Mitsubishi | PEAD-A30AA5 | Catalogue | Mitsubishi PUYA12NHA6 Catalogue

Mitsubishi PUYA12NHA6 Catalogue
M-SERIES CONTRACTOR GUIDE
INTRODUCING MXZ-C H2i ®
MITSUBISHI ELECTRIC IS A WORLD
LEADER IN PRODUCTS THAT HELP
PEOPLE MAKE COMFORT PERSONAL
When it comes to providing personalized comfort in every room of every building, we are here to help.
No other company is as committed to creating environmentally friendly and affordable technology
that’s ideal for today’s home and work environments no matter the size or shape. With over 30 years
of industry leadership, we are proud to be America’s #1 selling brand of ductless technology.
QUALITY
Mitsubishi Electric is consistently recognized by HVAC contractors as the #1 preferred brand with the
highest quality rating among manufacturers. Our products provide extraordinary service life extending
years beyond the norm.
PERFORMANCE
We deliver a complete range of compact and powerful cooling and heating products that are also
intelligent, energy-efficient and quiet.
TRAINING
We provide comprehensive product and applications instruction through our regional training centers
across the United States.
SUPPORT
We offer national TV and digital campaigns, co-op and advertising assistance, social media exposure
and training, meSync apps for iPhone and iPad and the most experienced sales, engineering and
service professionals.
GROWTH
With nearly 20 years of consistent double-digit percentage growth, we continue to lead the market’s
growth acceleration. Our products and services provide opportunities for distributors and contractors
to enhance and grow their businesses.
TABLE OF CONTENTS
PRODUCT OVERVIEW ................................................................................................................................................ 4
PRODUCT FEATURES
H2i® Technology .................................................................................................................................................... 5
Energy Efficient ..................................................................................................................................................... 6
ENERGY STAR® Systems ..................................................................................................................................... 7
INVERTER Technology ........................................................................................................................................ 8
Healthier and Cleaner Air ................................................................................................................................... 9
Hand-held Wireless Comfort Control ........................................................................................................... 10
kumo cloud™ and i-see Sensor™ 3D ................................................................................................................ 11
Wall-mounted Wireless and Wireless Control .............................................................................................12
BEST PRACTICES ....................................................................................................................................................... 17
MULTI-ZONE PRODUCTS ........................................................................................................................................ 19
SINGLE-ZONE PRODUCTS ......................................................................................................................................23
M-SERIES ACCESSORIES ........................................................................................................................................25
M-SERIES PRODUCT SPECIFICATIONS ...............................................................................................................31
ADDITIONAL M-SERIES INFORMATION ..............................................................................................................52
PRODUCT OVERVIEW
Wall-mounted
Floor-mounted
Ceiling-recessed
Horizontal-ducted
Multi Position
Outdoor Unit
Features
Benefits
INVERTER-DRIVEN COMPRESSORS
Maximizes energy savings by using only the energy needed to
perfectly cool or heat an area
EASY INSTALLATION
Installs quickly and easily, without the need for major
construction and remodeling
COMPLETE ZONE CONTROL
ealizes maximum control and energy efficiency by cooling
R
and heating only those spaces in use
PERSONAL COMFORT CONTROL
Complete comfort control of temperature, fan speed, and air
direction in each room or zone
CLEANER AIR WITH WASHABLE,
ANTI-ALLERGEN FILTERS
Improves air quality and saves money
HYPER-HEATING INVERTER® (H2I® ) HEAT PUMPS
Provides instant warmth even in extreme climates
(down to -13° F)
ULTIMATE ENERGY EFFICIENCY
With higher SEER and HSPF ratings
4 / MITSUBISHI ELECTRIC / M-SERIES / SPECIFICATIONS
H2i MXZ HEATING CAPACITY
AT LOW TEMPERATURES*
T LOW TEMPERATURES*
HEAT AND LOTS OF IT
0
5
10
17
25
30
35
40
Outdoor Temperature Degrees FWB
% Heating Capacity
120
100%
93%
100
80
78%
60
76%
MXZ-C-NAHZ
40
Standard Heat Pump
20
47
0
-13
-4
0
5
10
17
25
30
35
40
47
Mitsubishi Electric Hyper-Heating INVERTER® systems feature the most advanced heat pump
Outdoor Temperature Degrees FWB
ion for defrost.
nt temperature conditions may
technology for delivering exceptional heating performance.
Single
and multi-zone systems
Includes
correction
for zone
defrost.
*
heater (MSZ-GE and MSZ-FE 1:1 systems)
NOTE: Low ambient temperature conditions may
give you year-round comfort control of one room to every
room
of(MSZ-GE
the home.
require base
pan heater
and MSZ-FE 1:1 systems)
MUZ-FH12NA H2i HEATING CAPACITY
MUZ-FH H2iATHEATING
CAPACITY
LOW TEMPERATURES*
120 AT LOW TEMPERATURES*
100
120
100%
93%
80
78%
60
76%
MXZ-C-NAHZ
Standard Heat Pump
40
20
0
-13
-4
0
5
10
17
25
30
35
Outdoor Temperature Degrees FWB
40
47
* Includes correction for defrost.
NOTE: Low ambient temperature conditions may
require base pan heater (MSZ-GE and MSZ-FE 1:1 systems)
% Heating Capacity
% Heating Capacity
120
100
80
60
40
% Heating Capacity
H2i MXZ HEATING CAPACITY
AT LOW TEMPERATURES*
78%
60%
80
60
40
0
-13
MUZ-FH
Standard Heat Pump
20
20
0
100%
100
-13
-4
0
5
80
60
40
20
0
HEATING
YEAR-ROUND
COMFORT
78%
Even when it's -13° F
outdoor ambient,
producing up to 100%
60%
heating capacity
at 5° F.
-13
-4
0
5
10
17
25
in extreme climates
without the need for
MUZ-FH
energy-consuming
Standard Heat Pump
indoor supplemental
30 heating
35
40devices.
47
require base pan heater (MSZ-GE and MSZ-FE 1:1 systems)
17
25
30
35
40
47
STANDARD HEAT PUMP HEATING
CAPACITY AT LOW TEMPERATURES*
120
HOT-START
100
TECHNOLOGY
80
MINIMAL
MAINTENANCE
provides warmth
from
60
the start, reducing drafts.
40
20
0
Outdoor Temperature Degrees FWB
Includes correction for defrost.
*NOTE:
Low ambient temperature conditions may
10
require base pan heater (MSZ-GE and MSZ-FE 1:1 systems)
% Heating Capacity
% Heating Capacity
100
100%
5
*
NOTE: Low ambient temperature conditions may
Includes correction for defrost.
*NOTE:
require base pan heater (MSZ-GE and MSZ-FE 1:1 systems)
Low ambient temperature conditions may
MUZ-FH H2i HEATING CAPACITY
AT LOW TEMPERATURES*
120
0
10
17 Temperature
25
30
35
40 FWB
47
Outdoor
Degrees
Outdoor
Temperature
Includes
correction
for defrost.Degrees FWB
-4
*
-13
-4
0
5
thanks to easily accessible
filters, little or no ductwork
to clean, and simple wiring
between the indoor and
outdoor
10
17
25units.
30
35
40
47
Outdoor Temperature Degrees FWB
Includes correction for defrost.
NOTE: Low ambient temperature conditions may
require
pan heater (MSZ-GE
and MSZ-FE 1:1 systems)
QUIETER THAN
Abase
HUMAN
WHISPER
Do you hear that? No? Mitsubishi Electric systems operate
at low sound levels. Our indoor units produce decibels barely
at a whisper level. Compare to other common sounds:
Ambulance siren
Circular saw
Vacuum cleaner
Normal conversation
Whisper
Our indoor units
120 decibels
110 decibels
80 decibels
60 decibels
30 decibels
19-34 decibels*
Did you hear that? We hope you did.
Source: National Institute for Occupational Safety and Health
*Smallest to largest capacity indoor unit at low speed
MITSUBISHI ELECTRIC / M-SERIES / SPECIFICATIONS / 5
ENERGY EFFICIENT AND ENVIRONMENTALLY FRIENDLY
M-Series systems utilize green technologies, and are much more efficient. Homeowners
never have to sacrifice comfort over worries about high-energy costs.
▶▶INVERTER-driven compressor technology results in substantial energy and utility savings
for homeowners.
▶▶Zone control for improved comfort and decreased energy usage.
▶▶Many ENERGY STAR ® certified systems.
▶▶SEER ratings as high as 33.1 – dramatically better than conventional systems.
▶▶Local and state utility rebates and incentive opportunities.
▶▶Environmentally friendly R410A refrigerant with zero Ozone Depletion Potential (ODP).
▶▶83% of system components are recyclable.
▶▶Washable filters made from natural materials.
Visit dsireusa.org for information on available local rebate
opportunities from state or utility companies.
Savings Opportunities
Mitsubishi Electric split-zoning, cooling-only and heat pump systems are so energy efficient
that a majority of our INVERTER-driven systems have received ENERGY STAR® certification.
This can mean big savings. Add in the federal tax credit and local government and utility
rebates, and you have an opportunity to enjoy comfort at substantial savings.
For details on qualifying systems, go to www.mitsubishicomfort.com/taxcredit, or visit
www.dsireusa.org for information on available local rebate opportunities from state
governments or utility companies.
6 / MITSUBISHI ELECTRIC / M-SERIES / SPECIFICATIONS
ENERGY STAR® CERTIFIED SYSTEMS
RESIDENTIAL AIR CONDITIONER
AHRI Reference #
Outdoor
Indoor
EER 95 F
SEER
HSPF
8715778
MUY-GL09NA-U1
MSY-GL09NA-U1
15.40
24.60
N/A
8715779
MUY-GL12NA-U1
MSY-GL12NA-U1
13.00
23.10
N/A
8715780
MUY-GL15NA-U1
MSY-GL15NA-U1
13.00
21.60
N/A
8715781
MUY-GL18NA-U1
MSY-GL18NA-U1
13.40
20.50
N/A
8715782
MUY-GL24NA-U1
MSY-GL24NA-U1
12.50
20.50
N/A
RESIDENTIAL HEAT PUMP
AHRI Reference #
Outdoor
Indoor
EER 95 F
SEER
HSPF
8797130
MUZ-FH06NA
MSZ-FH06NA
19.00
33.10
13.50
7002062
MUZ-FH09NA
MSZ-FH09NA
16.10
30.50
13.50
7002063
MUZ-FH12NA
MSZ-FH12NA
13.80
26.10
12.50
7002444
MUZ-FH15NA
MSZ-FH15NA
12.50
22.00
12.00
8797133
MUZ-FH18NA2
MSZ-FH18NA2
12.50
21.00
12.00
8856678
MUZ-GL09NA-U8
MSZ-GL09NA-U1
15.40
24.60
12.80
8715783
MUZ-GL12NA-U1
MSZ-GL12NA-U1
13.00
23.10
12.50
8715784
MUZ-GL15NA-U1
MSZ-GL15NA-U1
13.00
21.60
11.70
8715785
MUZ-GL18NA-U1
MSZ-GL18NA-U1
13.40
20.50
11.20
8715786
MUZ-GL24NA-U1
MSZ-GL24NA-U1
12.50
20.50
10.00
3837470
SUZ-KA18NA
SEZ-KD18NA
12.50
17.50
10.00
3837467
SUZ-KA12NA
SEZ-KD12NA
12.50
16.00
10.00
3837469
SUZ-KA15NA
SEZ-KD15NA
12.00
15.50
10.00
4415252
SUZ-KA12NA
SLZ-KA12NA
12.00
15.40
9.60
3837466
SUZ-KA09NA
SEZ-KD09NA
12.00
15.00
10.00
4415024
SUZ-KA09NA
SLZ-KA09NA
12.00
15.00
9.60
7505787
MXZ-3C24NA
Non-Ducted Indoor Units
13.60
20.00
9.80
7434482
MXZ-4C36NAHZ
Non-Ducted Indoor Units
14.00
19.10
11.30
7434477
MXZ-5C42NAHZ
Non-Ducted Indoor Units
13.40
19.00
11.00
7451969
MXZ-3C24NAHZ
Non-Ducted Indoor Units
13.50
19.00
10.00
7432927
MXZ-8C48NA
Non-Ducted Indoor Units
12.00
18.90
11.40
7432944
MXZ-8C48NAHZ
Non-Ducted Indoor Units
12.00
18.90
11.00
7451794
MXZ-3C30NAHZ
Non-Ducted Indoor Units
12.50
18.00
11.00
8063926
MXZ-3C24NA
Mixed Ducted and Non-ducted Indoor Units
12.40
18.00
9.50
3577580
MXZ-2B20NA
Non-Ducted Indoor Units
12.00
18.00
8.90
3589025
MXZ-2B20NA
Specific
12.50
18.00
8.90
3885922
MXZ-3B24NA
Non-Ducted Indoor Units
12.00
17.50
9.30
3896180
MXZ-3B24NA
Specific
12.50
17.50
9.30
3949963
MXZ-3B24NA
Specific
12.50
17.50
9.30
7434486
MXZ-4C36NAHZ
Mixed Ducted and Non-ducted Indoor Units
12.65
17.45
10.70
7434481
MXZ-5C42NAHZ
Mixed Ducted and Non-ducted Indoor Units
12.10
17.00
10.55
7451974
MXZ-2C20NAHZ
Non-Ducted Indoor Units
13.50
17.00
9.80
8111731
MXZ-2C20NAHZ
Mixed Ducted and Non-ducted Indoor Units
12.25
16.00
9.65
8111731
MXZ-2C20NAHZ
Mixed Ducted and Non-ducted Indoor Units
12.25
16.00
9.65
Note: List is current as of this printing.
MITSUBISHI ELECTRIC / M-SERIES / SPECIFICATIONS / 7
PUT COMFORT ON CRUISE CONTROL
INVERTER System
Automatically adjusts instantly
for consistent comfort
Set Temperature
INVERTER TECHNOLOGY
72°
Conventional System
Constantly fluctuates, wasting
energy and causing drafts
Time
Sophisticated, electronic control systems detect any change in zone temperature
and—like a car’s cruise control—automatically adjust the speed of the outdoor unit's
INVERTER-driven compressor for precise capacity and temperature control.
Electronic LEVs exactly control refrigerant flow to regulate coil temperature.
8 / MITSUBISHI ELECTRIC / M-SERIES / SPECIFICATIONS
MULTIPLE FILTERS FOR CLEANER, HEALTHIER AIR
Our indoor units use a sophisticated multi-part filtration system to reduce contaminants such
as allergens, viruses and bacteria from the air. This combination of filters provides a healthier,
breathing environment for the home.
1
NANO PLATINUM FILTER:
• Ceramic and platinum nanoparticles are
incorporated into the filter material to provide
antibacterial and deodorizing characteristics
to improve air quality.
2
DEODORIZING FILTER:
AVAILABLE ON MSZ-FH
eatures a ceramic surface absorption element
F
and uses nanotechnology for
high-power odor absorption.
1
• Periodic cleaning, following the
recommended procedures, will maintain filter
effectiveness.
2
3
3
ELECTROSTATIC ANTI-ALLERGY
ENZYME FILTER:
AVAILABLE ON MSZ-FH09/12/15NA AND MSY/Z-GE06/09/12/15/18
• Reduces germs, bacteria and viruses.
• H
elps trap dust, pollens, mites and other particles.
• Utilizes an enzyme catalyst to help break down the sulfur atom bonds
in allergen proteins, transforming them into non-allergen proteins, and,
effectively cleaning the air (filter should be cleaned regularly to maintain
effectiveness).
MITSUBISHI ELECTRIC / M-SERIES / SPECIFICATIONS / 9
HAND-HELD COMFORT CONTROL
Mitsubishi Electric hand-held controllers can adjust temperature, fan speed, and more.
Operation Select (Heat, Cool, Auto, Dry)
Fan Speed
Timer
Econo Cool
Vane Control
HR/MIN (Time Set)
Smart Set Button
Clock Set
Reset
Sliding Cover
CONTROLLER FEATURES INCLUDE:
▶▶MODE: HEAT, COOL, AUTO, and DRY.
▶▶FAN: Adjusts fan speed.
▶▶STOP/START: A 12-hour ON/OFF timer .
▶▶ECONO COOL: Energy efficient cooling option.
▶▶VANE: Sets horizontal vane position.
▶▶TIME: Power off timer and clock adjustment.
▶▶SMART SET: Programs multiple settings into one
quick-press feature. Programs heating set back.
Included with M-Series wall-mounted and floor-mounted systems.
Optional wall-mounted wireless full functional (MHK1) and wall-mounted
wired controllers are available (PAR-32MAA & PAC-YT53CRAU requires
MAC-333IF-E interface for MSZ/Y and MFZ indoor units).
10 / MITSUBISHI ELECTRIC / M-SERIES / SPECIFICATIONS
Additional features available on certain models:
• "Powerful Mode" function permits system to temporarily run
at a lower/higher temperature with an increased fan speed,
which quickly brings the room to the optimum comfort level
• Wide Vane setting provides a wider Whorizontal air distribution
on select models with wider cabinets
Features are determined by the indoor unit selected. Not all
features are on all controllers or indoor units.
KUMO CLOUD™
kumo cloud is a cloud service hosted by Mitsubishi Electric Cooling & Heating to remotely
or locally control your Mitsubishi Electric indoor units. This is achievable by installing the wireless Interface
(PAC-WHS01WF-E) in each indoor unit. The interface requires a wireless router that has WPS (Wireless
Protected Setup) feature as well as Internet access. kumo cloud app can monitor, control, and schedule
multiple indoor units in multiple locations across Apple, Android, and Amazon Fire devices.
Specifications and requirements
• Allows Mitsubishi Electric indoor unit to be controlled
remotely or locally with the kumo cloud™ app and
web service.
• Available in:
• A Mitsubishi Electric Wireless Interface (PACWHS01WF-E) installed by a professional contractor.
• Smart Phone with kumo cloud (app required).
- Apple App Store iOS® 8.0 and newer.
Wireless Interface
- Google Play Android™ 4.0 and newer.
Enable remote access and control over your
MitsubishiElectric M- & P-Series systems with the
Wi-Fi Interface and kumo cloud app. The Wireless
Interface is an integral part of the kumo cloud
solution, allowing a Mitsubishi Electric indoor unit
to communicate with the web-based app and web
service. Through a wireless connection over the local
network, the Wireless Interface establishes a remote
connection with the cloud and provides remote control
and management of your system.
- Amazon Apps 4.1 and newer.
• Web access at kumocloud.com.
• Availability to group units together.
• Organize groups into sites.
• Batch command units.
• Program in events to schedule the units.
• Available in Fahrenheit or Celcius.
• Error and Filter popup.
• Manual setup to add units.
• Must have a wireless router with WPS capability.
• Internet access is required for initial setup and
scheduling.
MITSUBISHI ELECTRIC / M-SERIES / SPECIFICATIONS / 11
MHK1 WIRELESS REMOTE CONTROLLER KIT
Includes Wireless Wall-mounted Remote Controller, Wireless Receiver and Cable.
Portable Central Controller and Outside Air Sensor are optional accessories.
Wireless Wall-mounted Remote
Controller and Wireless Receiver
• Installs anywhere with simple wall-mounted design.
• Large, backlit, easy-to-read display.
• Dual set-point control with system changeover.
• Both controller and receiver enabled with
RedLINK™ reliability.
The basic MHK1 Wireless Remote Controller Kit
includes a Wireless Wall-mounted Remote Controller
and a Wireless Receiver located with the indoor wallor ceiling-mounted unit. You may choose to enhance
your control convenience and flexibility with an optional
Portable Central Controller, Outside Air Sensor and the
new RedLINK™ Internet Gateway.
MHK1 FEATURES
FUNCTION
DESCRIPTION
ON/OFF
On/Off operation for a single indoor unit
Operation Mode
Cool / Drying / Auto / Heat / Fan operation modes dependent on connected system
Temperature Setting
Set temperature from 40° F - 99° F depending on operation mode and connected system
System Changeover Deadband Value
2° F - 8° F
Schedule Operation
5-2, 5-1-1
Optimal Start
Eliminates the guesswork when setting your schedule. Allows the remote controller to “learn"
how long your split-zoning system takes to reach programmed temperature setting, so the
temperature is reached at the time you set
Fan Speed Setting
Hi/Mid-2/Mid-1/Low/Auto Available fan speed settings dependent on connected system
Airflow Direction Setting
Airflow angles: 100° - 80° - 60° - 40° and oscillate available airflow direction settings dependent
on connected system
Permit/Prohibit Function
Individual prohibit operations for each remote controller function (ON/OFF, Set Temperature
and Operation Mode)
Space Temperature
Displays the measured space temperature
Error Indication
Displays error code
Display Outside Temperature and Humidity
Requires optional MOS1 Outside Air Sensor
Dimensions - (W x D x H)
Remote Controller: 5-3/16" x 1-1/2" x 3-9/16" Receiver: 3-1/4" x 1-5/16" x 6-7/16"
Operating Ambient Temperature
Remote Controller: 32° F – 120° F Receiver: -40° F – 165° F
Operating Ambient Humidity
Remote Controller: 5% - 90% RH (non-condensing) Receiver: 5% - 90% RH (non-condensing)
Power Supply
2 AA batteries (included)
Note: MHK1 Compatible with current INVERTER-driven M-Series as noted in data charts.
12 / MITSUBISHI ELECTRIC / M-SERIES / SPECIFICATIONS
Optional MCCH1 Portable
Central Controller
Optional MOS1 Outside
Air Sensor
• Control up to 16 RedLINK™ devices.
• Monitors outside air temperature
and humidity.
• Requires MHK1 per indoor unit.
• Monitor and control On/Off, Mode
and Set Temperature.
• Schedule override capability.
• Displays on MHK1 Remote
Controller and MCCH1 Portable
Central Controller.
• Does not interfere with other
wireless devices.
• Displays outside air temperature and
humidity when used with MOS1 Outside Air Sensor.
OPTIONAL PAC-US444CN-1 THERMOSTAT INTERFACE
Our Thermostat Interface allows HVAC thermostats or input/output
controllers to control Mitsubishi Electric Cooling & Heating indoor
units through our CN105 connector. Any indoor unit that can be
controlled by an MHK1 can now be controlled by a third party
HVAC thermostat or input/output controller.
This allows Mitsubishi Electric systems to take advantage of the
capabilities of third party thermostats including but not limited
to: geo fencing, automatic scheduling, humidity control, weather
forecasting and more.
Our patent-pending algorithm allows the outdoor unit's INVERTER-driven compressor to vary its capacity for
greater energy savings. The preferred system setup is to use a conventional system control with two stages of
cooling and heating (W1, W2, Y1, and Y2) to provide personal comfort and energy savings. The interface can
also be setup to accept only one stage of cooling and heating (W1 and Y1).
The Mitsubishi Electric Thermostat Interface also allows for fan speed control. Third party thermostats or input/
output controllers can control the indoor unit's fan speed to three different levels: high, medium, and low.
Specifications
• Allows an HVAC Thermostat or I/O Controller to
control a Mitsubishi Electric Cooling & Heating
[M-Series or P-Series] indoor unit.
• One Thermostat Interface required per indoor unit.
• Indoor unit modes available: Cool, Heat, Fan, and
Off.
• Provides 3 input terminals to control fan speed
control: High, Medium, and Low.
• No addressing required.
• Connection: CN105 – Active IT Terminal.
• Dimensions: (H x W x D) 3.96 in x 3.17 in x 0.93 in.
• Thermostats Tested:
- Nest®
- Honeywell® Lyric™
- INNCOM® by Honeywell® with High and Low
fan speed control.
• Terminal Block: 20-30 VAC Rated.
• Required: Active CN105 on Mitsubishi Electric
indoor unit control board.
• Required: HVAC Thermostat or I/O Controller (field
supplied).
• Required: 24VAC transformer needed (field
supplied).
MITSUBISHI ELECTRIC / M-SERIES / SPECIFICATIONS / 13
Advanced Features
M- and P-SERIES
• Conventional 2H/2C system operation (preferred).
• Delayed off adjustable setting.
• Conventional 1H/1C system operation.
• Static pressure adjustable setting.
• CN24 operation during defrost.
Model:
• Auto recovery after power failure.
PAR-31MAA
• Thermostat detects room temperature.
• Fan speed during thermal off heating mode.
• Transformer (VPL24-210).
Job Name:• Two-stage heat and cool thermostat operation.Location:
Date:
Purchaser:
Engineer:
Submitted to:
For
2. Local
remote
System
Designation:
Reference
Approval
controller
Schedule No.:
PAR-32MAA
BACKLIT
MA
REMOTE
CONTROLLER
2-1. MA remote controller [PAR-31MAA]
Construction
A3 Rev.
