In line with the company’s policy of continual product improvement, the aesthetic and dimensional
characteristics, technical data and accessories of this appliance may be changed without notice.
INSTALLER
GENERAL
INFORMATION
CONTENTS
GENERAL INFORMATION
Conformity And Range
1
The Instructions Before Use
2
Name of Parts
3
Technical Data
4
Outdoor Unit Working Temperature Range
4
Electrical Connections
5
Installing The Outdoor Unit
7
Bleeding
7
Maintenance
8
Installation Dimension Diagram
8
Check After Installation
9
The products in this manual may be different lwith the rea one, according to different models,
some models have displayer and some models without displayer, the position and shape of
the displayer please refer to the real one.
This appliance is not intended for use by persons (including children) with reduced physical,
sensory or mental capabilities, or lack of experience and knowledge, unless they have been
given supervision or instruction concerning use of the appliance by a person responsible for
their safety.
Children should be supervised to ensure that they do not play with the appliance.
Explanation of Symbols
DANGER
Indicates a hazardous situation that, if not avoided, will
result in death or serious injury.
WARNING
Indicates a hazardous situation that, if not avoided, could
result in death or serious injury.
CAUTION
Indicates a hazardous situation that, if not avoided, may
result in minor or moderate injury.
NOTICE
Indicates important but not hazard-related information,
used to indicate risk of property damage.
Indicates a hazard that would be assigned a signal word
WARNING or CAUTION.
GENERAL INFORMATION
CONFORMITY AND RANGE
This appliance can be used by children aged from 8 years and above and persons with reduced physical,sensory
or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction
concerning use of the appliance in a safe way and understand the hazards involved.
Children shall not play with the appliance.
Cleaning and user maintenance shall not be made by children without supervision.
Please read this owner's manual carefully before operating the unit and keep it carefully for consultation.
Instructions for installation and use of this product are provided by the manufacturer.
Only use the air conditioner as instructed in this booklet. These instructions are not intended to
cover every possible condition and situation. As with any electrical household appliance, common sense
and caution are therefore always recommended for installation, operation and maintenance.
1
THE INSTRUCTIONS BEFORE USE
GENERAL INFORMATION
WARNING
★ When having a burning smell or ★ The power supply must adopt the
smoke,please turn off the power
supply and contact with the service center.
special circuit that with air switch
protection and assure it has enough capacity.The unit will be turned
on or off according to your requirement automatically,please do not
turn on or turn off the unit frequently,otherwise disadvantage effect
may be caused to the unit.
★ Never cut off or damage power
cables and control wires. If the
power cable and signal control
wire were damaged, change
them by professional.
If the abnormity still exists,the unit
may be damaged,and may cause
electric shock or fire.
★ Power must adopts the special
★ Disconnect the power supply if
★ Never damage the electric wire
Otherwise, it can cause electric
shock or fire.
Otherwise,the accumulated dusts
may cause overheating or fire.
Otherwise,it will cause overheating
or fire.
★ When cleaning,it is necessary
★ Rated voltage of this air conditi-
★ Don't attempt to repair the air
circuit to prevent fire.
to stop driving and turn off the
power supply.
Cut off power supply
long putting the air conditioner
out of use.
oner 208/230V, 60Hz, The compressor will vibrate sharply if the
voltage is too low, resappointed.
amage to refrigerating system.
Electrical component are easy to
damage if the voltage is too high.
conditioner by yourself.
The wrong repair will lead to an
electric shock or fire,so you should
contact the service center to repair.
Otherwise,it may cause electric
shock or damage.
★ Please note whether the insta-
★ Don't step on the top of the
If it is damaged, it may lead to the
fall of the unit and cause the injury.
As falling off the outdoor unit can be
dangerous.
lled stand is firm enough or not.
or use the electric wire which is
not appointed.
outdoor unit or place something
on it.
2
★ Earthing: The unit must be reli-
ably earthed.The earthing cable
shall be connected to the special earthing device in the construction.
NAME OF PARTS
GENERAL INFORMATION
TM24H4O 、TM30H4O 、TM36H4O
WARNING
Be sure to cut off the power supply before cleaning the air conditioner; otherwise electric
shock might happen.
Wetting of air conditioner may cause the risk of electric shock. Make sure not to wash
your air conditioner in any case.
Volatile liquids such as thinner or gasoline will cause damage to the appearance of air
conditioner. (Only use soft dry cloth moist cloth clean the air conditioner cabinet).
This product must not be disposed together with the domestic waste.
This product has to be disposed at an authorized place for recycling of electrical and
electronic appliances.
The temperature of refrigerant circuit will be high,please keep the interconnection cable
away from the copper tube.
1
OUTDOOR UNIT
No.
Description
1
Air outlet grille
2
Valve
Note: The above figures are only intended to a simple
diagram of the appliance and may not correspond to the
appearance of the units that have been purchased.
70+2 TM30H4O
2
TM36H4O
WARNING
If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similarly
qualified person in order to avoid a hazard.
