C
US
Feel the difference!
Experience the real Comfort
TECHNOLOGY
ULTIMATE COOLING & HEATING SOLUTION
What Klimaire brings you . . .
We have been in Ductless mini-split business since 1989 and at Klimaire maintain the highest quality and reliability
with ISO 9001 and ISO 14001 standards in our manufacturing facilities. Our products have proven their endurance
and resiliency over time operating in 70 different countries since then. All products are ETL certified and AHRI
registered.
Klimaire products exceed industry standards for energy efficiency and employs innovative technology to achieve the
highest customer satisfaction. Since our goal is to achieve maximum customer satisfaction, we continuously seek to
achieve in the design phase of our future units higher performance levels.
Ductless mini-split systems are one of the fastest growing products in the US and popularity is rapidly increasing.
They allow air conditioning and heating systems to be added quickly, economically and conveniently,
often for some applications where installing comfort systems didn't seem possible or practical.
Flexibility is the main role of their popularity.
Klimaire ductless systems are simple, reliable, and easy to install as well as affordable. These systems are integrated
with innovative inverter technology providing individual comfort and control. We are committed to bring you real
comfort with our series to our valuable customers where you Like it, when you Like it and how you Like it.
Light Commercial
Experience the true comfort.
Light Commercial systems are perfect solution to variety of installation challenges, allowing installers the ability to
place ductless mini-split units in locations that were previously impractical or impossible.
They are ideal when additional ductwork is necessary but not cost effectively.
Basically Ductless mini-split units eliminate the use of ductwork.
In addition to eliminating the need for ducting, one of the other great advantages of litht commercial systems is true
zone control.
Each indoor fan coil unit is dedicated to the room being conditioned allowing a temperature and humidity level to be
kept different from the rest of the house or the building.
The Smart Choice...
The US Department of Energy (DOE) says that as much as half of the energy used in your home goes to heating and cooling.
So making smart decisions about your home's heating, ventilating, and air conditioning (HVAC) system can have a big effect
on your utility bills and your comfort.
Klimaire
DC Inverter - driven ductless air conditioners and heat pumps can save you up to 33% in your power
utility bill when compare with room air conditioners or standard efficiency 10 SEER ductless systems. Even up to 30% energy
consumption savings can be achieved when ductless Invertech units are practical to install and preferred over traditional
ducted central units. Total savings can reach up to 60% when the two options are combined.
11%
4%
29%
12%
Heating
Lighting
Cooling
Electronics
(includes computer and monitor
and TV and DVD player)
Water Heating
17%
13%
14%
Appliances
(includes refrigerator, dishwasher,
clothes washer and dryer)
Other*
(includes external power adapters,
telephony, set-top boxes, ceiling fans,
vent fans and home audio)
Inverter Technology:
DC Inverter is a type of power conversion circuit that electronically regulates the voltage, current and frequency of a
compressor or a motor. DC INVERTER-driven air conditioners and heat pumps bear special double cam, twin rotary variable
speed compressor. Like a cruise control of a vehicle. Inverter technology varies the compressor speed based on cooling and
heating needs in the space. Variable speed enables to precisely match system capacity to actual load. They can slow down or
speed up based on demand load. By varying the speed of the compressor systems are able to better match load in heating and
cooling. In multi zone inverter systems the indoor units constantly change capacity and electronically communicate with the
Klimaire outdoor unit to increase or decrease capacity for optimum comfort and save energy. Therefore systems operate more
efficiently at light load, while still being capable of increasing the speed to deliver full capacity when needed.
Since humidity is a major factor for comfort, in the summer, Klimaire DC INVERTER – driven variable speed compressors reduces
capacity to match lighter loads increasing the run time to remove moisture and reduce relative humidity resulting in improved
comfort. In the winter, by increasing the speed of the compressor Klimaire air conditioner and heat pump systems are able to
maintain capacity and deliver hotter supply air even at low outdoor ambient conditions.
Room temperature 77ºF
Humidity 50%
Room temperature 77ºF
Humidity 80%
COMFORTABLE
Decreasing humidity while
maintaining the temperature
increases comfort
UNCOMFORTABLE
Hot and stuffy with high
humidity
Klimaire DC Inverter Technology
Klimaire Invertech DC inverter -driven air conditioners and heat pumps are the ultimate cooling and heating technology of
the HVAC field. Klimaire DC Inverter Technology adopts the new advanced 180 Sine Wave DC inverter driven technology
and brushless DC (BLDC) motor (variable revolution) twin cam compressor. This translates into more energy-savings and
quieter operation than 120 Square- Wave DC inverter types. Result is more consistent temperature which translates into
increased comfort and energy savings all year round.
