Whirlpool | WED4616FW | Dimensions Guide | Whirlpool WED4616FW Dimensions Guide

Whirlpool WED4616FW Dimensions Guide
Gas Dryer
PRODUCT MODEL NUMBERS
WGD4800B, WGD4810B, WGD4850B, WGD4890B,
WGD5500B, WGD5800B, WGD5810B, WGD4870B,
WGD5000D, WGD4810E, WGD4815E, WGD4915E,
WGD4975E, WGD4616F, WGD4916F
27" Wide Models
Dryer Dimensions
29" Wide Models
Dryer Dimensions
29"
(737 mm)
27"
(686 mm)
29"
(737 mm)
433/8"
(1102 mm)
433/8"
(1102 mm)
43"
(1092 mm)
1/2"
(13 mm)
11/2"
(38 mm)
11/2"
(38 mm)
NOTE: Leveling legs should be 1/2" (13 mm) (to match height of
3.6 cu. ft. capacity washer) or 1½" (38 mm) (to match height of
3.8 cu. ft. capacity washer).
22 / "
(578 mm)
3 4
27 / "
(705 mm)
3 4
133/4"
(349 mm)
223/4"
(578 mm)
291/2"
(749 mm)
133/4"
(349 mm)
291/2"
(749 mm)
273/4"
(705 mm)
A
B
A. Wide opening side-swing door
B. Wide opening hamper door
A
B
A. Wide opening side-swing door
B. Wide opening hamper door
Installation Spacing
14" max.*
(356 mm)
Installation Spacing
14" max.*
(356 mm)
18"*
(457 mm)
3"*
(76 mm)
48 in.2*
2
(310 cm )
18"*
(457 mm)
2
24 in.2 * 2
(155 cm )
29"
(737 mm)
A
1"* 27¾"
1"
(25 mm) (25 mm) (705 mm)
B
A. Recessed area
B. Side view – closet or confined area
C. Closet door with vents
*Required spacing
48 in.*
2
(310 cm )
24 in.* 2
(155 cm )
1"
(25 mm)
1"
(25 mm)
3"*
(76 mm)
2
3"*
(76 mm)
C
3"*
(76 mm)
27"
1"
1"*
29½" 5½"*
(686 mm) (25 mm) (25 mm)(749 mm) (140 mm)
B
C
A
A. Recessed area
B. Side view – closet or confined area
C. Closet door with vents
*Required spacing
W10562360A
05/2016
Installation clearances:
The location must be large enough to allow the dryer door to
open fully.
Most installations require a minimum 5½" (140 mm) clearance
behind the dryer for the exhaust vent with elbow. See “Venting
Requirements.”
Installation spacing for recessed area or closet
The dimensions shown are for the minimum spacing allowed.
■■ Additional spacing should be considered for ease of installation
and servicing.
■■ Additional clearances might be required for wall, door, and floor
moldings.
■■ Additional spacing of 1" (25 mm) on all sides of the dryer is
recommended to reduce noise transfer.
■■ For closet installation, with a door, minimum ventilation
openings in the top and bottom of the door are required.
Louvered doors with equivalent ventilation openings are
acceptable.
■■ Companion appliance spacing should also be considered.
INSTALLATION REQUIREMENTS
GAS SUPPLY REQUIREMENTS
Gas supply: This dryer is equipped for use with Natural gas. Dryer can be converted to L.P. gas. When rigid pipe is used it should be 1/2" IPS. When
acceptable to the gas supplier and local codes, 3/8" approved tubing may be used for lengths under 20 ft (6.1 m). For lengths over 20 ft (6.1 m), larger
tubing should be used. Pipe-joint compounds resistant to the action of L.P. gas must be used. An individual manual shutoff valve must be installed
within 6 ft (1.8 m) of the dryer in accordance with the National Fuel Gas Code ANSI Z223.1.
ELECTRICAL REQUIREMENTS
A 120-volt, 60 Hz, AC-only, 15 or 20 amp fused electrical supply is required. A time-delay fuse or circuit breaker and a separate circuit
are recommended.
VENTING REQUIREMENTS
Exhaust venting: Exhaust your dryer to the outside. 4" (102 mm)
diameter vent is required. Rigid or flexible metal exhaust vent
must be used. Do not use plastic or metal foil vet. Exhaust hood
must be at least 12" (305 mm) from the ground or any object that
may be in the path of the exhaust.
Determine vent length and elbows needed for best
drying performance:
■■ Use following Vent System Chart to determine type of vent
material and hood combinations acceptable to use.
NOTE: Do not use vent runs longer than those specified
in Vent System Chart. Exhaust systems longer than those
specified will:
Exhaust hoods:
Recommended Styles:
■■ Shorten life of dryer.
■■ Reduce performance, resulting in longer drying times
and increased energy usage.
Louvered Hood
Box Hood
The “Vent System Chart” provides venting requirements that will
help achieve best drying performance.
Acceptable Style:
Vent System Chart
Number of
90° turns or
elbows
Type
of vent
Box/louvered
hoods
Angled
hoods
0
Rigid metal
64 ft. (20 m)
58 ft. (17.7 m)
Angled Hood
1
Rigid metal
54 ft. (16.5 m)
48 ft. (14.6 m)
Determine vent path:
2
Rigid metal
44 ft. (13.4 m)
38 ft. (11.6 m)
3
Rigid metal
35 ft. (10.7 m)
29 ft. (8.8 m)
4
Rigid metal
27 ft. (8.2 m)
21 ft. (6.4 m)
■■ Select route that will provide straightest and most direct
path outdoors.
■■ Plan installation to use fewest number of elbows and turns.
■■ When using elbows or making turns, allow as much room
as possible.
■■ Bend vent gradually to avoid kinking.
■■ Use as few 90° turns as possible.
NOTE: Side and bottom exhaust installations for 27" wide
models have a 90º turn inside the dryer. To determine
maximum exhaust length, add one 90º turn to the chart.
Vent System Chart
(29" Wide Long Vent Models Only)
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Number of
90° turns
or elbows
Type
of vent
Box/louvered, or
Angled hoods
0
Rigid metal
120 ft. (36.6 m)
1
Rigid metal
110 ft. (33.5 m)
2
Rigid metal
100 ft. (30.5 m)
3
Rigid metal
90 ft. (27.4 m)
4
Rigid metal
80 ft. (24.4 m)
5
Rigid metal
70 ft. (21.3 m)
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.