Be sure to cut off the power supply before cleaning the air conditioner; otherwise electric shock might happen.
Wetting of air conditioner may cause the risk of electric shock. Make sure not to wash your air conditioner in
any case.
Volatile liquids such as thinner or gasoline will cause damage to the appearance of air conditioner. (Only use
soft dry cloth moist cloth clean the air conditioner cabinet).
Do not dispose this product as unsorted municipal waste. Collection of such waste separately for special
treatment is necessary.
The temperature of refrigerant circuit will be high, please keep the interconnection cable away from the copper
tube.
1
OUTDOOR UNIT
No.
Description
1
Air outlet grille
2
Valve
Note: The above figures are only intended to be a simple
diagram of the appliance and may not correspond to
the appearance of the units that have been purchased.
2
3
TECHNICAL DATA
GENERAL INFORMATION
MODE
Electrical data
Electricity supply
Fuse or air switch
Minimum power cord section
TM24H4O
208/230V,60HZ
35
3.3
A
mm 2
L
920
mm
P
380
mm
H
790
mm
Size and clearance
L
P
H
TECHNICAL DATA
GENERAL INFORMATION
TM30H4O
MODE
Electrical data
Electricity supply
Fuse or air switch
Minimum power cord section
208/230V,60HZ
30
3.3
A
mm 2
L
920
mm
P
370
mm
H
787
mm
Size and clearance
L
P
H
TECHNICAL DATA
GENERAL INFORMATION
TM36H4O
MODE
Electrical data
Electricity supply
Fuse or air switch
Minimum power cord section
208/230V,60HZ
35
3.3
A
mm 2
Size and clearance
L
P
H
L
1016
mm
P
362
mm
H
1103
mm
OUTDOOR UNIT WORKING TEMPERATURE RANGE
Maximum cooling
Maximum heating
Outdoor side DB/WB(°F/℃)
118.4(48)/80.6(27)/-
4
GENERAL INFORMATION
ELECTRICAL CONNECTIONS
TM24H4O TM30H4O
INSTALLER
TM36H4O
1. Remove the handle at the right side plate of the outdoor
unit (one screw).
2. Remove the cable clamp, connect the power con
-nection cable with the terminal at the row of conn
-ection and fix the connection. The fitting line distr
-ibuting must be consistent with the indoor unit.
terminal of line bank.
Wiring should meet that of indoor unit.
3. Fix power connection wire by wire clamp.
4. Ensure wire has been fixed well.
5. Install the handle.
An all-pole disconnection switch having a contact
separation of at least 3mm in all pole should be
connected in fixed wiring.
Wrong wire connection may cause malfunction of
some electric components.After fixing cable, ensure
that leads between connection to fixed point have
some space.
The connection pipes and the connectiong wirings
of the unit A and unit B must be corresponding to
each other respective.
The appliance shall be installed in accordance with
national wiring regulations.
Note: the above figures are only intended to be a simple
diagram of the appliance and may not correspond to the
appearance of the units that have been purchased.
TM24H4O
To unit A
To unit B
To unit C
L1 L2
connecting
cable
Power cord
connecting
cable
connecting
cable
To the power supply
yellowgreen
N(1)
2
3
N(1)
2
3
N(1)
2
3
L1 L2
green
white
red
black
)
(blue)
(brown) ( yellowgreen
L1 L2
INDOOR UNIT A
green
white
red
black
)
(blue)
(brown) ( yellowgreen
INDOOR UNIT B
POWER
5
green
white
red
black
)
(blue)
(brown) ( yellowgreen
INDOOR UNIT C
ELECTRICAL CONNECTIONS
INSTALLER
TM30H4O
OUTDOOR UNIT
XT
L1 L2
N( 1) 2
3
PO WER
N (1 ) 2
3
N ( 1) 2
3
PE
PE
N(1 ) 2
L1 L2
3
N(1 ) 2
PE
XT4
XT3
X T2
X T1
N( 1) 2
3
PE
PE
N ( 1) 2
INDO OR UNIT A INDOOR UNIT B
3
3
N(1 ) 2
3
INDO OR UNIT C INDO OR UNIT D
TM36H4O
OU TDOOR UNIT
XT
L1 L2
N(1) 2
3
PE
L1 L2
POWER
N(1) 2
N(1) 2
3
3
INDOOR UNIT A
N(1) 2
3
INDOOR UNIT B
N(1) 2
N(1) 2
3
N(1) 2
PE
PE
XT5
XT4
XT3
XT2
XT1
3
3
6
N(1) 2
3
PE
PE
INDOOR UNIT C
N(1) 2
3
INDOOR UNIT D
N(1) 2
PE
3
INDOOR UNIT E
INSTALLING THE OUTDOOR UNIT
INSTALLER
Location
Caution: Installation Must be Performed in
Accordance with the NEC/CEC by Authorized
Personnel Only.