Room Temperature
DC Inverter 180 Sine Wave
T2 < T1
Room
temperature cool
down to setting
temperature in
shorter time
Fixed Speed System
DC Inverter System
1-Wider frequency & voltage range
2-More Efficient & higher savings
3-Lower noise & reduced vibration for longer life
4-Improved reliable operation
Too Hot
Setting
Temp.
Comfortable
Too Cold
Power Consumption
Fixed Speed System
(Current)
DC Inverter System
Time
T2 T1
Savings and advantages are even much more when you compare
with traditional systems. They run at fixed speed and cycle on/off
to match the load. This will result compressor to draw tremendous
energy each time when it starts up. On/off cycling also reduces the
life-span of the compressor and other components that cycle
on/off.
Time
Eccentric
Load
A high performance double cam
twin rotary compressor increases
the performance, reliability, and
durability. Energy savings are much
higher with this INVERTECH DC
INVERTER - driven variable speed
compressor.
The opposite double blade
advanced design provides
mechanical stability and less
vibration that shall increase the life
of compressor and other
components in the outdoor unit.
Homeowners and neighbors enjoy
quiet whisper breeze outdoor unit
operation making sure nobody is
disturbed.
The temperature fluctuations are much higher in traditional (on/off
cycling) systems compared to invertech driven inverter systems, which
effects human comfort.
Real comfort does not only depend on temperature. Dehumidification
process, especially during hot sticky weather is essential and integral
part of cooling and inverter systems are the more efficient way to
remove moisture and control humidity level.
Temperature Fluctuation
- INVERTECH System vs. On/off System
Flexible and Quiet
Noise Level
Like regular split air conditioning or
heat pump systems, the condensing
unit is installed outdoors allowing a
peaceful and more comfortable
interior environment.
dB(A) Level
140
Jet Engine
at 100’
105
Power
Tools
70
Normal
Conversation
from 3 - 5’
35
Whisper
Quiet
Library
0
Weakest
Sound
Heard
Cassette
+
Klimaire
KSIL Unit
Floor / Ceiling
+
12,000 - 48,000
12,000 - 48,000
KTIM + KSIL
KUIM + KSIL
Ducted Recessed
+
12,000 - 48,000
KDIM + KSIL
Console
+
12,000 btu
KFIM + KSIL
Respected for its reliability
Desired for its all season performance
Energy Savings – Reduction of up to 60% in energy
consumption can be achieved in comparison to 10 SEER units,
which will reduce the utility bill.
Quieter operation – It is less noisy than a self contained
window unit, or a packaged terminal unit (PTAC / PTHP), or a
central unit. A ductless split system is ultra-quiet because it
does not have to push conditioned air through many feet of
ductwork, and the nosier outdoor portion of the system
operates outdoors.
Comfort – A true temperature control optimizes your comfort.
Klimaire INVERTECH advanced DC Inverter technology provides
maximum comfort for the entire space by individual
temperature and humidity control. By utilizing inverter
technology, temperature and humidity fluctuations are
minimized, this state-of-the-art electronic climate control also
changes the louver direction swings air, to create uniform
ambient conditions. When the selected temperature is reached
an inverter system runs almost constantly at low economy
speed to maintain desired comfort level controlling humidity
which is considered vital for comfort.
Powerful – By means of a microprocessor Inverter Technology
senses the indoor air temperature of the space being cooled or
heated and adjusts the speed of the compressor to run at
higher speed to meet the demand and quickly reach the set
temperature, then slows down to lower rotation speed to
maintain it.
Convenient – Excellent for remodeling older homes,
convenient for retrofitting, vacation homes, cabins, classrooms,
churches, nursing homes, restaurants, computer rooms, sun
rooms, ATMs, office lobbies and remote offices.
Environmentally Friendly – Our units use environmentally
friendly R-410A refrigerant designed to prevent
the depletion of the ozone layer. Our super high efficiency
products contribute to reduce fossil fuel
consumption and limit air pollution.
KTIM
The KTIM cassette unit provides cooling and heating capacity with the 360º flow system allows distributing comfort
to every corner of the room; additionally it can share this capacity with an adjacent room by means of flex duct
connection; exposed decorative panel 4-way distribution. The off-white color blends with any ceiling configuration.
* The removable panel makes the clean process much easier.
* Fresh air intake design
* Easy maintenance built-in drain pump
*Terminals for connecting an alarm and long distance on-off control
* Auto re-start function can be set up on the main PCB
* These units can be installed as a two zone system combined in any of the different
available capacities.
* Remote controlled
* Sleep mode
* Grille and indoor unit are shipped in separate boxes
* 12,000 Btu & 18,000 Btu models are available
KDIM
The KDIM hideaway, low profile slim design allows installation above a drop ceiling or attic space easily, no floor
space or cabinet build-up required. The unit is less than 9" in height. Back air inlet is standard, and bottom is
optional. The bottom and back flange plate size is the same, which makes it easy to exchange installation return air
opening from back to bottom. Unit is ideal to cool several zones, such as bedroom and bathroom in residences;
foyer, bathroom, and bedroom combinations in commercial applications.
* Standard fresh air hole, easy air duct connection
* Wired control
* Independent dehumidification
* Anti-cold air function
* Sleep mode
* 12,000 Btu & 18,000 Btu models are available
KUIM
The KUIM unique decorative and versatile design allows the unit to be suspended from
the ceiling or placed low on the wall or simply placed on the floor. Extremely quiet, and rugged
construction makes it ideal for areas of heavy traffic and public areas .They are perfect for
residential or commercial applications.
* Attractive, modern design
* Exceptionally quiet operation
* Ease of service and installation
* Anti-cold air function
* Auto restart function
* Auto defrosting
* Sleep mode
* 12,000 Btu & 18,000 Btu models are available
KFIM
Klimaire KFIM console fan coils are designed and engineered to provide with its
innovative style years of reliable operation, energy-efficient, and unmatched comfort,
and many years of trouble-free performance.
* Wide angle air flow
* Quiet and fashion design
* Air inlet from 4 direction, and two optional air outlet ways
* Low noise, energy saving.
* Sleep mode
* 12,000 Btu & 18,000 Btu models are available
GENERAL SPECIFICATIONS
C
US
Light Commercial Series KSIO Outdoor Units
KSIO Outdoor Unit
Klimaire Model No.
KSIO012-H223-O
KSIO018-H221-O
KSIO024-H218-OC
V- Ph-Hz
230-1-60
230-1-60
230-1-60
Max. fuse
A
15
20
25
Minimum circuit ampacity
A
8
13
15
1
1
1
r/min
850/580
750/500
850
cfm
1295
1471
2060
Power supply
Ourdoor fan motor
Qty
Speed
Outdoor air flow
Outdoor noise level
dB(A)
Throttle type
Outdoor unit
Refrigerant type/Quantity
Ambient temperature
60,5
61
Capillary
Capillary + EXV
Dimension (W×D×H)
in
Packing (W×D×H)
in
35" x 14" x 25"-3/8
38" x 15"-5/8 x 29"-11/16
41" x 15"-5/8 x 36"
Net/ Gross weight
lb
87 /92.4
104.5 / 112.2
30"-1/8 x 11"-1/8 x 23"-1/4 33"-1/4 x 13"-3/16 x 27"-13/32 35"-3/16 x 12"-3/16 x 33"-7/8
159 /168
R410A
R410A
R410A
oz
56,53
61,83
89,6
psig
340
340
340
Liquid side/ Gas side
in
1/4" / 1/2"
3/8" / 5/8"
3/8" / 5/8"
Max. pipe length
ft
35
98
160
Max. difference in level
ft
33
65
80
Cooling
ºF
0~50
5~122
5~122
Heating
ºF
5~75
5~75
5~75
Type
Charged volume
Design pressure
Refrigerant piping
55
Capillary
Remarks:1.The above design and specifications are subject to change without prior notice for product improvement.
2.The values given in the table for the noise level reflect the levels in anechoic chamber.
H
H
W
D
W
D
GENERAL SPECIFICATIONS
C
Light Commercial Series KSIL Outdoor Units
Outdoor Unit
Klimaire Model No.
KSIL012-H219-O
KSIL018-H219-O
KSIL024-H219-OC
V- Ph-Hz
230-1-60
230-1-60
230-1-60
Max. fuse
A
15
20
25
Minimum circuit ampacity
A
8
13
15
1
1
1
r/min
850/580
750/500
850
cfm
1295
1471
2060
dB(A)
55
60,5
61
Capillary
Capillary
Capillary + EXV
Power supply
Ourdoor fan motor
Qty
Speed
Outdoor air flow
Outdoor noise level
Throttle type
Outdoor unit
Refrigerant type/Quantity
Dimension (W×D×H)
in
Packing (W×D×H)
in
35" x 14" x 25"-3/8
38" x 15"-5/8 x 29"-11/16
41" x 15"-5/8 x 36"
Net/ Gross weight
lb
87 /92.4
104.5 / 112.2
159 /168
R410A
R410A
R410A
Oz
56,53
61,83
89,6
psig
340
340
340
Liquid side/ Gas side
in
1/4" / 1/2"
3/8" / 5/8"
3/8" / 5/8"
Max. pipe length
ft
35
98
160
Max. difference in level
ft
33
65
80
Cooling
ºF
0¡« 50
5~122
5~122
Heating
ºF
5~75
5~75
5~75
Type
Charged volume
Design pressure
Refrigerant piping
Ambient temperature
30"-1/8 x 11"-1/8 x 23"-1/4 33"-1/4 x 13"-3/16 x 27"-13/32
35"-3/16 x 12"-3/16 x 33"-7/8
KSIL036-H215
KSIL048-H216
Power supply
V / ph / Hz
208-230/1/60
208~230-1-60
Max. fuse size
A
50
55
Minimum circuit ampacity
A
30
35
n
1
2
rpm
860
1000
4240
Outdoor fan motor
Qty
Speed
Outdoor air flow (Max.)
cfm
3240
Outdoor noise level
dB(A)
66
64
Refrigerant gas throttle
Type
Capillary +EXV
Capillary +EXV
Dimension (W×D×H)
in
38.98x13.58x37.99
36.93x15.43x53.9
Packing (W×D×H)
in
44.09x17.13x43.31
43.11x19.49x59.25
Net/ Gross weight
lb
160.94/182.98
220.46/251.33
Type
oz.
R410A
R410A
Charge volume
oz.
97
152
psig
550/340
550/340
Liquid side/ Gas side
in
3/8" / 5/8"
3/8" / 5/8"
Max. pipe length
ft
213
213
Max. level difference
ft
98
98
Cooling
℉
℉
5~122
5~122
5~76
5~76
Outdoor unit
Refrigerant gas
Design pressure
Refrigerant piping
Ambient temperature
Heating
Remarks:1.The above design and specifications are subject to change without prior notice for product improvement.
2.The values given in the table for the noise level reflect the levels in anechoic chamber.
H
H
H
L
KSIL012 - 024
D
L
KSIL036
D
L
KSIL048
D
US
GENERAL SPECIFICATIONS
C
US
Light Commercial Series KTIM Indoor Units
Indoor Unit
Klimaire Model No.
Power supply
Cooling
Capacity
Heating
SEER
Capacity
Indoor fan motor
HSPF
Qty
Unit Dimensions
KTIM012-H2
KTIM018-H2
KTIM024-H2
V-ph-Hz
208~230-1-60
208~230-1-60
220-1-60
Btu/h
12.000
18.000
23.800
16,5
17
15,8
12.400
18.400
23.800
9,6
8,8
9,5
1
1
1
Btu/h
Speed(Hi/Med/Lo)
r/min
760/730/620
760/730/620
580±20
Chassis (WxDxH)
in
22"-7/16 x 22"-7/16 x 10"-1/4
22"-7/16 x 22"-7/16 x 10"-1/4
33"-1/16 x 33"-1/16 x 8"-1/16
Packing (WxDxH)
in
25"-25/32 x 25"-25/32 x 11"-7/16
25"-25/32 x 25"-25/32 x 11"-7/16
35"-7/16 x 35"-7/16 x 8"-7/8
Panel (WxDxH)
in
25"-15/32 x 25"-15/32 x 1"-31/32
25"-15/32 x 25"-15/32 x 1"-31/32
37"-13/32 x 37"-13/32 x 2"-3/16
Packing (WxDxH)
in
28"-1/8 x 28"-1/8 x 4"-27/32
28"-1/8 x 28"-1/8 x 4"-27/32
40"-3/4 x 40"-3/4 x 3"-1/2
Chassis Net/Gross weight
lb
35.2 / 41.8
39.6 / 46.2
45.1 / 52.8
Panel Net/Gross weight
lb
5.5 / 9.9
5.5 / 9.9
11 / 17.6
psig
340
340
340
OD Φ1"-1/4
Design pressure
Drainage water pipe diameter
in
OD Φ 1/4
OD Φ 1/4
