U-Line | U-3036BVWCINT-00B | Quick Start Guide | U-Line U-3024RGLS-15B Quick Start Guide

U-Line U-3024RGLS-15B Quick Start Guide
QUICK START GUIDE
Modular 3000 Series
•
115 V / 60 Hz
QUICK START GUIDE
u-line.com
WELCOME TO U-LINE
Congratulations on your U-Line purchase. Your product comes from a company with over five decades and three generations
of premium modular ice making, refrigeration, and wine preservation experience. U-Line continues to be the American
leader, delivering versatility and flexibility for multiple applications including residential, light commercial, outdoor and marine
use. U-Line’s complete product collection includes modular Wine Captain® Models, Beverage Centers, Clear Ice Machines,
Crescent Ice Makers, Glass & Solid Door Refrigerators, Drawer Models, Freezers, and Combo® Models.
U-Line has captivated those with an appreciation for the finer things with exceptional functionality, style, inspired innovations
and attention to even the smallest details. We are known and respected for our unwavering dedication to product design,
quality and selection. U-Line is headquartered in Milwaukee, Wisconsin with a west coast office located in Laguna Beach,
California and European support in Dublin, Ireland. U-Line has shipped product to five continents for over two decades and is
proud to have the opportunity to ship to you.
PRODUCT INFORMATION
Looking for additional information on your product? User Guides, Quick Reference Guides, CAD Drawings, Compliance
Documentation, and Product Warranty information are all available for reference and download at u-line.com under
Documentation.
PROPERTY DAMAGE / INJURY CONCERNS
In the unlikely event property damage or personal injury is suspected related to a U-Line product, please take the following
steps:
1. U-Line Customer Care must be contacted immediately at +1.800.779.2547.
2. Service or repairs performed on the unit without prior written approval from U-Line is not permitted. If the unit has been
altered or repaired in the field without prior written approval from U-Line, claims will not be eligible.
SERVICE INFORMATION
Answers to Customer Frequently Asked Questions are available at u-line.com under Customer Care or you may contact our
Customer Care group directly, contact information below.
GENERAL INQUIRIES
SERVICE & PARTS ASSISTANCE
U-Line Corporation
Monday - Friday 8:00 am to 5:30 pm CST
8900 N. 55th Street
T: +1.800.779.2547
Milwaukee, Wisconsin 53223 USA
F: +1.414.354.5696
Monday - Friday 8:00 am to 4:30 pm CST
Service Email: onlineservice@u-line.com
T: +1.414.354.0300
Parts Email: onlineparts@u-line.com
F: +1.414.354.7905
Email: sales@u-line.com
u-line.com
CONNECT WITH US
Designed, engineered and assembled in WI, USA
QUICK START GUIDE
Contents
1
Model List
3
Safety and Warning
4
Environmental Requirements
4
Electrical
5
Door Swing
6
General Installation
6
Integrated Panel Installation
9
Control Quick Guide
10
First Use
10
Sabbath Mode
11
Warranty
u-line.com
QUICK START GUIDE
u-line.com
Model List
This guide provides the basics to get you started. Looking for more information? Visit u-line.com to view detailed User Guides
for all U-Line products.
Wine Captain® Models*
U-3018WCS-00B
U-3024ZWCS-00B
U-3036WCWCS-00B
U-3018WCS-13B
U-3024ZWCS-13B
U-3036WCWCS-13B
U-3018WCS-15B
U-3024ZWCS-15B
U-3036WCWCINT-00B
U-3018WCINT-00B
U-3024ZWCINT-00B
U-3036WCWCINT-60B
U-3018WCINT-60B
U-3024ZWCINT-60B
Beverage Centers*
U-3024BEVS-00B
U-3036BVWCS-00B
U-3024BEVS-13B
U-3036BVWCS-13B
U-3024BEVS-15B
U-3036BVWCINT-00B
U-3024BEVINT-00B
U-3036BVWCINT-60B
U-3024BEVINT-60B
U-3024BEVINT-61B
Glass Door Refrigerators*
U-3018RGLS-00B
U-3024RGLS-00B
U-3036RRGLS-00B
U-3018RGLS-13B
U-3024RGLS-13B
U-3036RRGLS-13B
U-3018RGLS-15B
U-3024RGLS-15B
U-3036RRGLINT-00B
U-3018RGLINT-00B
U-3024RGLINT-00B
1
QUICK START GUIDE
u-line.com
Solid Door Refrigerators*
U-3018RS-00B
U-3024RS-00B
U-3036RRS-00B
U-3018RINT-00B
U-3024RINT-00B
U-3036RRINT-00B
Refrigerator Drawers*
U-3024DWRINT-00B
U-3024DWRS-00B
Freezers*
U-3024FZRS-00B
U-3024FZRINT-00B
*Unit shown with wood panel not included with unit.
