Miele 52880705USA Installation Plan (Electric)

Miele 52880705USA Installation Plan (Electric)
Installation plan
Tumble dryer
PT 8807 EL (Electrically heated)
en - US
38.15
Mat. NR. 09 883 210 / 02
U.S.A.
Miele, Inc.
National Headquarters
9 Independence Way
Princeton, NJ 08540
Phone: 800-991-9380
Fax:
609-419-4241
www.mieleusa.com
Technical Service & Support
Nationwide
Phone: 800-991-9380
Fax:
800-220-1348
[email protected]
It is essential to read the operating and installation instructions before
installing, commissioning or using the machine.
This avoids the risk of accidents or damage.
All rights reserved
Mat. NR. 09 883 210 / 02
2
Technical datasheet
Tumble dryer:
Heating:
PT 8807
Electric (EL)
Legend:
en - US
Abbreviations in bold type:
Connection required
Abbreviations in circle with dashes:
Connection optional or required depending on model version
Optional extras:
BS
Concrete base
Quality and density of concrete must comply with load.
Concrete plinth must be firmly secured to floor!
Recommended height
Minimum height
Minimum width
Minimum depth
4“
2“
47“
55“
mm
mm
mm
mm
100
50
1.200
1.400
V
Hz
kW
A
mm²
3 AC 208
60
27.4
3 × 90
AWG 16
M 50
mm
M
10 × 35
10
V
mm²
AC 230
5 × 1,5
Max. Nominal air flow in vented mode
Max. Permissible pressure loss
m³/h
Pa
1.100
300
38,85 cu ft/h
0.04 PSI
Connection on machine side (ext. diameter)
Connection pipe provided on site (int. diameter)
Max. temperature
mm
mm
°C
150
150
80
6“
6“
176 °F
Machine connections:
Voltage
Frequency
Rated load
Fuse rating
Connection cable, min. cross-section
Cable screw connector
Electrical
connection
Connection cable to be ordered separately.
Electrical connection must comply with national
regulations
If machines are hard-wired, a multi-pole main switch must
be provided on site.
A wall socket or main isolator must be accessible after
installation.
Equipotential
bonding
Connection with male thread
with washers and nut
Accessories not included.
If necessary, equipotential bonding with good galvanic
contact must be provided in accordance with all
appropriate national and local regulations.
Peak load
energy
management
Control contact voltage
Connection cable, min. cross-section
Connection cable to be ordered separately.
Connection via a flexible supply lead with a separate
isolator is recommended. The isolator should be visible
and easily accessible after machine installation.
Vented
As relative humidity inside the vent ducting can be as high
as 100%, suitable measures must be taken to prevent a
backflow of condensate into the machine.
Installation plan: PT 8807 EL
Date: 2015-Sep-15
Page: 8
Air intake
Standard connection: Air intake from installation site
Unobstructed air intake into room recommended
(corresponding to 3 times the vent cross-section of
machine)
A sufficient supply of fresh air should be ensured to
replace the air extracted.
cm²
531
32 cu in
mm
mm
161
160
6 ½“
6 ¼“
Without base
2 × clamps
2 × screws DIN 571 (Ø × length)
2 × rawl plugs (Ø × length)
The machine should be bolted to the floor.
Fixing materials for a floating screed floor are to be
provided on site.
mm
mm
6 × 40
10 × 50
On concrete platform
2 × clamps
2 × screws DIN 571 (Ø × length)
2 × rawl plugs (Ø × length)
The machine must be bolted to the floor!
Fixing materials for a floating screed floor are to be
provided on site.
mm
mm
6 × 40
10 × 50
Unit width
Machine depth
Unit height
Casing width
Casing depth
mm
mm
mm
mm
mm
1.206
1.384
1.640
1.200
1.279
47 ½“
54 ½“
64 ½“
47 ¼“
50 ½“
Minimum width of delivery access to installation site
Recommended rear wall gap (measured to front of
machine)
Min. wall gap (to rear edge of lid)
mm
mm
1.220
1.800
48“
71“
mm
500
19 ¾“
Net weight
Max. load bearing in operation
Average heat dissipation
(dependent on ambient room temperature and program
selected)
A Noise level
A Sound pressure level
kg
N
Watt
287
3.708
973
632 lb
dB (A)
dB (A)
73,6
62
Alternative connection: Ducted air intake (from outside
building)
Connector on machine (int. diameter)
Connection pipe provided on site (ext. diameter)
Lid removal exposes live components! For safety
reasons, the pipe connected for central air intake should
be at least 900 mm long and secured using two screws.
Fittings
(supplied)
Machine data
Installation should only be carried out by authorised installers in accordance with all local and national regulations!
Follow installation instructions when installing machine. All rights reserved. Measurements in millimeters [inches].
Installation plan: PT 8807 EL
Date: 2015-Sep-15
Page: 9