Refrigerant piping
in
1/4" / 1/2"
3/8" / 5/8"
3/8" / 5/8"
RG05F2/BGEU1
RG05F2/BGEU1
RG05F2/BGEU1
Liquid side/Gas side
Controller
Operation
Cooling
ºF
?63
?63
?63
Temperature
Heating
ºF
?86
?86
?86
KTIM036-H2
KTIM048-H2
V /ph / Hz
208~230-1-60
208~230-1-60
Btu/h
36.000
46.000
—
15
15,5
Btu/h
36.000
47.000
—
9,0
9,0
n
1
1
rpm
720/630/560
720/630/560
in
33.07x33.07x9.65
33.07x33.07x11.3
in
35.43x35.43x10.43
35.43x35.43x11.5
in
37.4x37.4x2.17
37.4x37.4x2.17
in
40.75x40.75x3.54
40.75x40.75x3.54
lb
55.12/62.83
63.93/73.85
lb
11.02/17.64
11.02/17.64
psig
550/340
550/340
in
ODΦ 1"-1/4
ODΦ 1"-1/4
Indoor Unit Model Number
Power supply
Cooling
Capacity
SEER
Heating
Capacity
HSPF
Indoor fan motor Qty
Speed (Hi/Med/Lo)
Indoor unit
Dimension (W x Dx H)
Packing (W x Dx H)
Panel Dimension (W x Dx H)
Panel Packing (W x Dx H)
Unit Net/Gross weight
Panel Net/Gross weight
Design pressure
Drainage water pipe dia.
Refrigerant lines
Liquid / Gas
Controller
Room temperature Cooling
Heating
Operation temperature
in
3/8" / 5/8"
3/8" / 5/8"
—
RG05F2/BGEU1
RG05F2/BGEU1
℉
℉
℉
62~90
62~90
32~86
32~86
62~86
62~86
H
Remarks:1.The above design and specifications are subject to change without prior notice for product improvement.
2.The values given in the table for the noise level reflect the levels in anechoic chamber.
W
L
GENERAL SPECIFICATIONS
C
US
Light Commercial Series KUIM Indoor Units
Indoor Unit
Klimaire Model No.
Power supply
Cooling
Heating
Indoor fan motor
KUIM018-H2
KUIM024-H2
V-ph-Hz
208~230-1-60
208~230-1-60
220-1-60
Capacity
Btu/h
12.000
18.000
25.000
SEER
Capacity
19
16
17
Btu/h
12.400
18.400
26.000
HSPF
Qty
Speed(Hi/Med/Lo)
Indoor unit
KUIM012-H2
9,1
8,5
8,9
n
1
1
1
r/min
Dimension (WxDxH)
in
1300±20
39" x 26" x 8"
1300±20
39" x 26" x 8"
1300±20
42" x 26"-9/16 x 9"-1/4
Packing (WxDxH)
in
42"-29/32 x 29"-5/16 x 11"-11/16
42"-29/32 x 29"-5/16 x 11"-11/16
45"-1/16 x 29"-23/32
lb
48.4 / 61.6
52.8 / 66
55 / 66
psig
340
340
340
Net/Gross weight
Design pressure
Drainage water pipe diameter
in
Φ 1"
Φ 1"
Φ 1"
Refrigerant piping
Liquid side/Gas side
in
1/4" / 1/2"
3/8" / 5/8"
3/8" / 5/8"
RG05F2/BGEU1
RG05F2/BGEU1
RG05F2/BGEU1
Cooling
ºF
?63
?63
?63
Heating
ºF
?86
?86
?86
Controller
Operation
temperature
Indoor unit model number
KUIM036-H2
KUIM048-H2
V/ph/Hz
208-230/1/60
208-230/1/60
Btu/h
36.000
48.000
—
15
16
Btu/h
36.000
49.000
—
9,0
10,0
n
1
2
Speed (Hi/Med/Lo)
rpm
1300/1150/800
1320/1200/1120
Dimension (WxDxH)
Packing (WxDxH)
in
50.59x26.57x9.25
64.96x26.57x9.25
in
53.54x29.72x12.32
67.91x29.72x12.32
lb
66.14/77.16
83.78/97
psig
550 / 340
550 / 340
Power supply
Cooling
Capacity
SEER
Heating
Capacity
HSPF
Indoor fan motor Quantity
Indoor unit
Net/Gross weight
Design pressure
Drainage water pipe diameter
in
OD Ф1"
OD Ф1"
Liquid /Gas
in
3/8" / 5/8"
3/8" / 5/8"
—
RG05F2/BGEU1
RG05F2/BGEU1
℉
℉
62~90
62~90
32~86
32~86
Refrigerant piping
Controller
Room temperature
Cooling
Heating
H
Remarks:1.The above design and specifications are subject to change without prior notice for product improvement.
2.The values given in the table for the noise level reflect the levels in anechoic chamber.
L
GENERAL SPECIFICATIONS
C
Light Commercial Series
KFIM Indoor Units
Indoor Unit
Klimaire Model No.
KFIM012-H2
Power supply
Cooling
Capacity
V-ph-Hz
208~230-1-60
Btu/h
12.000
Btu/h
12.000
17,6
SEER
Heating
Capacity
10
HSPF
Qty
Indoor fan motor
Indoor unit
1
Input
W
28
Capacitor
uF
/
Speed(Hi/Med/Lo)
rpm
890/840/780/680/530
Dimension (W x Dx H)
in
27"-9/16 x 23"-5/8 x 8"-1/4
Packing (W x Dx H)
in
31"-29/32 x 27"-31/32 x 12"
Net/Gross weight
lb
33 / 44
Design pressure
psig
340
Drainage water pipe dia.
in
OD Φ5/8
Refrigerant piping
Liquid side/ Gas side
in
1/4" / 1/2"
Cooling
ºF
?63
Heating
ºF
?86
Controller
Operation
temperature
RG05F2/BGEU1
H
L
Remarks:1.The above design and specifications are subject to change without prior notice for product improvement.
2.The values given in the table for the noise level reflect the levels in anechoic chamber.
US
GENERAL SPECIFICATIONS
C
US
Light Commercial Series
KDIM Indoor Units
Ducted Recessed
KDIM012-H2
KDIM018-H2
KDIM024-H2
V-ph-Hz
208~230-1-60
208~230-1-60
220-1-60
Btu/h
12.000
18.000
24.000
15,5
15,5
16,5
12.200
18.600
25.000
9,3
8,6
8,2
1
1
1
Klimaire Model No.
Power supply
Cooling
Capacity
SEER
Heating
Btu/h
Capacity
HSPF
Qty
Indoor fan motor
Input
W
71/48.8/36.7
119/56/43
90
Capacitor
uF
2UF/450V
3.5UF/450V
\
rpm
1255/1005/850
Pa
1170/790/690
70
1000±20
40
Speed(Hi/Med/Lo)
Indoor external static pressure (Hi)
Indoor noise level (Hi/Med/Lo)
Indoor unit
dB(A)
38/36/32
42/36/32
49/47/44
Dimension (WxDxH)
in
27"-9/16 x 25" x 8"-17/64
36"-7/32 x 25" x 8"-17/64
36"-7/32 x 25" x 10"-5/8
Packing(WxDxH)
in
36" x 25"-25/32 x 11"-3/8
44"-11/16 x 25"-25/32 x 11"-3/8
44"-11/16 x 25"-25/32 x 13"-25/32
lb
44 / 55
340
51 / 64
340
66 / 77
psig
Net/Gross weight
Design pressure
Drainage water pipe diameter
Refrigerant piping Liquid side/ Gas side
340
in
1/2
in
1/4" / 1/2"
1/2
3/8" / 5/8"
3/8" / 5/8"
KJR-10B/DP(T)-F
KJR-10B/DP(T)-F
KJR-10B/DP(T)-F
?63
?63
?86
?86
Controller
Operation
temperature
70
Cooling
ºF
?63
Heating
ºF
?86
H
L
L
Remarks:1.The above design and specifications are subject to change without prior notice for product improvement.
2.The values given in the table for the noise level reflect the levels in anechoic chamber.
1/2
5Year
1Year
on Compressor
on Parts
Warranty
Warranty
2190 NW 89 Place
Doral, FL 33172 – USA
Tel: (305)594-4972 - Fax (305) 499-4378
www.klimaire.com - sales@klimaire.com