Fujitsu | 9RLS3Y | Halcyon Brochure | Fujitsu 9RLS3Y Halcyon Brochure

MINI-SPLIT HEATING AND COOLING SYSTEMS
FOR RESIDENTIAL AND LIGHT COMMERCIAL APPLICATIONS
1
3
TABLE OF CONTENTS
FEATURES
QUIETLY REVOLUTIONIZING
ENERGY-EFFICIENT HOME COMFORT.
Mini-Splits Defined ......................................... 4
Individual Zoning ........................................... 6
Comfort Solution ............................................ 8
Energy Efficient .............................................. 9
Comfort & Convenience ................................ 10
Applications ................................................. 11
FGLair¬ App .................................................. 12
WiFi Selection Guide ..................................... 13
XLTH Story .................................................... 14
Feature Explanation ..................................... 15
System Feature Summary Table ................... 16
MODEL LINEUP
Indoor and Outdoor Model Table .................. 18
SINGLE-ZONE MINI-SPLITS
Wall Mount................................................... 20
Floor Mount .................................................. 32
Compact Cassette ......................................... 34
Slim Duct ...................................................... 36
Universal Floor/Ceiling.................................. 38
Ceiling Suspended ........................................ 38
Large Cassette .............................................. 40
MULTI-ZONE MINI-SPLITS
Overview ...................................................... 42
Indoor Units
Wall Mount ................................................. 46
Slim Duct .................................................... 48
Compact Cassette ....................................... 50
Floor Mount ................................................ 52
Outdoor Units
Multi-Zone (2-4 Zones) .............................. 54
XLTH Multi-Zone (2-3 Zones) ...................... 56
Flex-Zone (2-8 Zones) ................................ 58
Branch Boxes .......................................... 60
Piping...................................................... 61
Allowable Combinations............................... 64
ACCESSORIES
Descriptions ................................................. 67
Compatibility Chart....................................... 69
MISCELLANEOUS
Line Set Length Chart ................................... 70
Model Nomenclature .................................... 70
2
3
FEATURES
HEAT PUMPS PROVIDE HEAT
WHEN IT IS COLD
Available in numerous mix-and-match capacities and
configurations, there’s a Halcyon mini-split system for even
the most difficult to heat and cool areas.
AIR CONDITIONERS PROVIDE COOLING
WHEN IT’S WARM
Come spring and summer, simply reverse the process and
put the same system into “cooling mode” and transfer heat
from indoors to the outside. For many climates, the advanced
technology that goes into these units creates a far more
cost effective alternative to either gas or oil-fired units for
heat, or a central ducted system for air conditioning. Fujitsu’s
full mini-split line up are heat pumps, which provide both
heating and cooling.
HOW DOES A MINI-SPLIT WORK?
Like your refrigerator, heat pumps use electricity to pump
refrigerant and transfer heat from one space to another.
When we transfer heat from within our home to the
outdoors, we call it “air conditioning”. Conversely, when we
transfer heat from the outdoors to within the home, we call
it a “heat-pump”.
evaporator
Halcyon systems eliminate the need for a basement or atticlocated evaporator unit and bulky ductwork by using thin
copper tubing that pumps refrigerant directly to discreet wall
mounted or concealed units inside. Even more remarkable,
this same unit works in reverse in winter, absorbing heat
from the outside air and moving it indoors to heat your
home. The result? Efficient cooling and heating for yearround, whole-house comfort in most climates.
condenser
WHAT IS A MINI-SPLIT?
Heat In
Heat
Out
compressor
expansion
valve
BASIC AIR CONDITIONER CONFIGURATION
Heat Out
condenser
Because refrigerant is naturally much colder than outdoor
temperatures even on a very cold day, it actually absorbs
heat from outdoors, and transfers the heat it absorbs outside
to within your home. The refrigerant’s physical properties
do this naturally. We use efficient compressors to pump
refrigerant via small copper tubing from outdoors to indoors.
Because we move the heat rather than create it (as electric
baseboard or resistant heat does), we can deliver up to 4
times the heat for the energy we consume as baseboard
heat!
BASIC HEAT PUMP CONFIGURATION
evaporator
FUJITSU MINI-SPLITS:
YEAR-ROUND, WHOLE-HOME OR BUSINESS
ENERGY EFFICIENT HEATING AND COOLING
Heat
In
compressor
expansion
valve
SLIM DUCT UNIT
ELECTRIC HEATERS VERSUS HEAT PUMPS
WALL MOUNT UNIT
Indoor unit
Refrigerant lines,
electric, drain
Outdoor
unit
Unit Can Be
Showcased...
Wall mounted units
eliminate the need for
ductwork, mount high on
a wall and deliver all of
the cooling and heating
needed.
Air
supply
grille
...or Hidden
Slim Duct units are
mounted above a ceiling
or in a framed enclosure
below a ceiling, so only
the grilles show for a
clean look. They require
minimal ductwork.
Air
return
grille
An electric heater converts electricity directly to heat,
and if we assume that the heat loss is zero, the output
from one kilowatt input is one kilowatt or 3,400 BTU
and the EER is 3.4.
Heat pumps are more efficient than some other forms
of heating because heat pumps do not actually create
heat - they just move it from one place to another. For
example, the output of an efficient 10 EER heat pump
is almost triple that of an electric heater.
*EER (Energy Efficiency Rating) = Rated BTU capacity divided by total kW input.
4
5
FEATURES
INDIVIDUAL ZONING:
PERSONALIZED WHOLE-HOME COMFORT
SLIM DUCT
Halcyon HFI Systems are some of today’s most advanced forms of heating and air conditioning. One
outdoor unit can operate up to 8 indoor units simultaneously. Fujitsu’s HFI Systems are super quiet as
well as highly energy efficient.
•
– This
Mounted in a ceiling or in a framed enclosure
below a ceiling. They use minimal ductwork and
remain very energy efficient.
symbol denotes indoor units that can be used in single OR multi-zone applications
• Each indoor unit can be operated independently via remote control
• Concealed and out of sight
• Choose from a variety of indoor unit styles
• Look of central air with the efficiency of a
mini-split
• Provide both heating and cooling (not simultaneously)
• Less ducts = higher efficiency
18, 24, 36,000 BTUh
• High energy efficiencies
• Quiet operation
WALL MOUNTED
They mount high on a wall, out of sight and do not
require ductwork, increasing energy efficiency.
• Quiet operation
• Easy maintenance
• H
igh delivered efficiency means lower utility bills
FLOOR MOUNTED
Floor mount systems are ideal for residential
radiator replacements or any room with limited
upper wall space,like a kitchen or sunroom.
• Compact size fits easily under a standard
window
• Features twin airflow for improved heat
delivery and help those cold feet.
• Designer wireless remote control
COMPACT CASSETTE
Cassettes are extremely discreet, with only
the grille showing in the ceiling. They use
the latest fan technology to distribute the
conditioned air evenly.
• Wired remote control
(wireless is optional)
• Powerful turbo fan operation
• Fits into a standard 2’ x 2’ ceiling grid
Shown here is a 3-zone system using outdoor unit AOU36RLXFZ1.
6
7
FEATURES
A SOLUTION FOR ALL OF YOUR COMFORT NEEDS
ENERGY EFFICIENT: THE SMART CHOICE IN COMFORT
DUCTLESS TECHNOLOGY
As much as half of the energy used in your home goes to heating and cooling. So, making
smart decisions about your home’s heating and air conditioning system can have a big
effect on your utility bills — and your comfort.
CENTRAL AIR SYSTEM VERSUS FUJITSU HFI QUAD ZONE
Don’t waste money cooling and heating the ducts in your
walls and attic. Fujitsu systems are ductless, meaning they
install easily and won’t take up valuable closet space. Since
mini-splits have little to no ducting, they forego those energy
losses typically associated with central forced-air systems.
Duct losses in a central air system can easily account for
more than 30% of energy consumption, especially if the
ducts are not sealed tight or in an unconditioned space such
as an attic or crawlspace.
Thick black lines
represent ducts
of a central air
system.
Red lines
represent miniducts of a Fujitsu
Quad Zone
Slim Duct
System.
The high energy efficiencies
of Halcyon systems slash
utility bills by up to 25%. If
your average annual utilities
are $4,200, Fujitsu can save
you up to $1,050 annually or
$10,500 in 10 yrs!*
*Savings may vary based on model selected, hours of operation and
geographical location. Example given based on 33-SEER system
versus 14-SEER system.
WHOLE HOME OR BUSINESS COMFORT
Fujitsu’s Halcyon HFI systems provide home and business
owners just the right amount of heating and cooling needed
by installing 2 to 8 indoor units connected to one outdoor
unit. Indoor units vary by size and style and each creates its
own “zone” of comfort, allowing you to heat or cool individual
rooms, hallways and open spaces.
WHERE DOES MY MONEY GO?
Bedroom 1
72°F
Kitchen
74°F
Stay Cool.
68°F
Dining
Room
70°F
Stay Warm.
50%
Refrigerator
Dishwasher
5%
2%
Washer/
Dryer 6%
Lighting
10%
To encourage customers to buy energy efficient products,
many local utility companies offer significant rebates for
the purchase of a ductless mini-split system. Go to Fujitsu’s
web site to search for local rebates and consumer loans.
We provide a listing of rebates and offerings on qualifying
Fujitsu mini-splits by zip code.
www.fujitsugeneral.com
Electronics
8%
Other
Fujitsu
saves up to
25% on your
utility bill
ENERGY STAR® QUALIFIED SYSTEMS
If your HVAC equipment is more than 10 years old or not
keeping your house comfortable, you should have it looked
at by a professional HVAC contractor. If it is not performing
efficiently or needs upgrading, consider replacing it with a
unit that has earned ENERGY STAR®. Installed correctly, these
high-efficiency heating and cooling units can save up to
25% on heating and cooling costs.
A YEAR ROUND SOLUTION
Revolutionary Halcyon heat pumps provide both heating and
cooling for year round comfort in most climates. A simple
push of a button on the remote control allows you to switch
from heating to cooling (or vice versa) automatically.
Stay Comfortable.
Fujitsu has 30 systems that are ENERGY STAR qualified in
2018. See the lineup chart on pages 18-19 for a full listing of
all ENERGY STAR® qualified systems.
OTHER APPLICATIONS
SEER ...... •
The 30RLXEH is specially engineered for spaces such as
server rooms which require constant cool temperatures
year round, and rooms that hold a large number of people
(meeting spaces, classrooms, conference rooms).
EER ........ •
8
13%
7%
REBATES
Bedroom 2
Heating &
Cooling
Water Heater
HSPF...... •
9
FEATURES
COMFORT AND CONVENIENCE
APPLICATIONS
FLEXIBLE AND QUIET
Mini splits offer
flexibility because they
can be suspended from
a ceiling, mounted
flush behind a drop
ceiling, hung on a
wall or floor-standing.
Ductless heat pumps
allow for a peaceful
inside environment by
enabling the contractor
to install components
like compressors and
motors outdoors.
dB(A) Level
140
105
WHERE CAN
MINI-SPLITS
BE USED?
Jet Engine at
100’
Power
Tools
70
Normal
Conversation
from 3 - 5’
35
Whisper
Quiet
Library
0
Weakest
Sound
Heard
Convenience stores
Fast food chains
Fujitsu
Indoor
Units
21~49
dB(A)
CONSTANT COMFORT
THROUGH INVERTER TECHNOLOGY
Inverter technology is like cruise control for your heating or
cooling system. Compressors only run as fast as they need
to handle the cooling or heating demand. They can handle
greater extremes in temperature, are smoother and more
stable in operation, and reach the desired temperature more
quickly than conventional air conditioners.
Fire houses
Police stations
Set
Temp.
Bars
Sunrooms and additions
Warehouses
Temp.
Nursing homes
Small offices
Conventional
System
Set
Temp.
Inverter Benefits
• Up
temperature in half the time
Hospitals and
medical facilities
Temp.
to 30% more efficient
• Stable
Restaurants
temperature
USER FRIENDLY CONTROL
Fujitsu is using ergonomics to expand the use of user friendly
designs such as easy-to-read large LCD displays, easy-tooperate buttons, and displays with easily recognizable colors
and icons. We are producing control systems that provide
greater convenience for both individual and centralized
control with operability suitable for the application.
Optional Wired
Remote
UTY-RVNUM
10
Places of worship
RPMs = quieter operation
• Desired
New construction homes
Schools
• More heat at lower outdoor temperatures
• Lower
Older homes
Standard
Wireless
Remote
for select
systems
Inverter System
Computer rooms
Hotels and motels
ATM vestibules
Server rooms
JUST ABOUT ANY
PLACE THAT
REQUIRES
COMFORT!
11
FEATURES
FUJITSU HALCYON WIFI SELECTION GUIDE
FGLair¬ APP
Control your home’s climate anytime, anywhere!
WIFI CONNECTABLE UNITS & MODULES
FGLAir¬
Access control functions remotely from any smartphone or tablet.
IntesisHome¬
RLS3Y & RLS3YH (Built In)
WIFI Interface Module
IR Wireless Module
Wired Module
ASU 9/12/15 RLS3Y
UTY-TFNXZ2 (Add-on)
FJ-IR-WIFI-1NA (Add-on)
FJ-RC-WIFI-1NA (Add-on)
SLIM DUCT
WALL UNIT
WHICH APP DOES IT USE?
FGLAir¬
IntesisHome¬
¬
INTESISHOME¬ APP FEATURES:
FGLAIR APP FEATURES:
• On/Off
• Change Mode
• Change Temp Setpoint
• Fan Speed
• Louver/Swing Position
• Weekly Timer
• Economy Setting
• Emailed Error Alerts
App available on iOS and Android.
• On/Off
• Change Mode
• Change Temp Setpoint
• Fan Speed
• Louver/Swing Position
• Weekly Timer
• Fully Programmable
• Alarm Notifications
App available on iOS and Android. Can also be run through a web browser.
WHERE DOES IT MOUNT?
CEILING CASSETTE
Set minimum heat
Second house
USER FRIENDLY INTERFACE
Check operation
Off
On
Check operation
User friendly screen display facilitates
easy operation.
Control up to 24 systems using a single free account.
Room temperature*
Temperature setting
Operation mode
Up to 20’ away from IDU
On the wall next to IDU
WALL MOUNTS:
WALL MOUNTS:
WALL MOUNTS:
WALL MOUNTS:
ASU9RLS3Y
ASU 7 / 9 / 12RLF¹
ASU 7 / 9 / 12RLF
$685/)Ɖ,Ɗ
ASU12RLS3Y
ASU 7 / 9 / 12 / 15RLF1²
ASU 7 / 9 / 12 / 15RLF1
$685/)Ɖ,Ɗ
ASU15RLS3Y
ASU 9 / 12 / 15RLS2³
ASU 9 / 12 / 15RLS2
$685/6Ɖ,Ƌ
ASU 9 / 12 / 15RLS3³
ASU 9 / 12 / 15RLS3
$685/6Ɖ,Ƌ
ASU 18 / 24RLF
ASU 18 / 24RLF
ASU 18 / 24RLF
ASU 30 / 36CLX1
ASU 30 / 36CLX1
ASU 30 / 36CLX1
ASU30RLX
ASU30RLX
ASU30RLX
ASU 18 / 24RLB
ASU 18 / 24RLB
ASU 18 / 24RLB
ASU 30 / 36RLXB
ASU 30 / 36RLXB
ASU 30 / 36RLXB
ASU30RLE
ASU 9/12RL2
ASU 18CL / 24CL1
ASU 18CL / 24CL1
Individual AC name display
ON/OFF button
On the wall next to IDU
COMPATIBLE UNITS:
Change
temperature
FLOOR UNIT
Built into the RLS3Y
CASSETTES:
CASSETTES:
AUU 7 / 9 / 12 / 18RLF
AUU 7 / 9 / 12 / 18RLF
DUCTED:
DUCTED:
DUCTED:
ARU 7 / 9 / 12 / 18 / 24RLF
$585/)Ƈ
ARU 7 / 9 / 12 / 18 / 24RLF
AUU 18 / 24 / 36 / 42RCLX
MAIN FUNCTIONS
• ON / OFF
• Operation mode
• Fan speed
• Louver position
• Set temperature control
CASSETTES:
AUU 7 / 9 / 12 / 18RLF
• Weekly timer
• Minimum heat
• ESP function
• Error display
‡(PDLOQRWLÀFDWLRQ
FLOOR MOUNTS:
FLOOR MOUNTS:
FLOOR MOUNTS:
AGU 9 / 12 / 15RLF
AGU 9 / 12 / 15RLF
$*85/)Ɖ
UNIVERSAL / CEILING:
UNIVERSAL / CEILING:
ABU 18 / 24RULX
ABU 18 / 24RULX
ABU36RSLX
ABU36RSLX
UTY-TFNXZ2 cannot be installed
in conjunction with Wired
Remote Controls.
¹ requires UTY-XCBXZ1
*Only applies to RLS3Y units. Feature not available with Wi-Fi module
(UTY-TFNXZ2).
ƇUHTXLUHV87</5+80
ƉUHTXLUHV87<:,),
² requires UTY-XCBXZ2
ƊUHTXLUHV87<;&%;=
³ requires UTY-TWBXF1
ƋUHTXLUHV87<7:%;)
is worldwide trademark of FUJITSU GENERAL LIMITED.
12
13
FEATURES
EXTRA LOW TEMPERATURE HEATING - XLTH
FEATURE EXPLANATION
CONVENIENCE
ENERGY SAVING
NOT ALL HEATING SYSTEMS ARE CREATED EQUAL
Without the right technology, a system won’t work when its needed most.
SEER
6HDVRQDO(QHUJ\(IÀFLHQF\5DWLQJ8VHGWRH[SUHVVHIÀFLHQF\RIDQ$&RU+HDW
3XPS$KLJKHUUDWLQJPHDQVPRUHHIÀFLHQW
HSPF
+HDWLQJ6HDVRQDO3HUIRUPDQFH)DFWRUPHDVXUHVWKHHIÀFLHQF\RIKHDWLQJ
portion of your heat pump.
PROTECTION FROM WINTERS’
COLDEST TEMPERATURES
When the temperature drops you don’t want to be left in
the cold. It’s important to choose a heat pump system rated
for the climate you live in. If your system doesn’t operate in
severe conditions you and your family could be left without
any heat at all.
Fujitsu’s line of mini-split heat pumps come in different
sizes, styles, and rated outdoor temperatures. The Extra Low
) Series features outdoor
Temperature Heating (
condensing units engineered to operate in temperatures
down to -15°F.
Economy
Saving
HIGH PERFORMANCE HEATING
Fujitsu XLTH units feature large heat exchangers and high
capacity compressors. This gives our XLTH heat pumps the
ability to extract heat even at very low outdoor temperatures.
For example, at an indoor setpoint of 70°F, all RLS3YH and
RLFFH models can deliver 100% or more of their rated heating
capacity down to 3°F. All XLTH models also offer superior
heating performance down to -15°F outdoor temperatures.
ESP
Economy Mode
Thermostat setting automatically changes according to the temperature to
avoid unnecessary cooling and heating.
Energy Saving Program (ESP)
If a space is left without turning the unit off, ESP knows that it is unoccupied
and 20 minutes later, temperature is adjusted accordingly until users return to
the room. Function is disable in multi-zone installations.
Auto
Changeover
Adjust
While other models have a plastic fan guard, XLTH models
use metal, which is most capable of withstanding the colder
elements.
4-Way
Up/Down
Restart
Dry
Without the right technology, condensate freezes to the bottom of
the unit and reduces its efficiency and heating output.
Fresh
Low Noise
IMPROVED HEATING CAPACITY
Heating capacity at low outdoor temperatures was improved
by adopting a large heat exchanger and a high capacity
compressor.
% of Heating Capacity
100
Standard
Series
50
47°
“H”
Series
Models
5°
Ambient Temperature (F°)
14
-15°
BASE PAN HEATER
• Equipped with a heater that prevents condensate from
freezing
• Contoured base design discharges melted water through
drain holes.
• Without a heater,
freezing condensate
can cause noise,
damage to fan blade,
condenser, and system
performance.
Drain Holes
Base Heater
Weekly
Powerful
Quiet Mode
Auto Fan Mode
System starts in high fan speed and automatically adjusts downward as room
begins to reach set temperature.
Cold
100%
@
+5°F
Ion
Pump Down
Sensor
I/O
Auto Louver: 4 Way
5HGLUHFWVDLUÁRZDXWRPDWLFDOO\ZLWKXSGRZQDQGOHIWULJKWPRWLRQ
3rd Party
Auto Louver: Up/Down
5HGLUHFWVDLUÁRZDXWRPDWLFDOO\ZLWKVHYHQSRVLWLRQXSDQGGRZQPRWLRQZKLFK
can be set to auto swing.
Cooling
Auto Restart
Following a power failure, systems will automatically restart in the same
operating mode as before, once power has been restored.
Outdoor Unit Low Noise+
Limits compressor and fan speed during high speed operation for noise
reduction purposes.
Powerful Operation
PLQXWHVRIFRQWLQXRXVRSHUDWLRQDWPD[LPXPDLUÁRZDQGPD[LPXP
compressor speed. Rapid cooling and heating makes the room comfortable
quickly.
Quiet Mode (Indoor Unit)
An extra quiet fan speed to make sure you are not disturbed.
+ Function is bypassed during defrost and at low speed operation. This feature may limit cooling/
heating capacity during high/low ambient conditions and increase energy consumption as system
may need to operate longer due to reduced compressor speed.
* Auto Changeover is not designed to provide rapid changes between heating and cooling operation
or simultaneous heating and cooling. This feature is not recommended for systems with more than
one indoor unit unless all indoor units have similar heating and cooling requirements and have
similar temperature set points. If all indoor units have similar heating and cooling requirements and
have similar temperature set points, auto changeover will work.
Weekly Timer
Allows you to set on/off time twice a day and a different on/off time by day.
Cold Prevention
Indoor coil will warm prior to fan operating, preventing cold air during heating
mode.
Expanded Heating Performance
Delivers 100% of rated heating capacity at +5°F (-15°C).
High Ceiling Mode
Temperature at the top of a high ceiling room may be warmer than the space
occupied; this mode adjusts for this difference.
Ion Deodorizing Filter
Deodorizes by decomposing absorbed odors using the oxidizing and reducing
HIIHFWVRILRQVJHQHUDWHGE\ÀQHFHUDPLFSDUWLFOHV\HDUOLIHH[SHFWDQF\:DVK
to restore surface action.
Pump Down Operation
Collects all refrigerant in system back into the outdoor unit when the unit is to
be moved or before servicing the refrigerant circuit.
Remote Temperature Sensor
Room temperature sensor is located in optional wired remote control only.
Third Party Device Control
Turns system on or off using a normally closed circuit. Interface with third party
devices such as home automation.
0˚F
0°F Low Ambient Cooling
Can operate in cooling mode with outdoor temperatures as low as 0°F.
2SHUDWLRQRXWVLGHRIIDFWRU\VSHFLÀFDWLRQLVQRWUHFRPPHQGHG
-5˚F
-5°F Low Ambient Cooling
Can operate in cooling mode with outdoor temperatures down to -5°F.
2SHUDWLRQRXWVLGHRIIDFWRU\VSHFLÀFDWLRQLVQRWUHFRPPHQGHG
Cooling
INSTALLATION
Dry Mode
This mode gives priority to reducing the level of humidity in the room, in
conjunction with lowering the temperature.
Fresh Air Intake
2XWVLGHDLUFDQEHLQWURGXFHGE\DWWDFKLQJÀHOGVXSSOLHGÁH[LEOHGXFWWRIUHVK
air knockouts.
Sleep Timer
Automatically adjusts the temperature while you sleep to make you more
comfortable.
Apple Catechin Filter (polyphenol ingredient from apples)
'XVWPROGVSRUHVDQGPLFURRUJDQLVPVDUHDEVRUEHGRQWRWKHÀOWHUE\VWDWLF
electricity and growth is inhibited. 3 - 12 month life expectancy.
Minimum Heat Mode
Sets room temperature to 50°F, keeping temperatures above freezing and
reducing power consumption.
Auto Changeover (heating to cooling or vice-versa)*
Automatically alternates between heating or cooling if the room temperature
IDOOVÝ)EHORZWKHVHWWHPSHUDWXUHZKHQFRROLQJorULVHVÝ)DERYHVHW
temperature when heating.
24 Hour Timer
Allows for one on/off cycle during a 24 hour period.
PERFORMANCE
Ceiling
COMFORT
METAL FAN GUARD
Sleep
Energy Saver
Keeps room cool enough for comfort by using a relaxed thermostat setting
reducing power consumption.
ENERGY STAR® Qualified
4XDOLÀHGSURGXFWVDQGSUDFWLFHVKHOS\RXVDYHPRQH\DQGUHGXFHJUHHQKRXVH
JDVHPLVVLRQVE\PHHWLQJVWULFWHQHUJ\HIÀFLHQF\JXLGHOLQHVVHWE\WKH86
Environmental Protection Agency and the U.S. Department of Energy.
