Friedrich | M18CFKIT | Product Brochure | Friedrich M18CFKIT Product Brochure

Ductless SPLIT SYSTEMS
2009
cool only | HEAT PUMPS
Friedrich Ductless Split Systems
The ultimate room air conditioner
Easy to install
Easy to install. Exceptionally quiet. Totally flexible.
Friedrich ductless split systems have the
advantages of a ducted installation without
the high material and labor costs. Absolutely
no ductwork is required, so most systems
can be installed and running in a few hours.
Like a central system, without the ductwork.
SEER ratings up to 20.0
All Friedrich ductless models exceed the
federal 13.0 SEER requirements. And, a full
one-third of our models have super high
ratings ranging from 16.5 to 20.0 SEER.
electric wiring
refrigerant lines
Indoor unit
converts warm indoor
air to cold indoor air,
conditioning and
dehumidifying the room.
Unit is mounted high on
the wall.
Extremely quiet
Ductless systems keep the operating noise
of the condensing unit outdoors, while
the blower fan of the indoor unit remains
whisper quiet.
REFRIGERANT LINES AND
ELECTRICAL pass through
a 3” wall opening and run
along the exterior of the
building to the condensing
unit. Electrical hard-wiring
is required.
Outdoor condenser
transfers heat to the outdoors.
Compact unit can be placed
at ground level, hung on an
outside wall or placed on the
roof of a building
Zero duct loss
The DOE reports that ducted systems lose
an average of 25-40% in performance due to
leaks, cracks or disconnections in ductwork.
No ductwork means zero duct loss.
hard-wired
No dirty air ducts
Ductless splits are an innovative and efficient alternative to
window and thru-the-wall units. They have the benefits of a
central system, without the difficulty and expense of installing
ductwork. These are only a few of the benefits of ductless...
Ever wonder how much dirt and mold is
in your ductwork? Now there’s no need to
clean dirty air ducts that can harbor dust,
germs and allergens that are eventually
blown into your home or office.
• Unobstructed window views.
• No need to uninstall and store unit during the winter.
• Independently-controlled zone cooling means up to four separate
indoor units working from a single outdoor unit.
• Save money by turning off units in unoccupied rooms. • Set room temperatures based on individual preferences
• Zero duct loss; no loss of performance from leaky ducts
• No dust, germs and allergens spread via ductwork
INVERTER
TECHNOLOGY
R-410A
All models use
environmentally
friendly R-410A
refrigerant.
The indoor unit and outdoor unit are
connected by refrigerant and power lines,
through a small three-inch hole in the wall.
Zone 1
Zone 2
Zone 3
Zone 4
Zone cooling flexibility
Independently condition up to 4 separate rooms using only a single outdoor unit.
Reduce energy use and save money by cooling and heating only the rooms that are
in use.
Variable capacity advantages
Inverter Technology allows each system to adjust capacity and cooling output
to provide only the amount of cooling needed at a given time. For example, an
18,000 BTU/h system will operate even more efficiently as a 15,500 if that is all
that’s needed.
Advanced inverter technology
As illustrated in the chart below, Inverter Technology lets you reach the desired
temperature faster, maintain it more accurately, and reduce energy costs. It
eliminates constant compressor start-ups/shut-downs that traditional technology
requires to maintain the set temperature.
Inverter Technology
Inverter Energy Usage
Precise comfort from
one system in up to four
different rooms.
That’s the beauty– and
efficiency of a Friedrich
Multi-zone system.
Standard Technology
Standard Energy Usage
Initial
startup
2nd
startup
3rd
startup
setpoint
Inverter reaches
setpoint faster, then
adjusts capacity as
required to maintain
accurate temp
1st
shutdown
Residential applications
2nd
shutdown
Commercial applications
• Room additions/renovations
• Computer rooms/server rooms
• Homes without ductwork
• Restaurant kitchen and prep areas
• Bedrooms and family rooms
• Offices in warehouse spaces
• Garage workshops
• Storage facilities
• Sunrooms
• Guest quarters
• Buildings where security concerns prevent
the use of window units
• Wine cellars
• Internal areas without exterior wall access
Learn more about ductless
visit www.friedrich.com
to see our new online video on the
advantages of Friedrich ductless
split systems
Wall-mounted single zone
Wall-mounted multi-zone heat pump
One wall-mounted indoor unit
connected to one outdoor unit.
