Friedrich PDH15R5SG Spec Sheet

Friedrich PDH15R5SG Spec Sheet
Product Profile
PACKAGED TERMINAL
AIR CONDITIONERS
Features
• Tangential blower wheel for
fast, powerful and even air
distribution
• Two permanently-lubricated
fan motors for quiet
operation
• EERs up to 12.2; COPs up
to 3.4
• 3 heating and cooling fan
speeds
• Separate thermostat
settings (limiting) for
cooling and heating modes
allow for improved comfort
• Internal diagnostic program
• Fits standard PTAC sleeve
without added cost of a
baffle kit
• Wireless or wired remote
thermostat operation
• Desk control ready
• 2-yr. parts and labor
warranty; 5-yr. limited
warranty (see warranty
document on back page for
full details)
• Compatible with energy
management systems
• Reversible indoor air
louvers
• Condensate removal
system uses slinger ring
technology to cool the coil
and increase efficiency
• Antimicrobial air filters
• Modular design ensures
easy access to key
components
Protects the outdoor coil against
deterioration and extends the
life of the unit especially in
harsh coastal environments.
PTAC_Product_Profile_2014
Product Features
Product Features
DIGITAL TEMPERATURE
READOUT
DIAMONBLUE™
TECHNOLOGY
Diamonblue anticorrosive coating protects the outdoor coil from harsh environments. Standard on all
models.
DIGITAL DEFROST
THERMOSTAT
The PD Series uses a digital thermostat to accurately monitor the outdoor coil conditions to allow the
heat pump to run whenever conditions are correct. Running the PTAC in heat pump mode saves energy
and reduces operating costs. The digital thermostat allows maximization of heat pump run time.
INSTANT HEAT
HEAT PUMP MODE
Heat pump models will automatically run the electric heater to quickly bring the room up to temperature
when initially energized, then return to heat pump mode. This ensures that the room is brought up to
temperature quickly without the usual delay associated with heat pump units.
EVEN HEAT MONITORING
The digital control monitors indoor conditions, ensuring room temperature is within 5° F of the setpoint. If
needed, the unit will briefly cycle the electric heater to maintain temperature. This feature preserves the
efficiency benefits of a heat pump while ensuring guest comfort.
ONE-TOUCH
OPERATION
When the unit is powered off, the unit can be returned directly to heating or cooling mode by pressing the
‘Heat’ or ‘Cool’ buttons without the confusing power up sequence of some controls. One-touch control
takes the guesswork out of unit control, delivering a more enjoyable experience and eliminating front-desk
calls.
INDIVIDUAL MODE
& FAN CONTROL
BUTTONS
By having separate control buttons and indicators for both fan and mode settings, the Friedrich digital
control eliminates the confusion of previous digital PTACs. The accurate temperature setting provides
greater guest comfort than other systems.
QUIET START/STOP
FAN DELAY
The fan start and stop delays prevent abrupt changes in room acoustics due to the compressor energizing or stopping immediately. Upon call for cooling or heating, the unit fan will run for five seconds prior to
energizing the compressor. Also, the fan-off delay allows for “free cooling” by utilizing the already cool
indoor coil to its maximum capacity by running for 30 seconds after the compressor.
SEPARATE HEAT/COOL
FAN CYCLE
CONTROL
The owner may choose between fan cycling or fan continuous mode based on property preference. (Note:
Even heat monitoring and quiet start/stop fan delay only operate in fan cycle mode) Fan continuous mode is
used to keep constant airflow circulation in the room during all times the unit is ‘ON’. Fan cycle will conserve
energy by only operating the fan while the compressor or electric heater is operating. The ability to set the
fan cycling condition independently between heating and cooling mode will increase user comfort by
allowing the choice of only constantly circulating air in the summer or winter time (unlike other PTAC
brands that only allow one selection).
REMOTE THERMOSTAT
OPERATION
Some applications require the use of a wall-mounted thermostat. All new Friedrich PTACs may be
switched from unit control to remote thermostat control easily without the need to order a special model
or accessory kit.
EMERGENCY
HEAT OVERRIDE
In the event of a compressor failure in heat pump mode, the compressor may be locked out to provide
heat through the resistance heater. This feature ensures that even in the unlikely event of a compressor
failure, the room temperature can be maintained until the compressor can be serviced.
INTERNAL DIAGNOSTIC
PROGRAM
The Friedrich digital PTAC features a self-diagnostic program that can alert maintenance to component
failures or operating problems. The internal diagnostic program saves properties valuable time when
diagnosing running problems.
DESK CONTROL
READY
All Friedrich digital PTACs have low voltage terminals ready to connect a desk control energy management system. Controlling the unit from a remote location like the front desk can reduce energy usage and
requires no additional accessories on the PTAC unit.
INDOOR COIL
FROST SENSOR
The frost sensor protects the compressor from damage in the event that airflow is reduced or low outdoor
temperatures cause the indoor coil to freeze. When the indoor coil reaches 30°F, the compressor is
disabled and the fan continues to operate based on demand. Once the coil temperature returns to 45°F,
the compressor returns to operation.
ULTRAQUIET
AIR SYSTEM
The PD- series units feature an indoor fan system design that reduces sound levels without lowering
airflow or preventing proper air circulation.
HIGH EFFICIENCY
The Friedrich PTAC has been engineered so that all functional systems are optimized so that they work
together to deliver the highest possible performance.
DUAL MOTOR
The dual-motor design means that the indoor motor can run at slower speeds which reduces sound
levels indoors.
When the PTAC senses that the indoor room temperature has fallen to 40°F, the unit will cycle on the
fan (high) and the electric strip heat to raise the room temperature to 46°F, and then cycle off again. This
feature works regardless of the mode selected and can be turned off. The control will also store the Room
Freeze cycle in the service code memory for retrieval at a later date. This feature ensures that unoccupied
rooms do not reach freezing levels where damage can occur to plumbing and fixtures.
ROTARY COMPRESSOR
High efficiency rotary compressors are used on all Friedrich PTACs to maximize durability and efficiency.
STAINLESS STEEL
ENDPLATES
Outdoor coil endplates made from stainless steel reduce corrosion on the outdoor coil common with other
coil designs.
RANDOM COMPRESSOR
RESTART
Multiple compressors starting at once can often cause electrical overloads and premature unit failure.
The random restart delay eliminates multiple units from starting at once following a power outage or initial
power up. The compressor delay will range from 180 to 240 seconds.
TOP-MOUNTED
ANTIMICROBIAL
AIR FILTERS
All Friedrich PTAC return air filters feature an antimicrobial element that has proven to prevent mold and
bacterial growth in laboratory testing. PDXFT replacement filter kits feature the same antimicrobial agent.
All filters are washable, reusable and easily accessed from the top of the unit without the removal of the
front cover.
