Miele | 51608065USA | Installation Plan | Miele 51608065USA Installation Plan

Installation Plan
Washer-extractor
PW 6080 EL (Electrically Heated)
en - US
50.16
M.-Nr. 10 181 930 / 02
U.S.A.
Miele, Inc.
National Headquarters
9 Independence Way
Princeton, NJ 08540
Phone: 800-991-9380
Fax:
609-419-4241
www.mieleusa.com
Technical Service & Support
Nationwide
Phone: 800-991-9380
Fax:
800-220-1348
proservice@mieleusa.com
It is essential to read the operating and installation instructions before installing,
commissioning or using the machine.
This avoids the risk of accidents or damage.
All rights reserved.
M.-Nr. 10 181 930
2
27 9/16"
19 1/2"
40 3/16"
28 5/8"
UG 13 1/4"
15 3/16"
UO 12"
UG 13 1/4"
27 3/16"
52 3/16"
14 9/16"
2"
17 5/16"
UO 12" 12 13/16"
27 1/4"
40 3/16"
2"
28 3/8"
43 5/16"
27 9/16"
2"
27 1/4"
28 5/8"
2"
27 9/16"
27 1/4"
14 9/16"
15 3/16"
40 3/16"
27 3/16"
28 3/8"
43 5/16"
PW 6080 EL - measurements in inches
3
Version with drain pump (LP)
3 15/16"
19 3/8"
3 15/16"
< 35 7/16"
< 39 3/8"
51 3/16"
UG 13 1/4"
UO 12"
51 3/16"
UO 12"
UG 13 1/4"
< 39 3/8"
3 15/16"
23 5/16"
19 3/8"
< 35 7/16"
< 39 3/8"
51 3/16"
< 39 3/8"
51 3/16"
3 15/16"
5 3/8"
PW 6080 EL - measurements in inches
4
Version with drain valve (AV)
3 15/16"
23 5/16"
19 3/8"
51 3/16"
3 3/8"
1 9/16"
UO 12"
UG 13 1/4"
UO 12"
UG 13 1/4"
5 3/8"
3 3/8"
51 3/16"
3 15/16"
31 11/16"
3 15/16"
23 5/16"
19 3/8"
51 3/16"
3 3/8"
5 3/8"
3 3/8"
< 39 3/8"
51 3/16"
3 15/16"
1 9/16"
31 11/16
PW 6080 EL - measurements in inches
5
2"
2 9/16"
1/2"
PW 6080 EL - measurements in inches
22 1/16"
17 3/8"
12 1/4"
24 9/16"
2 13/16"
21 5/8"
17 5/16"
27 1/4"
10 13/16"
2 13/16"
3 15/16"
27"
43 5/16"
24 11/16"
27" / UO 26 7/8"
43 5/16"
27 1/4" / UO 26 3/4"
1 1/2"
3/8"
6
13/16"
12 5/8"
UG 13 1/4"
UO 12"
13/16"
39 3/8"
40 3/16"
13/16"
40 3/16"
40 3/16"
17 5/16"
13/16"
11 13/16"
3"
3"
21 5/8"
39 3/8"
27 3/16"
43 5/16"
27 1/4"
10 13/16"
21 5/8"
2 13/16"
2 13/16"
3 15/16"
10 13/16"
3 15/16"
22 1/16"
27 9/16"
43 5/16"
27 9/16"
1 9/16"
3/8"
PW 6080 EL - measurements in inches
2"
2"
1 9/16"
3/8"
7
PW 6080 EL - measurements in millimeters
8
<
<
<
<
<
<
Version with drain pump (LP)
PW 6080 EL - measurements in millimeters
9
Version with drain valve (AV)
PW 6080 EL - measurements in millimeters
10
PW 6080 EL - measurements in millimeters
11
PW 6080 EL - measurements in millimeters
12
Technical datasheet
PW 6080
Electric (EL)
Washer-extractor:
Heating:
Legend:
Abbreviations in bold type:
Connection required
en - US
Abbreviations in circle with dashes:
Connection optional or required depending on model version
Optional extras:
UM
BS
Miele base
Concrete base
UO 6008 (UO = open base)
Height
Width
Depth
12''
26 15/16''
27 1/16''
305 mm
684 mm
687 mm
UG 6008 (UG = closed base)
Height
Width
Depth
12''
27 1/4''
27 1/16''
305 mm
692 mm
688 mm
US 6008 (US = base with drawer)
Height
Width
Depth
12 5/8''
27 1/4''
27''
320 mm
692 mm
685 mm
11 13/16''
2 3/4''
≥27 9/16''
≥27 9/16''
300 mm
70 mm
≥700 mm
≥700 mm
Quality and density of concrete must comply with load.
Concrete base must be firmly secured to floor!
Recommended height
Minimum height
Recommended width
Recommended depth
Dispensing pump External dispensing pumps (2 or 4 head pump):
Voltage (external power supply required)
Fusing
Supplied with supply cable and plug
120V
15A
NEMA 5-15
Machine connections:
Electrical
connection
(convertible)
1. Standard voltage (2 AC 220-240V 60Hz)
Voltage
Frequency
Rated load
Fuse rating
Length of supply lead
Supplied with plug
V
Hz
kW
A
78 3/4''
NEMA L6-30P
2 AC 220-240V
60
4.4 - 5.2
2 × 30
2000 mm
NEMA L6-30P
2. Standard voltage (2 AC 208V 60Hz)
Voltage
Frequency
Rated load
Fuse rating
Length of supply lead
Supplied with plug
V
Hz
kW
A
78 3/4''
NEMA L6-30P
2 AC 208V
60
4.0
2 × 30
2000 mm
NEMA L6-30P
Technical datasheet: PW 6080 LP/AV
Date: 2016-Dec-12
Page: 13
Electrical connection must comply with national regulations.