Two, three or four wall-mounted indoor
units connected to one outdoor unit.
Features
Features
• Auto swing louvers (up/down)
• Auto swing louvers (up/down)
• Continuous ‘Air Sweep’
• Continuous ‘Air Sweep’
• Auto-restart after power interruptions
• Auto-restart after power interruptions
• Auto-shut flaps close when unit is off
for a sleeker appearance
• Auto-shut flaps close when unit is off
• Washable, reusable air filters
• Removable front grille
• Removable front grille
• Auto-changeover
• Auto-changeover (heat pump models)
• Low-ambient operation
• Washable, reusable air filters
Commercial applications
including restaurant dining
areas and kitchens
Fully featured and fully
programmable for total
convenience
Auto-shut flaps close
when unit is off for a
sleeker appearance.
The continuous ‘Air
Sweep’ auto louvers
gently distribute cool or
warm air throughout
the room.
Auto-changeover on
heat pump models
automatically switches
the unit from cool to
heat; or from heat to
cool to maintain desired
temperature.
LCD wireless remote
• LCD remote for each indoor unit
• 24-hour timer and sleep timer
• Auto/cool/dry/fan/heat* modes
• Four fan speeds heating* or cooling:
high/medium/low/quiet, plus auto-fan
• Secured remote control holder
• Four different transmitter codes to prevent
unintentional interference with nearby units
* Heat pump models only
Pictured: Single zone model MW24CF indoor unit. Multi-zone system M36QYF.
Appearance varies by model.
multi-zone cool/heat pump
cool only
model
btu/h
seer
MO9CF
9700
14.3
M12CF
12300
13.5
M18CF
18000
19.0
M24CF
24200
18.0
M30CF
30700
15.0
M36CF
33100
15.0
R-410A
All models use
environmentally
friendly R-410A
refrigerant.
M09YG
M12YG
M18YF
= cooling capacity
= heating capacity
M24YF
btu/h
8500
10000
11500
14000
18000
21600
24200
27600
zone 1
zone 2
9500
11000
9500
11000
12000
14000
9200
11200
9300
11000
9400
10700
9100
9800
11700
12700
8800
9500
btu/h
9500
—
11000
12000
—
14000
12000
—
14000
9200
9200
11200 11200
9300 11800
11000 14000
11800 11800
13600 13600
9100 17000
9800 18400
11700 11700
12700 12700
8800
8800
9500
9500
model
M18DYF
M21DYF
M24DYF
M27TYF
cool/ heat pump
model
INVERTER
TECHNOLOGY
seer
M30TYF
20.0
M33TYF
20.0
M36TYF1
19.0
M36TYF2
18.0
M36QYF
zone 3
zone 4
—
—
—
—
—
—
—
—
8800
9500
total btu
19000
22000
21500
25000
24000
28000
27600
33600
30400
36000
33000
37900
35200
38000
35100
38100
35200
38000
seer
16.5
16.5
16.5
15.0
15.0
15.0
15.0
15.0
15.0
Floor/ceiling universal heat pump
Ceiling cassette heat pump
Universal system may be located low
against the wall or on the ceiling.
