Frigidaire | FGHG2368TF | Wiring diagram | Frigidaire FFHN2750TS Wiring Diagram

Frigidaire FFHN2750TS Wiring Diagram
PERFORMANCE DATA NO LOAD & NO DOOR OPENINGS AT 37°/0°
CONTROL SETTING
Type A with Run /
Start Capacitor
65°F (18°C) Ambient
Operating Time
90°F (32°C) Ambient
SERVICE DATA SHEET
A06686901
FREEZER ICE MAKER - AUTOMATIC DEFROST
90 to 100%
100%
-5° to 2°F
(-20° to -17°C)
-1° to 3°F
(-18° to -16°C)
34° to 39°F
(1° to 4°C)
34° to 39°F
(1° to 4°C)
Low Side Pressure
-2 to 6 psig
(-14 to 41 kPa)
-2 to 6 psig
(-14 to 41 kPa)
High Side Pressure
(last 1/3 cycle)
85 to 105 psig
(586 to 724 kPa)
120 to 135 psig
(827 to 931 kPa)
FZ
FF
Wattage (last 1/3 cycle)
30 to 50
50 to 70
--
OP
Amps (running)
.4 to .8
.7 to .9
Open FF
Cavity Thermistor
OP
--
Open FZ
Cavity Thermistor
--
SH
Shorted FZ
Sabbath
Cavity
Thermistor
→ Remove
inverter box from the
SH
--
Freezer Temperature
Refrigerator Temperature
Base Voltage
IMPORTANT: PLEASE RETURN THIS SHEET TO ITS ORIGINAL LOCATION.
ERROR CODES
Display
DEFROST SPECIFICATIONS
Cabinet Size:
Check
at the Cutout
connector from the power
cord
Thermal
Heater
harness into the inverter board, located in
the machine compartment.
yes
(PUR and WHT wires)
Cut-in
Cut-out
Watts
Is Inverter Board receiving 115 VAC
110°F
135°F
500
from
power supply?
(43.3°C)
(57.2°C)
27’ & 28’ SD, 22’ CD
→
CheckDefrost
at Inverter Board on
Compressor
Heater
(BLK
and RED wires)
Termination
26.5
no
Watts
SY
RPM
CE
Amps
supply.
0.03 Running
• CheckShaft
and repair power
Opposite
cord harness wiring and
→ Check at Main Control Board
FREEZER ICEconnections.
MAKER SPECIFICATIONS
(BLK/WHT and RED/BLK wires)
•1100
Check
CWvoltage
3.1
Electrical
115 vac (127 vac max)
Thermostat
Opens at 48°F ( 9°C), Closes at 15° F ( -9°C)
Heater Voltage
115 vac
Mode
SY
EF
no
Display
Activate
Deactivate
ICE MAKER
MOTOR
RED
RED
NC
C
LT. BLUE
NO
P-4
THERMOSTAT
BLU
BLK
C
MOLD HEATER
165 WATTS
NO
GRN / YEL
P-1
C
MOLD
MOUNTING
PLATE
ICE MAKER
NC
WATER FILL
SWITCH
NC
SHUTOFF
SWITCH
YELLOW
P-2
Passing result
Blank UI display, no LEDs illuminated.
--
Second Screen
--
All LED lights on UI illuminated.
Third Screen
--
Blank UI display, no LEDs illuminated.
F
FF ^ and FF v
Same to
deactivate
46
Humidity Sensor
Activates
automatically
Demo /
Showroom
77
77
FZ ^ and FF v
Unplug to
deactivate
“OP” if open, “SH” if short. AC Heater System: Displays
%RH. DC Heater System: “HI” - heater should be on. “Lo”
- heater should be off. %RH is displayed when humidity is
between “Lo” and “HI” values; heater could be on or off.
Sb
Sb
FZ v and FF ^
Same to deactivate
2
Freezer
Defrost Heater
Press power on-off
Freezer defrost heater on when “on”; off when “off”. Evaporator thermistor temperature is flashed. Watch for temp
increase with the heater on. It may take a few minutes for
the evaporator to heat up.