Controller
2. Local remote controller
BACKLIT MA
REMOTE CONTROLLER
(PAR-31MAA)
• Wiring: connects
• Room Temperature:
Displays
using twoSPECIFICATIONS
:Not available
:Each group
2.
Schedule
and
timer
setting
room temperature
sensed
either
wire,
stranded,
non-polar
• ControlsItem
group operation for up to
16 indoor units in a singleSetting
groupDisplay
Description
at the indoor
unitTimer
(default)
or
atmulti-lingualcontrol
wire to
indoorand
unit
• Features
selectable
LCD (English,
Spanish,
ON/OFF timer
French)
Turns ON and OFF daily
at a set time.
the remote controller.
connection
terminal
or
control
• Time can beand
set inCelsius
5-minute increments.
• Supports both Fahrenheit
• It is also possible to set
the ON time (MAC-333IF
only or the OFF time only.
adapter
for
•
User
functions
allow
user
to
set
• Set Temperature Range Limit:
Auto-OFF timer
Turns off the unit after M-Series)
a certain period of operation.
requires crossover
- On/Off
From the Backlit
MA
Controller,
Operation time can be set to a value from 30 to 240 minutes in
- Operation modes• 10-minute
cool, heat,
dry,
fan for indoor unit grouping.
increments.
wiring
the allowable set temperature
Fri
Room
Cool
Set temp.
Mode
Temp.
Auto
- Set temperature
Fan
Weekly timer
Weekly ON/OFF times and set temperatures can be set.
speed for
setting
range can be- Fan
reduced
cool
•5-minute
Dimensions:
x 3/4 x 4-3/4"
• Time can be set in
increments. Up to4-3/4
8 schedule
- Airflow direction patterns can be set per day of the week.
and heat modes.
(120
x
19
* Not valid when the ON/OFF
timer
is set.x 120 mm).
• Timer Operation:
Night setback
The temperature range and the start/stop
- Weekly
Timer: On/Off/Temperature
settingtimes
up can
to be
8 set.
times pertoday
of
• Function Lock
Out:
Prohibits
• Requires
MAC-333IF-E
use
the week in 1-minute increments
all functions -orSimple
all functions
M-Series.
Timer: On and
Off time with
can be
set once within
72-hour
:Not available
:Each
group
3. Restriction
settings
period
1-hour
increments
except On/Off
frominItem
the
backlit
Description screen for 3D i-see
Setting Display
•
Setting
- Auto-off
Timer: Turns indoor unit Off based on countdown time up
Allows/disallows The following operation can be prohibited by making certain
MA controller.
sensor, draft reduction mode.
to 4-hours
in 30-minute
settings on increments
the centralized controller: ON/OFF, operation mode
local operation
setting, temperature setting, and filter sign reset.
• Room Temperature:
Displays room temperature sensed either at the
* While an operation is prohibited, the operation icon lights up
:Not available
:Each group
indoor unit (default)
oronatthethe
controller
(only
Mainremote
display in the
"Full" mode).
Description
Setting Display • Set Temperature Range Limit: From the Backlit MA Controller, the
Operation lock
The following operation can be prohibited respectively: ON/OFF,
Switches between ON and OFF.
allowable set temperature
can be setting,
reduced
for direction
cool and heat
operation moderange
setting, temperature
and airflow
setting.
modes
Switches among Cool/Dry/Fan/Auto/Heat.
• Special
FunctionThe
Rotation/Backup
formode
P-Series)
room temperature range(Lead/Lag
for each operation
can be
Temperature
restricted.
restriction
The temperature can be set within the following range.
• SEZrange
Static
Pressure
Setting
Cool/Dry : 19°C - 30°C (14°C - 30°C) / 67°F - 87°F (57°F - 87°F)
• Supplemental
heat
The function
units operate enable/disable
at the preset temperature after a designated
Auto return
Heat
: 17°C - 28°C (17°C - 28°C) / 63°F - 83°F (63°F - 83°F)
period. function
• Set P-Series twinning
Auto
: 19°C - 28°C (17°C - 28°C) / 67°F - 83°F (63°F - 83°F)
(Time can be set to a value from 30 to 120 in 10-minute
( ) For PEFY/PFFY by setting DipSW 7-1 to ON and limits to NI6H fan speed only.
• Function Lock Out:
Prohibits all functions or all functions except
increments.)
Changes fan speed.
* Not validMA
when controller
the temperature setting range is restricted.
On/Off from the backlit
* Available fan speeds vary depending
on the model. group operation for up to 16 indoor units in a single group
Controls
• Addressing:
required
Administrator password
(required for schedule setting etc.) and
password No addressing
Changes airflow direction.
password (required
for test run
and function setting
• Wiring: connectsMaintenance
using two-wire,
stranded,
non-polar
control wire to
* Available airflow directions vary depending on the model.
etc.) can be set.
• Set temperature range limit:
Simple
MA allowable
setortemperature
range
can for
indoor
unit connection
terminal
control adapter
(MAC-333IF
Switches between louver ON/OFF.
M-Series)
requires
crossover
wiring
for
indoor
unit
grouping
be
reduced
for
cool
and
heat
modes.
:Not available
Interlocked setting and interlocked operation setting with the
:Each group
4. Miscellaneous items
• Dimensions: 4-3/4 x 3/4 x 4-3/4" (120 x 19 x 120 mm)
City Multi LOSSNAY units can be made.
Functions
1. Operation/Display
Item
ON/OFF
Operation mode
switching
Room temp.
setting *3
PAC-YT53CRAU SIMPLE MA CONTROLLER
Fan speed
setting
Air flow direction
setting
Louver setting
Ventilation
equipment
control
Auto descending
panel *1
Notes:
backlight
Main display
mode setting
Clock *2
Clock display
Item
• Room temperature can be sensed
eitherSelect
at the
indoorDescription
unit (default) or at the
the display language from the following 8 languages.
Language
English,
French,
German,
Spanish,
Italian,Portuguese, Swedish,
Selection
remote
controller.
Raises and lowers the automatic elevating panel.
The Stop/Low/High settings of the ventilation equipment can
be controlled.
Setting Display
and Russian
Contrast
Adjusts
LCD contrast.
• Grouping: Same group use only
with other
PAC-YT53CRAU
Simple MA Controllers,
Fixes the
vane position
for each air outlet.
PAR-32MAA
Backlit
MA
Remote
and
PAR-FL/A32MA
Wireless MA ManualController,
The Main display can be displayed in two different modes:
vane Angle *1
"Full" and "Basic."
Remote Controllers with up to two*1remote
controllers
per
group.
Contains Test run, Function setting, Refrigerant volume check,
Pressing any button turns the backlight on and it will stay lit
for a certain period of time depending on the screen.
Date (year/month/day) and time (hour/minute) can be set.
The set time as well as the day of the week will be displayed
on the Main display.
It is also possible to set not to display the time on the Main display.
Service
Refrigerant leak check, Smooth maintenance, Request code, and
• Wiring: Uses two-wire, stranded, non-polar
control wire for connecting TB15 Error history.
*1 This function
is active
only for the units
that support thewiring
function. for grouping
connection terminal on the indoor
unit.
Requires
crossover
*2 The clock is accurate within 50 seconds per month (at the temperature of 25ºC [77°F]). The clock is
The clock can be displayed in 12-hour format (AM/PM before
backed
up
for
7
days.
across indoor units.
or after the time) and 24-hour format.
*3 Temperature will be displayed either in Centigrade in 0.5- or 1-degree increments, or in Fahrenheit,
Room temp.
display *3
Error information
depending on the indoor unit model and the display mode setting on the remote controller.
• Dimensions: 2-3/4 x 9/16 x 4-3/4"
(70 x 14.5 x 120mm).
System example
When an error occurs, an error code and the unit address
• Requires MAC-333IF-E to use with M-Series.
appear.
Displays the room temperature on the Main display in the
"Full" mode during operation.
Air conditioning unit model, serial number, and contact
number can be set to appear when an error occurs. (The
information above needs to be entered in advance.)
* An error code may not appear depending on the error.
Filter information
A filter sign will appear when it is time to clean the filter.
Backlit LCD
14 / MITSUBISHI ELECTRIC / M-SERIES
Can be set
and shown by 0.5°C degree.
/ SPECIFICATIONS
Non-polarized
Non-polarized
2-wire
MAC-333IF-E SYSTEM CONTROL INTERFACE
• Allows M-Series indoor units to communicate with the CITY MULTI Controls Network via M-Net.
• Provides an input to allow remote On/Off control of indoor unit (3-Wire plug adapter included).
• Allows the M-Series indoor units to connect to MHK1 Wall-Mounted Wireless Remote Controller
when using other MAC-333IF-E functions. (Note: External 12VDC power supply is required when
adding the MHK1 to the MAC-333IF-E).
• Allows the M-Series indoor units to connect to a MA remote controller.
• Power: 12V DC (supplied from indoor unit).
• Indoor unit connecting cable: Dedicated 5-wire cable included.
OPTIONAL REDLINK INTERNET GATEWAY
(AVAILABLE THROUGH SELECT DISTRIBUTORS)
• Connects any RedLINK Comfort System to the Internet to provide remote access
from PC, smartphone or tablet.
• No monthly fee, free app download.
• Remotely monitor and control your cooling and heating system, at any time, from
any place.
• View/change system settings and access multiple systems/zones.
• Provides over 90° temperature/comfort alerts through a dedicated website.
• Upgrades automatically as new features become available.
TM
MITSUBISHI ELECTRIC / M-SERIES / SPECIFICATIONS / 15
DETECT AND CONTROL TEMPERATURE FLUCTUATIONS
All M-Series systems detect room temperature fluctuations and automatically adjust
performance for ultimate comfort in any room.
▶▶All indoor models feature a return air sensor that constantly monitors and maintains
room temperature.
▶▶Continuous fan operation ensures temperature consistency.
▶▶Systems with and i-see Sensor™ 3D scan the room looking for humans with a particular
heat signature. The i-see feature senses floor temperature and delivers conditioned air to
those areas by double-vane airflow. (MSZ-FH09/12/15NA models).
▶▶Auto changeover feature automatically switches between cooling and heating modes
as needed to maintain a consistent temperature—just set it and forget it (MUZ and SUZ
outdoor units).
▶▶Seven horizontal airflow directions provide 150° of lateral airflow for greater conditioned
air circulation (wide vane or swing mode, available on the MSZ-FH09/12/15, MSZ/Y-GE24
and MSZ/Y-D30/36NA).
TM
Detects human locations
and temperature variations
and controls the airflow for
ultimate comfort
This amazing technology constantly monitors and adjusts
temperatures for maximum comfort and efficiency.
• Measures infrared radiation generated from surrounding
walls and surface angles
• Efficiently adjusts temperatures to ideal comfort levels
for occupants
16 / MITSUBISHI ELECTRIC / M-SERIES / SPECIFICATIONS
INSTALLATION BEST PRACTICES
Look for opportunities to use Mitsubishi Electric systems on every job!
Single and Multi-zone systems for Hot and Cold Spots, Living Rooms, Bedrooms, Kitchens, Allergy
Problems, Renovations, Energy Savings Opportunities, Media Rooms, Basements, Combination with
Traditional System, Whole Floor, Whole Home, New Homes…and more!
Properly installed systems heat and cool homes for a fraction of the cost of traditional systems.
By following installation best practices and providing homeowner education, you will help to insure customer
satisfaction, and increase referrals and sales. Visit a Mitsubishi Electric 2-day training course for more
information. Ask your Mitsubishi Electric distributor for details.
Outdoor Unit (Compressor)
Condensate Drain
• Set the unit on a stable, level surface.
• Use adjustment risers to prevent debris and snow
build-up and allow better drainage.
• Must slope downhill and can be routed with line
set and run to a suitable termination point, away
from crawl spaces and walkways.
• Secure outdoor units to the pad, risers and/or
surface using bolts and/or adhesives.
Cold Climate Recommendations
Line Set Insulation and Protection
• Use a pan heater to avoid defrost discharge
freezing inside the compressor.
• Insulation must cover entire line set length to
avoid condensation and decreased efficiency.
• Increase clearance under the outdoor unit to
promote easy drainage and reduce snow and
ice buildup.
• Once insulated, protect the outdoor portion of
the line set with Line Hide to avoid premature
insulation damage.
• Consider wall-mount brackets to maximize
outdoor unit clearance.
• Add UV tape as needed on areas without Line
Hide to ensure entire length is protected.
Tools
• Ratchet Flaring Tool
Refrigerant Charge
• Programmable Refrigerant Charging Scale
• Adjust refrigerant charge ONLY IF NECESSARY;
most installations do not require adjustments.
• Torque Wrench
• R410A Gauge and Hose Set
• Gauges are not needed to verify refrigerant levels.
Only if adjustments are necessary, be sure to use
a scale when adding/removing refrigerant.
Installation Tips for Maximum Efficiency—Indoors
• For homes with electric furnaces, consider shutting off the furnace at the breaker or set back
the furnace thermostat so that it does not compete with the Mitsubishi Electric system.
• For homes with zonal electric heat, consider shutting off the heaters at the breaker or set back
the zonal heater thermostats so they do not compete with the Mitsubishi Electric system.
• For temperature set back, set programmable thermostat to HEAT with the fan in ON position
for air distribution and setting the temperature 4° F below the Mitsubishi Electric system.
MITSUBISHI ELECTRIC / M-SERIES / SPECIFICATIONS / 17
Homeowner Education
Educate homeowners about their Mitsubishi Electric system to reduce callbacks and generate referrals:
• Use the Mitsubishi Electric system as the primary heating and cooling system to maximize benefits,
maintain comfort and ensure that the unit performs most efficiently.
• Secondary heating and cooling systems should remain off until your comfort is compromised. If your
comfort is compromised, supplement with your secondary system until your comfort requirements
are met.
• In extremely cold weather, you can temporarily:
»» Increase the temperature setting of the Mitsubishi Electric system.
»» Increase the fan speed.
»» Close doors to unoccupied portions of the house; and/or
»» Increase the thermostat setting on secondary heating systems as needed.
• Cleaning the filters several times a year optimizes the performance of the Mitsubishi Electric system.
Monthly cleaning is ideal for systems that are used regularly.
For technical information including submittals, parts, installation, service and more please
visit www.mylinkdrive.com
18 / MITSUBISHI ELECTRIC / M-SERIES / SPECIFICATIONS
MULTI-ZONE PRODUCTS
M-SERIES MULTI-ZONE PRODUCTS AND FEATURES
Total zone control: individually controlled rooms (up to 8) with a single outdoor system.
With the MXZ-C multi-zone standard and H2i® systems your customers can enjoy ideal levels of comfort
in the rooms you use most while reducing their energy costs. Each zone operates independently.
People in different rooms –like the kitchen, master bedroom or living room – can set temperatures for
personalized comfort.
THE MULTI-ZONE SYSTEM FEATURES INCLUDE:
• Mix and match flexibility of indoor unit styles and
combinations.
• A wide range of indoor unit capacities that match
the room size and requirements.
MXZ-2C20
MXZ-3C24
MXZ-3C30
MXZ-4C36
MXZ-5C42
MXZ-8C48
• Flexible options to tackle the most challenging
multi-room installations.
• High efficiency, multiple ENERGY STAR®
combinations.
• Hyper-Heating INVERTER® models available for
colder climate applications.
• Simple, quick, and cost-effective installation.
• Four-ton outdoor unit can support up to eight
indoor units using branch boxes.
• Advanced microprocessor control.
• Auto restart following a power outage.
• Self-check function offering integrated diagnostics.
• Wired and wireless control options.
WALL-MOUNTED INDOOR UNITS FOR
MULTI-ZONE SYSTEMS
Cooling and Heating
Slim, wall-mounted units provide enhanced, industry-leading
performance for the single-zone ductless product category.
MSZ-GL Heat Pumps l 06, 09, 12, 15, 18, 24
• Washable long life filters.
• 24 hour timer.
• Auto restart and auto cooling/heating changeover.
• Multiple fan speeds: 5 speeds (GL06 - GL18) and 4
speeds (GL24 only).
• Vertical air swing on all units.
- Horizontal swing on GL18 and GL24 only
- Wide airflow on GL24 only.
• All models ENERGY STAR® qualified.
• Compatible with kumo cloud™ control app and
Thermostat Interface.
• Wireless hand-held controller.
MITSUBISHI ELECTRIC / M-SERIES / SPECIFICATIONS / 19
WALL-MOUNTED INDOOR UNITS FOR MULTI-ZONE SYSTEMS (CONT'D)
MSZ-FH High Efficiency Heat Pumps | 06, 09, 12, 15, 18
• Industry-leading efficiency of 33.1 SEER (MSZ-FH06NA) and 30.5 SEER (MSZ-
FH09NA).
• Hyper-heating performance down to -13° F outdoor ambient. (use the degree symbol)
• 100% heating capacity at 5° F outdoor ambient. (use degree symbol)
• Triple-action filtration including anti-allergen enzyme filter.
• Double-vane air delivery for enhanced circulation.
• i-see SensorTM (superscript the TM) 3D senses human heat signatures.
• NEW multi-function wireless controller.
• Optional Thermostat Interface (PAC-US444CN-1) to allow for operation with thirdparty thermostats.
• Compatible with Mitsubishi Electric kumo cloud™ programmable thermostat app
(PAC-WHS01WF-E).
FLOOR-MOUNTED INDOOR UNITS FOR MULTI-ZONE SYSTEMS
Floor-mounted indoor unit mounts on the floor or up to 5" above floor and has front panel
access to the filter for ease of cleaning. It is perfect for difficult areas that may be smaller
or don’t have usable space on the walls.
MFZ Heat Pumps | 09, 12, 18
• T op and bottom discharge vanes.
• Hot-start technology.
• Quiet operation.
• Wireless remote control with smart set feature.
CEILING-RECESSED INDOOR UNITS FOR MULTI-ZONE SYSTEMS
SLZ 2'x2' ceiling-recessed cassette units offer a wide airflow pattern for better air
distribution in a less obtrusive style. Install SLZ in a hard ceiling (with an access panel
for servicing) or in 2'x2' drop ceiling.
SLZ Heat Pumps | 09, 12, 15
• Ventilation air knockouts.
• Built-in condensate lift mechanism (up to 20").
• Multiple airflow settings.
HORIZONTAL-DUCTED HEAT PUMPS FOR MULTI-ZONE SYSTEMS
SEZ ducted units provide comfort and efficiency while staying hidden either in the
ceiling or beneath the floor.
SEZ Heat Pumps | 09, 12, 15, 18
• Built-in condensate lift mechanism (up to 21-11-16").
• Static capability up to 0.20" WG.
• Optional filter box with MERV-8 filters.
Note: Select PLA, PCA, PEAD models are also compatible with select multi-zone MXZ-C systems.
For full MXZ-C combinations list, visit www.mitsubishipro.com/multizone
20 / MITSUBISHI ELECTRIC / M-SERIES / SPECIFICATIONS
MULTI-ZONE SYSTEM POSSIBILITIES
For a complete list of the MXZ-C Series approved combinations,
visit www.mitsubishipro.com/multizone
MULTI-POSITION DUCTED UNIT FOR MULTI-ZONE SYSTEMS
• Performance: One inch foam R4.2, fiberglass free insulation
reduces condensation and boosts efficiency.
• Quality: durable, powder coated cabinet.
• Serviceability: easily removable fan provides access for coil
cleaning.
• Flexibility: true multi-position, requiring no additional kits for
downflow configuration.
• Installation: quality construction with disassembly in mind to
make fitting through tight access points simple.
MVZ-A12AA4
MVZ-A18AA4
MVZ-A24AA4
MVZ-A30AA4
MVZ-A36AA4
• Comfort: DC motor ensures quiet and efficient operation year
round.
• Low Impact: Fully RoHS compliant to reduce carbon footprint.
• Air Quality: Positively pressurized cabinet and tested air leakage
less than 1%.
MXZ-5C42NA (2:1, 3:1, 4:1, 5.1) Outdoor Unit*
MFZ-KA09NA
Indoor Unit
MSZ-GL09NA
Indoor Unit
SLZ-KA 2'x2'
Cassette Unit
MSZ-GL09NA
Indoor Unit
SEZ-KD12NA
Indoor Unit
MXZ-8C48NA-R1 (2:1, 8:1) Outdoor Unit*
Branch Box
(Minimum of
one required
with MXZ-8B)
MVZ-A18AA4
Two MSZ-GL06NA
Indoor Units
SEZ-KD09NA Indoor Unit
MFZ-KA12NA Indoor Unit
*Illustration purposes only.
Minimum of two Indoor Units must be connected to all MXZ-C Outdoor Units. Minimum installed capacity cannot be less than 12,000 Btu/h.
MITSUBISHI ELECTRIC / M-SERIES / SPECIFICATIONS / 21
MULTI-ZONE SYSTEM POSSIBILITIES
For a complete list of the MXZ-C
Series approved combinations, visit
www.mitsubishipro.com/multizone
MXZ AND INDOOR UNIT COMPATIBILITY CHART
MULTI-ZONE
OUTDOOR UNIT
HYPER-HEATING EQUIPMENT
MXZ-2C20NAHZ
MXZ-3C24NAHZ
MXZ-3C30NAHZ
MXZ-4C36NAHZ
MXZ-5C42NAHZ
MXZ-8C48NAHZ
STANDARD EQUIPMENT
MXZ-2B20NA-1
MXZ-3C24NA
MXZ-3C30NA
MXZ-4C36NA
MXZ-5C42NA
MXZ-8C48NA
BRANCH
BOX
—
—
—
INDOOR UNIT
MVZ
12
MSZ-GL
6,9,12,15
ü
12,18
18, 24
ü
24,30,36
û
12,18,24
ü
30,36
û
MFZ-KA
ü
û
6,9,12,15,18
18
ü
24
6,9,12,15,18
24
9,12
ü
û
ü
û
ü
MSZ-FH
6,9,12,15
18
û
ü
ü
SEZ-KD
ü
9,12,15
18
û
ü
SLZ
9,12
15
ü
û
ü
ü
ü
ü
ü
PCA
û
24
PEAD
û
û
18
û
ü
12,24,30,36,42
ü
30,36,42
PLA
18,24
û
ü
12,30,36
ü
ü
ü
ü
ü
ü
û
12,18,24,30,36
ü
ü
ü
ü
ü
ü
ü
û
12,18,24,30,36
ü
ü
ü
ü
ü
ü
ü
û
12,18,24,30,36
—
û
û
9,12,15
ü
ü
—
—
—
—
ü
12,18
6,9,12,15
18, 24
ü
24,30,36
û
12,18,24
ü
30,36
û
12,18,24
30,36
û
12,18,24
30,36
ü
ü
ü
û
ü
û
6,9,12,15,18
24
18
ü
û
ü
24
û
ü
ü
û
ü
ü
ü
6,9,12,15,18
9,12
ü
ü
ü
ü
ü
ü
ü
ü
18
û
ü
ü
ü
ü
ü
9,12
15
ü
û
ü
ü
ü
ü
ü
42
42
û
24
24
18
24
û
û
û
û
û
ü
û
û
û
û
ü
û
ü
30,36,42
û
24,30,36
ü
42
nformation is current as of this printing. Minimum installed capacity cannot be less than 12,000 Btu/h.
PLA-A12BA can NOT be connected with MXZ-C models only. MVZ is compatible with MXZ-C models only and only 1 MVZ maybe used on any system. When an MVZ is
connected, total connected capacity must be 100% or less, and no P-Series indoor units can be used (PCA, PLA, or PEAD).
22 / MITSUBISHI ELECTRIC / M-SERIES / SPECIFICATIONS
û
ü
30,36,42
24
12,18,24,30,36
ü
30,36,42
24
ü
12,30,36,42
û
24
ü
12,30,36,42
42
ü
û
û
12,30,36,42
18,24
ü
û
24,30,36
42
ü
18,24
ü
30,36,42
ü
ü
û
24,30,36
42
û
18,24
ü
30,36,42
ü
û
ü
24,30,36
42
12,24,30,36,42
ü
30,36,42
ü
û
û
û
û
24
û
ü
42
û
û
SINGLE-ZONE PRODUCTS
M-SERIES SINGLE-ZONE PRODUCTS AND FEATURES
Total control for total comfort: single rooms can now have ultimate comfort with the
power of precise control over hot and cold spots.
SINGLE-ZONE, WALL-MOUNTED HEAT PUMPS Cooling and Heating
Slim, wall-mounted indoor units provide zone comfort control. INVERTER-driven compressors and
electronic LEVs provide higher efficiency with controlled power usage. The indoor unit is powered by the
outdoor unit and should a power outage occur, the system is automatically restored when power returns.