Visit http://www.u-line.com/product-literature/userguides or
scan this QR code to view all user guides online.
2
QUICK START GUIDE
u-line.com
Safety and Warning
! DANGER
NOTICE
This unit contains R600a (Isobutane) which is a
Please read all instructions before installing,
flammable hydrocarbon. It is safe for regular
operating, or servicing the appliance.
use. Do not use sharp objects to expedite
defrosting. Do not service without consulting the
Use this appliance for its intended purpose only and follow
“R600a specifications” section included in the
these general precautions with those listed throughout this
User Guide. Do not damage the refrigerant
guide:
circuit.
SAFETY ALERT DEFINITIONS
! WARNING
Throughout this guide are safety items labeled with a
Danger, Warning or Caution based on the risk type:
Service must be done by factory authorized
service personnel. Any parts shall be replaced
with like components. Failure to comply could
! DANGER
increase the risk of possible ignition due to
incorrect parts or improper service.
Danger means that failure to follow this safety
statement will result in severe personal injury or
death.
! WARNING
Warning means that failure to follow this safety
statement could result in serious personal injury
or death.
! CAUTION
Caution means that failure to follow this safety
statement may result in minor or moderate
personal injury, property or equipment damage.
3
QUICK START GUIDE
u-line.com
Environmental Requirements
Electrical
This model is intended for indoor/interior applications only
! WARNING
and is not to be used in installations that are open/
exposed to natural elements.
SHOCK HAZARD — Electrical Grounding
Required. Never attempt to repair or perform
This unit is designed to operate between 50°F (10°C) and
maintenance on the unit until the electricity has
100°F (38°C). Higher ambient temperatures may reduce
been disconnected.
the unit’s ability to reach low temperatures and/or reduce
ice production on applicable models.
Never remove the round grounding prong from
the plug and never use a two-prong grounding
For best performance, keep the unit out of direct sunlight
adapter.
and away from heat generating equipment.
Altering, cutting or removing power cord,
In climates where high humidity and dew points are
removing power plug, or direct wiring can cause
present, condensation may appear on outside surfaces.
serious injury, fire, loss of property and/or life,
This is considered normal. The condensation will
and will void the warranty.
evaporate when the humidity drops.
Never use an extension cord to connect power to
the unit.
! CAUTION
Always keep your working area dry.
Damages caused by ambient temperatures of
40°F (4°C) or below are not covered by the
warranty.
NOTICE
Electrical installation must observe all state and
local codes. This unit requires connection to a
grounded (three-prong), polarized receptacle
that has been placed by a qualified electrician.
The unit requires a grounded and polarized 115 VAC,
60 Hz, 15A power supply (normal household current). An
individual, properly grounded branch circuit or circuit
breaker is recommended. A GFCI (ground fault circuit
interrupter) is usually not required for fixed location
appliances and is not recommended for your unit because
it could be prone to nuisance tripping. However, be sure
to consult your local codes.
4
QUICK START GUIDE
u-line.com
Door Swing
Wall
For Integrated models that are installed adjacent to a wall,
1/4" (6 mm)
1/4" (6 mm) clearance is recommended from wall on
hinge side to allow the door to open 90°. Allow for
additional space for any knobs or pulls installed on the
integrated panel/frame.
Stainless Steel models that are installed adjacent to a wall
require 2-1/4" (57 mm) door clearance on hinge side to
allow for door handle.
Units have a zero clearance when installed adjacent to
90°
Door Swing
cabinets.
Space Required
For any Knobs or Pulls
Integrated
2-1/4" MIN
(57 mm MIN)
Wall
90°
Door Swing
Stainless
5
QUICK START GUIDE
u-line.com
General Installation
INSTALLATION
1. Plug in the power/electrical cord.
LEVELING INFORMATION
1. Use a level to confirm
2. Gently push the unit into position. Be careful not to
the unit is level. Level
entangle the cord.
should be placed along
top edge and side
edge as shown.
