GE Monogram ZV30RSFSS, ZV30SSFSS, ZV36TSFSS, GEZV48TSFSS, GEZV36SSFSS, GEZV36RSFSS, ZV30TSFSS, GEZV48SSFSS, GEZV42ISHSS User manual

GE Monogram ZV30RSFSS, ZV30SSFSS, ZV36TSFSS, GEZV48TSFSS, GEZV36SSFSS, GEZV36RSFSS, ZV30TSFSS, GEZV48SSFSS, GEZV42ISHSS User manual
Professional hoods
ON/OFF
48", 36" and 30"
tapered-sided
hoods
ZV48TSFSS
48", 36" and 30"
straight-sided
hoods
ZV48SSFSS
ZV30HSRSS
30" undercabinet
hood
ZV48RSFSS, ZV36RSFSS and
ZV30RSFSS
ZV48TSFSS, ZV36TSFSS and
ZV30TSFSS
ZV48SSFSS, ZV36SSFSS and
ZV30SSFSS
ZV30HSRSS
Overall dimensions
(WxHxD in inches):
48 x 22-1/2 x 25
36 x 22-1/2 x 25
30 x 22-1/2 x 25
Amps @ 110 Volts 12.4/6.4/6.4
Approx. shipping
wt. (lbs.)
130/110/100
Overall dimensions
(WxHxD in inches):
48 x 18 x 25
36 x 18 x 25
30 x 18 x 25
Amps @ 110 Volts 12.4/6.4/6.4
Approx. shipping
wt. (lbs.)
130/110/100
Overall dimensions
(WxHxD in inches):
48 x 18 x 25
36 x 18 x 25
30 x 18 x 25
Amps @ 110 Volts 12.4/6.4/6.4
Approx. shipping
wt. (lbs.)
130/110/100
Overall dimensions
(WxHxD in inches):
30 x 10-1/2 x 25
Amps @ 120 Volts
Approx. shipping
wt. (lbs.)
• 10" round exhaust duct
• Exhaust damper
• Snap-in blower assembly
• 6" and 12" standard or
full-width stackable duct
covers (order separately)
• Stainless steel backsplash
included
• Warming shelf included
• 10" round exhaust duct
• Exhaust damper
• Snap-in blower assembly
• 6" and 12" standard-width
stackable duct covers (order
separately)
• 10" round exhaust duct
• Exhaust damper
• Snap-in blower assembly
• 6" and 12" standard- or
full-width stackable duct
covers (order separately)
• 8" round exhaust duct
• 3-1/2" louvered or
non-louvered riser (included)
• Recirculating option will
require the use of the 3-1/2"
louvered riser.
48", 36" and 30"
restaurant-style hoods
ZV48RSFSS
3.3
90
General features
Professional styling. Crafted of premium-grade stainless steel, with every edge buffed by hand,
Monogram® Professional hoods make a compelling statement of quality and refinement.
Powerful ventilation. A powerful centrifugal blower and variable-speed control keep your kitchen
free of fumes and excess heat.
Infrared warming lamps. Powerful infrared lamps on wall-mounted hoods cast a warm glow over
the cooking surface, while generating the heat necessary to keep baked goods at ready-to-serve
temperatures.
Brilliant task lighting. Halogen lights illuminate the cooktop surface below and can be adjusted to
complement the dining occasion.
Removable filters. During ventilation, stainless steel filters trap airborne grease particles, and can
be easily removed for safe cleaning in your dishwasher.
For additional details on product installation, warranty coverage, care and maintenance, visit
monogram.com.
54" and 42"
island hoods
ZV54ISHSS and ZV42ISHSS
Overall dimensions
(WxHxD in inches):
54 x 24 x 36-1/4
42 x 20 x 31-1/2
Amps @ 120 Volts
Approx. shipping
wt. (lbs.)
10.4/9.5
210/170
• 10" round exhaust duct
• 8' ceiling duct cover and
support (included)
• Optional 9'–10' ceiling duct
cover and support available
56
monogram.com
Professional vent hoods
Ductwork planning
Restaurant-style, tapered- and straight-sided hoods
Select a Professional hood with straight or tapered sides, or a
dramatic restaurant-style hood to match the width of the range,
rangetop or cooktop. All Professional hoods are available in 48",
36" and 30" widths.