MSZ/MUZ-GL/D Heat Pumps | 1,500 - 33,200 Btu/h Capacity Range
• 100% heating at 5°F.
• 14.5 - 24.6 SEER, 8.2 - 12.8 HSPF, INVERTER-driven compressor.
• Auto restart and auto cooling/heating changeover.
• Vertical air swing on all units
• Compatible with kumo cloud ™ control app and Thermostat Interface.
• All models ENERGY STAR ® qualified.
MSZ/MUZ-FH High Efficiency Heat Pumps | 1,700 - 21,000 Btu/h Capacity Range
• Industry-leading efficiency of 33.1
SEER (MSZ-FH06NA and 30.5 SEER
(MSZ-FH09NA).
• Hyper-heating performance down to -13° F
outdoor ambient.
• Triple-action filtration.
-Nano-platinum filter.
-Electrostatic anti-allergen enzyme filter.
-Deodorizing filter.
• Double-vane air delivery for enhanced
circulation.
- Option to set each vane separately.
- Indirect or direct setting option.
- Natural flow setting that creates air
movement like a natural breeze.
• i-see Sensor™ 3D.
- Infrared human sensing technologies
to measure location of human heat
signatures.
Cooling Only
- i-see sensing floor temperature to deliver conditioned air to those areas
by double-vane airflow.
• NEW multi-function wireless controller.
• Optional controllers.
- Connects with Thermostat Interface
(PAC-US444CN-1) to allow for
operation with third-party thermostats.
-Compatible with Mitsubishi Electric
kumo cloud™ programmable
thermostat app (PAC-WHS01WF-E).
- MHK1 wireless wall-mounted controller
(compatible with Honeywell Remote
Internet Gateway for iPhone, Android,
smart device control via the internet).
- Wired wall-mounted controller
(PAR-31MAA requires MAC-333IF).
- Simple MA remote controller
(PAC-YT53CRAU requires MAC-333IF).
MSY/MUY Air Conditioners | 1,500–34,600 Btu/h Capacity Range
• 15.1 – 24.6 SEER, INVERTER compressor.
• Offers a wide vane for a wider angle of airflow, 150° from left to right.
• Motorized vertical vanes on GL24/D30/D36 models.
• All GL models ENERGY STAR® qualified.
M-Series systems are not recommended for critical room and low ambient cooling applications.
Use commercial grade P-Series with full cooling capacity down to 0° F with wind baffle.
MITSUBISHI ELECTRIC / M-SERIES / SPECIFICATIONS / 23
SINGLE-ZONE PRODUCTS
(CONTINUED)
SINGLE-ZONE, CEILING-RECESSED, CASSETTE HEAT PUMPS Cooling and Heating
SLZ 2'x2' ceiling-recessed cassette units offer a wide airflow pattern for better air
distribution in a less obtrusive style. Install SLZ in a hard ceiling (with an access
panel for servicing) or in 2'x2' drop ceiling.
SLZ/SUZ Heat Pumps | 3,100–17,700 Btu/h Capacity Range
• 15–16 SEER, 9.6 HSPF, INVERTER-driven compressor.
• Provides cooling and heating in a wide range of capacities.
• SLZ/SUZ-KA09/12 1:1 systems are ENERGY STAR® rated.
• Ventilation air knockouts.
• Built-in condensate lift mechanism (up to 20").
• Multiple airflow adjustments.
SINGLE-ZONE, HORIZONTAL-DUCTED HEAT PUMPS Cooling and Heating
SEZ ducted units provide comfort and efficiency while staying hidden either in the
ceiling or beneath the floor. All 1:1 systems are ENERGY STAR® certified.
SEZ/SUZ Heat Pumps | 3,800–19,000 Btu/h Capacity Range
• 15–17.5 SEER, 10 HSPF, INVERTER-driven compressor.
• Provides cooling and heating in a wide range of capacities.
• Built-in condensate lift mechanism (up to 21-11/16").
• Static capability up to 0.20" WG.
• Optional filter box with MERV-8 filters.
24 / MITSUBISHI ELECTRIC / M-SERIES / SPECIFICATIONS
M-SERIES ACCESSORIES
CN-24RELAY-KIT-CM3 RELAY KIT
The CN-24RELAY-KIT-CM3 connects to the CN24 connector on the
P-Series, SEZ and SLZ indoor unit control board to enable external
supplemental heating equipment. The CN-24RELAY-KIT-CM3 also
connects to the MAC-333IF-E System Control Interface to provide
the same function for M-Series indoor units.
•
•
•
•
Coil Voltage: 12V DC.
Power Consumption: 0.9 W or less.
Maximum Distance from indoor unit to relay: 32' (10m).
Wire Size: 18 to 22 AWG.
BASE PAN HEATERS
Base Pan Heaters limit ice build-up by preventing freezing before water drains from the base pan. The heater installs in
the bottom of the Base Pan and connects to the Indoor Control Board on FE and GE models.
• For installations where outdoor ambient temperatures are
expected to be below freezing for periods longer than 72
hours straight.
• Heater is energized when unit is in defrost.
• E12913527 for A models requires change of power
board—included—to operater heater.
DPLS2 DIAMONDBACK™ DRAIN PAN LEVEL SENSOR/CONTROL
A condensate sensor designed to fit the Mitsubishi Electric M-Series, P-Series and almost all of CITY MULTI® indoor
unit drain pans. DPLS2 shuts down the indoor unit when high condensate levels are detected in the drain pan.
•
•
•
•
•
Meets the intent of International Mechanical Code “allowed exception to the secondary drain pan requirement”.
All solid state—no floats or other moving parts—draws power from indoor unit.
Compact size with no additional energy consumption.
Includes harnesses for M-Series, P-Series and CITY MULTI indoor units.
Does not disrupt communications between the outdoor unit, compressor, and indoor unit.
MITSUBISHI ELECTRIC / M-SERIES / SPECIFICATIONS / 25
BALL VALVES
DIAMONDBACK™ BV-SERIES BALL VALVES
Diamondback BV-Series ball valves include the following features:
•
•
•
•
Engineered for mini-split and multi-split HVAC units.
Full port design with flare connections.
700 PSIG rated.
Flare or brazed connections.
PART
NUMBER
SAE
FLARE
BV14FFSI
BV38FFSI
BV12FFSI
BV58FFSI
1/4"
3/8"
1/2"
5/8"
A
B
C
D
E
ØF
6.26 2.67 1.81 1.23 1.42 1.10
6.30 2.67 1.81 1.23 1.42 1.10
6.51 2.67 1.81 1.23 1.42 1.10
6.64 2.67 1.81 1.23 1.42 1.10
Other important information:
PART
NUMBER
SAE
FLARE
BV14FFSI
BV38FFSI
BV12FFSI
BV58FFSI
1/4"
3/8"
1/2"
5/8"
A
B
•
•
•
•
•
C
D
E
ØF
ABOCINADO MACHO SAE
DE 1/4 PULG. C/CONEXIÓN DE ACCESO
ARI 720
(INCLUYE NÚCLEO
6.26 2.67 1.81 SEGÚN
1.23 1.42
1.10
TAPA DE SELLO)
6.30 2.67 1.81 DE
1.23VÁLVULA
1.42 Y1.10
6.51 2.67 1.81 1.23 1.42 1.10
6.64 2.67 1.81 1.23 1.42 1.10
C
D
ABOCINADO MACHO SAE
DE 1/4 PULG. C/CONEXIÓN DE ACCESO
SEGÚN ARI 720 (INCLUYE NÚCLEO
DE VÁLVULA Y TAPA DE SELLO)
E
ABOCINADO
MACHO SAE
ØF
0.74 ANCHO
PLANO
C
D
ABOCINADO
MACHO SAE
ØF
0.74 ANCHO
PLANO
ABOCINADO
HEMBRA SAE
(TUERCA LOCA)
B
•
•
•
•
B
E
Size available: 1/4", 3/8", 1/2", 5/8".
Fully factory assembled.
Furnace brazed and pressure tested.
Each ball valve is equipped with Schrader® Valve for refrigerant service.
Temperature range: -40˚ F to +325˚ F (-40˚ C to +149˚ C).
ABOCINADO
HEMBRA SAE
(TUERCA LOCA)
Forged brass body and seal cap.
Polytetrafluroethylene (PTFE) seals and gaskets (no synthetic O-rings).
Seal cap design permits valve operation without removal of seal cap.
One-year limited materials and workmanship warranty on ball valves.
A
A
Part Number
SAE Flare
A
B
C
D
E
F
BV14FFSI2
1/4"
6.26
2.67
1.81
1.23
1.42
1.10
BV38FFSI2
3/8"
6.30
2.67
1.81
1.23
1.42
1.10
BV12FFSI2
1/2"
6.51
2.67
1.81
1.23
1.42
1.10
BV58FFSI2
5/8"
6.64
2.67
1.81
1.23
1.42
1.10
* Ball valves come with an insulation piece.
PLATFORM STANDS
DIAMONDBACK PLATFORM STANDS
Lift the outdoor unit to new heights.
•
•
•
•
Easy to install.
Available for all sizes of mini-split or multi-split systems.
Color matched to the outdoor units.
One-year warranty.
Model DSD-400N
L: 15 3/4"
FILTER BOXES
W: 3 1/4"
H: 3 1/4"
FILTER BOXES
FB Series filter boxes are available in compatible sizes for all M-Series
horizontal ducted indoor units. FBL1 filter boxes include 1" thick pleated
MERV 8 filter(s) installed. Filters are tested in accordance with ANSI/
ASHRAE Standard 52.2 and Rated Class 2 under U.L. Standard 900.
The cabinet is constructed of non-insulated 20 gauge, G-60 galvanized
steel with a foam gasket and provides an air-tight connection to the
indoor unit and access door. Gasket material complies with UL 723
requirements. In addition, a screw-through cabinet design for secure
attachment to indoor unit and return connection in rear is easily converted
to bottom return.
26 / MITSUBISHI ELECTRIC / M-SERIES / SPECIFICATIONS
Part
Number
Part Description
FBL1-1
FB Series Filter Box for SEZ-KD09NA4
FBL1-2
FB Series Filter Box for SEZ-KD12/15NA4
FBL1-3
FB Series Filter Box for SEZ-KD18NA4
LINESETS
Lineset
Applied
Tube Size
Length
Part Number
Models
(IN.)
(FT.)
MLS143812T-15
MSZ-GL06 MSZ/YGL09/12, MSZ-FH09/12,
SEZ-KD09/12, MFZKA09/12
1/4 x 3/8
15
1/2"
MLS143812T-30
MSZ-GL06, MSZ/YGL09/12, MSZ-FH09/12,
SEZ-KD09/12, MFZKA09/13
1/4 x 3/8
30
1/2"
MLS143812T-50
MSZ-GL06, MSZ/YGL09/12, MSZ-FH09/12,
SEZ-KD09/12, MFZKA09/14
1/4 x 3/8
50
1/2"
MLS143812T-65
MSZ-GL06, MSZ/YGL09/12, MSZ-FH09/12,
SEZ-KD09/12, MFZKA09/15
1/4 x 3/8
65
1/2"
MLS141212T-15
MSZ/Y-GL15/18, MFZKA18, SEZ-KD15/18,
SLZ-KA15
1/4 x 1/2
15
1/2"
MLS141212T-30
MSZ/Y-GL15/18, MFZKA18, SEZ-KD15/18,
SLZ-KA15
1/4 x 1/2
30
1/2"
MLS141212T-50
MSZ/Y-GL15/18, MFZKA18, SEZ-KD15/18,
SLZ-KA15
1/4 x 1/2
50
1/2"
MLS141212T-65
MSZ/Y-GL15/18, MFZKA18, SEZ-KD15/18,
SLZ-KA15
1/4 x 1/2
65
1/2"
MLS141212T-100
MSZ/Y-GL15/18, MFZKA18, SEZ-KD15/18,
SLZ-KA15
1/4 x 1/2
100
1/2"
MPLS385812T-10
MSZ-FH18, MSZ/Y-GL24,
MSZ/Y-D30/36
3/8 x 5/8
10
1/2"
MPLS385812T-15
MSZ-FH18, MSZ/Y-GL24,
MSZ/Y-D30/36
3/8 x 5/8
15
1/2"
MPLS385812T-30
MSZ-FH18, MSZ/Y-GL24,
MSZ/Y-D30/36
3/8 x 5/8
30
1/2"
MPLS385812T-50
MSZ-FH18, MSZ/Y-GL24,
MSZ/Y-D30/36
3/8 x 5/8
50
1/2"
MPLS385812T-65
MSZ-FH18, MSZ/Y-GL24,
MSZ/Y-D30/36
3/8 x 5/8
65
1/2"
MPLS385812T-100
MSZ-FH18, MSZ/Y-GL24,
MSZ/Y-D30/36
3/8 x 5/8
100
1/2"
Caps On
DIAMONDBACK LINESETS
Diamondback linesets include the
following features:
• Quick, efficient, and economical field
installation using factory applied Twin Lube
insulation and flare connections with flare
nuts mounted.
• Correct lengths for reducing waste and time.
• Quality, consistency, and economy.
• All Diamondback lineset tubing is tested in
accordance with ASTM E243.
• One year warranty.
“TWIN-TUBE” LINESET
INSULATION DESIGN
• Balanced outside diameter for uniform
coil/uncoil position stability.
• Minimum 1/2" insulation thickness
on both tubes.
• Meets UL94 and ASTM E84 Standard.
Insul.
MITSUBISHI ELECTRIC / M-SERIES / SPECIFICATIONS / 27
QUICKSLING STANDS
Strong and reliable, Mini-split Stands are the mount of choice for
all M-Series outdoor units. Quick and easy to assemble, Mini-split
Stands are manufactured with heavy gauge, high-grade steel featuring
a color-matched thermally fused polyester powder coat finish that
meets ASTM D3451-06 standards. Each Mini-split Stand is provided
with galvanized mounting hardware and meets all ASCE 7 overturning
safety requirements, leading to a long service life. Designed and
manufactured in the United States, Mini-split Stands set the standard
for pre-engineered M-Series outdoor unit mounting systems.
M-Series Mini-split Stands
P-Series
Outdoor Units
QSMS1201M
MUY/Z-D30NA-1
X
X
X
MUY/Z-D36NA-1
X
X
X
MUZ-FH09NA-1
X
X
X
MUZ-FH12NA-1
X
X
X
QSMS1202M
QSMS1801M
QSMS1802M
QSMS2401M
QSMS2402M
MUZ-FH06NA
MUZ-FH15NA
X
X
X
MUZ-FH18NA2
X
X
X
MUY/Z-GL06NA-U1
X
X
X
MUY/Z-GL09NA-U8
X
X
X
MUY/Z-GL12NA-U1
X
X
X
MUY/Z-GL15NA-U1
X
X
X
MUY/Z-GL18NA-U1
X
X
X
MUY/Z-GL24NA-U1
X
X
X
SUZ-KA09NA
X
X
X
SUZ-KA12NA
X
X
X
SUZ-KA15NA
X
X
X
SUZ-KA18NA
X
X
X
MXZ-3C24NA
X
X
X
MXZ-3C30NA
X
X
X
MXZ-4C36NA
X
X
X
MXZ-5C42NA
X
X
X
X
MXZ-8C48NA
X
X
MXZ-2C20NAHZ
X
X
X
MXZ-3C24NAHZ
X
X
X
MXZ-3C30NAHZ
X
X
X
MXZ-4C36NAHZ
X
X
X
MXZ-5C42NAHZ
X
X
X
MXZ-8C48NAHZ
X
X
X
28 / MITSUBISHI ELECTRIC / M-SERIES / SPECIFICATIONS
M-SERIES ACCESSORIES
PART NUMBER
DESCRIPTION
FOR USE WITH
AIR OUTLET GUIDE
MAC-856SG-E
Outdoor air outlet guide for directing discharge air away from other outdoor unit
SUZ-KA18 outdoor units
MAC-886SG-E
Outdoor air outlet guide for directing discharge air away from other outdoor unit
MUZ/Y-FH15/18, MUZ/Y-GL18/24/, SUZ-KA18 outdoor units
MAC-889SG
Outdoor air outlet guide for directing discharge air away from other outdoor unit
MUZ/Y-GL09/12/15, MUZ-FH06/09/12, SUZ-KA09/12/15 outdoor units
MAC-891DS
Outdoor air outlet guide for directing discharge air away from other outdoor unit
MXZ-2B20 outdoor units
PAC-SH95AG-E
Air Protection Guide
All MXZ-8C and MXZ H2i 4C,5C outdoor units
PAC-SH96SG-E
Outdoor air outlet guide for directing discharge air away from other outdoor unit
All MXZ outdoor models
BALL VALVES
BV12FFSI2
Refrigeration Ball Valve-Flare/Schrader/Insulated - 1/2" size
All MXZ outdoor models and branch boxes
BV14FFSI2
Refrigeration Ball Valve-Flare/Schrader/Insulated - 1/4" size
All MXZ outdoor models and branch boxes
BV38FFSI2
Refrigeration Ball Valve-Flare/Schrader/Insulated - 3/8" size
All MXZ outdoor models and branch boxes
BV58FFSI2
Refrigeration Ball Valve-Flare/Schrader/Insulated - 5/8" size
All MXZ outdoor models and branch boxes
BOTTOM RETURN PLATE
BRP-1
Bottom Return Plate (Converts low profile ducted indoor unit from rear return to bottom return)
SEZ-KD09 indoor unit
BRP-2
Bottom Return Plate (Converts low profile ducted indoor unit from rear return to bottom return)
SEZ-KD12/15 indoor units
BRP-3
Bottom Return Plate (Converts low profile ducted indoor unit from rear return to bottom return)
SEZ-KD18 indoor unit
PAC-MKA30BC
Three Port Branch Box
MXZ Systems with two Branch Boxes
PAC-MKA50BC
Five Port Branch Box
MXZ Systems with two Branch Boxes
MSDD-50BR-E
Brazed Connections for connecting two branch boxes
MXZ-8C outdoor units
MSDD-50AR-E
Flared Connections for connecting two branch boxes
MXZ-8C outdoor units
C13-103
Blue Diamond Sensor Extension Cable - 15 Ft.
MaxiBlue and Mega Blue Blue Diamond Pumps
C13-192
Blue Diamond Alarm Sxtension Cable - 6.5 FT.
MaxiBlue and Mega Blue Blue Diamond Pumps
C21-014
Blue Diamond MultiTank - collection tank for use with multiple pumps
All Blue Diamond Pumps
F10-010
Blue Diamond Rubber Foot Pads
MaxiBlue and Mega Blue Blue Diamond Pumps
DPLS2
Drain Pan Level Sensor/Control for indoor unit shut off to prevent Drain Pan Overflow
All M-Series indoor units
SI30-115
Mini-Condensation pump - 115 volt application
All MSZ/Y, MFZ indoor units
SI30-230
Mini-Condensation pump - 230 volt application
All MSZ/Y, MFZ indoor units
X87-721
Advanced Blue Diamond Mini-Condensation pump w/ Resevoir & Sensor - 208/230 volt application
All M-Series Indoor Units up to 30,000 BTU
X87-711
Advanced Blue Diamond Mini-Condensation pump w/ Resevoir & Sensor - 110 volt application
All M-Series Indoor Units up to 30,000 BTU
X87-831
Advanced Blue Diamond Mini-Condensation pump w/ Resevoir & Sensor - 110 volt application
All M-Series Indoor Units up to 30,000 BTU
X87-835
Advanced Blue Diamond Mini-Condensation pump w/ Resevoir & Sensor - 208/230 volt application
All M-Series Indoor Units up to 30,000 BTU
Branch Box
CONDENSATE
CONTROL
ETC-211000MIT
Electic Heat Lockout Control
All MVZ Multi-position AHU
MCCH1
Portable Central Controller (PCC) - controls up to 16 RedLINK Zones - requires an MHK1 on each indoor unit
All M-Series indoor units equipped with MHK1 Controller
MHK1
Wireless wall-mounted remote controller (MRCH1) with a signal receiver (MIFH1) and cable (MRC1) all in one kit
All M-Series indoor units
MOS1
Outdoor Air Sensor - reads both outside temperature and humidity displayed on MRCH1 and MCCH1 if installed
All M-Series indoor units equipped with MHK1 Controller
PAC-IF01MNT-E
System Control Interface
MXZ-2C,3C,4C,5C outdoor units
PAC-YT53CRAU
Simple MA Remote Controller (requires MAC-333IF-E interface for MSY/Z and MFZ indoor units)
All MSZ/Y, MFZ, SEZ, SLZ indoor units
PAC-YU25HT-G
External Fan / Heater control relay adapter
Use CN24RELAY-KIT-CM3
PAC-735
Adaptor - Fan Speed Indicator
All MVZ Multi-position AHU
PAC-740
Adaptor - ERV Control
All MVZ Multi-position AHU
MAC-333IF-E
System Control Interface - MA, Contact terminal, and M-NET Control Adapter, Supplemental heat and humidifier adaptor
All MSZ, MSY, MFZ, SEZ, and SLZ
TAZ-MS303
3-Pole Disconnect Switch 30 Amps 600 volts rated for interupting power supply at/near indoor unit - fits 2 X 4 utility box
All M-Series Indoor Units
CN24RELAY-KIT-CM3
Relay Kit for external heater adapter connects to CN24 on indoor control board
All SEZ indoor units, MVZ Multi-position AHU
PAC-715AD
Wire for Remote on/off with CN32 connector
All SEZ, SLZ indoor units
PAC-725AD
Connector and wire for Operation status/error, booster fan control for fresh air using CN51
All SEZ, SLZ indoor units
PAC-SE41TS-E
Remote temperature sensor for indoor units
All SEZ, SLZ indoor units
PAC-SF40RM-E
Remote Operation Adapter with wire terminals for remote on/off and operation status/error
All SEZ, SLZ indoor units
PAR-FA32MA
Wireless Signal Receiver used with PAR-FL32MA
All SEZ, SLZ indoor units
PAR-FL32MA
Wireless Remote Controller used with PAR-FA32MA
All SEZ, SLZ indoor units
AIR OUTLET GUIDE
MITSUBISHI ELECTRIC / M-SERIES / SPECIFICATIONS / 29
Lockdown Bracket for wireless, hand-held, remote controllers
RCMKP1CB
All M-Series indoor units
DRAIN PAN
PAC-SH97DP-E
External drain pan used for stacking Outdoor Units. Prevents drain water from dripping on the lower units
All MXZ-8C and MXZ H2i 4C,5C outdoor units
DRAIN PAN HEATER
MAC-640BH-U
Outdoor Unit Drain Pan Heater used during defrost cycle
MUZ-GL09/12/15, MUZ-FH06/09/12, SUZ-KA09/12/15 outdoor
units
MAC-641BH-U
Outdoor Unit Drain Pan Heater used during defrost cycle
SUZ-KA18 outdoor units
MAC-642BH-U
Outdoor Unit Drain Pan Heater used during defrost cycle
MUZ-GL18/24, MUZ-FH12/18 outdoor units
MAC-645BH-E
Outdoor Unit Drain Pan Heater used during defrost cycle
MXZ-2C,3C,4C,5C outdoor units
DRAIN SOCKET
MAC-811DS
MAC-851DS
MAC-860DS
PAC-SG60DS-E
PAC-SG61DS-E
Outdoor drain pan socket - Provides pipe connection to route condensate out of drain pan
All MUZ/Y-D outdoor units
Outdoor drain pan socket - Provides pipe connection to route condensate out of drain pan
MUZ-GL18/24, MUZ-FH15/18 outdoor units
Outdoor drain pan socket - Provides pipe connection to route condensate out of drain pan
MUZ-FH06/09/12, MUY/MUZ-GL-24/SUZ-KA09/12/15, MXZ2C,3C,4C,5C outdoor units
Outdoor drain pan socket - Provides pipe connection to route condensate out of drain pan
MXZ-2C,3C,4C,5C outdoor units
Outdoor drain pan socket - Provides pipe connection to route condensate out of drain pan
MXZ-8C48NA outdoor units
ELECTRIC KIT HEATS
EH05-MPA-S
Electric Heat Kit for Multi-position AHU
Use with MVZ-A12/18/24 Multi-position AHU
EH03-MPA-S
Electric Heat Kit for Multi-position AHU
Use with MVZ-A12/18/24 Multi-position AHU
EH08-MPA-S
Electric Heat Kit for Multi-position AHU
Use with MVZ-A12/18/24 Multi-position AHU
EH08-MPA-M
Electric Heat Kit for Multi-position AHU
Use with MVZ-A18/24 Multi-position AHU
EH10-MPA-M
Electric Heat Kit for Multi-position AHU
Use with MVZ-A30/36 Multi-position AHU
FILTER BOX
FBL 1-1
FB SERIES Filter Box with MERV 8 Filters
SEZ-KD09 indoor units
FBL 1-2
FB SERIES Filter Box with MERV 8 Filters
SEZ-KD12/15 indoor units
FBL 1-3
FB SERIES Filter Box with MERV 8 Filters
SEZ-KD18 indoor units
MAC-1415FT-E
Anti-Allergy Enzyme Filter (qty of 2)
All MSZ/Y-D indoor units
MAC-2310FT-E
Anti-Allergy Enzyme Filter (qty of 2)
MSZ/Y-GL24 indoor units
MAC-3000FT-E
Deodorizing Filter
All MSZ-FH indoor units
MAC-408FT-E
Anti-Allergy Enzyme Filter (qty of 2)
MSZ/Y-GL06/09/12/15/18 indoor units
MAC-415FT-E
Anti-Allergy Enzyme Filter
All MFZ-KA indoor units
DSD-400P
Outdoor Unit 3-1/4 inch Mounting Base (Pair) - Plastic
All M-Series outdoor units
Condensing Unit Mounting Pad 16" x 36" x 3"
All MU,MUY/Z outdoor units, All SUZ outdoor units, and MXZ2C,3C,4C,5C outdoor units
FILTERS
OUTDOOR UNIT MOUNTING PAD
ULTRILITE1
Condensing Unit Mounting Pad 24" x 42" x 3"
ULTRILITE2
MXZ-8C and All MXZ H2i 4C,5C,8C outdoor units
OUTDOOR UNIT STAND
QSMS1201M
Outdoor Unit Stand - 12" High
Single Fan M-Series Outdoor Units
QSMS1801M
Outdoor Unit Stand - 18" High
Single Fan M-Series Outdoor Units
QSMS2401M
Outdoor Unit Stand - 24" High
Single Fan M-Series Outdoor Units
QSMS1202M
Outdoor Unit Stand - 12" High
Two Fan M-Series Outdoor Units
QSMS1802M
Outdoor Unit Stand - 18" High
Two Fan M-Series Outdoor Units
QSMS2402M
Outdoor Unit Stand - 24"High
Two Fan M-Series Outdoor Units
PORT ADAPTOR
Port Adapter size: 3/8" X 1/2"
All MXZ outdoor models and branch boxes
MAC-A455JP-E
Port Adapter size: 1/2" X 3/8"
All MXZ outdoor models and branch boxes
MAC-A456JP-E
Port Adapter size: 1/2" X 5/8"
All MXZ outdoor models and branch boxes
PAC-493PI
Port Adapter size: 1/4" x 3/8"
All MXZ outdoor models and branch boxes
PAC-SG76RJ-E
Port Adapter size: 3/8" x 5/8"
All MXZ outdoor models and branch boxes
QSMS2000M-1
Heavy Duty Wall Mounting Bracket for Outdoor Units - Coated Steel
All M-Series outdoor units
QSMS2000SS
Heavy Duty Wall Mounting Bracket for Outdoor Units - 316 Series Stainless Steel
All M-Series outdoor units
MAC-A454JP-E
WALL BRACKET
30 / MITSUBISHI ELECTRIC / M-SERIES / SPECIFICATIONS
M-SERIES PRODUCT SPECIFICATIONS
SINGLE-ZONE I MSY System
Cooling Only
Model Name
Cooling *1
Power Supply
Voltage
Indoor Unit
MSY-GL09NA-U1
MSY-GL12NA-U1
MSY-GL15NA-U1
MSY-GL18NA-U1
MSY-GL24NA-U1
Outdoor Unit
MUY-GL09NA-U1
MUY-GL12NA-U1
MUY-GL15NA-U1
MUY-GL18NA-U1
MUY-GL24NA-U1
Rated Capacity
Btu/h
9,000
12,000
14,000
18,000
22,500
Capacity Range
Btu/h
3,800 - 12,200
3,800 - 13,600
1,500 - 13,600
5,800-22,000
8,200-31,400
Rated Total Input
W
585
920
1,080
1,340
1800
Energy Efficiency
SEER
24.6
23.1
21.6
20.5
20.5
Pints/h
1.5
0.820
2.5
0.740
2.7
2.1
0.800
0.870
1 Phase, 60Hz, 208/230V *2
AC 208 / 230V
DC ±24V
Wireless Type (Optional Wired Controller: DC 12V)
1.0
0.76
0.67
5.1
0.750
Moisture Removal
Sensible Heat Factor
Phase, Cycle, Voltage
Indoor - Outdoor S1 - S2
Indoor - Outdoor S2 - S3
Indoor - Remote Controller
MCA
Blower Motor (ECM)
Airflow at Cooling
(Quiet-Lo-Med-Hi-Super Hi)*1
Indoor Unit
Sound Pressure Level at Cooling
(Quiet-Lo-Med-Hi-Super Hi)*1
Weight Unit
Field Drainpipe Size O.D.