CONDENSATE REMOVAL
SYSTEM
Condenser fan utilizes slinger ring technology to pick up condensate from the base pan and disperse it
on to the condenser coil where it evaporates. This helps to cool the coil and increase the energy efficiency
of the unit.
FILTERED FRESH
AIR INTAKE
Friedrich PTAC units are capable of introducing up to 75 CFM of outside air into the conditioned space.
The outdoor air passes through a washable mesh screen to prevent debris from entering the airstream.
R-410A REFRIGERANT
Friedrich PTAC units use environmentally-friendly refrigerant.
SERVICE ERROR CODE
STORAGE
ELECTRONIC
TEMPERATURE
LIMITING
ROOM FREEZE
PROTECTION
2
By digitally monitoring the desired room temperature, the room is controlled more precisely than conventional systems. The large, easy-to-read LED display can show either the set point or actual room
temperature as selected by owner.
All Friedrich PTAC units have self-diagnostic features that will store trouble codes in the case of an event.
Storing the codes allows the property to see the trouble codes at a future time after the condition may
have corrected.
By limiting the operating range, the property can save energy by eliminating “max cool” or “max heat” situations common with older uncontrolled systems. The new electronic control allows owners to set operating ranges for both heating and cooling independently of one another.
3
Chassis Specifications
Cooling & Heating Performance
PDE Series
PDE 230V - Extended Cooling Performance
PERFORMANCE DATA:
COOLING Btu
POWER (WATTS)
EER
DEHUMIDIFICATION (pints/hr)
SENSIBLE HEAT RATIO
ELECTRICAL DATA:
VOLTAGE (1 PHASE, 60 Hz)
VOLT RANGE
CURRENT (AMPS)
POWER FACTOR
Compressor LRA
Compressor RLA
Fan motor horsepower
AIRFLOW DATA:
INDOOR CFM, HIGH
INDOOR CFM, MED
INDOOR CFM, LOW
VENT CFM
PHYSICAL DATA:
DIMENSIONS (H x W x D)
NET WEIGHT (lbs.)
SHIPPING WEIGHT (lbs.)
R-410A CHARGE (oz)
Dim.s w/ Pkg. (inches)
PDE07K
PDE07R
PDE09K
PDE09R
PDE12K
PDE12R
PDE15K
PDE15R
7700/7600
640/620
12.0/12.2
1.7
0.84
7700
640
12.0
1.7
0.84
9000/8800
800/770
11.3/11.4
2.2
0.81
9000
800
11.3
2.2
0.81
12000/11800
1120/1120
10.7/10.5
2.7
0.67
12000
1120
10.7
2.7
0.67
15000/14600
1530/1510
9.8/9.7
3.2
0.65
15000
1530
9.8
3.2
0.65
230/208
253-187
2.8/3.0
0.97
19.0
2.8
0.024
265
292-239
2.4
0.99
12.0
2.4
0.024
230/208
253-187
3.7/3.9
0.99
17.0
3.7
0.029
265
292-239
3.7
0.99
18.0
2.9
0.029
230/208
253-187
5.1/5.3
0.99
27.0
5.0
0.031
265
292-239
4.8
0.99
23.0
4.3
0.031
230/208
253-187
6.7/7.5
0.99
32.6
6.6
0.031
265
292-239
5.9
0.99
27.8
5.6
0.031
345/315
320/290
295/265
75
345
320
295
75
360/345
330/305
300/270
75
360
330
300
75
360/350
330/310
310/280
75
360
330
310
75
385/375
360/330
320/290
75
385
360
320
75
106
126
23.63
106
126
24.69
111
131
33.51
119
139
38.10
119
139
40.21
16 x 42 x 13 3/4 (all models)
111
116
116
131
136
136
33.51
35.27
35.98
19 3/4 x 23 x 43 1/2 (all models)
OUTDOOR DRY BULB TEMP. (DEGREES F AT 40% R.H.)
75
PDE07
PDE09
PDE12
PDE15
Btu
WATTS
AMPS
SHR
Btu
WATTS
AMPS
SHR
Btu
WATTS
AMPS
SHR
Btu
WATTS
AMPS
SHR
PDH07R
PDH09K
PDH09R
PDH12K
PDH12R
PDH15K
PDH15R
7700/7600
640/620
12.0/12.2
6300/6100
540/530
3.4/3.4
1.7
0.84
7700
640
12.0
6300
540
3.4
1.7
0.84
9000/8800
800/770
11.3/11.4
8100/7900
720/770
3.3/3.3
2.2
0.81
9000
800
11.3
8100
720
3.3
2.2
0.81
12000/11800
1120/1120
10.7/10.5
10700/10500
1010/990
3.1/3.1
2.7
0.67
12000
1120
10.7
10700
1010
3.1
2.7
0.67
14500/14200
1480/1460
9.8/9.7
13300/13000
1300/1270
3.0/3.0
3.2
0.65
14500
1480
9.8
13300
1300
3.0
3.2
0.65
230/208
253-187
2.8/3.0
2.4/2.5
0.97
19.0
2.8
0.024
265
292-239
2.4
2.1
0.99
12.0
2.4
0.024
230/208
253-187
3.7/3.9
3.4/3.8
0.99
18.5
3.6
0.029
265
292-239
3.7
3.4
0.99
19.0
3.2
0.029
230/208
253-187
5.1/5.3
4.5/4.7
0.99
27.0
5.0
0.031
265
292-239
4.8
4.5
0.99
23.0
4.3
0.031
230/208
253-187
6.7/7.5
5.8/6.2
0.98
36.0
6.6
0.031
265
292-239
5.7
5.0
0.98
26.0
5.3
0.031
345/315
320/290
295/265
75
345
320
295
75
360/345
330/305
300/270
75
360
330
300
75
360/350
330/310
310/280
75
360
330
310
75
420/390
410/380
380/350
75
385
360
320
75
108
128
23.63
108
128
24.69
16 x 42 x 13 3/4 (all models)
113
118
133
138
35.27
35.27
113
133
33.51
121
141
39.86
121
141
36.33
Due to continuing research in new energy-saving technology, specifications are subject to change without notice.
Voltage
Heater Size
230V
15
20
PDH07
PDH09
PDH12
PDH15
0, 2.0 kW 3.0 kW
15
20
30
5.0 kW
2.0 kW
3.0 kW
5.0 kW
4
NEMA#
Receptacle
6-15R
6-20R
6-30R
7-15R
7-20R
7-30R
NEMA#
Plug
6-15P
6-20P
6-30P
7-15P
7-20P
7-30P
62
8062
536
2.4
0.96
9423
670
3.1
0.89
12564
939
4.3
0.89
15705
1282
5.6
0.85
72
8624
569
2.5
0.54
10080
711
3.3
0.50
13440
996
4.5
0.50
16800
1360
6.0
0.48
LISTED
67
8131
575
2.5
0.74
9504
718
3.3
0.69
12672
1006
4.6
0.69
15840
1374
6.0
0.66
62
7500
582
2.5
0.98
8766
727
3.3
0.91
11688
1018
4.6
0.91
14610
1391
6.0
0.87
72
8285
640
2.8
0.54
9684
800
3.7
0.50
12912
1120
5.1
0.50
16140
1530
6.7
0.48
67
7700
640
2.86
0.77
9000
800
3.7
0.71
12000
1120
5.1
0.71
15000
1530
6.7
0.68
62
6815
640
2.8
0.99
7965
800
3.7
0.91
10620
1120
5.1
0.91
13275
1530
6.7
0.87
72
7762
692
3.0
0.55
9072
865
4.0
0.51
12096
1211
5.5
0.51
15120
1654
7.2
0.49
67
6892
691
3.0
0.81
8055
864
4.0
0.75
10740
1210
5.5
0.75
13425
1652
7.2
0.72
62
6075
693
3.0
0.99
7101
866
4.0
0.92
9468
1213
5.5
0.92
11835
1657
7.2
0.88
72
6907
755
3.3
0.58
8073
943
4.3
0.54
10764
1320
6.0
0.54
13455
1804
7.9
0.51
67
5944
755
3.3
0.87
6948
943
4.3
0.80
9264
1320
6.0
0.80
11580
1804
7.9
0.77
62
5251
758
3.3
0.99
6138
947
4.4
0.91
8184
1326
6.0
0.91
10230
1812
7.9
0.87
Btu
WATTS
AMPS
SHR
Btu
WATTS
AMPS
SHR
Btu
WATTS
AMPS
SHR
Btu
WATTS
AMPS
SHR
72
9055
522
2.3
0.53
10584
653
3.1
0.49
14112
914
4.2
0.49
17052
1208
5.4
0.48
67
8709
531
2.3
0.72
10179
663
3.1
0.66
13572
928
4.2
0.66
16400
1227
5.5
0.65
OUTDOOR DRY BULB TEMP. (DEGREES F AT 40% R.H.)
95
INDOOR WET BULB TEMP. (DEGREES F AT 80 F D.B.)
67
62
72
67
62
72
8131
7500
8285
7700
6815
7762
575
582
640
640
640
692
2.5
2.5
2.8
2.8
2.8
.03
0.74
0.98
0.54
0.77
0.99
0.55
9504
8766
9684
9000
7965
9072
865
718
727
800
800
800
3.3
3.3
3.7
3.7
3.7
4.0
0.69
0.91
0.50
0.71
0.91
0.51
12672
11688
12912
12000
10620
12096
1006
1018
1120
1120
1120
1211
4.6
4.6
5.1
5.1
5.1
5.5
0.69
0.91
0.50
0.71
0.91
0.51
15312
14123
15602
14500
12833
14616
1329
1345
1480
1480
1480
1600
5.9
5.9
6.5
6.6
6.6
7.1
0.68
0.89
0.49
0.70
0.90
0.50
85
62
8062
536
2.4
0.96
9423
670
3.1
0.89
12564
939
4.3
0.89
15182
1240
5.5
0.88
72
8624
569
2.5
0.54
10080
711
3.3
0.50
13440
996
4.5
0.50
16240
1316
5.9
0.49
105
67
6892
691
3.0
0.81
8055
864
4.0
0.75
10740
1210
5.5
0.75
12978
1598
7.1
0.74
110
62
6075
693
3.0
0.99
7101
866
4.0
0.92
9468
1213
5.5
0.92
11441
1603
7.1
0.90
72
6907
755
3.3
0.58
8073
943
4.3
0.54
10764
1320
6.0
0.54
13007
1745
7.7
0.53
67
5944
755
3.3
0.87
6948
943
4.3
0.8
9264
1320
6.0
0.80
11194
1745
7.7
0.79
62
5251
758
3.3
0.99
6138
947
4.4
0.91
8184
1326
6.0
0.91
9889
1752
7.7
0.90
Extended Heating Performance
OUTDOOR DRY BULB TEMP. (DEGREES F)
PDH09
PDH15
ROOM AIR CONDITIONERS
183H
Receptacles
67
8709
531
2.3
0.72
10179
663
3.1
0.66
13572
928
4.2
0.66
16965
1268
5.6
0.63
RATING POINT
ARI 310/380
PDH12
265V
30
110
PDH 230V - Extended Cooling Performance
RECEPTACLES AND FUSE TYPES
Amps
105
RATING POINT
ARI 310/380
PDH07
118
138
35.98
72
9055
522
2.3
0.53
10584
653
3.1
0.49
14112
914
4.2
0.49
17640
1248
5.5
0.47
75
PDH07K
95
INDOOR WET BULB TEMP. (DEGREES F AT 80 F D.B.)
PDH Series
PERFORMANCE DATA:
COOLING Btu
POWER (WATTS) cool
EER
REVERSE HEATING Btu
POWER (WATTS) HEAT
COP
DEHUMIDIFICATION (pints/hr)
SENSIBLE HEAT RATIO
ELECTRICAL DATA:
VOLTAGE (1 PHASE, 60 Hz)
VOLT RANGE
CURRENT (AMPS)
REVERSE HEAT. Amps
POWER FACTOR
Compressor LRA
Compressor RLA
Fan motor horsepower
AIRFLOW DATA:
INDOOR CFM, HIGH
INDOOR CFM, MED
INDOOR CFM, LOW
VENT CFM
PHYSICAL DATA:
DIMENSIONS (H x W x D)
NET WEIGHT (lbs.)
SHIPPING WEIGHT (lbs.)
R-410A CHARGE (oz)
85
37
42
47
52
57
Btu
5250
5540
6300
6900
7620
WATTS
509
518
540
549
580
AMPS
2.3
2.4
2.4
2.5
2.6
Btu
6005
6399
8100
8647
9245
WATTS
647
656
720
725
735
AMPS
3.3
3.3
3.4
3.4
3.5
Btu
7726
8531
10700
11278
12234
WATTS
883
917
1010
1039
1073
AMPS
4
4.1
4.5
4.7
4.9
Btu
10530
10850
13300
14550
15940
WATTS
1197
1212
1300
1377
1439
AMPS
5.3
5.4
5.8
6.1
6.3
RATING POINT
ARI 310/380
5
Cooling & Heating Performance
Electric Heat Data
PDE 265V - Extended Cooling Performance
Electric Heat Data
OUTDOOR DRY BULB TEMP. (DEGREES F AT 40% R.H.)
