Miele | 52718963USA | Installation Specifications 208 V | Miele 52718963USA Installation Specifications 208 V

Installation plan
Washer-dryer stack
PWT 6089 EL (Electrically Heated)
en - US
13.15
M.-Nr. 10 167 290 / 00
U.S.A.
Miele, Inc.
National Headquarters 9
Independence Way
Princeton, NJ 08540
Phone: 800-991-9380
609-419-9898
609-419-4241
Fax:
www.mieleusa.com
Technical Service & Support
Nationwide
Phone: 800-991-9380
Fax:
800-220-1348
proservice@mieleusa.com
2
PWT 6089 EL - measurements in inches
11 3/4"
27 1/4"
30"
50 3/4"
19 1/2"
52 5/8"
14 5/8"
76"
76"
20 7/8"
21 1/4"
27 1/4"
17 3/8"
11 3/4"
12 3/4"
15 1/8"
28 5/8"
27 1/2"
43 1/4"
27 1/2"
27 1/4"
30"
27 1/4"
43 1/4"
3
42 1/4"
< 39 3/8"
51 1/8"
51 1/8"
42 1/4"
< 39 3/8"
51 1/8"
PWT 6089 EL - measurements in inches
5 7/8"
43 1/4"
4
3/4"
76"
PWT 6089 EL - measurements in inches
17 3/8"
27 1/4"
24 3/4"
2"
22"
27 1/8"
43 1/4"
1 5/8"
14"
4"
1/4"
28"
5
PWT 6089 EL - measurements in millimeters
6
<
<
<
PWT 6089 EL - measurements in millimeters
7
PWT 6089 EL - measurements in millimeters
8
Technical datasheet
PWT 6089 LP (Drain pump)
Electric (EL)
Washer/Dryer stack:
Heating:
Legend:
Abbreviations in bold type:
Connection required
en - US
Abbreviations in circle with dashes:
Connection optional or required depending on model version
Options/accessoires:
Dispensing
pump
External dispensing pumps (2 or 4 head pump):
Voltage (external power supply required)
Fusing
Supplied with supply cable and plug
120V
15A
NEMA 5-15
Pump installation may only be performed by Miele Service.
Machine connections:
Electrical Standard voltage (2 AC 208V/220-240V 60Hz)
connection NOTE: Electrical connection depending on version ordered.
Washer (EL1) – 2 AC 208V/220-240V 60Hz
Voltage
Frequency
Rated load
Fuse rating
Length of supply lead
Supply lead with plug
V
Hz
kW
A
78“
2 AC 208 / 220-240
60
4 / 4.4 - 5.2
2 x 30
2000 mm
NEMA L6-30P
Dryer (EL2) – 2AC 208V 60Hz
Voltage
Frequency
Rated load
Fuse rating
Length of supply lead
Supply lead with plug
V
Hz
kW
A
78“
2 AC 208
60
4.84
2 x 30
2000 mm
NEMA L6-30P
Dryer (EL2) – 2AC 220-240V 60Hz
Voltage
Frequency
Rated load
Fuse rating
Length of supply lead
Supply lead with plug
V
Hz
kW
A
78“
2 AC 220-240
60
5.7
2 x 30
2000 mm
NEMA L6-30P
Electrical connection must be in full compliance with national regulations and
guidelines and with relevant local codes. Similarly, relevant regulations issued
by power utilities, occupational safety authorities and insurance companies as
well as good installation practices should be observed throughout.
Connection to the electrical supply should only be performed by qualified and
properly trained persons.
Connection using a multi-pole wall lockable socket(s) in compliance with
IEC/EN 60309 and IEC/EN 60947 is recommended in order to simplify electrical
tests. If machines are hard-wired, a multi-pole main switch must be provided on
site. Switches with a contact gap of more than 3 mm can be used. These
include switches, fuses and contactors (IEC/EN 60947). A wall socket or
electrical isolator must be easily accessible after installation.
Reinstallation of the supply point, changes to the equipment or checks on the
protective conductor, including determination of correct fuse rating, should only
be performed by a properly trained electrician.
If necessary, equipotential bonding must be provided in accordance with all
appropriate national and local regulations.
Technical datasheet: PWT 6089 EL
Date: Feb-2015
Page: 9
Electrical
isolator
Both washer-dryer stack connections must be disengaged by a common electrical disconnect device
that switches off all poles in accordance with IEC 60947-1 [Q1].
The electrical isolator [Q1] and plug connections [EL1, EL2] must be located in the immediate vicinity
of the machine. Both must be visible, accessible and within easy reach.
If the electrical isolator [Q1] is not in full view of a person performing maintenance work on the machine
at all times, the electrical isolator must be fitted with a lock.
Installation proposals:
-Electrical isolator before fusing-
-Electrical isolator behind fusing-
Technical datasheet: PWT 6089 EL
Date: Feb-2015
Page: 10
Cold water
(Soft water)
Min. flow pressure
Max. pressure
Max. throughput
On-site connection thread
Length of connection hose
(supplied: 1 connection hose)
14.5 psi
145 psi
2.9 gal/min
¾" external thread
61“
100 kPa
1000 kPa
11 l/min
¾" external thread
1550 mm
Hourly water demand (average for 60°C program) for
standard connection (with hot and cold water)
approx. 18.5 gal/h
approx. 70 l/h
158°F
14.5 psi
145 psi
2.9 gal/min
¾" external thread
61“
70°C
100 kPa
1000 kPa
11 l/min
¾" external thread
1550 mm
approx. 18.5 gal/hr
approx. 70 l/h
Max. temperature
Drain hose(int. diameter)
On-site hose connector for drain hose
(int. diameter x length)
158°F
7/8“
7/8“ x 1 3/16“
70°C
22 [DN 22] mm
22 × 30 mm
Max. transient throughput
Drain pump head height (from floor level)
6.9 l/min
39 3/8“
26 l/min
1000 mm
188 cfm
0.06 psi
176°F
4”
4”
320 m³/h
420 Pa
80°C
100 mm
100 mm
37 in2
237 cm²
1/4“ x 2“
5/16“ x 1 9/16“
6 × 50 mm
8 × 40 mm
If hot water supply is not available add hot water demand to
cold water demand.
Warm
water
(Soft water)
Max. temperature
Min. flow pressure
Max. pressure
Max. throughput
On-site connection thread
Length of connection hose
(supplied: 1 connection hose)
Hourly water demand (average for 140°F / 60°C program)
Machine can be connected to a hot water supply line with a
temperature of 158°F (70°C) to max.185°F (85°C). This
requires a separate inlet hose. This additional inlet hose is
available from Miele. The machine must also be
reprogrammed by Miele Service.
If hot water is not available, connect hot water hose to cold
water valve!
LP
Drain
pump
Vented drainage required. If ventilation is insufficient, Miele
installation kit, Mat. no. 05238090. Drain manifolds serving
several machines must be of sufficient cross-section.
Vented
Nominal air throughput in vented mode
Max. permissible pressure loss
Waste air/gas temperature, max.
Connector on machine (int. diameter)
Connection pipe provided on site (ext. diameter)
Miele adapter, Mat. no. 6595070 (int. diameter 100 mm) for
flexible aluminum ducting and adapter, Mat. no. 915051,
(ext. diameter 110 mm) for connection to standard heatresistant plastic pipes supplied.
As relative humidity inside the vent ducting can be as high
as 100%, suitable measures must be taken to prevent a
backflow of condensate into the machine.
Air intake
Standard connection:
=> Air intake from installation site
Min. air intake cross-section
(to prevent draughts in room)
A sufficient supply of fresh air should be ensured to replace
the air extracted.
Fittings
(supplied)
4 × clamps
4 × screws DIN 571 (Ø × length)
4 × rawl plugs (Ø × length)
Machine must be bolted to the floor!
Fixing materials for a floating screed floor are to be provided
on site.
Technical datasheet: PWT 6089 EL
Date: Feb-2015
Page: 11
Machine
data
Unit width
Unit depth
Unit height
Casing width
Casing depth
27 1/2“
30“
76“
27 1/4“
27 1/4“
700 mm
752 mm
1930 mm
692 mm
690 mm
Minimum width of delivery access to installation site
Recommended rear wall gap
Minimum rear wall gap
Recommended rear wall gap ensures sufficient space for
maintenance and servicing
28 3/8“
43 5/16“
35 7/16“
720 mm
1100 mm
900 mm
Net weight
Dynamic floor load, max.
Static floor load, max.
Dynamic load, max.
Drum frequency, max.
Average heat dissipation
(dependent on ambient room temperature and program
selected)
463 lbs
3600 N
2850 N
750 N
22 Hz
2830 BTU/hr
210 kg
3600 N
2850 N
750 N
22 Hz
0.83 kWh
Sound pressure (re 20 mPA), workplace-related
(at distance of 3’ 3” / 1 m and height of 5’3” / 1.6 m)
<70dB(A)
<70dB(A)
Installation should only be carried out by authorized installers in accordance with valid regulations!
Observe installation instructions when installing machine! All rights reserved!
Technical datasheet: PWT 6089 EL
Date: Feb-2015
Page: 12