DUCTLESS SPLIT SYSTEMS ALL NEW LINE THE EXPERTS IN ROOM AIR CONDITIONING ALL-NEW, 16.0 SEER wall-mounted ductless Fully-featured inverter line at attractive price points ® Comfort & Convenience • All models offer heating and cooling capabilities Inverter variable capacity advantages • Inverter technology is more energy efficient and can self-adjust capacity to match cooling needs Inverter technology varies the compressor speed and the outdoor and indoor fan speeds, eliminating constant compressor start-ups/ shut-downs that traditional systems require to maintain the temperature set point. The system can adjust capacity and cooling output to provide only the amount of cooling needed at a given time. The result is optimal comfort with low energy costs. Zero duct loss The DOE reports that ducted systems lose an average of 25-40% in performance due to leaks, cracks or disconnections in ductwork. No ductwork means that ductless systems do not experience duct loss, saving energy and money. 115 volt MM09YJ 9000 Btu cooling 9800 Btu heating Superior to traditional HVAC systems TRADITIONAL SYSTEM INVERTER SYSTEM At initial start up, fixed capacity system slowly reaches the set temperature. At initial start up, utilizes variable capacity to quickly reach the set temperature. Complete shutdown once set temperature is achieved. Reduces capacity as set temperature is achieved. No dirty air ducts Temperature rises until 2nd system start up. Now there’s no need to clean dirty air ducts that can harbor dust, germs and allergens that are eventually blown into your home or office. System works at full capacity to again reach set temperature. System cycles on and off continually to maintain the set temperature. MM12YJ 11800 Btu cooling 13000 Btu heating • Multiple operating modes including: AUTO, COOL, DRY (dehumidification), FAN ONLY and HEAT • TURBO mode operates the unit at maximum performance to quickly bring the room to set temperature • 4 fan speeds heating or cooling: HIGH, MEDIUM, LOW, “QUIET”, plus AUTO-FAN • Continuous ‘Air Sweep’ UP & DOWN • LCD remote • 24-hour timer and sleep timer • Auto-restart after power interruptions Variable capacity maintains set temperature keeping space comfortable with reduced energy consumption. • Auto-shut flaps close when unit is off for a sleeker appearance • Washable, long-life, antimicrobial air filters • 230 volt models provide cooling in outdoor temperatures down to 5˚ F • 4 different transmitter codes to prevent unintentional interference with nearby units 230/208 volt MM18YJ 18000 Btu cooling 23000 Btu heating Continuous Air Sweep The indoor unit’s up/down air swing quickly disperses cool air to all four corners of the room to provide comfort throughout the room within a few minutes. MM24YJ 22000 Btu cooling 26600 Btu heating Floating Air Ductless Split Systems 2014 Mid-Tier PERFORMANCE RATINGS SYSTEM MODEL NO. MM09YJ MM12YJ MM18YJ MM24YJ INDOOR MODEL MWM09Y1J MWM12Y1J MWM18Y3J MWM24Y3J OUTDOOR MODEL MRM09Y1J MRM12Y1J MRM18Y3J MRM24Y3J 11800 18000 22000 CAPACITY COOLING (RATED) Btu 9000 CAPACITY COOLING MIN - MAX Btu 3500~11000 3300~12500 4500~21000 6400~24000 COOLING AMPS 9.00 15.00 7.85/7.10 11.50/10.50 HEATING AMPS 9.50 15.5 10.60/11.80 12.80/13.00 SENSIBLE HEAT RATIO 0.79 0.73 0.77 0.77 Btu 9800 13000 19200 24200 CAPACITY HEATING MIN - MAX Btu 2500~11000 3400~13500 4000~23000 4100~26600 CAPACITY HEATING (RATED) @ 17°F Btu 5400 8500 12000 18600 HSPF 8.6 8.6 8.5 8.5 SEER 16.0 16.0 16.0 16.0 EER 12.0 9.4 11.0 10.0 Y N N N Pts/h 1.69 2.96 3.80 4.50 CAPACITY HEATING (RATED) @ 47°F ENERGY STAR MOISTURE REMOVAL AIRFLOW (HIGH/MED/LOW/QUIET) CFM 330/277/224/188 341/288/235/200 471/400/330/271 588/441/306/206 SOUND RATING - INDOOR (HIGH/MED/LOW/QUIET) dB-A 41/37/35/32 43/39/35/32 48/43/38/34 49/43/39/34 SOUND RATING - OUTDOOR dB-A 53 55 56 53 °F 5-75 5-75 -4-75 19-75 °F 32*-113 32*-113 5-118 5-115 67 113 146 198 208/230/60/1 OPERATING RANGE (HEATING) OPERATING RANGE (COOLING) EST. YEARLY OPERATING COST U.S. $ ELECTRICAL DATA POWER SOURCE V/Hz/Phase 115/60/1 115/60/1 208/230/60/1 MIN. AMPACITY A 13 15 15 16 COOLING WATTS W 750 1260 1620 2200 HEATING WATTS W 830 1320 2400 2800 MAX. TD FUSE/BREAKER A 20 25 25 25 REFRIGERATION SYSTEM REFRIGERANT COMPRESSOR TYPE CONNECTIONS R410A R410A R410A R410A Inverter Inverter Inverter Inverter Flare Flare Flare Flare LIQUID LINE O.D. in 1/4” 1/4” 1/4” 1/4” SUCTION LINE O.D. in 3/8” 3/8” 1/2” 1/2” oz. 35.3 35.3 45.8 54.7 FACTORY PRECHARGE ft 24.6 24.6 24.6 24.6 MAX. LINE LENGTH ft 65 65 82 82 MAX. HEIGHT DIFFERENCE ft 32 32 32 32 REFRIGERANT CHARGE DIMENSIONS & WEIGHT INDOOR UNIT in 33 5/16”×13 9/16”×10 7/8” 33 5/16”×13 9/16”×10 7/8” NET WEIGHT lbs 19 19 26 33 SHIPPING WEIGHT lbs 25 25 35 44 LXWXH 37 5/16”×15 1/8”×12 3/16” 42 3/8”×15 11/16”×12 15/16” OUTDOOR UNIT in 34 11/16”×14 5/16”×23 7/16” 34 11/16”×14 5/16”×23 7/16” 40 9/16”×18 1/16”×29 9/16” 40 9/16”×18 1/16”×29 9/16” LXWXH NET WEIGHT lbs 68 68 106 115 SHIPPING WEIGHT lbs 77 77 117 126 TOTAL NET WEIGHT lbs 87 87 132 148 TOTAL SHIPPING WEIGHT lbs 102 102 152 170 *Capacity is reduced as 32 degrees Fahrenheit is approached. Due to continuing research in new energy-saving technology, specifications are subject to change without notice. Friedrich Air Conditioning Co. l 10001 Reunion Place, Suite 500 l San Antonio, TX 78216 l 877.599.5665 www.friedrich.com Commercial_Floating_Air_Ductless_Brochure_2014 Printed in USA
advertising