3. Re-check the leveling, from front to back and side to
1
side. Make any necessary adjustments. The unit’s top
surface should be approximately 1/8" (3 mm) below
2. If the unit is not level,
the countertop.
remove grille and
adjust legs as
2
necessary. Use
4. Install the anti-tip bracket.
included tool to adjust
the height of the rear legs.
5. Remove the interior packing material and wipe out the
inside of the unit with a clean, water-dampened cloth.
Integrated Panel Installation
ALL 3000 SERIES EXCEPT DWR
1. Fully open door.
Rotate Front Legs to Adjust
Rotate Clockwise to raise rear leg.
Rotate Counter-Clockwise to lower leg.
2. Starting at corner, pull
gasket away from door.
3. Confirm the unit is level after each adjustment and
repeat the previous steps until the unit is level.
3. Continue to pull gasket
free from gasket channel.
INSTALLATION TIP
If the room floor is higher than the floor in the cutout
4. Upon removal, lay gasket down on a flat surface.
opening, adjust the rear legs to achieve a total unit rear
height of 1/8" (3 mm) less than the opening’s rear height.
Shorten the unit height in the front by adjusting the front
legs. This allows the unit to be gently tipped into the
opening. Adjust the front legs to level the unit after it is
correctly positioned in the opening.
6
QUICK START GUIDE
u-line.com
5. The panel should be aligned with the outside edge
NOTICE
(opposite the hinge) and high enough to align with the
It is important to ensure that all drilled holes are
highest point in the door.
drilled to the correct depth in order to avoid
splits in the wood when hardwood is installed.
Align Top Of Panel With Highest Point Of Door
8. Locate 6 of the #6x 1-1/2" (38 mm) screws provided
with your unit.
Align Panel
Against
Door Edge
First
9. Using a Phillips screwdriver, place one screw into each
of the 6 pilot holes and screw down. Do not overtighten
screws.
10.Ensure the screws sit flush against the bottom of the
NOTICE
channel.
Due to differences in floor construction or
surrounding cabinetry, the panel may not sit
flush with the top of the door.
6. Secure integrated
panel to door using
Integrated Panel
Bar
Clamp
Integrated Panel
clamps. A robust
tape may also be
11.Remove clamps from door.
used. U-Line
recommends the
use of bar clamps
to secure the panel
to the door. If using
tape, be certain the
NOTICE
Door/Drawer
If panel requires additional adjustment after
removing clamps, slightly loosen each screw and
Wood
Panel
adjust panel as necessary. Tighten screws upon
completion.
tape will not
damage panel finish
upon removal.
12.Starting at the corners, re-install the gasket into the
gasket channel in the frame. Make sure the gasket is
7. Using a 7/64"
(3 mm) drill bit, drill
fully seated.
Bar
Clamp
6 pilot holes into
the wood panel 1/2"
(12 mm) deep using
the holes in the
door frame as a
guide.
7
QUICK START GUIDE
u-line.com
3000 SERIES DWR
NOTICE
1. Fully open drawer.
It is important to ensure that all drilled holes are
drilled to the correct depth in order to avoid
splits in the wood when hardwood is installed.
2. The panel should be aligned with the outside edge and
high enough to align with the highest point in the
drawer.
5. Locate 12 of the #6x 1-1/2" (38 mm) screws provided
with your unit.
Align Top Of Panel With Highest Point Of Drawer
6. Using a Phillips screwdriver, place one screw into each
of the 6 pilot holes and screw down. Do not overtighten
screws.
Align Panel
Against
Drawer Edge
First
Integrated Panel
Integrated Panel
NOTICE
Due to differences in floor construction or
7. Remove clamps from drawer.
surrounding cabinetry, the panel may not sit
flush with the top of the drawer.
NOTICE
3. Secure integrated
panel to drawer
If panel requires additional adjustment after
Bar
Clamp
removing clamps, slightly loosen each screw and
using clamps. A
adjust panel as necessary. Tighten screws upon
robust tape may
completion.
also be used. ULine recommends
the use of bar
clamps to secure
the panel to the
drawer. If using
Door/Drawer
Wood
Panel
tape, be certain the
tape will not
damage panel finish
upon removal.
4. Using a 7/64"
Bar
Clamp
(3 mm) drill bit, drill
6 pilot holes into
the wood panel 1/2"
(12 mm) deep using
the holes in the drawer frame as a guide.
