Friedrich | C24YJ | 2014 Ductless Brochure (PDF) | Friedrich C24YJ 2014 Ductless Brochure (PDF)

DUCTLESS
SPLIT SYSTEMS
ALL NEW LINE
FOR 2014
THE EXPERTS IN ROOM AIR CONDITIONING
The Next Generation
of Ductless Split Systems
Three indoor unit types.
WALL-MOUNTED
Cool only and heat pump models
All of the advantages of ductless systems and
Friedrich quality.
SU
PERIOR
25.0 SEER
EF
FICIENC
Y
Friedrich's highest
energy efficiencies
ever. Up to 25.0 SEER
ENERGY STAR® models
All Friedrich ductless models exceed the
federal 13.0 SEER requirements.
Of the 146 total possible single and
multizone configurations, 102 models
meet ENERGY STAR® published
minimums with SEERS up to 25.0 and
EERs up to 14.0.
Inverter variable capacity
advantages
Inverter technology allows each system
to adjust capacity and cooling output
to provide only the amount of cooling
needed at a given time. For example,
an 18000 Btu system will operate even
more efficiently at 15500 Btu or less if
that's all that’s needed, reducing energy
consumption and improving comfort.
Optimized airflow
The indoor unit's 4-way air swing quickly
disperses cool air to all four corners of
the room to provide comfort throughout
the room within a few minutes. The
'Air Burst' feature moves air at an even
higher speed for rapid cooling.
Protects the outdoor coil against
deterioration and extends the life
of the unit especially in harsh
coastal environments.
*Ductless wall-mounted and ceiling cassette models
2
Zero duct loss
The DOE reports that ducted systems
lose an average of 25-40% in
performance due to leaks, cracks or
disconnections in ductwork.
No ductwork means that ductless
systems do not experience duct loss,
saving energy and money.
Zone cooling flexibility
Independently condition up to (4)
separate zones using only a single
outdoor unit. Achieve the ultimate in
comfort and energy control by cooling or
heating only the zones that are in use.
And, because each zone is independent
of the others, comfort settings can vary.
No dirty air ducts*
Now there’s no need to clean dirty air
ducts that can harbor dust, germs and
allergens that are eventually blown into
your home or office.
CEILING CASSETTE
CONCEALED DUCT
Heat pumps
Heat pumps
Friedrich has up to 131 multizone configurations utilizing wall-mounted,
ceiling cassette and concealed duct models.
Zone Cooling and Heating
Occupants have the ability to set
the temperature of each zone
to their preferred comfort level.
The system will run as needed to
maintain desired temperature.
Occupants may also turn off units
in unoccupied rooms without
affecting other zones.
70 °
That’s the beauty– and efficiency of
a Friedrich multizone system.
Enjoy the flexibility
to mix and match
wall-mounted,
ceiling cassette
and concealed duct
systems to fit your
application.
72 °
OFF
74 °
3
No other system matches the efficiency and performance of
Friedrich's Precision Inverter™
CONVENTIONAL SYSTEMS run at a single capacity,
turning on and off to reach the desired set point.
This means they run at full speed each time, resulting
in high energy consumption.
Hz
100
95
90
85
80
75
70
65
60
55
50
45
40
35
30
25
20
15
10
5
Hz
100 % Capacity
0
Capacity
Wasted Energy
Conventional On/Off System - 1 Optimized Point
20
40
60
80
100
TYPICAL INVERTER SYSTEMS make changes in 7Hz
increments allowing the unit to run at variable speeds,
delivering a more precise heating-cooling solution.
Hz
100
95
90
85
80
75
70
65
60
55
50
45
40
35
30
25
20
15
10
5
0
Capacity
4
7 Hz Increments
Wasted Energy
Typical Inverter AC - 11 Optimized Points
20
TWO-STAGE AIR CONDITIONERS won’t significantly reduce
your energy use. These units only run at 2 speeds, 50% and
100%, also resulting in high energy consumption.
40
60
80
100
100
95
90
85
80
75
70
65
60
55
50
45
40
35
30
25
20
15
10
5
100 % Capacity
Wasted Energy
50 % Capacity
Wasted Energy
0
Capacity
Two-Stage System (Low/High) - 2 Optimized points
20
40
60
80
100
Friedrich’s Precision Inverter™ accomplishes better
energy efficiency by using 1Hz increments.
This allows the unit to produce only the output necessary to reach the desired temperature.
The result is optimal performance and increased energy efficiency.
Inverter technology varies the
compressor, the outdoor and the
indoor fan speeds, eliminating constant
compressor start-ups/shut-downs that
traditional systems require to maintain
the set temperature.
This is especially beneficial in
multizone
systems
PRECISION
where room
temperature
set points
vary and
some indoor units may be turned off in
unoccupied rooms.
Each system can adjust capacity and
cooling output to provide only the
amount of cooling needed at a given
time.
The result is optimal comfort with low
energy costs.
Hz
100
95
90
85
80
75
70
65
60
55
50
45
40
35
30
25
20
15
10
5
0
Capacity
Friedrich Precision Inverter
80 Optimized Points
1 Hz Increments
Almost No Energy Wasted
20
40
60
80
100
The Advantages of Friedrich's Precision Inverter System
TRADITIONAL SYSTEM
INVERTER SYSTEM
At initial start up, fixed capacity
system slowly reaches the set
temperature.
At initial start up, utilizes
variable capacity to quickly
reach the set temperature.
Complete shutdown once set
temperature is achieved.
Reduces capacity as set
temperature is achieved.
Temperature within the space
rises until 2nd system start up.
System works at full capacity to
again reach set temperature.
System cycles on and off
continually to maintain the set
temperature.
Variable capacity maintains
set temperature keeping space
comfortable with reduced
energy consumption.
5
Attractive and high efficiency options for
cooling and heating residential and light
commercial spaces.
Wall-mounted
models mount
high on the wall.
The attractive,
neutral finish
blends well with
just about any
decor.
6
Residential
Applications
Commercial
Applications
• Room additions/renovations
• Hotels and other lodging
• Homes without ductwork
• Computer rooms/server rooms
• Bedrooms and family rooms
• Restaurant kitchen and prep areas
• Garage workshops
• Offices in warehouse spaces
• Sunrooms
• Storage facilities
• Guest quarters
• Buildings where security concerns
prevent the use
of window units
• Wine cellars
• Internal areas without exterior
wall access
Indoor units can be
used individually
or as part of a
multizone system
to condition
multiple spaces or
a large area.
7
Features you'll find with Friedrich Ductless Systems:
System Type
Wall-mounted
Single Zone
Wall-mounted
Multizone
Cassette
Single Zone
Cassette