12
Condenser Fan
Press power on-off
Fan running when “on”; stopped when “off”
43
Mullion Anticon- Press power on-off
densation Heater
Flip Mullion Heater on when “on”; off when “off”
38
VCC Compressor
Press power on-off
Compressor on when “on”; off when “off”
13
FF Lights
Press power on-off
FF lights on when “on”; off when “off”
15
Freezer
Evaporator Fan
Press power on-off
Press to toggle between “off”, “Lo” and “HI”. A current sensor reading is flashed (units are not mA). OFF reading should
be around 2. “Lo” speed reading should settle down to
around 9. “HI” speed reading should settle down above 40.
20
FZ Lights
Press power on-off
FZ lights on when “on”; off when “off”
22
Damper
Press power on-off
Perform test 15 and set fan to “HI”. Then, check for air flow
when open “OP,” and no air leaks when closed “CL”.
23
FF Door
Open/close FF door “CL” on UI when door closed; “OP” when open
24
FZ Door
Open/close FZ door “CL” on UI when door closed; “OP” when open
29
FF Thermistor
Activates
automatically
UI shows temperature sensed by FF thermistor; pass if
within 10°F of temperature measured with gauge at FF
thermistor location.
“OP” if open; “SH” if short
30
FZ Thermistor
Activates
automatically
UI shows temperature sensed by FZ thermistor; pass if
within 10°F of temperature measured with gauge at FZ
thermistor location.
“OP” if open; “SH” if short
33
Ambient Thermistor @ Main
Board
Activates
automatically
UI shows temperature sensed at main board; pass if within
+20°F/-10°F of temperature measured with gauge at main
board location.
“OP” if open; “SH” if short
34
Ambient Thermistor @ UI
Activates
automatically
UI shows temperature sensed at UI; pass if within +20°F/10°F of temperature measured with gauge at UI location.
“OP” if open; “SH” if short
39
Freezer
Evaporator
Thermistor
Activates
automatically
UI shows temperature sensed by freezer evaporator thermistor; pass if within 10°F of temperature measured with gauge
at evaporator thermistor location. “OP” if open; “SH” if short
0-
Firmware
Parameters
Press power on-off
Displays digit sequence; record
1-
Main Board
Firmware
Press power on-off
Displays digit sequence; record
3-
UI Firmware
Press power on-off
Displays digit sequence; record
→
Check connections from Inverter
Board to Compressor
Blank UI
display, FZ ^ and FZ v
Press and hold FF
yes
Are connections from Inverter^ to deactivate
no LEDs
Board to Compressor intact?
illuminated
FZ
Temp
FF
Temp
Default Settings
and C/F Buttons
Automatically
after 10 seconds
no
Replace Main Control Board.
VCC Resistance Check
Replace Inverter Board
Check resistance between terminals 1 and
2, 2 and 3, 3 and 1.
If all resistances are equal,
compressor is operative.
All electrical parts and wiring must be shielded from torch flame. DO NOT allow torch to touch
insulation; it will char at 200°F and flash ignite (burn) at 500°F. Excessive heat will distort the
plastic liner.
FREEZER ICE MAKER INFORMATION
Test Cycling: Remove cover by inserting screwdriver in notch
at bottom and prying cover from housing. Use screwdriver to
rotate motor gear counterclockwise until holding switch circuit
is completed. All components of ice maker should function to
complete the cycle.
Water Fill
Adjustment
Motor
Gear
TU
R
N
NO
RED
HOLD
SWITCH
--
d
(Where Applicable)
WATER VALVE
ICE MAKER
BLK
THERMAL
CUT-OUT
LT. BLUE
P-3
ICE MAKER
BRN
BLK
To activate test:
First Screen
Manual Defrost
CAUTION
NEUTRAL
Test
--
(Press for up to 10 sec. simultaneously)
VCC COMPRESSOR MOTOR RESISTANCE CHECK
yes
• Tests marked with “*” may not be applicable to this unit and will not be displayed in System DiagnosticMode.
• Tests displayed in diagnostic mode but not described below are for internal purposes only; advance through.
• View UI display for “on,” “off,” “CL,” “OP,” “SH,” “LO,” “HI” or numerical results of tests.
• Listen for operating sounds; feel for heat or air flow as appropriate to determine results of tests.
FF
UI to Main Board
Notes:
communication
• Always
Replace Compressor
and check for pin back-outs, pinched or damaged wires before
Identify and repair damaged
Inverter
Board.
error; after
a period
replacing components.
wires or poor connections
of operation
• Determine whether failure isbetween
causedInverter
by the component,
Board and main control
board
or
wiring.
Contact
TID
before
replacing
main control board.
Compressor.
Freezer Evaporator
• Refer to Service Manual for additional information.
yes
Fan Failure
Is Main Control Board sending
10-15 VAC and 1-5 VDC to
Inverter Board?
POWER
Press FF ^ for up to 10 sec. Diagnostic Mode will automatically deactivate after 10
min. of inactivity.
Note: Silence alarm.
FZ
Is resistance across all winding
UI to Main Board
Current Air
pairs equal?
communication
Temps
failure; on startnoup
Identify and repair damaged wires or
poor connections between Main Control
Board and Inverter Board.
LINE
Deactivate:
--
compressor and check resistance
Shorted
FZ
System
across compressor winding pairs as
yes Thermistor
Diagnostic
shown.
no
CONDENSER FAN MOTOR
SPECIAL MODES
Interpretation
Is Inverter
Cut-outBoard receiving 10-15
VAC and 1-5 VDC from MainSY
CF
Control48°F
Board?
(8°C)
Ohms
Press FZ ^ and FZ v for up to 10 sec. simultaneously. Press FF ^ to advance
through tests.
BOTTOM FREEZER - R134a
115 vac (127 vac max)
→
SYSTEM DIAGNOSTIC MODE
Activate:
Water Fill Volume: The water fill adjustment screw will
change the fill time. One full turn is equal to 20cc (.68 oz.).
The correct fill is 102 to 130cc (3.4 to 4.3 oz.). When a water
valve is replaced, the fill volume must be checked.
Mounting
Plate
Screw
Mounting
Plate
Screws
IMPORTANT SAFETY NOTE
The information provided herein is designed to assist qualified repair personnel only. Untrained persons should
not attempt to make repairs due to the possibility of electrical shock. Disconnect power cord before servicing
this appliance.
Timing
Gear
IMPORTANT
If any green grounding wires are removed during servicing, they must be returned to their original position
and properly secured.
LED LIGHT WIRING
1
2
J9
3
4
LED
LED
RG-5
1
2
3
4
1
2
3
4
WHT/BLU
WHT/BLU
WHT/BRN
WHT/BRN
WHT/BLU
LED
3
J2 2
1
USER
INTERFACE
PIN 3
PIN 4
PIN 5
RG-3
RG-4
RG-2
RG-6
WHT/BRN
WHT/BRN
WHT/BLU
WHT/BLU
LED
LED
WHT/BRN
RG-1
RG-7
LH1
WHT/BRN
WHT/BRN
WHT/BLU
WHT/BLU
LED
LED
WHT
4
3
2
1
RED
FREEZER
EVAPORATOR
SENSOR
4
3
2
1
GRY/YEL
GRY/WHT
2
FREEZER
SENSOR
GRY/WHT
1
MB1
PIN 7
FRESH FOOD
SENSOR
REFRIGERATOR LEDS
PIN 8
4
3
2
1
WHT/BRN
WHT/BRN
WHT/BLU
WHT/BLU
EVAPORATOR
FAN (DC)
LED
FZ-1
2
PIN 2
1
PIN 1
3
PIN 3
FREEZER LEDS
TYPICAL LED CONNECTOR
BLK
1
RED/BLK
1
RED/YEL
PIN 5
BRN/YEL
BLK/YEL
WHT/YEL
BLK/YEL
PIN 3
WHT/YEL
PIN 2
YEL/PNK
FREEZER DOOR
SWITCH
(DOOR OPEN)
INLINE CONNECTOR ABBREVIATION KEY
ABBR.
EXPLANATION
AT1 9 PIN CONNECTION AT AIR TOWER
5 PIN CONNECTION AT THE LEFT
LH1
DOOR UPPER HINGE
9 PIN CONNECTION IN THE MAIN
MB1 BOARD HOUSING BEHIND THE TOE
GRILLE
4 PIN CONNECTION IN THE MAIN
MB2 BOARD HOUSING BEHIND THE TOE
GRILLE
9 PIN CONNECTION IN THE
MC1 MACHINE COMPARTMENT TO THE
LEFT OF THE COMPRESSOR
2 PIN CONNECTION AT THE RIGHT
RH1
DOOR UPPER HINGE
YEL/PNK
BLK/ORN
BLK
MB1
PIN 4
PIN 5
RL5
RL4
+5V DC
RL6
RL8
+5V DC
NEUTRAL
+12V DC
BLK
U2 (SSR1)
1
J1 2
3
J2 3
7
J3 2
4
J2 6
J3 6
LT. BLU
LT. BLU
BASE PLATE
GROUND
BLK
YEL/RED
YEL/BLK
LT.BLU/BLK
BLK/PNK
MC1
MC1
FLIP MULLION COVER
RIGHT HINGE
GROUND
PIN 2
GRN/YEL
LT. BLU
PIN 3
LT.BLU/BLK
PIN 8
2
PIN 2
3
PIN 1
1
RH1
PIN 6
MULLION HEATER
LT. BLU
RED
CONDENSER FAN
YEL FREEZER ICEMAKER
WATER VALVE
LT. BLU
MAIN INLET
WATER VALVE
+12V DC
YEL
GND
LINE
NEUTRAL
RL2
+12V DC
1
J2 5
2
BLK
PIN 1
YEL/BLU
BLK
PIN 3
LT. BLU
BRN
BLK/ORN
PIN 2
YEL/PNK
YEL/PNK
PIN 4
THERMAL
FREEZER
EVAPORATOR CUT-OUT
HEATER
MB2
OUT1A
OUT1B
OUT2A
ERF2500++ISO
REFRIGERATOR
CONTROL
OUT2B
FREEZER DOOR
SWITCH
(DOOR OPEN)
4
FREEZER
ICE MAKER
(SEE FZ ICE
MAKER DIAGRAM)
3
YEL/BLU
2
1
GRN/YEL
COIL COVER
GROUND
BEHIND FRONT
LEFT ROLLER
+5V DC
BOARD VIEW
BOARD-MOUNTED
AMBIENT THERMISTOR
J9
+5V DC
2 4
J1
AT1 & MB1
3
BACK VIEW
AT1
9
7
1
1
LH1
MB2
3
9
1
7
2
4
3
1
1
3
RH1
9
9
3
7
7
1
5
2
4
1 3
2
2
1
1
1
RL3
RL6
11
12
1
2
J8
AMBIENT
TEMP
SENSOR
RL8
U2 RL4
J4
1
1
RL7
J6
1
RL9
J3
J11
RL2
RL5
1
LATCH
1 4
RL1
J2
5
CATCH
1
MC1
3
MB2
GRN/YEL
RIGHT DOOR
FLANGE
1
MB1
VARIABLE SPEED
COMPRESSOR/ INV.
12 VDC
GRN/YEL
GRN/YEL
FRONT INSIDE
VIEW
MC1
POWER
CONTROL SIGNAL
RED/BLK
BLK/WHT
+12V DC
1
J8
2
LH1
LINE
+5V DC
12
J5
8
YEL/PNK
YEL/PNK
CAB. GROUND
+12V DC
5
6
J5
3
4
RED/YEL
BRN/YEL
NEUTRAL
+5V DC
11
12
BLK/WHT
2
AT1
RH1
RED/WHT
BRN/WHT
PIN 6
12V DC
DAMPER
MOTOR
YEL/WHT
MB1
RED
COMPRESSOR
CONTROL SIGNAL
COMM.
3
4
5
6
1
J4
2
9
WHT/RED
WHT/GRN
WHT/GRN
WHT/RED
WHT/RED
4
WHT/GRN 3
2
WHT/RED 1
WHT/RED
LED
GRY/BLK
WHT/GRN
WHT/GRN
FZ-2
GRY/BLK
LT. BLU
BLK
GND
5
6
7
J6
8
11
12
GRY/YEL
COMPRESSOR
GROUND
PIN 1
4
3
2
1
WHT/BRN
WHT/BRN
WHT/BLU
WHT/BLU
BLK
AC SIDE
PIN 4
4
3
2
1
WHT/BRN
WHT/BRN
WHT/BLU
WHT/BLU
DC SIDE
PIN 5
4
3
2
1
WHT/BRN
WHT/BRN
WHT/BLU
WHT/BLU
BASE PLATE
GROUND
RIBBED
(NEUTRAL)
NON-RIBBED
(LINE)
POWER CORD
J7
1
J5
Wire Diagram A06742201