Minimum Heat
Fujitsu XLTH systems do not have a low
temperature lockout, continuing to heat
even below -15°F as conditions allow.
24 Hour
Heater
Blue Fin
Branch
Pump
16
Daisy
164+ ft
Piping
Slender
Base Pan Heater
Prevents condensate from freezing on the outdoor unit.
Blue Fin Heat Exchanger
%OXHÀQWUHDWPHQWWRWKHRXWGRRUXQLW·VKHDWH[FKDQJHULPSURYHVFRUURVLRQ
resistance.
Branch Duct Capable
6\VWHPVDUHFDSDEOHRIDWWDFKLQJÀHOGVXSSOLHGEUDQFKGXFWVSURYLGLQJXSWR
38% of the cooling up to 16 feet away.
Built-In Condensate Pump
Integrated into the indoor unit.
Daisy Chain
Ability to connect up to 16 identical style indoor units to one wired remote.
Long Piping Length
Long piping lengths between indoor and outdoor units provides flexibility and
increased applications.
Slender Fit
Cassette body can be moved downward into the room 1-3/8” to accommodate
limited ceiling space.
6/2 7/5
Warranty
Warranty
Standard Warranty
Fujitsu systems come standard with either a 6 Year Compressor / 2 Year
Parts warranty or a 7 Year Compressor / 5 Year Parts warranty.
Extended Warranty
Additional info on page 71. See full product warranty for details.
15
9.0
33.0
14.0
33.0
14.2
23.0
16.0
11.0
9.0
z z z
Minimum Heat Mode
@
-5˚F
-5° Low Ambient Clg.
z z z z z z z z
z z
z z
z z z z z z z z z z z z z
z z z z z z z z z
z z z
z z z z
z z z z
z
z
z z z z z z
z z z z z
z
z
z z z z z z
z z z z z z z z z z z z z z z z z z z z
‡ z z z z ‡ ‡ z ‡ ‡ z z ‡ ‡ ‡ ‡ ‡ ‡ ‡ ‡ z z z z z z ‡ ‡ ‡ z z z z
z z z
z z z
z z
z z z
z
z
z
z z z
z z z z z z
z z z z z z z
z z z z z z z
z
z z
z
z z z z z
z z
z z z
z
z
z
z z z z z z
{ { { { { {
z z z z
z z z z
z z z z z z z
z z
z z z z z
z z z z z z z
z z z z
z z z z z z z
„ „ „ „ „ ‡ ‡ ‡ ‡ ‡ ‡ ‡ ‡ ‡ ‡ ‡ ‡ ‡ ‡ ‡ z z z z z z z z z z z z z
z
z z
{ { { { { { { { { { { { { {
„ „ „ „ „ ‡ ‡ ‡ ‡ ‡ ‡ ‡ ‡ ‡ ‡ ‡ ‡ ‡ ‡ ‡ z z z z z z ‡ ‡ ‡ z z z z
z
z z z z z z z z z z z z z z z z z z z z
z z z z
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
„ „ „
z
{ { {
„ „ „
z z z
z z
z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z
z z z
‡ z z
z z z z z z z z z z z z z z z z z z z z z z z z z
z z z
z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z
z z z z z z z z z z
z z
¡ ¡ ¡ z z z z z z z z z z
z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z
z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z
z z
z z
z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z
MULTI-ZONE
HEAT PUMPS
1

„
z
{
„
z
z
z
‡
z
z
z
z
z
z
z
z+
z
z*
z
S S z
z z z
1

‡
z
{
‡
z
z
z
‡
z
z
z
z
z
z
z
z
z
1 1 1
  
z z ‡
z z
z z z
{ { {
z z ‡
z
z z z
z
z z ‡
S S z
S S z
z z z
z ¡
z z z
z z z
z z
z z z
z+ z+ z+ z
z
z
‡ Available only with optional wired remote control.
„ Available only with optional wired remote controller and optional Interface Kit.
S Available only with optional wireless remote control.
{ Available only with optional Interface Kit. Operation monitoring and On/Off control only.
¡ Available only with optional Fresh Air Intake Kit.

* See bottom of Page 17 for qualifying combinations.
** Operation monitoring and On/Off control only.
^ SEER and HSPF ratings depend on combination of indoor units and outdoor unit selected.
+ Auto Changeover is not designed to provide rapid changes between heating and cooling operation or simultaneous heating and cooling. This feature is not recommended for
systems with more than one indoor unit unless all indoor units have similar heating and cooling requirements and have similar temperature set points. If all indoor units have
similar heating and cooling requirements and have similar temperature set points, auto changeover will work.
1 Standard warranty is 5 year Compressor / 7 year Parts. 12 year Compressor/Parts warranty applies when properly registered AND installed by a Fujitsu Elite Contractor in a
residence. See full warranty for details.
Warranty: up to 12 Yr Comp / Parts
Warranty
6/2
Slender
Slender Fit
Warranty: 6 Yr Comp / 2 Yr Parts
Piping
Long Piping Length (164’+)
164+ ft
Daisy
16
Pump
Built-In Condensate Pump
Daisy Chain
Branch
Branch Duct Capable
Blue Fin
Blue Fin Coil Protection
Heater
Base Pan Heater
Cooling
0˚F
Cooling
3rd Party
I/O
Sensor
Pump Down
Ion
Ceiling
+5°F
0° Low Ambient Clg.
Third Party Device Control
Remote Temp. Sensor
Pump Down Operation
Ion Deodorizing Filter
High Ceiling Mode
Expanded Htg. Performance
Cold
100%
z z z
z
z z z z z z z z z z z z z z z z z z z z S S S S S S
z z z z z z z z
z z z z
z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z
z z z
z z
ENERGY STAR® Qualified
11.0
Cold Prevention
14.0
22.0
Apple Catechin Filter
13.8
29.3
Weekly
29.3
Weekly Timer
13.4
Sleep
13.3
25.3
Sleep Timer
25.3
24 Hour
10.6
24 Hour Timer
10.5
19.0
Quiet Mode
20.0
Quiet Mode (Indoor Unit)
10.4
Powerful
10.6
20.0
Powerful Operation
10.6
18.0
Low Noise
19.5
Outdoor Unit Low Noise
10.0
Fresh
11.7
19.5
Fresh Air Intake
18.7
Dry
9.0
9.0
Dry Mode
15.5
16.5
12.4
12.6
Restart
11.6
26.0
26.0
Auto Restart
22.7
Up/Down
11.3
Auto Louver: Up/ Down
22.7
4-Way
11.0
11.2
Auto Louver: 4 Way
20.3
20.3
Adjust
11.5
12.2
13.0
Auto Fan Mode
20.1
21.9
24.0
Changeover
11.3
11.5
12.2
Auto Changeover
19.7
20.0
21.2
Auto
8.5
8.5
8.5
‡ ‡ ‡ z z z z
14.0
15.0
16.0
z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z
16.0
HSPF
8.5
8.5
Minimum Heat
LARGE
CASSETTE
15.0
16.0
ESP
FLOOR /
CEILING
UNIVERSAL
8.5
8.5
Saving
SLIM
DUCT
15.0
14.0
Energy Saver
COMPACT
CASSETTE
Compact Wall 21.5^ 10.3^
Economy
FLOOR MOUNT
(RLF1: 7-15k BTU)
Economy Mode
WALL MOUNT
SINGLE-ZONE HEAT PUMPS
42RCLX
36RCLX
24RCLX
18RCLX
36RSLX
24RULX
18RULX
18RLFCD
12RLFCD
9RLFCD
18RLFCC
12RLFCC
9RLFCC
15RLFFH
15RLFF
12RLFFH
12RLFF
9RLFFH
9RLFF
36RLXB
30RLXB
30RLXEH
24RLXFWH
24RLXFW1
24RLB
18RLXFWH
18RLXFW1
18RLB
15RLS3YH
15RLS3Y
12RLS3YH
12RLS3Y
12RLFW1
12RL2
9RLS3YH
9RLS3Y
9RLFW1
9RL2
SEER
SYSTEM
FEATURE
SUMMARY
(RLF: 18, 24k BTU)
Slim Duct 14.7^ 9.3^
Large Wall 21.5^ 10.3^
Energy Saving Pgm (ESP)
16
Floor Mount 21.5^ 10.3^
Cassette 21.5^ 10.3^
17
MODEL LINEUP
SINGLE-ZONE AND MULTI-ZONE SYSTEMS LINEUP
Minimum Ambient Cooling Temperature:
Minimum Ambient Heating Temperature:
SINGLE ZONE DUCTLESS HEAT PUMP SYSTEMS
BTU
9,000
12,000
15,000
14 °F
-5°F
Wall Mount
Highest SEER
ASU9RLS3Y / AOU9RLS3
Wall Mount
14°F
-5°F
ASU12RLS3Y / AOU12RLS3
14 °F
-15°F
Highest SEER plus
ASU9RLS3Y / AOU9RLS3H
High SEER
Entry Level
Horizontal/Vertical
14°F
5°F
ASU24RLB / AOU24RLB
14°F
5°F
ASU30RLXB / AOU30RLXB
14°F
5°F
ASU36RLXB / AOU36RLXB
AGU15RLF / AOU15RLFF
14°F
-15°F
AGU15RLF / AOU15RLFFH
14°F
-5°F
AUU18RLF / AOU18RLFC
AUU12RLF / AOU12RLFC
14°F
-5°F
14°F
-5°F
ARU9RLF / AOU9RLFC
ASU30RLE / AOU30RLXEH
14°F
-5°F
14°F
-5°F
14°F
-5°F
Slim Duct
-5°F
-15°F
ASU24RLF / AOU24RLXFW1
ASU18RLB / AOU18RLB
AGU12RLF / AOU12RLFFH
AUU9RLF / AOU9RLFC
42,000
-5°F
-5°F
14°F
5°F
14°F
-15°F
14°F
-5°F
Compact Cassette
ASU24RLF / AOU24RLXFWH
ASU18RLF / AOU18RLXFW1
AGU12RLF / AOU12RLFF
AGU9RLF / AOU9RLFFH
36,000
-5°F
-15°F
-5°F
-5°F
14°F
-5°F
14°F
-15°F
Highest SEER plus
ASU18RLF / AOU18RLXFWH
ASU12RL2 / AOU12RL2
AGU9RLF / AOU9RLFF
Floor Mount
-5°F
-15°F
15°F
15°F
14°F
-5°F
Highest SEER
ASU15RLS3Y / AOU15RLS3H
ASU12RLF1 / AOU12RLFW1
ASU9RL2 / AOU9RL2
Floor Mount
14 °F
-15°F
14°F
5°F
15°F
15°F
Wall Mount
30,000
ASU15RLS3Y / AOU15RLS3
ASU12RLS3Y / AOU12RLS3H
ASU9RLF1 / AOU9RLFW1
24,000
14°F
-5°F
14 °F
-15°F
14°F
5°F
Wall Mount
18,000
ARU18RLF / AOU18RLFC
ARU12RLF / AOU12RLFC
0°F
14°F
Universal Mount
Floor/Ceiling
0°F
14°F
ABU18RULX / AOU18RLX
ABU24RULX / AOU24RLX
0°F
14°F
Ceiling Suspended
ABU36RSLX / AOU36RLX
0°F
14°F
Large Cassette
0°F
14°F
AUU18RCLX / AOU18RLX
MULTI ZONE DUCTLESS HEAT PUMPS - INDOOR UNITS
BTU
Compact
Wall Mount
0°F
14°F
AUU24RCLX / AOU24RLX
0°F
0°F
AUU36RCLX / AOU36RLX
AUU42RCLX / AOU42RLX
MULTI ZONE DUCTLESS HEAT PUMPS- OUTDOOR UNITS
7,000
9,000
12,000
15,000
ASU7RLF1
ASU9RLF1
ASU12RLF1
ASU15RLF1
18,000
24,000
BTU
18,000
(2 Indoor Units)
14°F
5°F
+
Large
Wall Mount
ASU18RLF
ASU24RLF
ARU24RLF
24,000
(2 - 3 Indoor Units)
36,000
(2* - 4 Indoor Units)
14°F
5°F
+
AOU18RLXFZ
AOU24RLXFZ
14°F
5°F
AOU36RLXFZ1
45,000
(2 - 5 Indoor Units)
48,000
(2 - 8 Indoor Units)
14°F
5°F
AOU45RLXFZ
23°F
5°F
AOU48RLXFZ1
Slim Duct
Compact
Cassette
ARU7RLF
ARU9RLF
ARU12RLF
ARU18RLF
AUU7RLF
AUU9RLF
AUU12RLF
AUU18RLF
Floor Mount
AGU9RLF
18
AGU12RLF
AGU15RLF
+
AOU18RLXFZH
14°F
-15°F
+
AOU24RLXFZH
14°F
-15°F
+
14°F
-15°F
AOU36RLXFZH
* If AOU36RLXFZ1 is paired with two 18,000 BTU indoor units, you have to purchase optional kit Part #K9FZ1818.
+ The only combinations that qualify for ENERGY STAR® are:
AOU18RLXFZ with (2) ASU9RLF1
AOU18RLXFZH with (2) ASU9RLF1
AOU18RLXFZ with (1) ASU7RLF1 + (1) ASU12RLF1
AOU24RLXFZ with (2) ASU7RLF1 + (1) ASU9RLF1
AOU18RLXFZ with (1) ASU9RLF1 + (1) ASU12RLF1
AOU24RLXFZH with (2) ASU7RLF1 + (1) ASU9RLF1
AOU36RLXFZH with (4) ASU9RLF1
19
FEATURES
SINGLE-ZONE
MINI-SPLITS
SINGLE-ZONE MINI-SPLIT SYSTEMS
Making the hottest places cool
and the coolest places
more comfortable
HIGH HEAT
ENERGY SAVING PROGRAM
These Halcyon systems know how
to save you money even when
you forget. If you leave the room
without turning the unit off,
ESP knows that you left and 20
minutes later, set temperature
is increased by 4°F when cooling and reduced
by 8°F when heating. When you come back to the room, it
returns to previous operating mode.This prevents wasteful
operation to save energy without you having to think about
it. This feature can be deactivated if chosen.
HIGH PERFORMANCE HEATING
The RLS3Y model can operate down to -5°F. The RLS3YH can
operate down to -15°F. See the full
story on page 14.
20
14,500
3,100~18,400
18,000
3,100~23,900
25.3
13.3
13.9
14~115 (-10~46)
-15~75 (-26~24)
4.0 (1.9)
140%
124%
109%
I/O
3rd Party
3
Powerful
Low Noise
2
4
16
Heater
Daisy
BUILT-IN WI-FI
Remotely operate
your heating and
cooling system using
a smartphone as
a remote control.
Details on page 12.
OPTIONAL ACCESSORIES
• Wired Remote Control: UTY-RVNUM
• Wired Remote Control: UTY-RNNUM
• Simple Remote Control: UTY-RSNUM
• Interface Kit: UTY-TWBXF1
• Dry Contact Wire Kit: UTY-XWZXZ5
Quiet Mode
°F (°C)
°F (°C)
Pt./h (l/h)
489 (830)
400 (680)
341 (580)
489 (830)
400 (680)
341 (580)
224 (380)
224 (380)
4+Auto
4+Auto
547 (930)
459 (780)
371 (630)
Clg 259 (440)
Htg 294 (500)
4+Auto
24 Hour
Fan
Air Circulation: Hi
Medium
Low
CFM (m3/h)
CFM (m3/h)
CFM (m3/h)
489 (830)
400 (680)
341 (580)
489 (830)
400 (680)
341 (580)
Quiet
CFM (m3/h)
224 (380)
224 (380)
4+Auto
4+Auto
547 (930)
459 (780)
371 (630)
Clg 259 (440)
Htg 294 (500)
4+Auto
42/41
37/35
32/31
23/23
42/47
42/41
37/35
32/31
23/23
43/47
45/45
40/39
34/33
26/27
49/50
42/41
37/35
32/31
23/23
42/47
42/41
37/35
32/31
23/23
43/47
45/45
40/39
34/33
26/27
49/50
208-230/60/1
Fan Speed Stage
Sound
Indoor Level (Clg/Htg): Hi
Medium
Low
Quiet
Outdoor Level Clg/Htg
Electrical
Voltage/Frequency/Phase
dB(A)
dB(A)
dB(A)
dB(A)
dB(A)
208-230/60/1
208-230/60/1
208-230/60/1
208-230/60/1
208-230/60/1
Circuit Breaker
Amps
15
15
20
15
15
20
Current Rated/Max: Cooling
Amps
2.5/9.4
3.8/9.4
4.8/9.9
2.5/9.4
3.8/9.4
4.8/9.9
Current Rated/Max: Heating
Amps
3.3/10.0
4.7/11.9
5.2/13.9
3.3/10.0
4.7/11.9
5.2/13.9
Power Use Rated/Max: Cooling
kW
0.50/0.85
0.79/0.99
1.04/1.56
0.50/0.85
0.79/0.99
1.04/1.56
Power Use Rated/Max: Heating
Size & Weight
Net Weight
kW
0.66/1.93
1.01/1.94
1.15/2.19
0.66/1.93
1.01/1.94
1.15/2.19
Dimensions: Height
Width
Depth
lbs. (kg)
Inch
mm
Inch
mm
Inch
mm
Refrigerant
Additional Data
Air Direction: Horizontal
Vertical
Air Filter
Minimum Lineset Length
Ft (m)
Maximum Lineset Length
Max. Vertical Diff.
Lineset Size
31 (14) 84 (38) 31 (14) 84 (38) 31 (14) 86 (39)
11-5/8 24-7/16 11-5/8 24-7/16 11-5/8 24-7/16
295
620
295
620
295
620
37
31-1/8
37
31-1/8
37
31-1/8
940
790
940
790
940
790
10-5/8 11-7/16 10-5/8 11-7/16 10-5/8 11-7/16
270
290
270
290
270
290
R410A
R410A
R410A
31 (14) 86 (39)
11-5/8 24-7/16
295
620
37
31-1/8
940
790
10-5/8 11-7/16
270
290
R410A
31 (14) 86 (39) 31 (14) 88 (40)
11-5/8 24-7/16 11-5/8 24-7/16
295
620
295
620
37
31-1/8
37
31-1/8
940
790
940
790
10-5/8 11-7/16 10-5/8 11-7/16
270
290
270
290
R410A
R410A
Automatic
Automatic
Washable
10 (3)
Automatic
Automatic
Washable
10 (3)
Automatic
Automatic
Washable
10 (3)
Automatic
Automatic
Washable
10 (3)
Automatic
Automatic
Washable
10 (3)
Automatic
Automatic
Washable
10 (3)
Ft (m)
66 (20)
(pre-charge: 49’)
66 (20)
(pre-charge: 49’)
66 (20)
(pre-charge: 49’)
66 (20)
(pre-charge: 49’)
66 (20)
(pre-charge: 49’)
66 (20)
(pre-charge: 49’)
Ft (m)
Inch
49 (15)
Suc.3/8 Dis.1/4
49 (15)
Suc.3/8 Dis.1/4
49 (15)
Suc.1/2 Dis.1/4
49 (15)
Suc.3/8 Dis.1/4
49 (15)
Suc.3/8 Dis.1/4
49 (15)
Suc.1/2 Dis.1/4
* Based on model # capacity class (e.g. 9RLS3Y
based on 9,000 BTUh) @ 70°F indoor setpoint.
Refer to the Design & Technical Manual for
more heating capacity data.
Outdoor
AOU15RLS3H
1 Applies when properly registered AND installed by a Fujitsu Elite Contractor in a
residence. See full warranty for details.
2 Available only with optional wired Remote Control and optional interface kit.
3 Available only with optional interface kit. Operation monitoring and On/Off control
only.
4 XLTH models only
12,000
3,100~13,600
16,000
3,100~22,100
29.3
13.8
15.2
14~115 (-10~46)
-15~75 (-26~24)
2.7 (1.3)
138%
125%
98%
Indoor
ASU15RLS3Y
Sensor
9,000
3,100~12,000
12,000
3,100~22,000
33.0
14.0
18.0
14~115 (-10~46)
-15~75 (-26~24)
2.6 (1.2)
171%
156%
123%
Outdoor
AOU12RLS3H
Ion
14,500
3,100~18,400
18,000
3,100~23,900
25.3
13.4
13.9
14~115 (-10~46)
-5~75 (-21~24)
4.0 (1.9)
140%
124%
--
Indoor
ASU12RLS3Y
@
+5°F
Dry
Restart
2
100%
12,000
3,100~13,600
16,000
3,100~22,100
29.3
14.0
15.2
14~115 (-10~46)
-5~75 (-21~24)
2.7 (1.3)
138%
125%
--
Outdoor
AOU9RLS3H
4-Way
9,000
3,100~12,000
12,000
3,100~22,000
33.0
14.2
18.0
14~115 (-10~46)
-5~75 (-21~24)
2.6 (1.2)
171%
156%
--
Indoor
ASU9RLS3Y
Cold
Adjust
BTUh
BTUh
BTUh
BTUh
Outdoor
AOU15RLS3
Weekly
Changeover
15RLS3YH
Indoor
ASU15RLS3Y
Sleep
Auto
Performance
Nominal Cooling
Min.-Max. Cooling
Nominal Heating
Min.-Max. Heating
SEER
HSPF
EER
Cooling Operating Range
Heating Operating Range
Moisture Removal
0D[+WJRI0RGHO&DSDFLW\DWÝ) Ý&
0D[+WJRI0RGHO&DSDFLW\DWÝ) Ý&
0D[+WJRI0RGHO&DSDFLW\DWÝ) Ý&
Wi-Fi Enabled
Minimum Heat
12RLS3YH
Outdoor
AOU12RLS3
· Quiet operation with indoor units as low as 21dB and
outdoor units as low as 47dB
9, 12, 15,000 BTUh WALL MOUNT HEAT PUMPS
ESP
9RLS3YH
Indoor
ASU12RLS3Y
· All systems feature environmentally friendly R410A
refrigerant
Economy
15RLS3Y
Outdoor
AOU9RLS3
· 38 different systems available in 7 indoor unit styles
1
12RLS3Y
Indoor
ASU9RLS3Y
· Inverter Technology is used in all systems
· 25 ENERGY STAR® qualified systems
9RLS3Y
UP TO 33.0 SEER
· Extensive lineup from 9,000 to 42,000 BTU
· Energy efficient systems with SEER ratings as high as
33.0 and HSPF as high as 14.2
SYSTEMS 9RLS3Y, 12RLS3Y, 15RLS3Y
SYSTEMS 9RLS3YH, 12RLS3YH, 15RLS3YH
Note: Figures are based on 230 Volts.
21
MULTI-ZONE MINI-SPLITS
SINGLE-ZONE
MINI-SPLITS
9 AND 12,000 BTUh WALL MOUNT HEAT PUMPS
HFI
SYSTEMS 9RLFW1, 12RLFW1
9RLFW1
12RLFW1
9,000
1,700~10,900
12,000
1,700~15,000
23.0
11.0
13.8
14~115 (-10~46)
5~75 (-15~24)
2.75 (1.3)
12,000
3,100~13,300
16,000
3,100~19,100
22.0
11.0
12.5
14~115 (-10~46)
5~75 (-15~24)
3.80 (1.8)
441 (750)
376 (640)
282 (480) Clg
306 (520) Htg
182 (310) Clg
194 (330) Htg
4+Auto
441 (750)
376 (640)
282 (480) Clg
306 (520) Htg
182 (310) Clg
194 (330) Htg
4+Auto
dB(A)
dB(A)
dB(A)
dB(A)
dB(A)
43/43
40/38
32/33
21/22
48/48
43/43
40/38
32/33
21/22
49/49
Amps
Amps
Amps
kW
kW
208-230/60/1
20
3.2/6.0
4.2/7.5
0.65/1.27
0.89/1.60
208-230/60/1
20
4.4/6.5
5.9/9.0
0.96/1.40
1.28/1.99
UP TO 23 SEER
Cold
Minimum Heat
Adjust
Changeover
3
Ion
Sensor
Up/Down
4
I/O
Restart
Dry
Powerful
Quiet Mode
24 Hour
Sleep
Weekly
3
16
3rd Party
Daisy
1 Applies when properly registered AND installed by a Fujitsu Elite Contractor in a residence. See full warranty for details.
2 Available only with optional wired remote control.
3 Available only with optional wired remote control and optional interface kit.
4 Available only with optional interface kit. Operation monitoring and On/Off control only.
CFM (m3/h)
CFM (m3/h)
°F (°C)
°F (°C)
Pt./h (l/h)
BUILT IN FILTRATION
OPTIONAL ACCESSORIES
Low
CFM (m3/h)
LONG-LIFE ION DEODORIZATION FILTER
The filter deodorizes by powerfully
Ion
decomposing absorbed odors using the
oxidizing and reducing effects of ions generated by the ultrafine particle ceramic. The filter can be used for approximately
3 years if it is washed with water when dirty to restore its
surface action.