• Auto-swing louvers (up/down)
Features
• Continuous ‘Air Sweep’
Features
• Auto-restart after power
interruptions
• Auto swing louvers (up/down, left/right)
• Continuous ‘Air Sweep’
• Auto-changeover
• Auto-restart after power interruptions
• Washable, reusable air filters
• Auto-shut flaps close when unit is off
for a sleeker appearance
• Low-ambient operation
• Fresh air intake
• Auto-changeover
• Two branch ducts for
adjoining rooms (requires additional fan)
• Washable, reusable air filters
• Fresh air capability
• Condensate pump: 31" lift
9 1/4"
• Auto-shut flaps close when unit is off
LCD wireless remote
• 24-hour timer and sleep timer
LCD wired remote
• Auto/cool/dry/fan/heat modes
low profile– 9 ¼" above ceiling
• Three fan speeds heating or cooling:
high/medium/low, plus auto-fan
• Seven-day programmable on/off timer
controls up to 16 units– individually or by
zones
• Four different transmitter codes
• Auto/cool/dry/fan/heat modes
cool/ heat pump
• Secured remote control holder
• Self-diagnostics
C24YF
• Self-diagnostics
• Three fan speeds heating or cooling:
high/medium/low, plus auto-fan
22,200 BTU/h 15.0 SEER
24,200 BTU/h
Ceiling suspended heat pump
Features
• Auto swing louvers (up/down, left/right)
• Continuous ‘Air Sweep’
mounts on the ceiling
or low against the wall
• Auto-restart after power interruptions
• Auto-shut flaps
• Washable, reusable
air filters
• Fresh air capability
• Auto-changeover
• Low-ambient operation
• Optional DP-36 condensate pump
LCD wireless remote
cool/ heat pump
S24YF
22,200 BTU/h 15.0 SEER
24,200 BTU/h
• 24-hour timer and sleep timer
• Four different transmitter codes
• Auto/cool/dry/fan/heat modes
• Secured remote control holder
• Three fan speeds heating or
cooling: high/medium/low,
plus auto-fan
• Self-diagnostics
cool/ heat pump
S36YF
INVERTER
TECHNOLOGY
INVERTER
TECHNOLOGY
34,100 BTU/h 14.0 SEER
38,200 BTU/h
Wall mounted cooling
Inverter model
PERFORMANCE RATINGS
SYSTEM MODEL NO.
INDOOR MODEL
OUTDOOR MODEL
Capacity Cooling
BTU/h
Capacity Cooling Min - Max
BTU/h
Sensible Heat Ratio
SEER
EER
Moisture Removal
Pts/h
Airflow (Quiet, Low, Med, High) CFM
Sound Rating - Indoor
dB-A
Sound Rating - Outdoor
dB-A
Operating Range
°F
M09CF
MW09C1F
MR09C1F
9700
9700
0.67
14.3
11.8
2.1
185/220/260/295
26/31/36/40
43
0 - 115
M12CF
MW12C1F
MR12C1F
12300
12300
0.65
13.5
11.6
3.2
215/250/305/355
28/35/40/45
45
0 - 115
M18CF
MW18C3F
MR18C3F
18000
5500-19000
0.63
19.0
10.4
5.9
240/290/355/415
25/32/38/44
50
0 - 115
M24CF
MW24C3F
MR24C3F
24200
5200-26000
0.76
18.0
10.5
5.3
380/450/560/650
32/36/41/47
52
0 - 115
M30CF
MW30C3F
MR30C3F
30700
9900-34200
0.67
15.0
8.9
9.7
380/450/560/650
32/36/41/47
53
0 - 115
M36CF
MW36C3F
MR36C3F
33100
9900-34100
0.67
15.0
8.2
10.1
365/440/530/700
32/36/41/49
54
0 -115
A
W
A
115-60-1
12
820
15
115-60-1
15
1060
20
230/208-60-1
16
1730
20
230/208-60-1
21
2310
30
230/208-60-1
22
3460
30
230/208-60-1
22
4040
30
in
in
ft
ft
ft
R410A
Rotary
Flare
1/4
3/8
25
49
26
R410A
Rotary
Flare
1/4
3/8
25
49
26
R410A
Inverter
Flare
1/4
1/2
49
66
49
R410A
Inverter
Flare
1/4
5/8
49
98
66
R410A
Inverter
Flare
3/8
5/8
66
164
98
R410A
Inverter
Flare
3/8
5/8
66
164
98
39 1/4 x 12 5/8 x 9
39 1/4 x 12 5/8 x 9
31
40
31
40
35 3/8 x 32 5/8 x 13
35 3/8 x 32 5/8 x 13
137
155
137
155
ELECTRICAL DATA
Power Source
Min. Ampacity
Cooling Watts
Max. TD Fuse/Breaker
REFRIGERATION SYSTEM
Refrigerant
Compressor Type
Connections
Liquid Line O.D.
Suction Line O.D.