8
QUICK START GUIDE
u-line.com
Control Quick Guide
Actual Display: 3018R, 3018RGL and 3024R, 3024RGL,
3024BEV
Actual Display: 3018WC
Up
Up
Select
Select
Beverage
38°F
Red Wine
55°F
Down
Down
Can be displayed in Celsius
Power
U-Select Lighting
Can be displayed in Celsius
Power
U-Select Lighting
Actual Display: 3024DWR
Actual Display: 3024ZWC
Up
Up
Red Wine
55°F
Down
Zone Indicator
Zone Toggle
Zone Indicator
Select
Zone Indicator
Zone Toggle
Zone Indicator
Select
Beverage
38°F
White Wine
5O°F
Down
Can be displayed in Celsius
Power
U-Select Lighting
Market
38°F
Can be displayed in Celsius
Power
U-Select Lighting
Actual Display: 3024FZR
Actual Display: 3036WCWC, 3036BVWC, 3036RR,
Up
3036RRGL
Up
Zone Indicator
Zone Toggle
Zone Indicator
Select
Red Wine
55°F
Down
Select
Polar
0°F
White Wine
5O°F
Down
Can be displayed in Celsius
Power
U-Select Lighting
Can be displayed in Celsius
Power
U-Select Lighting
Control Function Guide:
FUNCTION
COMMAND
DISPLAY/OPTIONS
OFF
Press
and hold
Display will count down from 5 to off
ON
Press
and release
Unit will come on immediately
Adjust mode
Press
to select zone
Press
or
Adjust temperature
Adjust lighting
Light ON/OFF with door
Press
Modes available in table below.
and release to select zone
(dual zone only)
Press
Press
and release to scroll through the modes.
Press
or
and release. When the “F” or “C”
in the display is flashing, press
or
adjust the set point temperature.
to adjust lighting
to have light ON/OFF with door
Press
to select zone
Press
or
Press
and release to scroll through timer
to set low, medium or high
settings. Both zones will default to the same timer
setting.
Customer menu
Press
to
and hold for 5 seconds
Press
9
or
to scroll through menu
QUICK START GUIDE
Mode
Set Point Temperature Range
°F (°C)
°F (°C)
Red Wine
55 (12)
55-65 (12-18)
White Wine
50 (10)
45-55 (7-12)
Sparkling Wine
45 (7)
38-50 (3-10)
Deli
36 (2)
34-40 (1-4)
Beverage/Drinks
38 (3)
34-65 (1-18)
Market/Fresh
38 (3)
34-40 (1-4)
Root
50 (10)
45-55 (7-12)
Pantry
42 (5)
34-70 (1-21)
Polar
0 (-18)
(-5)-5 ([-21]-[-15])
u-line.com
Sabbath Mode
Up
Select
RETURN TO MENU
SABBATH MODE
OFF?
Down
This unit offers a Sabbath mode for users who require this
functionality during Sabbaths. Sabbath mode disables
system responses to user initiated activities and all
external functions, including lighting, display and audible
First Use
alarms. The unit will still maintain internal temperatures
and set points.
All U-Line controls are preset at the factory. Initial startup
requires no adjustments.
To enable Sabbath Mode:
NOTICE
1. Open the unit’s door to activate the display.
U-Line recommends allowing the unit to run
overnight before loading with product.
2. To access the Customer Menu, hold
for 5 seconds.
When plugged in, the unit will begin operating under the
factory default setting. Follow the on screen prompt for
3. Press
language selection and temperature units.
To turn the unit off, press
or
to scroll through available selections.
4. Select Sabbath Mode from the Customer Menu by
and hold for 5 seconds and
pressing
release. The display will show a countdown to switching
.
the unit off.
5. Press
To power your unit on, simply press
to select “Off”.
and the unit will
immediately switch on.
6. Press
10
. “Off” will begin to flash.
QUICK START GUIDE
7. Press
or
u-line.com
transportation charges for replacements under this
to change “Off” to “On”.
warranty and labor costs not specifically covered by
8. Press
this warranty, shall be the responsibility of the
to confirm your selection.
purchaser. This warranty extends only to the original
purchaser of the U-Line product. The Product
The Display will fade out as the unit enters Sabbath Mode.
Registration Card included with the product should be
Sabbath
promptly completed by you and mailed back to U-Line,
or you can register on-line at www.u-line.com.
Mode remains active until
is quickly pressed and
3. The warranty listed above does not apply to floor
released.
display models. The warranty for these models shall
be one year from the date installation. This one-year
warranty does not apply to cosmetic damages. A proof
Warranty
of purchase may be required.