• Wired Remote Control: UTY-RVNUM*
• Wired Remote Control: UTY-RNNUM*
• Simple Remote Control: UTY-RSNUM*
• Dry Contact Wire Kit: UTY-XWZXZ5
• Interface Kit: UTY-XCBXZ2
Quiet
CFM (m3/h)
APPLE-CATECHIN FILTER
Dust, mold spores and micro-organisms
are absorbed onto the filter by static electricity and growth is
inhibited and deactivated. Filter lasts 3-12 months.
* Wall mounted ASU9, 12RLF1 require accessory interface kit #UTY-XCBXZ2 in order to connect these
devices to them.
Fan Speed Stage
Sound
Indoor Sound Level (Clg/Htg): Hi
Medium
Low
Quiet
Outdoor Sound Level Clg/Htg
Electrical
Voltage/Frequency/Phase
Circuit Breaker
Current Rated/Max: Cooling
Current Rated: Heating
Power Use Rated/Max: Cooling
Power Use Rated: Heating
Size & Weight
Net Weight
Dimensions: Height
Ion Deodorization Filter
Width
Depth
Refrigerant
Additional Data
Air Direction: Horizontal
Vertical
Air Filter
Minimum Lineset Length
Ft (m)
Maximum Lineset Length
Ft (m)
Max. Vertical Diff.
Lineset Size
Ft (m)
Inch
18 (8)
10-1/2
268
33-1/16
840
8
203
60 (27)
21-1/4
540
26
660
11-7/16
290
18 (8)
10-1/2
268
33-1/16
840
8
203
80 (36)
21-1/4
540
31
790
11-7/16
290
R410A
R410A
Manual
Automatic
Washable
10 (3)
66 (20.1)
(pre-charge: 49’)
49 (15)
Suc. 3/8
Dis. 1/4
Manual
Automatic
Washable
10 (3)
66 (20.1)
(pre-charge: 49’)
49 (15)
Suc. 3/8
Dis. 1/4
Indoor
ASU9RLF1
Apple-catechin
Filter
Air Filter
lbs. (kg)
Inch
mm
Inch
mm
Inch
mm
Outdoor
AOU12RLFW1
Economy
2
Indoor
ASU12RLF1
Auto
BTUh
BTUh
BTUh
BTUh
Outdoor
AOU9RLFW1
1
Performance
Nominal Cooling
Min.-Max. Cooling
Nominal Heating
Min.-Max. Heating
SEER
HSPF
EER
Cooling Operating Range
Heating Operating Range
Moisture Removal
Fan
Air Circulation: Hi
Medium
Note: Figures are based on 230 Volts.
22
23
SINGLE-ZONE MINI-SPLITS
HFI SYSTEMS 18RLXFW1, 24RLXFW1
HIGH HEAT SYSTEMS 18RLXFWH, 24RLXFWH
18 AND 24,000 BTUh WALL MOUNT HEAT PUMPS
18RLXFW1
24RLXFW1
18RLXFWH
24RLXFWH
18,000
7,000~23,000
21,600
7,000~29,000
20.0
10.5
13.3
-5~115 (-20~46)
-5~75 (-20~24)
5.9 (2.8)
120%
109%
-
22,000
9,900~27,300
25,200
7,500~36,200
19.5
10.6
12.5
-5~115 (-20~46)
-5~75 (-20~24)
6.3 (3.0)
105%
94%
-
18,000
7,000~23,000
21,600
7,000~29,000
20.0
10.4
13.3
-5~115 (-20~46)
-15~75 (-26~24)
5.9 (2.8)
120%
109%
100%
22,000
9,900~27,300
25,200
7,500~36,200
19.5
10.5
12.5
-5~115 (-20~46)
-15~75 (-26~24)
6.3 (3.0)
105%
94%
82%
UP TO 20 SEER
Sensor
5
3rd Party
Cooling
1 Applies when properly registered AND installed by a Fujitsu Elite Contractor in a
residence. See full warranty for details.
2 RLXFW1 systems only.
3 RLXFW1 systems require optional wired remote control.
HIGH PERFORMANCE HEATING CAPACITY
Stay comfortable at low ambient temperatures! The RLXFW1
systems can deliver 100% or more of rated heating capacity
at 5°F (-15°C) and operates down to -5°F (-21°C).
The RLXFWH model can operate down to -15°F. See the full
story on page 14.
6
-5˚F
4
164+ ft
16
Heater
Piping
Daisy
Blue Fin
Weekly
Sleep
4 Available only with optional wired remote control.
5 Available only with optional Interface kit. Operation monitoring and On/Off control only.
6 RLXWFH models only.
180%
18K
160%
24K
140%
RLXFW1
120%
100%
80%
-5°
5°
14°
23°
32°
41°
47°
50°
Outdoor temperature (°F)
OPTIONAL ACCESSORIES
• Wired Remote Control: UTY-RVNUM
• Wired Remote Control: UTY-RNNUM
• Simple Remote Control: UTY-RSNUM
• Dry Contact Wire Kit: UTY-XWZX
RLXFWH
Maximum heating capacity
Based on 70° indoor setpoint
180%
18KH
160%
24KH
140%
120%
100%
80%
-15º -5º
5º
14º
23º
32º
41º
Outdoor temperature (°F)
Based on 70° indoor setpoint
47º
50º
Air Circulation: Hi
CFM (m3/h)
541 (920)
Medium
Low
CFM (m3/h)
CFM (m3/h)
Quiet
CFM (m3/h)
435 (740)
365 (620)
Clg 306 (520)
Htg 318 (540)
4+Auto
Fan Speed Stage
Sound
Indoor Level (Clg/Htg): Hi
Medium
Low
Quiet
Outdoor Level Clg/Htg
Electrical
Voltage/Frequency/Phase
Circuit Breaker
Current Rated/Max: Cooling
Current Rated/Max: Heating
Power Use Rated/Max: Cooling
Power Use Rated/Max: Heating
Size & Weight
Net Weight
Dimensions: Height
Width
Depth
Clg 659 (1,120)
Htg 677 (1,150)
530 (900)
435 (740)
4+Auto
435 (740)
365 (620)
Clg 306 (520)
Htg 318 (540)
4+Auto
365 (620)
Clg 659 (1,120)
Htg 677 (1,150)
530 (900)
435 (740)
541 (920)
365 (620)
4+Auto
dB(A)
dB(A)
dB(A)
dB(A)
dB(A)
43/44
37/37
33/33
28/28
47/50
49/49
42/42
37/37
33/33
54/55
43/44
37/37
33/33
28/28
47/50
49/49
42/42
37/37
33/33
54/55
Amps
Amps
Amps
kW
kW
208-230/60/1
20
6.2/13.5
7.8/14.5
1.35/3.01
1.80/3.23
208-230/60/1
30
7.9/15.0
8.6/15.5
1.76/3.42
2.38/3.53
208-230/60/1
20
6.2/13.5
7.8/14.5
1.35/3.01
1.75/3.23
208-230/60/1
20
7.9/15
8.6/15.5
1.76/3.42
1.94/3.53
31 (14)
134 (61)
12-5/8
32-3/4
320
830
39-1/4
35-3/8
998
900
9
13
228
330
R410A
31 (14)
134 (61)
12-5/8
32-3/4
320
830
39-1/4
35-3/8
998
900
9
13
228
330
R410A
31 (14)
135 (61)
12-5/8
32-3/4
320
830
39-1/4
35-3/8
998
900
9
13
228
330
R410A
31 (14)
135 (61)
12-5/8
32-3/4
320
830
39-1/4
35-3/8
998
900
9
13
228
330
R410A
Automatic
Automatic
Washable
16 (5)
164 (50)
Automatic
Automatic
Washable
16 (5)
164 (50)
Automatic
Automatic
Washable
16 (5)
164 (50)
Automatic
Automatic
Washable
16 (5)
164 (50)
(pre-charge: 66’)
(pre-charge: 66’)
(pre-charge: 65’)
(pre-charge: 65’)
98 (30)
Suc. 5/8
Dis. 3/8
98 (30)
Suc. 5/8
Dis. 3/8
30 (98)
Suc.5/8
Dis.3/8
30 (98)
Suc.5/8
Dis.3/8
lbs. (kg)
Inch
mm
Inch
mm
Inch
mm
Refrigerant
Additional Data
Air Direction: Horizontal
Vertical
Air Filter
Minimum Lineset Length
Ft (m)
Maximum Lineset Length
Ft (m)
Max. Vertical Diff.
Lineset Size
Ft (m)
Inch
* Based on model # capacity class (e.g. 9RLS3Y
based on 9,000 BTUh) @ 70°F indoor setpoint.
Refer to the Design & Technical Manual for more
heating capacity data.
Outdoor
AOU24RLXFWH
Ion
I/O
24 Hour
Quiet Mode
Indoor
ASU24RLF
@
Dry
Restart
Outdoor
AOU18RLXFWH
4
100%
+5°F
4-Way
Indoor
ASU18RLF
Adjust
Outdoor
AOU24RLXFW1
Cold
Changeover
3
Indoor
ASU24RLF
Minimum Heat
Maximum heating capacity
Economy
2
Outdoor
AOU18RLXFW1
Auto
Indoor
ASU18RLF
1
Performance
Nominal Cooling
BTUh
Min.-Max. Cooling
BTUh
Nominal Heating
BTUh
Min.-Max. Heating
BTUh
SEER
HSPF
EER
Cooling Operating Range
°F (°C)
Heating Operating Range
°F (°C)
Moisture Removal
Pt./h (l/h)
0D[+WJRI0RGHO&DSDFLW\DWÝ) Ý&
0D[+WJRI0RGHO&DSDFLW\DWÝ) Ý&
0D[+WJRI0RGHO&DSDFLW\DWÝ) Ý&
Fan
Note: Figures are based on 230 Volts.
24
25
SINGLE-ZONE MINI-SPLITS
Auto
Economy
Weekly
ESP
Minimum Heat
Changeover
100%
Cold
4-Way
Ion
Pump Down
Sensor
Dry
Restart
2
@
+5°F
Adjust
I/O
3
3rd Party
Low Noise
Powerful
Quiet Mode
-5˚F
Cooling
16
Heater
Blue Fin
Daisy
Sleep
2 164+ ft
Piping
1 Applies when properly registered AND installed by a Fujitsu Elite Contractor in a residence. See full warranty for details.
2 Available only with optional wired remote control.
3 Available only with optional Interface kit.
EXTENDED LINESET
Long piping lengths between indoor and outdoor units
provides flexibility and increased applications.
SERVER ROOM MODE
MAX PIPE LENGTH
Max Height Diff.
System 30RLXEH
98 ft.
246 ft. (75m)
(30m)
Server rooms can generate a tremendous amount of heat,
and require cooling 24 hours a day. The strain of such a
heat load is best handled with a redundant cooling system.
Pairing two 30RLXEH systems together in Server Room Mode
offers a unique solution for keeping network servers cool.
Two 30RLXEH systems can be set up to work together in Lead
Lag^ operation:
• Alternative Operation – units alternate operation, so
neither unit is running at the same time.
• Backup Operation – if an error occurs on one unit, the
second unit will turn on.
• Supporting Operation – if the setpoint cannot be reached
with one unit alone, the second unit will come on to satisfy
the demand for cooling.
^ Wired remotes cannot be used when using this feature.
This includes UTY-RNRUZ1, UTY-RVNUM, UTY-RNNUM, UTY-RSNUM.
LOCK OUT FUNCTION
This feature is set by the contractor on behalf of the
Commercial Property Owner to prevent either Cooling or
Heating operation from occurring. This is not a function that
can be set by a tenant, user, or home owner.
HIGH PERFORMANCE HEATING CAPACITY
The RLXEH model can operate down to -15°F. See the full
story on page 14.
ADDITIONAL APPLICATIONS THAT MAY
REQUIRE LOW AMBIENT COOLING:
• Conference/Meeting/Training Rooms
• Social Gathering spots
• Places of Worship
OPTIONAL ACCESSORIES
• Wired Touch Panel Remote Controller:
• Wired Remote Control: UTY-RVNUM^
• Wired Remote Control: UTY-RNNUM^
• Simple Remote Control: UTY-RSNUM^
• Dry Contact Wire Kit: UTY-XWZX
• Interface Kit: UTY-XCSXZ1
• Interface Kit Box: UTZ-GXXB
• Outdoor Unit Input/Output Connector:
HIGH-HEAT
30RLXEH
UP TO 18.7 SEER
Performance
Nominal Cooling
Min.-Max. Cooling
Nominal Heating
Min.-Max. Heating
SEER
HSPF
EER
Cooling Operating Range
Heating Operating Range
Moisture Removal
0D[+WJRI0RGHO&DSDFLW\DWÝ) Ý&
0D[+WJRI0RGHO&DSDFLW\DWÝ) Ý&
0D[+WJRI0RGHO&DSDFLW\DWÝ) Ý&
Fan
Air Circulation: Hi
Medium
Low
Quiet
Fan Speed Stage
Sound
Indoor Sound Level (Clg/Htg): Hi
Medium
Low
Quiet
Outdoor Sound Level Clg/Htg
Electrical
Voltage/Frequency/Phase
Circuit Breaker
Current Rated: Cooling
Current Rated: Heating
Power Use Rated/Max: Cooling
Power Use Rated/Max: Heating
Size & Weight
Net Weight
Dimensions: Height
UTY-RNRUZ1^
Width
Depth
UTY-XWZXZ3
SYSTEM 30RLXEH
BTUh
BTUh
BTUh
BTUh
32,000
8,000~37,500
18.7
11.7
12.5
°F (°C)
°F (°C)
Pt./h (l/h)
-5~115 (-20~46)
-15~75 (-26~24)
9.7 (4.6)
107%
91%
76%
CFM (m3/h)
CFM (m3/h)
CFM (m3/h)
CFM (m3/h)
812 (1,380)
665 (1,130)
536 (910)
418 (710)
4+Auto
dB(A)
dB(A)
dB(A)
dB(A)
dB(A)
50/49
45/44
38/38
32/32
53/54
208-230/60/1
Amps
Amps
Amps
kW
kW
lbs. (kg)
Inch
mm
Inch
mm
Inch
mm
Refrigerant
Additional Data
Air Direction: Horizontal
Vertical
Air Filter
Minimum Lineset Length
Ft (m)
Maximum Lineset Length
Ft (m)
Max. Vertical Diff.
Lineset Size
Ft (m)
Inch
30
10.6
12.0
2.40/3.83
2.74/4.28
40 (18)
205 (93)
13-3/8
50-13/16
340
1,290
45-1/4
35-3/8
1,150
900
11
13
280
330
R410A
*Based on model # capacity class (e.g. 9RLS3Y based on 9,000
BTUh) @ 70°F indoor setpoint. Refer to the Design & Technical
Manual for more heating capacity data.
Note: Figures are based on 230 Volts.
26
30,000
9,900~32,400
Automatic
Automatic
Washable
16 (5)
246 (75)
(pre-charge: 65’)
30 (98)
Suc.5/8
Dis.3/8
Outdoor
AOU30RLXEH
1
The 30RLXEH is specially
engineered for spaces such as
server rooms which require
constant cool temperatures
year round, and rooms that
hold a large number of people
(meeting spaces, classrooms,
conference rooms).
Indoor
ASU30RLE
30,000 BTUh WALL MOUNT HEAT PUMP
27
SINGLE-ZONE MINI-SPLITS
SYSTEMS 9RL2, 12RL2
9 AND 12,000 BTUh, 115V, WALL MOUNT HEAT PUMPS
16.0 SEER
Changeover
Adjust
Up/Down
Restart
Dry
Powerful
Quiet Mode
Sleep
Cold
1 Applies when properly registered AND installed by a Fujitsu Elite Contractor in residence. See full warranty for details.
FUNCTION
APPLICATIONS
Stylish, slim and elegant, these popular wall mounted units
are designed for single rooms. Indoor units have a clean,
aesthetic design and are small but mighty and shorter in
length than competing units, helping them blend into any
room.
This category of equipment is ideal for smaller spaces where
spot cooling or heating is required. Residential applications
including sunrooms and additions are made easier with
these 115 volt heat pumps. Do you have a warm or cool spot
in your home? Fujitsu mini-splits can provide extra cooling or
heating capacity for those hard to cool areas. Commercially,
their small size makes them ideal for small offices, providing
individual temperature control.
EASY MAINTENANCE
Front panel is easily removed for cleaning.
Dimensions: Height
Width
Depth
12,000
3,100~12,500
14,000
3,100~16,000
16.0
9.0
10.0
15~115 (-10~46)
15~75 (-10~24)
3.8 (1.8)
CFM (m3/h)
CFM (m3/h)
CFM (m3/h)
CFM (m3/h)
436 (740)
353 (600)
265 (450)
191 (325)
4 + Auto
436 (740)
353 (600)
265 (450)
191 (325)
4 + Auto
dB(A)
dB(A)
dB(A)
dB(A)
dB(A)
43/43
38/38
33/33
23/23
47/48
43/43
38/38
33/33
23/23
51/51
Amps
Amps
Amps
kW
kW
115/60/1
15
7.5
7.0
0.83
0.77
115/60/1
20
10.9
11.0
1.20
1.21
°F (°C)
°F (°C)
Pt./h (l/h)
lbs. (kg)
Inch
mm
Inch
mm
Inch
mm
Ft (m)
Maximum Lineset Length
Ft (m)
Max. Vertical Diff.
Lineset Diameter
Ft (m)
Inch
64 (29)
21-1/4
540
26
660
11-11/32
290
16 (7)
10-5/16
262
32-9/32
820
8-1/8
206
69 (31)
21-1/4
540
26
660
11-11/32
290
R410A
R410A
Manual
Automatic
Washable
10 (3)
66 (20)
(pre-charge: 49’)
49 (15)
Suc. 3/8
Dis. 1/4
Manual
Automatic
Washable
10 (3)
66 (20)
(pre-charge: 49’)
49 (15)
Suc. 3/8
Dis. 1/4
Indoor
ASU9RL2
Refrigerant
Additional Data
Air Direction: Horizontal
Vertical
Air Filter
Minimum Lineset Length
16 (7)
10-5/16
262
32-9/32
820
8-1/8
206
Outdoor
AOU12RL2
Economy
9,000
1,700~10,700
10,000
1,700~12,000
16.0
9.0
10.8
15~115 (-10~46)
15~75 (-10~24)
2.7 (1.3)
BTUh
BTUh
BTUh
BTUh
Indoor
ASU12RL2
Auto
12RL2
Outdoor
AOU9RL2
1
Performance
Nominal Cooling
Min.-Max. Cooling
Nominal Heating
Min.-Max. Heating
SEER
HSPF
EER
Cooling Operating Range
Heating Operating Range
Moisture Removal
Fan
Air Circulation: Hi
Medium
Low
Quiet
Fan Speed Stage
Sound
Indoor Sound Level (Clg/Htg): Hi
Medium
Low
Quiet
Outdoor Sound Level Clg/Htg
Electrical
Voltage/Frequency/Phase
Circuit Breaker
Current Rated: Cooling
Current Rated: Heating
Power Use Rated: Cooling
Power Use Rated: Heating
Size & Weight
Net Weight
9RL2
Note: Figures are based on 115 Volts.
28
29
SINGLE-ZONE MINI-SPLITS
18, 24, 30, 36,000 BTUh WALL MOUNT HEAT PUMPS
SYSTEMS 18RLB, 24RLB, 30RLXB, 36RLXB
18RLB
24RLB
UP TO 19.0 SEER
Blue Fin
Daisy
Sleep
Weekly
Cold
2 164+ ft 4
Piping
1 Applies when properly registered AND installed by a Fujitsu Elite Contractor in a residence. See full warranty for details.
2 Available only with optional wired remote control.
3 Available only with optional Interface kit.
4 RLXB models only.
FUNCTION
LOCK OUT FUNCTION
Stylish, slim and elegant, these wall mounted ductless
heat pumps are designed for single rooms. Ideal for spaces
requiring additional capacity but are limited on space. With
more efficient zone control, ductless mini-splits are perfect
for renovations, restorations, conversions, and add-ons.
This feature is set by the contractor on behalf of the
Commercial Property Owner to prevent either Cooling or
Heating operation from occurring. This is not a function that
can be set by a tenant, user, or home owner.
OPTIONAL ACCESSORIES
• Wired Remote Control: UTY-RVNUM
• Wired Remote Control: UTY-RNNUM
• Simple Remote Control: UTY-RSNUM
• Dry Contact Wire Kit: UTY-XWZX
33,000
9,900~34,100
18,000
24,000
30,000
34,000
7,000~20,000
7,500~27,000
8,000~33,000
10,200~35,000
19.0
10.6
12.5
18.0
10.6
10.0
16.5
9.0
9.5
15.5
9.0
8.5
°F (°C)
°F (°C)
Pt./h (l/h)
14~115 (-10~46)
14~115 (-10~46)
14~115 (-10~46)
14~115 (-10~46)
5~75 (-15~24)
5~75 (-15~24)
5~75 (-15~24)
5~75 (-15~24)
4.0 (1.9)
6.3 (3.0)
9.7 (4.6)
10.1 (4.8)
CFM (m3/h)
CFM (m3/h)
CFM (m3/h)
CFM (m3/h)
542 (920)
439 (740)
365 (620)
306 (520)
659 (1,120) Clg
647 (1,100) Htg
659 (1,120) Clg
677 (1,150) Htg
530 (900)
436 (740)
365 (620)
530 (900)
436 (740)
365 (620)
695 (1,180)
530 (900)
436 (740)
365 (620)
4+Auto
4+Auto
4+Auto
4+Auto
42/43
35/36
31/33
26/28
51/50
47/47
41/42
35/36
31/33
54/55
47/49
42/42
37/37
32/33
52/55
50/50
42/42
37/37
32/33
52/55
208-230/60/1
208-230/60/1
208-230/60/1
208-230/60/1
15
6.4/8.3
5.8/11.8
1.44/1.89
1.29/2.69
20
10.5/11.8
8.5/13.8
2.40/2.69
1.93/3.14
30
13.8/16.8
12.3/18.8
3.16/3.83
2.80/4.28
30
17.0/18.0
14.8/18.8
3.88/4.10
3.39/4.28
Fan
Air Circulation: Hi
Medium
Low
Quiet
Fan Speed Stage
Sound
Indoor Sound Level (Clg/Htg): Hi
Medium
Low
Quiet
Outdoor Sound Level Clg/Htg
Electrical
Voltage/Frequency/Phase
Circuit Breaker
Current Rated/Max: Cooling
Current Rated/Max: Heating
Power Use Rated: Cooling
Power Use Rated: Heating
Size & Weight
Net Weight
Dimensions: Height
Width
Depth
dB(A)
dB(A)
dB(A)
dB(A)
dB(A)
Amps
Amps
Amps
kW
kW
lbs. (kg)
Inch
mm
Inch
mm
Inch
mm
Refrigerant
Additional Data
Air Direction: Horizontal
Vertical
Air Filter
Minimum Piping Length
Ft (m)
Maximum Piping Length
Ft (m)
Maximum Vertical Differential
Lineset Size
Ft (m)
Inch
31 (14)
86 (39)
31 (14)
86 (39)
31 (14)
134 (61)
31 (14)
134 (61)
12-5/8
24-7/16
12-5/8
24-7/16
12-5/8
32-11/16
12-5/8
32-11/16
320
620
320
620
320
830
320
830
39-5/16
31-1/8
39-5/16
31-1/8
39-5/16
35-7/16
39-5/16
35-7/16
998
790
998
790
998
900
998
900
9
11-7/16
9
11-7/16
9
13
9
13
228
290
228
290
228
330
228
330
R410A
R410A
R410A
R410A
Automatic
Automatic
Washable
10 (3)
Automatic
Automatic
Washable
10 (3)
Automatic
Automatic
Washable
16 (5)
Automatic
Automatic
Washable
16 (5)
66 (20)
66 (20)
165 (50)
165 (50)
(pre-charge: 49’)
(pre-charge: 49’)
(pre-charge: 66’)
(pre-charge: 66’)
49 (15)
49 (15)
98 (30)
Suc.1/2
Dis.1/4
Suc.1/2
Dis.1/4
Suc.5/8
98 (30)
Dis.3/8
Suc.5/8
Dis.3/8
Outdoor
AOU36RLXB
16
Quiet Mode
30,000
9,900~32,400
Indoor
ASU36RLXB
4
Dry
24,000
3,100~25,000
Outdoor
AOU30RLXB
3rd Party
3
Restart
18,000
Indoor
ASU30RLXB
Sensor
I/O
4-Way
36RLXB
3,100~19,000
Outdoor
AOU24RLB
2
Adjust
Changeover
Minimum Heat
2
BTUh
BTUh
BTUh
BTUh
Indoor
ASU24RLB
Auto
Economy
Ion
Performance
Nominal Cooling
Min.-Max. Cooling
Nominal Heating
Min.-Max. Heating
SEER
HSPF
EER
Cooling Operating Range
Heating Operating Range
Moisture Removal
Outdoor
AOU18RLB
1
AOU30RLXB
AOU36RLXB
Indoor
ASU18RLB
AOU18RLB
AOU24RLB
30RLXB
Note: Figures are based on 230 Volts.
30
31
SINGLE-ZONE MINI-SPLITS
9, 12, 15,000 BTUh FLOOR MOUNT HEAT PUMPS
HFI SYSTEMS
9RLFF, 12RLFF, 15RLFF
HIGH HEAT SYSTEMS 9RLFFH, 12RLFFH, 15RLFFH
9RLFF
12RLFF
15RFF
9RLFFH
12RLFFH
15RLFFH
UP TO 26 SEER
Heater
Daisy
IDEAL RADIATOR REPLACEMENT
Weekly
1 Applies when properly registered AND installed by a Fujitsu Elite Contractor
in a residence. See full warranty for details.
2 Available with optional wired remote control.
3 RLFFH models only.
BASE PAN HEATER (RLFFH MODELS)
RLFF models can operate down to -5°F. RLFFH models can
operate down to -15°F. See the full
story on page 14.
OPTIONAL ACCESSORIES
At less than 24” high and 30” wide, floor mount models fit
easily under a standard window and can replace a radiator
twice its size while producing more capacity.
TWO FANS AND WIDE AIRFLOW
• Wired Remote Control: UTY-RVNUM
• Wired Remote Co ntroller: UTY-RNNUM
• Simple Remote Control: UTY-RSNUM
• Dry Contact Wire Kit: UTY-XWZXZ5
Cooling
Having both upper and lower
airflow quickly warms or cools the
entire room. Floor mount can be
set in “Upward Airflow Only” when
occupants wish not to have feet
warmed or cooled.
Fig. 1
1. Upon startup, both top and
bottom louvers open.
2. As the room temperature nears
the setpoint, only the top louver
stays open to help prevent cold air
from falling.
Fig. 2
Heating
Fig. 2
1. Upon startup, both top and
bottom louvers open.
2. Closer to setpoint, only the top
louver stays open to help prevent
cold drafts from windows.
FLEXIBLE AND EASY INSTALLATION
Beneath
standard window
Standard
concave portion
279/16”
Wall
Half concealed*
Min.
231/4”
Min.
279/16”
Max. 5-7/8”
29-1/8”
7-7/8”
Min. 28-3/4”
Max. 3-1/8”
*Field supplied insulation required
32
20.3
22.7
11.3
13.1
20.3
12.5
26.0
12.4
16.0
14~115 (-10~46)
14~115 (-10~46)
14~115 (-10~46)
14~115 (-10~46)
14~115 (-10~46)
14~115 (-10~46)
-5~75 (-21~24)
-5~75 (-21~24)
-5~75 (-21~24)
-15~75 (-26~24)
-15~75 (-26~24)
-15~75 (-26~24)
2.75 (1.3)
3.8 (1.8)
4.44 (2.1)
2.75 (1.3)
3.8 (1.8)
4.44 (2.1)
149%
130%
--
125%
111%
--
118%
107%
--
149%
130%
115%
125%
111%
100%
118%
107%
96%
CFM (m3/h)
CFM (m3/h)
CFM (m3/h)
CFM (m3/h)
335 (570)
271 (460)
212 (360)
159 (270)
4+Auto
335 (570)
271 (460)
212 (360)
159 (270)
4+Auto
383 (650)
306 (520)
235 (400)
159 (270)
4+Auto
335 (570)
271 (460)
212 (360)
159 (270)
4+Auto
335 (570)
271 (460)
212 (360)
159 (270)
4+Auto
383 (650)
306 (520)
235 (400)
159 (270)
4+Auto
dB(A)
dB(A)
dB(A)
dB(A)
dB(A)
40/40
35/35
29/29
23/23
50/50
40/40
35/35
29/29
23/23
52/52
44/43
38/37
31/29
23/23
54/54
40/40
35/35
29/29
23/23
50/50
40/40
35/35
29/29
23/23
52/52
44/43
38/37
31/29
23/23
54/54
Amps
Amps
Amps
208-230/60/1
15
2.9
4.1
208-230/60/1
15
4.2
6.7
208-230/60/1
20
5.1
7.0
208-230/60/1
15
2.9
4.1
208-230/60/1
15
4.2
6.7
208-230/60/1
20
5.1
7.0
Power Use Rated: Cooling
kW
.56
.97
1.13
.56
.97
1.13
Power Use Rated: Heating
Size & Weight
Net Weight
kW
.88
1.44
1.58
.88
1.44
1.58
°F (°C)
°F (°C)
Pt./h (l/h)
0D[+WJRI0RGHO&DSDFLW\DWÝ) Ý&
0D[+WJRI0RGHO&DSDFLW\DWÝ) Ý&
0D[+WJRI0RGHO&DSDFLW\DWÝ) Ý&
Fan
Air Circulation: Hi
Medium
Low
Quiet
Fan Speed Stage
Sound
Indoor Level (Clg/Htg): Hi
Medium
Low
Quiet
Outdoor Level Clg/Htg
Electrical
Voltage/Frequency/Phase
Circuit Breaker
Current Rated: Cooling
Current Rated: Heating
Width
Depth
lbs. (kg)
Inch
mm
Inch
mm
Inch
mm
Refrigerant
Min. 37”
235/8”
22.7
11.6
13.1
Dimensions: Height
Window
Fig. 1
26.0
12.6
16.0
Additional Data
Air Direction: Horizontal
Vertical
Air Filter
Minimum Lineset Length
Ft (m)
Maximum Lineset Length
Ft (m)
Max. Vertical Differential
Lineset Size
Ft (m)
Inch
* Based on model # capacity class (e.g. 9RLS3Y
based on 9,000 BTUh) @ 70°F indoor setpoint.
Refer to the Design & Technical Manual for
more heating capacity data.
11.2
11.0
12.5
31 (14)
84 (38)
31 (14)
84 (38)
31 (14)
86 (39)
31 (14)
86 (39)
31 (14)
86 (39)
31 (14)
88 (40)
23-5/8
24-7/16
23-5/8
24-7/16
23-5/8
24-7/16
23-5/8
24-7/16
23-5/8
24-7/16
23-5/8
24-7/16
600
620
600
620
600
620
600
620
600
620
600
620
29-1/8
31-1/8
29-1/8
31-1/8
29-1/8
31-1/8
29-1/8
31-1/8
29-1/8
31-1/8
29-1/8
31-1/8
740
790
740
790
740
790
740
790
740
790
740
790
7-7/8
11-7/16
7-7/8
11-7/16
7-7/8
11-7/16
7-7/8
11-7/16
7-7/8
11-7/16
7-7/8
11-7/16
200
290
200
290
200
290
200
290
200
290
200
290
R410A
R410A
R410A
R410A
R410A
R410A
Manual
Auto
Washable
10 (3)
66 (20)
Manual
Auto
Washable
10 (3)
66 (20)
Manual
Auto
Washable
10 (3)
66 (20)
Manual
Auto
Washable
10 (3)
66 (20)
Manual
Auto
Washable
10 (3)
66 (20)
Manual
Auto
Washable
10 (3)
66 (20)
(pre-charge: 49’)
(pre-charge: 49’)
(pre-charge: 49’)
(pre-charge: 49’)
(pre-charge: 49’)
(pre-charge: 49’)
49 (15)
49 (15)
49 (15)
49 (15)
49 (15)
49 (15)
Suc. 3/8
Dis. 1/4
Suc. 3/8
Dis. 1/4
Suc. 1/2
Dis. 1/4
Suc. 3/8
Dis. 1/4
Suc. 3/8
Dis. 1/4
Suc. 1/2
Dis. 1/4
Outdoor
AOU15RLFFH
Sensor
Sleep
Indoor
AGU15RLF
Ion
24 Hour
Outdoor
AOU12RLFFH
2
16
Quiet Mode
Indoor
AGU12RLF
3
Powerful
Outdoor
AOU9RLFFH
@
Dry
Restart
Indoor
AGU9RLF
2
100%
+5°F
Up/Down
14,200
3,100~17,700
18,000
3,100~20,800
Outdoor
AOU15RLFF
Adjust
12,000
3,100~14,300
16,000
3,100~19,500
Indoor
AGU15RLF
Cold
Changeover
9,000
3,100~13,000
12,000
3,100~18,800
Outdoor
AOU12RLFF
Minimum Heat
14,200
3,100~17,700
18,000
3,100~23,900
Indoor
AGU12RLF
Economy
2
12,000
3,100~14,300
16,000
3,100~22,100
Outdoor
AOU9RLFF
Auto
9,000
3,100~13,000
12,000
3,100~18,800
BTUh
BTUh
BTUh
BTUh
Indoor
AGU9RLF
1
Performance
Nominal Cooling
Min.-Max. Cooling
Nominal Heating
Min.-Max. Heating
SEER
HSPF
EER
Cooling Operating Range
Heating Operating Range
Moisture Removal
Note: Figures are based on 230 Volts.
33
SINGLE-ZONE MINI-SPLITS
9, 12, 18,000 BTUh COMPACT CASSETTE HEAT PUMPS
Compact Cassette Grille UTG-CCGF shown is sold separately
and must be ordered with each compact cassette.
Weekly
Cold
+5°F
Daisy
1 Applies when properly registered AND installed by a Fujitsu Elite Contractor in a residence. See full warranty for details.
2 Available only with optional wireless remote control.
3 Requires Fujitsu’s Optional Fresh Air Kit part #UTZ-VXAA. Allows for a 4-inch flex duct connection. Requires a field supplied duct booster fan capable of 60 CFM at .2”W.C. or
90 CFM at .4”W.C. For fan static pressure requirements, see installation manual. Add hood, filter and duct losses for fan total static pressure requirements. Will add 4” to the
height of the indoor unit.
4 Available only with optional Interface kit. Operation monitoring and On/Off control only.
Air Circulation: Hi
FUNCTION
Medium
Compact cassettes provide comfort cooling or heating for
small room applications. Features include high efficiency
up to 24.0 SEER, heating at low temperatures down to -5°F,
compact design, quiet operation, a standard wired remote
control, and the ability to bring in fresh air through the
optional Fresh Air Kit.
Low
Quiet
EASY INSTALLATION
Fits into a standard ceiling tile*.
22.5”
22.5”
*Dimensions of
outer grille are
27-9/16” x 279/16” and may
overlap adjacent
tiles.
QUIET OPERATION
Optimization of wing form (laminar wing design) and
number of wings (7 blades) enables as low as 27 dB.
Fan Speed Stage
Sound
Indoor Sound Level (Clg/Htg): Hi
Medium
Low
Quiet
Outdoor Sound Level Clg/Htg
Electrical
Voltage/Frequency/Phase
Circuit Breaker
Current Rated: Cooling
Current Rated: Heating
Power Use Rated/Max: Cooling
Power Use Rated/Max: Heating
Size & Weight
Net Weight
Dimensions: Height
Width
2-STAGE TURBO FAN
Depth
Air distribution is evenly spread across the heat exchanger
by the 2 stage turbo fan which produces two separate airflow
streams.
Heat exchange
efficiency:
Increased 20%
359 (610) Clg or Htg
288 (490) Clg or Htg
312 (530) Clg or Htg
259 (440) Clg or Htg
277 (470) Clg or Htg
230 (390) Clg or Htg
241 (410) Clg or Htg
4+auto
4+auto
400 (680) Clg
471 (800) Htg
341 (580) Clg
400 (680) Htg
288 (490) Clg
341 (580) Htg
241 (410) Clg
265 (450) Htg
4+auto
dB(A)
dB(A)
dB(A)
dB(A)
dB(A)
33/34
32/32
29/29
28/27
48/49
37/37
33/33
31/31
28/28
49/50
40/44
36/40
32/36
28/30
54/55
Amps
Amps
Amps
kW
kW
208-230/60/1
15
3.0
4.1
0.62/1.40
0.89/1.80
208-230/60/1
15
4.4
6.7
0.94/1.45
1.44/2.00
208-230/60/1
20
7.1
7.7
1.61/2.15
1.76/2.60
CFM
(m3/h)
CFM
(m3/h)
CFM
(m3/h)
CFM
(m3/h)
lbs. (kg)
Inch
mm
Inch
mm
Inch
mm
33 (15)
9-11/16
245
22-7/16
570
22-7/16
570
Refrigerant
Additional Data
Air Direction: Vertical
Air Filter
Minimum Lineset Length
1-stage
2-stage
318 (540) Clg or Htg
°F (°C)
°F (°C)
Pt./h (l/h)
OPTIONAL ACCESSORIES
• Wired Remote Control: UTY-RVNUM
• Wireless remote UTY-LNHU
• Fresh Air Kit3 UTZ-VXAA
Mixes room air which then passes through the heat exchanger.
Ft (m)
Max. Vertical Diff.
Lineset Size
Ft (m)
Inch
33 (15)
9-11/16
245
22-7/16
570
22-7/16
570
84 (38)
1-15/16 24-1/2
49
620
27-9/16 31-3/32
700
790
27-9/16 11-11/32
700
290
33 (15)
9-11/16
245
22-7/16
570
22-7/16
570
86 (39)
1-15/16 24-1/2
49
620
27-9/16 31-3/32
700
790
27-9/16 11-11/32
700
290
R410A
R410A
R410A
Automatic
Washable
10 (3)
66 (20)
Automatic
Washable
10 (3)
66 (20)
Automatic
Washable
10 (3)
66 (20)
(pre-charge: 49’)
(pre-charge: 49’)
(pre-charge: 49’)
49 (15)
49 (15)
Ft (m)
Maximum Lineset Length
84 (38)
1-15/16 24-1/2
49
620
27-9/16 31-3/32
790
700
27-9/16 11-11/32
700
290
suc 3/8
dis 1/4
suc 3/8
49 (15)
dis 1/4
suc 1/2
dis 1/4
Outdoor
AOU18RLF
Quiet Mode
16
Pump
18,000
3,100~20,100
21,600
3,100~25,600
20.1
11.5
11.2
14~115 (-10~46)
-5~75 (-21~24)
4.6 (2.2)
Grille
UTG-CCGF
Fresh
4
3rd Party
12,000
3,100~13,600
16,000
3,100~19,400
21.9
12.2
12.8
14~115 (-10~46)
-5~75 (-21~24)
2.5 (1.2)
Indoor
AUU18RLF
Sensor
Dry
9,000
3,100~12,000
12,000
3,100~18,000
24.0
13.0
14.5
14~115 (-10~46)
-5~75 (-21~24)
1.3 (.06)
BTUh
BTUh
BTUh
BTUh
Outdoor
AOU12RLFC
Ceiling
I/O
Restart
@
Performance
Nominal Cooling
Min.-Max. Cooling
Nominal Heating
Min.-Max. Heating
SEER
HSPF
EER
Cooling Operating Range
Heating Operating Range
Moisture Removal
Fan
Grille
UTG-CCGF
Up/Down
100%
Indoor
AUU12RLF
Adjust
Changeover
Minimum Heat
3
Outdoor
AOU9RLFC
Economy
18RLFCC
UP TO 24.0 SEER
Auto
12RLFCC
Grille
UTG-CCGF
2
9RLFCC, 12RLFCC, 18RLFCC
9RLFCC
Indoor
AUU9RLF
1
HFI SYSTEMS
Note: Figures are based on 230 Volts.
34
35
SINGLE-ZONE MINI-SPLITS
9, 12, 18,000 BTUh SLIM DUCT HEAT PUMPS
HFI
SYSTEMS 9RLFCD, 12RLFCD, 18RLFCD
9RLFCD
12RLFCD
18RLFCD
°F (°C)
°F (°C)
Pt./h (l/h)
9,000
3,100~12,000
12,000
3,100~18,000
21.5
12.2
14.5
14~115 (-10~46)
-5~75 (-21~24)
1.5 (.07)
12,000
3,100~13,600
16,000
3,100~19,400
20.0
11.5
12.8
14~115 (-10~46)
-5~75 (-21~24)
2.7 (1.3)
18,000
3,100~20,100
21,600
3,100~25,600
19.7
11.3
12.0
14~115 (-10~46)
-5~75 (-21~24)
4.2 (2.0)
CFM (m3/h)
CFM (m3/h)
CFM (m3/h)
CFM (m3/h)
353 (600)
324 (550)
294 (500)
265 (450)
383 (650)
353 (600)
324 (550)
283 (480)
554 (940)
518 (880)
483 (820)
442 (750)
4+auto
4+auto
4+auto
dB(A)
28/28
29/29
32/32
dB(A)
dB(A)
dB(A)
dB(A)
27/26
26/25
25/24
48/49
28/28
27/27
26/24
49/50
30/30
29/29
27/27
54/55
208-230/60/1
208-230/60/1
208-230/60/1
15
3.0
3.9
0.62/1.40
0.85/1.80
15
4.4
6.0
0.94/1.45
1.30/2.00
20
6.6
7.3
1.50/2.15
1.67/2.60
UP TO 21.5 SEER
Performance
+5°F
3rd Party
Sensor
1 Applies when properly registered AND installed by a Fujitsu Elite Contractor in a residence. See full warranty for details.
2 Available only with optional wireless remote control.
3 Available only with optional Interface kit. Operation monitoring and On/Off control only.
FUNCTION
FLEXIBLE INSTALLATION
Slim ducts provide cooling or heating for small room
applications such as offices, restaurants, convenience
stores, motels, dorms, in retrofit and new construction. Long
maximum combined piping length of 66’ and 49’ in height
allow for versatile installations. Either horizontal or vertical
flexibility and low height enables compact soffit or cabinet
installation.
Unit can be placed horizontally or vertically. However,
internal drain pump will not operate when the unit is
mounted in a vertical configuration.
Fan Speed Stage
Built-in drain pump allows for installation of slim duct unit in
smaller spaces than traditional units.
Sound
Indoor Sound Level (Clg/Htg):
Hi
Medium
Low
Quiet
Outdoor Sound Level Clg/Htg
Electrical
Traditional
Voltage/Frequency/Phase
SLIM DUCT
Slim Duct
13”
RETURN AIR-INTAKE CHOICES
Bottom
OPTIONAL ACCESSORIES
Back
• Wired Remote Control: UTY-RVNUM
• Wireless Remote and Receiver UTY-LRHUM
Dimensions: Height
• Auto Louver Grille Kit UTD-GXSA-W(for ARU7/9/12)
UTD-GXSB-W (for ARU18)
Width
FIELD SUPPLIED FILTERS USED WITH SLIM DUCT UNITS
Although Slim Duct units come with factory filters, when return ductwork is
used field supplied filters are more practical to use. They can be installed at
the unit or for more convenient servicing, in filter grilles. See the guidelines
to the right to determine filter sizes.
The chart includes CFM, external static pressure capability and a typical filter
size for each model. Filters are sized to keep velocities and static pressure
loss low. This will ensure sufficient static pressure is available for ductwork,
fittings and supply and return grilles.
Alternative filter sizes with equivalent face areas can be used. After
deducting filter loss, available static pressure
values are shown.
A fiberglass filter is shown in blue to
the left. A MERV pleated filter is shown
in white.
36
Circuit Breaker
Current Rated: Cooling
Current Rated: Heating
Power Use Rated/Max: Cooling
Power Use Rated/Max: Heating
Size & Weight
Net Weight
Drain 9.4”
Pump
ARU
9RLF
CFM
Typical Filter Size
Velocity, FPM
Unit External SP, in.
W.C.
ARU
12RLF
ARU
18RLF
353
383
547
12 x 20
12 x 20
14 x 25
212
230
228
0.36
0.36
0.36
1” Fiberglass Filter
Depth
Amps
Amps
Amps
kW
kW
lbs. (kg)
Inch
mm
27-9/16
mm
700
2413/32
620
Inch
mm
Refrigerant
Air Filter
Minimum Lineset Length
Ft (m)
0.05
0.04
Maximum Lineset Length
Ft (m)
Available Static Pressure
0.32
0.31
0.32
Max. Vertical Diff.
Ft (m)
Available Static Pressure
SP Loss, in. W.C.
Available Static Pressure
0.12
0.14
0.14
0.24
0.22
0.22
2” MERV 8 Pleated Filter
0.07
0.08
0.08
0.29
0.28
0.28
84 (38) 50 (23)
84 (38) 41 (19)
6
24-1/2
151
2519/32
650
152
620
3/4
3/4 Flat
19
22
559
19 Flat
7-25/32 5-15/16
198
31-3/32 27-9/16
790
1111/32
290
700
2413/32
620
6
24-1/2
151
2519/32
650
152
620
3/4
3/4 Flat
19
22
559
19 Flat
198
31-3/32 35-7/16
790
1111/32
290
86 (39)
7-25/32 5-15/16
900
2413/32
620
6
24-1/2
151
3315/32
850
152
620
30
31-3/32
762
3/4
3/4 Flat
790
1111/32
290
19
19 Flat
R410A
R410A
R410A
0 ~ 0.36
0 ~ 0.36
0 ~ 0.36
Washable
Washable
Washable
10 (3)
10 (3)
10 (3)
66 (20)
66 (20)
66 (20)
(pre-charge: 49’)
(pre-charge: 49’)
(pre-charge: 49’)
49 (15)
49 (15)
Additional Data
Static Pressure in. W. C.
0.04
SP Loss, in. W.C.
198
Inch
SP Loss, in. W.C.
1” MERV 8 Pleated Filter
41 (19)
7-25/32 5-15/16
Lineset Size
Inch
suc 3/8
dis 1/4 suc 3/8
49 (15)
dis 1/4
suc
1/2
dis 1/4
Outdoor
AOU18RLF
Cold
RETURN
DUCT
Weekly
SUPPLY DUCT
FLANGE
Quiet Mode
Indoor
ARU18RLF
Fresh
Outdoor
AOU12RLFC
Dry
RETURN
DUCT
Restart
3
SUPPLY DUCT
FLANGE
Daisy
Adjust
I/O
@
Indoor
ARU12RLF
Pump
Changeover
100%
Outdoor
AOU9RLFC
16
Minimum Heat
RETURN
DUCT
Economy
Auto
SUPPLY DUCT
FLANGE
2
BTUh
BTUh
BTUh
BTUh
Indoor
ARU9RLF
1
Nominal Cooling
Min.-Max. Cooling
Nominal Heating
Min.-Max. Heating
SEER
HSPF
EER
Cooling Operating Range
Heating Operating Range
Moisture Removal
Fan
Air Circulation: Hi
Medium
Low
Quiet
Note: Figures are based on 230 Volts.
37
SINGLE-ZONE MINI-SPLITS
SYSTEMS 18RULX, 24RULX, 36RSLX
18, 24, 36,000 BTUh CEILING & UNIVERSAL HEAT PUMPS
UP TO 16 SEER
Daisy
Restart
Dry
Fresh
24 Hour
Sleep
Weekly
Cold
Ceiling
164+ ft
Piping
1 Available only with optional wired remote control.
2 Fresh air knockout available. Fresh air fan and ductwork field supplied. See Design and Technical Manual for details.
APPLICATIONS
FUNCTION
The universal floor/ceiling mount 18RULX and 24RULX are
ideal for a house of worship to mount beneath stained glass
windows. Lower in height than the pews, they do not disturb
the aesthetics of the space. With long piping lengths of 165’
the outdoor units can also be placed remotely out of sight.
Another popular application for this model is in hallways
where wall space is limited. The 36RSLX is popular where
fresh air intake and high capacity is required like a restaurant
or bar. They are also often suspended from threaded rod and
used in multiple to condition large warehouse spaces.
The 18RULX and the 24RULX are universal mount. They can
mount low on the wall or transverse mount them on the
ceiling. The 36RSLX can only be mounted on the ceiling, can
take in fresh air and can throw air farther.
OPTIONAL ACCESSORIES
• Wired Remote Control UTY-RNBYU*
• Weekly Timer
• Full Function Wired Remote
• Child Lock Capable
*Requires dip switch change on indoor unit.
• Condensate Pump UTR-DPB24T
• OEM design plug and play
• Rated for 11.8” of vertical lift.
• Available only for System 36RSLX.
°F (°C)
°F (°C)
Pt./h (l/h)
CFM (m3/h)
459 (780)
518 (880)
1089 (1850)
Medium
CFM (m3/h)
383 (650)
436 (740)
977 (1660)
Low
CFM (m3/h)
324 (550)
371 (630)
842 (1430)
Quiet
CFM (m3/h)
3 + Auto
3 + Auto
3 + Auto
Fan Speed Stage
Sound
Indoor Sound Level (Clg/Htg): Hi
dB(A)
43/43 (Clg/Htg)
47/47 (Clg/Htg)
48/48 (Clg/Htg)
Medium
dB(A)
39/39 (Clg/Htg)
43/43 (Clg/Htg)
45/43 (Clg/Htg)
Low
dB(A)
35/35 (Clg/Htg)
38/38 (Clg/Htg)
41/39 (Clg/Htg)
51/53
53/55
54/55
208-230/60/1
Quiet
dB(A)
Outdoor Sound Level Clg/Htg
Electrical
Voltage/Frequency/Phase
dB(A)
208-230/60/1
208-230/60/1
Circuit Breaker
Amps
20
20
30
Current Rated/Max: Cooling
Amps
7.1/12.5
9.8/12.5
18.3/18.8
Current Rated/Max: Heating
Amps
9.8/12.5
10.2/12.5
15.3/18.8
Power Use Rated/Max: Cooling
kW
1.63/2.88
2.25/2.88
4.22/4.35
Power Use Rated/Max: Heating
Size & Weight
Net Weight
kW
2.25/2.88
2.35/2.88
3.50/4.35
Dimensions: Height
Width
Depth
Refrigerant
Additional Data
Air Direction: Horizontal
Vertical
Air Filter
Front Grille
Minimum Lineset Length
lbs. (kg)
62 (28)
141 (64)
62 (28)
141 (64)
106 (48)
141 (64)
Inch
7-7/8
32-3/4
7-7/8
32-3/4
9-1/2
32-3/4
mm
199
830
199
830
240
830
Inch
39-1/8
35-1/2
39-1/8
35-1/2
65-1/2
35-1/2
mm
990
900
990
900
1660
900
Inch
25-7/8
13
25-7/8
13
27-5/8
13
mm
655
330
655
330
700
330
Ft (m)
Ft (m)
Ft (m)
Inch
R410A
R410A
Automatic
Automatic
Washable
Permanent
16 (5)
165 (50)
(pre-charge: 49’)
66 (20)
Suc.1/2
Dis. 1/4
Automatic
Automatic
Washable
Permanent
16 (5)
165 (50)
(pre-charge: 49’)
66 (20)
Suc.5/8
Dis. 3/8
Automatic
Automatic
Washable
Permanent
16 (5)
165 (50)
(pre-charge: 49’)
98 (30)
Suc.5/8
Dis. 3/8
Indoor
ABU18RULX
Maximum Lineset Length
Max. Vertical Diff.
Lineset Size
R410A
Outdoor
AOU36RLX
Cooling
16
4-Way
34,100
8,500~36,000
36,500
9,200~42,700
14.0
8.5
8.1
0~115 (-18~46)
14~75 (-10~24)
7.4 (3.5)
17,800
5,000~21,600
21,500
5,000~25,600
16.0
8.5
10.9
0~115 (-18~46)
14~75 (-10~24)
5.3 (2.5)
BTUh
BTUh
BTUh
BTUh
Indoor
ABU36RSLX
Sensor
0˚F
Adjust
1
22,200
5,000~27,300
24,000
5,000~29,000
15.0
8.5
9.9
0~115 (-18~46)
14~75 (-10~24)
7.4 (3.5)
Performance
Nominal Cooling
Min.-Max. Cooling
Nominal Heating
Min.-Max. Heating
SEER
HSPF
EER
Cooling Operating Range
Heating Operating Range
Moisture Removal
Fan
Air Circulation: Hi
Outdoor
AOU24RLX
1
Pump Down
Changeover
2
36RSLX
Indoor
ABU24RULX
Saving
Auto
24RULX
Outdoor
AOU18RLX
1
18RULX
Note: Figures are based on 230 Volts.
38
39
SINGLE-ZONE MINI-SPLITS
18, 24, 36, 42,000 BTUh LARGE CASSETTE
HEAT PUMPS
SYSTEMS 18RCLX, 24RCLX, 36RCLX, 42RCLX
UP TO 16.0 SEER
Weekly
Cold
Ceiling
Pump Down
0˚F
Sensor
Cooling
164+ ft
Piping
Slender
1 Fresh air knockout available. Fresh air fan and ductwork field supplied. See design and technical manual for details. Fujitsu fresh air intake kit available part #KHRS940-25.
FUNCTION
APPLICATIONS
Up to 16-SEER, these models provide up to 30% increase
in efficiency over 13-SEER models. These models offer the
ability to send up to 38% of their capacity through two
branch ducts to adjacent rooms. Slender fit feature now
offered on all models decreases space required above the
ceiling increasing application opportunities.
Four-way airflow, concealed flush mount design and the
ability to operate in high ceiling rooms makes these systems
ideal for commercial applications such as offices, conference
rooms, restaurants, night clubs and bars in retrofit and new
construction. Long maximum combined piping lengths of
165 to 230 feet with 60 to 98 feet of height, depending
on model, allow the outdoor unit to be remotely located
up to 7 stories away and far from indoor unit. The ceiling
cassettes are also used in new construction condominiums
and homes taking advantage of their branch duct capability
to feed adjacent rooms. These heat pumps provide up to 30%
additional available heat when compared to conventional
models.
SLENDER FIT
Cassette body can be moved downward into the room 1-3/8”
to accommodate limited ceiling space.
°F (°C)
°F (°C)
Moisture Removal
Pt./h (l/h)
5.3 (2.5)
6.4 (3.0)
8.5 (4.0)
11.6 (5.5)
Fan
Air Circulation: Hi
Medium
Low
CFM (m3/h)
CFM (m3/h)
CFM (m3/h)
559 (950)
477 (810)
394 (670)
618 (1,050)
536 (910)
436 (740)
942 (1,600)
824 (1,400)
677 (1,150)
1,000 (1,700)
854 (1,450)
736 (1,250)
3 + Auto
3 + Auto
3 + Auto
3 + Auto
dB(A)
dB(A)
dB(A)
dB(A)
42/40 (Clg/Htg)
39/38 (Clg/Htg)
36/36 (Clg/Htg)
51/53 (Clg/Htg)
45/43 (Clg/Htg)
43/39 (Clg/Htg)
38/35 (Clg/Htg)
53/55 (Clg/Htg)
48/48 (Clg/Htg)
45/45 (Clg/Htg)
41/41 (Clg/Htg)
54/55 (Clg/Htg)
50/50 (Clg/Htg)
48/48 (Clg/Htg)
44/44 (Clg/Htg)
55/56 (Clg/Htg)
Amps
Amps
Amps
kW
kW
208-230/60/1
20
7.0/12.5
8.9/12.5
1.61/2.88
2.05/2.88
208-230/60/1
20
9.2/12.5
10.4/12.5
2.10/2.88
2.37/2.88
208-230/60/1
30
18.3/18.8
16.1/18.8
4.22/4.35
3.70/4.35
208-230/60/1
30
20.3/21.7
18.8/21.7
4.66/4.99
4.31/4.99
Fan Speed Stage
Sound
Indoor Sound Level (Clg/Htg): Hi
Medium
Low
Outdoor Sound Level Clg/Htg
Electrical
Voltage/Frequency/Phase
Circuit Breaker
Current Rated/Max: Cooling
Current Rated/Max: Heating
Power Use Rated/Max: Cooling
Power Use Rated/Max: Heating
Size & Weight
Net Weight
Dimensions: Height
Width
Depth
Fujitsu provides knock-outs on all ceiling cassettes where contractors
can:
• Install optional field supplied branch ducts on up to two sides to
supply up to 18% capacity per side to adjoining spaces up to 16
feet away. See Design and Technical Manual for details.
• Allows fresh air to be brought into the indoor unit using fresh air
knockout.
40
lbs. (kg)
Inch
mm
Inch
mm
Inch
mm
Refrigerant
Additional Data
Air Direction: Horizontal
Vertical
Air Filter
Front Grille
Minimum Lineset Length
Ft (m)
Maximum Lineset Length
Ft (m)
Max. Vertical Diff.
Lineset Size
Ft (m)
Inch
Suc. 1/2
75 (34)
9-3/4
246
32-3/4
830
32-3/4
830
Dis. 1/4
141 (64)
32-3/4
830
35-1/2
900
13
330
Suc. 5/8
75 (34)
9-3/4
246
32-3/4
830
32-3/4
830
Dis. 3/8
141 (64)
32-3/4
830
35-1/2
900
13
330
Suc. 5/8
82 (37)
11-5/8
296
32-3/4
830
32-3/4
830
Dis. 3/8
141 (64)
32-3/4
830
35-1/2
900
13
330
Suc. 5/8
88 (40)
11-5/8
296
32-3/4
830
32-3/4
830
Dis. 3/8
231 (105)
50-7/8
1290
35-1/2
900
13
330
Automatic
Washable
Removable
16 (5)
165 (50) Each
Automatic
Washable
Removable
16 (5)
165 (50) Each
Automatic
Washable
Removable
16 (5)
165 (50) Each
Automatic
Washable
Removable
16 (5)
230 (70) Each
(pre-charge: 49’)
(pre-charge: 49’)
(pre-charge: 49’)
(pre-charge: 66)
66 (20)
Suc. 1/2
Dis. 1/4
66 (20)
Suc. 5/8
Dis. 3/8
98 (30)
Suc. 5/8 Dis. 3/8
98 (30)
Suc. 5/8
Dis. 3/8
Outdoor
AOU42RLX
Fresh
42,700
13,700~45,000
45,200
14,300~54,600
15.0
8.5
9.2
0~115 (-18~46)
0~75 (-18~24)
Indoor
AUU42RCLX
Dry
34,100
8,500~36,000
36,000
9,200~42,700
14.0
8.5
8.1
0~115 (-18~46)
14~75 (-10~24)
Outdoor
AOU36RLX
Daisy
Restart
22,200
5,000~27,300
24,200
5,000~29,000
15.0
8.5
10.6
0~115 (-18~46)
14~75 (-10~24)
BTUh
BTUh
BTUh
BTUh
Indoor
AUU36RCLX
16
Pump
Up/Down
17,800
5,000~21,500
21,000
5,000~25,600
16.0
8.5
11.1
0~115 (-18~46)
14~75 (-10~24)
Performance
Nominal Cooling
Min.-Max. Cooling
Nominal Heating
Min.-Max. Heating
SEER
HSPF
EER
Cooling Operating Range
Heating Operating Range
Outdoor
AOU24RLX
Branch
Adjust
42RCLX
Indoor
AUU24RCLX
Changeover
36RCLX
Outdoor
AOU18RLX
Saving
1
24RCLX
Indoor
AUU18RCLX
Auto
18RCLX
Note: Figures are based on 230 Volts.
41
MULTI-ZONE MINI-SPLITS
MULTI-ZONE
MINI-SPLIT SYSTEMS
Operate as few as one indoor unit
or all indoor units
z
Choose from 4 indoor unit styles - wall
mount, slim duct, compact cassette, and
floor mount
z
YEAR-ROUND, WHOLE
HOME OR BUSINESS
COMFORT
Halcyon Systems are some of today’s most advanced forms of
heating and air conditioning. Multi-zone outdoor units can
operate from 2 to 8 indoor units simultaneously. Fujitsu’s
systems are super quiet as well as highly energy efficient.
Six combinations are ENERGY STAR®
qualified
z
Create hundreds of combinations
based on indoor type and BTUh
z
MULTI-ZONE AND XLTH SERIES SYSTEMS
18, 24, 36, AND 45,000 BTUh
AOU18RLXFZ
AOU18RLXFZH
AOU24RLXFZ
AOU24RLXFZH
AOU36RLXFZ1
AOU36RLXFZH
AOU45RLXFZ
CONNECTABLE CAPACITY
zConnect
2 to 5 indoor units, depending on model
zConnect
14,000 to 54,000 BTUh
zNo
branch boxes or separation tubes required
This allows connectable indoor units’ total capacity to exceed outdoor unit capacity. See Allowable Combination Table on
page 64.
If all indoor units are cooling or heating at the same time, the system will limit their capacity so that their total matches the
outdoor unit’s capacity. When a zone meets a desired set temperature it requires less capacity. The unused capacity is then
distributed to the remaining indoor units, increasing their capacity.
FOR EXAMPLE
18, 24, 36,000 BTUh
zConnect
2 to 4 indoor units, depending on model
zConnect
14,000 to 39,000 BTU
zeXtra
zNo
Low Temp Heating down to -15°F outdoor temps
branch boxes or separation tubes required
The load on a 3-bedroom home with a living room and kitchen downstairs and 3 bedrooms upstairs is 39,000 BTUh (21,000
BTU downstairs and 18,000 BTU upstairs). However the family isn’t upstairs and downstairs at the same time, therefore not
all units will be running simultaneously allowing 100% heating or cooling to occupied spaces. This can be achieved by our
AOU36RLXFZ1 outdoor unit.
HFI SERIES SYSTEM 48,000 BTUh
AOU48RLXFZ1
130% CONNECTABLE CAPACITY
The HFI system is rated at 48,000 BTUh but you can connect up to 130%, or 62,000 BTUh of rated indoor unit capacity to the
AOU48RLXFZ1. Connectable capacity allows you to connect indoor units that can exceed outdoor unit capacity. However, if
you connect indoor units that exceed 100% of the outdoor unit’s capacity there are limitations.
zConnect
z80
to 130% connectable capacity
zConnect
zBranch
42
2 to 8 indoor units
39,000 to 62,000 BTU
boxes and separation tubes required
If all indoor units are cooling or heating at the same time, the system will limit their capacity so that their total matches the
outdoor unit’s capacity. When a zone meets a desired set temperature it requires less capacity. The unused capacity is then
distributed to the remaining indoor units, increasing their capacity.
FOR EXAMPLE
The load on a small 2-story office building with a business downstairs and worker apartments upstairs is 62,000 BTUh
(38,000 BTUh downstairs and 24,000 BTUh upstairs) but the workers aren’t upstairs and downstairs at the same time,
therefore not all units will be running simultaneously allowing 100% heating or cooling to occupied spaces.
43
MULTI-ZONE MINI-SPLITS
INDIVIDUAL ZONING: PERSONALIZED WHOLE HOME COMFORT
MIX AND MATCH FLEXIBILITY
The ability to create the right combinations, the right quantity (up to 8-zones),
the right style indoor units, and the right capacity. It’s the RIGHT choice for your
home or business.
WALL MOUNTS
WALL MOUNTED
They mount high on a wall, out of sight and do not
require ductwork, increasing energy efficiency.
• Quiet
9
ASU7, 9, 12RLF1
ASU15RLF1
ASU18RLF
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
ASU24RLF
operation
• Easy
maintenance
• High
delivered efficiency means lower utility bills
MULTI-ZOME INDOOR UNITS
FLOOR MOUNTS
9
AGU9, 12RLF
AGU15RLF
SLIM DUCT
Mounted in a ceiling or in a framed enclosure below a
ceiling. They use minimal ductwork and remain very
energy efficient.
SLIM DUCTS
9
ARU7, 9, 12RLF
ARU18RLF
ARU24RLF
• Concealed
and out of sight
• Look
of central air with the efficiency of a mini-split
• Less
ducts = higher efficiency
COMPACT CASSETTES
9
AUU7, 9, 12RLF
AUU18RLF
9
9
OTHER
9
9
SEPARATION TUBES: UTP-SX248A
BRANCH BOXES: UTP-PU03A, B
COMPACT CASSETTE
Cassettes are extremely discreet, with only the
grille showing in the ceiling. They use the latest fan
technology to distribute the conditioned air evenly.
• Wired
remote control (wireless is optional)
• Powerful
• Fits
AOU18RLXFZ
AOU24RLXFZ
AOU36RLXFZ1
AOU45RLXFZ
turbo fan operation
into a standard 2’ x 2’ ceiling grid
AOU48RLXFZ1
FLOOR MOUNTED
AOU18RLXFZH
AOU24RLXFZH
AOU36RLXFZH
MULTI-ZONE OUTDOOR UNITS
44
Floor mount systems are ideal for residential radiator
replacements or any room with limited upper wall space,
like a kitchen or sunroom.
• Compact
size fits easily under a standard window
• Features
twin airflow for improved heat delivery
• Designer
wireless remote control
45
MULTI-ZONE MINI-SPLITS
7, 9, 12, 15, 18, 24,000 BTUh WALL MOUNT
HFI ASU7RLF1,
MULTI-ZONE INDOOR
ASU7, 9, 12, 15RLF1
1
Auto
Economy
Minimum Heat
2
3
Adjust
Changeover
4-Way
4
Up/Down
ASU18, 24RLF
Restart
Dry
5
Quiet Mode
24 Hour
Sleep
Performance
Nominal Cooling
Nominal Heating
Fan
Air Circulation: Hi
Weekly
Medium
Cold
6
Ion
Sensor
I/O
3rd Party
7
16
Daisy
164+ ft
8
Low
Piping
1 Applies when properly registered AND installed by a Fujitsu Elite Contractor in a
residence. See full warranty for details.
2 Auto Changeover is not designed to provide rapid changes between heating
and cooling operation or simultaneous heating and cooling. This feature is not
recommended for systems with more than one indoor unit unless all indoor units
have similar heating and cooling requirements and have similar temperature set
points. If all indoor units have similar heating and cooling requirements and have
similar temperature set points, auto changeover will work.
Quiet
3 RLF models only.
4 RLF1 models only.
5 RLF1 models: Available only with optional wired remote control.
6 Available only with optional wired remote control and optional interface kit.
7 Available only with optional interface kit.
8 Available only when used with Flex Zone AOU48RLXFZ1 outdoor unit.
Fan Speed Stage
Sound
Indoor Sound Level (Clg/Htg): Hi
Medium
Low
Quiet
Electrical
Voltage/Frequency/Phase
Current Rated: Cooling
Current Rated: Heating
Power Use Rated: Cooling
Power Use Rated: Heating
Size & Weight
Net Weight
Dimensions: Height
Width
Depth
Refrigerant
Additional Data
Air Direction: Horizontal
Vertical
Primary Air Filter
Ion Deodorizing Filter
Apple-Catechin Filter
Lineset Size
ASU9RLF1, ASU12RLF1, ASU15RLF1,
ASU18RLF, ASU24RLF
ASU7RLF1
ASU9RLF1
ASU12RLF1
ASU15RLF1
ASU18RLF
ASU24RLF
BTUh
BTUh
7,000
8,100
9,000
10,200
12,000
13,500
14,000
16,300
18,000
20,000
24,000
27,000
CFM
(m3/h)
CFM
(m3/h)
CFM
(m3/h)
CFM
(m3/h)
Clg 330 (560)
Htg 330 (560)
Clg 353 (600)
Htg 353 (600)
Clg 388 (660)
Htg 388 (660)
Clg 430 (730)
Htg 430 (730)
Clg 542 (920)
Htg 542 (920)
Clg 659 (1,120)
Htg 647 (1,100)
Clg 294 (500)
Htg 294 (500)
Clg 306 (520)
Htg 306 (520)
Clg 330 (560)
Htg 330 (560)
Clg 353 (600)
Htg 362(615)
Clg 436 (740)
Htg 436 (740)
Clg 530 (900)
Htg 530 (900)
Clg 253 (430)
Htg 253 (430)
Clg 253 (430)
Htg 253 (430)
Clg 265 (450)
Htg 277 (470)
Clg 312 (530)
Htg 330 (560)
Clg 365 (620)
Htg 365 (620)
Clg 436 (740)
Htg 436 (740)
Clg 182 (310)
Htg 194 (330)
Clg 182 (310)
Htg 194 (330)
Clg 182 (310)
Htg 194 (330)
Clg 212 (360)
Htg 221 (375)
Clg 324 (550)
Htg 324 (550)
Clg 365 (620)
Htg 365 (620)
4+auto
4+auto
4+auto
4+auto
4+auto
4+auto
dB(A)
dB(A)
dB(A)
dB(A)
36/36
32/32
29/29
21/22
37/37
33/33
29/29
21/22
40/40
36/36
30/31
21/22
42/42
38/38
33/35
25/27
43/44
37/37
33/33
31/31
49/48
42/42
37/37
33/33
Amps
Amps
W
W
208-230/60/1
0.13
0.13
15
15
208-230/60/1
0.15
0.15
17
17
208-230/60/1
0.19
0.19
22
22
208-230/60/1
0.25
0.25
28
28
208-230/60/1
0.32
0.32
41
41
208-230/60/1
0.53
0.53
69
69
19 (8.5)
10-1/2
268
33-1/16
840
8
203
R410A
19 (8.5)
10-1/2
268
33-1/16
840
8
203
R410A
19 (8.5)
10-1/2
268
33-1/16
840
8
203
R410A
19 (8.5)
10-1/2
268
33-1/16
840
8
203
R410A
31 (14)
12-5/8
320
39-1/4
998
9
228
R410A
31 (14)
12-5/8
320
39-1/4
998
9
228
R410A
Manual
Auto
Washable
Disposable
Disposable
suc 3/8
Manual
Auto
Washable
Disposable
Disposable
suc 3/8
Manual
Auto
Washable
Disposable
Disposable
suc 3/8
Manual
Auto
Washable
Disposable
Disposable
suc 1/4 dis 1/2
Auto
Auto
Washable
Disposable
Disposable
suc 1/2
Auto
Auto
Washable
Disposable
Disposable
suc 5/8
lbs. (kg)
Inch
mm
Inch
mm
Inch
mm
Inch
The following combinations are ENERGY STAR¬ qualifying:
BUILT IN FILTRATION
LONG-LIFE ION DEODORIZATION FILTER
The filter deodorizes by powerfully decomposing absorbed
odors using the oxidizing and reducing effects of ions
generated by the ultra-fine-particle ceramic. The filter can
be used for approximately 3 years if it is washed with water
when dirty to restore its surface action.
46
APPLE-CATECHIN FILTER
Dust, mold spores and micro-organisms are absorbed onto
the filter by static electricity and growth is inhibited and
deactivated.
AOU18RLXFZ with (2) ASU9RLF1
AOU18RLXFZ with (1) ASU7RLF1 + (1) ASU12RLF1
AOU18RLXFZ with (1) ASU9RLF1 + (1) ASU12RLF1
AOU18RLXFZH with (2) ASU9RLF1
AOU24RLXFZ with (2) ASU7RLF1 + (1) ASU9RLF1
AOU24RLXFZH with (2) ASU7RLF1 + (1) ASU9RLF1
AOU36RLXFZH with (4) ASU9RLF1
47
MULTI-ZONE MINI-SPLITS
7, 9, 12, 18, 24,000 BTUh SLIM DUCT
HFI
MULTI-ZONE INDOOR
1
2
Economy
I/O
3rd Party
Minimum Heat
4
16
Pump
Daisy
Changeover
164+ ft
3
Auto
Adjust
Restart
Dry
2
Quiet Mode
24 Hour
2
Weekly
Sleep
Cold
Sensor
5
Piping
1 Applies when properly registered AND installed by a Fujitsu Elite Contractor in a residence. See full warranty for details.
2 Available only with optional wireless remote control.
3 Auto Changeover is not designed to provide rapid changes between heating and cooling operation or simultaneous heating and cooling. This feature is not recommended for
systems with more than one indoor unit unless all indoor units have similar heating and cooling requirements and have similar temperature set points. If all indoor units have
similar heating and cooling requirements and have similar temperature set points, auto changeover will work.
4 Availabe lonly with optional interface kit.
5 Available only when used with Flex Zone AOU48RLXFZ1 outdoor unit.
FLEXIBLE INSTALLATION
SLIM DUCT
Horizontal or vertical, though internal drain pump will not
operate when the unit is mounted in a vertical configuration.
Adaptable when ceiling cavity is small and there is no slope
for drain.
Traditional
Compact Duct
Drain
Pump
13”
9.4”
18,000
20,000
24,000
27,000
Air Circulation: Hi
CFM (m3/h)
323 (550)
353 (600)
383 (650)
554 (940)
783 (1,330)
Medium
CFM (m3/h)
288 (490)
324 (550)
353 (600)
518 (880)
730 (1,240)
Low
CFM (m3/h)
276 (470)
294 (500)
324 (550)
483 (820)
648 (1,100)
Quiet
CFM (m3/h)
259 (440)
265 (450)
283 (480)
442 (750)
607 (1,030)
4 + Auto
4 + Auto
4 + Auto
4 + Auto
4 + Auto
dB(A)
dB(A)
dB(A)
dB(A)
28/28
26/26
25/25
24/24
28/28
27/26
26/25
25/24
29/29
28/28
27/27
26/24
32/33
31/32
30/31
29/29
33/35
32/34
30/32
29/29
W. C.
Amps
Amps
W
W
208-230/60/1
0 ~ 0.36
0.30
0.30
33
33
208-230/60/1
0 ~ 0.36
0.30
0.30
49
49
208-230/60/1
0 ~ 0.36
0.35
0.35
58
58
208-230/60/1
0 ~ 0.36
0.44
0.44
73
73
208-230/60/1
0 ~ 0.20
0.66
0.66
111
111
37 (17)
7-25/32
198
27-9/16
700
24-13/32
620
5-15/16
151
25-19/32
650
3/4
19
6
152
22
559
3/4 (Flat)
19 (Flat)
R410A
41 (19)
7-25/32
198
27-9/16
700
24-13/32
620
5-15/16
151
25-19/32
650
3/4
19
6
152
22
559
3/4 (Flat)
19 (Flat)
R410A
41 (19)
7-25/32
198
27-9/16
700
24-13/32
620
5-15/16
151
25-19/32
650
3/4
19
6
152
22
559
3/4 (Flat)
19 (Flat)
R410A
50 (23)
7-25/32
198
35-7/16
900
24-13/32
620
5-15/16
151
33-15/32
850
3/4
19
6
152
30
762
3/4 (Flat)
19 (Flat)
R410A
59 (27)
7-25/32
198
43-5/16
1,100
24-13/32
620
5-15/16
151
41-11/32
1,050
3/4
19
6
152
37-3/4
959
3/4 (Flat)
19 (Flat)
R410A
Washable
suc 3/8 dis 1/4
Washable
suc 3/8 dis 1/4
Washable
suc 3/8 dis 1/4
Washable
suc 1/2 dis 1/4
Washable
suc 5/8 dis 1/4
Fan Speed Stage
Sound
Indoor Sound Level (Clg/Htg): Hi
Medium
Low
Quiet
Electrical
Voltage/Frequency/Phase
Static Pressure
Current Rated: Cooling
Current Rated: Heating
Power Use Rated: Cooling
Power Use Rated: Heating
Size & Weight
Net Weight
Dimensions: Height
Return Duct
Dimensions: Height
Width
48
CFM
Typical Filter Size
Velocity, FPM
Unit External SP, in. W.C.
323
12 x 20
194
0.36
353
12 x 20
212
0.36
SP Loss, in. W.C.
Available Static Pressure
0.04
0.32
SP Loss, in. W.C.
Available Static Pressure
0.10
0.26
SP Loss, in. W.C.
Available Static Pressure
0.06
0.30
ARU18RLF
383
554
12 x 20
14 x 25
230
228
0.36
0.36
1” Fiberglass Filter
0.04
0.05
0.04
0.32
0.31
0.32
1” MERV 8 Pleated Filter
0.12
0.14
0.14
0.24
0.22
0.22
2” MERV 8 Pleated Filter
0.07
0.08
0.08
0.29
0.28
0.28
ARU24RLF
785
18 x 30
209
0.20
ARU24RLF
12,000
13,500
Depth
ARU12RLF
ARU18RLF
9,000
10,200
Width
ARU9RLF
ARU12RLF
7,000
8,100
Supply Duct Flange
Dimensions: Height
ARU7RLF
ARU9RLF
BTUh
BTUh
Depth
Filters are sized to keep velocities and static
pressure loss low. This will ensure sufficient
static pressure is available for ductwork,
fittings and supply and return grilles.
Alternative filter sizes with equivalent face
areas can be used.
ARU7RLF
Performance
Nominal Cooling
Nominal Heating
Fan
Width
FIELD SUPPLIED FILTERS
ARU7RLF, ARU9RLF, ARU12RLF,
ARU18RLF, ARU24RLF
Height
Refrigerant
Additional Data
Air Filter
Lineset Size
lbs. (kg)
Inch
mm
Inch
mm
Inch
mm
Inch
mm
Inch
mm
Inch
mm
Inch
mm
Inch
mm
Inch
mm
Inch
0.04
0.16
0.12
0.08
0.07
0.13
49
MULTI-ZONE MINI-SPLITS
7, 9, 12, 18,000 BTUh COMPACT CASSETTES
HFI
AUU7RLF, AUU9RLF, AUU12RLF, AUU18RLF
MULTI-ZONE INDOOR
1
2
Economy
Cold
Minimum Heat
Ceiling
Auto
Sensor
Adjust
Changeover
I/O
3
Up/Down
5
3rd Party
16
Pump
Daisy
Dry
Restart
164+ ft
4
Fresh
2
Quiet Mode
24 Hour
2
Sleep
Weekly
6
Piping
1 Applies when properly registered AND installed by a Fujitsu Elite Contractor in residence. See full warranty for details.
2 Available only with optional wireless remote control.
3 Auto Changeover is not designed to provide rapid changes between heating and cooling operation or simultaneous heating and cooling. This feature is not recommended for
systems with more than one indoor unit unless all indoor units have similar heating and cooling requirements and have similar temperature set points. If all indoor units have
similar heating and cooling requirements and have similar temperature set points, auto changeover will work.
4 Requires Fujitsu’s Optional Fresh Air Kit part #UTZ-VXAA. Allows for a 4-inch flex duct connection. Requires a field supplied duct booster fan capable of 60 CFM at .2”W.C. or
90 CFM at .4”W.C. For fan static pressure requirements, see installation manual. Add hood, filter and duct losses for fan total static pressure requirements. Will add 4” to the
height of the indoor unit.
5 Available only with optional Interface kit. Operation monitoring and On/Off control only.
6 Available only when used with Flex Zone AOU48RLXFZ1 outdoor unit.
EASY INSTALLATION
2-STAGE TURBO FAN
Fits into a standard ceiling tile. Dimensions of outer grille are
27-9/16” x 27-9/16” and may overlap adjacent tiles.
Air distribution is evenly spread across the heat exchanger
by the 2 stage turbo fan which produces two separate airflow
streams.
22.5”
1-stage
Heat exchange
efficiency:
Increased 20%
AUU12RLF
AUU18RLF
BTUh
BTUh
7,000
8,100
9,000
10,200
12,000
13,500
18,000
20,000
Air Circulation: Hi
CFM (m3/h)
318 (540)
Clg or Htg
318 (540)
Clg or Htg
359 (610)
Clg or Htg
441 (750) Clg
471 (800) Htg
Medium
CFM (m3/h)
Low
CFM (m3/h)
Quiet
CFM (m3/h)
288 (490)
Clg or Htg
259 (440)
Clg or Htg
230 (390)
Clg or Htg
4+auto
288 (490)
Clg or Htg
259 (440)
Clg or Htg
230 (390)
Clg or Htg
4+auto
312 (530)
Clg or Htg
277 (470)
Clg or Htg
241 (410)
Clg or Htg
4+auto
359 (610) Clg
418 (710) Htg
306 (520) Clg
353 (600) Htg
241 (410) Clg
265 (450) Htg
4+auto
dB(A)
dB(A)
dB(A)
dB(A)
33/34
31/32
29/29
27/27
33/34
31/32
29/29
27/27
37/37
33/33
31/31
28/28
42/44
37/40
33/37
29/30
Amps
Amps
(kw)
(kw)
208-230/60/1
0.15
0.15
18
18
208-230/60/1
0.15
0.15
18
18
208-230/60/1
0.19
0.19
23
23
208-230/60/1
0.30
0.30
39
39
33 (15)
9-11/16
245
22-7/16
570
22-7/16
570
R410A
33 (15)
9-11/16
245
22-7/16
570
22-7/16
570
R410A
33 (15)
9-11/16
245
22-7/16
570
22-7/16
570
R410A
33 (15)
9-11/16
245
22-7/16
570
22-7/16
570
R410A
Automatic
Washable
UTG-CCGF*
1-15/16 (49)
27-9/16 (700)
27-9/16 (700)
suc 3/8
dis 1/4
Automatic
Washable
UTG-CCGF*
1-15/16 (49)
27-9/16 (700)
27-9/16 (700)
suc 3/8
dis 1/4
Automatic
Washable
UTG-CCGF*
1-15/16 (49)
27-9/16 (700)
27-9/16 (700)
suc 3/8
dis 1/4
Automatic
Washable
UTG-CCGF*
1-15/16 (49)
27-9/16 (700)
27-9/16 (700)
suc 1/2
dis 1/4
Fan Speed Stage
Sound
Indoor Sound Level (Clg/Htg): Hi
Medium
Low
Quiet
Electrical
Voltage/Frequency/Phase
Current Rated: Cooling
Current Rated: Heating
Power Use Rated/Max: Cooling
Power Use Rated/Max: Heating
Size & Weight
Net Weight
Width
Depth
2-stage
AUU9RLF
Performance
Nominal Cooling
Nominal Heating
Fan
Dimensions: Height
22.5”
AUU7RLF
Refrigerant
Additional Data
Air Direction: Vertical
Air Filter
Front Grille
Grille Dim: Height
Width
Depth
Lineset Size
lbs. (kg)
Inch
mm
Inch
mm
Inch
mm
Inch (mm)
Inch (mm)
Inch (mm)
Inch
* Compact Cassette Grille UTG-CCGF sold separately. Must order one with each compact cassette.
Fresh Air Kit**
UTZ-VXAA
Mixes room air then passes through the
heat exchanger.
50
51
MULTI-ZONE MINI-SPLITS
9, 12, 15,000 BTUh FLOOR MOUNT
HFI
AGU9RLF, AGU12RLF, AGU15RLF
MULTI-ZONE INDOOR
AGU9RLF
AGU12RLF
AGU15RLF
Performance
1
Economy
Cold
Auto
2
Ion
Sensor
Adjust
Changeover
Minimum Heat
I/O
2
3
3rd Party
Up/Down
16
Daisy
Restart
2
Dry
Powerful
Quiet Mode
24 Hour
Sleep
Weekly
1 Applies when properly registered AND installed by a Fujitsu Elite Contractor in a residence. See full warranty
for details.
2 Available with optional wired remote control.
3 Available only with optional Interface kit. Operation monitoring and On/Off control only.
2-FAN AND WIDE AIRFLOW
FLEXIBLE AND EASY INSTALLATION
Having both upper and lower airflow quickly warms or cools
the entire room. Floor mount can be set in “Upward Airflow
Only” when occupants wish not to have feet warmed or
cooled.
Beneath
standard window
Standard
concave portion
Min. 37”
235/8”
279/16”
Min.
279/16”
Nominal Cooling
Nominal Heating
Fan
Air Circulation: Hi
Medium
Low
Quiet
Fan Speed Stage
Sound
Indoor Sound Level (Clg/Htg): Hi
Medium
Low
Quiet
Electrical
Voltage/Frequency/Phase
Current Rated: Cooling
Current Rated: Heating
Power Use Rated: Cooling
Power Use Rated: Heating
Size & Weight
Net Weight
Dimensions: Height
29-1/8”
Width
7-7/8”
Wall
Heating
Cooling
Fig. 1
Fig. 2
Fig. 1
Half concealed*
Window
Min.
231/4”
Fig. 2
1. Upon startup, both top and bottom louvers open. 1. Upon startup, both top and bottom louvers open.
2. As the room temperature nears the setpoint,
2. Closer to setpoint, only the top louver stays open
only the top louver stays open to help prevent
to help prevent cold drafts from windows.
cold air from falling.
Max. 5-7/8”
Min. 28-3/4”
Max. 3-1/8”
Depth
Refrigerant
Additional Data
Air Direction: Horizontal
Air Direction: Vertical
Apple Catechin Filter
Ion Deoderizing Filter
Connection Method
Lineset Size
BTUh
BTUh
9,000
12,000
14,200
12,000
16,000
18,000
CFM (m3/h)
CFM (m3/h)
CFM (m3/h)
CFM (m3/h)
312 (530)
259 (440)
212 (360)
159 (270)
4+Auto
353 (600)
288 (490)
224 (380)
159 (270)
4+Auto
383 (650)
306 (520)
235 (400)
159 (270)
4+Auto
dB(A)
dB(A)
dB(A)
dB(A)
39/39
34/34
28/28
22/22
42/42
36/38
30/32
22/22
44/44
38/39
31/33
22/22
Amps
Amps
(kw)
(kw)
208-230/60/1
0.15
0.15
16
16
208-230/60/1
0.18
0.18
18
18
208-230/60/1
0.20
0.20
23
23
31 (14)
31 (14)
31 (14)
23-5/8
23-5/8
23-5/8
600
600
600
29-1/8
29-1/8
29-1/8
lbs. (kg)
Inch
mm
Inch
mm
Inch
mm
Inch
740
740
740
7-7/8
7-7/8
7-7/8
200
200
200
R410A
R410A
R410A
Manual
Auto
Washable
Yes
Yes
Manual
Auto
Washable
Yes
Yes
Manual
Auto
Washable
Yes
Yes
Suc. 3/8
Dis. 1/4
Suc. 3/8
Dis. 1/4
Suc. 1/2
Dis. 1/4
*Field supplied insulation required
52
53
MULTI-ZONE MINI-SPLITS
FEATURES
HFI AOU18RLXFZ, AOU24RLXFZ, AOU36RLXFZ1,
18, 24, 36, 45,000 BTUh MULTI-ZONE OUTDOOR UNITS
AOU45RLXFZ
AOU18RLXFZ
ASU9+ASU9
AOU24RLXFZ
ASU9+ASU7+ASU7
AOU36RLXFZ1
ASU9 x 4
AOU45RLXFZ
ASU9 x5
Performance
AOU36RLXFZ1
AOU18, 24RLXFZ
AOU45RLXFZ
COMPACT SIZE
The compact size of the outdoor units allows for many
installation opportunities.
Connectable Indoor Units
2
2 to 3
2* to 4
2 to 5
Connectable Unit Capacity Class
BTUh
14 to 21,0001
14 to 27,0001
27 to 39,0001
34 to 54,000
Rated Capacity Cooling / Heating
BTUh
Cooling Operating Range
°F (°C)
Heating Operating Range
°F (°C)
18,000 / 22,000
14~115
(-10~46)
5~75
(-15~24)
22,000 / 24,000
14~115
(-10~46)
5~75
(-15~24)
35,200 / 36,400
14~115
(-10~46)
5~75
(-15~24)
45,000 / 48,000
14~115
(-10~46)
5~75
(-15~24)
Electrical
Rated Input Power Clg/Htg
kW
Voltage/Frequency/Phase
Outdoor unit
Contractors can select either an 18, 24, 36 or 45,000 BTU
outdoor unit combined with wall mounted, slim duct,
compact cassette or floor mount type indoor units. Mixand-match flexibility of evaporator type and capacity allows
you to choose the indoor unit that best fits the application,
whether it be hidden or showcased. These systems are
ideal for nursing homes, doctor’s offices, condominiums,
apartments and residences - any place where individual
cooling or heating is needed.
1.44/1.87
1.76/1.73
3.52/3.00
4.28/3.88
208-230/60/1
208-230/60/1
208-230/60/1
208-230/60/1
Maximum Total Current
Amps
10.0
13.7
20.3
23.8
Minimum Circuit Ampacity
Amps
12.1
16.7
24.6
28.9
Maximum Circuit Breaker
Amps
Fan: Type x Quantity
15
20
30
30
Propeller x 1
Propeller x 1
Propeller x 1
Propeller x 1
Sound Pressure Level Cooling
dB(A)
49
51
53
53
Sound Pressure Level Heating
dB(A)
49
52
55
55
Lineset Requirements
DC TWIN ROTARY COMPRESSOR
R
24” minimum
clearance
required
A high performance, low noise, large
capacity DC twin rotary compressor is used.
d.
Minimum Lineset Length Each
ft(m)
16 (5)
16 (5)
16 (5)
16 (5)
Maximum Lineset Length Each
ft(m)
82 (25)
82 (25)
82 (25)
82 (25)
Minimum Lineset Length Total
ft(m)
49 (15)
49 (15)
66 (20)
49 (15)
Maximum Lineset Length Total
ft(m)
164 (50)
164 (50)
230 (70)
264 (80)
Pre-Charge Length Total
ft(m)
98 (30)
98 (30)
164 (50)
164 (50)
ft(m)
49 (15)
49 (15)
49 (15)
49 (15)
Maximum Lineset Height Difference Btwn
Outdoor Unit & Furthest Indoor Unit
Maximum Lineset Height Difference Btwn
Indoor Units
Lineset Diameter
ft(m)
33 (10)
33 (10)
33 (10)
33 (10)
Inch
Liq. 1/4 x 2
Suc. 3/8 x 2
Liq. 1/4 x 3
Suc. 1/2 x 1, 3/8 x 2
Liq. 1/4 x 4
Suc. 1/2 x 1, 3/8 x 3
Liq. 1/4 x 5
Suc. 1/2 x 2, 3/8 x 3
lbs. (kg)
119 (54)
124 (56)
149 (68)
205 (93)
Inch
27-9/16
27-9/16
32-11/16
39-5/16
Size & Weight
Net Weight
Dimensions: Height
Width
NOMINAL CAPACITIES, SEER AND HSPF RATINGS
Depth
Data below is based on AHRI 210/240 non-ducted wall mounted models.
Yellow rows represent systems that are ENERGY STAR® qualified.
Model
Indoor Unit
Type
Non-Ducted
Ducted
Mixed
Combination
9+9
9+9
9+9
AOU18RLXFZ
ASU7+ASU12 and
Specific
ASU9+ASU12
Non-Ducted
9+7+7
Ducted
9+7+7
AOU24RLXFZ
Mixed
9+7+7
Non-Ducted
9+9+9+9
AOU36RLXFZ1
Ducted
9+9+9+9
Mixed
9+9+9+9
Non-Ducted
9+9+9+9+9
Ducted
9+9+9+9+9
AOU45RLXFZ
Mixed
9+9+9+9+9
54
Cooling
Capacity Btu/h
95F
18,000
18,000
18,000
EER
SEER
18.0
16.0
17.0
Heating Maximum
Capacity Btu/h
17F
5F
16,300
13,900
16,300
13,900
16,300
13,900
12.5
12.1
12.3
47F
3.44
3.52
3.48
9.3
9.0
9.2
18,000
22,000
22,000
22,000
35,200
35,200
35,200
45,000
45,000
45,000
12.5
18.0
22,000
13,900
16,300
13,900
3.67
9.0
12.5
10.6
11.6
10.0
9.0
9.5
10.5
9.8
10.2
18.0
15.5
16.8
18.0
16.0
17.0
19.7
17.7
18.7
24,000
24,000
24,000
24,000
24,000
24,000
48,000
46,000
47,000
14,100
14,100
14,100
22,000
22,000
22,000
28,200
27,800
28,000
19,800
19,800
19,800
32,500
32,500
32,500
36,900
36,900
36,900
16,300
16,300
16,300
25,400
25,400
25,400
31,500
31,500
31,500
4.04
3.42
3.74
3.56
3.32
3.44
3.60
3.46
3.53
9.5
9.0
9.3
9.4
8.7
9.1
10.3
9.3
9.8
COP
700
700
830
998
35-7/16
35-7/16
35-7/16
38-3/16
mm
900
900
900
970
Inch
13
13
13
14-9/16
mm
Refrigerant
Heating Rated
Capacity Btu/h
47F
17F
22,000
13,900
22,000
13,900
22,000
13,900
mm
Inch
330
330
330
370
R410A
R410A
R410A
R410A
*18+18 is the only 2 indoor unit (ASU, ARU or AUU) combination and requires K9FZ1818
1
See table for allowed combinations within this connectable capacity range.
HSPF
Applies when properly registered AND
installed by a Fujitsu Elite Contractor in a
residence. See full warranty for details.
55
MULTI-ZONE MINI-SPLITS
18, 24, 36,000 BTUh XLTH MULTI-ZONE OUTDOOR UNITS
Other models may go as low as -5°F, however they do not
include a base heater and other advancements found in XLTH
models. See the full
story on page 14.
18, 24,000 BTUh
36,000 BTUh
The base of Fujitsu’s XLTH outdoor
condensing units.
IMPROVED HEATING CAPACITY
% of Heating Capacity
Heating capacity at low outdoor temperatures was improved
by adopting a large heat exchanger and a high capacity
compressor.
100
When temperatures reach 36°F,
a built-in heater warms the base
of the outdoor unit so that
condensation doesn’t freeze.
Without a heater, freezing
condensate can cause noise,
damage to the fan blade, condenser,
and system performance.
AOU24RLXFZH,
AOU36RLXFZH
AOU18RLXFZH
AOU24RLXFZH
AOU36RLXFZH
Performance
AMBIENT HEATING TEMPERATURE OF -15°F
Base Heater
HIGH-HEAT AOU18RLXFZH,
Base Drainage Holes
The contoured base design
discharges melted water
through many holes located
at the bottom of the unit.
Standard
Series
50
Series
47
5
-15
Ambient Temperature (F°)
Connectable Indoor Units
Connectable Unit Capacity Class
BTUh
2
14,000 to 21,000
2 to 3
14,000 to 27,000
2 to 4
27,000 to 39,000
Rated Capacity Cooling/Heating
BTUh
18,000/22,000
22,000/25,000
35,200/36,400
Cooling Operating Range
°F (°C)
14 to 115
(-10 to 46)
14~115
(-10~46)
14~ 115
(-10~46)
Heating Operating Range
°F (°C)
-15 to 75
(-26 to 24)
-15~75
(-26~24)
-15~75
(-26~24)
dB(A)
dB(A)
1.33/1.70
208-230/60/1
16.4
19.7
20
Propeller x 1
48
50
1.65/1.81
208-230/60/1
20.8
25.1
30
Propeller x 1
50
52
2.70/2.67
208-230/60/1
26.0
31.5
40
Propeller x 1
53
55
ft(m)
ft(m)
ft(m)
ft(m)
ft(m)
16 (5)
82 (25)
49 (15)
164 (50)
98 (30)
16 (5)
82 (25)
49 (15)
230 (70)
98 (30)
16 (5)
82 (25)
49 (15)
230 (70)
164 (50)
ft(m)
49 (15)
49 (15)
49 (15)
Maximum Lineset Height Difference Btwn Indoor Units
ft(m)
33 (10)
33 (10)
33 (10)
Lineset Diameter
Inch
Liq. 1/4 x 2
Suc. 3/8 x 2
Liq. 1/4 x 3
Suc. 1/2 x 1, 3/8 x 2
Liq. 1/4 x 4
Suc. 1/2 x 1, 3/8 x 3
134 (61)
32-11/16
830
35-7/16
900
13
330
R410A
146 (66)
32-11/16
830
35-7/16
900
13
330
R410A
205 (93)
39-5/16
998
38-3/16
970
14-9/16
370
R410A
Electrical
Rated Input Power Clg/Htg
Voltage/Frequency/Phase
Maximum Total Current
Minimum Circuit Ampacity
Maximum Circuit Breaker
Fan: Type x Quantity
Sound Pressure Level Cooling
Sound Pressure Level Heating
Lineset Requirements
Minimum Lineset Length Each
Maximum Lineset Length Each
Minimum Lineset Length Total
Maximum Lineset Length Total
Pre-Charge Length Total
Maximum Lineset Height Difference Btwn Outdoor Unit
& Furthest Indoor Unit
Size & Weight
Net Weight
Dimensions: Height
Width
Depth
Refrigerant
kW
Amps
Amps
Amps
lbs. (kg)
Inch
mm
Inch
mm
Inch
mm
NOMINAL CAPACITIES, SEER AND HSPF RATINGS
Data below is based on AHRI 210/240 non-ducted wall mounted models.
Yellow rows represent systems that are ENERGY STAR® qualified.
Model
AOU18RLXFZH
AOU24RLXFZH
AOU36RLXFZH
56
Indoor Unit
Type
Non-Ducted
Ducted
Mixed
Non-Ducted
Ducted
Mixed
Non-Ducted
Ducted
Mixed
Combination
9+9
9+9
9+9
9+7+7
9+7+7
9+7+7
9+9+9+9
9+9+9+9
9+9+9+9
Cooling
Capacity
Btu/h
95ÝF
18,000
18,000
18,000
22,000
22,000
22,000
35,200
35,200
35,200
EER
SEER
13.5
12.4
13.0
13.3
12.1
12.7
13.0
12.0
12.5
21.5
19.0
20.3
20.0
18.0
19.0
20.0
18.0
19.0
Heating Rated
Capacity
Btu/h
47ÝF
17ÝF
22,000
14,200
22,000
14,200
22,000
14,200
25,000
15,400
25,000
15,400
25,000
15,400
36,400
21,400
36,400
21,400
36,400
21,400
Heating Maximum
Capacity
Btu/h
17ÝF
5ÝF
23,600
22,000
23,600
22,000
23,600
22,000
26,400
25,000
26,400
25,000
26,400
25,000
39,300
36,400
39,300
36,400
39,300
36,400
COP
47ÝF
3.79
3.60
3.70
4.04
3.87
3.96
4.00
3.88
3.93
HSPF
10.3
9.0
9.7
10.3
9.0
9.7
10.3
9.3
9.8
Applies when properly registered AND
installed by a Fujitsu Elite Contractor in a
residence. See full warranty for details.
57
FEATURES
MULTI-ZONE MINI-SPLITS
48,000 BTUh FLEX-ZONE OUTDOOR UNIT
HFI AOU48RLXFZ1
AOU48RLXFZ1
Performance
Connectable Indoor Units
A Hybrid system is the blending of a complex VRF system
with the simplicity of a multi-zone system to create a hybrid
solution that shares the best of both systems.
Flex provides the ability to create the right combinations, the
right quantity (up to 8-zones), the right style indoor units,
and the right capacity. It’s the right choice for your home or
business.
An Inverter is a system that controls the rotational speed
(not just an ON/OFF signal) of an electric motor by adjusting
the frequency and voltage of the electrical power supplied to
the motor. The inverter constantly regulates the compressor
speed to its optimum energy usage, producing higher
refrigerant performance with less power consumption.
BTUh
Nominal Cooling
BTUh
48,000
Max Cooling
BTUh
51,100
Nominal Heating
BTUh
54,000
Low Temp. Heating 17°F
BTUh
40,000
Connectable Unit Capacity Class
Connectable Branch Boxes
COMPACT SIZE
The compact size of outdoor unit AOU48RLXFZ1 allows for
many installation opportunities.
• Connect
2 to 8 indoor units
• 80 to 130% connectable capacity
• Connect 39,000 to 62,000 BTU
SELF DIAGNOSTIC FEATURE
This printed circuit board provides three modes of diagnostics
- setting, monitoring and function mode, as well as error
codes. It also provides a
pre-commissioning check
function. Setting mode allows
optional functions to be
selected. Monitoring mode
provides temperature for
each thermistor, compressor
operation and other functions.
Function mode provides cooling test run, heating test run
and pump down operation.
DC TWIN ROTARY COMPRESSOR
PIPING FLEXIBILITY
A high performance, low noise, large capacity
DC twin rotary compressor is used. Includes
Quiet Mode for night operation.
1-3
BTUh
57,000
Cooling Operating Range
°F (°C)
23~115 (-5~46)
Heating Operating Range
°F (°C)
5~75 (-15~24)
Max Heating
2 Indoor Units
This system provides individual temperature control
throughout your home or business so each room, zone or
floor will be the temperature you set! An optional Central
Remote Controller is available which can control up to all 8
indoor units from one keypad.
18k BTUh + 24 k BTUh = 42k BTUh ··OK
12k BTUh + 24 k BTUh = 36k BTUh ··Not Allowed (below 80%)
Electrical
Rated Input Power Cooling*
kW
5.52 / 5.19 / 5.35
8 Indoor Units
Rated Input Power Heating*
kW
5.02 / 4.89 / 4.96
7k BTUh × 8 units = 56k BTU ··OK
9k BTUh × 8 units = 72k BTU ··Not Allowed (over 130%)
Voltage/Frequency/Phase
Amps
24.5 / 23.0 / 23.7
Maximum Current: Outdor Heating
Amps
22.3 / 21.7 / 22.0
Maximum Circuit Breaker
Amps
SEER
HSPF
EER
Ducted
14.7
9.3
8.7
Non-Ducted
17.0
9.8
9.25
Mixed
15.8
9.5
8.97
40” minimum
clearance
required
Maximum Current: Outdor Cooling
208-230/60/1
Fan: Type x Quantity
Fan Motor Output
40
Propeller x 1
W
111
Sound Pressure Level Cooling
dB(A)
56
Sound Pressure Level Heating
dB(A)
58
ft(m)
377 (115)
ft(m)
49 (15)
ft(m)
98 (30)
Maximum Lineset Height Difference Btwn
Outdoor Unit & Furthest Indoor Unit
ft(m)
98 (30)
Maximum Lineset Height Difference Btwn
Indoor Units
ft(m)
49 (15)
Lineset Diameter
Inch
3/8 (Liq.) 5/8
(Suc.)
lbs. (kg)
216 (98)
Lineset Requirements
Maximum Lineset Length Total
Max. Pipe Length Between Box &
Farthest Indoor Unit
Max. Pipe Height Difference Between
Outdoor Unit & Branch Box)
Size & Weight
Net Weight
Dimensions: Height
Contractors can choose
the best direction for
piping from the outdoor
unit.
2-8
80~130% Nominal
(39,000~62,000)
Width
Back
Depth
Refrigerant
Inch
36
mm
914
Inch
38-1/4
mm
970
Inch
14-5/8
mm
370
R410A
37*Ducted / Non-Ducted / Mixed
Right
Front
Bottom
58
Applies when properly registered AND
installed by a Fujitsu Elite Contractor in a
residence. See full warranty for details.
59
MULTI-ZONE MINI-SPLITS
BRANCH BOXES
PIPING
b
UTP-PU03A, UTP-PU03B
UTP-PU03A
Primary
Connectable Indoor Unit
Max. Combination BTUh
Min. Combination BTUh
Clg. Operating Range °F(°C)
Htg. Operating Range °F(°C)
%RH
Voltage/Frequency/Phase
Maximum Current Ampacity (A)
Running Current Rated (A): Cooling
Heating
Power Use Rated (W): Cooling
Heating
1~3
62,000 Nom.*
7,000 Nom.*
25-115 (-5-46)
5-75 (-15-24)
80 or less
208-230/60/1
15
0.050
0.050
10
10
UTP-PU03B
Secondary
Dimensions: Gross (Flare to Flare):
Height x Width x Depth Inch
Height x Width x Depth mm
Dimensions: Net (Metal Box Only):
Height x Width x Depth Inch
Height x Width x Depth mm
Net Weight lbs. (kg)
Conn. Pipe Diameter - Main Inch
1~3
62,000 Nom.*
7,000 Nom.*
25-115 (-5-46)
5-75 (-15-24)
80 or less
208-230/60/1
15
0.050
0.050
10
10
Conn. Pipe Diameter - Branch Inch
Connection Method
Connection Adapter Included Inch
UTP-PU03A
Primary
UTP-PU03B
Secondary
7-5/8 x 33 x 14-5/8
195 x 838 x 370
7-5/8 x 33 x 14-5/8
195 x 838 x 370
7-5/8 x 17 x 14-5/8
195 x 433 x 370
7-5/8 x 17 x 14-5/8
195 x 433 x 370
20 (9)
20 (9)
(3/8 Liq. x 5/8 Suc.)
(1/4 Liq. x 1/2 Suc.)
3 pair
Flare
(3/8 Liq. x 5/8 Suc.)
(1/4 Liq. x 1/2 Suc.)
3 pair
Flare
(1/2MF x 3/8FF) x 3
(1/2MF x 5/8FF) x 3
(1/2MF x 3/8FF) x 3
(1/2MF x 5/8FF) x 3
No adapter needed
for 18k BTU
No adapter needed
for 18k BTU
c
Separation Tube
Assembly Kit
e
a
i
f
g
j
k
l
m
h
*As long as the total system nominal capacity is between 39,000 and 62,000 BTUh.
Warning: Branch boxes are not weather tight enclosures and cannot be mounted outdoors or in damp environments
exceeding 80% relative humidity, unless using the Branch Box Outdoor Enclosure, Part #UTP-PX-A.
Liquid pipe 3/8 inch
Gas pipe 5/8 inch
ALLOWED BRANCH BOX MOUNTING DIRECTION
Threaded Rod Mount
Horizontal Wall Mount
By reversing the
electrical box position
you can orient the inlet
and outlet pipes into a
left hand or right hand
configuration.
Vertical Wall Mount
By reversing the
electrical box position
you can orient the inlet
and outlet pipes into a
left hand or right hand
configuration.
You cannot reverse the
electrical box position
when mounting the
branch box vertically.
BRANCH BOX OUTDOOR ENCLOSURE
UTP-PX-A
The Branch Box Outdoor Enclosure is used to mount the indoor style Branch Box outdoors. The Branch Box Outdoor Enclosure
is a painted metal cover to match the condensing unit. When Branch Box Outdoor Enclosure is not required, see Installation
Manual for indoor mounting instructions.
Allowed Mounting Positions
Liquid pipe 1/4 inch
Gas pipe 3/8”, 1/2”, or 5/8”
*Branch box outlets are all 1/2” on gas pipe connections.
1/2” to 3/8” adaptors and 1/2” to 5/8” adaptors included (3 of each).
based on indoor unit size*
Flare connections
Branch Box to Indoor
Calculate
Refrigerant Charge
Factory Charge 7.6 lb (3.45 kg)
Unit pre-charged to 0 feet
1/4”
included
included
included
n/a
included
22 (10)
Net Branch Box + Cover
44.1(20)
Gross
30.9 (14)
SEPARATION TUBE ASSEMBLY KIT
Additional Refrig.
0.624 oz./ft. or 58g/meter
0.224 oz./ft. or 21g/meter
(Total length of 3/8” liquid line × 0.624 oz./ft. or 58g/meter ) + (Total length of 1/4” liquid line × 0.224 oz./ft. or 21g/meter )
(a+b+c+d+e) × 0.624 oz./ft. or 58g/meter + (f+g+h+i+j+k+l+m) × 0.224 oz./ft. or 21g/meter = additional refrigerant
Actual pipe length 230’ max.*
16’ min.
17’ min.
1’ min.
Piping length
between outdoor unit
and farthest branch
box 180’ max.
Height difference
between outdoor
and indoor units
98’ max.
UTP-SX248A
Liquid Inch
3/8 x 3/8 x 3/8
Suction Inch
5/8 x 5/8 x 5/8
Size
1/2”
5/8”
Location
Weight lbs. (kg)
Net Branch Box cover only
3/8”
Outdoor to Branch Box
Branch Box to Indoor Unit
3-15/16 x 33-11/16 x 20-5/16
(100 x 880 x 515)
Gross (HxWxD)
Gas pipe
3/8”
1/4”
8-11/16 x 32 x 17-7/8
(220 x 813 x 454)
Net (HxWxD)
60
Adaptor
Pipe Diameter
Total Pipe Length 377’ max.**
Dimensions in. (mm)
Liquid pipe
7,000 BTUh
9,000 BTUh
12,000 BTUh
18,000 BTUh
24,000 BTUh
Branch
Box
Height difference
between branch boxes
49’ max.
Branch Box
Pipe length
between
branch box
and indoor
unit 10’ min.
49’ max.
Height
difference
between indoor
and indoor
units 49’ max.
* Distance between outdoor unit & farthest indoor unit.
** Total liquid pipe or total gas pipe.
61
MULTI-ZONE MINI-SPLITS
SLIM DUCT
CASSETTE
WALL MOUNT
BRANCH
BOXES
SEPARATION
TUBES
WHOLE HOME
SOLUTIONS
flex
48,000 BTUh
AOU48RLXFZ1
zConnect
FLOOR
MOUNT
62
2 to 8 indoor units
z80 to 130% connectable capacity
zConnect 39,000 to 62,000 BTU
zBranch boxes and separation tubes required
Cool or heat one room, a few
rooms or an entire home.
63
MULTI-ZONE MINI-SPLITS
ALLOWABLE COMBINATIONS
ALLOWABLE COMBINATIONS CONT’D.
Select either an 18, 24, 36, 45 or 48,000 BTUh outdoor unit combined with wall mounted, slim duct, compact
cassette or floor mount type indoor units. Mix-and-match flexibility of evaporator type and capacity allows you to
choose the indoor unit that best fits the application, whether it be hidden or showcased.
CHOOSE INDOOR UNITS:
CHOOSE AN OUTDOOR UNIT:
AOU45RLXFZ
AOU36RLXFZ1
AOU48RLXFZ1
ASU7RLF1
ASU9RLF1
ASU12RLF1
ASU15RLF1
ASU18RLF
ASU24RLF
AOU36RLXFZH
AOU18RLXFZH
AOU24RLXFZH
12
24
45
7
9
12
18
46
7
7
7
9
18
48
9
15
15
39
7
9
12
24
52
7
7
7
9
24
54
7
9
16
9
9
18
36
9
15
18
42
7
9
15
15
46
7
7
7
12
12
45
7
12
19
9
12
12
33
9
15
24
48
7
9
15
18
49
7
7
7
12
15
9
9
18
9
12
15
36
9
18
18
45
7
9
18
18
52
7
7
7
12
9
12
21
9
12
18
39
9
18
24
51
7
12
12
12
43
7
7
7
12
12
12
36
12
12
12
36
7
12
12
15
46
7
7
12
12
15
39
12
12
15
39
7
12
12
18
49
7
7
7
7
7
28
12
12
18
42
7
12
15
15
49
7
7
7
9
30
12
15
15
42
7
12
15
18
7
7
7
12
33
12
15
18
45
7
15
15
7
7
7
15
36
12
15
24
51
9
9
7
7
7
18^
39
12
18
18
48
9
9
7
7
9
9
32
12
18
24
54
9
7
7
9
12
35
15
15
15
45
7
7
9
15
38
15
15
18
48
7
7
12
12
38
15
15
24
54
7
9
9
9
34
15
18
18
51
7
9
9
12
37
18
18
18
54
9
9
9
9
36
7
7
7
15
9
9
9
12
39
7
7
7
7
7
-
16
7
12
-
19
7
15
7
18
9
9
9
12
21
9
15
24
9
18
27
12
12
24
12
15
27
7
7
7
21
7
7
9
23
7
7
12
26
7
9
9
25
9
9
9
27
22
25
-
18
18
18
36
7
24
31
9
24
33
12
24
36
15
24
39
AOU45RLXFZ
AOU36RLXFZ1 / AOU36RLXFZH
18*
7
7
15
-
29
7
7
18
-
32
7
7
24
7
9
12
-
28
7
9
15
-
31
7
9
18
7
12
12
7
12
15
34
7
12
18
37
9
9
9
38
34
-
-
31
27
3 INDOOR UNITS MAX
36
18*
7
18
18
50
9
12
12
18
51
24
42
7
7
18
24
56
9
12
12
24
57
24
24
48
7
7
24
24
62
9
12
15
15
51
48
7
9
24
40
7
9
9
15
40
9
12
15
18
54
18
51
7
12
24
43
7
9
9
18
43
9
12
15
24
60
15
15
51
7
15
18
40
7
9
9
24
49
9
12
18
18
57
7
15
18
54
7
15
24
46
7
9
12
12
40
9
15
15
15
54
7
9
9
9
41
7
18
18
43
7
9
12
15
43
9
15
15
18
57
7
7
9
9
12
44
7
18
24
49
7
9
12
18
46
9
15
15
24
63
52
7
7
9
9
15
47
7
24
24
55
7
9
12
24
52
9
15
18
18
60
15
52
7
7
9
9
18
50
9
9
24
42
7
9
15
15
46
12
12
12
12
48
9
9
36
7
7
9
12
12
47
9
12
18
39
7
9
15
18
49
12
12
12
15
51
9
12
39
7
7
9
12
15
50
9
12
24
45
7
9
15
24
55
12
12
12
18
54
9
9
15
42
7
7
9
12
18
53
9
15
18
42
7
9
18
18
52
12
12
12
24
60
9
9
9
18
45
7
7
9
15
15
53
9
15
24
48
7
9
18
24
58
12
12
15
15
54
9
9
9
24
51
7
7
12
12
12
50
9
18
18
45
7
12
12
12
43
12
12
15
18
57
9
9
12
12
42
7
7
12
12
15
53
9
18
24
51
7
12
12
15
46
12
12
15
24
63
9
9
12
15
45
7
9
9
9
9
43
9
24
24
57
7
12
12
18
49
12
12
18
18
60
9
9
12
18
48
7
9
9
9
12
46
12
12
18
42
7
12
12
24
55
12
15
15
15
57
36
9
9
12
24
54
7
9
9
9
15
49
12
12
24
48
7
12
15
15
49
12
15
15
18
60
18
39
9
9
15
15
48
7
9
9
9
18
52
12
15
15
42
7
12
15
18
52
12
15
18
18
63
7
24
45
9
9
15
18
51
7
9
9
12
12
49
12
15
18
45
7
12
15
24
58
15
15
15
15
60
7
12
18
18
55
15
15
15
18
63
7
12
18
24
61
7
7
7
7
12
40
7
15
15
15
52
7
7
7
7
15
43
7
7
7
18
46
52
18
18
36
7
7
9
12
35
9
9
18
18
54
7
9
9
12
15
52
12
15
24
51
12
24
36
7
7
9
15
38
9
12
12
12
45
7
9
12
12
12
52
12
18
18
48
15
24
39
7
7
9
18
41
9
12
12
15
48
9
9
9
9
9
45
12
18
24
54
18
24
42
7
7
9
24
47
9
12
12
18
51
9
9
9
9
12
48
12
24
24
60
7
15
15
18
55
7
24
24
48
7
7
12
12
38
9
12
15
15
51
9
9
9
9
15
51
15
15
15
45
7
15
15
24
61
7
7
7
7
24
7
7
24
38
7
7
12
15
41
9
12
15
18
54
9
9
9
9
18
54
15
15
18
48
7
15
18
18
58
7
7
7
9
9
39
7
9
18
34
7
7
12
18
44
12
12
12
12
48
9
9
9
12
12
51
15
15
24
54
7
18
18
18
61
7
7
7
9
12
42
7
9
24
40
7
7
12
24
50
12
12
12
15
51
9
9
9
12
15
54
15
18
18
51
9
9
9
12
39
7
7
7
9
15
45
7
12
18
37
7
7
15
15
44
12
12
12
18
54
9
9
12
12
12
54
15
18
24
57
9
9
9
15
42
7
7
7
9
18
48
7
12
24
43
7
7
15
18
47
12
12
15
15
54
15
24
24
63
9
9
9
18
45
7
7
7
9
24
54
7
15
15
37
7
7
15
24
53
7
7
7
7
35
18
18
18
54
9
9
9
24
51
7
7
7
12
12
45
7
15
18
40
7
7
18
18
50
7
7
7
7
9
37
18
18
24
60
9
9
12
12
42
7
7
7
12
15
48
7
15
24
46
7
9
9
9
34
7
7
7
7
12
40
7
7
7
18
39
9
9
12
15
45
7
7
7
12
18
51
7
18
18
43
7
9
9
12
37
7
7
7
7
15
43
7
7
7
24
45
9
9
12
18
48
7
7
7
12
24
57
7
18
24
49
7
9
9
15
40
7
7
7
7
18
46
7
7
9
18
41
9
9
12
24
54
7
7
7
15
15
51
9
9
18
36
7
9
9
18
43
7
7
7
7
24
52
7
7
9
24
47
9
9
15
15
48
7
7
7
15
18
54
9
9
24
42
7
9
9
24
49
7
7
7
9
9
39
7
7
12
15
41
9
9
15
18
51
7
7
7
15
24
60
9
12
15
36
7
9
12
12
40
7
7
7
9
12
42
7
7
12
18
44
9
9
15
24
57
7
7
7
18
18
57
9
12
18
39
7
9
12
15
43
7
7
7
9
15
45
7
7
12
24
50
9
9
18
18
54
7
7
9
9
9
41
7
7
15
15
44
9
9
18
24
60
7
7
9
9
12
44
7
7
15
18
47
9
12
12
12
45
7
7
9
9
15
47
7
7
15
24
53
9
12
12
15
48
7
7
9
9
18
50
7
Actual rated cooling capacity of ASU15RLF1 is 14,000 BTU/h. * The optional kit “K9FZ1818 (UTP-MU36A2)” is necessary for dual zone system “18+18” with AOU36RLXFZ1 only. ^ Wall mounted type ASU18RLF cannot
be connected in this combination. “-” represents available circuit for future expansion when connecting this combination.
64
AOU48RLXFZ1
5 INDOOR UNITS MAX
9
7
18
5 INDOOR UNITS MAX
7
4 INDOOR UNITS MAX
14
2 INDOOR UNITS
3 INDOOR UNITS MAX
-
AGU9RLF
AGU12RLF
AGU15RLF
4 INDOOR UNITS MAX
9
33
4 INDOOR UNITS MAX
30
15
5 INDOOR UNITS MAX
12
9
4 INDOOR UNITS MAX
9
3 INDOOR UNITS MAX
9
9
7
AUU7RLF
AUU9RLF
AUU12RLF
AUU18RLF
= Allowed “Connectable Capacity” combinations between 100 and 130%
14
AOU36RLXFZH
2 INDOOR UNITS
24,000
7
7
-
18,000
7
AOU24RLXFZ / AOU24RLXFZH
4 INDOOR UNITS MAX
15,000
4 INDOOR UNITS MAX
2 INDOOR UNITS
AOU18RLXFZ / AOU18RLXFZH
12,000
2
INDOOR
9,000
4 INDOOR UNITS MAX
7,000
BTUh Capacity
ARU7RLF
ARU9RLF
ARU12RLF
ARU18RLF
ARU24RLF
3 INDOOR UNITS MAX
AOU18RLXFZ
AOU24RLXFZ
65
ACCESSORIES
MULTI-ZONE MINI-SPLITS
FEATURES
CONTROLS
ALLOWABLE COMBINATIONS CONT’D
Wired Remote Control
Wired Remote Control
Simple Remote Control
UTY-RNNUM
Group
UTY-RNBYU
Control
3-Wire
The wired remote control with
its unique lock function and sleek
design provides full feature access to property
managers, building owners, and facility
maintenance, as well as providing basic
comfort features to tenants, employees, and
teachers.
UTY-RVNUM
Group
3-Wire
Control
Features a large backlit LCD
display and displays the room
temperature. Provides full feature access to
property managers, building owners, and
facility maintenance, as well as providing
basic comfort features to tenants, employees,
and teachers.
UTY-RSNUM
Group
3-Wire
Control
Suitable when only basic operations
are required for hotels, offices and other
places where there is frequent arrival and
departure of occupants. Remote does not
allow any timer settings.
Remote Sensor
Simple Remote Control
Wired Remote
(Touch Panel)
UTY-XSZX
Wall mounted room temperature
sensor for slim duct models. Replaces room
temperature sensor in the return when
installed while still allowing for temperature
correction.
7,000
BTUh Capacity
9,000
12,000
18,000
15,000
Group
Control
2-Wire
UTY-RSRY
Backlit 2-wire remote with built in
temperature sensor. Offers set point
DGMXVWPHQWLQÝ)LQFUHPHQWV
(Compatible with System 30RLXEH)
24,000
12
12
12
12
55
7
7
7
7
12
12
52
7
7
7
7
12
15
55
7
9
9
24
56
7
12
12
12
15
58
7
7
9
12
12
47
7
12
12
12
18
61
7
7
7
7
12
18
58
7
7
9
12
15
50
7
12
12
15
15
61
7
7
7
7
15
15
58
7
7
9
12
18
53
7
12
15
15
15
64
7
7
9
12
24
59
9
9
9
9
9
45
7
7
9
15
15
53
9
9
9
9
12
48
7
7
9
15
18
56
9
9
9
9
15
51
7
7
9
15
24
62
9
9
9
9
18
54
7
7
9
18
18
59
9
9
9
9
24
60
12
12
12
50
7
7
12
12
15
53
7
7
12
12
18
56
7
7
12
12
24
62
7
7
12
15
15
56
7
7
12
15
18
59
7
7
12
18
18
62
12 56
7
7
7
7
7
9
15 59
7
7
7
7
7
9
18 62
7
7
7
7
7
12 12 59
IR Wireless Module
7
7
7
7
7
12 15 62
Model: FJ-IR-WIFI-1NA
Model: UTY-TFNXZ2
7
7
7
7
9
9
9
7
7
7
7
9
9
12 58
Works with
IntesisHome¬ app
Works with
FGLair¬ app
15 61
7
7
7
9
15
18
63
7
7
7
12
12
12
57
7
7
7
12
12
15
60
46
9
9
15
15
15
63
49
9
12
12
12
12
57
7
9
9
54
15
7
9
7
57
60
12
9
7
7
15
12
9
7
7
7
12
18
9
9
7
7
9
15
9
9
7
7
7
12
9
9
7
7
9
9
9
18 60
57
54
12
9
7
7
18
12
9
7
7
7
9
12
9
7
12
7
9
9
9
63
12
7
7
7
9
18
9
7
7
7
60
15
9
7
7
15
12
9
15 57
15
9
9
7
15
9
9
7
7
9
7
43
7
7
9
7
9
12
7
7
7
9
24
7
7
57
9
9
7
7
15
9
12
12 54
15
7
9
7
9
60
9
7
12
9
60
9
7
9
9
15
9
7
9
60
18
7
54
7
7
18
15
7
51
7
7
12
12
52
9
9
12
18
7
7
12
9
51
7
7
9
9
49
7
7
9
9
7
7
57
9
7
7
7
18
9
12 15 63
7
12
62
9
7
9
59
9
7
9
18
15 60
12 12 60
7
9
15
9
9
7
7
15
9
9
7
54
15
9
9
61
15
15
9
7
7
7
12
15
15
63
7
7
9
9
9
9
50
7
7
9
9
9
53
55
7
7
7
7
9
9
12 53
7
7
7
7
9
12 12 61
7
7
9
9
9
15 56
7
7
7
9
9
9
9
7
7
9
9
9
18 59
7
7
7
9
9
9
12 60
15 63
57
12
12
12
15
60
58
9
12
12
15
15
63
7
7
9
9
12 12 56
7
7
7
9
9
9
49
12
12
12
12
12
60
7
7
9
9
12 15 59
7
7
9
9
9
9
9
15
52
12
12
12
12
15
63
7
7
9
9
12 18 62
7
7
9
9
9
9
12 62
18
55
42
7
7
9
9
15 15 62
7
9
9
9
9
9
9
12
24
61
7
7
7
7
7
9
44
7
7
9
12 12 12 59
7
7
7
7
7
7
7
7 56
15
15
55
7
7
7
7
7
12
47
7
7
9
12 12 15 62
9
15
18
58
7
7
7
7
7
7
7
9 58
7
7
7
7
7
15
50
7
7
12 12 12 12 62
9
9
18
18
61
12
52
7
7
7
18
53
9
12
7
9
12
7
7
9
7
9
12
12
15
55
7
9
12
12
18
58
7
7
7
7
7
7
7
7
7
7
24
59
7
9
9
9
9
9
9
9
52
12 55
7
7
7
7
9
9
46
7
9
9
9
9
15 58
7
7
7
7
9
12
49
7
9
9
9
9
18 61
7
9
12
15
15
58
7
9
12
15
18
61
7
7
7
7
9
15
52
7
9
9
9
12 12 58
7
9
15
15
15
61
7
7
7
7
9
18
55
7
9
9
9
12 15 61
7
9
15
15
18
64
7
7
7
7
9
24
61
7
9
9
12 12 12 61
8 INDOOR UNITS MAX
9
7
UTY-LRHUM
3-Wire
For slim duct models.
Includes a wireless
remote control.
48
12
15
9
9
UTY-LNHUM
For spaces where there is just
no place to mount the wired
remote or where wireless operation is
preferred.
9
9
7
12 57
18
9
7
9
Receiver Unit
UTY-DMMUM
3-Wire
This remote controls up to 8
individual indoor units. Set temperatures
on timers to best meet individuals needs.
Includes a large backlit LCD and 4-way
navigation pad. Remote connects in daisy
chain to branch boxes.
9
9
7
9
Central Controller
15
51
7
9
Wireless Remote
Control
7
12
57
9
9
54
9
12
15
9
9
9
7
9
12
9
7
9
12
9
7
9
9
9
7
7
9
9
7
7 INDOOR UNITS MAX
7
9
7
7
6 INDOOR UNITS MAX
7
5 INDOOR UNITS MAX
7
6 INDOOR UNITS MAX
5 INDOOR UNITS MAX
66
7
6 INDOOR UNITS MAX
= Allowed “Connectable Capacity” combinations between 100 and 130%
AOU48RLXFZ1, con't.
59
Group Control: With this feature, multiple evaporators can be ‘daisy-chained’ together on one single remote control, allowing for multiple single-zoned systems installed in
an application to be grouped together by evaporator. The same feature can be used on a multi-zone system however, multiple multi-zone systems cannot be grouped together
nor can a single-zone system be group controlled with a multi-zone system. For additional information, see Engineering Bulletin # 036 and/or 037.
WI-FI DEVICES
See compatability table, page 13.
7
7
7
7
7
7
7 12 61
7
7
7
7
7
9
9 60
7
7
7
7
7
9
9
9 62
SAMPLE WI-FI APP SCREEN DISPLAYS
Wi-Fi Module
Wired Module
Model: FJ-RC-WIFI-1NA
Works with
IntesisHome¬ app
IntesisHome¬
61
7
Group
Control
UTY-RNRUZ1
2-Wire
Features a large backlit LCD display and
displays the room temperature. Provides full
feature access to property managers, building
owners, and facility maintenance, as well as
providing basic comfort features to tenants,
employees, and teachers.
(Compatible with System 30RLXEH)
FGLAir¬
ADDITIONAL CONTROLS
Network Converter
Thermostat Converter
UTY-VTGX
The Network Converter is used to control and monitor one or more
single-zone Halcyon indoor units (max of 16 IDU’s per converter)
through Airstage VRF Central Controllers.
UTY-TTRX
Control Halcyon products1 using a third party thermostat.
Up to 16 indoor units can be connected as a group to one
thermostat convertor.
^ Minimum Heat, Sleep Timer functions will be lost when the wired remote control is installed.
* Wall mounted ASU7, 9, and 12RLF1 require accessory interface kit (Part UTY-XCBXZ2) in order to connect this device to them. Wall mounted ASU9, 12, and 15RLS3/H require
accessory interface kit (Part UTY-TWBXF1) in order to connect this device to them.
1 NOT compatible with models ABU18/24RULX, ABU36RSLX, AUU18/24/36/42RCLX.
67
FEATURES
ACCESSORIES
Turns system on or off using a normally open
circuit. For example in home automation,
BMS integration of only On/Off operation,
occupancy sensor, key card switch, or lead-lag
control of other heating/cooling devices.
Required to connect ASU7RLF1, 9RLF1, and
12RLF1 to Wired Remotes UTY-RNNUM and
UTY-RVNUM, Dry Contact Wire Kit UTY-XWZX,
and Simple Remote Control UTY-RSNUM.
Required to connect the
ASU15RLS2/H+ and ASU9, 12, 15RLS3/H to
Wired Remotes UTY-RNNUM and UTY-RVNUM,
Dry Contact Wire Kit UTY-XWZXZ5, and Simple
Remote Control UTY-RSNUM.
Slim Duct
Connector Kit
UTD-ECS5A
Comes with 5 sets of wires. Can be used to
turn unit on/off, wire in float switch, AUX
heater, turn on an external device (Fan), or
show if the unit is running.
Outdoor Unit
Input/Output
Connector
Outdoor Unit
Base Heater
Connector
UTY-XWZXZ3
UTY-XWZXZ4
Gives the ability to limit the noise of the
unit*, stop the outdoor unit, limit power
consumption*, control the operating mode
(Htg/Clg), or use output status to see if the
compressor is running. You will need to order a
kit for each option.
Used to hook up an AUX base pan heater to
the outdoor unit. Heater will stop ice from
forming in the outdoor unit. Base heater will
operate when outdoor temperature is below
36°F. Heater is field supply. Heaters greater
than 25W can’t be fed directly from the board,
but have to be powered from another source.
Interface Kit
Interface Kit Box
UTY-XCSXZ1
UTZ-GXXB
Required to connect ASU30RLE to Dry Contact
Wire Kit UTY-XWZX3, and Lead Lag Control
function^.
* Will reduce capacity.
^ Wired remotes cannot be used when using
this feature. This includes UTY-RNRUZ1, UTYRVNUM, UTY-RNNUM, UTY-RSNUM.
Used to conceal Interface Kit UTY-XCSXZ1.
UTY-RNNUM Wired Remote Control
UTY-RVNUM
Wired Remote Control
(Backlit)
Simple Remote
Control 3-Wire
Simple Remote
UTY-RSKU
Control 2-Wire
Wireless Remote
UTY-LNHUM
Control
Remote
UTY-DMMUM Central
Control
UTY-RNRUZ1 Wired Remote Control
UTY-RSNUM
z3 z2 z2 z2 z2 z z z z z z z z z z z z z z z z z z z z z
z3
z
z
z3 z2 z2
z3 z2 z2 z2 z2 z z z z z z z z z z z z z z z z z z z z z
z3
z4 z4 z4 z4
z3 z2 z2
z3 z2 z2 z2 z2 z z z z z z z z z z z z z z z z z z z z z
z3
z
z1 z1 z1 z z z z
z z z
FJ-RC-WIFI-1NA
High Humidity
Insulation Kit
Air Outlet Shutter
Plate
Fresh Air
Intake Kit
Fresh Air
Intake Kit
UTD-ECS5A
UTZ-KXGC
UTR-YDZB
UTZ-VXAA
KHRS940-25
UTY-XWZXZ3
Additional insulation for
compact cassette units,
which may be needed when
they are installed in high
humidity areas.
In a 3-way air flow
configuration an Air
Outlet Shutter Plate kit is
required to block air flow
of 1 louver.
Mixes room air then passes it through
a heat exchanger. Allows for a 4-inch
flex duct connection. Requires a field
supplied duct booster fan capable of
60 CFM at .2”W.C. or 90 CFM at .4”W.C.
For fan static pressure requirements,
see installation manual.
Fresh air kit for RCLX/RULX/RSLX systems.
Kit contains Current Sensor with
Built-in Relay and Switching Power
Supply. Requires field supplied ductwork
and a fan capable of generating 15 CFM
at a static pressure of approximately
0.26” WC.
UTY-XWZXZ4
Slim Duct
Connector Kit
Outdoor Unit
Input/Output
Connector
Outdoor Unit Base
Heater Connector
Interface Kit
Interface Kit Box
UTY-XCSXZ1
UTZ-GXXB
FRESH AIR INTAKE KITS
UTZ-KXGC
UTR-YDZB
High Humidity
Insulation Kit
Air Outlet Shutter
Plate
Fresh Air Intake Kit
Fresh Air Intake
z
zz
z
Wi-Fi Device:
z z
IR Wireless Module
Wi-Fi Device:
Wired Module
z
z z z
z
z z z z z z z z z z z z z z z z z z z6 z6 z6 z z z
z z
z*
z*
z z z
z
z
z z z
z5 z5 z5 z5 z5 z5 z5 z5 z5 z5 z5 z5 z5 z5 z5 z z z z z z z z z z z z z z*
z
z z z
z z z
z
z
z z
z z z
z
z
z
z
z z z z z z z z z z z z z z z
z z
z
z
z z z
z
z z z z z
z
z z
z z z z
z z z z z z
z z
z z z
z
z z z z z z
z
z
z3
z
z z z
z
z
z
z
z
z
z z z
z
z z z
z
z z z
UTZ-VXAA
z z z z z z z
KHRS940-25
MISCELLANEOUS
Thermostat Converter z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z
UTY-TTRX
MISCELLANEOUS
z z
z
Remote Sensor
UTY-XSZX
Receiver Unit
UTY-LRHUM
WI-FI DEVICES
FJ-IR-WIFI-1NA
HFI MULTI-ZONE
AND FLEX-ZONE
LARGE
CASSETTE
z3 z2 z2
REMOTE CONTROLS
UTY-RNBYU Wired Remote Control
Wi-Fi Module
UTY-TFNXZ2
Wi-Fi Plug5
UTY-WIFI
INTERFACE KITS
Dry Contact Wire Kit
UTY-XWZX
UTY-XWZXZ5 Dry Contact Wire Kit
Interface Kit3
UTY-XCBXZ2
Interface Kit2
UTY-TWBXF1
FRESH AIR INTAKE KITS
UNIVERSAL
FLOOR /
CEILING
z
z
z
z z z
3-Pole Single Throw Safety Switch
R410A Swivel Adapter
Plug Model
UTY-VTGX
K3PST
K9R410A55
UTY-WIFI
K3PST
z
z
z z z
For use where code requires a
disconnect at the indoor unit.
In order to minimize incorrect charging of
systems with R22 Fujitsu uses a different
access port. Contractors will need this
55-degree swivel access fitting.
In order to connect certain models to Wired
Wi-Fi Module, FJ-RC-WIFI-1NA, this plug must
be used.
3-Pole Single Throw
z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z
Safety Switch
K9R410A55 R410A Swivel Adapter z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z
z
z
z z z
K9FZ1818
Condensate Pump
18+18 Combo Fittings Kit
Auto Louver Grille Kit
UTR-DPB24T
K9FZ1818
UTD-GXSA-W (for ARU7/9/12)
UTD-GXSB-W (for ARU18)
UTD-GXSC-W (for ARU24)
Auto Louver provides comfortable airflow and blends
in with various interiors. Grille can be connected
either directly to indoor unit or through the
rectangular duct. Only compatible with ARU models
with serial numbers greater than 2000.
OEM design plugs into
factory harness for ease of
installation. Rated for 11.8” of vertical
lift. Only used with System 36RSLX.
68
Allows two 18,000 BTU indoor units to be used
on an outdoor AOU36RLXFZ1. Requires special
piping; limited to only 18,000 BTU models.
Total BTU capacity is limited to 31,600 BTU in
cooling. The kit upsizes linesets to 3/8” and
1/2”.
UTR-DPB24T
Network Converter
z
18+18 Combo Fittings
Kit (for AOU36RLXFZ1)
Grille Kit
UTD-GXSB-W Auto Louver
(for ARU18)
UTD-GXSC-W
z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z
Condensate Pump
Louver Grille Kit
UTD-GXSA-W Auto(for
ARU9, 12)
Auto Louver Grille Kit
(for ARU24)
AOU45RLXFZ
AOU48RLXFZ1
UTY-TWBXF1
SLIM
DUCT
Cassette
Slim Duct
Floor Mount
UTY-XCBXZ2
FLOOR MOUNT CASSETTE
(18, 24k BTU)
UTY-XWZX/UTY-XWZXZ5
COMPACT
WALL MOUNTED
Large Wall
Interface Kit
(RLF1 - 7, 9, 12, 15k BTU)
Interface Kit
SINGLE-ZONE
18RCLX
24RCLX
36RCLX
42RCLX
Small Wall
Dry Contact Wire Kit*
ACCESSORY
COMPATIBILITY
9RL2
9RLFW1
9RLS3Y
9RLS3YH
12RL2
12RLFW1
12RLS3Y
12RLS3YH
15RLS3Y
15RLS3YH
18RLB
18RLXFW1
18RLXFWH
24RLB
24RLXFW1
24RLXFWH
30RLXB
30RLXEH
36RLXB
9RLFF
12RLFF
15RLFF
9RLFFH
12RLFFH
15RLFFH
9RLFCC
12RLFCC
18RLFCC
9RLFCD
12RLFCD
18RLFCD
18RULX
24RULX
36RSLX
INTERFACE KITS
z
z z
z
z
z
z
1 If using UTY-RNBYU with these models you need to change the dip switch SW-1 to “ON”. Refer to Tech Tip #028.
2 Wall mounted ASU9, 12, and 15RLS3Y/RLS3YH require accessory interface kit #UTY-TWBXF1 in order to connect these devices to them.
3 Wall mounted ASU7, 9, and 12RLF1 require accessory interface kit #UTY-XCBXZ2 in order to connect these devices to them.tt4 Only multi-zone models greater than specific serial numbers are compatible with UTY-RVNUM. See Service Bulletin 0031 for serial number compatibility.t
5 Plug model #UTY-WIFI required to connect these devices to them.
6 Wireless Receiver #UTY-LRHUM is required in order to connect this device.
* Requires accessory interface kit #UTY-XCBXZ2 and plug model #UTY-WIFI in order to connect these devices to them.
^ Requires accessory interface kit #UTY-TWBXF1 and plug model #UTY-WIFI in order to connect these devices to them.
69
MISCELLANEOUS
LINE SET SIZES AND LENGTHS
THINGS TO KNOW BEFORE YOU BUY A FUJITSU SYSTEM
z
z
z
z
z
z
z
42RCLX
36RCLX
24RCLX
z
18RCLX
z
36RSLX
z
24RULX
z
z
18RULX
z
18RLFCC
z
z
12RLFCC
z
9RLFCC
z
18RLFCD
z
12RLFCD
z
9RLFCD
z
36RLXB
z
30RLXB
z
30RLXEH
12RLS3H
z
24RLB
12RLS3
z
24RLXFWH
12RLFW1
z
24RLXFW1
12RLFFH
z
18RLXFWH
12RLFF
z
18RLXFW1
12RL2
z
18RLB
9RLS3H
z
15RLS3H
9RLS3
z
15RLS3
9RLFW1
z
15RLFFH
9RLFFH
z
15RLFF
9RLFF
1/4” x 3/8”
1/4” x 1/2”
1/4” x 5/8”
3/8” x 1/2”
3/8” x 5/8”
Total System
9RL2
SINGLE-ZONE SYSTEMS
COMPLETE SYSTEM WARRANTY
TRADEMARKS
Standard warranties vary depending on model:
The Fujitsu logo is a registered trademark of Fujitsu Limited. The Halcyon and Halcyon
HFI logos and names are trademarks of Fujitsu General America, Inc. ENERGY STAR® is
a registered trademark of the EPA and DOE. Copyright © 2017 Fujitsu General America,
Inc.
6 Year Compressor / 2 Year Parts warranty OR
z
z
z
z
z
Extended warranties include:
10 Year Compressor/Parts warranty for Halcyon systems that have been
installed by a licensed contractor and the online Product Registration* has
been submitted.
Max. Combined 66 66 66 66 66 66 66 66 66 66 66 66 66 66 66 66 66 165 165 165 165 66 246 165 165 66 66 66 66 66 66 165 165 165 165 165 165 230
Pipe Length ft (m) (20) (20)(20)(20)(20)(20)(20)(20)(20)(20)(20)(20)(20)(20)(20)(20)(20)(50)(50)(50)(50)(20)(75)(50)(50)(20)(20)(20)(20)(20)(20)(50)(50)(50)(50)(50)(50)(70)
12 Year Compressor/Parts warranty for Halcyon systems that have been
installed by an Elite Contractor and the online Product Registration* has been
submitted.
Min. Combined 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 16 16 16 16 10 16 16 16 10 10 10 10 10 10 16 16 16 16 16 16 16
Pipe Length ft (m) (3) (3) (3) (3) (3) (3) (3) (3) (3) (3) (3) (3) (3) (3) (3) (3) (3) (5) (5) (5) (5) (3) (5) (5) (5) (3) (3) (3) (3) (3) (3) (5) (5) (5) (5) (5) (5) (5)
z z z
z z
z z z
z z z
1/4” x 3/8”
z
z
z
z
1/4” x 1/2”
z
z
1/4” x 5/8”
z
z z
3/8” x 1/2”
z
3/8” x 5/8”
Total System
Max. Combined
165
Pipe Length ft (m)
(50)
Min. Combined
49
Pipe Length ft (m)
(15)
Each Indoor Unit Minimum and maximum pipe lengths for multi-zone units are found on pages 55, 57 and 60.
AOU48RLXFZ1
AOU45RLXFZ
AOU36RLXFZH
(18+18)
AOU36RLXFZ1
AOU36RLXFZ1
AOU24RLXFZH
AOU24RLXFZ
AOU18RLXFZH
AOU18RLXFZ
UTP-PU03A /B^
AUU18RLF x 2*
ARU18RLF x 2*
AGU18RLF x 2*
ASU18RLF x 2*
AUU18RLF
AUU12RLF
AUU9RLF
AUU7RLF
ARU24RLF
ARU18RLF
ARU12RLF
ARU9RLF
ARU7RLF
AGU15RLF
AGU12RLF
AGU9RLF
ASU24RLF
ASU18RLF
ASU12RLF1
ASU9RLF1
ASU7RLF1
MULTI / FLEX ZONE MODELS
165
(50)
49
(15)
165 165 230
(50) (50) (70)
49 49 66
(15) (15) (20)
131
(40)
49
(15)
230
(70)
49
(15)
264 377
(80) (115)
49 161 102
(15) (5)1(3)2
ASU
Wall Mount
ABU
Universal Mount
Ceiling Susp.
ARU
BTUh in
R=
thousands
C=
X
Cassette
F
L=
Inverter
S=
Ceiling
Susp.
X=
Extended
Line Set
Slim Duct
L=
Inverter
S=
Super
Efficient
AUU
Cassette Mount
U=
Universal
F=
HFI
AGU
Floor Mount
B=
230V
AOU
C=
Cooling only
* Residents of California and Quebec are not required to register the System in order to
obtain all of the rights and remedies applicable to this Warranty.
Indoor temperature: 80°F DB/67°F WB (26.7°C DB/19.4°C WB)
Outdoor temperature: 95°F DB/75°F WB (35°C DB/23.9°C WB)
•
Heating capacity is based on the following conditions:
Indoor temperature: 70°F DB (21.1°C DB)
Outdoor temperature: 47°F DB/43°F WB (8.3°C DB/6.1°C WB)
For full details, see Halcyon Warranty Statement.
WARNING
HEAT PUMP DISCLAIMER
Always use a licensed installer or contractor to install this product. Do not try to
install the product yourself. Improper installation can result in water or refrigerant
leakage, electrical shock, fire or explosion. Use only parts and accessories supplied
or specified by Fujitsu. Ask a licensed contractor to install parts and accessories. Use
of unauthorized or improper installation of parts and accessories can result in injury
or property damage. Read the owner’s operation manual carefully before using this
product. The owners operation manual provides important safety instructions and
warnings which should be followed closely. For any questions or concerns, please
contact Fujitsu General America, Inc. Proper sizing and installation of equipment is
critical to achieve optimal performance. Split system air conditioners and heat pumps
must be matched with appropriate coil components to meet ENERGY STAR criteria. Ask
your contractor for details or visit www.energystar.gov.
In most climates a heat pump will handle all of your heating needs. However, this
system sometimes requires some other additional source of heat to satisfy heating
requirements in the coldest environments. Almost all of Fujitsu’s heat pumps use
inverter technology and as such offer a wider operating range and more heat capacity
than a standard heat pump but will not provide adequate heating if improperly sized
or operated outside of its operating range. Specifications vary by model; please consult
your contractor before choosing a heat pump as your only source of heat.
Systems will maintain temperature up to +/-4 degrees relative to set temperature. To
increase energy efficiency on multi-type systems, you should turn off the evaporators
when heating or cooling is not needed.
DISCLAIMER
CERTIFICATIONS
L
Reverse cycle
heat pump
NOTE
Fujitsu’s products are subject to continuous improvements. Fujitsu reserves the right to
modify product design, specifications and information in this brochure without notice
and without incurring any obligations.
FUJITSU MODEL NOMENCLATURE
R
Note: Condensing units come pre-charged from factory. Additional refrigerant may be
required, be sure to check installation manual for more details.
THINGS TO KNOW BEFORE YOU INSTALL A FUJITSU SYSTEM
*18+18 is the only 2 indoor unit combination allowed for AOU36RLXFZ1 and requires kit K9FZ1818.
While these systems share indoor units, different line sizes are required.
^ Line set size from outdoor unit AOU48RLXFZ1 to the branch boxes.
1
Minimum combined pipe length from outdoor unit to branch box.
2
Minimum combined pipe length from branch box to indoor unit each.
18
Internet sales are strictly prohibited and unauthorized. Any HVAC systems purchased
on the Internet, from an online retailer or any similar e-tailing website, OR where the
original factory serial numbers of the display have been removed, defaced, or replaced
in any way WILL NOT BE COVERED BY WARRANTY.
•
Cooling capacity is based on the following conditions:
10-Year and 12-Year warranties exclude: R22 models, IAQ models, ASU30RLX,
ABU18RULX, ABU24RULX, ABU36RSLX, AUU18RLCX, AUU24RCLX, AUU36RCLX,
AUU42RCLX, AOU18RLX, AOU24RLX, AOU30RLX, AOU36RLX, AOU42RLX
While these systems share indoor units, different line sizes are required.
Model
NON-INTERNET RETAIL POLICY
7 Year Compressor / 5 Year Parts warranty.
z
Outdoor Unit
S=
X=
Z
Super
Efficient
Extended
Line Set
Z=
Zone
W=
Wall
Mount
Only
when followed by
) H=
F = HFI (a “W” or “Z”
or Floor Mount
High
H=
Heating
Wall Mount
W=
Only
Compact
C = Cassette or Slim
Duct
B=
230V
E=
Engineering
Series
H
High
Heating
H=
High
Heating
ISO
ASTM
ISO14001 is the standard defined by the International Organization
for Standardization (ISO) related to environmental management
systems. Fujitsu General America, Inc. has been acknowledged by
an internationally accredited compliance organization as having an
appropriate program of environmental protection procedures and
activities to meet the requirements of ISO14001. The air conditioners
manufactured by Fujitsu have received ISO9001 series certification for
quality assurance.
Our outdoor units shall withstand 1,000 hours of salt spray tested per procedure ASTM
B117.
ROHS COMPLIANT
• ISO9001
• ISO14001
AHRI ENERGY GUIDE® PROGRAM (U.S.)
To view AHRI numbers or Energy Guide labels, please go to www.ahridirectory.org.
Fujitsu participates in the RoHS Directive, which is the Restriction of Hazardous
Substances in electrical and electronic equipment. It is an
EU directive intended protect the environment by forcing
manufacturers to eliminate or severely curtail the use of
cadmium, hexavalent chromium, and lead in all products
from automobiles to consumer electronics.
HRAI ENERGUIDE® PROGRAM (CANADA)
Samples:
14.0 - 33.0
* 1, 2 or 3 at the end of a model number denotes a model revision. Please note models may not be combined with each other.
70
71
FEATURES
For over 40 years,
making the hottest places cool
and the coolest places...
more comfortable.
Halcyon Mini-Splits Are For You If:
zIf
you want to reduce your utility bills by up to 25%
zCentral
air quotes give you sticker shock
zYou
don’t want to lose space to ductwork
zYou
have warm or cold spots in your home or business
z
Your
window air conditioner’s noise prevents you from
hearing the television
Distributed by:
is worldwide trademark of FUJITSU GENERAL LIMITED and
is a registered trademark of Japan, the USA, and other countries or areas.
is worldwide trademark of FUJITSU GENERAL LIMITED.
Part #6-26-FG2028 Rev. 1/18
Fujitsu General America, Inc.
353 Route 46 West
Fairfield, NJ 07004
Toll Free: (888) 888-3424
Local: (973) 575-0380
Fax: (973) 836-0447
Email: hvac@fujitsugeneral.com
www.fujitsugeneral.com
A subsidiary of
Fujitsu General Limited
Download PDF