Factory Precharge
Max. Line Length
Max. Height Difference
DIMENSIONS & WEIGHT
INDOOR
UNIT
OUTDOOR
UNIT
WxHxD
Net Weight
Shipping Weight
WxHxD
Net Weight
Shipping Weight
39 1/4 x 12 5/8 x 9
in 31 1/8 x 10 7/8 x 8 1/2 31 1/8 x 10 7/8 x 8 1/2 31 1/8 x 10 7/8 x 8 1/2
lbs
21
21
21
31
lbs
26
26
26
40
in 31 1/8 x 21 1/4 x 11 3/8 31 1/8 x 21 1/4 x 11 3/8 31 1/8 x 22 3/4 x 12 3/8 31 1/8 x 22 3/4 x 12 3/8
lbs
68
77
88
97
lbs
77
86
98
106
Wall mounted heat pumps
PERFORMANCE RATINGS
SYSTEM MODEL NO.
INDOOR MODEL
OUTDOOR MODEL
Capacity Cooling
Cooling Capacity Min - Max
Sensible Heat Ratio
Capacity Heating @ 47°F
Capacity Heating Min - Max
Capacity Heating @ 17°F
HSPF
SEER
EER
Moisture Removal
Airflow (Quiet, Low, Med, High)
Sound Rating - Indoor
Sound Rating - Outdoor
Operating Range COOL (HEAT)
M09YG
MW09Y3G
MR09Y3G
8500
1700-10900
0.71
10000
1700-15000
8500
10.0
20.0
12.3
2.8
178/260/361/444
22/33/38/43
46
0 - 115 (17-75)
M12YG
MW12Y3G
MR12Y3G
11500
3100-13300
0.71
14000
3100-19100
11000
10.0
20.0
12.1
3.8
178/260/361/444
22/33/38/43
49
0 - 115 (17-75)
M18YF
MW18Y3F
MR18Y3F
18000
5500-19000
0.63
21600
4600-29000
13700
10.0
19.0
10.4
5.9
240/290/355/415
25/32/38/44
50
0 - 115 (5-75)
M24YF
MW24Y3F
MR24Y3F
24200
5200-26000
0.76
27600
4100-36200
17800
10.0
18.0
10.5
5.3
380/450/560/650
32/36/41/47
52
0 - 115 (5-75)
A
W
A
230/208-60-1
15
690
15
230/208-60-1
15
930
15
230/208-60-1
16
1730
20
230/208-60-1
21
2310
30
in
in
ft
ft
ft
R410A
Inverter
Flare
1/4
3/8
25
66
49
R410A
Inverter
Flare
1/4
3/8
25
66
49
R410A
Inverter
Flare
1/4
1/2
49
66
49
R410A
Inverter
Flare
1/4
5/8
49
98
66
BTU/h
BTU/h
BTU/h
BTU/h
BTU/h
Pts/h
CFM
dB-A
dB-A
°F
ELECTRICAL DATA
Power Source
Min. Ampacity
Cooling Watts
Max. TD Fuse/Breaker
REFRIGERATION SYSTEM
Refrigerant
Compressor Type
Connections
Liquid Line O.D.
Suction Line O.D.
Factory Precharge
Max. Line Length
Max. Height Difference
DIMENSIONS & WEIGHT
INDOOR
UNIT
OUTDOOR
UNIT
WxHxD
Net Weight
Shipping Weight
WxHxD
Net Weight
Shipping Weight
in
lbs
lbs
in
lbs
lbs
31 1/8 x 10 1/4 x 7 5/8
31 1/8 x 10 1/4 x 7 5/8
31 1/8 x 10 7/8 x 8 1/2
39 1/4 x 12 5/8 x 9
16.5
21
16.5
21
21
26
31
40
26 x 21 1/4 x 11 3/8
26 x 21 1/4 x 11 3/8
31 1/8 x 22 3/4 x 12 3/8
31 1/8 x 22 3/4 x 12 3/8
55
63
71
78
88
98
97
106
Dual-zone heat pumps
inverter model
PERFORMANCE RATINGS
SYSTEM MODEL NO.
M18DYF
M21DYF
INDOOR MODEL
2 x MW09Y3FM
MW09Y3FM
MW12Y3FM
OUTDOOR MODEL
MR24DY3F
MR24DY3F
Capacity Cooling
BTU/h
9500 ea.
9500 ea.
12000
Capacity Cooling Min - Max
BTU/h
5100-11300
5100-11300
5100-13600
Sensible Heat Ratio
0.77
0.77
0.77
Capacity Heating @ 47°F
BTU/h
11000 ea.
