaces or garages.
To reduce the risk of fire, only use
metal ductwork.
Please read and follow the "IMPORTANT SAFETY INSTRUCTIONS" to
reduce the risk of personal injury.
Follow all local building codes when
installing the hood.
 Only use smooth pipes or flexible
duct hoses made from nonflammable materials for exhaust ductwork.
 To achieve the greatest possible air
extraction with the lowest noise levels, please note the following:
– The diameter of the exhaust duct
should not be less than 6" (150 mm).
– If flat exhaust ducts are used, the
cross section should not be smaller
than that of the exhaust connector.
– The exhaust duct should be as short
and straight as possible.
– If elbows are needed, make sure they
have a large radius.
– The exhaust duct itself must not be
kinked or compressed.
– Make sure that all connections are
secure and airtight.
46
Remember that any constriction of
the airflow will reduce extraction performance and increase operating
noise.
 If the exhaust duct is to be routed
through an outside wall, we recommend installing a telescopic wall vent
or a rooftop vent (available as an optional accessory).
 If the exhaust air is to be conducted
into a vent flue, the intake piece must
be aligned with the flow direction of
the flue.
 When installing the exhaust duct horizontally, you must slope it away from
the source by at least ³/₈" per
3' 3" (1 cm per meter). This ensures
that condensate cannot drain back
into the ventilation hood.
 If the exhaust duct is to be routed
through rooms, ceiling space etc., the
temperatures in these different areas
may differ greatly, which means that
the problem of condensation will
need to be addressed. The exhaust
duct will need to be insulated.
Exhaust duct
Condensate trap
In addition to insulating the exhaust
duct, we recommend installing a condensate trap to collect and evaporate
any condensate which might accumulate.
Condensate traps are available for exhaust ducts with a diameter of
5" (125 mm) or 6" (150 mm).
 When installing a condensate trap,
make sure that it is positioned vertically and, if possible, directly above
the hood outlet duct collar.
The arrow on the housing indicates
the direction of airflow.
47
Electrical connection
WARNING: TO REDUCE THE RISK
OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE
FOLLOWING:
All electrical work should be performed by a qualified electrician in
strict accordance with national regulations (for USA: ANSI-NFPA 70) and
local safety regulations. Installation,
repairs and other work by unqualified
persons could be dangerous.
Ensure that power to the appliance is
OFF while installation or repair work
is performed.
Verify that the voltage, load and circuit rating information found on the
data plate (located behind the baffle
filters), match the household electrical supply before installing the hood.
Use only with ventilation hood cordconnection kits that have been investigated and found acceptable for
use with this model hood.
If there is any question concerning
the electrical connection of this appliance to your power supply, please
consult a licensed electrician or call
Miele’s Technical Service Department.
WARNING: THIS APPLIANCE MUST
BE GROUNDED
48
Grounding Instructions
WARNING - Improper grounding can
result in a risk of electric shock.
This appliance must be grounded. In
the event of an electrical short circuit, grounding reduces the risk of
electric shock by providing a path of
least resistance.plug.
If there is any doubt, have the electrical system of the house checked by
a qualified electrician.
To increase security before the machine is installed, it is recommended
to install a protective switch (30 mA).
 The hood must be hard wired accordingly:
Black/Red wire: connect to L1 (live)
White wire: connect to N (neutral)
Green wire: connect to GND (ground)
Activating Con@ctivity 2.0
Installation of the Con@ctivity
2.0 stick
In order for you to be able to use the
Con@ctivity 2.0 function, the cooktop
must be equipped with a Con@ctivity
2.0 stick.
Activating the ventilation hood
 The cooktop and hood must be
turned off.
 Press the delayed shut down button
 for approx. 10 seconds until 1
lights up in the fan setting display.
 See the relevant installation instructions of the Con@ctivity 2.0 stick.
 Next, tap the following buttons in
succession:
Activating the Con@ctivity 2.0
function
– The 1 button,
To use the Con@ctivity 2.0 function, the
radio link between the cooktop and the
ventilation hood must be activated.
– And then the lighting button .
Both appliances must be installed and
operational.
Wireless connection must be activated
on the ventilation hood and the cooktop
at the same time. Activation on the ventilation hood is described below.
Activation on the cooktop is described
in the relevant operating and installation
instructions. Please refer to the operating instructions before starting.
Activate the ventilation hood first, then
the cooktop.
– Then the IS button,
The hood is in log on / log off mode.
If the wireless connection is already activated, 2 and 3 will light up at the same
time.
If there is no wireless connection, 2 and
3 will flash constantly (Con@ctivity 2.0
is already activated or a remote control
is logged on).
 To activate Con@ctivity 2.0, tap the IS
button.
The search for a wireless connection
will start.
 As this is happening, begin activation
on the cooktop.
49
Activating Con@ctivity 2.0
Activating the cooktop
Activation failed
 While the ventilation hood is searching for a wireless connection, start
activation on the cooktop.
More information can be found in the
operating instructions for the cooktop.
 If a wireless connection cannot be
established despite activation of the
Con@ctivity function on the ventilation hood and cooktop, the function
must first be deactivated and then reactivated on both appliances.
 When the cooktop registers that connection has been established, confirm activation on the ventilation hood
with the delayed shut-down button
515. All indicators will go out.
Deactivating Con@ctivity 2.0
 Confirm activation on the cooktop.
 To deactivate the cooktop, please refer to the corresponding operating instructions.
The Con@ctivity 2.0 function is now
ready for use.
If you do not confirm within 4 minutes,
activation will be canceled.
You only need to carry out the activation procedure once. If the appliances
are disconnected from the electricity
supply, for example during a loss of
power, they will still remain activated.
50
 Deactivation on the ventilation hood
is similar to the activation procedure.
Select the IS instead of the 1 button.
Please keep in mind that disabling the
connection will also disable any remote control function being used. The
remote control must then be reactivated.
Service and warranty
For faults that you cannot resolve on
your own, please contact your Miele
dealer or Miele Technical Service.
MieleCare
The telephone number for Miele is listed
at the back of these instructions.
MieleCare, our Extended Service Contract program, gives you the assurance
of knowing that your appliance investment is covered by 5 years of worry free
ownership.
MieleCare is the only Extended Service
Contract in the industry that guarantees
repairs by a Miele Authorized Service
Provider using genuine Miele parts.
Only genuine Miele parts installed by
factory trained professionals can guarantee the safety, reliability, and
longevity of your Miele appliance.
When contacting Miele, please state the
model and serial number of your ventilation hood.
These can be found on the data plate.
Location of the data plate
The data plate is visible once you have
removed the grease filters.
Warranty
For further information, please refer to
your warranty booklet.
This service is available in USA only.
Please note that unless expressly approved in writing by Miele’s Service department, Extended Service Contracts
offered by other providers for Miele
products will not be recognized by
Miele. Our goal is to prevent unauthorized (and untrained) service personnel
from working on your Miele products,
possibly doing further damage to them,
you and/or your home.
To learn more about MieleCare Extended Service Contracts, please contact your appliance dealer or visit us
online at:
www.mieleusa.com
51
Technical data
Fan motor
Overhead lighting
Total connected load
Voltage, Frequency
Fuse rating
Weight
350 W
4x3W
362 W
120 V AC, 60 Hz
15 A
77 lbs (35 kg)
Optional accessories for recirculation mode:
Recirculation kit DUI 31 and OdorFree Charcoal Filter DKF 12
Contains
FCC ID: 2ACUWEI8800
IC: 5669C-EI8800
This device complies with Part 15 of the FCC Rules and with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may cause undesired
operation.
52
Please have the model and serial number
of your appliance available before
contacting Technical Service.
U.S.A.
Canada
Miele, Inc.
Importer
Miele Limited
National Headquarters
9 Independence Way
Princeton, NJ 08540
Phone: 800-843-7231
609-419-4298
Fax:
www.mieleusa.com
Technical Service & Support
Nationwide
Phone: 800-999-1360
888-586-8056
Fax:
TechnicalService@mieleusa.com
International Headquarters
Miele & Cie. KG
Carl-Miele-Straße 29
33332 Gütersloh
Germany
Headquarters and Miele Centre
161 Four Valley Drive
Vaughan, ON L4K 4V8
www.miele.ca
Customer Care Centre
Phone: 800-565-6435
905-532-2272
customercare@miele.ca
DA 6690 D

en-US
M.-Nr. 09 805 980 / 08
Download PDF