Compressor
Outdoor Unit
145-170-237-321-399
205-272-335-420-533
259-333-416-523-646
388-469-544-628-738
WET (CFM)
109-134-201-286-364
170-237-300-385-498
233-300-375-470-581
347-420-487-562-661
26-32-38-44-49
28-33-38-44-49
34-41-45-49-53
36-5/16
9-13/16
12
28
43-5/16
9-3/8
12-13/16
37
dB(A)
19-22-30-37-43
19-22-30-37-45
Munsell 1.0Y 9.2 / 0.2
W: In.
D: In.
H: In.
Lbs.
In.
Type
MCA
MOCP
Fan Motor (ECM)
Airflow (Cooling)
Refrigerant Control
Sound Pressure Level at Cooling *1
31-7/16
9-1/8
11-5/8
22
5/8
Select from PAC-WHS01WF-E for kumo cloud™, PAC-US444CN-1, MHK1, PAR-31MAA, or PAC-YT53CRAU Remote Controllers
A
A
F.L.A.
Model
(Type)
R.L.A.
L.R.A.
CFM
dB(A)
7
9
Refrigerant
Weight
Type
Charge
Oil
Refrigerant
Pipe
Gas Side O.D.
Liquid Side O.D.
Refrigerant Pipe Height Difference (Max.)
Length
Length (Max.)
Connection
Indoor/Outdoor
Method
14
17.1
20
15
0.50
0.93
DC INVERTER-driven
DC INVERTER-driven Twin Rotary
4.9
6.1
1,229/1,172
6.8
8.5
1,243/1,229
Linear Expansion Valve
48
49
External Finish Color
Dimensions
0.76
DRY (CFM)
External Finish Color
Dimension Unit
Remote
Controller
A
F.L.A.
10.0
12.5
1,691/1,691
12.9
16.1
1,769/1,701
54
55
Munsell No. 3Y 7.8 / 1.1
W: In.
D: In.
31-1/2
11-1/4
H: In.
21-5/8
Lbs.
81
33-1/16
13
34-5/8
121
119
R410A
Lbs., Oz.
Type (fl. oz.)
In.
In.
2, 9
3, 7
FV50S (0.27)
4, 3
FV50S (0.35)
3/8
FV50S (0.40)
1/2
5/8
3/8
1/4
Ft..
40
50
Ft..
65
100
Flared/Flared
NOTES: Test conditions are based on AHRI 210/240.
*1. Rating conditions (cooling) - Indoor D.B. 80º F (27º C), W.B. 67º F (19º C); Outdoor: D.B. 95º F (35º C), W.B. 75º F (24º C).
*2. Indoor units receive power from outdoor units through field-supplied interconnected wiring.
Specifications are subject to change without notice.
LIMITED WARRANTY I Five years parts and seven years compressor.
MITSUBISHI ELECTRIC / M-SERIES / SPECIFICATIONS / 31
SINGLE-ZONE I MSY System
Cooling Only
Indoor Unit
Model Name
Cooling *1
Power Supply
Voltage
Outdoor Unit
MSY-D36NA-8
MUY-D30NA-1
MUY-D36NA-1
Rated Capacity
Btu/h
30,700
34,600
Capacity Range
Btu/h
9,800-30,700
9,800-34,600
Total Input
Energy Efficiency
Moisture Removal
Sensible Heat Factor
Phase, Cycle, Voltage
Indoor - Outdoor S1 - S2
Indoor - Outdoor S2 - S3
Indoor - Remote Controller
MCA
Blower Motor (ECM)
Airflow at Cooling (Quiet-Lo-Med-HiSuper Hi or Lo-Med-Hi-Powerful)*1
Indoor Unit
MSY-D30NA-8
Sound Pressure Level at Cooling
(Quiet-Lo-Med-Hi-Super Hi or
Lo-Med-Hi-Powerful) *1
W
3,380 (620-3,380)
4,240 (620-4,240)
SEER
16
15.1
Pints/h
9.9
0.64
11.9
0.62
A
F.L.A.
1-phase, 60Hz, 208 / 230V *2
AC 208 / 230V
DC ±24V
Wireless Type (Optional Wired Controller: DC 12V)
1.0
0.76
DRY (CFM)
389-639-848-887
WET (CFM)
350-576-763-798
dB(A)
32-42-49-51
External Finish Color
Dimension Unit
Weight Unit
Field Drainpipe Size O.D.
Remote
Controller
A
A
F.L.A.
46-1/16
11-5/8
14-3/8
40
5/8
Select from PAC-WHS01WF-E for kumo cloud™, PAC-US444CN-1, MHK1, PAR-32MAA,
or PAC-YT53CRAU Remote Controllers
21
25
0.93
Model (Type)
DC INVERTER-driven Twin Rotary
R.L.A.
L.R.A.
CFM
16
20
1,941
Linear Expansion Valve
Type
MCA
MOCP
Fan Motor (ECM)
Compressor
Outdoor Unit
Munsell No. 1.0Y 9.2 / 0.2
W: In.
D: In.
H: In.
Lbs.
In.
Airflow (Cooling)
Refrigerant Control
Sound Pressure Level at Cooling *1
dB(A)
External Finish Color
Dimensions
Refrigerant
Weight
Type
Charge
Refrigerant Pipe Length
Connection Method
56
W: In.
D: In.
Munsell No. 3Y 7.8 / 1.1
33-1/16
13
H: In.
33-7/16
Lbs.
Lbs., Oz.
126
R410A
4
Type (fl. oz.)
NE022 (29.4)
Gas Side O.D.
Liquid Side O.D.
In.
In.
5/8
3/8
Height Difference (Max.)
Ft..
50
Length (Max.)
Indoor/Outdoor
Ft..
100
Flared/Flared
Oil
Refrigerant Pipe
55
NOTES: Test conditions are based on AHRI 210/240.
*1. Rating conditions (cooling) - Indoor D.B. 80º F (27º C), W.B. 67º F (19º C); Outdoor: D.B. 95º F (35º C), W.B. 75º F (24º C).
*2. Indoor units receive power from outdoor units through field-supplied interconnected wiring.
Specifications are subject to change without notice.
LIMITED WARRANTY I Five years parts and seven years compressor.
32 / MITSUBISHI ELECTRIC / M-SERIES / SPECIFICATIONS
SINGLE-ZONE I MSZ Indoor Unit I Heat Pump
Cooling *1
Heating
at 47° F *2
Heating
at 17° F *3
Heating
at 5° F
Power
Supply
Voltage
MSZ-FH06NA
MSZ-FH09NA
MSZ-FH12NA
MSZ-FH15NA
Outdoor Unit
MUZ-FH06NA
MUZ-FH09NA-1
MUZ-FH12NA-1
MUZ-FH15NA
6,000
1,700 - 9,000
315
33.1
0.2
0.960
8,700
1,600 - 14,000
545
13.5
5,900
500
10,700
9,000
1,700-12,000
560
30.5
0.6
0.920
10,900
1,600-18,000
710
13.5
6,700
600
12,200
12,000
2,500-13,600
870
26.1
1.9
0.830
13,600
3,700-21,000
950
12.5
8,000
720
13,600
15,000
6,450 -19,000
1,200
22.0
4.0
0.700
18,000
5,150 - 24,000
1,300
12.0
11,000
1,020
18,000
17,200
6,450-21,000
1,375
21.0
4.8
0.690
20,300
5,150-30,000
1,720
12.0
13,700
1,320
20,300
8,700
10,900
13,600
18,000
20,300
Rated Capacity
Capacity Range
Rated Total Input
Energy Efficiency
Moisture Removal
Sensible Heat Factor
Rated Capacity
Capacity Range
Rated Total Input
HSPF (IV)
Rated Capacity
Rated Total Input
Maximum Capacity
Btu/h
Btu/h
W
SEER
Pints/h
Maximum Capacity
Btu/h
Airflow at Heating
(Quiet-Low-Med.-High-Super Hi) *2
Sound Pressure Level at Cooling
(Quiet-Low-Med.-High-Super Hi) *1
Sound Pressure Level at Heating
(Quiet-Low-Med.-High-Super Hi) *2
External Finish Color
Dimension Unit
Weight Unit
Field Drainpipe Size O.D.
Remote Controller
1 Phase, 60Hz, 208/230V *4
AC 208 / 230V
DC ±24V
Wireless Type (Optional Wired Controller: DC12V)
1.0
0.67
A
F.L.A.
DRY (CFM)
137-167-221-304-381
137-167-221-304-381
137-167-221-304-398
225-262-304-355-411
WET (CFM)
117-143-190-261-328
117-143-190-261-328
117-143-190-261-342
194-225-261-305-354
DRY (CFM)
140-167-225-325-437
140-167-225-325-437
140-167-225-325-454
201-254-317-394-497
dB(A)
20-23-29-36-40
20-23-29-36-40
21-24-29-36-41
27-31-35-39-47
dB(A)
20-24-29-36-42
20-24-29-36-42
21-24-29-36-42
25-29-34-39-46
Munsell No. 1.0Y 9.2 / 0.2
36-7/16
9-3/16
12(+11/16)
29
5/8
Select from PAC-WHS01WF-E for kumo cloud™, PAC-US444CN-1,
MHK1, PAR-31MAA, or PAC-YT53CRAU Remote Controllers
11
16
15
0.50
W: In.
D: In.
H: In.
Lbs.
In.
Type
MCA
MOCP
Fan Motor (ECM)
Compressor
Outdoor Unit
Btu/h
Btu/h
W
Btu/h/W
Btu/h
W
Btu/h
Phase, Cycle, Voltage
Indoor - Outdoor S1 - S2
Indoor - Outdoor S2 - S3
Indoor - Remote Controller
MCA
Blower Motor (ECM)
Airflow at Cooling
(Quiet-Low-Med.-HighSuper Hi) *1
Indoor Unit
Airflow (Cooling/Heating)
Refrigerant Control
Defrost Method
Sound Pressure Level
at Cooling *1
Sound Pressure Level
at Heating *2
External Finish Color
Dimensions
MSZFH18NA2
MUZFH18NA2
Indoor Unit
Model Name
A
A
F.L.A.
Model
(Type)
R.L.A.
L.R.A.
CFM
1,150/1,280
dB(A)
47
48
dB(A)
48
49
225-262-304355-459
194-225-261305-395
201-254-317394-514
20-23-2936-40
20-24-2936-42
15
20
0.93
DC INVERTER-driven Twin Rotary
8.2
10.3
12.0
15.0
1,190/1,320
10.0
12.5
1,692/1,634
49
51
52
51
55
55
1,074/1,202
Linear Expansion Valve
Reverse Cycle
Munsell No. 3Y 7.8 / 1.1
W: In.
D: In.
H: In.
Lbs.
Weight
Type
Refrigerant
Charge
Lbs., Oz.
Oil
Type (cc)
Gas Side O.D.
In.
Refrigerant Pipe
Liquid Side O.D.
In.
Height Difference (Max.)
Ft.
Refrigerant
Pipe Length
Length (Max.)
Ft.
Connection Method Indoor/Outdoor
NOTES: Test conditions are based on AHRI 210/240.
*1. Rating conditions (cooling)-Indoor: D.B. 80º F (27º C), W.B. 67º F (19º C);
Outdoor: D.B. 95º F (35º C), W.B. 75º F (24º C).
*2. Rating conditions (heating)-Indoor: D.B. 70º F (21º C), W.B. 60º F (16º C);
Outdoor: D.B. 47º F (8º C), W.B. 43º F (6º C).
31-1/2
11-1/4
21-5/8
81
33-1/16
13
34-5/8
124
R410A
2, 9
FV50S (350)
3/8
3, 7
FV50S (400)
1/2
1/4
40
65
50
100
Flared/Flared
*3. Rating conditions (heating)-Indoor: D.B. 70º F (21º C), W.B. 60º F (16º C);
Outdoor: D.B. 17º F (-8º C), W.B. 15º F (-9º C).
*4. Indoor units receive power from outdoor units through field-supplied interconnected wiring.
Specifications are subject to change without notice.
LIMITED WARRANTY I Five years parts and seven years compressor.
MITSUBISHI ELECTRIC / M-SERIES / SPECIFICATIONS / 33
SINGLE-ZONE I MSZ System I Heat Pump
Model Name
Cooling *1
Heating at 47°
F *2
Heating at 17°
F *3
Heating at 5° F
Power Supply
Voltage
Indoor Unit
MSZ-GL09NA-U1
MSZ-GL12NA-U1
MSZ-GL15NA-U1
MSZ-GL18NA-U1
MSZ-GL24NA-U1
Outdoor Unit
MUZ-GL09NA-U8
MUZ-GL12NA-U1
MUZ-GL15NA-U1
MUZ-GL18NA-U1
MUZ-GL24NA-U1
Rated Capacity
Btu/h
9,000
12,000
14,000
18,000
22,400
Capacity Range
Btu/h
3,600 - 12,200
1,500 - 13,600
3,100 - 18,200
5,800 - 22,000
8,200 - 31,400
Rated Total Input
W
585
920
1,080
1,340
1,800
Energy Efficiency
SEER
24.6
23.1
21.6
20.5
20.5
Moisture Removal
Sensible Heat Factor
Pints/h
1.5
0.820
2.5
0.740
2.7
0.800
2.1
0.870
5.1
0.750
10,900
14,400
18,000
21,600
4,500 - 14,100
720
12.8
7,000
620
9,400
7,600
5,500 - 18,100
1,100
12.5
12,000
9,200
1,240
9,700
Rated Capacity
Btu/h
Capacity Range
Rated Total Input
HSPF (IV)
Rated Capacity
Rated Total Input
Maximum Capacity
Maximum Capacity
Phase, Cycle, Voltage
Indoor - Outdoor S1 - S2
Indoor - Outdoor S2 - S3
Indoor - Remote Controller
MCA
Blower Motor (ECM)
Btu/h
W
Btu/h/W
Btu/h
W
Btu/h
Btu/h
Airflow at Cooling
(Quiet-Lo-Med-Hi-Super Hi) *1
Indoor Unit
Airflow at Heating
(Quiet-Lo-Med-Hi-Super Hi) *2
External Static Pressure
Sound Pressure Level at Cooling
(Quiet-Lo-Med-Hi-Super Hi) *1
Sound Pressure Level at Heating
(Quiet-Lo-Med-Hi-Super Hi) *2
A
F.L.A.
Weight Unit
Field Drainpipe Size O.D.
Remote
Controller
Fan Motor (ECM)
Compressor
Airflow (Cooling/Heating)
Outdoor Unit
205-272-335-420-533
259-333-416-523-646
388-469-544-628-738
WET (CFM)
109-134-201-286-364
170-237-300-385-498
233-300-375-470-581
347-420-487-562-661
DRY (CFM)
145-170-237-321-406
205-247-304-367-463
296-384-469-563-646
388-469-544-628-738
In. WG
dB(A)
19-22-30-37-43
19-22-30-37-45
26-32-38-44-49
28-33-38-44-49
34-41-45-49-53
dB(A)
19-22-30-37-43
19-22-30-37-43
26-30-35-40-46
28-33-38-43-48
32-41-45-49-52
36-5/16
9-13/16
12
28
43-5/16
9-3/8
12-13/16
37
Munsell 1.0Y 9.2 / 0.2
W: In.
D: In.
H: In.
Lbs.
In.
31-7/16
9-1/8
11-5/8
22
5/8
Select from PAC-WHS01WF-E for kumo cloud™, PAC-US444CN-1, MHK1, PAR-31MAA, or PAC-YT53CRAU Remote Controllers
A
A
9
F.L.A.
Model
(Type)
R.L.A.
L.R.A.
CFM
10
Refrigerant Pipe
Refrigerant Pipe
Length
Connection
Method
14
17.1
20
15
0.5
0.93
DC INVERTER-driven Twin Rotary
6.2
7.7
1,229/1,172
6.6
8.2
1,229 / 1,172
7.4
9.3
1,243 / 1,229
Refrigerant Control
10.0
12.5
1,691 / 1,691
12.9
16.1
1,769 / 1,701
Linear Expansion Valve
Defrost Method
Refrigerant
0.76
145-170-237-321-399
Type
MCA
MOCP
7,500 - 36,900
2,340
10.0
24,600
16,000
3,290
21,160
DRY (CFM)
External Finish Color
Dimension Unit
27,600
4,800 - 20,900
5,400 - 25,000
1,600
1,680
11.7
11.2
16,400
18,200
12,200
13,800
1,850
2,150
13,700
14,500
1 Phase, 60Hz, 208/230V *4
AC 208 / 230V
DC ±24V
Wireless Type (Optional Wired Controller: DC12V)
1.0
0.76
0.67
Reverse Cycle
Sound Pressure Level at Cooling *1
dB(A)
48
49
Sound Pressure Level at Heating *2
External Finish Color
dB(A)
50
51
54
55
55
Munsell No. 3Y 7.8 / 1.1
W: In.
31-1/2
33-1/16
Dimensions
D: In.
H: In.
11-1/4
21-5/8
13
34-5/8
Weight
Lbs.
81
121
119
Type
Charge
R410A
Lbs., Oz.
Oil
Type (fl. oz.)
Gas Side O.D.
Liquid Side O.D.
In.
In.
Height Difference (Max.)
Ft.
40
50
Length (Max.)
Ft.
65
100
Indoor/Outdoor
NOTES: Test conditions are based on AHRI 210/240.
*1. Rating conditions (cooling)-Indoor: D.B. 80º F (27º C), W.B. 67º F (19º C);
Outdoor: D.B. 95º F (35º C), W.B. 75º F (24º C).
*2. Rating conditions (heating)-Indoor: D.B. 70º F (21º C), W.B. 60º F (16º C);
Outdoor: D.B. 47º F (8º C), W.B. 43º F (6º C).
34 / MITSUBISHI ELECTRIC / M-SERIES / SPECIFICATIONS
2, 9
3, 7
4, 3
FV50S (0.35)
3/8
FV50S (0.40)
1/2
5/8
3/8
1/4
Flared/Flared
*3. Rating conditions (heating)-Indoor: D.B. 70º F (21º C), W.B. 60º F (16º C);
Outdoor: D.B. 17º F (-8º C), W.B. 15º F (-9º C).
*4. Indoor units receive power from outdoor units through field-supplied interconnected wiring.
Specifications are subject to change without notice.
LIMITED WARRANTY I Five years parts and seven years compressor.
SINGLE-ZONE I MSZ System I Heat Pump
Model Name
Cooling *1
Indoor Unit
MSZ-D30NA-8
MSZ-D36NA -8
Outdoor Unit
MUZ-D30NA-1
MUZ-D36NA-1
Rated Capacity
Btu/h
30,700
33,200
Capacity Range
Btu/h
9,800-30,700
9,800-33,200
Total Input
W
Energy Efficiency
SEER
Moisture Removal
Pints/h
3,850 (620-3,850)
Sensible Heat Factor
Heating
at 47º F *2
Heating
at 17º F *3
4,360 (620-4,360)
14.5
Rated Capacity
Btu/h
Capacity Range
Btu/h
Total Input
W
HSPF (Region IV)
Btu/h/W
Rated Capacity
Btu/h
Rated Total Input
W
9.9
11.3
0.64
0.62
32,600
35,200
8,700-34,000
8,700-36,000
3,360 (520-3,600)
3,840 (520-4,100)
8.2
19,500
21,800
2,620 *5
3,000 *5
Maximum Capacity
Btu/h
20,800
22,800
Heating at 5º F
Maximum Capacity
Btu/h
16,305
19,090
Power Supply
Phase, Cycle, Voltage
Indoor - Outdoor S1-S2
Indoor - Outdoor S2-S3
Indoor - Remote Controller
MCA
Blower Motor (ECM)
Voltage
Airflow at Cooling (Lo-Med-Hi-Super HI-Powerful) *1
Airflow at Heating (Lo-Med-Hi-SuperHI-Powerful) *2
Sound Pressure Level (Cooling) (Lo-Med-Hi-Super HI-Powerful) *1
Indoor Unit
Sound Pressure Level (Heating) (Lo-Med-Hi-Super HI-Powerful) *2
1 Phase, 60Hz, 208 / 230V *4
AC 208-230V
DC ±24V
1.0
0.76
A
F.L.A.
