Digital Packaged Terminal Air Conditioners & Heat Pumps PDXWS PDXWSEXT PXGA PXAA PDE Series PDH Series 250 V Receptacles and Fuse Types PDE 230V - Extended Cooling Performance PDH 230V - Extended Cooling Performance Extended Heating Performance PDE 265V - Extended Cooling Performance PDH 265V - Extended Cooling Performance Extended Heating Performance Electric Heat Data Electric Heat Data Electric Heat Data Electric Heat Data FRP030 High Heat DIP SWITCH Powe Med r Cool Low Fan Speed Fan Mode Temp eratur e UP 1 2 3 4 5 6 7 DOWN LOCATION OF DIP SWITCHES ON UNIT Freeze guard Setpoint Limit 2 Setpoint Limit 1 Fan CON/CYC for cooling Fan CON/CYC for heating Wall Thermostat enable Electric heat only (for Heat Pumps) FRP028 Low Load Conditions High Load Conditions Low Load Conditions Low Air Flow Across Indoor Coil High Air Flow Across Indoor Coil Refrigerant System Restriction Refrigerant System Restriction Reversing Valve not Fully Seated Undercharged Overcharged Moisture in System Defective Compressor High Load Conditions Low Air Flow Across Outdoor Coil Reversing Valve not Fully Seated Overcharged Non-Condensables (air) Undercharged System Defective Compressor Low Air Flow Across Outdoor Coil Outdoor Ambient Too High for Operation in Heating Refrigerant System Restriction Outdoor Ambient Too High For Operation In Heating Low Air Flow Across Indoor Coil Refrigerant System Restriction Reversing Valve not Fully Seated Reversing Valve not Fully Seated Undercharged Overcharged Undercharged Overcharged Defective Compressor Non-Condensables (air) in System Moisture in System Defective Compressor RT6 To Install Thermostat Electronic Thermostat Installation, Operation & Application Guide Parts Diagram Wiring Diagrams Terminal Designator Descriptions Icon Descriptions RT6 Output Chart Specifications Configuration 1ST Cool 1ST Heat 2ND Heat Important Safety Information Configuration Mode Package Contents/Tools Required To Remove Existing Thermostat Configuration Mode Settings Operating Modes OFF Mode Heat Mode Cool Mode Set Point Adjustment Heat Set Point Cool Set Point Testing the Thermostat Heat Test Cool Test Fan Test Mode of Operation Troubleshooting Button Functions Symptom Remedy Resistance Table for Air Indoor Temperature Sensor Temp. F Resistance k Temp. F Resistance k Temp. F Resistance k Temp. F Resistance k -19 -18 -17 -16 -15 -14 -13 -12 -11 -10 -9 -8 -7 -6 -5 -4 -3 -2 -1 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 138.100 128.600 121.600 115.000 108.700 102.900 97.400 92.220 87.350 82.750 78.430 74.350 70.500 66.880 63.460 60.230 57.180 54.310 51.590 49.020 46.600 44.310 42.140 40.090 38.150 36.320 34.580 32.940 31.380 29.900 28.510 27.180 25.920 24.730 23.600 22.530 21.510 20.540 19.630 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 18.750 17.930 17.140 16.390 15.680 15.000 14.360 13.740 13.160 12.600 12.070 11.570 11.090 10.630 10.200 9.779 9.382 9.003 8.642 8.297 7.967 7.653 7.352 7.065 6.791 6.529 6.278 6.038 5.809 5.589 5.379 5.197 4.986 4.802 4.625 4.456 4.294 4.139 3.990 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 3.848 3.711 3.579 3.454 3.333 3.217 3.105 2.998 2.896 2.797 2.702 2.611 2.523 2.439 2.358 2.280 2.206 2.133 2.064 1.997 1.933 1.871 1.811 1.754 1.699 1.645 1.594 1.544 1.497 1.451 1.408 1.363 1.322 1.282 1.244 1.207 1.171 1.136 1.103 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 1.071 1.039 1.009 0.980 0.952 0.925 0.898 0.873 0.848 0.825 0.802 0.779 0.758 0.737 0.717 0.697 0.678 0.660 0.642 0.625 0.608 0.592 0.577 0.561 0.547 0.532 0.519 0.505 0.492 0.480 0.467 0.456 0.444 0.433 0.422 0.412 0.401 0.391 0.382 Resistance Table for Frost Protection Indoor and Outdoor Temperature Sensors Temp. Resistance F k -19 -18 -17 -16 -15 -14 -13 -12 -11 -10 -9 -8 -7 -6 -5 -4 -3 -2 -1 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 181.400 171.400 162.100 153.300 145.000 137.200 129.900 123.000 116.500 110.300 104.600 99.130 94.000 89.170 84.610 80.310 76.240 72.410 68.790 65.370 62.130 59.080 56.190 53.460 50.870 48.420 46.110 43.920 41.840 39.870 38.010 36.240 34.570 32.980 31.470 30.040 28.680 27.390 26.170 Temp. Resistance F k 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 25.010 23.900 22.850 21.850 20.900 20.000 19.140 18.130 17.550 16.800 16.100 15.430 14.790 14.180 13.590 13.040 12.510 12.000 11.520 11.060 10.620 10.200 9.803 9.420 9.054 8.705 8.370 8.051 7.745 7.453 7.173 6.905 6.648 6.403 6.167 5.942 5.726 5.519 5.320 Temp. Resistance F k 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 5.130 4.948 4.773 4.605 4.443 4.289 4.140 3.998 3.861 3.729 3.603 3.481 3.364 3.252 3.144 3.040 2.940 2.844 2.752 2.663 2.577 2.495 2.415 2.339 2.265 2.194 2.125 2.059 1.996 1.934 1.875 1.818 1.736 1.710 1.658 1.609 1.561 1.515 1.470 Temp. Resistance F k 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 1.427 1.386 1.346 1.307 1.269 1.233 1.198 1.164 1.131 1.099 1.069 1.039 1.010 0.983 0.956 0.930 0.904 0.880 0.856 0.833 0.811 0.770 0.769 0.746 0.729 0.710 0.692 0.674 0.658 0.640 0.623 0.607 0.592 0.577 0.563 0.549 0.535 0.521 0.509
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement