Fisher Paykel | RDV2486GDNN | Planning Guide | Fisher Paykel RDV2486GDNN Planning Guide

Fisher Paykel RDV2486GDNN Planning Guide
4 8" P R O F E SSI O NAL
R A N GE S & B AC KG UARDS
—
RGV2-485GD, RGV2-486GD, RGV2-486GL, RGV2-488,
RDV2-485GD, RDV2-486GD, RDV2-486GL, RDV2-488,
RGV2-485GD-N, RGV2-486GD-N, RGV2-486GL-N, RGV2-488-N,
RDV2-485GD-L, RDV2-486GD-L, RDV2-486GL-L, RDV2-488-L,
BGRV2-1248, BGRV2-3048, BGRV2-3048H models
PLANNING GUIDE
CONTENTS
48" Professional Range
RGV2-485GD, RGV2-486GD, RGV2-486GL, RGV2-488
RDV2-485GD, RDV2-486GD, RDV2-486GL, RDV2-488
in
mm
Key Design Decisions
5
23
Ventilation Requirements
6
24
Product & Cavity Dimensions
7
25
Clearance Dimensions
8
26
Cavity Preparation
9
27
Product & Cavity Dimensions
10
28
Clearance Dimensions
11
29
Cavity Preparation
12
30
Product & Cavity Dimensions
13
31
Clearance Dimensions
14
32
Cavity Preparation
15
33
PAGE
48" Professional Range
RGV2-485GD-N, RDV2-485GD-L
48" Professional Range
RGV2-486GD-N, RDV2-486GD-L
48" Professional Range
RGV2-486GL-N, RDV2-486GL-L
CONTENTS (continued)
48" Professional Range
RGV2-488-N, RDV2-488-L
PAGE
in
mm
Product & Cavity Dimensions
16
34
Clearance Dimensions
17
35
Cavity Preparation
18
36
19
37
20
38
21
39
48" Professional Range Backguard
BGRV2-1248
Product Dimensions
48" Professional Range Backguard
BGRV2-3048
Product Dimensions
48" Professional Range Backguard
BGRV2-3048H
Product Dimensions
IMPERIAL
KEY DESIGN DECISIONS
48" Professional Range
1
2
3
INSTALL TYPE
REAR SURFACE
BACKGUARD OPTIONS
Model no:
RGV2-485GD, RGV2-486GD, RGV2-486GL, RGV2-488
RDV2-485GD, RDV2-486GD, RDV2-486GL, RDV2-488
BGRV2-3048H
ANGLED TRIM
(Supplied with
backguard)
BGRV2-1248
MIN 6"
CLEARANCE
WALL
COMBUSTIBLE
HIGH THICK BACKGUARD
WITH ANGLED TRIM
NO BACKGUARD
LOW THIN BACKGUARD
BGRV2-3048
CUSTOM
BACKGUARD*
MIN 30"
MAX 1/2"
NON COMBUSTIBLE
CUSTOM FABRICATED* BACKGUARD
ISLAND
HIGH THIN BACKGUARD
*Fabricated from non combustible materials only
NO BACKGUARD
DATE: 24.04.2018
IMPORTANT: Throughout this guide, dimensions may vary by ±2mm (1/16'').
Read the installation guide for detailed information on installing the product.
For full installation instructions and specifications visit fisherpaykel.com
VENTILATION REQUIREMENTS
48" Professional Range
1
2
INSTALL TYPE
HOOD SURROUND MATERIAL
Model no:
RGV2-485GD, RGV2-486GD, RGV2-486GL, RGV2-488
RDV2-485GD, RDV2-486GD, RDV2-486GL, RDV2-488
Note: RGV2-366 illustrated but all dimensions apply to the above models
Specifications
23"
23"
Ventilation Unit
Hood
Blower
Ventilation Unit
MIN 30"
MAX 36"
MIN 36"
Hood
Blower
Wall Installation
23'' Deep x Unit Width
1200 CFM
Island Installation
30'' Deep x Unit Width
1200 CFM
Note: A suitable hood must be installed above the range. The above indicates
the minimum blower capacity recommended for hood ventilation.
WALL
NON COMBUSTIBLE
COMBUSTIBLE
30"
30"
MIN 30"
MAX 36"
NON COMBUSTIBLE
ISLAND
MIN 36"
COMBUSTIBLE
DATE: 24.04.2018
IMPORTANT: Throughout this guide, dimensions may vary by ±2mm (1/16'').
Read the installation guide for detailed information on installing the product.
For full installation instructions and specifications visit fisherpaykel.com
PRODUCT & CAVITY DIMENSIONS
48" Professional Range
B 47 7/8''
Model no:
RGV2-485GD-N, RGV2GD-485-L
RDV2-485GD-N, RDV2GD-485-L
Product Dimensions
C
A Overall height of range (from floor to cooktop,
excluding grates and vent trim)
29 1/8''
CABINET FACE FOR
INSTALLATION WITH
PROJECTING CONTROL PANEL
B Overall width of range
47 7/8''
C Overall depth of range (excluding handle and dials)
29 1/8''
D Depth from rear of chassis to cabinetry face - projecting
E Depth from rear of chassis to cabinetry face - flush
CABINET FACE FOR
INSTALLATION WITH
FLUSH CONTROL PANEL
F Height from countertop to top of pan supports
n
q
o
PLAN VIEW
F
DATUM :
1 3/4''
7 3/4''
I Height from countertop to top of door
8 1/16''
J Height from countertop to center of handle
9 7/16''
K Height from countertop to bottom of door
28 7/8''
L Height from countertop to bottom of chassis
35 1/4''
K J I H
31 1/2''
P Depth of handle (measured from front of door)
3 1/16''
R Adjustable feet height
m
A
35 3/4'' 36 3/4''
p
l
1 1/4''
15 1/16''
O Width of right handle (including standoffs)
Q Depth of open door to cabinetry face - flush
TOP OF
COUNTERTOP
1 9/16''
H Height from countertop to bottom of control panel
N Width of left handle (including standoffs)
G
25 1/8''
27 11/16''
G Height from countertop to top of vent trim
M Thickness of handles (not including standoffs)
C 29 1/8''
in
min 35 3/4''
max 36 3/4''
Cavity Dimensions
Overall height of cavity
19 1/8''
min 1/2''
max 1 1/2''
in
min 35 3/4''
max 36 3/4''
Overall width of cavity
min 48''
Overall depth of cavity for projecting control panel
max
25 1/8''
max
27 11/16''
Overall depth of cavity for flush control panel
DATUM : BOTTOM OF CHASSIS
r
q
D
E
B 47 7/8''
INDICATES PRODUCT DATUM --------------------------------------------
FRONT VIEW
0
5
10
PROFILE VIEW
CABINET FACE FOR INSTALLATION
WITH FLUSH CONTROL PANEL
20
inches
CABINET FACE FOR INSTALLATION
WITH PROJECTING CONTROL PANEL
DATE: 24.04.2018
IMPORTANT: Throughout this guide, dimensions may vary by ±2mm (1/16'').
Read the installation guide for detailed information on installing the product.
For full installation instructions and specifications visit fisherpaykel.com
CLEARANCE DIMENSIONS
48" Professional Range
C
C
MINIMUM CLEARANCE:
NEAREST VERTICAL
COMBUSTIBLE SURFACE
Model no:
MINIMUM CLEARANCE:
NEAREST VERTICAL
COMBUSTIBLE SURFACE
D
RGV2-485GD-N, RGV2-485GD-L
MINIMUM CLEARANCE:
COMBUSTIBLE SURFACE
RDV2-485GD-N, RDV2-485GD-L
Clearance Dimensions
A Minimum width of ventilation hood installed above range
- not shown*
E
CABINET FACE FOR
INSTALLATION WITH
PROJECTING CONTROL PANEL
CABINET FACE FOR
INSTALLATION WITH
FLUSH CONTROL PANEL
D
MAXIMUM OVERALL DEPTH
OF OVERHEAD CABINETRY
MINIMUM CLEARANCE:
NON-COMBUSTIBLE SURFACE
in
48''
B Minimum vertical distance between countertop and cabinet
extending above counter
18''
C Minimum clearance from left and right edge of range to
nearest vertical combustible surface
12''
D Minimum clearance from cooking surface to:
––combustible surface centered above the cooking surface
––non-combustible surface centered above the cooking surface
E Maximum overall depth of overhead cabinetry
54''
30''
13''
PLAN VIEW
B
MINIMUM CLEARANCE:
ADJACENT OVERHEAD CABINET
DATUM :
TOP OF COUNTERTOP
DATUM : BOTTOM OF CHASSIS
FRONT VIEW
PROFILE VIEW
INDICATES CABINETRY CLEARANCES --------------------------------INDICATES PRODUCT DATUM --------------------------------------------
DATE: 24.04.2018
0
5
10
CABINET FACE FOR INSTALLATION
WITH FLUSH CONTROL PANEL
20
inches
CABINET FACE FOR INSTALLATION
WITH PROJECTING CONTROL PANEL
IMPORTANT: Throughout this guide, dimensions may vary by ±2mm (1/16'').
Read the installation guide for detailed information on installing the product.
For full installation instructions and specifications visit fisherpaykel.com
CAVITY PREPARATION
48" Professional Range
RGV models
Model no:
RGV2-485GD-N, RGV2-485GD-L
RDV2-485GD-N, RDV2-485GD-L
FINAL POSITION OF
RANGE AGAINST WALL
Location of Electrical and Gas Supply
in
A Depth of supply area (ie maximum protrusion of
gas connection from wall)
2''
B Distance from right hand edge of range to supply area
ELECTRICAL
GAS
C
1 1/2''
C (RGV) Height of electrical supply area (from floor)
19''
D (RGV) Height of gas supply area (from floor)
12''
E (RGV) Width of supply area
D
3''
F (RDV) Distance from left hand edge of range to supply area
1 1/2''
G (RDV) Height of electrical and gas supply area (from floor)
B
E
6''
A
Specifications
Electrical
Supply
Max. Current Draw
Service
Electrical
Supply
Max. Current Draw
Service
RGV Models
120 VAC, 60Hz
15 amp
15 amp circuit
RDV Models
120/240 VAC, 60Hz
40 amp
50 amp circuit
RDV models
Gas – Natural
Connection
FINAL POSITION OF
RANGE AGAINST WALL
Supply Pressure
1/2” NPT Minimum 5/8” dia. flex line
Supply Pressure: 6” to 9” W.C.
Gas – LP
Connection
Supply Pressure*
1/2” NPT Minimum 5/8” dia. flex line
11” to 14” W.C.
A regulator is required at the LP source to provide a maximum pressure
of 14” W.C. to the range regulator.
ELECTRICAL & GAS
G
A
F
B
DATE: 24.04.2018
0
5
10
20
inches
IMPORTANT: Throughout this guide, dimensions may vary by ±2mm (1/16'').
Read the installation guide for detailed information on installing the product.
For full installation instructions and specifications visit fisherpaykel.com
PRODUCT & CAVITY DIMENSIONS
48" Professional Range
B 47 7/8''
Model no:
RGV2-486GD-N, RGV2-486GD-L
RDV2-486GD-N, RDV2-486GD-L
Product Dimensions
C
A Overall height of range (from floor to cooktop,
excluding grates and vent trim)
29 1/8''
CABINET FACE FOR
INSTALLATION WITH
PROJECTING CONTROL PANEL
B Overall width of range
47 7/8''
C Overall depth of range (excluding handle and dials)
29 1/8''
D Depth from rear of chassis to cabinetry face - projecting
E Depth from rear of chassis to cabinetry face - flush
CABINET FACE FOR
INSTALLATION WITH
FLUSH CONTROL PANEL
F Height from countertop to top of pan supports
n
q
o
PLAN VIEW
F
DATUM :
1 3/4''
7 3/4''
I Height from countertop to top of door
8 1/16''
J Height from countertop to center of handle
9 7/16''
K Height from countertop to bottom of door
28 7/8''
L Height from countertop to bottom of chassis
35 1/4''
K J I H
31 1/2''
P Depth of handle (measured from front of door)
3 1/16''
R Adjustable feet height
m
A
35 3/4'' 36 3/4''
p
l
1 1/4''
15 1/16''
O Width of right handle (including standoffs)
Q Depth of open door to cabinetry face - flush
TOP OF
COUNTERTOP
1 9/16''
H Height from countertop to bottom of control panel
N Width of left handle (including standoffs)
G
25 1/8''
27 11/16''
G Height from countertop to top of vent trim
M Thickness of handles (not including standoffs)
C 29 1/8''
in
min 35 3/4''
max 36 3/4''
Cavity Dimensions
Overall height of cavity
19 1/8''
min 1/2''
max 1 1/2''
in
min 35 3/4''
max 36 3/4''
Overall width of cavity
min 48''
Overall depth of cavity for projecting control panel
max
25 1/8''
max
27 11/16''
Overall depth of cavity for flush control panel
DATUM : BOTTOM OF CHASSIS
r
q
D
E
B 47 7/8''
INDICATES PRODUCT DATUM --------------------------------------------
FRONT VIEW
0
5
10
PROFILE VIEW
CABINET FACE FOR INSTALLATION
WITH FLUSH CONTROL PANEL
20
inches
CABINET FACE FOR INSTALLATION
WITH PROJECTING CONTROL PANEL
DATE: 24.04.2018
IMPORTANT: Throughout this guide, dimensions may vary by ±2mm (1/16'').
Read the installation guide for detailed information on installing the product.
For full installation instructions and specifications visit fisherpaykel.com
CLEARANCE DIMENSIONS
48" Professional Range
C
C
MINIMUM CLEARANCE:
NEAREST VERTICAL
COMBUSTIBLE SURFACE
Model no:
MINIMUM CLEARANCE:
NEAREST VERTICAL
COMBUSTIBLE SURFACE
D
RGV2-486GD-N, RGV2-486GD-L
MINIMUM CLEARANCE:
COMBUSTIBLE SURFACE
RDV2-486GD-N, RDV2-486GD-L
Clearance Dimensions
E
CABINET FACE FOR
INSTALLATION WITH
PROJECTING CONTROL PANEL
CABINET FACE FOR
INSTALLATION WITH
FLUSH CONTROL PANEL
D
MAXIMUM OVERALL DEPTH
OF OVERHEAD CABINETRY
MINIMUM CLEARANCE:
NON-COMBUSTIBLE SURFACE
in
A Minimum width of ventilation hood installed above range not shown*
48''
B Minimum vertical distance between countertop and cabinet
extending above counter
18''
C Minimum clearance from left and right edge of range to
nearest vertical combustible surface
12''
D Minimum clearance from cooking surface to:
––combustible surface centered above the cooking surface
––non-combustible surface centered above the cooking surface
E Maximum overall depth of overhead cabinetry
54''
30''
13''
PLAN VIEW
B
MINIMUM CLEARANCE:
ADJACENT OVERHEAD CABINET
DATUM :
TOP OF COUNTERTOP
DATUM : BOTTOM OF CHASSIS
FRONT VIEW
PROFILE VIEW
INDICATES CABINETRY CLEARANCES --------------------------------INDICATES PRODUCT DATUM --------------------------------------------
DATE: 24.04.2018
0
5
10
CABINET FACE FOR INSTALLATION
WITH FLUSH CONTROL PANEL
20
inches
CABINET FACE FOR INSTALLATION
WITH PROJECTING CONTROL PANEL
IMPORTANT: Throughout this guide, dimensions may vary by ±2mm (1/16'').
Read the installation guide for detailed information on installing the product.
For full installation instructions and specifications visit fisherpaykel.com
CAVITY PREPARATION
48" Professional Range
RGV models
Model no:
RGV2-486GD-N, RGV2-486GD-L
RDV2-486GD-N, RDV2-486GD-L
FINAL POSITION OF
RANGE AGAINST WALL
Location of Electrical and Gas Supply
in
A Depth of supply area (ie maximum protrusion of
gas connection from wall)
2''
B Distance from right hand edge of range to supply area
ELECTRICAL
19''
D (RGV) Height of gas supply area (from floor)
12''
E (RGV) Width of supply area
GAS
C
1 1/2''
C (RGV) Height of electrical supply area (from floor)
D
3''
F (RDV) Distance from left hand edge of range to supply area
1 1/2''
G (RDV) Height of electrical and gas supply area (from floor)
B
E
6''
A
Specifications
Electrical
Supply
Max. Current Draw
Service
Electrical
Supply
Max. Current Draw
Service
RDV models
RGV Models
120 VAC, 60Hz
12 amp
15 amp circuit
RDV Models
120/240 VAC, 60Hz
36 amp
50 amp circuit
Gas – Natural
Connection
Supply Pressure
FINAL POSITION OF
RANGE AGAINST WALL
1/2” NPT Minimum 5/8” dia. flex line
Supply Pressure: 6” to 9” W.C.
Gas – LP
Connection
Supply Pressure*
1/2” NPT Minimum 5/8” dia. flex line
11” to 14” W.C.
A regulator is required at the LP source to provide a maximum pressure
of 14” W.C. to the range regulator.
ELECTRICAL & GAS
G
A
F
B
DATE: 24.04.2018
0
5
10
20
inches
IMPORTANT: Throughout this guide, dimensions may vary by ±2mm (1/16'').
Read the installation guide for detailed information on installing the product.
For full installation instructions and specifications visit fisherpaykel.com
PRODUCT & CAVITY DIMENSIONS
48" Professional Range
B 47 7/8''
Model no:
RGV2-486GL-N, RGV2-486GL-L
RDV2-486GL-N, RDV2-486GL-L
Product Dimensions
C
A Overall height of range (from floor to cooktop,
excluding grates and vent trim)
29 1/8''
CABINET FACE FOR
INSTALLATION WITH
PROJECTING CONTROL PANEL
B Overall width of range
47 7/8''
C Overall depth of range (excluding handle and dials)
29 1/8''
D Depth from rear of chassis to cabinetry face - projecting
E Depth from rear of chassis to cabinetry face - flush
CABINET FACE FOR
INSTALLATION WITH
FLUSH CONTROL PANEL
F Height from countertop to top of pan supports
n
q
o
PLAN VIEW
F
DATUM :
1 3/4''
7 3/4''
I Height from countertop to top of door
8 1/16''
J Height from countertop to centre of handle
9 7/16''
K Height from countertop to bottom of door
28 7/8''
L Height from countertop to bottom of chassis
35 1/4''
K J I H
31 1/2''
P Depth of handle (measured from front of door)
3 1/16''
R Adjustable feet height
m
A
35 3/4'' 36 3/4''
p
l
1 1/4''
15 1/16''
O Width of right handle (including standoffs)
Q Depth of open door to cabinetry face - flush
TOP OF
COUNTERTOP
1 9/16''
H Height from countertop to bottom of control panel
N Width of left handle (including standoffs)
G
25 1/8''
27 11/16''
G Height from countertop to top of vent trim
M Thickness of handles (not including standoffs)
C 29 1/8''
in
min 35 3/4''
max 36 3/4''
Cavity Dimensions
Overall height of cavity
19 1/8''
min 1/2''
max 1 1/2''
in
min 35 3/4''
max 36 3/4''
Overall width of cavity
min 48''
Overall depth of cavity for projecting control panel
max
25 1/8''
max
27 11/16''
Overall depth of cavity for flush control panel
DATUM : BOTTOM OF CHASSIS
r
q
D
E
B 47 7/8''
INDICATES PRODUCT DATUM --------------------------------------------
FRONT VIEW
0
5
10
20
inches
PROFILE VIEW
CABINET FACE FOR INSTALLATION
WITH FLUSH CONTROL PANEL
CABINET FACE FOR INSTALLATION
WITH PROJECTING CONTROL PANEL
DATE: 24.04.2018
IMPORTANT: Throughout this guide, dimensions may vary by ±2mm (1/16'').
Read the installation guide for detailed information on installing the product.
For full installation instructions and specifications visit fisherpaykel.com
CLEARANCE DIMENSIONS
48" Professional Range
C
C
MINIMUM CLEARANCE:
NEAREST VERTICAL
COMBUSTIBLE SURFACE
Model no:
MINIMUM CLEARANCE:
NEAREST VERTICAL
COMBUSTIBLE SURFACE
D
RGV2-486GL-N, RGV2-486GL-L
MINIMUM CLEARANCE:
COMBUSTIBLE SURFACE
RDV2-486GL-N, RDV2-486GL-L
Clearance Dimensions
A Minimum width of ventilation hood installed above range
- not shown*
E
CABINET FACE FOR
INSTALLATION WITH
PROJECTING CONTROL PANEL
CABINET FACE FOR
INSTALLATION WITH
FLUSH CONTROL PANEL
D
MAXIMUM OVERALL DEPTH
OF OVERHEAD CABINETRY
MINIMUM CLEARANCE:
NON-COMBUSTIBLE SURFACE
in
48''
B Minimum vertical distance between countertop and cabinet
extending above counter
18''
C Minimum clearance from left and right edge of range to
nearest vertical combustible surface
12''
D Minimum clearance from cooking surface to:
––combustible surface centered above the cooking surface
––non-combustible surface centered above the cooking surface
E Maximum overall depth of overhead cabinetry
54''
30''
13''
PLAN VIEW
B
MINIMUM CLEARANCE:
ADJACENT OVERHEAD CABINET
DATUM :
TOP OF COUNTERTOP
DATUM : BOTTOM OF CHASSIS
FRONT VIEW
PROFILE VIEW
INDICATES CABINETRY CLEARANCES --------------------------------INDICATES PRODUCT DATUM --------------------------------------------
DATE: 24.04.2018
0
5
10
CABINET FACE FOR INSTALLATION
WITH FLUSH CONTROL PANEL
20
inches
CABINET FACE FOR INSTALLATION
WITH PROJECTING CONTROL PANEL
IMPORTANT: Throughout this guide, dimensions may vary by ±2mm (1/16'').
Read the installation guide for detailed information on installing the product.
For full installation instructions and specifications visit fisherpaykel.com
CAVITY PREPARATION
48" Professional Range
RGV models
Model no:
RGV2-486GL-N, RGV2-486GL-L
RDV2-486GL-N, RDV2-486GL-L
FINAL POSITION OF
RANGE AGAINST WALL
Location of Electrical and Gas Supply
in
A Depth of supply area (ie maximum protrusion of gas
connection from wall)
2''
B Distance from right hand edge of range to supply area
ELECTRICAL
GAS
C
1 1/2''
C (RGV) Height of electrical supply area (from floor)
19''
D (RGV) Height of gas supply area (from floor)
12''
E (RGV) Width of supply area
D
3''
F (RDV) Distance from left hand edge of range to supply area
1 1/2''
G (RDV) Height of electrical and gas supply area (from floor)
B
E
6''
A
Specifications
Electrical
Supply
Max. Current Draw
Service
Electrical
Supply
Max. Current Draw
Service
RDV models
RGV Models
120 VAC, 60Hz
12 amp
15 amp circuit
RDV Models
120/240 VAC, 60Hz
36 amp
50 amp circuit
Gas – Natural
Connection
FINAL POSITION OF
RANGE AGAINST WALL
Supply Pressure
1/2” NPT Minimum 5/8” dia. flex line
Supply Pressure: 6” to 9” W.C.
Gas – LP
Connection
Supply Pressure*
1/2” NPT Minimum 5/8” dia. flex line
11” to 14” W.C.
A regulator is required at the LP source to provide a maximum pressure
of 14” W.C. to the range regulator.
ELECTRICAL & GAS
G
F
B
A
DATE: 24.04.2018
0
5
10
20
inches
IMPORTANT: Throughout this guide, dimensions may vary by ±2mm (1/16'').
Read the installation guide for detailed information on installing the product.
For full installation instructions and specifications visit fisherpaykel.com
PRODUCT & CAVITY DIMENSIONS
48" Professional Range
B 47 7/8''
Model no:
RGV2-488-N, RGV2-488-L
RDV2-488-N, RDV2-488-L
Product Dimensions
C
A Overall height of range (from floor to cooktop,
excluding grates and vent trim)
29 1/8''
CABINET FACE FOR
INSTALLATION WITH
PROJECTING CONTROL PANEL
B Overall width of range
47 7/8''
C Overall depth of range (excluding handle and dials)
29 1/8''
D Depth from rear of chassis to cabinetry face - projecting
E Depth from rear of chassis to cabinetry face - flush
CABINET FACE FOR
INSTALLATION WITH
FLUSH CONTROL PANEL
F Height from countertop to top of pan supports
n
q
o
PLAN VIEW
F
DATUM :
1 3/4''
7 3/4''
I Height from countertop to top of door
8 1/16''
J Height from countertop to center of handle
9 7/16''
K Height from countertop to bottom of door
28 7/8''
L Height from countertop to bottom of chassis
35 1/4''
K J I H
31 1/2''
P Depth of handle (measured from front of door)
3 1/16''
R Adjustable feet height
m
A
35 3/4'' 36 3/4''
p
l
1 1/4''
15 1/16''
O Width of right handle (including standoffs)
Q Depth of open door to cabinetry face - flush
TOP OF
COUNTERTOP
1 9/16''
H Height from countertop to bottom of control panel
N Width of left handle (including standoffs)
G
25 1/8''
27 11/16''
G Height from countertop to top of vent trim
M Thickness of handles (not including standoffs)
C 29 1/8''
in
min 35 3/4''
max 36 3/4''
Cavity Dimensions
Overall height of cavity
19 1/8''
min 1/2''
max 1 1/2''
in
min 35 3/4''
max 36 3/4''
Overall width of cavity
min 48''
Overall depth of cavity for projecting control panel
max
25 1/8''
max
27 11/16''
Overall depth of cavity for flush control panel
DATUM : BOTTOM OF CHASSIS
r
q
D
E
B 47 7/8''
INDICATES PRODUCT DATUM --------------------------------------------
FRONT VIEW
0
5
10
20
inches
PROFILE VIEW
CABINET FACE FOR INSTALLATION
WITH FLUSH CONTROL PANEL
CABINET FACE FOR INSTALLATION
WITH PROJECTING CONTROL PANEL
DATE: 24.04.2018
IMPORTANT: Throughout this guide, dimensions may vary by ±2mm (1/16'').
Read the installation guide for detailed information on installing the product.
For full installation instructions and specifications visit fisherpaykel.com
CLEARANCE DIMENSIONS
48" Professional Range
C
C
MINIMUM CLEARANCE:
NEAREST VERTICAL
COMBUSTIBLE SURFACE
Model no:
MINIMUM CLEARANCE:
NEAREST VERTICAL
COMBUSTIBLE SURFACE
D
RGV2-488-N, RGV2-488-L
MINIMUM CLEARANCE:
COMBUSTIBLE SURFACE
RDV2-488-N, RDV2-488-L
Cabinetry Dimensions
A Minimum width of ventilation hood installed above range
- not shown*
E
CABINET FACE FOR
INSTALLATION WITH
PROJECTING CONTROL PANEL
CABINET FACE FOR
INSTALLATION WITH
FLUSH CONTROL PANEL
D
MAXIMUM OVERALL DEPTH
OF OVERHEAD CABINETRY
MINIMUM CLEARANCE:
NON-COMBUSTIBLE SURFACE
in
48''
B Minimum vertical distance between countertop and cabinet
extending above counter
18''
C Minimum clearance from left and right edge of range to
nearest vertical combustible surface
12''
D Minimum clearance from cooking surface to:
––combustible surface centered above the cooking surface
––non-combustible surface centered above the cooking surface
E Maximum overall depth of overhead cabinetry
54''
30''
13''
PLAN VIEW
B
MINIMUM CLEARANCE:
ADJACENT OVERHEAD CABINET
DATUM :
TOP OF COUNTERTOP
DATUM : BOTTOM OF CHASSIS
FRONT VIEW
PROFILE VIEW
INDICATES CABINETRY CLEARANCES --------------------------------INDICATES PRODUCT DATUM --------------------------------------------
0
5
10
CABINET FACE FOR INSTALLATION
WITH FLUSH CONTROL PANEL
20
inches
CABINET FACE FOR INSTALLATION
WITH PROJECTING CONTROL PANEL
DATE: 24.04.2018
IMPORTANT: Throughout this guide, dimensions may vary by ±2mm (1/16'').
Read the installation guide for detailed information on installing the product.
For full installation instructions and specifications visit fisherpaykel.com
CAVITY PREPARATION
48" Professional Range
RGV models
Model no:
RGV2-488-N, RGV2-488-L
RDV2-488-N, RDV2-488-L
FINAL POSITION OF
RANGE AGAINST WALL
Location of Electrical and Gas Supply
in
A Depth of supply area (ie maximum protrusion of
gas connection from wall)
2''
B Distance from right hand edge of range to supply area
ELECTRICAL
19''
D (RGV) Height of gas supply area (from floor)
12''
E (RGV) Width of supply area
GAS
C
1 1/2''
C (RGV) Height of electrical supply area (from floor)
D
3''
F (RDV) Distance from left hand edge of range to supply area
1 1/2''
G (RDV) Height of electrical and gas supply area (from floor)
B
E
6''
A
Specifications
Electrical
Supply
RGV Models
120 VAC, 60Hz
Max. Current Draw
Service
Electrical
Supply
Max. Current Draw
Service
RDV models
9 amp
15 amp circuit
RDV Models
120/240 VAC, 60Hz
33 amp
50 amp circuit
Gas – Natural
Connection
FINAL POSITION OF
RANGE AGAINST WALL
Supply Pressure
1/2” NPT Minimum 5/8” dia. flex line
Supply Pressure: 6” to 9” W.C.
Gas – LP
Connection
Supply Pressure*
1/2” NPT Minimum 5/8” dia. flex line
11” to 14” W.C.
A regulator is required at the LP source to provide a maximum pressure
of 14” W.C. to the range regulator.
ELECTRICAL & GAS
G
F
B
A
DATE: 24.04.2018
0
5
10
20
inches
IMPORTANT: Throughout this guide, dimensions may vary by ±2mm (1/16'').
Read the installation guide for detailed information on installing the product.
For full installation instructions and specifications visit fisherpaykel.com
PRODUCT DIMENSIONS
48" Professional Range Backguard
NOT TO SCALE
BGRV2-1248
Model no:
BGRV2-1248
Product Dimensions
A Height of backguard above vent trim on range
B Overall height of backguard
c 47 7/8''
C Overall width of backguard
D Overall depth of backguard
DATUM : BACK OF PRODUCT
RGV2-488/
RDV2-488
(illustrated)
in
10 3/8''
15 15/16''
47 7/8''
1/2''
E Height of backguard below vent trim on range
5 9/16''
F Depth of backguard below vent trim on range
1/16''
PLAN VIEW
DATUM : BACK OF PRODUCT
d 1/2''
c 47 7/8''
A
10 3/8''
b
DATUM : TOP OF
VENT TRIM ON RANGE
e
f
PROFILE VIEW
0
5
10
FRONT VIEW
INDICATES PRODUCT DATUM --------------------------------------------
DATE: 24.04.2018
20
inches
IMPORTANT: Throughout this guide, dimensions may vary by ±2mm (1/16'').
Read the installation guide for detailed information on installing the product.
For full installation instructions and specifications visit fisherpaykel.com
PRODUCT DIMENSIONS
48" Professional Range Backguard
NOT TO SCALE
BGRV2-3048
C 47 7/8"
Model no:
BGRV2-3048
DATUM : BACK OF PRODUCT
Product Dimensions
A Height of backguard above vent trim on range
D
F
B Overall height of backguard
29 1/8"
C Overall width of backguard
47 7/8"
D Overall depth of backguard and racks
9 5/16"
E Depth of backguard
F Depth of racks
G Width of racks
RGV2-488/
RDV2-488
(illustrated)
H Distance from top of backguard to bottom of racks
G
I Distance from bottom of backguard to bottom of racks
PLAN VIEW
DATUM : BACK OF PRODUCT
in
28 3/8"
1/2"
8 13/16"
45 3/8"
10 15/16"
17 3/8"
J Distance from top of backguard to top of brackets
5 7/8"
K Height of backguard below vent trim on range
13/16"
L Depth of backguard below vent trim on range
1/16"
C 47 7/8"
E 1/2''
J
H
B
A
28 3/8"
I
DATUM : TOP OF
VENT TRIM ON RANGE
PROFILE VIEW
l
FRONT VIEW
k
INDICATES PRODUCT DATUM --------------------------------------------
DATE: 24.04.2018
0
5
10
20
inches
IMPORTANT: Throughout this guide, dimensions may vary by ±2mm (1/16'').
Read the installation guide for detailed information on installing the product.
For full installation instructions and specifications visit fisherpaykel.com
PRODUCT DIMENSIONS
48" Professional Range Backguard with Angled Vent Trim
NOT TO SCALE
B 47 7/8"
BGRV2-3048H
Model no:
BGRV2-3048H
DATUM : BACK OF BACKGUARD
Product Dimensions
f
A Overall height of backguard with angled vent trim
c
h
B Overall width of backguard
47 7/8''
C Overall depth of backguard and racks
10 3/8''
D Height of backguard
26 1/2''
E Height of angled vent trim
3 1/2''
F Depth of angled vent trim
2 7/8''
G Depth of backguard
RGV2-488/
RDV2-488
(illustrated)
1 5/16'''
i
H Depth of racks
9 1/16''
PLAN VIEW
I Width of racks
45 3/8''
DATUM : BACK OF BACKGUARD
g 1 5/16"
in
30''
J Distance from top of backguard to top of racks
5 3/8''
K Distance from bottom of angled vent trim to bottom of racks
18 7/8''
B 47 7/8"
Note: Angled vent trim supplied with BGRV2-3048H.
Remove flat vent trim and replace with angled vent trim.
j
A
d
30"
k
e
DATUM : BOTTOM OF ANGLED VENT TRIM
f
PROFILE VIEW
FRONT VIEW
INDICATES PRODUCT DATUM --------------------------------------------
DATE: 24.04.2018
0
5
10
20
inches
IMPORTANT: Throughout this guide, dimensions may vary by ±2mm (1/16'').
Read the installation guide for detailed information on installing the product.
For full installation instructions and specifications visit fisherpaykel.com
METRIC
KEY DESIGN DECISIONS
48" Professional Range
1
2
3
INSTALL TYPE
REAR SURFACE
BACKGUARD OPTIONS
Model no:
RGV2-485GD, RGV2-486GD, RGV2-486GL, RGV2-488
RDV2-485GD, RDV2-486GD, RDV2-486GL, RDV2-488
BGRV2-3048H
ANGLED TRIM
(Supplied with
backguard)
BGRV2-1248
MIN 152mm
CLEARANCE
WALL
COMBUSTIBLE
HIGH THICK BACKGUARD
WITH ANGLED TRIM
NO BACKGUARD
LOW THIN BACKGUARD
BGRV2-3048
CUSTOM
BACKGUARD*
MIN 762mm
MAX 12.7mm
NON COMBUSTIBLE
CUSTOM FABRICATED* BACKGUARD
ISLAND
HIGH THIN BACKGUARD
*Fabricated from non combustible materials only
NO BACKGUARD
DATE: 24.04.2018
IMPORTANT: Throughout this guide, dimensions may vary by ±2mm (1/16'').
Read the installation guide for detailed information on installing the product.
For full installation instructions and specifications visit fisherpaykel.com
VENTILATION REQUIREMENTS
48" Professional Range
1
2
INSTALL TYPE
HOOD SURROUND MATERIAL
Model no:
RGV2-485GD, RGV2-486GD, RGV2-486GL, RGV2-488
RDV2-485GD, RDV2-486GD, RDV2-486GL, RDV2-488
Note: RGV2-366 illustrated but all dimensions apply to the above models
Specifications
584mm
584mm
Ventilation Unit
Hood
Blower
MIN
762mm
MAX
914mm
Ventilation Unit
914mm
Hood
Blower
Wall Installation
584mm Deep x Unit Width
1200 CFM
Island Installation
762mm Deep x Unit Width
1200 CFM
Note: A suitable hood must be installed above the range. The above indicates
the minimum blower capacity recommended for hood ventilation.
WALL
NON COMBUSTIBLE
COMBUSTIBLE
762mm
762mm
MIN 762mm
MAX 914mm
NON COMBUSTIBLE
ISLAND
914mm
COMBUSTIBLE
DATE: 24.04.2018
IMPORTANT: Throughout this guide, dimensions may vary by ±2mm (1/16'').
Read the installation guide for detailed information on installing the product.
For full installation instructions and specifications visit fisherpaykel.com
PRODUCT & CAVITY DIMENSIONS
48" Professional Range
B 1216
Model no:
RGV2-485GD-N, RGV2-485GD-L
RDV2-485GD-N, RDV2-485GD-L
Product Dimensions
C
A Overall height of range (from floor to cooktop,
excluding grates and vent trim)
740
CABINET FACE FOR
INSTALLATION WITH
PROJECTING CONTROL PANEL
CABINET FACE FOR
INSTALLATION WITH
FLUSH CONTROL PANEL
B Overall width of range
1216
C Overall depth of range (excluding handle and dials)
740
D Depth from rear of chassis to cabinetry face - projecting
638
E Depth from rear of chassis to cabinetry face - flush
703
F Height from countertop to top of pan supports
G Height from countertop to top of vent trim
q
n
o
H Height from countertop to bottom of control panel
PLAN VIEW
F
G
204
240
K Height from countertop to bottom of door
734
L Height from countertop to bottom of chassis
895
K J I H
393
O Width of right handle (including standoffs)
801
R Adjustable feet height
m
A
908 933
p
l
32
N Width of left handle (including standoffs)
Q Depth of open door to cabinetry face - flush
TOP OF
COUNTERTOP
45
196
J Height from countertop to centre of handle
P Depth of handle (measured from front of door)
DATUM :
40
I Height from countertop to top of door
M Thickness of handles (not including standoffs)
C 740
mm
min 908
max 933
Cavity Dimensions
Overall height of cavity
77
486
min 13
max 38
mm
min 908
max 933
Overall width of cavity
min 1219
Overall depth of cavity for projecting control panel
Overall depth of cavity for flush control panel
max 638
max 703
DATUM : BOTTOM OF CHASSIS
r
q
D
E
B 1216
INDICATES PRODUCT DATUM --------------------------------------------
FRONT VIEW
0
100 200
400
millimetres
PROFILE VIEW
CABINET FACE FOR INSTALLATION
WITH FLUSH CONTROL PANEL
CABINET FACE FOR INSTALLATION
WITH PROJECTING CONTROL PANEL
DATE: 24.04.2018
IMPORTANT: Throughout this guide, dimensions may vary by ±2mm (1/16'').
Read the installation guide for detailed information on installing the product.
For full installation instructions and specifications visit fisherpaykel.com
CLEARANCE DIMENSIONS
48" Professional Range
C
C
MINIMUM CLEARANCE:
NEAREST VERTICAL
COMBUSTIBLE SURFACE
D
E
CABINET FACE FOR
INSTALLATION WITH
PROJECTING CONTROL PANEL
CABINET FACE FOR
INSTALLATION WITH
FLUSH CONTROL PANEL
Model no:
MINIMUM CLEARANCE:
NEAREST VERTICAL
COMBUSTIBLE SURFACE
D
RGV2-485GD-N, RGV2-485GD-L
MINIMUM CLEARANCE:
COMBUSTIBLE SURFACE
MAXIMUM OVERALL DEPTH
OF OVERHEAD CABINETRY
MINIMUM CLEARANCE:
NON-COMBUSTIBLE SURFACE
RDV2-485GD-N, RDV2-485GD-L
Clearance Dimensions
mm
A Minimum width of ventilation hood installed above range
- not shown*
1219
B Minimum vertical distance between countertop and cabinet
extending above counter
457
C Minimum clearance from left and right edge of range to
nearest vertical combustible surface
305
D Minimum clearance from cooking surface to:
––ombustible surface centred above the cooking surface
––non-combustible surface centred above the cooking surface
1372
762
E Maximum overall depth of overhead cabinetry
330
PLAN VIEW
B
MINIMUM CLEARANCE:
ADJACENT OVERHEAD CABINET
DATUM :
TOP OF COUNTERTOP
DATUM : BOTTOM OF CHASSIS
FRONT VIEW
PROFILE VIEW
INDICATES CABINETRY CLEARANCES --------------------------------INDICATES PRODUCT DATUM --------------------------------------------
DATE: 24.04.2018
0
100 200
400
millimetres
CABINET FACE FOR INSTALLATION
WITH FLUSH CONTROL PANEL
CABINET FACE FOR INSTALLATION
WITH PROJECTING CONTROL PANEL
IMPORTANT: Throughout this guide, dimensions may vary by ±2mm (1/16'').
Read the installation guide for detailed information on installing the product.
For full installation instructions and specifications visit fisherpaykel.com
CAVITY PREPARATION
48" Professional Range
RGV models
Model no:
RGV2-485GD-N, RGV2-485GD-L
RDV2-485GD-N, RDV2-485GD-L
FINAL POSITION OF
RANGE AGAINST WALL
Location of Electrical and Gas Supply
mm
A Depth of supply area (ie maximum protrusion of gas
connection from wall)
51
B Distance from right hand edge of range to supply area
ELECTRICAL
GAS
C
D
B
E
38
C (RGV) Height of electrical supply area (from floor)
483
D (RGV) Height of gas supply area (from floor)
305
E (RGV) Width of supply area
76
F (RDV) Distance from left hand edge of range to supply area
38
G (RDV) Height of electrical and gas supply area (from floor)
152
A
Specifications
Electrical
Supply
Max. Current Draw
Service
Electrical
Supply
Max. Current Draw
Service
RDV models
RGV Models
120 VAC, 60Hz
15 amp
15 amp circuit
RDV Models
120/240 VAC, 60Hz
40 amp
50 amp circuit
Gas – Natural
Connection
FINAL POSITION OF
RANGE AGAINST WALL
Supply Pressure
1/2” NPT Minimum 5/8” dia. flex line
Supply Pressure: 6” to 9” W.C.
Gas – LP
Connection
Supply Pressure*
1/2” NPT Minimum 5/8” dia. flex line
11” to 14” W.C.
A regulator is required at the LP source to provide a maximum pressure
of 14” W.C. to the range regulator
ELECTRICAL & GAS
G
F
B
A
DATE: 24.04.2018
0 100 200
400
millimetres
IMPORTANT: Throughout this guide, dimensions may vary by ±2mm (1/16'').
Read the installation guide for detailed information on installing the product.
For full installation instructions and specifications visit fisherpaykel.com
PRODUCT & CAVITY DIMENSIONS
48" Professional Range
B 1216
Model no:
RGV2-486GD-N, RGV2-486GD-L
RDV2-486GD-N, RDV2-486GD-L
Product Dimensions
C
A Overall height of range (from floor to cooktop,
excluding grates and vent trim)
740
CABINET FACE FOR
INSTALLATION WITH
PROJECTING CONTROL PANEL
CABINET FACE FOR
INSTALLATION WITH
FLUSH CONTROL PANEL
B Overall width of range
1216
C Overall depth of range (excluding handle and dials)
740
D Depth from rear of chassis to cabinetry face - projecting
638
E Depth from rear of chassis to cabinetry face - flush
703
F Height from countertop to top of pan supports
G Height from countertop to top of vent trim
q
n
o
H Height from countertop to bottom of control panel
PLAN VIEW
F
G
204
240
K Height from countertop to bottom of door
734
L Height from countertop to bottom of chassis
895
K J I H
393
O Width of right handle (including standoffs)
801
R Adjustable feet height
m
A
908 933
p
l
32
N Width of left handle (including standoffs)
Q Depth of open door to cabinetry face - flush
TOP OF
COUNTERTOP
45
196
J Height from countertop to centre of handle
P Depth of handle (measured from front of door)
DATUM :
40
I Height from countertop to top of door
M Thickness of handles (not including standoffs)
C 740
mm
min 908
max 933
Cavity Dimensions
Overall height of cavity
77
486
min 13
max 38
mm
min 908
max 933
Overall width of cavity
min 1219
Overall depth of cavity for projecting control panel
Overall depth of cavity for flush control panel
max 638
max 703
DATUM : BOTTOM OF CHASSIS
r
q
D
E
B 1216
INDICATES PRODUCT DATUM --------------------------------------------
FRONT VIEW
0
100 200
400
millimetres
PROFILE VIEW
CABINET FACE FOR INSTALLATION
WITH FLUSH CONTROL PANEL
CABINET FACE FOR INSTALLATION
WITH PROJECTING CONTROL PANEL
DATE: 24.04.2018
IMPORTANT: Throughout this guide, dimensions may vary by ±2mm (1/16'').
Read the installation guide for detailed information on installing the product.
For full installation instructions and specifications visit fisherpaykel.com
CLEARANCE DIMENSIONS
48" Professional Range
C
C
MINIMUM CLEARANCE:
NEAREST VERTICAL
COMBUSTIBLE SURFACE
D
E
CABINET FACE FOR
INSTALLATION WITH
PROJECTING CONTROL PANEL
CABINET FACE FOR
INSTALLATION WITH
FLUSH CONTROL PANEL
Model no:
MINIMUM CLEARANCE:
NEAREST VERTICAL
COMBUSTIBLE SURFACE
D
RGV2-486GD-N, RGV2-486GD-L
MINIMUM CLEARANCE:
COMBUSTIBLE SURFACE
MAXIMUM OVERALL DEPTH
OF OVERHEAD CABINETRY
MINIMUM CLEARANCE:
NON-COMBUSTIBLE SURFACE
RDV2-486GD-N, RDV2-486GD-L
Clearance Dimensions
mm
A Minimum width of ventilation hood installed above range
- not shown*
1219
B Minimum vertical distance between countertop and cabinet
extending above counter
457
C Minimum clearance from left and right edge of range to
nearest vertical combustible surface
305
d Minimum clearance from cooking surface to:
––combustible surface centred above the cooking surface
––non-combustible surface centred above the cooking surface
1372
762
D Maximum overall depth of overhead cabinetry
330
PLAN VIEW
B
MINIMUM CLEARANCE:
ADJACENT OVERHEAD CABINET
DATUM :
TOP OF COUNTERTOP
DATUM : BOTTOM OF CHASSIS
FRONT VIEW
PROFILE VIEW
INDICATES CABINETRY CLEARANCES --------------------------------INDICATES PRODUCT DATUM --------------------------------------------
DATE: 24.04.2018
0
100 200
400
millimetres
CABINET FACE FOR INSTALLATION
WITH FLUSH CONTROL PANEL
CABINET FACE FOR INSTALLATION
WITH PROJECTING CONTROL PANEL
IMPORTANT: Throughout this guide, dimensions may vary by ±2mm (1/16'').
Read the installation guide for detailed information on installing the product.
For full installation instructions and specifications visit fisherpaykel.com
CAVITY PREPARATION
48" Professional Range
RGV models
Model no:
RGV2-486GD-N, RGV2-486GD-L
RDV2-486GD-N, RDV2-486GD-L
FINAL POSITION OF
RANGE AGAINST WALL
Location of Electrical and Gas Supply
mm
A Depth of supply area (ie maximum protrusion of
gas connection from wall)
51
B Distance from right hand edge of range to supply area
ELECTRICAL
GAS
C
D
B
E
38
C (RGV) Height of electrical supply area (from floor)
483
D (RGV) Height of gas supply area (from floor)
305
E (RGV) Width of supply area
76
F (RDV) Distance from left hand edge of range to supply area
38
G (RDV) Height of electrical and gas supply area (from floor)
152
A
Specifications
Electrical
Supply
Max. Current Draw
Service
Electrical
Supply
Max. Current Draw
Service
RDV models
RGV Models
120 VAC, 60Hz
12 amp
15 amp circuit
RDV Models
120/240 VAC, 60Hz
36 amp
50 amp circuit
Gas – Natural
Connection
FINAL POSITION OF
RANGE AGAINST WALL
Supply Pressure
1/2” NPT Minimum 5/8” dia. flex line
Supply Pressure: 6” to 9” W.C.
Gas – LP
Connection
Supply Pressure*
1/2” NPT Minimum 5/8” dia. flex line
11” to 14” W.C.
A regulator is required at the LP source to provide a maximum pressure
of 14” W.C. to the range regulator.
ELECTRICAL & GAS
G
F
B
A
DATE: 24.04.2018
0 100 200
400
millimetres
IMPORTANT: Throughout this guide, dimensions may vary by ±2mm (1/16'').
Read the installation guide for detailed information on installing the product.
For full installation instructions and specifications visit fisherpaykel.com
PRODUCT & CAVITY DIMENSIONS
48" Professional Range
B 1216
Model no:
RGV2-486GL-N, RGV2-486GL-L
RDV2-486GL-N, RDV2-486GL-L
Product Dimensions
C
A Overall height of range (from floor to cooktop,
excluding grates and vent trim)
740
CABINET FACE FOR
INSTALLATION WITH
PROJECTING CONTROL PANEL
CABINET FACE FOR
INSTALLATION WITH
FLUSH CONTROL PANEL
B Overall width of range
1216
C Overall depth of range (excluding handle and dials)
740
D Depth from rear of chassis to cabinetry face - projecting
638
E Depth from rear of chassis to cabinetry face - flush
703
F Height from countertop to top of pan supports
G Height from countertop to top of vent trim
q
n
o
H Height from countertop to bottom of control panel
PLAN VIEW
F
G
204
240
K Height from countertop to bottom of door
734
L Height from countertop to bottom of chassis
895
K J I H
393
O Width of right handle (including standoffs)
801
R Adjustable feet height
m
A
908 933
p
l
32
N Width of left handle (including standoffs)
Q Depth of open door to cabinetry face - flush
TOP OF
COUNTERTOP
45
196
J Height from countertop to centre of handle
P Depth of handle (measured from front of door)
DATUM :
40
I Height from countertop to top of door
M Thickness of handles (not including standoffs)
C 740
mm
min 908
max 933
Cavity Dimensions
Overall height of cavity
77
486
min 13
max 38
mm
min 908
max 933
Overall width of cavity
min 1219
Overall depth of cavity for projecting control panel
Overall depth of cavity for flush control panel
max 638
max 703
DATUM : BOTTOM OF CHASSIS
r
q
D
E
B 1216
INDICATES PRODUCT DATUM --------------------------------------------
FRONT VIEW
0
100 200
400
millimetres
PROFILE VIEW
CABINET FACE FOR INSTALLATION
WITH FLUSH CONTROL PANEL
CABINET FACE FOR INSTALLATION
WITH PROJECTING CONTROL PANEL
DATE: 24.04.2018
IMPORTANT: Throughout this guide, dimensions may vary by ±2mm (1/16'').
Read the installation guide for detailed information on installing the product.
For full installation instructions and specifications visit fisherpaykel.com
CLEARANCE DIMENSIONS
48" Professional Range
C
C
MINIMUM CLEARANCE:
NEAREST VERTICAL
COMBUSTIBLE SURFACE
D
E
CABINET FACE FOR
INSTALLATION WITH
PROJECTING CONTROL PANEL
CABINET FACE FOR
INSTALLATION WITH
FLUSH CONTROL PANEL
Model no:
MINIMUM CLEARANCE:
NEAREST VERTICAL
COMBUSTIBLE SURFACE
D
RGV2-486GL-N, RGV2-486GL-L
MINIMUM CLEARANCE:
COMBUSTIBLE SURFACE
MAXIMUM OVERALL DEPTH
OF OVERHEAD CABINETRY
MINIMUM CLEARANCE:
NON-COMBUSTIBLE SURFACE
RDV2-486GL-N, RDV2-486GL-L
Clearance Dimensions
mm
A Minimum width of ventilation hood installed above range
- not shown*
1219
B Minimum vertical distance between countertop and cabinet
extending above counter
457
C Minimum clearance from left and right edge of range to
nearest vertical combustible surface
305
D Minimum clearance from cooking surface to:
––combustible surface centred above the cooking surface
––non-combustible surface cent red above the cooking surface
1372
762
E Maximum overall depth of overhead cabinetry
330
PLAN VIEW
B
MINIMUM CLEARANCE:
ADJACENT OVERHEAD CABINET
DATUM :
TOP OF COUNTERTOP
DATUM : BOTTOM OF CHASSIS
FRONT VIEW
PROFILE VIEW
INDICATES CABINETRY CLEARANCES --------------------------------INDICATES PRODUCT DATUM --------------------------------------------
DATE: 24.04.2018
0
100 200
400
millimetres
CABINET FACE FOR INSTALLATION
WITH FLUSH CONTROL PANEL
CABINET FACE FOR INSTALLATION
WITH PROJECTING CONTROL PANEL
IMPORTANT: Throughout this guide, dimensions may vary by ±2mm (1/16'').
Read the installation guide for detailed information on installing the product.
For full installation instructions and specifications visit fisherpaykel.com
CAVITY PREPARATION
48" Professional Range
RGV models
Model no:
RGV2-486GL-N, RGV2-486GL-L
RDV2-486GL-N, RDV2-486GL-L
FINAL POSITION OF
RANGE AGAINST WALL
Location of Electrical and Gas Supply
mm
A Depth of supply area (ie maximum protrusion of
gas connection from wall)
B Distance from right hand edge of range to supply area
ELECTRICAL
GAS
C
D
B
E
51
38
C (RGV) Height of electrical supply area (from floor)
483
D (RGV) Height of gas supply area (from floor)
305
E (RGV) Width of supply area
76
F (RDV) Distance from left hand edge of range to supply area
38
G (RDV) Height of electrical and gas supply area (from floor)
152
A
Specifications
Electrical
Supply
Max. Current Draw
Service
Electrical
Supply
Max. Current Draw
RDV models
Service
RGV Models
120 VAC, 60Hz
12 amp
15 amp circuit
RDV Models
120/240 VAC, 60Hz
36 amp
50 amp circuit
Gas – Natural
Connection
FINAL POSITION OF
RANGE AGAINST WALL
Supply Pressure
1/2” NPT Minimum 5/8” dia. flex line
Supply Pressure: 6” to 9” W.C.
Gas – LP
Connection
Supply Pressure*
F
B
11” to 14” W.C.
A regulator is required at the LP source to provide a maximum pressure
of 14” W.C. to the range regulator.
ELECTRICAL & GAS
G
1/2” NPT Minimum 5/8” dia. flex line
A
DATE: 24.04.2018
0 100 200
400
millimetres
IMPORTANT: Throughout this guide, dimensions may vary by ±2mm (1/16'').
Read the installation guide for detailed information on installing the product.
For full installation instructions and specifications visit fisherpaykel.com
PRODUCT & CAVITY DIMENSIONS
48" Professional Range
B 1216
Model no:
RGV2-488-N, RGV2-488-L
RDV2-488-N, RDV2-488-L
Product Dimensions
C
A Overall height of range (from floor to cooktop, excluding
grates and vent trim)
740
CABINET FACE FOR
INSTALLATION WITH
PROJECTING CONTROL PANEL
CABINET FACE FOR
INSTALLATION WITH
FLUSH CONTROL PANEL
B Overall width of range
1216
C Overall depth of range (excluding handle and dials)
740
D Depth from rear of chassis to cabinetry face - projecting
638
E Depth from rear of chassis to cabinetry face - flush
703
F Height from countertop to top of pan supports
G Height from countertop to top of vent trim
q
n
o
H Height from countertop to bottom of control panel
PLAN VIEW
F
G
204
240
K Height from countertop to bottom of door
734
L Height from countertop to bottom of chassis
895
K J I H
393
O Width of right handle (including standoffs)
801
R Adjustable feet height
m
A
908 933
p
l
32
N Width of left handle (including standoffs)
Q Depth of open door to cabinetry face - flush
TOP OF
COUNTERTOP
45
196
J Height from countertop to centre of handle
P Depth of handle (measured from front of door)
DATUM :
40
I Height from countertop to top of door
M Thickness of handles (not including standoffs)
C 740
mm
min 908
max 933
Cavity Dimensions
Overall height of cavity
77
486
min 13
max 38
mm
min 908
max 933
Overall width of cavity
min 1219
Overall depth of cavity for projecting control panel
Overall depth of cavity for flush control panel
max 638
max 703
DATUM : BOTTOM OF CHASSIS
r
q
D
E
B 1216
INDICATES PRODUCT DATUM --------------------------------------------
FRONT VIEW
0
100 200
400
millimetres
PROFILE VIEW
CABINET FACE FOR INSTALLATION
WITH FLUSH CONTROL PANEL
CABINET FACE FOR INSTALLATION
WITH PROJECTING CONTROL PANEL
DATE: 24.04.2018
IMPORTANT: Throughout this guide, dimensions may vary by ±2mm (1/16'').
Read the installation guide for detailed information on installing the product.
For full installation instructions and specifications visit fisherpaykel.com
CLEARANCE DIMENSIONS
48" Professional Range
C
C
MINIMUM CLEARANCE:
NEAREST VERTICAL
COMBUSTIBLE SURFACE
D
E
CABINET FACE FOR
INSTALLATION WITH
PROJECTING CONTROL PANEL
CABINET FACE FOR
INSTALLATION WITH
FLUSH CONTROL PANEL
Model no:
MINIMUM CLEARANCE:
NEAREST VERTICAL
COMBUSTIBLE SURFACE
D
RGV2-488-N, RGV2-488-L
MINIMUM CLEARANCE:
COMBUSTIBLE SURFACE
MAXIMUM OVERALL DEPTH
OF OVERHEAD CABINETRY
MINIMUM CLEARANCE:
NON-COMBUSTIBLE SURFACE
RDV2-488-N, RDV2-488-L
Clearance Dimensions
mm
A Minimum width of ventilation hood installed above range
- not shown*
1219
B Minimum vertical distance between countertop and cabinet
extending above counter
457
C Minimum clearance from left and right edge of range to
nearest vertical combustible surface
305
D Minimum clearance from cooking surface to:
––combustible surface centred above the cooking surface
––non-combustible surface centred above the cooking surface
1372
762
E Maximum overall depth of overhead cabinetry
330
PLAN VIEW
B
MINIMUM CLEARANCE:
ADJACENT OVERHEAD CABINET
DATUM :
TOP OF COUNTERTOP
DATUM : BOTTOM OF CHASSIS
FRONT VIEW
PROFILE VIEW
INDICATES CABINETRY CLEARANCES --------------------------------INDICATES PRODUCT DATUM --------------------------------------------
0
100 200
400
millimetres
CABINET FACE FOR INSTALLATION
WITH FLUSH CONTROL PANEL
CABINET FACE FOR INSTALLATION
WITH PROJECTING CONTROL PANEL
DATE: 24.04.2018
IMPORTANT: Throughout this guide, dimensions may vary by ±2mm (1/16'').
Read the installation guide for detailed information on installing the product.
For full installation instructions and specifications visit fisherpaykel.com
CAVITY PREPARATION
48" Professional Range
RGV models
Model no:
RGV2-488-N, RGV2-488-L
RDV2-488-N, RDV2-488-L
FINAL POSITION OF
RANGE AGAINST WALL
Location of Electrical and Gas Supply
mm
A Depth of supply area (ie maximum protrusion of gas
connection from wall)
B Distance from right hand edge of range to supply area
ELECTRICAL
GAS
C
D
B
E
51
38
C (RGV) Height of electrical supply area (from floor)
483
D (RGV) Height of gas supply area (from floor)
305
E (RGV) Width of supply area
76
F (RDV) Distance from left hand edge of range to supply area
38
G (RDV) Height of electrical and gas supply area (from floor)
152
A
Specifications
Electrical
Supply
RGV Models
120 VAC, 60Hz
Max. Current Draw
Service
Electrical
Supply
Max. Current Draw
Service
RDV models
9 amp
15 amp circuit
RDV Models
120/240 VAC, 60Hz
33 amp
50 amp circuit
Gas – Natural
Connection
FINAL POSITION OF
RANGE AGAINST WALL
Supply Pressure
1/2” NPT Minimum 5/8” dia. flex line
Supply Pressure: 6” to 9” W.C.
Gas – LP
Connection
Supply Pressure*
1/2” NPT Minimum 5/8” dia. flex line
11” to 14” W.C.
A regulator is required at the LP source to provide a maximum pressure
of 14” W.C. to the range regulator.
ELECTRICAL & GAS
G
F
B
A
DATE: 24.04.2018
0 100 200
400
millimetres
IMPORTANT: Throughout this guide, dimensions may vary by ±2mm (1/16'').
Read the installation guide for detailed information on installing the product.
For full installation instructions and specifications visit fisherpaykel.com
PRODUCT DIMENSIONS
48" Professional Range Backguard
NOT TO SCALE
BGRV2-1248
Model no:
BGRV2-1248
Product Dimensions
c 1210
263
B Overall height of backguard
405
C Overall width of backguard
1210
D Overall depth of backguard
DATUM : BACK OF PRODUCT
RGV2-488/
RDV2-488
(illustrated)
mm
A Height of backguard above vent trim on range
13
E Height of backguard below vent trim on range
142
F Depth of backguard below vent trim on range
1
PLAN VIEW
DATUM : BACK OF PRODUCT
c 1210
d 13
A
263
b
DATUM : TOP OF
VENT TRIM ON RANGE
e
f
PROFILE VIEW
0
100
200
FRONT VIEW
400
millimetres
INDICATES PRODUCT DATUM --------------------------------------------
DATE: 24.04.2018
IMPORTANT: Throughout this guide, dimensions may vary by ±2mm (1/16'').
Read the installation guide for detailed information on installing the product.
For full installation instructions and specifications visit fisherpaykel.com
PRODUCT DIMENSIONS
48" Professional Range Backguard
NOT TO SCALE
BGRV2-3048
C 1216
Model no:
BGRV2-3048
DATUM : BACK OF PRODUCT
Product Dimensions
D
F
720
B Overall height of backguard
740
C Overall width of backguard
1216
D Overall depth of backguard and racks
237
E Depth of backguard
RGV2-488/
RDV2-488
(illustrated)
G
PLAN VIEW
DATUM : BACK OF PRODUCT
mm
A Height of backguard above vent trim on range
13
F Depth of racks
224
G Width of racks
1153
H Distance from top of backguard to bottom of racks
278
I Distance from bottom of backguard to bottom of racks
442
J Distance from top of backguard to top of brackets
149
K Height of backguard below vent trim on range
20
L Depth of backguard below vent trim on range
1
C 1216
E 13
J
H
B
A
720
I
DATUM : TOP OF
VENT TRIM ON RANGE
PROFILE VIEW
l
FRONT VIEW
k
INDICATES PRODUCT DATUM --------------------------------------------
DATE: 24.04.2018
0
100
200
400
millimetres
IMPORTANT: Throughout this guide, dimensions may vary by ±2mm (1/16'').
Read the installation guide for detailed information on installing the product.
For full installation instructions and specifications visit fisherpaykel.com
PRODUCT DIMENSIONS
48" Professional Range Backguard with Angled Vent Trim
NOT TO SCALE
B 1216
BGRV2-3048H
Model no:
BGRV2-3048H
DATUM : BACK OF BACKGUARD
Product Dimensions
f
c
h
763
B Overall width of backguard
1216
C Overall depth of backguard and racks
264
D Height of backguard
673
E Height of angled vent trim
RGV2-488/
RDV2-488
(illustrated)
90
F Depth of angled vent trim
72
G Depth of backguard
33
i
H Depth of racks
230
PLAN VIEW
I Width of racks
1152
J Distance from top of backguard to top of racks
K Distance from bottom of angled vent trim to bottom of racks
DATUM : BACK OF BACKGUARD
g
mm
A Overall height of backguard with angled vent trim
136
480
B 1216
33
Note: Angled vent trim supplied with BGRV2-3048H.
Remove flat vent trim and replace with angled vent trim.
j
A
d
763
k
e
DATUM : BOTTOM OF ANGLED VENT TRIM
f
PROFILE VIEW
FRONT VIEW
INDICATES PRODUCT DATUM --------------------------------------------
DATE: 24.04.2018
0
100
200
400
millimetres
IMPORTANT: Throughout this guide, dimensions may vary by ±2mm (1/16'').
Read the installation guide for detailed information on installing the product.
For full installation instructions and specifications visit fisherpaykel.com
IMPORTANT: The product dimensions and specifications
apply at the date of issue. Under our policy of continuous
product improvement, these dimensions and specifications
may change at any time. Dimensions may vary by ±2mm (1/16").
Please read the installation guide for detailed information
on installing the product or visit fisherpaykel.com.
April 2018
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising