Friedrich | SH20M30B | Submittal | Friedrich SH20M30B Submittal

Friedrich SH20M30B Submittal
Hazardgard®
Hazardous Location Room Air Conditioners
PURCHASER
P.O. #
PROJECT
LOCATION
ENGINEER
ARCHITECT
SUBMITTED BY
FOR APPROVAL
ITEM
PLAN DESIGNATION
UL LISTED
QUANTITY
DATE
COOLING BTU/H
Features
for CLASS 1, DIV 2,
GROUPS A, B, C and D.
• Direct wire connection
• Utilizes direct-wired, 15-amp circuit
with time-delay fuse
CERTIFIED
in accordance with
ISA 12.12.01 and NFPA 70
(NATIONAL ELECTRIC CODE),
ANSI/UL 484 Room Air Conditioners
• Hermetically sealed reciprocating
compressor
• 22 gauge steel cabinet
• Larger, commercial grade fan motor
with hermetically sealed overload for
arc-free operation
• Permanent split capacitor and totally
enclosed fan motor
KSA REGISTERED
and TESTED in accordance with
SASO 2681*
• Enclosed fan motor has hermetically
sealed overload for arc-free operation
FOR REFERENCE
VOLTAGE
FRIEDRICH MODEL
Coils coated for corrosion
resistance
MODEL SH24N20
• ElectroFin® 5-stage, immersion ecoat
process on 100% of metallic surfaces on the
outdoor coil provides outstanding corrosion
resistance protection in coastal or corrosive
environments.
ELECTROFIN BENEFITS:
• Excellent adhesion characteristics
• Less than 1% thermal degradation
• Outstanding chemical resistance
• Passed 6048 hrs.ASTM B-117 Salt Spray
ELECTROFIN MEETS THE FOLLOWING:
• MIL-C-46168 Chemical Agent Resistance
-DS2, HCI Gas
• Hermetically sealed refrigeration
system
• CID A-A-52474A (GSA)
• Environmentally sealed on/off switch
and gold plated contacts in thermostat
for corrosion resistance
• MIL-P-53084 (ME)-TACOM Approval
• Solid-state relays for compressor and
fan operation
• Hot gas bypass allows the air
conditioner to operate at low ambient
conditions without freezing
• MIL-STD 810F, Method 509.4 (Sand and Dust)
• MIL-DTL-12468 Decontamination Agent (STB)
• DPG (Douglas Proving Grounds) Soil & Water
Exposure Tests
• GM9540P-97 Accelerated Corrosion Test (120
cycles)
• ASTM B117-G85 Modified Salt Spray (Fog)
Testing-2,000 hours
• ASTM B117 Salt Spray (tested by ARL for
Lockheed Martin)
MODELS SH15M30A, SH20M30B,
SH20M30SA, SH20M50A
*Only for model SH20M30B
LISTED
ROOM AIR CONDITIONERS
183H
Hazardgard_Submital_2018
• Diamonblue Advanced Corrosion
Protection™ on the outdoor coil
protects the coil against deterioration
and extends the life of the unit
especially in coastal or corrosive
environments.
Installation: Wall Cut Out & Chassis Dimensions
Hazardgard Model: SH15M30A
C
25 15/16" (660mm)
26 3/16" (662mm)
2
16 3/16" (408mm)
SUPPLY
15 15/16" (405mm)
EW
SUPPLY
27 3/8"
Hazardgard
RETURN
D
INDOOR, FACE VIEW
BUILDING WALL CUT OUT
FOR UNIT/SLEEVE
B
25 15/16" (660mm)
CONDENSER AIR OUTLET
AT REAR OF UNIT
C
m)
SUPPLY
1
CONDENSER AIR INLET
ON BOTH SIDES OF UNIT
A
27 3/8" (695mm)
BUILDING WALL
4
3
TOP VIEW
B
Installation: Wall Cut Out & Chassis Dimensions
Hazardgard Model: SH20M30B / SH20M30SA / SH20M50A / SH24N20
C
25 15/16" (660mm)
26 3/16" (662mm)
2
1
18 3/16" (460mm)
17 15/16" (456mm)
EW
27 3/8" (
Hazardgard
RETURN
D
INDOOR, FACE VIEW
BUILDING WALL CUT OUT
FOR UNIT/SLEEVE
B
25 15/16" (660mm)
CONDENSER AIR OUTLET
AT REAR OF UNIT
C
m)
UPPLY
SUPPLY
SUPPLY
CONDENSER AIR INLET
ON BOTH SIDES OF UNIT
A
27 3/8" (695mm)
BUILDING WALL
4
3
TOP VIEW
B
SPECIFICATIONS
Electrical Characteristics
Cooling Capacity
Model
Btu/Hr.