75
85
95
105
PDE07K0
110
HEATER WATTS
INDOOR WET BULB TEMP. (DEGREES F AT 80 F D.B.)
PDE07
PDE09
PDE12
PDE15
72
67
62
72
67
62
72
67
62
72
67
62
72
67
62
Btu
9055
8709
8062
8624
8131
7500
8285
7700
6815
7762
6892
6075
6907
5944
5251
WATTS
522
531
536
569
575
582
640
640
640
692
691
693
755
755
758
0 Kw
2000
1635
3000
2450
230/208
230
208
230
208
HEATING Btu
0
6824
5580
10236
8360
6824
10236
0
8.9
7.9
13.2
12.2
7.6
11.4
VOLTAGE
2.0
2.0
2.0
2.1
2.1
2.2
2.4
2.4
2.4
2.6
2.6
2.6
2.8
2.8
2.8
HEATING CURRENT (AMPS)
0.72
0.96
0.54
0.74
0.98
0.54
0.77
0.99
0.55
0.81
0.99
0.58
0.87
0.99
Btu
10584
10179
9423
10080
9504
8766
9684
9000
7965
9072
8055
7101
8073
6948
6138
MINIMUM CIRCUIT AMPACITY
4.0
11.4
10.0
16.8
15.6
9.6
14.6
653
663
670
711
718
727
800
800
800
865
864
866
943
943
947
BRANCH CIRCUIT FUSE (AMPS)
15
15
15
20
20
15
20
0 Kw
2000
1635
3000
2450
5000
4090
230/208
230
208
230
208
230
208
0
6824
5580
10236
8360
17060
13960
6824
WATTS
AMPS
3.1
3.1
3.1
3.3
3.3
3.3
3.7
3.7
3.7
4.0
4.0
4.0
4.3
4.3
4.4
SHR
0.49
0.66
0.89
0.50
0.69
0.91
0.50
0.71
0.91
0.51
0.75
0.92
0.54
0.80
0.91
Btu
14112
13572
12564
13440
12672
11688
12912
12000
10620
12096
10740
9468
10764
9264
8184
WATTS
914
928
939
996
1006
1018
1120
1120
1120
1211
1210
1213
1320
1320
1326
AMPS
4.0
4.0
4.0
4.3
4.3
4.3
4.8
4.8
4.8
5.2
5.2
5.2
5.6
5.6
5.7
SHR
0.49
0.66
0.89
0.50
0.69
0.91
0.50
0.71
0.91
0.51
0.75
0.92
0.54
0.80
0.91
Btu
17640
16965
15705
16800
15840
14610
16140
15000
13275
15120
13425
11835
13455
11580
10230
WATTS
1248
1268
1282
1360
1374
1391
1530
1530
1530
1654
1652
1657
1804
1804
1812
AMPS
4.9
4.9
5.0
5.3
5.3
5.3
5.9
5.9
5.9
6.3
6.3
6.4
6.9
6.9
7.0
SHR
0.47
0.63
0.85
0.48
0.66
0.87
0.48
0.68
0.87
RATING POINT
ARI 310/380
0.49
0.72
0.88
0.51
0.77
0.87
85
95
105
Electric Heat Data
PDE09K0
HEATER WATTS
VOLTAGE
HEATING Btu
HEATING CURRENT (AMPS)
67
62
72
67
62
72
67
62
72
67
62
72
67
62
Btu
9055
8709
8062
8624
8131
7500
8285
7700
6815
7762
6892
6075
6907
5944
5251
PDH12
PDH15
6
3000
5000
265
10236
17060
0
8.9
7.9
13.2
12.2
21.5
20.5
7.6
11.4
19.0
5.2
11.4
10.0
16.8
15.6
27.2
14.6
9.8
14.6
24.1
BRANCH CIRCUIT FUSE (AMPS)
15
15
15
20
20
30
30
15
20
30
PDE12K0
HEATER WATTS
PDE/PDH12K
PDE/PDH12R
0 Kw
2000
1635
3000
2450
5000
4090
230/208
230
208
230
208
230
208
2000
3000
5000
WATTS
522
531
536
569
575
582
640
640
640
692
691
693
755
755
758
VOLTAGE
AMPS
2.0
2.0
2.0
2.1
2.1
2.2
2.4
2.4
2.4
2.6
2.6
2.6
2.8
2.8
2.8
SHR
0.53
0.72
0.96
0.54
0.74
0.98
0.54
0.77
0.99
0.55
0.81
0.99
0.58
0.87
0.99
HEATING Btu
0
6824
5580
10236
8360
17060
13960
6824
10236
17060
Btu
10584
10179
9423
10080
9504
8766
9684
9000
7965
9072
8055
7101
8073
6948
6138
HEATING CURRENT (AMPS)
0
8.9
7.9
13.2
12.2
21.5
20.5
7.6
11.4
19.0
WATTS
653
663
670
711
718
727
800
800
800
865
864
866
943
943
947
AMPS
3.1
3.1
3.1
3.3
3.3
3.3
3.7
3.7
3.7
4.0
4.0
4.0
4.3
4.3
4.4
MINIMUM CIRCUIT AMPACITY
7.1
11.4
10.0
16.8
15.6
27.2
14.6
9.8
14.6
24.1
SHR
0.49
0.66
0.89
0.50
0.69
0.91
0.50
0.71
0.91
0.51
0.75
0.92
0.54
0.80
0.91
BRANCH CIRCUIT FUSE (AMPS)
15
15
15
20
20
30
30
15
20
30
Btu
14112
13572
12564
13440
12672
11688
12912
12000
10620
12096
10740
9468
10764
9264
8184
WATTS
914
928
939
996
1006
1018
1120
1120
1120
1211
1210
1213
1320
1320
1326
AMPS
4.0
4.0
4.0
4.3
4.3
4.3
4.8
4.8
4.8
5.2
5.2
5.2
5.6
5.6
5.7
SHR
0.49
0.66
0.89
0.50
0.69
0.91
0.50
0.71
0.91
0.51
0.75
0.92
0.54
0.80
0.91
Btu
17052
16400
15182
16240
15312
14123
15602
14500
12833
14616
12978
11441
13007
11194
9889
WATTS
1208
1227
1240
1316
1329
1345
1480
1480
1480
1600
1598
1603
1745
1745
1752
AMPS
4.7
4.7
4.8
5.1
5.1
5.1
5.7
5.7
5.7
6.1
6.1
6.2
6.7
6.7
6.7
SHR
0.48
0.65
0.88
0.49
0.68
0.89
0.49
0.70
0.90
RATING POINT
ARI 310/380
0.50
0.74
0.90
0.53
0.79
0.90
OUTDOOR DRY BULB TEMP. (DEGREES F)
PDH09
PDE/PDH09R
2000
Electric Heat Data
110
72
Extended Heating Performance
PDH07
PDE/PDH09K
MINIMUM CIRCUIT AMPACITY
INDOOR WET BULB TEMP. (DEGREES F AT 80 F D.B.)
PDH15
3000
265
0.53
OUTDOOR DRY BULB TEMP. (DEGREES F AT 40% R.H.)
PDH12
2000
AMPS
75
PDH09
PDE/PDH07R
SHR
PDH 265V - Extended Cooling Performance
PDH07
PDE/PDH07K
37
42
47
52
57
Btu
5250
5540
6300
6900
7620
WATTS
509
518
540
549
580
AMPS
2.3
2.4
2.4
2.5
2.6
Btu
6005
6399
8100
8647
9245
WATTS
647
656
720
725
735
AMPS
3.3
3.3
3.4
3.4
3.5
Btu
7726
8531
10700
11278
12234
WATTS
883
917
1010
1039
1073
AMPS
4.0
4.1
4.5
4.7
4.9
Btu
10530
10850
13300
14550
15940
WATTS
1197
1212
1300
1377
1439
AMPS
4.5
4.6
5.0
RATING POINT
ARI 310/380
5.3
5.5
265
Electric Heat Data
PDE15K0
HEATER WATTS
VOLTAGE
0 Kw
PDE/PDH15K
2000
1635
3000
2450
PDE/PDH15R
5000
4090
2000
3000
5000
230/208
230
208
230
208
230
208
HEATING Btu
0
6824
5580
10236
8360
17060
13960
6824
10236
265
17060
HEATING CURRENT (AMPS)
0
8.9
7.9
13.2
12.2
21.5
20.5
7.6
11.4
19.0
MINIMUM CIRCUIT AMPACITY
9.1
11.4
10.0
16.8
15.6
27.2
26.0
9.8
14.6
24.1
BRANCH CIRCUIT FUSE (AMPS)
15
15
15
20
20
30
30
15
20
30
7
PTAC
Model Identification / Components / Dimensions
Cooling Only, Electric Heat, Heat Pump
PTAC/PTHP Model Identification Guide
PD H 07 K
3
S
F A
Series
PD = Friedrich Digital PTAC
Engineering Digit
Design Series
System
X = Accessory
E = Cooling with or without electric heat
H = Heat Pump with auxiliary heat
Note: All PTAC models with a C design series
or later come standard with Diamonblue
seacoast protection and digital controls.
P.O. #
PROJECT
LOCATION
ENGINEER
ARCHITECT
SUBMITTED BY
FOR APPROVAL
Chassis
S
=
Standard
NOMINAL CAPACITY
07 = 7,000 Btu
09 = 9,000 Btu
PURCHASER
12 = 12,000 Btu
15 = 15,000 Btu
ITEM
PLAN DESIGNATION
QUANTITY
DATE
FOR REFERENCE
COOLING Btu
VOLTAGE
FRIEDRICH MODEL
Nominal Heater Size (@ 230V or 265V)
0 = No Heater*
2 = 2.0 KW
3 = 3.0 KW
VOLTAGE
K = 230/208V - 1 Ph. - 60 Hz.
R = 265V - 1 Ph. - 60 Hz.
5 = 5.0 KW**
* No heater only available on 230V PDE models
** 5.0 kw only available on 9000, 12000 and 15000 Btu models
Accessories
Typical Unit Components and Dimensions
Wall Sleeve
Outdoor Louver
Filters
PDXWS Wall Sleeve Dimensions:
16" H x 42" W x 13 ¾" D
Front Cover Dimensions:
16" H x 42" W x 7 ¾" D
Cut-Out Dimensions:
16 ¼" x 42 ¼"
Return Air Grille
Chassis
Front Cover
PDXWS
Wall Sleeve
PDXWSEXT18
Deep Wall Sleeve- For walls up to 17
1/2" deep
Qty
Qty
PDXWSEXT24
Deep Wall Sleeve- For walls up to 23
1/2" deep
Qty
PDXWSEXT
Custom Deep Wall Sleeve, For walls
from 13 1/4" to 25 1/2" deep
Qty
PXGA
Standard Outdoor Louver
PXAA
PXSB23020
Electrical Subbase - 230V 15A and 20A
Qty
PXSB23030
Electrical Subbase - 230V 30A
Qty
PXSB26515
Electrical Subbase - 265V 15A
Qty
PXSB26520
Electrical Subbase - 265V 20A
Qty
PXSB26530
Electrical Subbase - 265V 30A
Qty
PXPC23000
LCDI 230V 15A Cord, 0kw
Qty
Qty
PXPC23015
LCDI 230V 15A Cord, 2kW
Qty
Architectural Louver, clear
Qty
PXPC23020
LCDI 230V 20A Cord, 3kW
Qty
PXBG
Architectural Louver, beige
Qty
PXPC23030
LCDI 230V 30A Cord, 5kW
Qty
PXSC
Architectural Louver, color matched
Qty
PXPC26515
Non-LCDI 265V 15A Cord, 2kW
Qty
PDXRTA
Remote Thermostat Escutcheon Kit
Qty
PXPC26520
Non-LCDI 265V 20A Cord, 3kW
Qty
PXDR10
Condensate Drain Kit (pkg/10)
Qty
PXPC26530
Non-LCDI 265V 30A Cord, 5kW
Qty
PXSBA
Sub Base
Qty
RT6
Wired Digital Thermostat
Qty
PXSE
T-Series Sleeve Adapter
Qty
WRT1
Wireless Digital Thermostat
Qty
PXCJA
Conduit Kit w/Junction Box
Qty
EMRT1
Wired Thermostat with Occupancy Sensor
Qty
PDXDAA
Lateral Duct Adapter
Qty
EMWRT1
Wireless Thermostat with Occupancy Sensor
Qty
PDXDEA
Lateral Duct Extension
Qty
EMOCT
Online Connection Kit
Qty
EMRAF
Remote Access Fee
Qty
PXFTA
Replacement Filters (Set of 10)
Qty
Features
Constant room comfort monitoring
Durable, powder coat paint finish
“Instant Heat” heat pump mode quickly
heats a room to the desired temperature for
increased comfort
Indoor coil frost sensor protects the
compressor to lengthen the life of the unit.
Even heat monitoring checks room
temperature and automatically adds heat
boost if necessary
Room freeze protection- heat initiated if
temperature falls to 40°F in an unoccupied
room, raising temperature to 46°F
Dual motors for quiet operation
Random compressor restart protects
electrical systems from overload when
power is restored
Electronic defrost control ensures more run
time in the efficient heat pump mode
Universal heaters with heat capacities
determined by the power cord used with the unit
Fresh air damper control to bring in fresh
outside air when desired
Separate heat and cool range limits
Washable, antimicrobial air filter
Desk control ready allowing hotel owners
to control units from a central location
Service error code memory storage
Condensate removal systems uses slinger
ring technology
Diamonblue™ Advanced Corrosion Protection
Emergency heat override
PTAC_SUBMITTAL_14
8
9
Installation
Accessory Installation
Typical Wall Sleeve Installation (PDXWS)
Internal Drain Kit Location and Installation (PXDR10)
SCREW
ELECTRICAL
RECEPTACLE
42-¼"
MIN.
