Miele 52850705USA Installation Plan (Electric)

Miele 52850705USA Installation Plan (Electric)
Installation Plan
Tumble dryer
PT 8507 EL (Electrically heated)
en – US
37.15
M.-Nr. 09 883 200 / 02
U.S.A.
Miele, Inc.
National Headquarters
9 Independence Way
Princeton, NJ 08540
Phone: 800-991-9380
Fax:
609-419-4241
www.mieleusa.com
Technical Service & Support
Nationwide
Phone: 800-991-9380
Fax:
800-220-1348
[email protected]
It is essential to read the operating and installation instructions before
installing, commissioning or using the machine.
This avoids the risk of accidents or damage.
All rights reserved
M.-Nr. 09 883 200 / 02
2
Technical datasheet
Tumble dryer:
Heating:
PT 8507
Electric (EL)
Legend:
en - US
Abbreviations in bold type:
Connection required
Abbreviations in circle with dashes:
Connection optional or required depending on model version
Optional extras:
BS
Concrete base
Quality and density of concrete must comply with load.
Concrete base must be firmly secured to floor!
Recommended height
Minimum height
Minimum width
Minimum depth
4"
2"
47"
43"
100 mm
50 mm
1200 mm
1100 mm
Machine connections:
Electrical
connection
(Convertible)
Standard voltage
Frequency
Rated load
Fuse rating
Connection cable, min. cross-section
(Connection cable to be ordered separately)
Convertible to
Frequency
Rated load
Fuse rating
Connection cable, min. cross-section
(Connection cable to be ordered separately)
3 AC 220 - 240V
60 Hz
88775 104820 BTU/h
3 x 80 A
4 x AWG 6
3 AC 208V
60 Hz
78532 BTU/h
3 x 50 A
5 x AWG 6
26.0 – 30.7 kW
4 x 10 mm
23 kW
5 x 10 mm
Electrical connection must comply with national regulations.
Connection using multi-pole wall socket in compliance with IEC/EN 60309 and IEC/EN 60947 is
recommended in order to simplify electrical tests.
If machines are hard-wired, a multi-pole switch must be provided on site.
A wall socket or isolator must be accessible after installation.
Installation plan: PT 8507 EL
Date: 2015-Sep-07
Page: 8
Equipotential
bonding
Connection with male thread
Connection with washers and nut
3/8" x 1 3/8"
3/8"
10 mm x 35 mm
M 10
Accessories not included.
If necessary, equipotential bonding with good galvanic contact must be provided in accordance
with all appropriate national and local regulations.
Peak load
energy
management
Control contact voltage
Connection cable, min. cross-section
AC 230V
5 x AWG 14
5 x 1.5 mm
Connection cable to be ordered separately.
Connection via a flexible supply lead with a separate isolator is recommended.
The isolator should be visible and easily accessible after machine installation.
Air outlet
Max. nominal air flow in vented mode
Max. permissible pressure loss
Connection on machine side (ext. diameter)
Connection pipe provided on site (int. diameter)
Max. temperature
506.2 cfm
0.04 psi
5 7/8"
5 7/8"
176 °F
860 m³/h
300 Pa
150 mm
150 mm
80 °C
As relative humidity inside the vent ducting can be as high as 100%, suitable measures must be
taken to prevent a backflow of condensate into the machine.
Air intake
Standard connection: Air intake from installation site
Unobstructed air intake into room recommended (corresponding to 3 times the vent cross-section of machine)
A sufficient supply of fresh air should be ensured to
replace the air extracted.
82.3 in²
531 cm²
6 3/8"
6 1/4"
161 mm
160 mm
Without base
2 x clamps
2 x screws DIN 571 (Ø × length)
2 x rawl plugs (Ø × length)
The machine should be bolted to the floor.
Fixing materials for floor screed have to be provided on site.
1/4" x 1 5/8"
3/8" x 2"
6 mm x 40 mm
10 mm x 50 mm
On concrete platform
2 x clamps
2 x screws DIN 571 (Ø × length)
2 x rawl plugs (Ø × length)
Machine must be bolted to the platform!
Fixing materials for floor screed have to be provided on site.
1/4" x 1 5/8"
3/8" x 2"
6 mm x 40 mm
10 mm x 50 mm
Alternative connection: Ducted air intake (from outside
building)
Connector on machine (int. diameter)
Connection pipe provided on site (ext. diameter)
Lid removal exposes live components! For safety reasons,
the pipe connected for central air intake should be at least 35
7/16” [900 mm] long and secured with two screws.
Fittings
(supplied)
Installation plan: PT 8507 EL
Date: 2015-Sep-07
Page: 9
Machine data
Machine width
Machine depth
Machine height
Casing width
Casing depth
Minimum width of delivery access to installation site
Recommended rear wall gap (measured to front of machine)
Min. wall gap (to rear edge of lid)
Net weight
Dynamic floor load, max.
Average heat dissipation
(depends on ambient room temperature and selected
program)
Noise level
Sound pressure level
(measured at a distance of 39 3/8” from the machine and at a
height of 63”)
47 1/2"
40 1/8"
64 5/8"
47 1/4"
36"
40 1/2"
63"
19 3/4"
524.7 lbs
607.7 lbf
2763.8 BTU
1206 mm
1018 mm
1640 mm
1200 mm
913 mm
1030 mm
1600 mm
500 mm
238 kg
2703 N
810 W
72.2 dB (A)
60 dB (A)
Installation should only be carried out by authorised installers in accordance with all local and national regulations!
Follow installation instructions when installing machine. All rights reserved.
Installation plan: PT 8507 EL
Date: 2015-Sep-07
Page: 10