Multizone
Concealed Duct
Single Zone
Concealed Duct
Multizone
Installation
Wall
Wall
Ceiling
Ceiling
Ceiling
Ceiling
Cool only
Y
N
N
N
N
N
Heat pump
Y
Y
Y
Y
Y
Y
115 volt models
Y
N
N
N
N
N
Inverter compressor
Y
Y
Y
Y
Y
Y
Up to 25.0
Up to 21.7
Up to 19
Up to 16.5
Up to 17.6
Up to 16.5
Auto changeover
Y
N
Y
N
Y
N
Low ambient operation*
Y
Y
Y
Y
Y
Y
24- Hr. Programmable timer
Y
Y
Y
Y
N
N
Remote control
Y
Y
Y
Y
N
N
Wall controller option
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Auto restart when power is
interrupted
Y
Y
Y
Y
Y
Y
Continuous ‘Air Sweep”
Y
Y
Y
Y
N
N
Washable, antimicrobial air filters
Y
Y
Y
Y
Y
Y
Auto shut flaps when unit is off
Y
Y
Y
Y
N
N
6/6/6
6/6/6
4/5/4
4/5/4
N
N
SEER
7-Day Programmability (with wall
control)
Louver Position (Fan/Cool/Heat)
*Refer to specification tables for low ambient capabilities.
Powerful airflow for faster heating and cooling.
Optimum air flow
Air is directed downward in heating mode and
angled upward during cooling mode so the
room feels more comfortable, faster.
Large fans
Powerful fans move the air across the roomup to 39 feet away. That means faster cooling
and heating and you feel comfortable sooner
no matter where you are in the room.
8
Features you'll find with Friedrich Ductless Systems:
DiamonGold Advanced Corrosion
Protection™
Protects the outdoor coil against deterioration
and extends the life of the unit especially in
harsh coastal environments.
Auto dry
Auto restart
Auto restart function allows system to resume
with previous settings in the event of a power
shutdown. (Power supply must be restored)
Auto changeover
Indoor blower runs to dry out indoor coil after
system is shutdown.
When this function is selected system will
adjust between Cooling and Heating mode
based on room temperature
Surge cool/heat
Built-in low ambient standard
Allows quick cooling/heating. In this mode the
unit will operate at 100% for 30 minutes to
cool/heat the room rapidly.
Allows unit’s operation down to 14ºF in
cooling mode.
Dehumidifying mode
The system will adjust set point for maximum
dehumidification.
4-Way auto swing
Louvers will automatically move up/down
and left /right to maintain a uniform room
temperature.
Friedrich's ductless line incorporates a cross-flow fan and
a low vibration compressor to provide ultra quiet operation.
Conventional On/Off
Ultra quiet cross-flow fan
The cross-flow design of the indoor fan
creates an ultra quiet, yet powerful air
flow into the room.
Low vibration, twin-rotary
compressor
Friedrich's twin-rotary compressor has a
unique design that reduces vibration for
reduced sound levels outdoors.
BLDC fan motor
With accurate speed control that makes
the electrical and mechanical operation
smoother.
Friedrich Low Fan Speed
35dB(A)
24dB(A)
Friedrich Sleep Mode
17dB(A)
17
24
35
38
Recording Studio
Concert Hall
Library
Conference Room
9
EASE OF INSTALLATION
New ductless line with convenient installation features
that will get your ductless running in no time.
UNIQUE MOUNTING BRACKET
A SET OF
16 INCH ON CENTER HOLES
16" on Center
The hanging bracket comes with a set of holes
that are placed 16” apart from each other to
help you attach the bracket securely to "16 on
center" wall studs.
Level-Line Ledges
Incorporated “Level-Line Ledges” ensure a
straight wall mount and frees both hands for
an easy single-person installation.
Tape Measure Assist
The integrated “blade grip” securely keeps
measuring tape in place. The ”blade grip”
gives you a helping hand when installing the
bracket to the wall.
Wall Standoff Bracket
The clip keeps sufficient space between the unit
and the wall creating more room for installation.
Spacious Tubing Area
Ample space was created to facilitate tubing
installation and placement.
Low Installation Access Panel
By lowering the access panel to eye-level we
have created a hassle-free access to electrical
connections.
Secure Grip Screws
"Grip Screws" firmly secure wall-mounted unit to
wall bracket providing a stable setup.
10
OPTIONAL ACCESSORIES
Refrigeration Line Sets
USED WITH
Length
Ft.
Liquid
Suction
Kit#
15’
1/4”
3/8”
T32150
35’
1/4”
3/8”
T32350
9000 and 12000 Btu indoor units
18000 BTU indoor units
24000, 30000 and 36000 Btu
indoor units
15’
1/4”
1/2”
T42150
35’
1/4”
1/2”
T42350
15’
3/8”
5/8”
T53150
35’
3/8”
5/8”
T53350
Low Ambient Wind Baffle Kit
Wind baffle allows operation down to O degrees Fahrenheit
(Available for Wall-Mounted Single Zone)
WIND
BAFFLE
USED WITH
DLAWB1
9000 - 12000 Btu wall-mounted single zone models
DLAWB2
18000 - 36000 Btu wall-mounted single zone models
Thermostat
DWC1-Wired Wall Thermostat (Available for all models)
Ceiling Cassette Grilles
Required decorative grille for ceiling cassette models
DECORATIVE
GRILLE
USED WITH
DCG1218
MC12Y3JM, MC18Y3JM - 12000 and 18000 Btu models
DCG2436
MC24Y3J , MC36Y3J- 24000 and 36000 Btu models
Friedrich's Ductless Split systems are compatible with aftermarket drain pumps and condensate sensors.
For more information visit the following sites:
Condensate Pumps
Rectorseal/Aspen Pumps: http://airtec.rectorseal.com/pumpselector.
Condensate Sensors
Rectorseal, Safe-T-Switch® SS610E: www.rectorseal.com
Aqua guard, AG-9300-U: www.rctus.com/product
Adapter
Adapter part number 67270018 is available through Friedrich parts distributors.
All R410A models have 1/2”-20 UNF (5/16” SAE) X 1/4” SAE thread per inch charging and vacuuming ports.
An adapter must be used for ¼” gauges.
11
Single Zone
WALL-MOUNTED COOL ONLY
9000-24000 Btu. Cool only models with features for convenient operation,
care-free comfort and years of dependability.
Features
• Inverter technology (variable speed compressor)
• High efficiency for low operating cost
• DiamonGold Advanced Corrosion Protection™
• Auto dry indoor coil
• Cooling/Fan mode
• Surge cool
• Natural air flow
• 4-Way auto swing
• Ultra quiet operation
• Sleep mode
• Dehumidifying mode
• Auto restart
• Built-in low ambient standard, down to 14ºF
(Cooling Mode)
• 24-hour on-off timer
• Condensate sensor connection
• Multiple ease of installation features (see p.10)
MW18C3J, MW24C3J
MW09C1J, MW12C1J
MR09C1J, MR12C1J
MR18C3J
MR24C3J
PRECISION
12
SPECIFICATIONS
PERFORMANCE RATINGS
SYSTEM MODEL NO.
INDOOR MODEL
OUTDOOR MODEL
SPECIFICATIONS
CAPACITY COOLING (RATED)
CAPACITY COOLING (MIN~MAX)
CAPACITY HEATING (RATED)
CAPACITY HEATING (MIN~MAX)
COOLING AMPS
HEATING AMPS
SENSIBLE HEAT RATIO
SEER
EER
HSPF
ENERGY STAR
MOISTURE REMOVAL
AIRFLOW (QUIET, LOW, MED, HIGH)
SOUND RATING - INDOOR
