Friedrich | C24YJ | 2014 Floating Air Ductless Brochure (PDF) | Friedrich C24YJ 2014 Floating Air Ductless Brochure (PDF)

DUCTLESS
SPLIT SYSTEMS
ALL NEW LINE
THE EXPERTS IN ROOM AIR CONDITIONING
ALL-NEW, 16.0 SEER wall-mounted ductless
Fully-featured inverter line at attractive price points
®
Comfort & Convenience
• All models offer heating and
cooling capabilities
Inverter variable capacity advantages
• Inverter technology is more
energy efficient and can
self-adjust capacity to match
cooling needs
Inverter technology varies the compressor
speed and the outdoor and indoor fan speeds,
eliminating constant compressor start-ups/
shut-downs that traditional systems require to
maintain the temperature set point.
The system can adjust capacity and cooling
output to provide only the amount of cooling
needed at a given time. The result is optimal
comfort with low energy costs.
Zero duct loss
The DOE reports that ducted systems lose an
average of 25-40% in performance due to leaks,
cracks or disconnections in ductwork.
No ductwork means that ductless systems do not
experience duct loss, saving energy and money.
115 volt
MM09YJ
9000 Btu cooling
9800 Btu heating
Superior to traditional HVAC systems
TRADITIONAL SYSTEM
INVERTER SYSTEM
At initial start up, fixed capacity
system slowly reaches the set
temperature.
At initial start up, utilizes
variable capacity to quickly
reach the set temperature.
Complete shutdown once set
temperature is achieved.
Reduces capacity as set
temperature is achieved.
No dirty air ducts
Temperature rises until 2nd
system start up.
Now there’s no need to clean dirty air ducts that
can harbor dust, germs and allergens that are
eventually blown into your home or office.
System works at full capacity to
again reach set temperature.
System cycles on and off
continually to maintain the set
temperature.
MM12YJ
11800 Btu cooling
13000 Btu heating
• Multiple operating modes
including: AUTO, COOL, DRY
(dehumidification), FAN ONLY
and HEAT
• TURBO mode operates the unit
at maximum performance to
quickly bring the room to set
temperature
• 4 fan speeds heating or
cooling: HIGH, MEDIUM, LOW,
“QUIET”, plus AUTO-FAN
• Continuous ‘Air Sweep’ UP &
DOWN
• LCD remote
• 24-hour timer and sleep timer
• Auto-restart after power
interruptions
Variable capacity maintains
set temperature keeping space
comfortable with reduced
energy consumption.
• Auto-shut flaps close when unit
is off for a sleeker appearance
• Washable, long-life,
antimicrobial air filters
• 230 volt models provide cooling
in outdoor temperatures down
to 5˚ F
• 4 different transmitter codes
to prevent unintentional
interference with nearby units
230/208 volt
MM18YJ
18000 Btu cooling
23000 Btu heating
Continuous Air Sweep
The indoor unit’s up/down air swing quickly
disperses cool air to all four corners of the
room to provide comfort throughout the
room within a few minutes.
MM24YJ
22000 Btu cooling
26600 Btu heating
Floating Air Ductless Split Systems
2014 Mid-Tier PERFORMANCE RATINGS
SYSTEM MODEL NO.
MM09YJ
MM12YJ
MM18YJ
MM24YJ
INDOOR MODEL
MWM09Y1J
MWM12Y1J
MWM18Y3J
MWM24Y3J
OUTDOOR MODEL
MRM09Y1J
MRM12Y1J
MRM18Y3J
MRM24Y3J
11800
18000
22000
CAPACITY COOLING (RATED)
Btu
9000
CAPACITY COOLING MIN - MAX
Btu
3500~11000
3300~12500
4500~21000
6400~24000
COOLING AMPS
9.00
15.00
7.85/7.10
11.50/10.50
HEATING AMPS
9.50
15.5
10.60/11.80
12.80/13.00
SENSIBLE HEAT RATIO
0.79
0.73
0.77
0.77
Btu
9800
13000
19200
24200
CAPACITY HEATING MIN - MAX
Btu
2500~11000
3400~13500
4000~23000
4100~26600
CAPACITY HEATING (RATED) @ 17°F
Btu
5400
8500
12000
18600
HSPF
8.6
8.6
8.5
8.5
SEER
16.0
16.0
16.0
16.0
EER
12.0
9.4
11.0
10.0
Y
N
N
N
Pts/h
1.69
2.96
3.80
4.50
CAPACITY HEATING (RATED) @ 47°F
ENERGY STAR
MOISTURE REMOVAL
AIRFLOW (HIGH/MED/LOW/QUIET)
CFM
330/277/224/188
341/288/235/200
471/400/330/271
588/441/306/206
SOUND RATING - INDOOR (HIGH/MED/LOW/QUIET)
dB-A
41/37/35/32
43/39/35/32
48/43/38/34
49/43/39/34
SOUND RATING - OUTDOOR
dB-A
53
55
56
53
°F
5-75
5-75
-4-75
19-75
°F
32*-113
32*-113
5-118
5-115
67
113
146
198
208/230/60/1
OPERATING RANGE (HEATING)
OPERATING RANGE (COOLING)
EST. YEARLY OPERATING COST
U.S. $
ELECTRICAL DATA
POWER SOURCE
V/Hz/Phase
115/60/1
115/60/1
208/230/60/1
MIN. AMPACITY
A
13
15
15
16
COOLING WATTS
W
750
1260
1620
2200
HEATING WATTS
W
830
1320
2400
2800
MAX. TD FUSE/BREAKER
A
20
25
25
25
REFRIGERATION SYSTEM
REFRIGERANT
COMPRESSOR TYPE
CONNECTIONS
R410A
R410A
R410A
R410A
Inverter
Inverter
Inverter
Inverter
Flare
Flare
Flare
Flare
LIQUID LINE O.D.
in
1/4”
1/4”
1/4”
1/4”
SUCTION LINE O.D.
in
3/8”
3/8”
1/2”
1/2”
oz.
35.3
35.3
45.8
54.7
FACTORY PRECHARGE
ft
24.6
24.6
24.6
24.6
MAX. LINE LENGTH
ft
65
65
82
82
MAX. HEIGHT DIFFERENCE
ft
32
32
32
32
REFRIGERANT CHARGE
DIMENSIONS & WEIGHT
INDOOR UNIT
in
33 5/16”×13 9/16”×10 7/8”
33 5/16”×13 9/16”×10 7/8”
NET WEIGHT
lbs
19
19
26
33
SHIPPING WEIGHT
lbs
25
25
35
44
LXWXH
37 5/16”×15 1/8”×12 3/16” 42 3/8”×15 11/16”×12 15/16”
OUTDOOR UNIT
in 34 11/16”×14 5/16”×23 7/16” 34 11/16”×14 5/16”×23 7/16” 40 9/16”×18 1/16”×29 9/16” 40 9/16”×18 1/16”×29 9/16”
LXWXH
NET WEIGHT
lbs
68
68
106
115
SHIPPING WEIGHT
lbs
77
77
117
126
TOTAL NET WEIGHT
lbs
87
87
132
148
TOTAL SHIPPING WEIGHT
lbs
102
102
152
170
*Capacity is reduced as 32 degrees Fahrenheit is approached.
Due to continuing research in new energy-saving technology, specifications are subject to change without notice.
Friedrich Air Conditioning Co. l 10001 Reunion Place, Suite 500 l San Antonio, TX 78216 l 877.599.5665
www.friedrich.com
Commercial_Floating_Air_Ductless_Brochure_2014
Printed in USA
Download PDF

advertising