11000 ea.
14000
Capacity Heating Min - Max
BTU/h
5100-13000 ea.
5100-13000 ea.
5100-15400 ea.
Capacity Heating @ 17°F
BTU/h
9500 ea.
9500 ea.
11000
HSPF
9.0
9.0
SEER
16.5
16.5
EER
12.2
11.2
Moisture Removal
Pts/h
2.9 ea.
2.9 ea
3.7 ea.
Airflow (Quiet, Low, Med, High)
CFM
185/220/260/295
185/220/260/295 215/250/305/355
Sound Rating - Indoor
dB-A
27/29/33/37
27/29/33/37
30/34/39/42
Sound Rating - Outdoor
dB-A
52
52
Operating Range COOL (HEAT)
°F
0 - 115 (14-75)
0 - 115 (14-75)
ELECTRICAL DATA (all indoor units receive power from outdoor unit; values listed are total)
Power Source
230/208-60-1
230/208-60-1
Min. Ampacity
A
15
15
Cooling Watts
W
1600
1900
Max. TD Fuse/Breaker
A
20
20
REFRIGERATION SYSTEM
Refrigerant
Compressor Type
Connections
Liquid Line O.D.
Suction Line O.D.
Factory Precharge
Max. Line Length
Max. Height Difference
DIMENSIONS & WEIGHT
WxHxD
INDOOR
Net Weight
UNIT
Shipping Weight
WxHxD
OUTDOOR
Net Weight
UNIT
Shipping Weight
in
in
ft
ft
ft
R410A
Inverter
Flare
1/4
3/8
98
Each unit:82 Total:98
33
in
lbs
lbs
in
lbs
lbs
31 1/8 x 10 7/8 x 8 1/2 ea.
21 ea.
26 ea.
35 3/8 x 32 5/8 x 13
151
164
Quad-zone heat pumps
M24DYF
2 x MW12Y3FM
MR24DY3F
12000 ea.
5100-13600
0.77
14000 ea.
5100-15400 ea.
10500 ea.
9.0
16.5
10.4
3.7 ea.
215/250/305/355
30/34/39/42
52
0 - 115 (14-75)
M36QYF
4 x MW09Y3FM
MR36TQY3F
8800 ea.
5100-11300
0.71
9500 ea.
5100-13000 ea.
6600 ea.
9.0
15.0
8.8
2.9 ea.
185/220/260/295
27/29/33/37
52
0 - 115 (14-75)
230/208-60-1
15
2300
20
230/208-60-1
22.5
3900
30
98
Each unit:82 Total:98
33
R410A
Inverter
Flare
1/4
3/8
98
Each unit:82 Total:98
33
R410A
Inverter
Flare
1/4
3/8
165
Each unit:82 Total:230
49
31 1/8 x 10 7/8 x 8 1/2 ea.
21
21
26
26
35 3/8 x 32 5/8 x 13
151
164
31 1/8 x 10 7/8 x 8 1/2 ea.
21 ea.
26 ea.
35 3/8 x 32 5/8 x 13
151
164
31 1/8 x 10 7/8 x 8 1/2 ea.
21 ea.
26 ea.
35 3/8 x 32 5/8 x 13
159
172
R410A
Inverter
Flare
1/4
3/8
1/4
3/8
Tri-zone heat pumps
PERFORMANCE RATINGS
M27TYF
M30TYF
SYSTEM MODEL NO.
INDOOR MODEL
3 x MW09Y3FM
2 x MW09Y3FM
MW12Y3FM
OUTDOOR MODEL
MR36TQY3F
MR36TQY3F
Capacity Cooling
BTU/h
9200 ea.
9300 ea.
11800
Capacity Cooling Min - Max
BTU/h
5100-11300
5100-11300
5100-13600
Sensible Heat Ratio
0.71
0.71
0.71
Capacity Heating @ 47°F
BTU/h
11200 ea.
11000 ea.
14000
Capacity Heating Min - Max
BTU/h
5100-13000
5100-13000
5100-15400
Capacity Heating @ 17°F
BTU/h
8300 ea.
7700 ea.
9800
HSPF
9.0
9.0
SEER
15.0
15.0
EER
10.0
9.2
Moisture Removal
Pts/h
2.9 ea.