DRY (CFM)
389-639-848-887
WET (CFM)
350-576-763-798
DRY (CFM)
445-639-848-887
32-42-49-51
dB(A)
34-42-49-50
External Finish Color
Dimension Unit
Remote Controller
Munsell No. 1.0Y 9.2 / 0.2
W: In.
46-1/16
D: In.
11-5/8
H: In.
14-3/8
Weight Unit
Lbs.
40
Field Drainpipe Size O.D.
In.
5/8
Select from PAC-WHS01WF-E for kumo cloud™, PAC-US444CN-1, MHK1, PAR-32MAA,
or PAC-YT53CRAU Remote Controllers
Type
MCA
A
MOCP
A
Fan Motor (ECM)
F.L.A.
21
25
0.93
Model (Type)
Compressor
Airflow
Outdoor Unit
16
L.R.A.
20
CFM
1,941
Refrigerant Control
Linear Expansion Valve
Defrost Method
Revese Cycle
Sound Pressure Level at Cooling *1
dB(A)
Sound Pressure Level at Heating *2
dB(A)
55
Munsell No. 3Y 7.8/1.1
W: In.
Dimensions
Weight
33-1/16
D: In.
13
H: In.
33-7/16
Lbs.
141
Type
Refrigerant Pipe
Lbs., Oz.
Oil
Type (Fl. Oz.)
Liquid Side O.D.
Height Difference (Max.)
Length (Max.)
Connection Method
R410A
Charge
Gas Side O.D.
Indoor/Outdoor
NOTES: Test conditions are based on AHRI 210/240.
*1. Rating conditions (cooling)-Indoor: D.B. 80º F (27º C), W.B. 67º F (19º C);
Outdoor: D.B. 95º F (35º C), W.B. 75º F (24º C).
*2. Rating conditions (heating)-Indoor: D.B. 70º F (21º C), W.B. 60º F (16º C);
Outdoor: D.B. 47º F (8º C), W.B. 43º F (6º C).
*3. Rating conditions (heating)-Indoor: D.B. 70º F (21º C), W.B. 60º F (16º C);
56
57
External Finish Color
Refrigerant
DC INVERTER-driven Twin Rotary
R.L.A.
In.
Ft.
4, 10
NE022 (29.4)
5/8
3/8
50
100
Flared/Flared
Outdoor: D.B. 17º F (-8º C), W.B. 15º F (-9º C).
*4. Indoor units receive power from outdoor units through field-supplied interconnected wiring.
*5. Maximum Total Input
Specifications are subject to change without notice.
LIMITED WARRANTY I Five years parts and seven years compressor.
MITSUBISHI ELECTRIC / M-SERIES / SPECIFICATIONS / 35
SINGLE-ZONE I SEZ System I Heat Pump
Indoor Unit
Outdoor Unit
Model Name
Cooling *1
Heating at 47° F *2
Heating at 17° F *3
Power Supply
Voltage
Btu/h
8,100
11,500
14,100
17,200
3,800-10,900
3,800-13,300
3,800-17,000
3,800-19,000
Total Input
W
670
920
1,170
1,380
Energy Efficiency
Moisture Removal
Sensible Heat Factor
SEER
Pints/h
15
1.5
0.80
16
2.4
0.76
15.5
2.6
0.80
17.5
3.4
0.79
Rated Capacity
Btu/h
Capacity Range
Total Input
HSPF (IV)
Rated Capacity
Rated Total Input
Maximum Capacity
Phase, Cycle, Voltage
Indoor - Outdoor S1 - S2
Indoor - Outdoor S2 - S3
MCA
Blower Motor (ECM)
Btu/h
W
Btu/h/W
Btu/h
W
Btu/h
External Static Pressure *3
Sound Pressure Level (Lo-Med-Hi)
External Finish
Compressor
Airflow (Cooling/Heating)
Refrigerant Pipe Length
Connection Method
10,900
13,600
18,000
21,600
4,800-14,100
1,020
4,800-16,400
1,140
4,800-21,100
1,500
4,800-24,900
1,700
10.0
9,000
11,900
920
1,200
9,000
11,900
1 Phase, 60Hz, 208 / 230V *4
AC 208-230V
DC ±24V
1
0.57
6,700
810
6,700
0.51
Defrost Method
Sound Pressure Level at Cooling *1
Sound Pressure Level at Heating *2
External Finish Color
13,100
1,350
13,100
0.74
DRY (CFM)
194-247-317
247-317-388
353-441-529
423-529-635
WET (CFM)
In. W.G.
dB(A)
174-222-285
222-285-349
317-396-476
0.02-0.06-0.14-0.20
23-28-33
30-34-37
Galvanized-Steel Sheets
39
27-9/16
7-7/8
50
54
21-11/16
1-1/4
381-476-572
W: In.
D: In.
H: In.
Lbs.
H: In.
In.
23-26-30
31-1/8
42
30-34-38
46-7/8
62
Select from PAC-WHS01WF-E for kumo cloud™, PAC-US444CN-1, MHK1, PAR-32MAA, or PAC-YT53CRAU
Remote Controllers
A
A
F.L.A.
Model (Type)
R.L.A.
L.R.A.
CFM
12
14
15
0.50
0.93
DC Inverter
6.6
8.2
1,151/1,225
DC Inverter Twin Rotary
7.4
9.3
1,243/1,229
1,229/1,172
Refrigerant Control
Dimensions
Refrigerant Pipe
A
F.L.A.
Type
MCA
MOCP
Fan Motor (ECM)
Refrigerant
SEZ-KD18NA4
SUZ-KA18NA
Btu/h
Weight Unit
Drain-lift Mechanism
Field Drainpipe Size O.D.
Outdoor Unit
SEZ-KD15NA4
SUZ-KA15NA
Rated Capacity
Dimension Unit
Remote Controller
SEZ-KD12NA4
SUZ-KA12NA
Capacity Range
Airflow at Cooling/Heating (Lo-Med-Hi)
Indoor Unit
SEZ-KD09NA4
SUZ-KA09NA
10
12.5
1,730/1,659
Linear Expansion Valve
W: In.
Reverse Cycle
49
51
Munsell No. 3Y 7.8/1.1
31-1/2
D: In.
11-1/4
13
H: In.
Lbs.
21-5/8
77
33-7/16
119
dB(A)
dB(A)
46
50
33-1/6
Weight
Type
Charge
Oil
Gas Side O.D.
Liquid Side O.D.
Lbs., Oz.
Type (fl. oz.)
In.
In.
Height Difference (Max.)
Ft.
40
50
Length (Max.)
Indoor/Outdoor
Ft.
65
100
NOTES: Test conditions are based on AHRI 210/240.
*1. Rating conditions (cooling)-Indoor: D.B. 80º F (27º C), W.B. 67º F (19º C);
Outdoor: D.B. 95º F (35º C), W.B. 75º F (24º C).
*2. Rating conditions (heating)-Indoor: D.B. 70º F (21º C), W.B. 60º F (16º C);
Outdoor: D.B. 47º F (8º C), W.B. 43º F (6º C).
*3. Rating conditions (heating)-Indoor: D.B. 70º F (21º C), W.B. 60º F (16º C);
Outdoor: D.B. 17º F (-8º C), W.B. 15º F (-9º C).
*4. Indoor units receive power from outdoor units through field-supplied interconnected wiring.
36 / MITSUBISHI ELECTRIC / M-SERIES / SPECIFICATIONS
66
54
56
80
R410A
2, 9
2
NEO22 (10.8)
3/8
4
NEO22 (15.2)
1/2
1/4
Flared/Flared
Specifications are subject to change without notice.
LIMITED WARRANTY I Five years parts and seven years compressor.
Presi
Presió
Presió
Presión
Alta Alta
MedioMedio
[0.04] [0.04]
nominal
PuntoPunto
nominal
Baja Baja
[0.04] [0.04]
Baja Baja
RatedRated
point point
0
0
[141] [141] [176] [176] [212] [212] [247] [247] [282] [282] [318] [318] [353] [353]
Tasa
dede
flujo
aire [pies3/min]
Tasa de
flujo
airede[pies3/min]
SEZ STATIC PERFORMANCE CURVES
SEZ-KD12NA4
SEZ-KD12NA4
externa
de 0.02[pulg.WG])
208/230V
(Presión(Presión
estática estática
externa de
0.02[pulg.WG])
208/230V
60Hz 60Hz
SEZ-KD09NA4
SEZ-KD09NA4
[0.16]
[0.16]
[0.20]
Límite
(Presión
estática
externa
de 0.14[pulg.WG])
208/230V
(Presión
estática
externa
de 0.14[pulg.WG])
208/230V
60Hz60Hz
80
80
[0.32] [0.32]
Límite
(Presión
estática
externa
de 0.20[pulg.WG])
208/230V
(Presión
estática
externa
de 0.20[pulg.WG])
208/230V
60Hz60Hz
[0.32] [0.32]
LímiteLímite
Presión estática externa [pulg.WG]
Presión estática externa [pulg.WG]
Presión estática externa [pulg.WG]
Alta
Punto nominal
Baja
0
[141]
[353]
[176]
[212]
[247]
[282]
Tasa de flujo de aire [pies3/min]
[318]
Alta
nominalAlta
PuntoPunto
nominal
MedioMedio
Medio
Medio
20
20
[0.08] [0.08]
Punto nominal
Punto nominal
(Presión estática externa de 0.06[pulg.WG]) 208/230V 60Hz (Presión
(Presión
estática
externa
de 0.14[pulg.WG])
208/230V
externa de
0.14[pulg.WG])
208/230V
60Hz 60Hz
[0.16]estática
[0.16]
SEZ-KD09NA4
8/230V 60Hz
[0.20] estática externa de 0.20[pulg.WG]) 208/230V 60Hz
(Presión
Alta Alta
nominal
PuntoPunto
nominal
Alta
[0.20] [0.20]
[0.08]
[0.08]
[0.16] [0.16]
[0.12] [0.12]
[0.04]
[0.04]
[0.08] [0.08]
Baja
Baja Baja
Baja
SEZ-KD15NA4
SEZ-KD15NA4
(Presión
(Presión
estática
estática
externa
externa
de 0.06[pulg.WG])
de 0.06[pulg.WG])
208/230V
208/230V
60Hz 60Hz
SEZ-KD12NA4
SEZ-KD12NA4
(Presión
externa
de 0.20[pulg.WG])
208/230V
(Presión
estática estática
externa de
0.20[pulg.WG])
208/230V
60Hz 60Hz
[0.20] [0.20]
Límite Límite
[0.32]
[0.04]
[0.08]
[353]
n]
208/230V 60Hz
[0.04]
0
[212]
0
[247]
[141]
[176]
[282]
[318]
[353]
Tasa
de aire [pies3/min]
[212] de flujo[247]
[282]
Tasa de flujo de aire [pies3/min]
3]
in]
Punto nominal
[388]
[565]
Medio
Punto nominal
[424]
[353]
[388]
[424]
[459]
[494]
Tasa de flujo de aire [pies3/min]
[247]
[282]
[318]
[353]
[0.20]
80
[0.32]
Presión estática externa [pulg.WG]
Presión estática externa [pulg.WG]
ta
Alta
[600]
[636]
[530]
[671]
[565]
10
[0.04]
0
[318]
0
[282]
Alta
Punto nominal
Baja
Punto nominal
Baja
2010
[0.04]
[0.08]
Punto nominal
[353]
[388]
[318]
[424]
[459]
[494]
[530]
[565]
de flujo
de aire [459]
[pies3/min]
[353] Tasa
[388]
[424]
[494]
Tasa de flujo de aire [pies3/min]
[600]
[636]
[530]
SEZ-KD18NA4
208/230V 60Hz
(Presión estática externa de 0.20[pulg.WG]) 208/230V 60Hz
[0.32]
Presión estática externa [pulg.WG]
Presión estática externa [pulg.WG]
40
40
[0.16]
20 [0.16]
20
[0.08] [0.08]
30
30
[0.12] [0.12]
PuntoPunto
nominal
nominal
Alta
Punto nominal
Punto nominal
Medio
MedioMedio
Medio
Baja Baja
Baja
Baja
PuntoPunto
nominal
nominal
10
10
[0.04] [0.04]
0
0
[318]
[353] [353]
[388] [388]
[424] [424]
[459] [459]
[494] [494]
[530] [530]
[565] [565]
[600] [600]
[636] [636]
[671] [671]
0
0[318]
Tasa
de flujo
de
de
flujo
aire
de[459]
[pies3/min]
aire [pies3/min]
[282] [282]
[318] [318]
[353] Tasa
[353]
[388]
[388]
[424]
[424]
[459]
[494] [494]
[530] [530]
[565] [565]
Tasa deTasa
flujode
deflujo
aire de
[pies3/min]
aire [pies3/min]
SEZ-KD18NA4
SEZ-KD18NA4
SEZ-KD18NA4
SEZ-KD18NA4
(Presión
(Presión
estática
estática
externa
externa
de 0.14[pulg.WG])
de 0.14[pulg.WG])
208/230V
208/230V
60Hz60Hz
(Presión
(Presión
estática
estática
externa
externa
de 0.20[pulg.WG])
de 0.20[pulg.WG])
208/230V
208/230V
60Hz60Hz
[0.32] [0.32]
[0.32] [0.32]
LímiteLímite
LímiteLímite
Medio
Medio
40
[0.16]
20
[0.08]
30
[0.12]
unto nominal
Baja
Tasa
de flujo
de
de
flujo
aire
de[459]
[pies3/min]
aire [pies3/min]
[282] [282]
[318] [318]
[353] Tasa
[353]
[388]
[388]
[424]
[424]
[459]
[494] [494]
[530] [530]
[565] [565]
Tasa deTasa
flujode
deflujo
aire de
[pies3/min]
aire [pies3/min]
[565]
Alta
Alta Alta
30 30
50 [0.12]
50
[0.12]
[0.20] [0.20]
[0.28] [0.28]
30
50
[0.12]
[0.20]
Alta
Baja
Límite
Límite
60
[0.24]
LímiteLímite
Límite Límite
70
70
40 [0.28]
40
[0.28]
[0.16] [0.16]
[424]
7040
[0.28]
[0.16]
Límite
[565]
[388]
50 estática externa de 0.20[pulg.WG]) 208/230V 60Hz
(Presión
Límite
3/min]
[494]
min]
[530]
Baja
[0.20] [0.20]
80
80
[0.32] [0.32]
10
2010 20
[0.08]
[0.08]
[0.04] [0.04]
[0.04] [0.04]
0
0
[388] [388]
[424] [424]
[459] [459]
[494] [494]
[530] [530]
[565] [565]
[600] [600]
[636] [636]
[671] [671]
0 [318] [318]
0 [353] [353]
Baja
Tasa de flujo de aire [pies3/min]
SEZ-KD18NA4
(Presión estática externa de 0.06[pulg.WG]) 208/230V 60Hz
SEZ-KD15NA4
208/230V 60Hz
208/230V 60Hz
Punto nominal
Punto nominal
Medio Medio
MedioMedio
Baja Baja
[318]
Alta
Alta Alta
[0.04] [0.04]
[0.08] [0.08]
[0.12]
[0.04]
0
[212]
[0.08] [0.08]
[0.12] [0.12]
Baja
0
[282]
[0.04]
Alta
[0.16] [0.16]
Alta
Medio
[0.08]
[0.16]
Baja
0
[0.04]
[0.04]0
[282] [282]
[318] [318]
[353] [353]
[388] [388]
[424] [424]
[459] [459]
[494] [494]
[530] [530]
[565] [565]
Tasa deTasa
flujode
deflujo
aire de
[pies3/min]
aire [pies3/min]
0
0
[212]
[247]
[282]
[318]
[353]
[388]
[424]
[212]
[247]
[282]
[318]
[353]
[388]
[424]
Tasa
flujo
de aire [pies3/min]
Tasa de flujo
dede
aire
[pies3/min]
60
60
[0.24] [0.24]
[0.20] [0.20]
[0.08]
[530]
Límite Límite
[0.12] [0.12]
Presión estática externa [pulg.WG]
[494]
min]
[0.20]
[0.04] [0.04]
[0.08]
[0.08]
LímiteLímite
[0.28] [0.28]
Alta
Medio
Punto nominal
Punto nominal
Baja
(Presión
(Presión
estática
estática
externa
externa
de 0.20[pulg.WG])
de 0.20[pulg.WG])
208/230V
208/230V
60Hz 60Hz
50
50
[0.32] [0.32]
[0.24] [0.24]
[0.24]
[0.12]
Medio
Baja
(Presión
(Presión
estática
estática
externa
externa
de 0.14[pulg.WG])
de 0.14[pulg.WG])
208/230V
208/230V
60Hz 60Hz
[0.16] [0.16]
Límite
[0.16]
[0.28]
Medio
Punto nominal
Punto nominal
[0.12]
Alta
Medio Medio
[0.16]
[0.16]
[0.08] [0.08]
[0.12]
Alta
SEZ-KD18NA4
SEZ-KD18NA4
SEZ-KD15NA4
SEZ-KD15NA4
(Presión
(Presión
estática
estática
externa
externa
de 0.06[pulg.WG])
de 0.06[pulg.WG])
208/230V
208/230V
60Hz60Hz
Presión estática externa [pulg.WG]
Presión estática externa [pulg.WG]
Presión
estática
externa
[pulg.WG]
Presión
estática
externa
[pulg.WG]
unto nominal
Baja
Medio
Alta
Punto nominal
Punto nominal
Alta
SEZ-KD18NA4
SEZ-KD18NA4
SEZ-KD15NA4
SEZ-KD15NA4
(Presión
(Presión
estática
estática
externa
externa
de 0.02[pulg.WG])
de 0.02[pulg.WG])
208/230V
208/230V
60Hz60Hz
[0.32]
Alta
nominal
[388]
[318]
(Presión estática externa de 0.06[pulg.WG]) 208/230V 60Hz
Alta
Baja
Baja
[0.20]
(Presión
estática externa de 0.20[pulg.WG]) 208/230V 60Hz
Límite
Límite
Baja
Alta
0
[0.04] 0 [0.04]
[282] [282]
[318] [318]
[353] [353]
[388] [388]
[424] [424]
[459] [459]
[494] [494]
[530] [530]
[565] [565]
Tasa deTasa
flujode
deflujo
aire de
[pies3/min]
aire [pies3/min]
0
0
[212]
[247]
[282]
[318]
[353]
[388]
[424]
[424]
[212]
[247]
[282]
[318]
[353]
[388]
[424]
Tasa
flujo
de aire [pies3/min]
Tasa de flujo
dede
aire
[pies3/min]
[353]
SEZ-KD12NA4
Límite
[0.08]
Baja
SEZ-KD15NA4
08/230V 60Hz
Punto nominal
MiddlePunto
Middlenominal
Alta
[0.12]
[0.12]
[0.04] [0.04]
[0.08]
Alta
[0.24]
[0.12] [0.12]
[0.20]
[0.20]
Presión
[pulg.WG]
Presiónestática
estáticaexterna
externa
[pulg.WG]
[318]
Punto nominal
Baja
Alta
[0.16]
[0.24]
[671]
[565]
[0.28] [0.28]
[0.24] [0.24]
Alta Alta
[0.20] [0.20]
[0.16] [0.16]
MedioMedio
PuntoPunto
nominal
nominal
[0.12] [0.12]
Baja Baja
Presión estática externa [pulg.WG]
[0.12]
Límite
Presión estática externa [pulg.WG]
[424]
Medio
Límite
Presión estática
estática externa
externa [pulg.WG]
Presión
[388]
Medio
[0.24]
[0.20]
[0.20]
[0.08] [0.08]
[0.16]
Límite
[0.16] [0.16]
[0.28]
[0.28]
Presión estática externa [pulg.WG]
Presión estática externa [pulg.WG]
Alta
nominal
]
n]
2]
Punto nominal
[0.16]
[0.08]
[0.24]
Límite
Límite
Presión estática externa [pulg.WG]
Presión estática externa [pulg.WG]
[0.12]
[0.20]
Presión
Presiónestática
estáticaexterna
externa[pulg.WG]
[pulg.WG]
Alta
[0.24]
Alta
0 [0.04] 0
[0.04]
[212]
[247]
[282]
[318]
[353]
[388]
[424]
[212]
[247]
[282]
[318]
[353]
[388]
[424]
Tasa
flujo
de aire [pies3/min]
0
Tasa de flujo
dede
aire
[pies3/min]
0
[141] [141] [176] [176] [212] [212] [247] [247] [282] [282] [318] [318] [353] [353]
Tasa
dede
flujo
aire [pies3/min]
Tasa de
flujo
airede[pies3/min]
[0.32]
[0.28]
[0.28]
[0.12] [0.12]
Presión estática externa [pulg.WG]
nominal
Alta
Presión estática externa [pulg.WG]
Presión
estática
externa
[pulg.WG]
Presión
estática
externa
[pulg.WG]
Límite
Alta
Límite
[0.16]
[0.28]
Presión estática externa [pulg.WG]
[0.32]
Límite
MedioMedio
Medio
Medio
Punto nominal
Punto nominal
Límite Límite
te
Límite
[0.24] [0.24]
[0.12]
[0.12]
[0.32]
[0.32]
LímiteLímite
[0.16]
[0.16]
[0.28] [0.28]
BajaBaja Baja
SEZ-KD15NA4
SEZ-KD15NA4
(Presión
(Presión
estática
estática
externa
externa
de 0.02[pulg.WG])
de 0.02[pulg.WG])
208/230V
208/230V
60Hz 60Hz
SEZ-KD12NA4
SEZ-KD12NA4
SEZ-KD12NA4
8/230V 60Hz
40
40
[0.16] [0.16]
Baja
10
10
0
0[0.04] [0.04]
[212]
[247]
[282]
[318]
[353]
[388]
[424]
[212]
[247]
[282]
[318]
[353]
[388]
[424]
Tasa
flujo
de aire [pies3/min]
0
Tasa de flujo
dede
aire
[pies3/min]
0
[353]
[141] [141] [176] [176] [212] [212] [247] [247] [282] [282] [318] [318] [353] [353]
Tasa
dede
flujo
aire [pies3/min]
Tasa de
flujo
airede[pies3/min]
ated point
[318]
Límite
Límite
Alta Alta
30
30
[0.12] [0.12]
[0.04]
[0.04]
Medio
[0.04]
]
n]
60
60
[0.24] [0.24]
50
50
[0.20] [0.20]
[0.08]
[0.08]
Alta
[0.12]
[0.08]
Presión estática externa [pulg.WG]
Presión estática externa [pulg.WG]
70
70
[0.12]
[0.28] [0.28]
[0.12]
[0.16]
externa
de 0.06[pulg.WG])
208/230V
(Presión(Presión
estática estática
externa de
0.06[pulg.WG])
208/230V
60Hz 60Hz
SEZ-KD09NA4
SEZ-KD09NA4
[0.20]
[0.20]
Presión estática externa [pulg.WG]
(Presión estática externa de 0.06[pulg.WG]) 208/230V 60Hz
8/230V 60Hz
SEZ-KD12NA4
SEZ-KD12NA4
Presión estática externa [pulg.WG]
SEZ-KD09NA4
Presión
estática
externa
[pulg.WG]
Presión
estática
externa
[pulg.WG]
E AND CORRECTED AIR FLOW
0
0
[141] [141] [176] [176] [212] [212] [247] [247] [282] [282] [318] [318] [353] [353]
Tasa
dede
flujo
aire [pies3/min]
Tasa de
flujo
airede[pies3/min]
Alta Alta
[0.24] [0.24]
[0.20] [0.20]
MedioMedio
PuntoPunto
nominal
nominal
[0.16] [0.16]
[0.12] [0.12]
[0.08] [0.08]
[0.08] [0.08]
[0.04] [0.04]
[0.04] [0.04]
Baja Baja
0
0
[318] [318]
[353] [353]
[388] [388]
[424] [424]
[459] [459]
[494] [494]
[530] [530]
[565] [565]
[600] [600]
[636] [636]
[671] [671]
0
0
[318] [318]
[353] [353]
[388] [388]
[424] [424]
[459] [459]
[494] [494]
[530] [530]
[565] [565]
[600] [600]
[636] [636]
[671] [671]
Tasa Tasa
de flujo
dede
flujo
aire
de[pies3/min]
aire [pies3/min]
Tasa Tasa
de flujo
dede
flujo
aire
de[pies3/min]
aire [pies3/min]
MITSUBISHI ELECTRIC / M-SERIES / SPECIFICATIONS / 37
SINGLE-ZONE
I SLZ System I Heat Pump
Model Name
Rated Capacity
Capacity Range
Cooling *1
Heating at 47° F *2
Heating at 17° F *3
Power Supply
Voltage
Indoor Unit
Outdoor Unit
11,100
3,400-13,300
700
920
1,460
SEER
Pints/h
15
1.2
0.84
15.4
2.3
0.77
16
4.5
0.67
Rated Capacity
Btu/h
Capacity Range
Total Input
HSPF (IV)
Rated Capacity
Rated Total Input
Maximum Capacity
Phase, Cycle, Voltage
Indoor - Outdoor S1 - S2
Indoor - Outdoor S2 - S3
MCA
Fan Motor (ECM)
Btu/h
W
Btu/h/W
Btu/h
W
Btu/h
Sound Pressure Level
External Finish
Compressor
Airflow (Cooling/Heating)
Refrigerant Control
10,900
13,600
18,000
3,100-14,100
930
3,100-22,000
1,950
280-320-390
0.23
3,100-17,100
1,180
9.6
8,300
930
8,300
1 Phase, 60Hz, 208 / 230V *4
AC 208-230V
DC ±24V
1
0.28
DRY (CFM)
280-320-350
280-320-390
WET (CFM)
dB(A)
250-290-320
29-32-38
A
F.L.A.