LINTEL TO SUPPORT
MASONRY WALLS
16-¼"
WALL SLEEVE
OPTIONAL AREA
60"
MAX.
GASKET
PREFERRED AREANO FOAM INSULATION
MOUNTING
PLATE
DRAIN TUBE
20"
MAX.
SMOOTH SIDE OF SCREW
CLIP FACING INTO ROOM
13-¾"
INSULATION
ELECTRICAL
RECEPTACLE
NUT
SIDE VIEW
IF THE DRAIN MUST BE
LOCATED IN THE OPTIONAL
AREA, THE FOAM INSULATION
MUST BE CUT AWAY AND
REMOVED TO ALLOW ACCESS
TO THE DRAIN.
PXDR10 DRAIN KIT
3"
WALL OPENING
WALL SLEEVE
FRONT VIEW
INSULATION
FRP011
NOTE: All 230/208V units are manufactured with a 72” power cord and all 265V units with a 20” power cord.
MAIN STUDS
JACK STUDS
FRP008
External Drain
COVER
PLATE
LINTEL
JACK STUDS
MOUNTING
SCREW HOLES
MAIN STUDS
Note the use of a lintel under the first course
of bricks above the wall sleeve. Do not use
the wall sleeve as a lintel. The mounting
screw holes shown are to be made by the
installer.
Note: All 230/208V units are manufactured
with a 60" power cord and all 265V units with
an 18" power cord. The receptacle locations
above must be followed to ensure proper
connections.
NO HOLES IN BOTTOM OF WALL
SLEEVE UNLESS DRAIN KIT IS USED
NOTE: Construct wall opening to comply with all applicable building codes.
FRP010
Deep Wall Sleeve Installation
When using an external drain system, the condensate is removed
through either of two drain holes
on the back of the wall sleeve.
Select the drain hole which best
meets your drainage situation and
install the drain kit. Seal off the
other with a cover plate.
Place the drain tube through the
gasket and the mounting plate with
the flange toward the wall sleeve.
Attach the drain tube assembly to
one of the two drain holes at the
rear of the wall sleeve. The large
flange on the mounting plate is positioned at the bottom of the sleeve
facing toward the sleeve. When
the drain tube is positioned at the
desired angle, tighten the screws.
MOUNTING
PLATE
OVERFLOW
SLOTS
10
of W
all
DETAIL B
½” O.D. TUBE
FRP012
INSTALLATION
1. Screw a threaded metal stud into each of the
holes at the four corners of the louver.
Air
Baffles
Widt
h
SCREWS
FOAM
GASKET
Outside
Edge
Drip )
ate plied
s
n
de
Sup
Con Field
(
l
e
Pan
DETAIL A
NUT
Architectural Louver Installation (PXAA)
Wall Sleeve
2"
FOAM
GASKET
Seal condensate drip pan
to wall sleeve with sealant
on all (4) bottom corners.
IMPORTANT NOTE:
The silicone bead MUST extend up
the side of the two flanges to prevent
condensate from leaking.
2. From inside the building, grasp the louver
at the vertical supports and maneuver the
louver through the wall sleeve. Pull towards
you until the threaded studs are inserted into
the four holes of the wall sleeve.
CAUTION
Bodily injury can be caused by louvers
falling from a building during installation. It is
recommended that a safety line be attached
to the louver and an anchor point inside the
building during installation.
3. While holding the louver with one hand, start
washers and nuts on each of the four studs.
Tighten the nuts securely.
11
Accessories
HVAC Engineering Specifications
Digital Packaged Terminal Air Conditioners & Heat Pumps
New Construction Accessories
Cooling: 7600 – 15000 Btu
Heating: 6100 – 13300 Btu (Heat Pump)
6824 – 17060 Btu (Electric Heat)
Friedrich Models: PDE – Cooling with or without electric heat
PDH – Heat Pump with electric heat
All units shall be factory assembled, piped, wired and fully charged
with R-410A. All units shall be certified in accordance with ARI Standard 310 for air conditioners and ARI standard 380 for heat pumps.
Units shall be UL listed and carry a UL label. All units shall be factory
run-tested to check operation and be Friedrich or equivalent.
The basic unit shall not exceed 16” high x 42” wide. Overall depth of
the unit from the rear of the Friedrich wall sleeve to the front of the
decorative front cover shall not exceed 21 ¼”. The unit shall be designed so that room intrusion may be as little as 7 ½”. Installations in
walls deeper than 13 ¼” may be accomplished with the use of a deep
wall sleeve (PDXWSEXT). Unit shall draw in ambient air through both
sides of an outdoor architectural louver or grille measuring 42” wide
x 16” high and shall exhaust air out middle portion of the louver. The
architectural louver and wall sleeve shall be designed so that the
louver may be installed from the inside of the building.
REFRIGERATION SYSTEM – The refrigeration system shall be hermetically sealed and consist of a rotary compressor that is externally
mounted on vibration isolators no smaller than 1 3/8” dia. x 1 ½” high;
condenser and evaporator coils constructed of copper tubes and
aluminum plate fins; and capillaries as expansion devices. Unit shall
have a fan slinger ring to increase efficiency and condensate disposal
and have a drain pan capable of retaining 1 ½ gallons of condensate.
A tertiary condensate removal system shall also be incorporated for
back up and shall overflow through the wall sleeve and to the outside
of the building as a safeguard against damage to the interior room.
INDOOR AIR HANDLING SECTION – The indoor air handling section
shall consist of a tangential blower wheel direct driven by a totally enclosed motor. The air handling system shall be designed to minimize
airflow noise and provide smooth and consistent airflow. The indoor
fan must have three fan speeds that may be selected by the user.
The indoor discharge grille shall be designed to maximize airflow
throughout the room. The grille shall be reversible to allow a change
in the airflow directions. The grille openings shall be sized to prevent
personal injury or damage to the unit.
The front cover shall incorporate dual air filters conveniently mounted
in the front of the unit. The filters must be accessible without the
removal of the front cover. The filters shall be made of anti-microbial
material to prevent mold and bacterial growth. The filters shall be
washable and reusable by cleaning with water or by vacuuming.
The chassis shall have a built-in damper capable of providing at least
75 CFM of fresh air into the conditioned area. A fine mesh screen shall
filter the incoming fresh air. There must be a provision for locking
the damper closed to ensure a proper seal.
OUTDOOR AIR HANDLING SECTION – The outdoor air section shall
consist of a single injection molded fan shroud that incorporates the
outdoor motor mount into a single piece for ease of service and assembly. The outdoor motor shall be totally enclosed, ball-bearing,
permanently lubricated and directly drive the outdoor fan/slinger ring.
CONTROLS – Covered controls shall be accessible in a compartment
at least 7½” wide with the controls no deeper than 1 ¼” in the opening
to facilitate easy operation of the unit.
The unit controls shall feature a soft blue LED readout that can
display either room temperature or setpoint temperature. The unit
shall receive input from the digital control panel through push buttons labeled: ‘Cool’, ‘Heat’, ‘High Fan’, ‘Med Fan’, ‘Low Fan’,  ’, ‘’
and ‘Power’. When ‘Off’, the unit may be put directly into cooling or
heating mode by pressing the ‘Cool’ or ‘Heat’ button.
12
PDXWSA
The unit must have the following energy saving and convenience
features built-in:
• Quiet start/stop fan delay
• Fan cycle control for cooling and heating independently
• Room freeze protection
• Random compressor restart
• Electronic temperature limiting
The PTAC must also offer the ability to be controlled by a remote
wall-mounted thermostat without additional accessories. Low voltage inputs will include: C (common), R (24V power), Y (cooling), GL
(fan low), GH (fan high), W (heat) and O (reversing valve on PDH heat
pumps only).
PTAC models shall use a single stage cool / single stage heat thermostat. PTHP models shall use a single stage cool / two-stage heat
thermostat. An accessory thermostat must be available from the
manufacturer, RT6 or equivalent. The RT6 thermostat will provide
temperature setpoint, mode selection from cool, heat and fan modes.
The thermostat must also allow the selection of fan speed between
high and low speed.
Other controls accessible without removal of the chassis shall include
fan cycle switch, fresh air vent control and emergency heat override
switch (heat pump only).
PDXWSEXT18
DEEP WALL SLEEVE For walls up to 17 1/2" deep.
PDXWSEXT24
DEEP WALL SLEEVE For walls up to 23 1/2" deep.
PDXWSEXT
WARRANTY – The warranty is two years on all parts and labor and 5
years on the sealed system, parts and labor, including compressor,
indoor and outdoor coils and refrigerant tubing.
CUSTOM DEEP WALL SLEEVE One piece extended wall sleeve for walls
from 13 1/4" to 25 1/2" deep are available by special order.
PXSE
SLEEVE EXTENSION RETROFIT KIT Galvanized zinc coated steel, 2.4"
sleeve extension attached to the room side of the sleeve to allow for the
installation of a PD-Series Friedrich PTAC in a T-Series sleeve.
PXGA
GRILLE Standard, stamped aluminium, anodized to resist chalking and
oxidation.
PXAA
PXBG
PXSC
ARCHITECTURAL GRILLES Consist of heavy-gauge 6063-T5
aluminum alloy: 42" W x 16" H x 1.125" D
PXGA
PXAA – Clear, extruded aluminum
PXBG – Beige acrylic enamel
PXSC – Also available in custom colors.
PXAA
PXDR10
CONDENSATE DRAIN KIT Attaches to the bottom of the wall sleeve for
internal draining of condensate or to the rear wall sleeve flange for external draining. Recommended on all units to remove excess condensate. Packaged in quantities of ten.
POWER CORDS
PXPC23000
PXPC23015
PXPC23020
PXPC23030
PXPC26515
PXPC26520
PXPC26530
The front panel shall attach firmly to the chassis by two hidden spring
clips. As an option the cover may be attached by two screws to prevent
tampering. The front panel will feature a contoured discharge with
no sharp corners.
CORROSION PROTECTION – The unit shall have corrosion-resistant
fans, fan shroud and drain pan for corrosion protection and to prevent rust on the side of the building below the outdoor louver. The
unit shall feature corrosion resistant materials and finishes to help
prevent deterioration. The outdoor coil shall have Diamonblue corrosion protection consisting of hydrophilic coated fins to prolong the
life of the coil in all applications including seacoast environments. All
outdoor coils shall also have stainless steel endplates to eliminate
rusting of the endplates.
PDXWS
Deep wall sleeve PDXWSEXT18 shown with weather panel
ELECTRICAL CONNECTION – All PTAC/PTHP units shall come from
the factory with a power cord installed. All 230/208V power cords shall
feature a leakage current detection device on the plug head. All units
shall feature a 6-pin connector for removal of the power cord. The
power cord shall be interchangeable to allow changes to the heater
output based on the property/electrical requirements.
GENERAL CONSTRUCTION – The wall sleeve shall be constructed
of 18-gauge Galvanized zinc-coated steel. It shall be prepared by
a process where it is zinc phosphate pretreated and sealed with a
chromate rinse, then powder coated with a polyester finish and oven
cured for durability. The sleeve shall be shipped with a protective
weatherboard and a structural center support, and be insulated for
sound absorption and thermal efficiency. The grille or louver shall
be shipped separately and made from stamped or extruded anodized
aluminum. All louvers shall be in the horizontal plane.
WALL SLEEVE Galvanized zinc coated steel is prepared in an 11-step
process, then powder coated with a polyester finish and cured in an
oven for exceptional durability. The wall sleeve is insulated for sound
absorption and thermal efficiency, 16" High x 42" Wide x 13 3/4" Deep.
LCDI 230V 15A Cord - 00 kW (for use PDE models only)
LCDI 230V 15A Cord - 2.0 kW
LCDI 230V 20A Cord - 3.0 kW
LCDI 230V 30A Cord - 5.0 kW
Non-LCDI 265V 15A Cord - 2.0 kW
Non-LCDI 265V 20A Cord - 3.0 kW
Non-LCDI 265V 30A Cord - 5.0 kW
Plug Face
6-15
6-15
6-20
6-30
7-15
7-20
7-30
PXCJA
CONDUIT KIT WITH JUNCTION BOX Hard wire conduit kit with junction box for 208/230V and 265 V units (subbase not required).
Kit includes a means of quick disconnect for easy removal of the
chassis. *Required for 265V installations.
PXFTA
REPLACEMENT FILTER PACK These are original equipment return air
filters. They are reusable and can be cleaned by vacuuming, washing,
or blowing out, and are sold in convenient ten-packs. (Two filters per
chassis).
13
Accessories
New Construction Accessories
PDXDAA
LATERAL DUCT ADAPTER Attaches to the Friedrich PTAC/PTHP unit
to direct up to 35% of the total airflow to a second room. The unitmounted duct plenum features a front-mounted aluminum grille that
has two positions to provide the most optimal air direction. The air may
be directed to either the left or the right of the unit through the supplied
3.5 H" x 7 W" x 47" L plenum. Plenum may be cut to length by the installer. Kit includes duct plenum, front grille, 47" duct extension, duct
discharge grille, duct end cap and all necessary mounting hardware.
PDXDEA
LATERAL DUCT EXTENSION Additional 3.5 H" x 7" W x 47" L plenum
for use with the LATERAL DUCT ADAPTER. A maximum of 3 duct
extensions total may be used. Note: Ducted airflow is reduced as duct
length is increased.
PXSBA
DECORATIVE SUBBASE Provides unit support for walls less than six
inches thick. Includes leveling legs, side filler panels and mounting brackets for electrical accessories. Accepts circuit breaker,
power disconnect switch, or conduit kit.
PXSB
ELECTRICAL SUBBASE Provides unit support for walls less than six
inches thick. Includes leveling legs, side filler panels, mounting brackets, a plug-in receptacle and field-wiring access. The subbase
also includes electrical knockouts for a power disconnect switch or
circuit breaker.
PXSB23020
PXSB23030
PXSB26515
PXSB26520
PXSB26530
14
Electrical Subbase - 230V 20A
Electrical Subbase - 230V 30A
Electrical Subbase - 265V 15A
Electrical Subbase - 265V 20A
Electrical Subbase - 265V 30A
RT6
DIGITAL REMOTE THERMOSTAT Single stage cool, single stage heat
for PDE models or single stage cool, dual stage heat for PDH model
thermostat features high/low fan speed switch. Thermostat is hard
wired and can be battery powered or unit powered. Features backlit display and multiple configuration modes. For use on PD-series
Friedrich PTACs and Vert-I-Paks.
WRT1
WIRELESS DIGITAL REMOTE THERMOSTAT Single stage cool, single
stage heat for PDE models or single stage cool, dual stage heat for
PDH model thermostat features high/low fan speed switch. Thermostat is wireless and is battery powered. Features backlit display and
multiple configuration modes. For use on PD-series Friedrich PTACs
and Vert-I-Paks.
PDXRTA
REMOTE THERMOSTAT ESCUTCHEON KIT This kit contains ten escutcheons that can be placed over the factory control buttons when a
remote wall mounted thermostat is used. The escutcheon directs the
guest to the wall thermostat for operation and retains the LED window
to display error codes and diagnostic information.
EMRT1
Wired thermostat with occupancy sensor.
EMWRT1
THIS PAGE INTENTIONALLY LEFT BLANK.
Wireless thermostat with occupancy sensor.
EMOCT
Online connection kit.
EMRAF
Remote access fee.
15
Friedrich Air Conditioning Company
10001 Reunion Place, Suite 500
San Antonio, TX 78216
800.541.6645
www.friedrich.com
PD-SERIES
PACKAGED TERMINAL AIR CONDITIONERS
LIMITED WARRANTY
SAVE THIS CERTIFICATE. It gives you specific rights. You may also have other rights which may vary from state to state and province to
province.
In the event that your unit needs servicing, contact your nearest authorized service center. If you do not know the nearest service center,
ask the company that installed your unit or contact us - see address and telephone number above. To obtain service and/or warranty parts
replacement, you must notify an authorized FRIEDRICH Air Conditioning Co. service center, distributor, dealer, or contractor of any defect
within the applicable warranty period.
When requesting service: please have the model and serial number from your unit readily available.
Unless specified otherwise herein, the following applies:
FRIEDRICH PACKAGED TERMINAL AIR CONDITIONERS AND HEAT PUMPS
LIMITED WARRANTY - TWO YEAR (Twenty-four (24) months from the date of installation). Any part found to be defective in the
material or workmanship will be repaired or replaced free of charge by our authorized service center during the normal working hours; and
LIMITED WARRANTY - THIRD THROUGH FIFTH YEAR (Sixty (60) months from the date of installation). ON THE SEALED
REFRIGERATION SYSTEM. Any part of the sealed refrigeration system that is defective in material or workmanship will be repaired or
replaced free of charge (excluding freight charges) by our authorized service center during normal working hours. The sealed refrigeration
system consists of the compressor, metering device, evaporator, condenser, reversing valve, check valve, and the interconnecting tubing.
These warranties apply only while the unit remains at the original site and only to units installed inside the continental United
States, Alaska, Hawaii, Puerto Rico, Mexico and Canada. The warranty applies only if the unit is installed and operated in
accordance with the printed instructions and in compliance with applicable local installation and building codes and good trade
practices. For international warranty information, contact the Friedrich Air Conditioning Company - International Division.
Any defective part to be replaced must be made available to FRIEDRICH in exchange for the replacement part. Reasonable proof must be
presented to establish the date of install, otherwise the beginning date of this certificate will be considered to be our shipment date plus sixty
days. Replacement parts can be new or remanufactured. Replacement parts and labor are only warranted for any unused portion of the
unit’s warranty.
We will not be responsible for and the user will pay for:
1. Service calls to:
A) Instruct on unit operation. B) Replace house fuses or correct house wiring. C) Clean or replace air filters. D) Remove the unit
from its installed location when not accessible for service required. E) Correct improper installations.
2. Parts or labor provided by anyone other than an authorized service center.
3. Damage caused by:
A) Accident, abuse, negligence, misuse, riot, fire, flood, or acts of God. B) Operating the unit where there is a corrosive atmosphere
containing chlorine, fluorine, or any damaging chemicals (other than in a normal residential environment). C) Unauthorized
alteration or repair of the unit, which in turn affects its stability or performance. D) Failing to provide proper maintenance and
service. E) Using an incorrect power source. F) Faulty installation or application of the unit.
We shall not be liable for any incidental, consequential, or special damages or expenses in connection with any use or failure of
this unit. We have not made and do not make any representation or warranty of fitness for a particular use or purpose and there
is no implied condition of fitness for a particular use or purpose. We make no expressed warranties except as stated in this
certificate. No one is authorized to change this certificate or to create for us any other obligation or liability in connection with
this unit. Any implied warranties shall last for one year after the original purchase date. Some states and provinces do not allow
limitations on how long an implied warranty or condition lasts, so the above limitations or exclusions may not apply to you. The provisions of
this warranty are in addition to and not a modification of or subtraction from the statutory warranties and other rights and remedies provided
by law.
Performance of Friedrich’s Warranty obligation is limited to one of the following methods:
1. Repair of the unit
2. A refund to the customer for the prorated value of the unit based upon the remaining warranty period of the unit.
3. Providing a replacement unit of equal value
The method of fulfillment of the warranty obligation is at the sole discretion of Friedrich Air Conditioning.
In case of any questions regarding the provisions of this warranty, the English version will govern.
PTAC_Product_Profile_2014
(9-12)