2.9 ea.
3.7
Airflow (Quiet, Low, Med, High)
CFM
185/220/260/295
185/220/260/295 215/250/305/355
Sound Rating - Indoor
dB-A
27/29/33/37
27/29/33/37
30/34/39/42
Sound Rating - Outdoor
dB-A
52
52
Operating Range COOL (HEAT)
°F
0 - 115 (14-75)
0 - 115 (14-75)
ELECTRICAL DATA (all indoor units receive power from outdoor unit; values listed are total)
230/208-60-1
230/208-60-1
Power Source
Min. Ampacity
A
22.5
22.5
Cooling Watts
W
2710
3180
Max. TD Fuse/Breaker
A
30
30
REFRIGERATION SYSTEM
R410A
R410A
Refrigerant
Compressor Type
Inverter
Inverter
Connections
Flare
Flare
Liquid Line O.D.
in
1/4
1/4
Suction Line O.D.
in
3/8
3/8
Factory Precharge
ft
165
165
Max. Line Length
ft Each unit:82 Total:230
Each unit:82 Total:230
Max. Height Difference
ft
49
49
DIMENSIONS & WEIGHT
31 1/8 x 10 7/8 x 8 1/2 ea.
WxHxD
in 31 1/8 x 10 7/8 x 8 1/2 ea.
OUTDOOR
Net Weight
lbs
21 ea.
21 ea.
21
UNIT
Shipping Weight
lbs
26 ea.
26 ea.
26
35 3/8 x 32 5/8 x 13
35 3/8 x 32 5/8 x 13
WxHxD
in
OUTDOOR
Net Weight
lbs
159
159
UNIT
Shipping Weight
lbs
172
172
M33TYF
MW09Y3FM
2 x MW12Y3FM
MR36TQY3F
9400
11800 ea.
5100-11300
5100-13600
0.71
0.71
10700
13600 ea.
5100-13000
5100-15400
7200
9200 ea.
9.0
15.0
8.8
2.9
3.7 ea.
185/220/260/295
215/250/305/355
27/29/33/37
30/34/39/42
52
0 - 115 (14-75)
M36TYF1
2 x MW09Y3FM
MW18Y3FM
MR36TQY3F
9100 ea.
17000
5100-11300
5100-19000
0.71
0.71
9800 ea.
18400
5100-13000
5500-23000
6700 ea.
12500
9.0
15.0
8.8
2.9 ea.
5.7
185/220/260/295
240/290/355/415
27/29/33/37
33/39/42/46
52
0 - 115 (14-75)
M36TYF2
3 x MW12Y3FM
MR36TQY3F
11700 ea.
5100-15400
0.71
12700 ea.
5100-15400
8600 ea.
9.0
15.0
8.8
3.7 ea.
215/250/305/355
30/34/39/42
52
0 - 115 (14-75)
230/208-60-1
22.5
3710
30
230/208-60-1
22.5
4000
30
230/208-60-1
22.5
3980
30
R410A
Inverter
Flare
1/4
3/8
165
Each unit:82 Total:230
49
R410A
Inverter
Flare
165
Each unit:82 Total:230
49
R410A
Inverter
Flare
1/4
3/8
165
Each unit:82 Total:230
49
31 1/8 x 10 7/8 x 8 1/2
31 1/8 x 10 7/8 x 8 1/2
21 ea.
21
26 ea.
26
35 3/8 x 32 5/8 x 13
159
172
31 1/8 x 10 7/8 x 8 1/2
21 ea.
26 ea.
35 3/8 x 32 5/8 x 13
159
172
31 1/8 x 10 7/8 x 8 1/2
21
21 ea.
26
26 ea.
35 3/8 x 32 5/8 x 13
159
172
1/4
3/8
1/4
1/2
Ceiling and Floor/ceiling universal heat pumps
inverter model
floor/ceiling universal
ceiling suspended
ceiling cassette
Pts/h
CFM
dB-A
dB-A
°F
S24YF
MS24Y3F
MR24UY3F
22200
5000-27300
0.62
24200
5000-29000
15000
8.5
15.0
9.8
7.4
371/436/518
38/43/47
53
0 to 115 (14-75)
S36YF
MS36Y3F
MR36Y3F
34100
8500-36000
0.67
36400
9200-42700
23400
8.5
14.0
8.1
7.4
842/977/1089
41/45/48
54
0 to 115 (14-75)
C24YF
MC24Y3F
MR24UY3F
22200
5000-27300
0.64
24200
5000-29000
14600
8.5
15.0
10.6
6.4
436/536/618
38/43/45
53
0 to 115 (14-75)
A
W
A
230/208-60-1
15.5
2250
20
230/208-60-1
23
4220
30
230/208-60-1
15.5
2100
20
in
in
ft
ft
ft
R410A
Inverter (Twin Rotary)
Flare
3/8
5/8
50
165
66
R410A
Inverter (Twin Rotary)
Flare
3/8
5/8
50
165
98
R410A
Inverter (Twin Rotary)
Flare
3/8
5/8
50
165
66
in
lbs
lbs
in
lbs
lbs
39 x 7 7/8 x 25 3/4
62
82
35 3/8 x 32 5/8 x 13
141
154
65 3/8 x 9 1/2 x 27 1/2
106
134
35 3/8 x 32 5/8 x 13
141
154
32 5/8 x 9 5/8 x 32 5/8
75
97
35 3/8 x 32 5/8 x 13
141
154
PERFORMANCE RATINGS
SYSTEM MODEL NO.
INDOOR MODEL
OUTDOOR MODEL
Capacity Cooling
Capacity Cooling Min - Max
Sensible Heat Ratio
Capacity Heating @ 47°F
Capacity Heating Min - Max
Capacity Heating @ 17°F
HSPF
SEER
EER
Moisture Removal
Airflow (Low, Med, High)
Sound Rating - Indoor
Sound Rating - Outdoor
Operating Range COOL (HEAT)
BTU/h
BTU/h
BTU/h
BTU/h
BTU/h
ELECTRICAL DATA
Power Source
Min. Ampacity
Cooling Watts
Max. TD Fuse/Breaker
REFRIGERATION SYSTEM
Refrigerant
Compressor Type
Connections
Liquid Line O.D.
Suction Line O.D.
Factory Precharge
Max. Line Length
Max. Height Difference
DIMENSIONS & WEIGHT
INDOOR UNIT
OUTDOOR
UNIT
WxHxD
Net Weight
Shipping Weight
WxHxD
Net Weight
Shipping Weight
Refrigeration line sets
USED WITH:
All 9000 and 12000 BTU/h
Indoor Units
All 18000 BTU/h Indoor Units
All MW24Y3F and MW24C3F Units
All 30000 BTU/h Indoor Units and S24YF,
S36YF and C24YF Units
LENGTH-FT.
LIQUID
SUCTION
KIT#
15
1/4”
3/8”
T32150
35
1/4”
3/8”
T32350
15
1/4”
1/2”
T42150
35
1/4”
1/2”
T42350
15
1/4”
5/8”
T52150
35
1/4”
5/8”
T52350
15
3/8”
5/8”
T53150
35
3/8”
5/8”
T53350
Insulated line sets are available for all Friedrich split systems in 15 ft. and 35 ft. lengths. Each line set is equipped with flare nuts on both ends. Both liquid and
suction lines are insulated. Line sets can be joined together with field supplied double female connectors. Each system requires one line set for each indoor
unit installed. On multi-zone systems, line sets should be ordered based on individual indoor unit capacities not total system capacity. For example, a M18DYF
uses 2 line sets for 9,000 btu units, not 1 for the 18,000 btu product.
DRAIN PUMP
USED WITH
DP-36
S36YF
NOTE: All models have low ambient capabilities built-in. Capacity is reduced as 0 degrees Fahrenheit is approached.
NOTE: All R410A models have 1/2˝ UNF 20 thread per inch charging and vacuuming ports. An adapter must be used
for 1/4˝ gauges. Adapter part number 67270018 is available through Friedrich parts distributors.
R-410A
All models use
environmentally
friendly R-410A
refrigerant.
Friedrich Air Conditioning Co. | P.O. Box 1540 | San Antonio, TX 78295-1540 | (800) 541-6645 | fax (210) 357-4480 | www.friedrich.com
DSS-09
Printed in USA