6,200
740
6,200
W: In.
D: In.
H: In.
Lbs.
H: In.
In.
Dimensions
A
A
F.L.A.
Model (Type)
R.L.A.
L.R.A.
CFM
12
15
0.50
DC INVERTER-driven
6.6
8.2
1,151/1,225
1,229/1,172
Linear Expansion Valve
Refrigerant Pipe Length
Connection Method
DC INVERTER-driven Twin Rotary
7.4
9.3
1,243/1,229
Reverse Cycle
dB(A)
dB(A)
46
50
49
51
Munsell No. 3Y 7.8/1.1
31-1/2
11-1/4
W: In.
D: In.
H: In.
Refrigerant Pipe
0.28
250-290-350
250-290-350
30-34-39
31-35-40
Galvanized-Steel Sheets; Grille: Munsell 6.4Y 8.9/0.4
22-7/16 (25-5/8)
22-7/16 (25-5/8)
9-1/4 (13/16)
36 (7)
19-11/16
1-1/4
Defrost Method
Sound Pressure Level at Cooling *1
Sound Pressure Level at Heating *2
External Finish Color
10,200
1,310
12,000
Select from PAC-WHS01WF-E for kumo cloud™, PAC-US444CN-1, MHK1, PAR-32MAA, or PACYT53CRAU Remote Controllers
Type
MCA
MOCP
Fan Motor (ECM)
Refrigerant
15,000
3,800-17,700
W
Weight Unit (Grille)
Drain-lift Mechanism (Included)
Field Drainpipe Size O.D.
Outdoor Unit
SLZ-KA15NA
SUZ-KA15NA
Energy Efficiency
Moisture Removal
Sensible Heat Factor
Dimension Unit (Grille)
Remote Controller
8,400
3,100-10,900
SLZ-KA12NA
SUZ-KA12NA
Total Input
Airflow at Cooling/Heating (Lo-Med-Hi)
Indoor Unit
Btu/h
Btu/h
SLZ-KA09NA
SUZ-KA09NA
21-5/8
Weight
Type
Charge
Oil
Gas Side O.D.
Liquid Side O.D.
Lbs.
66
Lbs., Oz.
Type (fl. oz.)
In.
In.
2
Height Difference (Max.)
Ft.
40
Length (Max.)
Indoor/Outdoor
Ft.
65
Flared/Flared
NOTES: Test conditions are based on AHRI 210/240.
*1. Rating conditions (cooling)-Indoor: D.B. 80º F (27º C), W.B. 67º F (19º C);
Outdoor: D.B. 95º F (35º C), W.B. 75º F (24º C).
*2. Rating conditions (heating)-Indoor: D.B. 70º F (21º C), W.B. 60º F (16º C);
Outdoor: D.B. 47º F (8º C), W.B. 43º F (6º C).
*3. Rating conditions (heating)-Indoor: D.B. 70º F (21º C), W.B. 60º F (16º C);
Outdoor: D.B. 17º F (-8º C), W.B. 15º F (-9º C).
*4. Indoor units receive power from outdoor units through field-supplied interconnected wiring.
38 / MITSUBISHI ELECTRIC / M-SERIES / SPECIFICATIONS
77
R410A
80
2, 9
NEO22 (10.8)
3/8
NEO22 (15.2)
1/2
1/4
Note: ESP at 208/230V, 60 Hz. See manual for Static Performance Curve, including at 0.02 in W.G.
Specifications are subject to change without notice.
LIMITED WARRANTY I Five years parts and seven years compressor.
MULTI-ZONE I MXZ-C I Heat Pump
Model Name
Cooling *1 Nonducted/Ducted
Indoor Unit
Power Supply
Voltage
Outdoor Unit
Rated Capacity
Btu/h
Capacity Range
Btu/h
Rated Total Input
Rated Capacity
W
Btu/h
Heating at 47° F
*2 Non-ducted/ Capacity Range
Ducted
Rated Total Input
Btu/h
Heating at 17° F Rated Capacity
*3 Non-ducted/ Maximum Capacity
Ducted
Rated Total Input
Heating at 5° F Maximum Capacity
Phase, Cycle, Voltage
Indoor - Outdoor S1 - S2
Indoor - Outdoor S2 - S3
MCA
MOCP
Fan Motor (ECM)
Airflow (Cooling/Heating)
Refrigerant Control
MXZ-3C30NA
MXZ-4C36NA-1 *6
MXZ-5C42NA
MXZ-8C48NA*8
22,000 / 23,600
28,400 / 27,400
35,400 / 34,400
40,500 / 37,500
48,000 / 48,000
12,600-22,000 / 12,60025,500
1,620 / 2,100
25,000 / 24,600
11,400-30,600 / 11,40029,400
12,600-28,400 /
12,600-27,400
2,680 / 2,840
28,600 / 27,600
11,400-36,000 /
11,400-35,000
12,600-36,400 /
12,600-34,800
3,760 / 3,940
36,000 / 34,400
11,400-43,000 /
11,400-41,400
6,000 - 43,000
6,000-48,000
4,403 / 4,112
45,000 / 41,000
4,000 / 5,050
54,000 / 54,000
7,200 - 53,600
7,200 - 54,000
W
1,750 / 1,900
2,150 / 2,220
3,020 / 3,100
3,575 / 3,463
4,220 / 4,990
Btu/h
Btu/h
W
Btu/h
14,000 / 14,000
19,600 / 19,600
2,120 / 2,230
18,200
16,000 / 15,100
21,000 / 21,000
2,120 / 2,140
18,200
22,200 / 20,300
26,600 / 26,600
3,340 / 3,450
24,000
1-phase, 60Hz, 208 / 230V *7
AC 208 / 230V
DC ±24V
22.1
24,400 / 23,000
30,500 / 29,100
2,943 / 2,869
26,000
36,600 / 36,600
36,600 / 36,600
3,720 / 4,420
32,400
31.9
40
37
52
0.4+0.4
20
28.8
2,118 / 2,542
19
22
3,885
56
51
58
54
41-9/32
189
2,3,4,5
41-11/32
13
52-11/16
269
2,3,4,5,6,7,8
8, 13
10, 9
FV50S (37.4)
FV50S (73)
A: 1/2; B,C,D,E: 3/8
1/4
5/8
3/8
230
492
82
262
131
A
A
F.L.A.
Model (Type)
R.L.A.
L.R.A.
CFM
Compressor
MXZ-3C24NA *5
22.1
25
1.90
DC INVERTER-driven Twin Rotary
12
13.7
2,068 / 1,605
1,485 / 1,640
1,365 / 1,605
Linear Expansion Valve
Defrost Method
Outdoor Unit *4
Reverse Cycle
Sound Pressure Level at
Cooling *1
Sound Pressure Level at
Heating *2
dB(A)
51
52
dB(A)
55
56
External Finish Color
Weight
No. of Units
Indoor Unit
Remote Controller
31-11/32
135
2
Type
Type
Charge
Refrigerant
Munsell No. 3.0Y 7.8 / 1.1
37-13/32
13
W: In.
D: In.
H: In.
Lbs.
Dimensions
54
137
2, 3
2, 3
Associated with the Indoor Unit
R410A
Lbs., Oz.
Oil
6, 13
Type (fl. oz.)
Refrigerant Pipe
Gas Side O.D.
Liquid Side O.D.
In.
In.
Max Refrigerant Line Length
Height Difference (Max.)
Ft.
FV50S (24.7)
A: 1/2; B: 3/8
A: 1/2; B,C: 3/8
Max. Piping Length for Each Indoor Unit
A: 1/2; B,C,D: 3/8
Max. Refrigerant
Pipe Height Difference
If IDU is Above ODU
Ft.
49
If IDU is Below ODU
Ft.
49
Connection Method
Indoor/Outdoor
NOTES: Test conditions are based on AHRI 210/240. One indoor unit is turned off during low-speed testing under the
new test conditions. Systems actually exhibit higher energy efficiencies during normal operation.
*1. Rating conditions (cooling)-Indoor: D.B. 80º F (27º C), W.B. 67º F (19º C);
Outdoor: D.B. 95º F (35º C), W.B. 75º F (24º C).
*2. Rating conditions (heating)-Indoor: D.B. 70º F (21º C), W.B. 60º F (16º C);
Outdoor: D.B. 47º F (8º C), W.B. 43º F (6º C).
*3. Rating conditions (heating)-Indoor: D.B. 70º F (21º C), W.B. 60º F (16º C);
Outdoor: D.B. 17º F (-8º C), W.B. 15º F (-9º C).
*4. Refer to pages 37-40 for Indoor Unit specifications.
Model Name
PAC-MKA30BC
Connectable No. of Indoor Units
Power Supply
Phase, Cycle, Voltage
Specifications are subject to change without notice.
LIMITED WARRANTY | Five years parts and seven years compressor.
5
1 Phase, 60Hz, 208 / 230V
W
3
Current
A
0.05
External Finish
Galvanized-Steel Sheets
Width
In.
17-2 3/32
Depth
In.
11-1/32
Height
In.
Net Weight
Refrigerant Pipe
Dimensions
*5. Data from combination of two Indoor Units 6,000 Btu/h and one 9,000 Btu/h
(non-ducted) or three 9,000 Btu/h (ducted).
*6. Data from combination of four Indoor Units 9,000 Btu/h (non-ducted and ducted).
*7. Indoor units receive power from outdoor units through field-supplied interconnected wiring.
*8. MXZ-8C48NA require branch box for operation.
PAC-MKA50BC
3
Power Input
Dimensions
164
Flared/Flared
Lbs.
PAC-MKA50BC
6-11/16
15
16
Outdoor Unit to
Branch Box
Gas (In.)
5/8
Branch Box to
Indoor Units
Gas (In.)
A,B,C: 3/8
A, B, C, D: 3/8; E: 1/2
Liquid (In.)
A,B,C: 1/4
A, B, C, D, E: 1/4
Liquid (In.)
3/8
PAC-MKA30BC
MITSUBISHI ELECTRIC / M-SERIES / SPECIFICATIONS / 39
MULTI-ZONE I MXZ-C I H2i Heat Pump
Model Name
Cooling *1 Nonducted/Ducted
Indoor Unit
Heating at 47° F
*2 Non-ducted/
Ducted
Heating at 17° F
*3 Non-ducted/
Ducted
Heating at 5° F
Power Supply
Voltage
Outdoor Unit *4
Outdoor Unit
MXZ-2C20NAHZ MXZ-3C24NAHZ MXZ-3C30NAHZ MXZ-4C36NAHZ*6 MXZ-5C42NAHZ*6 MXZ-8C48NAHZ*6
Rated Capacity
Btu/h
18,000 / 20,000
22,000 / 23,600
28,400 / 27,400
36,000 / 36,000
42,000 / 42,000
48,000 / 48,000
Capacity Range
Rated Total Input
Rated Capacity
Btu/h
W
Btu/h
6,000 - 20,000
1,334 / 1,819
22,000 / 22,000
6,000 - 23,600
1,630 / 2,360
25,000 / 24,600
12,600 - 28,400
2,272 / 2,661
28,600 / 27,600
6,000 - 36,000
2,570 / 3,180
45,000 / 45,000
6,000 - 42,000
3,130 / 3,890
48,000 / 48,000
6,000 - 48,000
4,000 / 5,050
54,000 / 54,000
Capacity Range
Btu/h
Rated Total Input
W
Rated Capacity
Btu/h
Maximum Capacity
Btu/h
Rated Total Input
W
Maximum Capacity
Btu/h
Phase, Cycle, Voltage
Indoor - Outdoor S1 - S2
Indoor - Outdoor S2 - S3
MCA
A
MOCP
A
Fan Motor (ECM)
F.L.A.
Model
(Type)
Compressor
R.L.A.
L.R.A.
Airflow
CFM
(Cooling/Heating)
Refrigerant Control
7,400 - 25,500
1,612 / 1,748
13,700 / 13,700
22,000 / 22,000
1,450 / 1,588
22,000
7,200 - 30,600
1,725 / 1,871
14,000 / 14,000
25,000 / 24, 600
1,622 / 1,635
25,000
11,400 - 36,000
7,200 - 45,000
2,096 / 2,187
3,340 / 4,250
18,000 / 16,500
34,000 / 36,000
28,600 / 27, 600
45,000 / 45,000
1,991 / 1,993
3,500 / 4,590
28,600
45,000
1-phase, 60Hz, 208 / 230V *5
AC 208 / 230V
DC ±24V
7,200 - 48,000
3,430 / 4,350
35,800 / 36,600
48,000 / 48,000
3,650 / 4,290
48,000
7200 - 54,000
4,220 / 4,990
40,000 / 43,000
54,000 / 54,000
4,340 / 5,250
54,000
29
30
DC INVERTER-driven Twin Rotary
12
28.8
2,118 / 2,542
19
22
2,118 / 2542
2,224 / 2,542
Reverse Cycle
dB(A)
54
dB(A)
58
External Finish Color
Weight
No. of Units
Remote Controller
Type
Type
Charge
Refrigerant
Max Refrigerant Line Length
2, 3
A,B: 3/8
Ft.
164
FV50S (37.4)
A: 1/2; B,C: 3/8
230
131
Indoor/Outdoor
164
Flared/Flared
NOTES: Test conditions are based on AHRI 210/240. One indoor unit is turned off during low-speed testing under the
new test conditions. Systems actually exhibit higher energy efficiencies during normal operation.
*1. Rating conditions (cooling)-Indoor: D.B. 80º F (27º C), W.B. 67º F (19º C);
Outdoor: D.B. 95º F (35º C), W.B. 75º F (24º C).
*2. Rating conditions (heating)-Indoor: D.B. 70º F (21º C), W.B. 60º F (16º C);
Outdoor: D.B. 47º F (8º C), W.B. 43º F (6º C).
*3. Rating conditions (heating)-Indoor: D.B. 70º F (21º C), W.B. 60º F (16º C);
Outdoor: D.B. 17º F (-8º C), W.B. 15º F (-9º C).
PAC-MKA30BC
Phase, Cycle, Voltage
*4. Refer to pages 35-39 for Indoor Unit specifications.
*5. Indoor units receive power from outdoor units through field-supplied interconnected wiring.
*6. MXZ-4C36NAHZ, MXZ-5C42NAHZ and MXZ-8C48NAHZ require branch box for operation.
Specifications are subject to change without notice.
LIMITED WARRANTY | Five years parts and seven years compressor.
PAC-MKA50BC
3
5
1 Phase, 60Hz, 208 / 230V
Power Input
W
3
Current
A
0.05
External Finish
Galvanized-Steel Sheets
Width
In.
17-2 3/32
Depth
In.
11-1/32
Height
In.
Gas (In.)
492
262
Connection Method
FV50S (73)
5/8
3/8
82
49
Branch Box to
Indoor Units
2,3,4,5,6,7,8
10, 9
A: 1/2; B,C: 3/8
1/4
Ft.
Gas (In.)
2,3,4
FV50S (24.7)
In.
In.
If IDU is Below ODU
Outdoor Unit to
Branch Box
52-11/16
276
2,3,4,5
6, 13
Type
(fl. oz.)
49
Refrigerant Pipe
Dimensions
41-11/32
2, 3
Ft.
Lbs.
54
189
If IDU is Above ODU
Net Weight
54
41-9/32
187
2
Max. Refrigerant
Pipe Height Difference
Dimensions
53
13
Max. Piping Length for Each Indoor Unit
Model Name
51
37-13/32
Lbs., Oz.
Gas Side O.D.
Liquid Side O.D.
Height Difference
(Max.)
Connectable No. of Indoor Units
50
Associated with the Indoor Unit
R410A
Oil
Refrigerant Pipe
49
Munsell No. 3.0Y 7.8 / 1.1
W: In.
D: In.
H: In.
Lbs.
Dimensions
Indoor Unit
3,885 / 3,885
Linear Expansion Valve
Defrost Method
Sound Pressure
Level at Cooling *1
Sound Pressure
Level at Heating *2
Power Supply
42
52
0.4+0.4
40
1.90
PAC-MKA50BC
6-11/16
15
Only a single lineset is
needed from the outdoor
unit to branch box.
Branch Boxes: (At least
one branch box required)
16
5/8
Liquid (In.)
3/8
A,B,C: 3/8
A, B, C, D: 3/8; E: 1/2
(In.) on compressor.
A,B,C: 1/4Five-year warranty on parts.
A, B, C, D, E: 1/4
LIMITED WARRANTY | Seven-year Liquid
warranty
40 / MITSUBISHI ELECTRIC / M-SERIES / SPECIFICATIONS
PAC-MKA30BC
MITSUBISHI ELECTRIC / M-SERIES / SPECIFICATIONS / 40
MULTI-ZONE I MSZ Indoor Units I Heat Pump
(FOR MXZ-C OUTDOOR UNITS)
Model Name
Indoor Unit
MSZ-FH06NA
MSZ-FH09NA
MSZ-FH12NA
MSZ-FH15NA
MSZ-FH18NA2
Cooling *1
Rated Capacity
Btu/h
6,000
9,000
12,000
15,000
17,200
Heating at
47° F *2
Rated Capacity
Btu/h
8,700
10,900
13,600
18,000
20,300
Power Supply
Voltage
Phase, Cycle, Voltage
AC 208 / 230V
Indoor - Outdoor S2 - S3
DC ±24V
MCA
A
Blower Motor
F.L.A.
DRY
(CFM)
Fan
1-phase, 60Hz, 208 / 230V *3
Indoor - Outdoor S1 - S2
Airflow at Cooling
(Quiet-Lo-Med-HiWET
Super Hi)*1
(CFM)
Airflow at Heating
DRY
(Quiet-Lo-Med-Hi(CFM)
Super Hi) *2
1.0
0.76
0.67
137-167-221-304-381
137-167-221-304-381
137-167-221-304-398
225-262-304-355-411
225-262-304-355-459
117-143-190-261-328
117-143-190-261-328
117-143-190-261-342
194-225-261-305-354
194-225-261-305-395
140-167-225-325-437
140-167-225-325-437
140-167-225-325-454
201-254-317-394-497
201-254-317-394-514
Sound Pressure Level at Cooling
(Quiet-Lo-Med-Hi-Super Hi) *1
dB(A)
20-23-29-36-40
20-23-29-36-40
21-24-29-36-41
27-31-35-39-47
20-23-29-36-40
Sound Pressure Level at Heating
(Quiet-Lo-Med-Hi-Super Hi) *2
dB(A)
20-24-29-36-42
20-24-29-36-42
21-24-29-36-42
25-29-34-39-46
20-24-29-36-42
External Finish Color
Munsell 1.0Y 9.2 / 0.2
W: In.
Dimension Unit
36-7/16
D: In.
9-3/16
H: In.
12(+11/16)
Weight Unit
Lbs.
29
Field Drainpipe Size O.D.
In.
5/8
Remote
Controller
Type
Refrigerant
Type
Refrigerant Pipe
Connection
Method
Select from PAC-WHS01WF-E for kumo cloud™, PAC-US444CN-1, MHK1, PAR-31MAA, or PAC-YT53CRAU Remote Controllers
R410A
Gas Side O.D.
In.
Liquid Side O.D.
In.
3/8
Indoor/Outdoor
1/2
1/4
Flared/Flared
NOTES: Test conditions are based on AHRI 210/240.
NOTES: Test conditions are based on AHRI 210/240.
*1. Rating conditions (cooling)-Indoor: D.B. 80º F (27º C), W.B. 67º F (19º C); Outdoor: D.B. 95º F (35º C), W.B. 75º F (24º C).
*2. Rating conditions (heating)-Indoor: D.B. 70º F (21º C), W.B. 60º F (16º C); Outdoor: D.B. 47º F (8º C), W.B. 43º F (6º C).
*3. Rating conditions (heating)-Indoor: D.B. 70º F (21º C), W.B. 60º F (16º C); Outdoor: D.B. 17º F (-8º C), W.B. 15º F (-9º C).
Specifications are subject to change without notice.
LIMITED WARRANTY I Five years parts and seven years compressor.
For data on specific indoor unit combinations, visit www.mitsubishipro.com/multizone.
MITSUBISHI ELECTRIC / M-SERIES / SPECIFICATIONS / 41
MULTI-ZONE I MSZ Indoor Units I Heat Pump
(FOR MXZ-C OUTDOOR UNITS)
Model Name
Indoor Unit
MSZ-GL06NA-U1
MSZ-GL09NA-U1
MSZ-GL12NA-U1
MSZ-GL15NA-U1
MSZ-GL18NA-U1
MSZ-GL24NA-U1
Cooling *1
Rated Capacity
Btu/h
6,000
9,000
12,000
14,000
17,200
22,400
Heating at
47° F *2
Rated Capacity
Btu/h
7,200
10,900
14,400
18,000
21,600
27,600
Power Supply
Phase, Cycle, Voltage
0.67
0.76
Voltage
1-phase, 60Hz, 208 / 230V *3
Indoor - Outdoor S1 - S2
AC 208 / 230V
Indoor - Outdoor S2 - S3
DC ±24V
MCA
A
Blower Motor
F.L.A.
1.0
0.76
DRY (CFM) 145-170-237-321-399
Airflow at Cooling
(Quiet-Lo-Med-HiWET
Super Hi)*1
109-134-201-286-364
(CFM)
Fan
Airflow at Heating
DRY
(Quiet-Lo-Med-Hi(CFM)
Super Hi) *2
145-170-237-321-399
205-272-335-420-533
259-333-416-523-646
388-469-544-628-738
109-134-201-286-364
170-237-300-385-498
233-300-375-470-581
347-420-487-562-661
145-170-237-321-406
145-170-237-321-406
205-247-304-367-463
296-384-469-563-646
388-469-544-628-738
Sound Pressure Level at Cooling
(Quiet-Lo-Med-Hi-Super Hi) *1
dB(A)
19-22-30-37-43
19-22-30-37-45
26-32-38-44-49
28-33-38-44-49
34-41-45-49-53
Sound Pressure Level at Heating
(Quiet-Lo-Med-Hi-Super Hi) *2
dB(A)
19-22-30-37-43
19-22-30-37-43
26-30-35-40-46
28-33-38-43-48
32-41-45-49-52
External Finish Color
Dimension Unit
Munsell 1.0Y 9.2 / 0.2
W: In.
31-7/16
36-5/16
43-5/16
D: In.
9-1/8
9-13/16
9-3/8
H: In.
11-5/8
12
12-13/16
Weight Unit
Lbs.
22
28
37
Field Drainpipe Size O.D.
In.
5/8
Remote
Controller
Type
Select from PAC-WHS01WF-E for kumo cloud™, PAC-US444CN-1, MHK1, PAR-31MAA, or PAC-YT53CRAU Remote Controllers
Refrigerant
Type
R410A
Refrigerant Pipe
Connection
Method
Gas Side O.D.
In.
Liquid Side O.D.
In.
3/8
Indoor/Outdoor
1/2
1/4
5/8
3/8
Flared/Flared
NOTES: Test conditions are based on AHRI 210/240.
*1. Rating conditions (cooling)-Indoor: D.B. 80º F (27º C), W.B. 67º F (19º C); Outdoor: D.B. 95º F (35º C), W.B. 75º F (24º C).