Install the drain fitting and the drain hose
(for model with heat pump only)
Condensation is produced and flows from the outdoor unit when the appliance is operating in the
heating mode. In order not to disturb neighbours
and to respect the environment,install a drain fitting
and a drain hose to channel the condensate water.
Install the drain fitting and rubber washer on the
outdoor unit chassis and connect a drain hose to it
as shown in the figure.
Use bolts to secure the unit to a flat, solid floor.
When mounting the unit on a wall or the roof, make
sure the support is firmly secured so that it cannot
move in the event of intense vibrations or a strong
wind.
Do not install the outdoor unit in pits or air vents
●
Installing the pipes
Use suitable connecting pipes and equipment for
the refrigerant R410A.
Models(m)
18Kx2 24Kx2 24Kx3 28Kx4
20
60
70
Max. connection pipe length 20
Max. connection pipe length
20
10
10
20
(Simple one indoor unit)
Models(m)
30Kx4 36Kx5 42Kx5
75
75
Max. connection pipe length 70
Max. connection pipe length
25
25
25
(Simple one indoor unit)
The refrigerant pipes must not exceed the maximum
heights 10m(18Kx2&24Kx2&24Kx3&28Kx4&30KX4
&36KX5&42KX5).
Wrap all the refrigerant pipes and joints.
Tighten the connections using two wrenches working in opposite directions.
BLEEDING
INSTALLER
Humid air left inside the refrigerant circuit can cause compressor malfunction. After having connected the indoor
and outdoor units, bleed the air and humidity from the
refrigerant circuit using a vacuum pump.
(1) Unscrew and remove the caps from the 2-way and 3way valves.
(2) Unscrew and remove the cap from the service valve.
(3) Connect the vacuum pump hose to the service valve.
(4) Operate the vacuum pump for 10-15 minutes until an
absolute vacuum of 10 mm Hg has been reached.
(5) With the vacuum pump still in operation, close the
low-pressure knob on the vacuum pump coupling.
Stop the vacuum pump.
(6) Open the 2-way valve by 1/4 turn and then close it
after 10 seconds. Check all the joints for leaks using
liquid soap or an electronic leak device.
(7) Turn the body of the 2-way and 3-way valves. Disconnect the vacuum pump hose.
(8) Replace and tighten all the caps on the valves.
Diameter (mm)
Twisting moment (N.m)
Φ6
15-20
Φ9.52
35-40
Φ16
60-65
Φ12
45-50
Φ19
70-75
Vacuum pump
Vacuum pump
Vacuum pump
(8) Secure
INDOOR
UNIT
Refrigerant fluid direction of fiow
30 36 42Kunit need to be installed the indoor unit
2-way valve
3-way valve
(6) Open by 1/4 turn
(7)Turn to open fully
Service
inlet
(2)Turn
(8) Secure
conversion joint
6
(7)Turn to open fully
Valve cap
(2)Turn
(2)Turn
Valve cap
(8) Secure
Connect to the
indoor unit
MAINTENANCE
INSTALLER
Use suitable instruments for the refrigerant R410A.
● Do not use any other refrigerant than R410A.
Do not use mineral oils to clean the unit.
INSTALLATION DIMENSION DIAGRAM
INSTALLER
The installation must be done by trained and qualified service personnel with reliability according to this
manual.
Contact service center before installation to avoid the malfunction due to unprofessional installation.
When picking up and moving the units, you must be guidedby trained and qualified person.
Ensure that the recommende dspace is left around the appliance.
TM24H4O
TM30H4O
50cm or more
Space to the cover
30cm or above
Space to the cover
30cm or above
(Air inlet side)
200cm or above
(Air outlet side)
5 0 cm o
r a b o ve
S p a ce to
th e w a ll
50cm or more
Space to the cover
TM36H4O
30cm or above
Space to the cover
30cm or above
(Air inlet side)
200cm or above
(Air outlet side)
5 0 cm o
r ab o ve
S p a ce to
th e w a ll
7
CHECK AFTER INSTALLATION
INSTALLER
Check Items
Problems Owing to Improper Installation
Is the installation reliable?
The unit may drop, vibrate or make noises
Has the gas leakage been checked?
May cause unsatisfactory cooling (heating)
effect
Is the thermal insulation of the unit
sufficient?
May cause condensation and water dropping
Is the drainage smooth?
May cause condensation and water dropping
Does the power supply voltage accord
with the rated voltage specified on the
nameplate?
The unit may bread down or the components
may be burned out
Are the lines and pipelines correctly
installed?
The unit may bread down or the components
may be burned out
Has the unit been safely grounded?
Risk of electrical leakage
Are the models of lines in conformity
with requirements?
The unit may bread down or the components
may be burned out
Are there any obstacles near the air
inlet and outlet of the indoor and outdoor units?
The unit may bread down or the components
may be burned out
Have the length of refrigerating pipe
and refrigerant charge amount been
recorded?
It is not easy to decide the charge amount
of refrigerant.
8