U-LINE CORPORATION LIMITED WARRANTY
4. The following conditions are excluded from this limited
1. U-Line Corporation (“U-Line”) warrants each U-Line
warranty: use of cleaners other than the recommended
product to be free from defects in materials and
stainless steel cleaners and U-Line Clear Ice Maker
workmanship for a period of one year (two years on
cleaner; installation charges; damages caused by
Modular 3000 Series) from the date of installation.
disasters or acts of God, such as fire, floods, wind, and
U-Line further warrants the sealed system (consisting
lightning; damages incurred or resulting from shipping,
of the compressor, condenser, evaporator, hot gas
improper installation, unauthorized modification, or
bypass valve, dryer, and connecting tube) in each
misuse/abuse of the product; customer education
U-Line product to be free from defects in materials and
calls; food loss and spoilage; door and water level
workmanship for a period of five years from the date of
adjustments (except during the first 30 days from the
installation.
date of installation); defrosting the product; adjusting
the controls; door reversal; and cleaning the
2. During the initial one-year warranty period (two years
condenser.
on Modular 3000 Series) for all U-Line products U-Line
shall: (1) repair any product or replace any part of a
5. U-Line products are designed to operate in ambient
product; and (2) for all Marine, RV, and Domestic
temperatures between 50°F and 100°F unless
U-Line products sold and serviced in the United States
otherwise noted in the product manual. Exposure to
(including Alaska and Hawaii) and Canada, U-Line
temperatures outside this range may cause
shall be responsible for the labor costs performed by a
degradation of performance and issues, such as lower
U-Line authorized service company, incurred in
ice production or spoiled contents, that are not
connection with the replacement of any defective part.
covered under the terms of this warranty as a result of
During years two through five of the warranty period
that exposure. U-Line product may not be subjected to
for the sealed system, U-Line shall: (1) at U-Line’s
temperatures below 40°F without following the
option repair or replace any part of the sealed system;
winterization and vacation shutdown procedures in the
and (2) for all Marine, RV, and Domestic U-Line
user guide.
products sold and serviced in the United States
(including Alaska and Hawaii) and Canada, U-Line shall
6. U-Line’s Outdoor Limited Warranty, set forth in this
be responsible for the labor costs incurred in
connection with the replacement of any defective part
Paragraph 6 shall apply to U-Line models deemed
of the sealed system. All other charges, including
suitable for outdoor use by Underwriters Laboratory
11
QUICK START GUIDE
u-line.com
(“UL”) as noted in the U-Line Product Catalog, U-Line’s
website, and/or on the serial tag located inside the
product. Outdoor product may come into contact with
rain by virtue of outdoor use. Exposure to other
sources of water shall also cause this warranty to be
void, including flooding of the area in proximity of the
unit greater than 1/8" deep in water, hurricanes,
splashing of pool water, or directing a spray from a
hose or similar device into and around the unit.
7. If a product defect is discovered during the applicable
warranty period, you must promptly notify U-Line at
1-800-779-2547 or the dealer from whom you
purchased the product. In no event shall such
notification be received later than 30 days after the
expiration of the applicable warranty period. U-Line
may require that defective parts be returned, at your
expense, to U-Line’s factory in Milwaukee, Wisconsin,
for inspection. Any action by you for breach of
warranty must be commenced within one year after
the applicable warranty period.
8. THIS LIMITED WARRANTY IS IN LIEU OF ANY AND ALL
OTHER WARRANTIES, EXPRESS OR IMPLIED,
INCLUDING ANY IMPLIED WARRANTY OF
MERCHANTABILITY OR IMPLIED WARRANTY OF
FITNESS FOR A PARTICULAR PURPOSE, ALL OF WHICH
ARE DISCLAIMED. U-Line’s sole liability, and your
exclusive remedy, under this warranty is set forth in
the paragraphs above. U-Line shall have no liability
whatsoever for any incidental, consequential, or
special damages arising from the sale, use, or
installation of the product or from any other cause
whatsoever, whether based on warranty (express or
implied) or otherwise based on contract, tort, or any
other theory of liability.
9. Some states do not allow limitations on how long an
implied warranty lasts or the exclusion or limitation of
incidental or consequential damages, so the above
limitations may not apply to you. This warranty gives
you specific legal rights, and you may also have other
rights which vary from state to state.
Copyright © 2016 U-Line Corporation. All Rights Reserved.
Publication Number 30445 8/2016 Rev.A
12
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project