*2. Rating conditions (heating)-Indoor: D.B. 70º F (21º C), W.B. 60º F (16º C); Outdoor: D.B. 47º F (8º C), W.B. 43º F (6º C).
*3. Indoor units receive power from outdoor units through field-supplied wiring.
Specifications are subject to change without notice.
LIMITED WARRANTY I Seven-year warranty on compressor. Five-year warranty on parts.
For data on specific indoor unit combinations, visit www.mitsubishipro.com/multizone.
42 / MITSUBISHI ELECTRIC / M-SERIES / SPECIFICATIONS
MITSUBISHI ELECTRIC / M-SERIES / SPECIFICATIONS / 42
SEZ Ducted Indoor Unit I Heat Pump
(FOR MXZ-C OUTDOOR UNITS)
SEZ-KD09NA4
SEZ-KD12NA4
SEZ-KD15NA4
SEZ-KD18NA4
Cooling *1
Model Name
Rated Capacity
Indoor Unit
Btu/h
8,100
11,500
14,100
17,200
Heating at 47˚ F *2
Rated Capacity
Btu/h
10,900
13,600
18,000
21,600
Power Supply
Phase, Cycle, Voltage
1-Phase, 60Hz, 208 / 230V *4
Indoor - Outdoor S1-S2
Voltage
AC 208-230V
Indoor - Outdoor S2-S3
MCA
Fan
DC ±24V
A
1.0
Blower Motor (ECM)
F.L.A.
0.51
0.57
Airflow at Cooling/Heating
(Lo-Med-Hi)
CFM
194-247-317
247-317-388
External Static Pressure *3
In. W.G.
Sound Pressure Levels (Lo-Med-Hi)
dB(A)
0.74
353-441-529
0.02-0.06-0.14-0.20
23-26-30
23-28-33
External Finish
30-34-37
Dimension
31-1/8
39
D: In.
27-9/16
H: In.
7-7/8
Weight
Lbs.
Drain-lift Mechanism (Included)
H: In.
21-11/16
In.
1-1/4
Field Drainpipe Size O.D.
Refrigerant
Refrigerant Pipe
30-34-38
Galvanized-steel Sheets
W: In.
Remote Controller
423-529-635
42
50
Type
Gas Side O.D.
54
62
Select from PAC-WHS01WF-E for kumo cloud™, PAC-US444CN-1, MHK1, PAR-32MAA, or PAC-YT53CRAU Remote
Controllers
Type
Liquid Side O.D.
46-7/8
R410A
In.
3/8
1/2
1/4
Connection Method
Flared/Flared
vvConnection Method
Flared/Flared
NOTES: Test conditions are based on AHRI 210/240.
*1. Rating conditions (cooling)-Indoor: D.B. 80º F (26.7º C), W.B. 67º F (19.4º C); Outdoor: D.B. 95º F (35º C), W.B. 75º F (23.9º C).
*2. Rating conditions (heating)-Indoor: D.B. 70º F (21.1º C), W.B. 60º F (15.6º C); Outdoor: D.B. 47º F (8.3º C), W.B. 43º F (6.1º C).
*3. External static pressure is factory set to 0.06" W.G. Adjustable via remote controller.
*4. Indoor units receive power from outdoor units through field supplied interconnected wiring.
Specifications are subject to change without notice.
LIMITED WARRANTY I Five years parts and seven years compressor.
MITSUBISHI ELECTRIC / M-SERIES / SPECIFICATIONS / 43
MVZ Multi-Position Air-Handling Unit I Heat Pump
(FOR MXZ-C OUTDOOR UNITS)
MVZ-A12AA4
MVZ-A18AA4
MVZ-A24AA4
MVZ-A30AA4
MVZ-A36AA4
Cooling *1
Model Name
Rated Capacity
Indoor Unit
Btu/h
12,000
18,000
24,000
30,000
36,000
Heating at 47° F *2
Rated Capacity
Btu/h
13,500
20,000
27,000
34,000
40,000
Power Supply
Phase, Cycle, Voltage
613-744-875
767-931-1095
32-36-40
35-39-43
1-phase, 60Hz, 208 / 230V
Indoor - Outdoor S1-S2
Voltage
AC 208-230V
Indoor - Outdoor S2-S3
MCA
Fan
±24VDC
A
Airflow at Cooling/Heating
(Lo-Med-Hi)
CFM
External Static Pressure *3
In. W.G.
Sound Pressure Level at Cooling/Heating
(Lo-Med-Hi) *1
dB(A)
1.0
280-340-400
410-497-585
0.30-0.50-0.80
27-31-35
28-32-36
External Finish Color
W: In.
50-1/4
54-1/4
D: In.
17
54-1/4
H: In.
Weight Unit
Refrigerant Pipe
Connection Method
30-34-38
High-gloss polyester powder coated
Dimension Unit
Refrigerant
515-625-735
21-5/8
Lbs.
113
Type
141
R410A
Gas Side O.D.
In.
1/2
5/8
Liquid Side O.D.
In.
1/4
3/8
Indoor/Outdoor
Flared/Flared
NOTES: Test conditions are based on AHRI 210/240.
*1. Rating conditions (cooling)-Indoor: D.B. 80º F (26.7º C), W.B. 67º F (19.4º C); Outdoor: D.B. 95º F (35º C), W.B. 75º F (23.9º C).
*2. Rating conditions (heating)-Indoor: D.B. 70º F (21.1º C), W.B. 60º F (15.6º C); Outdoor: D.B. 47º F (8.3º C), W.B. 43º F (6.1º C).
*3. External static pressure is factory set to 0.05" W.G. at factory shipment.
Specifications are subject to change without notice.
LIMITED WARRANTY I Five years parts and seven years compressor.
44 / MITSUBISHI ELECTRIC / M-SERIES / SPECIFICATIONS
MVZ MULTI-POSITION PERFORMANCE CURVES
MVZ-A12AA4
• Vertical, Horizontal Right, Horizontal Left
75
[0.30]
Static pressure (Pa)[in.WG]
• Downflow
External static pressure 0.30 [in.WG] (75Pa) 208/230V 60Hz
100
[0.40]
Middle
50
[0.20]
External static pressure 0.30 [in.WG] (75Pa) 208/230V 60Hz
75
[0.30]
High
Static pressure (Pa)[in.WG]
100
[0.40]
Low
25
[0.10]
High
50
[0.20]
Middle
Low
25
[0.10]
0
[0] 7
[247]
10
[353]
0
[0] 7
[247]
14
[494]
10
[353]
Airflow rate (m3/min)[cfm]
External static pressure 0.50 [in.WG] (125Pa) 208/230V 60Hz
External static pressure 0.50 [in.WG] (125Pa) 208/230V 60Hz
125
[0.50]
125
[0.50]
Static pressure (Pa)[in.WG]
150
[0.60]
High
High
Static pressure (Pa)[in.WG]
150
[0.60]
14
[494]
Airflow rate (m3/min)[cfm]
100
[0.40]
Middle
100
[0.40]
Middle
75
[0.30]
Low
75
[0.30]
50
[0.20]
Low
50
[0.20] 7
[247]
10
[353]
25
[0.10] 7
[247]
14
[494]
10
[353]
Airflow rate (m3/min)[cfm]
225
[0.90]
External static pressure 0.80 [in.WG] (200Pa) 208/230V 60Hz
150
[0.60]
Middle
125
[0.50]
75
[0.30] 7
[247]
Airflow rate (m3/min)[cfm]
14
[494]
High
175
[0.70]
150
[0.60]
Middle
125
[0.50]
100
[0.40]
Low
10
[353]
External static pressure 0.80 [in.WG] (200Pa) 208/230V 60Hz
200
[0.80]
High
175
[0.70]
100
[0.40]
225
[0.90]
Static pressure (Pa)[in.WG]
Static pressure (Pa)[in.WG]
200
[0.80]
14
[494]
Airflow rate (m3/min)[cfm]
75
[0.30] 7
[247]
Low
10
[353]
14
[494]
Airflow rate (m3/min)[cfm]
MITSUBISHI ELECTRIC / M-SERIES / SPECIFICATIONS / 45
MVZ MULTI-POSITION PERFORMANCE CURVES
MVZ-A18AA4
• Vertical, Horizontal Right, Horizontal Left
100
[0.40]
75
[0.30]
100
[0.40]
Middle
50
[0.20]
External static pressure 0.30 [in.WG] (75Pa) 208/230V 60Hz
75
[0.30]
High
Static pressure (Pa)[in.WG]
Static pressure (Pa)[in.WG]
• Downflow
External static pressure 0.30 [in.WG] (75Pa) 208/230V 60Hz
Low
High
50
[0.20]
Middle
Low
25
[0.10]
25
[0.10]
0
[0] 10
[353]
15
[530]
0
[0] 10
[353]
20
[706]
15
[530]
Airflow rate (m3/min)[cfm]
150
[0.60]
External static pressure 0.50 [in.WG] (125Pa) 208/230V 60Hz
External static pressure 0.50 [in.WG] (125Pa) 208/230V 60Hz
High
High
Static pressure (Pa)[in.WG]
Static pressure (Pa)[in.WG]
150
[0.60]
125
[0.50]
125
[0.50]
20
[706]
Airflow rate (m3/min)[cfm]
100
[0.40]
Middle
75
[0.30]
100
[0.40]
Middle
75
[0.30]
Low
50
[0.20]
Low
50
[0.20]
10
[353]
15
[530]
25
[0.10] 10
[353]
20
[706]
15
[530]
225
[0.90]
External static pressure 0.80 [in.WG] (200Pa) 208/230V 60Hz
External static pressure 0.80 [in.WG] (200Pa) 208/230V 60Hz
200
[0.80]
High
175
[0.70]
150
[0.60]
Middle
125
[0.50]
100
[0.40]
225
[0.90]
Static pressure (Pa)[in.WG]
Static pressure (Pa)[in.WG]
200
[0.80]
20
[706]
Airflow rate (m3/min)[cfm]
Airflow rate (m3/min)[cfm]
High
175
[0.70]
150
[0.60]
Middle
125
[0.50]
100
[0.40]
Low
Low
75
[0.30] 10
[353]
15
[530]
Airflow rate (m3/min)[cfm]
46 / MITSUBISHI ELECTRIC / M-SERIES / SPECIFICATIONS
20
[706]
75
[0.30] 10
[353]
15
[530]
Airflow rate (m3/min)[cfm]
20
[706]
MVZ MULTI-POSITION PERFORMANCE CURVES
MVZ-A24AA4
• Vertical, Horizontal Right, Horizontal Left
100
[0.40]
75
[0.30]
100
[0.40]
50
[0.20]
Middle
Low
25
[0.10]
15
[530]
20
[706]
Airflow rate
150
[0.60]
Middle
Low
15
[530]
(m3/min)[cfm]
20
[706]
24
[847]
Airflow rate (m3/min)[cfm]
External static pressure 0.50 [in.WG] (125Pa) 208/230V 60Hz
150
[0.60]
External static pressure 0.50 [in.WG] (125Pa) 208/230V 60Hz
125
[0.50]
125
[0.50]
High
High
Static pressure (Pa)[in.WG]
Static pressure (Pa)[in.WG]
0
[0] 13
[459]
24
[847]
High
50
[0.20]
25
[0.10]
0
[0] 13
[459]
External static pressure 0.30 [in.WG] (75Pa) 208/230V 60Hz
75
[0.30]
High
Static pressure (Pa)[in.WG]
Static pressure (Pa)[in.WG]
• Downflow
External static pressure 0.30 [in.WG] (75Pa) 208/230V 60Hz
100
[0.40]
Middle
100
[0.40]
Middle
75
[0.30]
Low
75
[0.30]
50
[0.20]
Low
50
[0.20] 13
[459]
15
[530]
20
[706]
25
[0.10] 13
[459]
24
[847]
15
[530]
225
[0.90]
External static pressure 0.80 [in.WG] (200Pa) 208/230V 60Hz
Static pressure (Pa)[in.WG]
Static pressure (Pa)[in.WG]
External static pressure 0.80 [in.WG] (200Pa) 208/230V 60Hz
High
150
[0.60]
Middle
125
[0.50]
75
[0.30] 13
[459]
24
[847]
200
[0.80]
175
[0.70]
100
[0.40]
225
[0.90]
High
200
[0.80]
20
[706]
Airflow rate (m3/min)[cfm]
Airflow rate (m3/min)[cfm]
175
[0.70]
150
[0.60]
Middle
125
[0.50]
100
[0.40]
Low
Low
15
[530]
20
[706]
Airflow rate (m3/min)[cfm]
22
[777]
75
[0.30] 13
[459]
15
[530]
20
[706]
22
[777]
Airflow rate (m3/min)[cfm]
MITSUBISHI ELECTRIC / M-SERIES / SPECIFICATIONS / 47
MVZ MULTI-POSITION PERFORMANCE CURVES
MVZ-A30AA4
• Vertical, Horizontal Right, Horizontal Left
100
[0.40]
• Downflow
External static pressure 0.30 [in.WG] (75Pa) 208/230V 60Hz
100
[0.40]
External static pressure 0.30 [in.WG] (75Pa) 208/230V 60Hz
High
High
75
[0.30]
Static pressure (Pa)[in.WG]
Static pressure (Pa)[in.WG]
75
[0.30]
Middle
50
[0.20]
Low
50
[0.20]
Middle
Low
25
[0.10]
25
[0.10]
0
[0] 15
[530]
20
[706]
25
[883]
0
[0] 15
[530]
29
[1024]
20
[706]
Airflow rate (m3/min)[cfm]
150
[0.60]
25
[883]
29
[1024]
Airflow rate (m3/min)[cfm]
External static pressure 0.50 [in.WG] (125Pa) 208/230V 60Hz
150
[0.60]
External static pressure 0.50 [in.WG] (125Pa) 208/230V 60Hz
High
125
[0.50]
High
Static pressure (Pa)[in.WG]
Static pressure (Pa)[in.WG]
125
[0.50]
100
[0.40]
Middle
75
[0.30]
100
[0.40]
Middle
75
[0.30]
Low
Low
50
[0.20]
50
[0.20]
25
[0.10]
15
[530]
20
[706]
25
[883]
25
[0.10] 15
[530]
29
[1024]
20
[706]
225
[0.90]
25
[883]
28
[989]
Airflow rate (m3/min)[cfm]
Airflow rate (m3/min)[cfm]
External static pressure 0.80 [in.WG] (200Pa) 208/230V 60Hz
225
[0.90]
External static pressure 0.80 [in.WG] (200Pa) 208/230V 60Hz
High
200
[0.80]
High
175
[0.70]
Static pressure (Pa)[in.WG]
Static pressure (Pa)[in.WG]
200
[0.80]
150
[0.60]
Middle
125
[0.50]
100
[0.40]
75
[0.30]
15
[530]
175
[0.70]
150
[0.60]
125
[0.50]
100
[0.40]
Low
20
[706]
25
[883]
Airflow rate (m3/min)[cfm]
48 / MITSUBISHI ELECTRIC / M-SERIES / SPECIFICATIONS
29
[1024]
Middle
75
[0.30] 15
[530]
Low
20
[706]
Airflow rate (m3/min)[cfm]
25
[883]
27
[953]
MVZ MULTI-POSITION PERFORMANCE CURVES
MVZ-A36AA4
• Vertical, Horizontal Right, Horizontal Left
100
[0.40]
• Downflow
External static pressure 0.30 [in.WG] (75Pa) 208/230V 60Hz
125
[0.50]
High
100
[0.40]
75
[0.30]
High
Static pressure (Pa)[in.WG]
Static pressure (Pa)[in.WG]
External static pressure 0.30 [in.WG] (75Pa) 208/230V 60Hz
Middle
50
[0.20]
Low
75
[0.30]
Middle
50
[0.20]
Low
25
[0.10]
25
[0.10]
0
[0] 19
20
[671] [706]
25
[883]
30
[1059]
0
[0] 19
20
[671] [706]
33
[1165]
25
[883]
Airflow rate (m3/min)[cfm]
150
[0.60]
30
[1059]
32
[1130]
Airflow rate (m3/min)[cfm]
External static pressure 0.50 [in.WG] (125Pa) 208/230V 60Hz
175
[0.70]
External static pressure 0.50 [in.WG] (125Pa) 208/230V 60Hz
150
[0.60]
High
High
100
[0.40]
Static pressure (Pa)[in.WG]
Static pressure (Pa)[in.WG]
125
[0.50]
Middle
125
[0.50]
100
[0.40]
Middle
75
[0.30]
Low
75
[0.30]
50
[0.20]
Low
50
[0.20] 19
20
[671] [706]
25
[883]
30
[1059]
25
[0.10] 19
20
[671] [706]
32
[1130]
25
[883]
225
[0.90]
30
[1059]
32
[1130]
Airflow rate (m3/min)[cfm]
Airflow rate (m3/min)[cfm]
External static pressure 0.80 [in.WG] (200Pa) 208/230V 60Hz
200
[0.80]
External static pressure 0.60 [in.WG] (150Pa) 208/230V 60Hz
High
200
[0.80]
175
[0.70]
175
[0.70]
150
[0.60]
150
[0.60]
Static pressure (Pa)[in.WG]
Static pressure (Pa)[in.WG]
High
Middle
125
[0.50]
100
[0.40]
75
[0.30]
19
20
[671] [706]
125
[0.50]
100
[0.40]
75
[0.30]
Low
25
[883]
Airflow rate (m3/min)[cfm]
30
[1059]
32
[1130]
Middle
50
[0.20]
19
20
[671] [706]
Low
25
[883]
30
[1059]
32
[1130]
Airflow rate (m3/min)[cfm]
MITSUBISHI ELECTRIC / M-SERIES / SPECIFICATIONS / 49
MFZ Floor-mounted Indoor Unit I Heat Pump
(FOR MXZ-C OUTDOOR UNITS)
Model Name
Indoor Unit
MFZ-KA09NA
MFZ-KA12NA
MFZ-KA18NA
Cooling *1
Rated Capacity
Btu/h
9,000
12,000
18,000
Heating at 47° F *2
Rated Capacity
Btu/h
10,900
14,400
21,600
Power Supply
Voltage
Phase, Cycle, Voltage
AC 208 / 230V
Indoor - Outdoor S2 - S3
DC ±24V
MCA
Airflow at Cooling/Heating
(Lo-Med-Hi)
Fan
1-phase, 60Hz, 208 / 230V *3
Indoor - Outdoor S1 - S2
Airflow at Heating
(Lo-Med-Hi-Super Hi) *2
Sound Pressure Level at Cooling
(Lo-Med-Hi-Super Hi) *1
Sound Pressure Level at Heating
(Lo-Med-Hi-Super Hi) *2
A
DRY (CFM)
1
169-205-251-314
177-215-261-321
WET (CFM)
163-197-241-303
170-207-252-309
241-269-313-379
(CFM)
177-198-219-332
184-201-219-335
261-275-297-434
dB(A)
25-30-35-40
26-31-36-41
35-38-42-46
dB(A)
25-30-35-40
28-31-36-41
35-38-42-47
External Finish Color
Munsell No. 1.0Y 9.2/0.2
W: In.
Dimension Unit
Weight Unit
Field Drainpipe Size O.D.
Remote Controller
Type
Refrigerant
Type
Refrigerant Pipe
Connection Method
251-279-325-394
27-9/16
D: In.
7-7/8
H: In.
23-5/8
Lbs.
32
In.
5/8
Select from PAC-WHS01WF-E for kumo cloud™, PAC-US444CN-1,
MHK1, PAR-32MAA, or PAC-YT53CRAU Remote Controllers
R410A
Gas Side O.D.
In.
Liquid Side O.D.
In.
3/8
Indoor/Outdoor
NOTES: Test conditions are based on AHRI 210/240.
*1. Rating conditions (cooling)-Indoor: D.B. 80º F (26.7º C), W.B. 67º F (19.4º C); Outdoor: D.B. 95º F (35º C), W.B. 75º F (23.9º C).
*2. Rating conditions (heating)-Indoor: D.B. 70º F (21.1º C), W.B. 60º F (15.6º C); Outdoor: D.B. 47º F (8.3º C), W.B. 43º F (6.1º C).
*3. Indoor units receive power from outdoor units through field supplied interconnected wiring.
Specifications are subject to change without notice.
LIMITED WARRANTY I Five years parts and seven years compressor.
Presently, there is no 1:1 system with the MFZ indoor unit.
50 / MITSUBISHI ELECTRIC / M-SERIES / SPECIFICATIONS
1/2
1/4
Flared/Flared
SLZ Ceiling-recessed Indoor Unit I Heat Pump
(FOR MXZ-C OUTDOOR UNITS)
Model Name
Indoor Unit
SLZ-KA09NA
SLZ-KA12NA
SLZ-KA15NA
Cooling *1
Rated Capacity
Btu/h
8,400
11,100
15,000
Heating at 47° F *2
Rated Capacity
Btu/h
10,900
13,600
18,000
Power Supply
Voltage
Phase, Cycle, Voltage
AC 208 / 230V
Indoor - Outdoor S2 - S3
DC ±24V
MCA
Fan Motor (ECM)
Fan
1-phase, 60Hz, 208 / 230V *3
Indoor - Outdoor S1 - S2
Airflow at Cooling/
Heating (Lo-Med-Hi)
Sound Pressure Level (Lo-Med-Hi) *2
External Finish Color
Dimension Unit (Grille)
A
1
F.L.A.
0.23
0.28
0.28
DRY (CFM)
280-320-350
280-320-390
280-320-390
WET (CFM)
250-290-320
250-290-350
250-290-350
dB(A)
29-32-38
30-34-39
31-35-40
Unit/Grille
Galvanized-steel Sheets/Munsell 6.4Y 8.9 / 0.4
W: In.
22-7/16 (25-5/8)
D: In.
22-7/16 (25-5/8)
H: In.
9-1/4 (13/16)
Weight Unit (Grille)
Lbs.
36 (7)
Drain-lift Mechanism (Included)
H: In.
19-11/16
In.
1-1/4
Type
Select from PAC-WHS01WF-E for kumo cloud™, PAC-US444CN-1,
MHK1, PAR-32MAA, or PAC-YT53CRAU Remote Controllers
Field Drainpipe Size O.D.
Remote Controller
Refrigerant
Refrigerant Pipe
Type
R410
Gas Side O.D.
In.
Liquid Side O.D.
In.
3/8
1/2
1/4
Connection Method
Indoor/Outdoor
Flared/Flared
Connection Method
Indoor/Outdoor
Flared/Flared
NOTES: Test conditions are based on AHRI 210/240.
*1. Rating conditions (cooling)-Indoor: D.B. 80º F (26.7º C), W.B. 67º F (19.4º C); Outdoor: D.B. 95º F (35º C), W.B. 75º F (23.9º C).
*2. Rating conditions (heating)-Indoor: D.B. 70º F (21.1º C), W.B. 60º F (15.6º C); Outdoor: D.B. 47º F (8.3º C), W.B. 43º F (6.1º C).
*3. Indoor units receive power from outdoor units through field supplied interconnected wiring.
Specifications are subject to change without notice.
LIMITED WARRANTY I Five years parts and seven years compressor.
MITSUBISHI ELECTRIC / M-SERIES / SPECIFICATIONS / 51
ADDITIONAL M-SERIES INFORMATION
PORT ADAPTERS PART NUMBERS
PORT ADAPTER GUIDE
MAC-A454JP-E
3/8" x 1/2"
MAC-A455JP-E
1/2" x 3/8"
MAC-A456JP-E
1/2" x 5/8"
PAC-SG76RJ-E
3/8" x 5/8"
PAC-493PL
1/4" x 3/8"
PORT
GAS
AVAILABLE INDOOR UNITS
MSZ Wall-mounted
MSZ-GL06NA-U1
MSZ-GL09NA-U1
MSZ-GL12NA-U1
MSZ-GL15NA-U1
MSZ-GL18NA-U1
MSZ-GL24NA-U1
MSZ-FH06NA
MSZ-FH09NA
MSZ-FH12NA
MSZ-FH15NA
MSZ-FH18NA2
MFZ Floor-standing
MFZ-KA09NA
MFZ-KA12NA
MFZ-KA18NA
MVZ Multi-position
MVZ-A12AA4
MVZ-A18AA4
MVZ-A24AA4
MVZ-A30AA4
MVZ-A36AA4
PLA Ceiling-recessed
PLA-A12BA6
PLA-A18BA6
PLA-A24BA6
PLA-A30BA6
PLA-A36BA6
PCA Ceiling-suspended
PCA-A24KA6
SLZ Ceiling-recessed
LIQUID
A; B
MXZ-2B20NA-1
3/8"
1/4"
A
B; C
MXZ-3C24NA
1/2"
3/8"
1/4"
1/4"
A
B; C
MXZ-3C30NA
1/2"
3/8"
1/4"
1/4"
A
B; C; D
MXZ-4C36NA
1/2"
3/8"
1/4"
1/4"
A
B; C; D; E
MXZ-5C42NA
1/2"
3/8"
1/4"
1/4"
A; B
MXZ-2C20NAHZ
3/8"
1/4"
A
B; C
MXZ-3C24NAHZ
1/2"
3/8"
1/4"
1/4"
A
B; C
MXZ-3C30NAHZ
1/2"
3/8"
1/4"
1/4"
THE FOLLOWING MXZ UNITS
MUST UTILIZE AT LEAST ONE
BRANCH BOX
BRANCH BOXES
PORT
GAS
LIQUID
PAC-MKA30BC [3-Port]
A; B; C
3/8"
1/4"
3/8"
1/4"
E
1/2"
1/4'
5/8" gas x 3/8" liquid
3/8" gas x 1/4" liquid
3/8" gas x 1/4" liquid
1/2" gas x 1/4" liquid
3/8" gas x 1/4" liquid
3/8" gas x 1/4" liquid
1/2" gas x 1/4" liquid
1/2" gas x 1/4" liquid
5/8" gas x 3/8" liquid
5/8" gas x 3/8" liquid
5/8" gas x 3/8" liquid
MODELS
MXZ-2B20NA-1
MXZ-3C24/3C30/4C36/5C42NA
Maximum
** Select the branch box or boxes needed for your
application.
CONDITIONS
95° F D.B., 71° F W.B.
MXZ-2C20/3C24/3C30NAHZ
MUZ/Y-GL/D
** Compare indoor unit lineset sizes to branch box or outdoor
unit port sizes.
MUZ-FH
MXZ-8C48NA
90° F D.B., 73° F W.B.
MXZ-4C36/54C42/8C48NAHZ
Cooling
MUZ/Y-GL/D
** Adapt lineset size with appropriate port adapter from above
list.
52 / MITSUBISHI ELECTRIC / M-SERIES / SPECIFICATIONS
1/2" gas x 1/4" liquid
1/2" gas x 1/4" liquid
5/8" gas x 3/8" liquid
5/8" gas x 3/8" liquid
5/8" gas x 3/8" liquid
SUZ
** Check the lineset sizes for your indoor selected models.
** *When using the PLA-A24BA6, PEAD-A24AA5, PEADA30AA5, PEAD-A36AA5, MSZ-GL24NA two port adapters
will be needed
1-MAC-A456JP-E (1/2" x 5/8") or 1-PAC-SG76RJ-E (3/8" x
5/8") and 1 - PAC-493Pl (1/4" x 3/8").
1/2" gas x 1/4" liquid
1/2" gas x 1/4" liquid
5/8" gas x 3/8" liquid
5/8" gas x 3/8" liquid
5/8" gas x 3/8" liquid
INDOOR INTAKE AIR TEMPERATURE
Notes for application:
** *Connect 15K + indoor units to the larger 1/2" port on the
PAC-MKA50BC branch box or outdoor unit.
3/8" gas x 1/4" liquid
3/8" gas x 1/4" liquid
1/2" gas x 1/4" liquid
M-SERIES OPERATING CONDITIONS
PAC-MKA50BC [5-Port]
A; B; C; D
3/8" gas x 1/4" liquid
3/8" gas x 1/4" liquid
3/8" gas x 1/4" liquid
1/2" gas x 1/4" liquid
1/2" gas x 1/4" liquid
5/8" gas x 3/8" liquid
3/8" gas x 1/4" liquid
3/8" gas x 1/4" liquid
3/8" gas x 1/4" liquid
3/8" gas x 1/4" liquid
1/2" gas x 1/4" liquid
SLZ-KA09NA
SLZ-KA12NA
SLZ-KA15NA
SEZ/PEAD Horizontal-ducted
SEZ-KD09NA4
SEZ-KD12NA4
SEZ-KD15NA4
SEZ-KD18NA4
PEAD-A24AA5
PEAD-A30AA5
PEAD-A36AA5
MXZ-8C48NA
MXZ-4C36NAHZ
MXZ-5C42NAHZ
MXZ-8C48NAHZ
LINE SET SIZE
MUZ-FH
MXZ-2B20NA-1
Minimum
MXZ-3C24/3C30/4C36/5C42NA
MXZ-2C20/3C24/3C30NAHZ
MXZ-8C48NA
MXZ-4C36/54C42/8C48NAHZ
67° F D.B., 57° F W.B.
M-SERIES OPERATING CONDITIONS (CONT.)
REFRIGERANT LINE LENGTH
Indoor Unit
Outdoor Unit
Length
in Feet
Vertical
Separation
in Feet
MSZ-FH09NA
MUZ-FH09NA
65
40
MSZ-FH12NA
MUZ-FH12NA
65
40
MSZ-FH15NA
MUZ-FH15NA
100
50
MSZ-FH18NA
MUZ-FH18NA
100
50
MSY-GE09NA-9
MUY-GE09NA2
65
40
MXZ-8C48NA
MSY-GE12NA-9
MUY-GE12NA2
65
40
MXZ-2C20/3C24/3C30NAHZ
MSY-GE15NA-9
MUY-GE15NA2
65
40
MXZ-4C36/54C42/8C48NAHZ
MSY-GE18NA-9
MUY-GE18NA-1
100
50
MSY-GE24NA
MUY-GE24NA
100
50
MSZ-GE09NA-9
MUZ-GE09NA2
65
40
MSZ-GE12NA-9
MUZ-GE12NA2
65
40
MSZ-GE15NA-9
MUZ-GE15NA2
65
40
MXZ-8C48NA
MSZ-GE18NA-9
MUZ-GE18NA-1
100
50
MXZ-2C20/3C24/3C30NAHZ
MSZ-GE24NA
MUZ-GE24NA
100
50
MXZ-4C36/54C42/8C48NAHZ
MSY-D30NA-8
MUY-D30NA-1
100
50
MSY-D36NA-8
MUY-D36NA-1
100
50
MSZ-D30NA-8
MUZ-D30NA-1
100
50
MSZ-D36NA-8
MUZ-D36NA-1
100
50
MSZ-FE09NA-8
MUZ-FE09NA-1
65
40
MSZ-FE12NA-8
MUZ-FE12NA-1
65
40
MSZ-FE18NA
MUZ-FE18NA
100
50
SEZ-KD09NA4
SUZ-KA09NA
65
40
SEZ-KD12NA4
SUZ-KA12NA
65
40
MXZ-2C20/3C24/3C30NAHZ
SEZ-KD15NA4
SUZ-KA15NA
65
40
MXZ-4C36/54C42/8C48NAHZ
SEZ-KD18NA4
SUZ-KA18NA
100
50
MUZ/Y-GL/D
SLZ-KA09NA
SUZ-KA09NA
65
40
SLZ-KA12NA
SUZ-KA12NA
65
40
SLZ-KA15NA
SUZ-KA15NA
65
40
MSZ-GE/FH; MFZ; SEZ; SLZ
MXZ-2B20NA-1
164
49*/33
MXZ-3C24NA
230
49
MXZ-3C30NA
230
49
MXZ-4C36NA
230
49
MXZ-5C42NA
262
49
MXZ-8C48NA
492
131*/164
MXZ-2C20NAHZ
164
49
MXZ-3C24NAHZ
230
49
MXZ-3C30NAHZ
230
49
MXZ-4C36NAHZ
492
131*/164
MXZ-5C42NAHZ
492
131*/164
MXZ-8C48NAHZ
492
131*/164
INDOOR INTAKE AIR TEMPERATURE
MODELS
CONDITIONS
MUZ/Y-GL/D
MUZ-FH
SUZ
Maximum
Heating
MXZ-2B20NA-1
MXZ-3C24/3C30/4C36/5C42NA
80° F D.B., 67° F W.B.
MUZ-GL/D
MUZ-FH
SUZ
Minimum
MXZ-2B20NA-1
MXZ-3C24/3C30/4C36/5C42NA
70° F D.B., 60° F W.B.
OUTDOOR INTAKE AIR TEMPERATURE
MODELS
CONDITIONS
MUZ/Y-GL/D
MUZ-FH
SUZ
Maximum
MXZ-2B20NA-1
MXZ-3C24/3C30/4C36/5C42NA
115° F D.B.
MXZ-8C48NA
Cooling
FLARE/FLARE
MUZ-FH
23° F D.B.
MXZ-2B20NA-1
Minimum
MXZ-3C24/3C30/4C36/5C42NA
MXZ-2C20/3C24/3C30NAHZ
14° F D.B.
MXZ-8C48NA
MXZ-4C36/54C42/8C48NAHZ
MUZ/Y-GL/D
MUZ-FH
SUZ
Maximum
MXZ-2B20NA-1
75° F D.B., 65° F W.B
MXZ-3C24/3C30/4C36/5C42NA
MXZ-8C48NA
MXZ-2C20/3C24/3C30NAHZ
MXZ-4C36/54C42/8C48NAHZ
Heating
Minimum
70° F D.B., 59° F W.B
"MUZ-GL/D
-13° F D.B., -14° F W.B.
MXZ-2C20/3C24/3C30NAHZ
-12° F D.B., -13° F W.B.
MXZ-4C36/54C42/8C48NAHZ
-13° F W.B.
MXZ-8C48NA
-4° F W.B.
MUZ/Y-GL/D
-4° F D.B., -5° F W.B.
MSZ-GE/FH
MFZ
MVZ
SEZ
SLZ
*49' and 131' applies to installations where the outdoor unit is installed below the
indoor unit.
SUZ
MUZ/Y-D
MXZ-2B20NA-1
14° F D.B., 13° F W.B.
6° F D.B., 5° F W.B.
MXZ-3C24/3C30/4C36/5C42NA
MITSUBISHI ELECTRIC / M-SERIES / SPECIFICATIONS / 53
M-SERIES COOLING CAPACITY CORRECTION FACTOR
Model
M-SERIES AIR OUTLET COVERAGE RANGE*
Refrigerant Piping Length (One Way)
25 Ft (Std)
40 Ft
65 Ft
Capacity x 1.0
Capacity
x 0.954
Capacity
x 0.878
100 Ft
MUZ-GE09NA2
MUZ-GE12NA2
MUZ-GE15NA2
-
MUZ-GE18NA-1
MUZ-GE24NA
MUZ-D30NA-1
Capacity x 1.0
Capacity
x 0.954
Capacity
x 0.878
Capacity x 1.0
Capacity
x 0.95
Capacity
x 0.878
Capacity x 1.0
Capacity
x 0.954
Capacity
x 0.878
MUY-GE12NA2
Capacity
x 0.771
Capacity
x 0.713
-
MUY-GE15NA2
MUY-D30NA-1
Capacity x 1.0
Capacity x 1.0
MUY-D36NA-1
MUZ-FE09NA-1
Capacity x 1.0
MUZ-FE12NA-1
MUZ-FE18NA
MUZ-FH09NA
MUZ-FH12NA
MUZ-FH15NA
MUZ-FH18NA
Function
Airflow
(CFM)
Coverage
(FT)
MSZ/Y-GE06NA-9
MSZ/Y-GE09NA-9
MSZ/Y-GE12NA-9
HEAT
DRY
406
29.5
COOL
WET
286
21.0
HEAT
DRY
463
33.5
COOL
WET
385
28.0
HEAT
DRY
512
36.9
COOL
WET
385
28.0
HEAT
DRY
738
36.9
COOL
WET
661
33.2
HEAT
DRY
848
45.0
COOL
WET
763
40.7
HEAT
DRY
381
27.7
COOL
WET
307
22.4
HEAT
DRY
420
30.4
COOL
WET
350
25.4
HEAT
DRY
738
36.9
COOL
WET
661
33.2
HEAT
DRY
437
29.8
COOL
WET
328
22.5
HEAT
DRY
454
31.0
COOL
WET
342
23.5
HEAT
DRY
497
33.8
COOL
WET
354
24.1
HEAT
DRY
514
23.0
COOL
WET
376
16.7
HEAT
DRY
332
15.4
COOL
WET
303
14.2
HEAT
DRY
335
15.6
COOL
WET
309
14.5
HEAT
DRY
434
20.0
COOL
WET
379
17.5
HEAT
DRY
350
12.1
COOL
WET
320
1.1
HEAT
DRY
390
13.5
COOL
WET
350
12.1
HEAT
DRY
390
13.5
COOL
WET
350
12.1
MSZ/Y-GE18NA-9
MSZ/Y-GE24NA
MSZ/Y-D30NA-8
MSZ/Y-D36NA-8
MSZ-FE09NA-8
MUY-GE18NA-1
MUY-GE24NA
Mode
MSZ/Y-GE15NA-9
MUZ-D36NA-1
MUY-GE09NA2
Model
Capacity x 1.0
Capacity x 1.0
Capacity x 1.0
Capacity
x 0.954
Capacity
x 0.878
Capacity
x 0.771
Capacity
x 0.95
Capacity
x 0.878
Capacity
x 0.713
Capacity
x 0.945
Capacity
x 0.878
-
Capacity
x 0.945
Capacity
x 0.878
Capacity
x 0.771
Capacity
x 0.945
Capacity
x 0.878
-
Capacity
x 0.945
Capacity
x 0.878
Capacity
x 0.771
MSZ-FE12NA-8
MSZ-FE18NA
MSZ-FH09NA
MSZ-FH12NA
MSZ-FH15NA
MSZ-FH18NA
SUZ-KA09NA
SUZ-KA12NA
SUZ-KA15NA
Capacity x 1.0
Capacity
x 0.954
Capacity
x 0.878
-
SUZ-KA18NA
MFZ-KA09NA
MFZ-KA12NA
MFZ-KA18NA
M-SERIES SIZING
It is very important that all contractors follow proper procedure and size
units based on a Manual J calculation. A load calculation takes into
account all the factors that cause the building to lose heat in the winter
and gain heat in the summer. Some of the factors taken into consideration
are exposed walls, insulation, windows, doors, and even the direction
the building faces.
INVERTER-driven technology has changed the way heat pumps are used.
Because the inverter can vary the capacity of the system, we can now
size units based on the largest load, which in many cases may be the
heat load. When single speed compressors are sized on heat load and
changed over to cooling, the units can be grossly over-sized. The result
is very little dehumidification and comfort problems.
Using charts like the ones below from the technical service manual, you
can check the equipment capacity at the design temperatures for heating
and cooling. If these values fall within both the heating and cooling
capacity ranges of the system, you can select that system
with confidence.
54 / MITSUBISHI ELECTRIC / M-SERIES / SPECIFICATIONS
SLZ-KA09NA
SLZ-KA12NA
SLZ-KA15NA
*Air coverage represents the distance with one ft/sec air speed when blowing out
horizontally from the unit operating at the High fan speed. This is only a general
guideline; actual coverage depends on size and layout of the room.
MULTI-ZONE EFFICIENCY RATINGS
Model
MXZ-2B20NA-1
MXZ-3C24NA
MXZ-3C30NA
MXZ-4C36NA
MXZ-5C42NA
MXZ-8C48NA
MXZ-2C20NAHZ
MXZ-3C24NAHZ
MXZ-3C30NAHZ
MXZ-4C36NAHZ
MXZ-5C42NAHZ
MXZ-8C48NAHZ
Configuration
SEER
HSPF
Non-Ducted
18.00
8.90
Mixed
16.75
8.70
Ducted
15.50
8.50
Non-Ducted
20.00
9.80
Mixed
18.00
9.50
Ducted
16.00
9.20
Non-Ducted
19.00
10.60
Mixed
17.60
10.10
Ducted
16.20
9.60
Non-Ducted
19.20
11.00
Mixed
16.00
10.40
Ducted
17.45
9.80
Non-Ducted
19.70
10.30
Mixed
17.45
9.70
Ducted
15.20
9.10
Non-Ducted
18.90
11.40
Mixed
16.80
10.75
Ducted
14.70
10.10
Non-Ducted
17.00
9.80
Mixed
16.00
9.65
Ducted
15.00
9.50
Non-Ducted
19.00
10.00
Mixed
17.25
9.50
Ducted
15.50
9.00
Non-Ducted
18.00
11.00
Mixed
17.00
10.70
Ducted
16.00
9.80
Non-Ducted
19.10
11.30
Mixed
17.45
10.70
Ducted
15.80
10.70
Non-Ducted
19.00
11.00
Mixed
17.00
10.55
Ducted
15.00
10.10
Non-Ducted
18.90
11.00
Mixed
16.80
10.50
Ducted
14.70
10.00
M-Series systems are not
recommended for critical room
and low ambient cooling applications.
Use commercial grade P-Series with
full cooling capacity down to 0o F with
wind baffle.
MITSUBISHI ELECTRIC / M-SERIES / SPECIFICATIONS / 55
MSZ AND MUZ-FH COOLING CAPACITY
COOLING CAPACITY
Indoor Air
Model
IWB (˚ F)
MUZ-FH06NA
MUZ-FH09NA-1
MUZ-FH12NA-1
MUZ-FH15NA
MUZ-FH18NA2
NOTE:
Outdoor Intake air D.B. Temperature (˚ F)
75
85
95
105
115
TC
SHC
TPC
TC
SHC
TPC
TC
SHC
TPC
TC
SHC
TPC
TC
SHC
TPC
71
7.4
6.1
0.28
6.9
5.7
0.31
6.5
5.3
0.33
6
5
0.35
5.5
4.6
0.36
67
7
6.7
0.26
6.5
6.2
0.29
6
5.8
0.32
5.6
5.4
0.33
5.1
4.9
0.35
63
6.5
7.2
0.25
6.1
6.6
0.28
5.6
6.2
0.3
5.1
5.6
0.32
4.7
5.1
0.33
71
11
8.7
0.5
10.3
8.1
0.55
9.7
7.6
0.59
9
7.1
0.62
8.3
6.5
0.64
67
10.4
9.6
0.47
9.7
8.9
0.52
9
8.3
0.56
8.4
7.7
0.59
7.7
7.1
0.62
63
9.8
10.3
0.45
9.1
9.6
0.5
8.5
8.9
0.53
7.7
8.1
0.57
7
7.4
0.59
71
14.7
10.2
0.77
13.7
9.6
0.85
12.9
9
0.91
12
8.4
0.96
11
7.7
1
67
13.9
11.6
0.73
13
10.8
0.8
12
10
0.87
11.2
9.3
0.92
10.3
8.5
0.97
63
13.1
12.6
0.7
12.1
11.7
0.77
11.3
10.9
0.83
10.3
9.9
0.89
9.4
9
0.92
71
18.4
10.4
1.07
17.2
9.7
1.17
16.1
9.1
1.26
15
8.5
1.33
13.8
7.8
1.38
67
17.4
12.2
1.01
16.2
11.3
1.11
15
10.5
1.2
14
9.8
1.27
12.8
9
1.33
63
16.4
13.6
0.96
15.2
12.6
1.06
14.1
11.8
1.15
12.8
10.7
1.22
11.7
9.8
1.27
71
21.1
11.3
1.22
19.7
10.6
1.34
18.5
9.9
1.44
17.2
9.2
1.52
15.8
8.5
1.58
67
20
13.4
1.16
18.6
12.4
1.27
17.2
11.5
1.38
16
10.7
1.46
14.7
9.9
1.53
63
18.7
15.1
1.1
17.4
14
1.22
16.2
13
1.31
14.7
11.8
1.4
13.4
10.8
1.46
1. IWB: Intake air wet-bulb temperature
SHC: Sensible Heat Capacity (x103 Btu/h)
TC: Total Capacity (x103 Btu/h)
TPC: Total Power Consumption (kW)
2. SHC is based on 80˚ F of indoor Intake air DB temperature.
56 / MITSUBISHI ELECTRIC / M-SERIES / SPECIFICATIONS
MSZ AND MUZ-FH HEATING CAPACITY
HEATING CAPACITY
Indoor Air
Model
IDB (˚ F)
MUZ-FH06NA
MUZ-FH09NA-1
MUZ-FH12NA-1
MUZ-FH15NA
MUZ-FH18NA2
NOTE:
Outdoor Intake air D.B. Temperature (˚ F)
5
15
25
35
43
45
55
TC
TPC
TC
TPC
TC
TPC
TC
TPC
TC
TPC
TC
TPC
TC
TPC
75
7.4
0.32
5
0.41
6.3
0.48
7.5
0.53
8.5
0.56
8.7
0.57
9.9
0.59
70
7
0.31
5.4
0.39
6.5
0.47
7.7
0.52
8.7
0.55
9
0.56
10.1
0.58
65
6.5
0.29
5.5
0.38
6.8
0.45
8
0.5
9
0.53
9.2
0.54
10.4
0.57
75
11
0.42
6.3
0.53
7.9
0.62
9.4
0.69
10.6
0.73
11
0.74
12.4
0.77
70
10.4
0.4
6.7
0.51
8.2
0.61
9.6
0.67
10.9
0.71
11.2
0.72
12.7
0.75
65
9.8
0.38
6.9
0.49
8.6
0.59
10
0.66
11.2
0.69
11.6
0.7
13
0.74
75
14.7
0.56
7.9
0.71
9.9
0.83
11.8
0.93
13.3
0.97
13.7
0.99
15.5
1.03
70
13.9
0.54
8.4
0.68
10.2
0.81
12
0.9
13.6
0.95
14
0.97
15.8
1.01
65
13.1
0.51
8.6
0.66
10.7
0.78
12.4
0.88
14
0.93
14.4
0.94
16.2
0.99
75
18.4
0.77
10.4
0.97
13.1
1.14
15.6
1.27
17.6
1.33
18.1
1.35
20.5
1.4
70
17.4
0.73
11.1
0.94
13.5
1.11
15.9
1.24
18
1.3
18.5
1.33
21
1.38
65
16.4
0.7
11.3
0.9
14.1
1.07
16.5
1.2
18.5
1.27
19.1
1.29
21.4
1.35
75
21.1
1.01
11.8
1.28
14.7
1.51
17.6
1.68
19.8
1.76
20.4
1.79
23.1
1.86
70
20
0.97
12.5
1.24
15.2
1.47
18
1.63
20.3
1.72
20.9
1.75
23.6
1.82
65
18.7
0.93
12.8
1.19
15.9
1.42
18.6
1.59
20.9
1.68
21.5
1.7
24.2
1.79
1. IDB: Intake air dry-bulb temperature
TC: Total Capacity (x103 Btu/h) TPC : Total Power Consumption (kW)
2. Above data is for heating operation without any frost.
MITSUBISHI ELECTRIC / M-SERIES / SPECIFICATIONS / 57
NOTES
58 / MITSUBISHI ELECTRIC / M-SERIES / SPECIFICATIONS
Variable Refrigerant Flow
CATALOG
VARIABLE REFRIGERANT FLOW ZONING SYSTEMS
P-SERIES
INVERTER-driven
P-SERIES FULL LINE CATALOG
COMMERCIAL-GRADE APPLICATIONS
Smart, Efficient INVERTER-driven
Ductless and Ducted Comfort Systems
01.2016_REVISED
I ©2016 MITSUBISHI ELECTRIC US, INC.
MITSUBISHI ELECTRIC Cooling & Heating / CITY MULTI / FC1
For more information on our
CITY MULTI VRF product line visit our website at
mitsubishipro.com
P-SERIES CATALOG
I
02.2016 REVISED
I
©2016 MITSUBISHI ELECTRIC US, INC.
www.mitsubishipro.com
For more information on our
INVERTER- driven product line visit our website at mitsubishipro.com
MITSUBISHI ELECTRIC / M-SERIES / SPECIFICATIONS / 59
©2016 Mitsubishi Electric US, Inc. All rights reserved.
Mitsubishi Electric, Lossnay, and the three-diamond logo are trademarks of Mitsubishi Electric
Corporation. CITY MULTI, kumo cloud and H2i are trademarks of Mitsubishi Electric US, Inc. All other
product names mentioned herein are trademarks or registered trademarks of their respective owners.
MAKE COMFORT
ENERGY STAR and the ENERGY STAR mark are registered trademarks owned by the United States
Environmental Protection Agency.
Use of the AHRI Certified™ mark indicates a manufacturer’s participation in the certification program.
For verification of certification for individual products, go to www.ahridirectory.org.
Mitsubishi Electric Cooling & Heating
1340 Satellite Boulevard, Suwanee, GA 30024
Phone: 800-433-4822
Specifications shown in this brochure are subject to change without notice. See complete warranty
for terms, conditions and limitations. A copy is available from Mitsubishi Electric.
For more information visit www.mitsubishipro.com
VERSION MSCG 04.2016 I REVISED I SKU: ME-1022 I ©2016 MITSUBISHI ELECTRIC US, INC.