Volts
Rated
Cooling
Cooling
Circuit Rating Breaker or
T - D Fuse
Amps
Watts
Volts - Amps
Energy
Efficiency
Ratio
Moisture
Removal
Air
Circulation
EER
Pints/ Hr
CFM
Refrigerant
60 HERTZ
SH15M30A
14500/14000
230/208
6.9/7.5
1495/1443
250V-15
9.7/9.7
4.0
375
R-410A
SH20M30B
19000/19000
230/208
8.5/9.4
1965/1970
250V-15 (230V) / 250V-20 (208V)
9.7/9.6
5.5
375
R-410A
SH20M30SA
19000/19000
230/208
8.5/9.4
1965/1970
250V-15 (230V) / 250V-20 (208V)
9.7/9.6
5.5
375
R-410A
SH24N20
24000/23700
230/208
12.6/13.5
2727/2788
250V-30
8.8/8.5
8.0/7.5
385
R-410A
50 HERTZ
SH20M50A
19500/19100
240/220
9.8/10.3
2167/2156
250V-15
9.0/9.0
5.6/5.5
425
R-410A
SH24N20
21000/20500
240/220
15.0/13.2
2600/2412
250V-30
8.1/8.5
7.0/7.0
360
R-410A
INSTALLATION INFORMATION
Window Width
Inches
Dimensions
Inches
Depth with Depth J Box
Front
to Louvers
Model
Minimum
Extension
Into Room
Minimum
Extension
Outside
In-Wall Installation
Finished Hole Inches
Weight
Lbs.
Height
Width
)A(
Min.
Max.
Height
Width
Max. Depth
SH15M30A
15 15/16”
25 15/16”
27 3/8”
6”
3 1/16”
16 15/16”
27 7/8”
42”
16 3/16”
26 3/16”
6”
140
167
SH20M30B
17 15/16”
25 15/16”
27 3/8”
6”
3 1/16”
16 15/16”
27 7/8”
42”
18 3/16”
26 3/16”
6”
166
170
SH20M30SA
17 15/16”
25 15/16”
27 3/8”
6”
3 1/16”
16 15/16”
27 7/8”
42”
18 3/16”
26 3/16”
6”
166
170
SH20M50A
17 15/16”
25 15/16”
27 3/8”
6”
3 1/16”
16 15/16”
27 7/8”
42”
18 3/16”
26 3/16”
6”
171
175
SH24N20
17 15/16”
25 15/16”
27 3/8”
6”
3 1/16”
16 15/16”
27 7/8”
42”
18 3/16”
26 3/16”
6”
180
185
Net Shipping
Due to continuing engineering research and technology, specifications are supbject to change wihtout notice.
U.S. MAXIMUM outdoor ambient operating temperature is 130ºF. (55ºC) MAXIMUM TEMPERATURE RATING FOR CLASS 1,
DIVISION 2, GROUPS A, B, C, D.
Capacity and efficiency values at each climate conditions are available upon request.
NOTE: Hazardgard unit must be hard-wired.
Manufactured under Design Patent DES 368, 306 decorative front; Utility Patent 5, 662, 058.
T4 temperature classification means unit surface temperatures will not
rise above 135° C/275° F. Operates at low ambient conditions without
freezing at outdoor ambient temperatures as low as 7° C/45° F.
Sleeve Dimensions Drawing
)A(
Tolerates higher outdoor temperatures up to 55° C /130° F.
Max.
Wall
Depth
Equipment is certified in accordance with ISA 12.12.01 and NFPA 70-10
(National Electric Code)
ARTICLE 501
ARTICLE 505
Class I, Div. 2, Group A and Group B
Class I, Zone 2, Group IIC
Class I, Div. 2, Group B
Class I, Zone 2, Group IIB
plus hydrogen, or “+H2”
Class I, Div. 2, Group C
Class I, Zone 2, Group IIB
Class I, Div. 2, Group D
Class I, Zone 2, Group IIA
Junction
Box
Front
SIDE VIEW
LISTED
ROOM AIR CONDITIONERS
183H
Hazardgard_Submital_2018
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising