Frigidaire | FFTA0833S1 | FFTA0833S1 0116 EN | Frigidaire FFTA0833S1 FFTA0833S1 0116 EN

Home Comfort
FFTA0833S1
Through-The-Wall
Air Conditioner
Product Dimensions
Height
14-1/2"
Width
24"
Depth
20-1/2"
More Easy-To-Use Features
Sleep Mode
With Sleep Mode, the temperature
gradually increases a few degrees over
the evening, saving energy and creating
a comfortable environment during the
evening hours.
Remote Control
Offers you the flexibility to control the
temperature and fan speed from anywhere
in the room.
Effortless™ Clean Filter
Our antibacterial filter reduces bacteria,
room odors and other airborne particles
for a healthier, more comfortable
environment.
Power Cord
Comes with an extra long three-prong cord
— makes extension cords unnecessary.
Effortless™ Restart
Automatically resumes operating at its
previous settings when power is restored
to your unit.
Clean Filter Alert
Alert notifies you when your filter needs
to be cleaned so you don’t have to keep
track of it yourself.
Signature Features
Effortless™ Remote
Temperature Control
Remote control thermostat precisely
maintains preset room temperature, so
you can remain comfortable at all times.
Programmable 24-Hour
On/Off Timer
With the 24-Hour On/Off Timer, you
can ensure your home will be cool and
comfortable when you want it to be
without having to worry about running
up your utility bills. The built-in timer
allows you to preset the unit to turn on
and off in half-hour increments.
Ready-Select® Controls
Easily select options with the touch of
a button.
Energy Saver Mode
Reduce your utility bills in this mode. It
cools similarly to central air, with the unit
turning on and off at different intervals
to ensure the room temperature stays at
the set temperature.
ENERGY STAR®
Performance
BTUs
Cool
8,000
Multi-Speed Fan
Features three different fan speeds, for
more cooling flexibility.
frigidaire.com
Home Comfort
FFTA0833S1
Through-The-Wall Air Conditioner
Performance
BTU (Cool)
8,000
Dehumidification (Pints / Hour)
1.8
Cool Area (Up To Sq. Ft.)
350
Energy Efficiency Ratio
10.6
Electrical
Volts
115
Amps (Cool)
7.0
Watts (Cool)
750
Length of Power Cord (Min. / Max.)
6' / 6.5'
Plug Type (NEMA)
LCDI (5-15P)
Features
RAC Through-The-Wall Models (18" Sleeve Kit EA
Frigidaire Baseline
Electronic Controls
Ready-Select® Controls
Fan Speeds (Cool / Fan)
3/3
Low Voltage Start-Up
Yes
Auto Cool Function
Yes
Energy Saver Mode
Yes
Sleep Mode
Yes
Filter Check
Yes
24-Hour On / Off Timer
Yes
A
B
C
D
Clean Air Ionizer
Remote Control
Full-Function Remote T’Stat
Air CFM (High / Med / Low)
270 / 235 / 202
Air Direction Control
4-Way
Fresh Air / Exhaust Vent / Closed
No / No / Yes
Filter Type
Antibacterial Mesh
Filter Access
Slide-Out
Through-The-Wall 18" Sleeve Kit
(PN # EA108T)
Outside closure panel
Slide-Out Chassis
Warranty1
Yes
Optional Accessories
Through-The-Wall 18" Sleeve Kit
PN # EA108T
Trim Kit (for larger existing sleeve)
PN # EA120T
Architectural-Style
Exterior Louvered Grille
PN # EA109T
Adjustable
mounting
brackets
Certifications
ENERGY STAR®
Yes
Performance
AHAM
Locking clip
Specifications
Refrigerant
R410a
Shipping Weight (Approx.)
76 Lbs.
Inside
closure panel
Sleeve-to-unit seal
Building construction support
Warranty 5 year sealed system / 1 year full parts and labor.
1
Plug Type (NEMA)
5-15P
NOTE: For planning purposes only. Always consult local and national electric codes.
Refer to Product Installation Guide for detailed installation instructions on the web at frigidaire.com.
Product Dimensions
Sleeve Cutout Dimensions
A - Height
14-1/2"
Height
15-5/8"
B - Width
24"
Width
25-15/16"
C - Depth
20-1/2"
D - Max. Wall Thickness
18"
Accessories information available
on the web at frigidaire.com
USA • 10200 David Taylor Drive • Charlotte, NC 28262 • 1-800-FRIGIDAIRE • frigidaire.com
CANADA • 5855 Terry Fox Way • Mississauga, ON L5V 3E4 • 1-800-265-8352 • frigidaire.ca
FFTA0833S1 01/16
© 2016 Electrolux Home Products, Inc.
Specifications
subject to change.
Frigidaire Baseline
Home Comfort
FFTA0833S1
Through-The-Wall Air Conditioner
Through-The-Wall Installation
Wall (thickness)
14 1/2"
18"
max.
20 /2"
1
24"
Through-The-Wall 18" Sleeve Kit
(PN # EA108T)
Outside closure panel
Wall
Adjustable
mounting
brackets
Locking clip
Plug Type (NEMA)
5-15P
Inside
closure panel
Sleeve-to-unit seal
Building construction support
Home Comfort Specifications
Replacement Installation
• Product Shipping Weight (approx.) – 76 Lbs.
• An electrical supply with grounded three-prong receptacle is
required. The power supply circuit must be installed in accordance
with current edition of National Electrical Code (ANSI/NFPA 70)
and local codes & ordinances.
• Voltage Rating – 115V / 60 Hz / 15 Amps
• Amps @ 115 Volts = 7.0 Amps
• Recommended Circuit Breaker – 15 Amps
• Unit equipped with 115V 3-wire power supply cord, NEMA plug type
5-15P, approximately 72" long.
• Unit’s increased performance characteristics result from two rear
intakes. For unit to operate at maximum efficiency, carefully follow
complete, detailed new or replacement installation instructions
provided in Product Installation Guide on web.
• Unit requires rearward slope when installation is complete, to allow
condensate to drain from rear of sleeve.
• When replacing existing air conditioner with new unit, refer to
Product Installation Guide on web to identify existing wall-sleeve
manufacturer and size compatibility. If proper installation and slope
are suspect, then correct installation of Frigidaire® Through-The-Wall
18" Sleeve Kit PN # EA108T recommended.
• Use of existing wall sleeve to mount new unit requires original sleeve
be in sound structural condition with rear grille that attaches securely,
or rear flange that serves as stop for unit.
• Preferable installation option, for increased efficiency and possibility
of drafts reduced, requires existing rear grille (mounted to sleeve) be
replaced with new unit’s rear air-directional louvered grille (provided
in accessory kit, shipped with unit). Non-preferable installation option
of directly mounting rear louvered grille to unit can be considered,
requiring grille be mounted to unit prior to sleeve installation.
• Existing decorative exterior grille may be left in place, provided that
proper air-directional rear louvered grille is installed.
• For installation into larger existing sleeve, optional Trim Kit
PN # EA120T available.
New Installation
• For new installation, Frigidaire® Through-The-Wall 18" Sleeve Kit
PN # EA108T available. Recommended for proper installation.
• Through-the-wall installation requires 18" maximum wall thickness.
• For energy-saving purposes, install unit in shady location, preferably
a northern exposure; and do not block airflow inside with blinds,
curtains or furniture; or outside with shrubs, enclosures or other
buildings.
Note: For planning purposes only. Refer to Product Installation Guide
on the web at frigidaire.com for detailed instructions.
Optional Accessories
• Through-The-Wall 18" Sleeve Kit – (PN # EA108T).
• Trim Kit (for larger existing sleeve) – (PN # EA120T).
• Architectural-Style Exterior Louvered Grille – (PN # EA109T).
USA • 10200 David Taylor Drive • Charlotte, NC 28262 • 1-800-FRIGIDAIRE • frigidaire.com
CANADA • 5855 Terry Fox Way • Mississauga, ON L5V 3E4 • 1-800-265-8352 • frigidaire.ca
FFTA0833S1 01/16
© 2016 Electrolux Home Products, Inc.
Specifications
subject to change.
Download PDF

advertising