SOUND RATING - OUTDOOR
OPERATING RANGE WIND BAFFLE)
OPERATING RANGE (HEATING)
EST. YEARLY OPERATING COST
ELECTRICAL DATA
POWER SOURCE
MINIMUM AMPACITY
COOLING WATTS
MAX. TD FUSE/BREAKER
POWER AND COMMUNICATION CABLE
REFRIGERATION SYSTEM
REFRIGERANT
COMPRESSOR TYPE
CONNECTIONS
LIQUID LINE O.D.
SUCTION LINE O.D.
FACTORY PRECHARGE
REFRIGERANT CHARGE
MIN./MAX. LINE LENGTH
MAX. HEIGHT DIFFERENCE
DIMENSIONS & WEIGHT
INDOOR UNIT
WXHXD
NET WEIGHT
SHIPPING WEIGHT
OUTDOOR UNIT
WXHXD
NET WEIGHT
SHIPPING WEIGHT
TOTAL NET WEIGHT
TOTAL SHIPPING WEIGHT
Single Wall Mounted - Cool Inv
9k
M09CJ
MW09C1J
MR09C1J
12k
M12CJ
MW12C1J
MR12C1J
18k
M18CJ
MW18C3J
MR18C3J
24k
M24CJ
MW24C3J
MR24C3J
9,000
3,070~12,120
N/A
N/A
6
N/A
.89
21.5
13.3
N/A
YES
2.6
124/212/272/335
19 / 24 / 33 / 38
45
14(0)~118
N/A
61
11,200
3,070~13,660
N/A
N/A
8.4
N/A
.83
21.5
12.5
N/A
YES
3.0
124/212/272/335
19 / 24 / 33 / 39
45
14(0)~118
N/A
81
17,000
3,070~20,470
N/A
N/A
7
N/A
.79
18.0
12.0
N/A
YES
5.3
300/399/509/622
29 / 35 / 40 / 45
53
14(0)~118
N/A
127
22,000
3,070~26,270
N/A
N/A
8.7
N/A
.81
20.0
10.8
N/A
No
6.0
300/424/629/742
29 / 35 / 40 / 46
54
14(0)~118
N/A
183
No. x AWG
115/60/1
12
677
20
4 x 18
115/60/1
12
896
20
4 x 18
208/230/60/1
19
1416
25
4 x 18
208/230/60/1
19
2037
25
4 x 18
in
in
ft
oz
ft
ft
R410A
Inverter
Flare
1/4
3/8
41
36
7~66
33
R410A
Inverter
Flare
1/4
3/8
41
36
7~66
33
R410A
Inverter
Flare
1/4
1/2
25
48
10~66
33
R410A
Inverter
Flare
3/8
5/8
25
64
10~98
49
35-1/4x 11-1/4x 8-5/16
35-1/4x 11-1/4x 8-5/16
40-5/8x 12-7/8x 9-5/8
40-5/8x 12-7/8x 9-5/8
23
27
23
27
31
35
32
37
Btu
Btu
Btu
Btu
Pts/h
CFM
dB-A
dB-A
°F
°F
$
V
A
W
A
in
lbs
lbs
in 30-5/16x 21-5/16x 11-5/16 30-5/16x21-5/16x11-5/16 34-5/16x25-7/8x12-5/8 34-5/16 x31-1/2 x12-5/8
lbs
75
75
108
122
lbs
79
79
115
130
lbs
97
97
139
154
lbs
106
106
150
167
Your operating costs will depend on your utility rates and use. The estimated operating cost is based on a electricity cost of $ .115 per kWh.
For more information, visit www.ftc.gov/energy.
Due to continuing research in new energy-saving technology,
specifications are subject to change without notice.
13
Single Zone
25.0 SEER WALL-MOUNTED HEAT PUMP
12000 Btu. Our most efficient unit ever! Features for comfort and convenience year
'round. In heating mode, unit efficiently heats by using approximately 1/4 of the
energy required by electric heat.
Features
• Inverter technology (variable speed compressor)
• High efficiency for low operating cost
• DiamonGold Advanced Corrosion Protection™
• Auto dry indoor coil
• Surge Cool/Heat
• Natural air flow
SU
• Ultra quiet operation
• Sleep mode
PERIOR
25.0 SEER
• Auto restart
• Auto changeover
EF
• BLDC Motor
FICIENC
Y
• Low ambient operation down to 14ºF
(Cooling Mode)
• 24-hour on-off timer
• ENERGY STAR® qualified model
• Hidden display (only visible during operation)
• Multiple ease of installation features (see p.10)
MWH12Y3J
MRH12Y3J
PRECISION
14
SPECIFICATIONS
PERFORMANCE RATINGS
SYSTEM MODEL NO.
INDOOR MODEL
OUTDOOR MODEL
SPECIFICATIONS
CAPACITY COOLING (RATED)
CAPACITY COOLING (MIN~MAX)
CAPACITY HEATING @470F (RATED)
CAPACITY HEATING (MIN~MAX)
COOLING AMPS
HEATING AMPS
SENSIBLE HEAT RATIO
SEER
EER
HSPF
ENERGY STAR
MOISTURE REMOVAL
AIRFLOW (QUIET, LOW, MED, HIGH)
SOUND RATING - INDOOR
SOUND RATING - OUTDOOR
OPERATING RANGE (COOLING)
OPERATING RANGE (HEATING)
EST. YEARLY OPERATING COST
ELECTRICAL DATA
POWER SOURCE
MINIMUM AMPACITY
COOLING WATTS
HEATING WATTS
MAX. TD FUSE/BREAKER
POWER AND COMMUNICATION CABLE
REFRIGERATION SYSTEM
REFRIGERANT
COMPRESSOR TYPE
CONNECTIONS
LIQUID LINE O.D.
SUCTION LINE O.D.
FACTORY PRECHARGE
REFRIGERANT CHARGE
MIN./MAX. LINE LENGTH
MAX. HEIGHT DIFFERENCE
DIMENSIONS & WEIGHT
INDOOR UNIT
WXHXD
NET WEIGHT
SHIPPING WEIGHT
OUTDOOR UNIT
WXHXD
NET WEIGHT
SHIPPING WEIGHT
TOTAL NET WEIGHT
TOTAL SHIPPING WEIGHT
Single Wall Mounted - H/P Inv (High SEER)
12k
HM12YJ
MWH12Y3J
MRH12Y3J
Btu
Btu
Btu
Btu
Pts/h
CFM
dB-A
dB-A
°F
°F
$
V
A
W
W
A
No. x AWG
12,000
3070~14660
13,600
3070~20470
3.8
4.3
.84
25.0
14.0
11.0
Yes (Most Efficient)
1.7
177 / 283 / 417 / 494
17 / 25 / 36 / 42
51
14~118
14~75
77
208/230/60/1
10
857
960
15
4 x 18
in
in
ft
oz
ft
ft
R410A
Twin Rotary
Flare
1/4
3/8
25
44
10~49
23
in
lbs
lbs
34-7/16 x 11-5/8 x 9-1/4
25
29
in
lbs
lbs
lbs
lbs
34-5/16 x 25-7/8 x 12-5/8
95
100
119
128
Your operating costs will depend on your utility rates and use. The estimated operating cost is based on a electricity cost of $ .115 per kWh.
For more information, visit www.ftc.gov/energy.
Due to continuing research in new energy-saving technology,​
specifications are subject to change without notice.
15
Single Zone
WALL-MOUNTED HEAT PUMPS
9000-18000 Btu. Features for comfort and convenience year 'round. In heating
mode, units efficiently heat by using approximately 1/4 of the energy required by
electric heat.
Features
• Inverter technology (variable speed
compressor)
• High efficiency for low operating cost
• DiamonGold Advanced Corrosion Protection™
• Auto dry indoor coil
• Cooling/Heating/Fan mode
• Surge Cool/Heat
• Natural air flow
• 4-Way auto swing
• Ultra quiet operation
• Sleep mode
• Dehumidifying mode
• Auto restart
• Auto changeover
• Built-in low ambient standard, down to 14ºF
(Cooling Mode)
• 24-hour on-off timer
• Condensate sensor connection
• Multiple ease of installation features (see p.10)
MW09Y3J, MW12Y3J
MR09Y3J, MR12Y3J
MW18Y3J
MR18Y3J
PRECISION
16
SPECIFICATIONS
PERFORMANCE RATINGS
SYSTEM MODEL NO.
INDOOR MODEL
OUTDOOR MODEL
SPECIFICATIONS
CAPACITY COOLING (RATED)
Btu
CAPACITY COOLING (MIN~MAX)
Btu
Btu
CAPACITY HEATING @470F (RATED)
CAPACITY HEATING (MIN~MAX)
Btu
COOLING AMPS
HEATING AMPS
SENSIBLE HEAT RATIO
SEER
EER
HSPF
ENERGY STAR
MOISTURE REMOVAL
Pts/h
AIRFLOW (QUIET, LOW, MED, HIGH)
CFM
SOUND RATING - INDOOR
dB-A
SOUND RATING - OUTDOOR
dB-A
OPERATING RANGE (COOLING)(WIND BAFFLE)
°F
OPERATING RANGE (HEATING)
°F
EST. YEARLY OPERATING COST
$
ELECTRICAL DATA
POWER SOURCE
V
MINIMUM AMPACITY
A
COOLING WATTS
W
MAX. TD FUSE/BREAKER
A
No. x AWG
POWER AND COMMUNICATION CABLE
REFRIGERATION SYSTEM
REFRIGERANT
COMPRESSOR TYPE
CONNECTIONS
LIQUID LINE O.D.
in
SUCTION LINE O.D.
in
FACTORY PRECHARGE
ft
REFRIGERANT CHARGE
oz
MIN./MAX. LINE LENGTH
ft
MAX. HEIGHT DIFFERENCE
ft
DIMENSIONS & WEIGHT
INDOOR UNIT
WXHXD
in
NET WEIGHT
lbs
SHIPPING WEIGHT
lbs
OUTDOOR UNIT
WXHXD
in
NET WEIGHT
lbs
SHIPPING WEIGHT
lbs
TOTAL NET WEIGHT
lbs
TOTAL SHIPPING WEIGHT
lbs
Single Wall Mounted - H/P Inv
9k
M09YJ
MW09Y3J
MR09Y3J
12k
M12YJ
MW12Y3J
MR12Y3J
18k
M18YJ
MW18Y3J
MR18Y3J
9,000
3,070~12,620
10,800
3,070~17,060
3
3.7
.88
21.5
13.3
11.0
YES
2.6
124/212/272/335
19 / 24 / 33 / 38
45
14(0)~118
-4~75
61
11,200
3,070~14,660
13,300
3,070~20,470
4.2
4.9
.81
21.5
12.5
11.0
YES
3.0
124/212/272/335
19 / 24 / 33 / 39
45
14(0)~118
-4~75
81
17,000
3,070~20,470
20,200
3,070~30,700
7
7.8
.78
18.0
12.0
9.7
YES
5.3
300/399/509/622
29 / 35 / 40 / 45
53
14(0)~118
-4~75
127
208/230/60/1
10
677
15
4 x 18
208/230/60/1
10
896
15
4 x 18
230/208/60/1
19
1416
20
4 x 18
R410A
Inverter
Flare
1/4
3/8
41
36
7~66
33
R410A
Inverter
Flare
1/4
3/8
41
36
7~66
33
R410A
Inverter
Flare
1/4
1/2
25
48
10~66
33
35-1/4 x11-1/4 x8-1/4
23
27
35-1/4 x11-1/4 x8-1/4
23
27
40-5/8 x 12-7/8 x 9-5/8
31
36
30-5/16x21-5/16x11-5/16
75
79
98
107
30-5/16x21-5/16x11-5/16
75
79
98
107
34-5/16x25-7/8x12-5/8
108
115
139
150
Your operating costs will depend on your utility rates and use. The estimated operating cost is based on a electricity cost of $ .115 per kWh.
For more information, visit www.ftc.gov/energy.
Due to continuing research in new energy-saving technology,
specifications are subject to change without notice.
17
Single Zone
WALL-MOUNTED HEAT PUMPS
24000-36000 Btu. Extensive features for comfort and convenience year 'round. In heating
mode, units efficiently heat by using approximately 1/4 of the energy required by electric
heat.
Features
• Inverter technology (variable speed compressor)
• High efficiency for low operating cost
• DiamonGold Advanced Corrosion Protection™
• Self-cleaning indoor coil
• Cooling/Heating/Fan mode
• Surge Cool/Heat
• Natural air flow
• 4-Way auto swing
• Ultra quiet operation
• Sleep mode
• Dehumidifying mode
• Auto restart
• Auto changeover
• Built-in low ambient standard, down to 14ºF
(Cooling Mode)
• 24-hour on-off timer
• Condensate sensor connection
• Multiple ease of installation features (see p.10)
MW24Y3J, MW30Y3J, MW36Y3J
MR24Y3J, MR30Y3J, MR36Y3J
PRECISION
18
SPECIFICATIONS
PERFORMANCE RATINGS
SYSTEM MODEL NO.
INDOOR MODEL
OUTDOOR MODEL
SPECIFICATIONS
CAPACITY COOLING (RATED)
Btu
CAPACITY COOLING (MIN~MAX)
Btu
Btu
CAPACITY HEATING @170F (RATED)
CAPACITY HEATING (MIN~MAX)
Btu
COOLING AMPS
HEATING AMPS
SENSIBLE HEAT RATIO
SEER
EER
HSPF
ENERGY STAR
MOISTURE REMOVAL
Pts/h
AIRFLOW (QUIET, LOW, MED, HIGH)
CFM
SOUND RATING - INDOOR
dB-A
SOUND RATING - OUTDOOR
dB-A
OPERATING RANGE (COOLING)(WIND BAFFLE)
°F
OPERATING RANGE (HEATING)
°F
EST. YEARLY OPERATING COST
$
No. x AWG
POWER AND COMMUNICATION CABLE
ELECTRICAL DATA
POWER SOURCE
V
MINIMUM AMPACITY
A
COOLING WATTS
W
MAX. TD FUSE/BREAKER
A
REFRIGERATION SYSTEM
REFRIGERANT
COMPRESSOR TYPE
CONNECTIONS
LIQUID LINE O.D.
in
SUCTION LINE O.D.
in
FACTORY PRECHARGE
ft
REFRIGERANT CHARGE
oz
MIN./MAX. LINE LENGTH
ft
MAX. HEIGHT DIFFERENCE
ft
DIMENSIONS & WEIGHT
INDOOR UNIT
WXHXD
in
NET WEIGHT
lbs
SHIPPING WEIGHT
lbs
OUTDOOR UNIT
WXHXD
in
NET WEIGHT
lbs
SHIPPING WEIGHT
lbs
TOTAL NET WEIGHT
lbs
TOTAL SHIPPING WEIGHT
lbs
Single Wall Mounted - H/P Inv
24k
M24YJ
MW24Y3J
MR24Y3J
30k
M30YJ
MW30Y3J
MR30Y3J
36k
M36YJ
MW36Y3J
MR36Y3J
22,000
3,070~30,030
27,600
3,070~38,898
7.9
10.7
30,000
3,070~34,000
32,000
3,070~38,900
13.4
13.9
33,000
3,070~34,000
35,200
3,070~38,900
17.0
16.2
.66
21.0
12.5
11.0
YES
6.8
300/389/512/600
33 / 39 / 43 / 46
54
14(0)~118
-4~75
158
4 x 18
.61
18.5
10.0
10.0
No
10.7
459/530/706/848
33 / 39 / 44 / 49
55
14(0)~118
-4~75
270
4 x 18
.67
16.5
8.2
10.0
No
10.7
459/530/706/848
37 / 40 / 44 / 49
55
14(0)~118
-4~75
395
4 x 18
208/230/60/1
19
1760
25
208/230/60/1
19
3000
25
230/208/60/1
19
4024
25
R410A
Inverter
Flare
3/8
5/8
25
78
10~164
98
R410A
Inverter
Flare
3/8
5/8
25
78
10~164
98
R410A
Inverter
Flare
3/8
5/8
25
78
10~164
98
46-7/8 x 13-5/8 x10-3/8
40
46
46-7/8 x13-5/8 x 10-3/8
40
46
46-7/8 x 13-5/8 x 10-3/8
40
46
34-5/16 x31-1/2 x12-5/8
108
115
148
160
34-5/16 x31-1/2 x12-5/8
108
115
148
160
34-5/16 x31-1/2 x12-5/8
108
115
148
160
Your operating costs will depend on your utility rates and use. The estimated operating cost is based on a electricity cost of $ .115 per kWh.
For more information, visit www.ftc.gov/energy.
Due to continuing research in new energy-saving technology,
specifications are subject to change without notice.
19
Single Zone
CEILING CASSETTE HEAT PUMPS
24000 and 36000 Btu. Ceiling cassette models install nearly flush with a drop ceiling
for a clean and efficient installation.
Features
• Inverter technology (variable speed
compressor)
• 24-hour on-off timer
• Internal condensate pump included
with 31-1/2" lift
• Auto changeover
• Natural air flow
• Auto restart
• Temperature display on remote
Low profile indoor unit is
recessed into the ceiling
for a clean look and greater
clearance.
• Ultra-quiet turbo fan
• 4-Way cooling
• Surge Cool/Heat
• DiamonGold Advanced Corrosion Protection™
• Cooling mode
• Clean, modern look
• Dehumidifying mode
• Flexible installation
• Night Quiet Operation
• ENERGY STAR® qualified models
• Built-in low ambient standard, down
to 14ºF (Cooling mode)
• Precise air distribution
NOTE: Grilles are sold
separately. See optional
accessories on page 11.
• Fan mode
• Independent vane control
• 5 Fan speeds
• Evaporator frost control
MC36Y3J
MC24Y3J
MR24UY3J
MR36UY3J
PRECISION
20
SPECIFICATIONS
PERFORMANCE RATINGS
Single Zone Cassette H/P
SYSTEM MODEL NO.
INDOOR MODEL
OUTDOOR MODEL
SPECIFICATIONS
CAPACITY COOLING (RATED)
Btu
CAPACITY COOLING (MIN~MAX)
Btu
Btu
CAPACITY HEATING @170F (RATED)
CAPACITY HEATING (MIN~MAX)
Btu
COOLING AMPS
HEATING AMPS
SENSIBLE HEAT RATIO
SEER
EER
HSPF
ENERGY STAR *
MOISTURE REMOVAL
Pts/h
AIRFLOW (LOW, MED, HIGH )
CFM
SOUND RATING - INDOOR
dB(A)
SOUND RATING - OUTDOOR
dB(A)
OPERATING RANGE (COOLING)
°F
OPERATING RANGE (HEATING)
°F
EST. YEARLY OPERATING COST
$
ELECTRICAL DATA
POWER SOURCE
V
MINIMUM AMPACITY
A
COOLING WATTS
W
MAX. TD FUSE/BREAKER
A
POWER AND COMMUNICATION CABLE No. x AWG
REFRIGERATION SYSTEM
REFRIGERANT
COMPRESSOR TYPE
CONNECTIONS
LIQUID LINE O.D.
in
SUCTION LINE O.D.
in
FACTORY PRECHARGE
ft
REFRIGERANT CHARGE
oz
MIN./MAX. LINE LENGTH
ft
MAX. HEIGHT DIFFERENCE
ft
DIMENSIONS & WEIGHT
INDOOR UNIT
WXHXD
in
NET WEIGHT
lbs
SHIPPING WEIGHT
lbs
INDOOR UNIT GRILLE** W X H X D
in
INDOOR UNIT GRILLE** NET WEIGHT
lbs
24k
C24YJ
MC24Y3J
MR24UY3J
36k
C36YJ
MC36Y3J
MR36UY3J
24,000
9,700~26,700
27,000
10,900~30,000
15.1
15.1
.77
17.0
12.5
9.7
Yes
5.1
459 / 530 / 600
57
62
5~118
-4~64
172
36,000
14,000~42,000
40,000
14,500~45,000
20.2
20.8
.76
19.0
13.5
9.5
Yes
7.7
918 / 989 / 1,060
65
67
5~118
-4~64
240
208/230/60/1
18.1
1910
30
4 x 18
208/230/60/1
24.5
2970
40
4 x 18
R410A
Twin Rotary
Flare
3/8
5/8
25
71
25~164
98
R410A
Twin Rotary
Flare
3/8
5/8
25
120
25~246
98
33-1/16 x 8-1/16 x 33-1/16
45
58
37-3/8 x 15/16 x 37-3/8
11
33-1/16 x 11-3/8 x 33-1/16
54
65
37-3/8 x 15/16 x 37-3/8
11
37-7/16 x 32-7/8 x 13
132
146
178
203
37-13/32 x 54-3/8 x 13
203
227
257
293
OUTDOOR UNIT
WXHXD
NET WEIGHT
SHIPPING WEIGHT
TOTAL NET WEIGHT
TOTAL SHIPPING WEIGHT
in
lbs
lbs
lbs
lbs
Your operating costs will depend on your utility rates and use. The estimated operating cost is based on a electricity cost of $ .115 per kWh.
For more information, visit www.ftc.gov/energy.
*System meets ENERGY STAR® published minimums.
**Models require grille. Grille sold separately.
Due to continuing research in new energy-saving technology,
specifications are subject to change without notice.
21
Single Zone
CONCEALED DUCT HEAT PUMPS
24000 and 36000 Btu. Indoor unit is installed in the ceiling or furr down for
unobtrusive installation.
Features
• Inverter technology (variable speed
compressor)
• Internal condensate pump included with
31-1/2" lift
• Cooling mode
• Dehumidifying mode
• 3 Fan speeds+
• 24-hour on-off timer
• Auto restart
• Auto changeover
• Sleep mode
• Control lock function
• External Static Pressure Range(ESP)
- 24,000 (0.1 - 0.78) WC
- 36,000 (0.15 - 0.6) WC
MD24Y3J, MD36Y3J
MR24UY3J
MR36UY3J
PRECISION
22
SPECIFICATIONS
PERFORMANCE RATINGS
Single Zone Concealed Ducted H/P
24k
36k
D24YJ
D36YJ
MD24Y3J
MR24UY3J
MD36Y3J
MR36UY3J
24,000
9,700~26,700
27,000
10,900~30,000
15.1
15.1
.68
17.0
12.0
10.0
No
7.0
530 / 618 / 688
56
62
5~118
-4~64
180
36,000
16,000~41,400
40,000
17,500~48,000
20.8
21.4
.67
17.6
12.1
9.2
No
10.6
706 / 953 / 1,130
56
67
5~118
-4~64
268
208/230/60/1
18.1
2000
30
4 x 18
208/230/60/1
24.5
2910
40
4 x 18
R410A
Twin Rotary
Flare
3/8
5/8
25
71
25~164
98
R410A
Twin Rotary
Flare
3/8
5/8
25
120
25~246
98
46-9/16 x 11-3/4 x 17-3/4
73
95
48-1/2 x 15 x 23-1/4
125
139
37-7/16 x 32-7/8 x 13
132
146
205
240
37-7/16 x 54-3/8 x 13
203
227
327
366
SYSTEM MODEL NO.
INDOOR MODEL
OUTDOOR MODEL
SPECIFICATIONS
CAPACITY COOLING (RATED)
Btu
CAPACITY COOLING (MIN~MAX)
Btu
Btu
CAPACITY HEATING @470F (RATED)
CAPACITY HEATING (MIN~MAX)
Btu
COOLING AMPS
HEATING AMPS
SENSIBLE HEAT RATIO
SEER
EER
HSPF
ENERGY STAR
MOISTURE REMOVAL
Pts/h
AIRFLOW (LOW, MED, HIGH )
CFM
SOUND RATING - INDOOR
dB(A)
SOUND RATING - OUTDOOR
dB(A)
OPERATING RANGE (COOLING)
°F
OPERATING RANGE (HEATING)
°F
EST. YEARLY OPERATING COST
$
ELECTRICAL DATA
POWER SOURCE
MINIMUM AMPACITY
A
COOLING WATTS
W
MAX. TD FUSE/BREAKER
A
POWER AND COMMUNICATION CABLE No. x AWG
REFRIGERATION SYSTEM
REFRIGERANT
COMPRESSOR TYPE
CONNECTIONS
LIQUID LINE O.D.
in
SUCTION LINE O.D.
in
FACTORY PRECHARGE
ft
REFRIGERANT CHARGE
oz
MIN./MAX. LINE LENGTH
ft
MAX. HEIGHT DIFFERENCE
ft
DIMENSIONS & WEIGHT
INDOOR UNIT
WXHXD
in
NET WEIGHT
lbs
SHIPPING WEIGHT
lbs
OUTDOOR UNIT
WXHXD
in
NET WEIGHT
lbs
SHIPPING WEIGHT
lbs
TOTAL NET WEIGHT
lbs
TOTAL SHIPPING WEIGHT
lbs
Your operating costs will depend on your utility rates and use. The estimated operating cost is based on a electricity cost of $ .115 per kWh.
For more information, visit www.ftc.gov/energy.
Due to continuing research in new energy-saving technology,
specifications are subject to change without notice.
23
Multizone
WALL-MOUNTED HEAT PUMPS
High efficiency heat pumps with features for comfort and convenience year
'round. In heating mode, units efficiently heat by using approximately 1/4 of the
energy required by electric heat.
Features
• Inverter technology (variable speed
compressor)
• High efficiency for low operating cost
• Auto restart
• Built-in low ambient standard, down to
14ºF (Cooling Mode)
• DiamonGold Advanced Corrosion
Protection™
• 24-hour on-off timer
• Self-cleaning indoor coil
• Built-in kick stand
• Condensate sensor connection
• Cooling/Heating/Fan mode
• Surge Cool/Heat
• Natural air flow
• 4-Way auto swing
• Ultra quiet operation
• Sleep mode
• Dehumidifying mode
MW09Y3J, MW12Y3J
MW18Y3J
MR24DY3JM
MR36TQY3JM
PRECISION
24
SPECIFICATIONS
PERFORMANCE RATINGS
INDOOR MODEL
SPECIFICATIONS
CAPACITY COOLING (RATED)
CAPACITY HEATING (RATED)
MOISTURE REMOVAL
AIRFLOW (QUIET, LOW, MED, HIGH)
SOUND RATING - INDOOR
ELECTRICAL DATA
POWER SOURCE
REFRIGERATION SYSTEM
CONNECTIONS
LIQUID LINE O.D.
SUCTION LINE O.D.
DIMENSIONS & WEIGHT
WXHXD
NET WEIGHT
SHIPPING WEIGHT
Multi Zone Wall Mounted
Btu
Btu
Pts/h
CFM
dB-A
V, Ø, Hz
in
in
in
lbs
lbs
9k
MW09Y3J
12k
MW12Y3J
18k
MW18Y3J
9,000
10,800
2.6
124/212/272/335
19 / 24 / 33 / 38
11,200
13,300
3.0
124/212/272/335
19 / 24 / 33 / 39
17,000
20,200
5.3
300/399/509/622
29 / 35 / 40 / 45
230/208-60-1
230/208-60-1
230/208-60-1
Flare
1/4
3/8
Flare
1/4
3/8
Flare
1/4
1/2
35-1/4 x11-1/4 x 8-1/4 35-1/4 x 11-1/4 x 8-1/4 40-5/8 x 12-7/8 x 9-5/8
23
23
31
27
27
35
PERFORMANCE RATINGS
OUTDOOR MODEL
SPECIFICATIONS
POWER SOURCE
EST. YEARLY OPERATING COST
RUNNING CURRENT COOLING MIN.~RATED~MAX.
RUNNING CURRENT HEATING MIN.~RATED~MAX.
POWER INPUT COOLING MIN.~RATED~MAX.
POWER INPUT HEATING MIN.~RATED~MAX.
POWER AND COMMUNICATION CABLE
DIMENSIONS W X H X D
NET WEIGHT
SHIPPING WEIGHT
REFRIGERATION SYSTEM
REFRIGERANT
FACTORY PRECHARGE
REFRIGERANT CHARGE
LIQUID LINE O.D.
SUCTION LINE O.D.
MIN./MAX. LINE LENGTH (EACH)
MIN./MAX. LINE LENGTH (TOTAL)
MAX. HEIGHT DIFFERENCE
SOUND PRESSURE LEVEL COOLING
SOUND PRESSURE LEVEL HEATING
OPERATING RANGE COOLING MIN. ~ MAX.
OPERATINGRANGE HEATING MIN. ~ MAX.
MINIMUM AMPACITY
MAX. TD FUSE/BREAKER
Multi Outdoor
$
A
A
W
W
No. x AWG
inch
lbs
lbs
ft
oz
in
in
ft
ft
ft
A
A
°F DB
°F WB
A
A
24k
MR24DY3JM
36k
MR36TQY3JM
208/230/60/1
122-125
2.8~6.6~14.0
3.0~10.2~14.1
390~1430~3090
420~2210~3100
4 X 18
34-1/4 x 31-7/8 x12-5/8
130
139
208/230/60/1
170-245
3.3~11.8~17.0
4.9~15.5~17.8
770~2720~3920
1120~3580~4100
4 X 18
35-7/16 x 45-7/8 x14-5/8
209
223
R410A
74
74
1/4
3/8
10~82
75~246
49
51
51
14 ~ 114
5 ~ 64
15
25
R410A
98
124
1/4
3/8
10~82
75~246
49
57
57
14 ~ 114
5 ~ 64
17
25
Your operating costs will depend on your utility rates and use. The estimated operating cost is based on a electricity cost of $ .115 per kWh.
For more information, visit www.ftc.gov/energy.
Due to continuing research in new energy-saving technology,
specifications are subject to change without notice.
25
Multizone
CEILING CASSETTE HEAT PUMPS
Ceiling cassette models install nearly flush with a drop ceiling for a clean and
efficient installation.
Features
• Inverter technology (variable speed
compressor)
• 24-hour on-off timer
• Internal condensate pump included
with 31-1/2" lift
• Temperature display on remote
• Natural air flow
• Auto restart
• Ultra-quiet turbo fan
• 4-Way cooling
• DiamonGold Advanced Corrosion
Protection™
• Surge Cool/Heat
• Clean, modern look
• Cooling mode
• Flexible installation
• Dehumidifying mode
• ENERGY STAR® qualified models
• Night Quiet Operation
• Precise air distribution
NOTE: Grilles are sold
separately. See optional
accessories on page 11.
• Built-in low ambient standard, down
to 14ºF (Cooling mode)
• Fan mode
• Independent vane control
• 5 Fan speeds
• Evaporator frost control
MC12Y3JM, MC18Y3JM
MR24DY3JM
MR36TQY3JM
PRECISION
26
SPECIFICATIONS
PERFORMANCE RATINGS
INDOOR MODEL
SPECIFICATIONS
CAPACITY COOLING (RATED)
CAPACITY HEATING (RATED)
MOISTURE REMOVAL
AIRFLOW ( LOW, MED, HIGH)
SOUND RATING - INDOOR
ELECTRICAL DATA
POWER SOURCE
POWER AND COMMUNICATION CABLE
REFRIGERATION SYSTEM
CONNECTIONS
LIQUID LINE O.D.
SUCTION LINE O.D.
DIMENSIONS & WEIGHT
WXHXD
NET WEIGHT
SHIPPING WEIGHT
NDOOR UNIT GRILLE* W X H X D
INDOOR UNIT GRILLE* NET WEIGHT
Multi Zone Cassette
MC12Y3JM
MC18Y3JM
Btu
Btu
Pts/h
CFM
dB-A
12,000
13,800
4.2
247 / 283 /335
32/35/38
18,000
19,000
4.2
388 / 424 / 459
34/37/38
V, Ø, Hz
No. x AWG
208/230, 1, 60
4C x 18
208/230, 1, 60
4C x 18
in
in
Flare
1/4
3/8
Flare
1/4
1/2
in
lbs
lbs
in
lbs
22-7/16 x 8-7/16 x 22-7/16
31
36
27-9/16 x 7/8 x 27-9/16
7
22-7/16 x 10-3/32 x 22-7/16
33
42
27-9/16 x 7/8 x 27-9/16
7
PERFORMANCE RATINGS
OUTDOOR MODEL
SPECIFICATIONS
POWER SOURCE
EST. YEARLY OPERATING COST
RUNNING CURRENT COOLING MIN.~RATED~MAX.
RUNNING CURRENT HEATING MIN.~RATED~MAX.
POWER INPUT COOLING MIN.~RATED~MAX.
POWER INPUT HEATING MIN.~RATED~MAX.
POWER AND COMMUNICATION CABLE
DIMENSIONS W X H X D
NET WEIGHT
SHIPPING WEIGHT
REFRIGERATION SYSTEM
REFRIGERANT
FACTORY PRECHARGE
REFRIGERANT CHARGE
LIQUID LINE O.D.
SUCTION LINE O.D.
MIN./MAX. LINE LENGTH (EACH)
MIN./MAX. LINE LENGTH (TOTAL)
MAX. HEIGHT DIFFERENCE
SOUND PRESSURE LEVEL COOLING
SOUND PRESSURE LEVEL HEATING
OPERATING RANGE COOLING MIN. ~ MAX.
OPERATINGRANGE HEATING MIN. ~ MAX.
MINIMUM AMPACITY
MAX. TD FUSE/BREAKER
Multi Outdoor
$
A
A
W
W
No. x AWG
inch
lbs
lbs
ft
oz
in
in
ft
ft
ft
A
A
°F DB
°F WB
A
A
24k
MR24DY3JM
36k
MR36TQY3JM
208/230/60/1
122-125
2.8~6.6~14.0
3.0~10.2~14.1
390~1430~3090
420~2210~3100
4 X 18
34-1/4 x 31-7/8 x12-5/8
130
139
208/230/60/1
170-245
3.3~11.8~17.0
4.9~15.5~17.8
770~2720~3920
1120~3580~4100
4 X 18
35-7/16 x 45-7/8 x14-5/8
209
223
R410A
74
74
1/4
3/8
10~82
75~246
49
51
51
14 ~ 114
5 ~ 64
15
25
R410A
98
124
1/4
3/8
10~82
75~246
49
57
57
14 ~ 114
5 ~ 64
17
25
*Models require grille. Grille sold separately.
Your operating costs will depend on your utility rates and use. The estimated operating cost is based on a electricity cost of $ .115 per kWh.
For more information, visit www.ftc.gov/energy.
Due to continuing research in new energy-saving technology, specifications are subject to change without notice.
27
Multizone
CONCEALED DUCT HEAT PUMPS
Indoor unit is installed in the ceiling or furr down for unobtrusive installation.
Features
• Inverter technology (variable speed
compressor)
• Internal condensate pump included with
31-1/2" lift
• Cooling mode
Fresh air can be easily
introduced to the
conditioned space whenever
required.
• Dehumidifying mode
• 3 Fan speeds+
• 24-hour on-off timer
• Auto restart
• Sleep mode
• Control lock function
• External Static Pressure Range(ESP)
- 12,000 ( 0.0 - 0.16) WC
- 18,000 ( 0.0 - 0.16) WC
MD12Y3JM, MD18Y3JM
MR24DY3JM
MR36TQY3JM
PRECISION
28
SPECIFICATIONS
PERFORMANCE RATINGS
INDOOR MODEL
SPECIFICATIONS
CAPACITY COOLING (RATED)
CAPACITY HEATING (RATED)
MOISTURE REMOVAL
AIRFLOW ( LOW, MED, HIGH)
SOUND RATING - INDOOR
ELECTRICAL DATA
POWER SOURCE
POWER AND COMMUNICATION CABLE
REFRIGERATION SYSTEM
CONNECTIONS
LIQUID LINE O.D.
SUCTION LINE O.D.
DIMENSIONS & WEIGHT
WXHXD
NET WEIGHT
SHIPPING WEIGHT
Multi Zone Concealed Ducted
MD12Y3JM
MD18Y3JM
Btu
Btu
Pts/h
CFM
dB-A
12,000
13,800
2.5
265 / 300 / 335
26/31/33
18,000
19,000
4.2
406 / 477 / 530
29/31/34
No. x AWG
208/230, 1, 60
4C x 18
208/230, 1, 60
4C x 18
in
in
Flare
1/4
3/8
Flare
1/4
1/2
in
lbs
lbs
32-9/32 x 7-15/32 x 22-5/8
45
51
43-5/16 x 7-15/32 x 22-5/8
58
65
PERFORMANCE RATINGS
OUTDOOR MODEL
SPECIFICATIONS
POWER SOURCE
EST. YEARLY OPERATING COST
$
RUNNING CURRENT COOLING MIN.~RATED~MAX.
A
RUNNING CURRENT HEATING MIN.~RATED~MAX.
A
POWER INPUT COOLING MIN.~RATED~MAX.
W
POWER INPUT HEATING MIN.~RATED~MAX.
W
POWER AND COMMUNICATION CABLE
No. x AWG
DIMENSIONS W X H X D
inch
NET WEIGHT
lbs
SHIPPING WEIGHT
lbs
REFRIGERATION SYSTEM
REFRIGERANT
FACTORY PRECHARGE
ft
REFRIGERANT CHARGE
oz
LIQUID LINE O.D.
in
SUCTION LINE O.D.
in
MAX. LINE LENGTH
ft
MAX. HEIGHT DIFFERENCE
ft
SOUND PRESSURE LEVEL COOLING
A
SOUND PRESSURE LEVEL HEATING
A
OPERATING RANGE COOLING MIN. ~ MAX.
°F DB
OPERATINGRANGE HEATING MIN. ~ MAX.
°F WB
MINIMUM AMPACITY
A
MAX. TD FUSE/BREAKER
A
Multi Outdoor
24k
MR24DY3JM
36k
MR36TQY3JM
208/230/60/1
122-125
2.8~6.6~14.0
3.0~10.2~14.1
390~1430~3090
420~2210~3100
4 X 18
34-1/4 x 31-7/8 x 12-5/8
130
139
208/230/60/1
170-245
3.3~11.8~17.0
4.9~15.5~17.8
770~2720~3920
1120~3580~4100
4 X 18
35-7/16 x 45-7/8 x 14-5/8
209
223
R410A
74
74
1/4
3/8
246
49
51
51
14 ~ 114
5 ~ 64
15.4
25
R410A
98
124
1/4
3/8
246
49
57
57
14 ~ 114
5 ~ 64
16.8
25
Your operating costs will depend on your utility rates and use. The estimated operating cost is based on a electricity cost of $ .115 per kWh.
For more information, visit www.ftc.gov/energy.
Due to continuing research in new energy-saving technology, specifications are subject to change without notice.
29
Remote Controls
Wired and wireless controllers.
Wireless Controller
Wired Controllers
Wall control thermostat with infrared sensor
that enables communication between the remote
control and the thermostat.
Cassette & All
Wall-mounted
Models
Concealed Ducted
D24YJ, D36YJ
MD12Y3JM, MD18Y3JM
DWC1- Optional
All Ductless Models
PROGRAMMABLE SETTINGS
30
•
Simple program ( 1 to 7 hour) ON/OFF
•
Sleep program ON/OFF at set time
•
ON at set time
•
OFF at set time
•
7 Day schedule
•
Vacation at user set time ON/OFF
Multizone
Mix and match wall-mounted,
concealed duct and ceiling
cassette models.
131
MULTIZONE
COMBINATIONS
Enjoy the flexibility
to mix and match
systems to fit your
application.
PRECISION
31
SPECIFICATIONS
24K
2
Indoor Units
Combination of Indoor Units (kBTU/h Class)
Wall Mounted
9K
12K
18K







Ducted
12K
18K
Cassette
12K
18K























3
Indoor Units













2
Indoor Units
17000
19800
19.0
12.6
7.7
3.0
—
11100
17000
23100
19.0
12.8
7.7
3.1
—
11400
19200
27500
19.0
13.1
8.2
3.3
YES
10798
18600
23100
16.7
12.1
7.8
3.1
—
10798
18600
27500
16.7
12.3
8.2
3.3
YES
10798
18600
23100
19.0
12.8
7.7
3.1
—
10798
18600
27500
19.0
13.1
8.2
3.3
YES
11400
19200
25500
19.0
13.1
8.2
3.3
YES
11400
19200
27500
19.0
13.1
8.2
3.3
YES
11400
18600
25500
16.7
12.3
8.2
3.3
YES
11400
18600
27500
16.7
12.3
8.2
3.3
YES
11400
18600
25500
19.0
13.1
8.2
3.3
YES
11400
18600
27500
19.0
13.1
8.2
3.3
YES
11400
18600
25500
16.7
12.3
8.2
3.3
YES
11400
18600
27500
19.0
13.1
8.2
3.3
YES
12300
18600
25500
14.4
11.5
8.1
3.3
—
12300
18600
25500
19.0
13.1
8.2
3.3
YES
11700
19200
28800
21.7
13.4
9.4
3.5
YES
11700
19200
28800
21.7
13.4
9.4
3.5
YES
11700
18600
28800
19.5
12.6
9.0
3.5
YES
11700
18600
28800
21.7
13.4
9.4
3.5
YES
11700
19200
28800
21.7
13.4
9.4
3.5
YES
11700
18600
28800
19.0
12.6
9.0
3.5
YES
18600
28800
21.7
13.4
9.4
3.5
YES
11700
18600
28800
19.0
12.6
9.0
3.5
YES

11700
18600
28800
21.7
13.4
9.4
3.5
YES
Combination of Indoor Units (kBTU/h Class)
Wall Mounted
9K
12K
18K
Ducted
12K
18K
Cassette
12K
18K





























*Systems meet ENERGY STAR® published minimums.
32
SEER
10798
11700

36K
Max
Efficiency
EER HSPF COP E-STAR*




Min
Capacity
Nominal
Efficiency
HSPF COP E-STAR*
Min
Capacity
Nominal
Max
SEER
EER
10798
18000
19800
13.5
9.5
12597
21000
23100
14.1
16197
27000
29700
15.8
10798
34000
36300
13.8
10798
34000
36300
15.4
10798
34000
36300
14.1
10.0
10798
34000
36300
15.8
11.2
10.0
3.1
—
14397
24000
26400
14.7
10.3
10.0
3.1
—
17996
30000
33000
16.4
11.5
10.0
3.1
—
17996
34000
36300
14.3
10.1
9.5
3.1
—
17996
34000
36300
16.0
11.3
9.5
3.1
—
17996
34000
36300
14.7
10.3
10,0
3.1
—
17996
34000
36300
16.4
11.5
10,0
3.1
—
19796
33000
36300
17.1
11.5
10.1
3.2
—
19796
34000
36300
16.0
11.3
9.5
3.1
—
19796
34000
36300
15.8
11.2
9.6
3.1
—
9.3
2.9
—
10.0
8.9
2.8
—
11.2
10.0
3.1
—
9.7
8.9
2.8
—
10.9
9.5
3.1
—
8.9
2.8
—
SPECIFICATIONS
36K
Combination of Indoor Units (kBTU/h Class)
Wall Mounted
9K
12K
18K
Ducted
12K
18K


Cassette
12K
18K
















3
Indoor Units


















































































Min
Capacity
Nominal
Max
SEER
Efficiency
EER HSPF COP E-STAR*
19796
34000
36300
16.4
11.5
10.0
3.1
—
19796
34000
36300
17.1
11.5
10.1
3.2
—
14397
24000
26400
13.9
9.9
9.0
3.0
—
17996
30000
33000
15.5
11.1
9.0
3.0
—
14397
24000
26400
14.3
10.1
9.5
3.1
—
17996
30000
33000
16.0
11.3
9.5
3.1
—
19796
33000
36300
15.4
11.0
9.0
3.0
—
19796
33000
36300
16.0
11.3
9.5
3.1
—
19796
33000
36300
15.8
11.2
9.6
3.1
—
14397
24000
26400
14.7
10.3
10.0
3.1
—
17996
17996
17996
16.4
11.5
10.0
3.1
—
19796
33000
36300
17.1
11.5
10.1
3.2
—
—
16197
27000
29700
15.8
11.2
10.0
3.1
17996
30000
33000
16.4
11.5
10.0
3.1
—
20396
34000
37400
17.5
12.5
10.5
3.4
YES
10798
34000
37400
16.0
11.3
9.5
3.1
—
10798
34000
37400
17.0
12.3
10.0
3.3
YES
10798
34000
37400
16.4
11.5
10.0
3.1
—
10798
34000
37400
17.5
12.5
10.5
3.4
YES
20396
34000
37400
17.1
12.0
10.4
3.3
YES
YES
20396
34000
37400
17.5
12.5
10.4
3.4
10798
34000
37400
16.7
11.8
9.8
3.2
—
10798
34000
37400
17.0
12.3
10.0
3.3
YES
10798
34000
37400
17.1
12.0
10.4
3.3
YES
10798
34000
37400
17.5
12.5
10.5
3.4
YES
20396
34000
37400
17.5
12.5
10.5
3.4
YES
10798
34000
37400
17.0
12.3
10.0
3.3
YES
10798
34000
37400
17.0
12.3
10.0
3.3
YES
10798
34000
37400
17.5
12.5
10.5
3.4
YES
10798
34000
37400
17.5
12.5
10.5
3.4
YES
10798
34000
37400
16.7
11.8
9.8
3.3
—
10798
34000
37400
17.0
12.3
10.0
3.3
YES
10798
34000
37400
17.0
12.3
10.0
3.3
YES
10798
34000
37400
17.0
12.3
10.0
3.3
YES
10798
34000
37400
17.1
12.0
10.4
3.3
YES
10798
34000
37400
17.5
12.5
10.5
3.4
YES
10798
34000
37400
17.5
12.5
10.5
3.4
YES
20396
34000
37400
17.5
12.5
10.5
3.4
YES
20396
34000
37400
17.5
12.5
10.5
3.4
YES
20396
34000
37400
17.0
12.3
10.0
3.3
YES
20396
34000
37400
17.0
12.3
10.0
3.3
YES
20396
34000
37400
17.5
12.5
10.5
3.4
YES
20396
34000
37400
17.5
12.5
10.5
3.4
YES
20396
34000
37400
17.5
12.5
10.5
3.4
YES
20396
34000
37400
17.0
12.3
10.0
3.3
YES
20396
34000
37400
17.0
12.3
10.0
3.3
YES
*Systems meet ENERGY STAR® published minimums.
33
SPECIFICATIONS
36K
3
Combination of Indoor Units (kBTU/h Class)
Wall Mounted
9K
12K
18K






Indoor Units
Ducted
12K
18K



























Indoor Units








































SEER
20396
34000
37400
17.5
12.5
10.5
3.4
YES
20396
34000
37400
17.5
12.5
10.5
3.4
YES
20396
34000
37400
17.0
12.3
10.0
3.3
YES
20396
34000
37400
17.0
12.3
10.0
3.3
YES
20396
34000
37400
17.5
12.5
10.5
3.4
YES
20396
34000
37400
17.5
12.5
10.5
3.4
YES
20396
34000
37400
17.0
12.3
10.0
3.3
YES
20396
34000
37400
17.5
12.5
10.5
3.4
YES
20396
34000
37400
17.0
12.3
10.0
3.3
YES
20396
34000
37400
17.0
12.3
10.0
3.3
YES
20396
34000
37400
17.0
12.3
10.0
3.3
YES
20396
34000
37400
16.5
12.0
9.5
3.2
YES
20396
34000
37400
16.5
12.0
9.5
3.2
YES
20396
34000
37400
17.0
12.3
10..0
3.3
YES
20396
34000
37400
17.0
12.3
10.0
3.3
YES
20396
34000
37400
16.5
12.0
9.5
3.2
YES
20396
34000
37400
17.0
12.3
10.0
3.3
YES
20396
34000
37400
17.0
12.3
10.0
3.3
YES
20396
34000
37400
17.0
12.3
10.0
3.3
YES
20396
34000
37400
17.5
12.5
10.4
3.4
YES
20396
34000
37400
17.5
12.5
10.4
3.4
YES
20396
34000
37400
17.5
12.5
10.4
3.4
YES
20396
34000
37400
17.5
12.5
10.4
3.4
YES
20396
34000
37400
17.5
12.5
10.4
3.4
YES
20396
34000
37400
17.5
12.5
10.4
3.4
YES
10798
34000
37400
17.0
12.3
10.0
3.3
YES
10798
34000
37400
17.0
12.3
10.0
3.3
YES
10798
34000
37400
17.5
12.5
10.4
3.4
YES
10798
34000
37400
17.5
12.5
10.4
3.4
YES
20396
34000
37400
17.5
12.5
10.4
3.4
YES
10798
34000
37400
17.0
12.3
10.0
3.3
YES
10798
34000
37400
17.5
12.5
10.4
3.4
YES
10798
34000
37400
17.0
12.3
10.0
3.3
YES
10798
34000
37400
17.5
12.5
10.4
3.4
YES
20396
34000
37400
17.5
12.5
10.4
3.4
YES
10798
34000
37400
17.0
12.3
10.0
3.3
YES
34000
37400
17.5
12.5
10.4
3.4
YES
34000
37400
16.5
12.0
9.5
3.2
YES
20396
34000
37400
17.0
12.3
10.0
3.3
YES
20396
34000
37400
17.5
12.5
10.4
3.4
YES
20396
34000
37400
17.0
12.3
10.0
3.3
YES

20396
34000
37400
17.0
12.3
10.0
3.3
YES

20396
34000
37400
17.5
12.5
10.4
3.4
YES


*Systems meet ENERGY STAR® published minimums.
Max
Efficiency
EER HSPF COP E-STAR*
10798


Min
Capacity
Nominal
20396


34









4
Cassette
12K 18K
NOMENCLATURE
1
Series
Mini-split
1
2
M
2
3
RH
3
Model Type
W= Wall mounted
C= Cassette
D= Concealed Ducted
R= Outdoor component
WH= Wall mounted High SEER
RH= Outdoor high SEER
4
36
Capacity
9 = 9,000 BTU/h
12 = 12,000 BTU/h
18 = 18,000 BTU/h
24 = 24,000 BTU/h
30 = 30,000 BTU/h
36 = 36,000 BTU/h
4
D
Application
5
Y
5 Refrigeration 6
Cycle
6
7
3
Voltage
1 = 115V/60hz/1
Empty = Single C = Cool Only
D = Dual Zone Y = Heat Pump 3 = 230V/60hz/1
T = Tri‐Zone
Q = Quad Zone
U = Universal
7
8
J
Marketing Model
(Internal Use)
8
M
Installation Type
M = Multi Zone
Refrigeration Line Sets-Minimum/Maximum Lengths
Single Zone
System Model
Outdoor
Indoor
Min./Max. in Feet
M09YJ
MR09Y3J
MW09Y3J
7 / 66
M12YJ
MR12Y3J
MW12Y3J
7 / 66
M18YJ
MR18Y3J
MW18Y3J
10 / 66
M09CJ
MR09C1J
MW09C1J
7 / 66
M12CJ
MR12C1J
MW12C1J
7 / 66
M18CJ
MR18C3J
MW18C3J
10 / 66
M24CJ
MR24C3J
MW24C3J
10/ 98
M24YJ
MR24Y3J
MW24Y3J
10 / 164
M30YJ
MR30Y3J
MW30Y3J
10 / 164
M36YJ
MR36Y3J
MW36Y3J
10 / 164
HM12YJ
MHR12Y3J
MHW12Y3J
10 / 49
C24YJ
MR24UY3J
MC24Y3J
25 / 164
C36YJ
MR36UY3J
MC36Y3J
25 / 246
D24YJ
MR24UY3J
MD24Y3J
25 / 164
D36YJ
MR36UY3J
MD36Y3J
25 / 246
Multizone Outdoor
MR24DY3JM
MR36TQY3JM
75 / 246
75 / 246
Min./Max. Total
25 / 82
25 / 82
Min./Max. Each
10 Ft
10 Ft
Minimum Each
35
Friedrich Air Conditioning Co. l 10001 Reunion Place, Suite 500 l San Antonio, TX 78216 l 877.599.5665
www.friedrich.com
Commercial_Ductless_Brochure_2014 (4-14)
Printed in USA
Download PDF

advertising