Restaurant-style, tapered- and straight-sided hoods
These vent hoods are equipped for 10" round ductwork. For best
performance, use 10" round ductwork on the 48"-wide hoods.
36" and 30" hoods may be transitioned to 8" round.
• Hoods may be vented vertically through upper cabinets, soffit
or ceiling. The blower outlet is 8-1/8" x 8". A duct transition to
10" round with damper is supplied for vertical exhaust. Use
locally supplied elbows to vent horizontally.
• Use metal ductwork only.
Under-cabinet hoods
These vent hoods are designed to be installed onto a wall or
beneath a soffit or cabinet.
• For satisfactory performance, duct run should not exceed 150
feet equivalent length for any duct configuration. Refer
to the duct fittings chart in the installation instructions.
• Install these hoods 24" minimum to 36" maximum above the
cooking surface.
• Install a wall cap or roof cap with damper at the exterior
opening. Order the wall or roof cap and any transition needed
in advance.
Island hoods
Both models are shipped with a support frame and duct cover
for ceiling heights of 7'11" up to 8'5".
• Accessories are available to reach ceiling heights from
8'6" to 10'4". These accessories include telescoping support
frames and decorative covers.
• Optional accessories must be ordered with the hood and be
on-site before final framing and wall finishing.
• A mounting template is provided with each hood to help
accurately locate the hood above the cooking surface and to
locate the mounting frame and screws.
• For a finished appearance, a top cover is supplied with both
hoods. Install the top cover whenever the top of the hood will
be visible.
Structural suppor t
Restaurant-style, tapered- and straight-sided hoods
All Professional hoods weigh over 100 pounds; therefore adequate
structural support must be provided. Hoods must be secured to
vertical studs or to studs in the soffit.
• It is strongly recommended that the vent hood and duct
cover(s) if used, be on-site before final framing and wall
finishing. This will help to accurately locate the ductwork
and electrical service.
• Final installation will be much easier if the hood is installed
before the range, rangetop or cooktop underneath.
Island hoods
These vent hoods are heavy. Adequate structural support must
be provided. The ceiling structure must be capable of supporting
the weight of the hood and any inadvertent user contact loads
(approximately 300 lbs.).
Under-cabinet hoods
• This vent hood is designed to be installed beneath a cabinet
or beneath a cabinet mounted to a soffit.
Custom hood inser ts
This vent hood can be installed over any 30" Monogram
Professional rangetops or ranges.
Professional hoods
• Plan the shortest and straightest route for venting exhaust to
the outdoors.
• This hood is designed for 8" round ducting. The 8" round duct
can transition to 3-1/4" x 10" or 3-1/4" x 12".
• Recirculating option requires the use of 3-1/2" louvered riser.
• Plan the route for venting exhaust to the outdoors
considering any transitions you may require.
• Use locally supplied ducting to vent horizontally through the
rear wall or vertically through the ceiling.
• Use the shortest and straightest duct route possible. For
satisfactory performance, duct run should not exceed 100'
equivalent length for any duct configurations.
te l e s c o p i c
d o w n d r a f t v e nt s
• All models can be installed onto a wall or beneath a soffit.
Decorative duct covers are available for all models. The duct
cover conceals the ductwork running from the top of the hood
to the ceiling or soffit. Duct covers are available in 6" or 12"
heights. Stack one or more duct covers to reach your ceiling
height.
chimney hoods
Advance planning for professional hoods
• Refer to “Duct Fittings” chart to compute the maximum
permissible length for duct runs to the outdoors.
• Install a wall or roof cap with damper at the exterior opening.
Order the wall or roof cap and any transition and length of
duct needed in advance from a local hardware store.
• Determine the exact location of the vent hood.
• Wall or ceiling duct must be projected out at least 1" for duct
connection.
• For better air flow results, use rigid metal ductwork.
Ductwork planning for recirculation mode
All parts are included to install in recirculation mode.
Mounting for adequate support
• The hood must be secured to vertical studs in the wall. See
the Wall or Ceiling and Cabinet Preparation section for vented
or recirculation installation.
• We strongly recommend that the vent hood be on-site to
accurately locate the ductwork and electrical service.
• Installation will be easier if the vent hood is installed before
the cooktop and countertop are installed.
57
Advance planning for professional hoods
to the rear knockout and junction box.
Island hoods
These vent hoods are equipped for 10" round rigid metal duct.
Maximum equivalent duct length is 150 ft. Install a roof cap
with damper at the exterior opening.
• T he exact location for the house wiring depends on the
installation height and size of the hood. See installation
instructions for details.
Electrical requirements
• On wall-mounted hoods, the junction box is fastened to the
back of the hood on the right side. If necessary, the junction
box can be relocated to the top of the hood.
These vent hoods must be supplied with 120V, 60Hz, and
connected to an individual, properly grounded branch circuit
protected by a 15- or 20-amp circuit breaker or time-delay fuse.
• On island hoods, the junction box is located on the top of the
hood and is concealed by ductwork.
• On wall-mounted hoods, the back side is recessed, providing
a large area for the house wiring to exit the wall and be routed
Restaurant-style hood dimensions
12"
12"
47-15/16"
12"
35-15/16"
10"
10"
22-1/2"
22-1/2"
25"
47-15/16"
29-15/16"
22-1/2"
35-15/16"
25"
ZV48RSFSS
10"
29-15/16"
25"
ZV36RSFSS
ZV30RSFSS
Straight-sided hood dimensions
12"
12"
605Dia138
18"
12"
605Dia140
605Dia139
47-15/16"
35-15/16"
18"
25"
47-15/16"
18"
25"
35-15/16"
ZV48SSFSS
Tapered-sided hood dimensions
605Dia132
12"
40"
29-15/16"
25"
ZV36SSFSS
Under- cabinet hood dimensions
605Dia133
12"
30"
29-15/16"
ZV30SSFSS
605Dia136
3-1/2"
18"
10-1/2"
25"
12"
47-15/16"
ZV48TSFSS
717Dia5
18"
ZV30HSRSS
with louvered riser
28"
Island hood dimensions
14"
16"
25-3/4"
33"
9"*
5"*
25"
35-15/16"
ZV36TSFSS
12"
22"
20"
24"
717Dia6
18"
36-1/4"
25"
58
29-15/16"
ZV30TSFSS
54"
Model ZV54ISHSS supplied duct cover
*5" for ceiling 20-1/4"W
heights of 7’11"
to 8’5"
dimensions:
x 12"D
x 5"H
using the supplied support frame and duct cover
31-3/4"
42"
*9" for ceiling heights of 7'11" to 8'5" using the
supplied support frame and duct cover
*9" for ceiling heights of 7’11" to 8’5"
Model
supplied
duct
usingZV42ISHSS
the supplied support
frame
andcover
duct cover
dimensions: 16"W x 12"D x 9"H
monogram.com
Advance planning for professional hoods
Restaurant-style hoods
Determine bottom of hood location (Dim. A) by subtracting
12-1/2" from the desired installation height.
Note: Exact installation height
is affected by the use of the
supplied warming shelf and
by the use of duct covers.
chimney hoods
Installation height requirements
Under-cabinet hood
This vent hood can be installed for vented or recirculating
operation. It can be installed over a Monogram® 30" gas,
digital or induction cooktop, and 30" Monogram Professional
range. Installation height should measured as shown below.
Installation
Height
30" Min.
36" Max.
32" Min.
38" Max.
24" Min.
36" Max.
Note: Clearances may vary due to type of cooking product
and local codes. Check with local inspectors to be sure
standard is applicable.
Custom hood inser ts
Restaurant-style hoods are supplied with a stainless steel
backsplash and a warming shelf. Install the hood with or
without either. Clearances to the cooking605Dia141
surface will vary
depending upon use of the warming shelf.
Professional hoods
Dim. A
Note: Installation height should be measured from the
cooking surface to the lowest part of the hood.
Installation with supplied
warming shelf
Install the hood 32"
minimum to 38" maximum
above any type cooking
surface when the warming
shelf is used.
8 ft. Ceiling
605Dia137
If you are installing the hood above a gas or electric drop-in
style cooktop, the hood may be installed as low as 24" above
the cooking surface.
Tapered- and straight-sided hoods
Install these vent hoods 30" minimum to 36" maximum
above the cooking surface of any Professional range or
rangetop. If you intend to install the hood above a gas or
electric drop-in style cooktop, the hood may be installed as
low as 24" above the cooking surface.
Note: Exact installation height
may be determined by use of
one or more duct covers.
8 ft. Ceiling
9" Supplied
Duct Cover
5" Supplied
Duct Cover
31"
31"
ZV42I
ZV54I
te l e s c o p i c
d o w n d r a f t v e nt s
Installation without
warming shelf
Install these vent hoods 30"
minimum to 36" maximum
above the cooking surface of
any Professional-style range
or rangetop.
Island hoods
These vent hoods must be installed 30" minimum to 36"
maximum above the cooking surface—regardless of ceiling
height. Therefore, installation height of the hood depends
on the exact ceiling height of the kitchen.
Example: Hood installation height with 8' ceilings.
• If the ceiling height is 7'11", the hood installation height
above the cooking surface will be 30".
• If the ceiling height is 8'5", the hood installation height
above the cooking surface will be 36".
30" MIN.
36" MAX.
59
605Dia129
Advance planning for professional hoods
Duct Cover(s)
10" Hood
Height
Duct cover accessories
Standard duct covers
Standard duct covers are for Professional restaurant-style,
tapered- and straight-sided hoods. Available in 6" and 12"
heights, duct covers may be stacked in various combinations
to conceal the ductwork running from the top of the hood.
To avoid unsightly gaps above the hood, plan the hood
installation height with consideration to duct cover use.
12" Duct Cover
6" Duct Cover
Hood
6" duct
cover
12" duct
cover
ZV48
ZX48DC6 ZX48DC12
ZV36, ZV30 ZX36DC6 ZX36DC12
Dimensions (in inches)
6H or 12H x 19-11/16W x 11-7/8D
6H or 12H x 15-3/4W x 11-7/8D
605Dia142
30" Min.
36" Max.
Ceiling
Height
to Floor
1. Measure the exact ceiling height.
2. Review the chart at right to determine the range of hood
installation heights that can be accomplished with a 6"
or 12" duct cover accessory.
• Increase or decrease hood installation height to
accommodate the fixed 6" or 12" duct cover heights.
• Duct covers may be stacked, in various combinations,
to reach ceiling heights.
60
32" Min.
38" Max.
Ceiling
Height
to Floor
Note: When determining the installation height, consideration
must be given to the use of the warming shelf.
Using duct cover accessories
One or more duct cover accessories may be required for your
hood installation height. Use this chart to determine the size
and number of duct cover accessories required depending on
the use of the supplied warming shelf.
Installation height requirements
Restaurant-style hoods
These vent hoods must be installed 30" minimum to 36"
maximum above the standard 36"-high cooking surface.
When installed with the warming shelf, allow 32" minimum to
38" maximum clearance. The exact hood installation height is
determined by the ceiling height.
Duct Cover(s)
10" Hood
Height
Restaurant-style hoods
without warming shelf
installed
Restaurant-style hoods
with warming shelf
installed
Possible Possible
Duct
Duct
Actual
hood
hood
cover
cover
ceiling
installation
installation
height
height*
6"
12" height*
6"
12"
7' 11"
31"
1
1
37"
1
8' 0"
32"
1
1
32"
1
1
8' 0"
38"
1
8' 1"
33"
1
1
33"
1
1
8' 2"
34"
1
1
34"
1
1
8' 3"
35"
1
1
35"
1
1
8' 4"
30"
2
8' 4"
36"
1
1
36"
1
1
8' 5"
31"
2
37"
1
1
8' 6"
32"
2
32"
2
8' 6"
38"
1
1
8' 7"
33"
2
33"
2
8' 8"
34"
2
34"
2
8' 9"
35"
2
35"
2
8' 10"
30"
1
2
8' 10"
36"
2
36"
2
8' 11"
31"
1
2
37"
2
9' 0"
32"
1
2
32"
1
2
9' 0"
38"
2
9' 1"
33"
1
2
33"
1
2
9' 2"
34"
1
2
34"
1
2
9' 3"
35"
1
2
35"
1
2
9' 4"
30"
3
9' 4"
36"
1
2
36"
1
2
9' 5"
31"
3
37"
1
2
9' 6"
32"
3
32"
3
9' 6"
38"
1
2
9' 7"
33"
3
33"
3
9' 8"
34"
3
34"
3
9' 9"
35"
3
35"
3
9' 10"
30"
1
3
9' 10"
36"
3
36"
3
9' 11"
31"
1
3
37"
3
10' 0"
32"
1
3
32"
1
3
10' 0"
38"
3
*Based on 36" countertop height.
Note: Additional duct covers may be used to reach higher ceilings.
monogram.com
Installation height requirements
Using duct cover accessories
Tapered- and straight-sided hoods
These vent hoods must be installed 30" minimum to 36"
maximum above the standard 36"-high cooking surface.
The exact hood installation height is determined by the
ceiling height.
One or more duct cover accessories may be required
for your hood installation height. Use this chart to
determine the size, number or combination of duct cover
accessories required.
• Duct covers may be stacked, in various combinations,
to reach ceiling heights.
Duct Covers
18" Hood
Height
Ceiling Height
to Floor
Installation Height
Professional hoods
• Increase or decrease hood installation height to
accommodate the fixed 6" or 12" duct cover heights.
Tapered- or
straight-sided Straight-sided
hoods with
hoods only standard
with full-width
duct cover
duct cover
Duct
Duct
Actual
Possible hood
cover
cover
ceiling
installation
height
height*
6"
12"
6"
12"
7' 11"
35"
1
1
8' 0"
30"
1
1
8' 0"
36"
1
1
8' 1"
31"
1
1
8' 2"
32"
1
1
8' 3"
33"
1
1
8' 4"
34"
1
1
8' 5"
35"
1
1
8' 6"
30"
1
1
1
1
8' 6"
36"
1
1
8' 7"
31"
1
1
1
1
8' 8"
32"
1
1
1
1
8' 9"
33"
1
1
1
1
8' 10"
34"
1
1
1
1
8' 11"
35"
1
1
1
1
9' 0"
30"
2
2
9' 0"
36"
1
1
1
1
9' 1"
31"
2
2
9' 2"
32"
2
2
9' 3"
33"
2
2
9' 4"
34"
2
2
9' 5"
35"
2
2
9' 6"
30"
1
2
1
2
9' 6"
36"
2
2
9' 7"
31"
1
2
1
2
9' 8"
32"
1
2
1
2
9' 9"
33"
1
2
1
2
9' 10"
34"
1
2
1
2
9' 11"
35"
1
2
1
2
10' 0"
30"
3
3
10' 0"
36"
1
2
1
2
10' 1"
31"
3
3
10' 2"
32"
3
3
10' 3"
33"
3
3
10' 4"
34"
3
3
*Based on 36" countertop height.
Note: Additional duct covers may be used to reach higher ceilings.
Custom hood inser ts
2. Review the chart at right to determine the range of hood
installation heights that can be accomplished with a 6" or
12" duct cover accessory.
te l e s c o p i c
d o w n d r a f t v e nt s
1. Measure the exact ceiling height.
chimney hoods
Advance planning for professional hoods
The serial plate is located behind the removable filters.
61
Advance planning for professional island hoods
Installation height requirements
Using duct cover accessories
These vent hoods must be installed 30" minimum to 36"
maximum above the standard 36"-high cooking surface.
The exact hood installation height is determined by the
ceiling height.
A duct cover accessory may be required for your hood
installation height. Use this chart to accurately determine
the need for a duct cover accessory.
20" for ZV42I
24" for ZV54I
30" Min. and 36" Max.
Ceiling
Height
36"
to
Countertop
Accessory support frames with duct covers
ZX42DC10—Optional accessory for ZV42I, for use with ceiling
heights of 8'6" to 10'4". Kit includes telescoping support frames
and duct covers.
ZX54DC10—Optional accessory for ZV54I, for use with ceiling
heights of 8'6" to 10'4". Kit includes telescoping support frames
and duct covers.
Accessory ZX42DC10
Supplied
Duct Cover
Possible
Actual
hood
ceiling
installation Duct cover
height
height*
accessory
7' 11"
30"
8' 0"
31"
8' 1"
32"
8' 2"
33"
8' 3"
34"
8' 4"
35"
8' 5"
36"
8' 6"
30" to 31"
8' 7"
30" to 32"
8' 8"
30" to 33"
8' 9"
30" to 34"
8' 10"
30" to 35"
8' 11"
30" to 36"
9' 0"
30" to 36"
9' 1"
30" to 36"
9' 2"
30" to 36"
9' 3"
30" to 36"
9' 4"
30" to 36"
9' 5"
30" to 36"
9' 6"
30" to 36"
9' 7"
30" to 36"
9' 8"
30" to 36"
9' 9"
30" to 36"
9' 10"
30" to 36"
9' 11"
30" to 36"
10' 0"
30" to 36"
10' 1"
30" to 36"
10' 2"
30" to 36"
10' 3"
31" to 36"
10' 4"
32" to 36"
*Based on 36" countertop height.
ZV54
installation heights
Possible
hood
installation
height*
30"
31"
32"
33"
34"
35"
36"
30"
30" to 31"
30" to 32"
30" to 33"
30" to 34"
30" to 35"
30" to 36"
30" to 31"
30" to 32"
30" to 33"
30" to 34"
30" to 35"
30" to 36"
30" to 36"
30" to 36"
30" to 36"
30" to 36"
31" to 36"
32" to 36"
33" to 36"
34" to 36"
35" to 36"
36"
Duct cover
accessory
The serial plate is located behind the removable filters.
62
Supplied
2. Review the chart at right to determine the range of hood
installation heights that can be accomplished with or
without an accessory kit.
ZV42
installation heights
Accessory ZX54DC10
1. Measure the exact ceiling height.
Pairing hoods with cooking equipment
Monogram® hoods are designed to perfectly coordinate with Monogram ranges and cooktops. To learn which cooking products can
be combined with the hood you have selected, refer to the charts below.
Wall-mounted
ZV755SPSS
ZV750SPSS
ZV800SJSS
ZV830SMSS
ZV925SLSS
Downdraft
ZVB36STSS
ZVB30STSS
All non-pro
cooktops
All non-pro
cooktops
All 30" non-pro All non-pro
cooktops
cooktops
All 30" and 36"
cooktops and All non-pro
ranges
cooktops
All 30" and 36"
cooktops and All non-pro
ranges
cooktops
All non-pro
cooktops
Chimney
Chimney
(slide-out)
Chimney
Chimney
Chimney
Chimney
Chimney
Chimney
Telescopic
downdraft
36"
36"
30"
36"
36"
36"
42"
36"
36"/30"
460 CFM
420 CFM
490 CFM
690 CFM
1040 CFM
490 CFM
390 CFM
7.0
220/2.0
9.0
190/2.0
8.0
230/2.0
6.0
330/1.3
10.0
450/2.5
8.0
230/2.0
10.5
170/2.5
8'–10' options
8'–12' options
8'–10' 5" options No
8'–10' 4" options No
8'–10' 1" options No
8' to 10' duct
cover included;
or undercabinet
option
7'11" to 10' duct
cover included;
10' to 12' duct
cover optional
8' to 9' 5" duct
cover included;
9' 6" to 10' 5" duct
cover optional
8', 9' or 10' duct
cover included;
10' to 14' duct
cover optional
8' to 8' 7" duct
cover included;
9' to 10' 1" duct
cover optional
8'1" duct cover
­included, 8'2"
or 10' duct
cover optional
8' to 9' duct
cover included;
9' 1" to 10' 1" duct Indoor remote
cover optional blower option
6" round
8" round
8" round
8" round
6" round
8" round
8" round
3-1/4" x 10" rect.
100'
100'
100'
100'
100'
100'
100'
100'
ZV900SLSS
ZV950SDSS
Island
ZV855SPSS
ZV850SPSS
ZV1050SFSS
Installation
combinations
Style
Width
High speed
­blower rating
490 CFM
350 CFM
10.0, 6.0
Sones
210/2.0,
working speed 170/1.1
Recirculating
option
8'–10' 8" options
Vented duct
cover options
8' to 9' 2" duct
cover included;
9" to 10' 3" duct
cover optional
Duct size
6" round
Equivalent
duct length
100'
Professional wall-mounted
ZV48TSFSS
ZV48SSFSS
ZV36TSFSS
ZV36SSFSS
ZV30TSFSS
ZV30SSFSS
ZV48RSFSS
ZV36RSFSS
ZV30RSFSS
All Monogram
cooktops and
ranges
All Monogram
cooktops and
ranges
Tapered
490 CFM
350 CFM
10.0, 6.0
210/2.0,
170/1.1
Professional island
Wall or island hood inserts
ZV30HSRSS
ZV42ISHSS
ZV54ISHSS
ZVC36LSS
Zvc30LSS
ZVC48LSS
ZVC42LSS
All Monogram
cooktops and
ranges
All Monogram
30" cooktops
and ranges
All 30" and 36"
cooktops
All Monogram
cooktops and
ranges
All 30" and 36"
cooktops and
ranges
All Monogram
cooktops and
ranges
Straight
Restaurant
Wall-mounted/
undercabinet
Tapered
Tapered
Insert
Insert
48"/36"/30"
48"/36"/30"
48"/36"/30"
30"
42"
54"
36"/30"
48"/42"
1090/620/620
CFM
13.0, 9.0
430/2.5
240/1.1
1090/620/620
CFM
13.0, 9.0
430/2.5
240/1.1
1090/620/620
CFM
13.0, 9.0
430/2.5
240/1.1
530 CFM
1090 CFM
1090 CFM
640 CFM
1140 CFM
9.0
240/2.0
13.0
430/2.5
13.0
430/2.5
14.0
250/3.5
16.5
490/4.0
No
No
No
Yes
No
No
No
No
Optional 6" and
12" duct covers;
stackable
Optional 6" and
12" duct covers,
standard or
full-width;
stackable
Optional 6" and
12" duct covers,
standard or
full-width;
stackable
7'11" to 8'5" duct
3-1/2 risers with cover included,
8'6" to 10'4" duct
and without
­louvers included cover optional
7'11" to 8'5" duct
cover included,
8'6" to 10'4" duct
cover optional
N/A
N/A
10" round
10" round
10" round
8" round
10" round
10" round
8" round
8" round
150'
100'
150'
150'
100'
100'
Installation
combinations
Style
Width
Blower rating
Sones
working speed
Recirculating
option
Vented duct
cover options
Duct size
Equivalent
duct length
42
150'
150'
Note: Cooktop or range not to exceed vent hood width
chimney hoods
monogram.com
The Home Ventilating Institute (HVI) is a third-party certification
organization focused on providing a fair and credible method
of comparing ventilation performance of similar products.
Many agencies such as Energy Star® and ASHRAE utilize
HVI certification for performance assurance. All Monogram
ventilation products are certified by HVI.
professional hoods
Some key performance criteria measured by HVI are sound
level measured in sones, high speed and working speed
measured in cubic feet per minute (cfm).
A sone is an internationally recognized measurement of sound
output. Sones translate decibel ratings into numbers that
correspond to the way people sense loudness. The lower the
sone number the quieter the sound.
Working speed is defined as the speed that produces
100 cfm, or the lowest speed above 100 cfm that a hood
can produce, when working on the same duct system as the
maximum speed.
te l e s c o p i c
d o w n d r a f t v e nt s
Custom hood inser ts
(HVI916, March 1, 2009) (http://hvi.org/faqs.html)
43
Was this manual useful for you? yes no