Connection using multi-pole wall lockable socket in compliance with IEC/EN 60309 and IEC/EN 60947 is recommended
in order to simplify electrical tests. If machines are hard-wired,
a multi-pole mains switch must be provided on site. Switches
with a contact gap of more than 3 mm can be used. These
include switches, fuses and contactors (IEC/EN 60947). A
wall socket or mains isolator must be easily accessible after
installation.
Reinstallation of the supply point, changes to the equipment
or checks on the protective conductor, including determination
of correct fuse rating, should only be performed by a properly
trained electrician.
If necessary, equipotential bonding with good galvanic contact
must be provided in accordance with all appropriate national
and local regulations.
Cold water
(Soft water)
Min. flow pressure
Max. pressure
Max. throughput
On-site connection thread
Length of connection hose
(supplied: 1 connection hose)
Hourly water demand (average for 60°C program) for standard connection (with hot and cold water)
If hot water supply is not available, connect hot water
inlet to cold water inlet.
Hot water
(Soft water)
Max. temperature
Min. flow pressure
Max. pressure
Max. throughput
On-site connection thread
Length of connection hose
(supplied: 1 connection hose)
Hourly water demand (average for 60°C − program)
When reprogrammed by Miele Service, the Machine can
also be connected to a hot water supply line with a
temperature of 70 °C (158 °F) to max. 85 °C (185 °F) . This
requires a separate inlet hose. This additional inlet hose is
available from Miele.
Technical datasheet: PW 6080 LP/AV
Date: 2016-Dec-12
14.5 psi
145 psi
2.9 gal/min
3/4" garden
hose thread,
male
61''
100 kPa
1000 kPa
11 l/min
3/4" garden hose
thread, male
approx. 18.5
gal/hr
approx. 70 l/hr
158°F
14.5 psi
145 psi
2.9 gal/min
3/4" garden
hose thread,
male
61''
70 °C
100 kPa
1000 kPa
11 l/min
3/4" garden hose
thread, male
approx. 18.5
gal/hr
approx. 70 l/hr
1550 mm
1550 mm
Page: 14
Drain pump
Max. temperature
Drain hose (int. diameter)
On-site hose connector for drain hose
(int. diameter x length)
Max. transient throughput
Drain pump head height (from floor level)
203 °F
7/8''
7/8'' x 1 3/16''
95 °C
22 [DN 22] mm
22 x 30 mm
6.9 gal/min
39 3/8”
26 l/min
1000 mm
203 °F
2 15/16''
2 15/16''
16.4 gal/min
95 °C
75 [DN 70] mm
75 [DN 70] mm
62 l/min
Vented drainage required. If ventilation is insufficient, fit Miele
kit, Mat. no. 05238090.
Drain manifolds serving several machines must be of sufficient cross-section.
Dump valve
Max. temperature
Machine-side drain connection (ext. diameter)
On-site drain (int. diameter)
Max. transient throughput
Vented drainage required. If ventilation is insufficient, fit Miele
kit, Mat. no. 05238090.
Drain manifolds serving several machines must be of sufficient cross-section.
Fittings for base Miele base UG/UO 6008
/ floor installa- 4 × metal angled brackets
tion
(to secure machine to base)
4 × screws DIN 571 (Ø × length)
5/16'' x 2 9/16'' 8 x 65 mm
4 × rawl plugs (Ø × length)
1/2'' x 2 3/8“ 12 x 60 mm
Base must be bolted to the floor. Machine must be fixed to the
base.
Fixing materials for a floating screed floor are to be provided
on site.
Miele US 6008 base
4 × metal angled brackets
(to secure machine to base)
4 × screws DIN 571 (Ø × length)
1/4'' x 2“
4 × rawl plugs (Ø × length)
5/16'' x 1 9/16''
Base must be bolted to the floor. Machine must be fixed to the
base.
Fixing materials for a floating screed floor are to be provided
on site.
Installation on floor or concrete base
2 × clamps
2 × screws DIN 571 (Ø × length)
2 × rawl plugs (Ø × length)
Machine must be bolted to the base or floor. Fittings are
supplied with machine.
Fixing materials for a floating screed floor are to be provided
on site.
Machine data
1/4'' x 2''
5/16'' x 1 9/16''
6 mm x 50 mm
8 mm x 40 mm
6 mm x 50 mm
8 mm x 40 mm
Unit width
Unit depth
Unit height
Casing width
Casing depth
27 9/16''
28 5/8''
40 3/16''
27 1/4''
27 3/16''
700 mm
727 mm
1020 mm
692 mm
690 mm
Minimum width of delivery access to installation site
Recommended rear wall gap (measured to front of machine)
Minimum rear wall gap (to front of machine)
Recommended rear wall gap ensures sufficient space for
maintenance and servicing.
28 3/8''
43 5/16''
35 7/16''
720 mm
1100 mm
900 mm
Net weight
Dynamic floor load, max.
Static floor load, max.
Dynamic load, max.
Drum frequency, max.
Average heat dissipation
(dependent on ambient room temperature and
program selected)
309 lbs
2600 N
1850 N
750 N
22 Hz
2830 BTU/hr
140 kg
2600 N
1850 N
750 N
22 Hz
0.83 kWh
Sound pressure (re 20 mPA),
workplace-related (at distance of 1 m and height of 1.6 m)
<70 dB (A)
<70 dB (A)
Installation should only be carried out by authorized installers in accordance with valid regulations! Observe installation
instructions when installing machine! All rights reserved!
Technical datasheet: PW 6080 LP/AV
Date: 2016-Dec-12
Page: 15
Download PDF