Friedrich | SH24N20 | Submittal | Friedrich SH24N20 Submittal

Friedrich SH24N20 Submittal
Hazardgard®
Hazardous Location Room Air Conditioners
PURCHASER
P.O. #
PROJECT
LOCATION
ENGINEER
ARCHITECT
SUBMITTED BY
FOR APPROVAL
ITEM
PLAN DESIGNATION
UL LISTED
for CLASS 1, DIV 2,
GROUPS A, B, C and D.
CERTIFIED
in accordance with
ISA 12.12.01 and NFPA 70
(NATIONAL ELECTRIC CODE),
ANSI/UL 484 Room Air Conditioners
KSA REGISTERED
and TESTED in accordance with
SASO 2681
QUANTITY
DATE
COOLING BTU/H
Features
• Direct wire connection
• Utilizes direct-wired, 15-amp circuit
with time-delay fuse
• Hermetically sealed reciprocating
compressor
• 22 gauge steel cabinet
• Larger, commercial grade fan motor
with hermetically sealed overload for
arc-free operation
• Permanent split capacitor and totally
enclosed fan motor
• Enclosed fan motor has hermetically
sealed overload for arc-free operation
FOR REFERENCE
VOLTAGE
FRIEDRICH MODEL
Coils coated for corrosion
resistance
MODEL SH24M20
• ElectroFin® 5-stage, immersion ecoat
process on 100% of metallic surfaces on the
outdoor coil provides outstanding corrosion
resistance protection in coastal or corrosive
environments.
ELECTROFIN BENEFITS:
• Excellent adhesion characteristics
• Less than 1% thermal degradation
• Outstanding chemical resistance
• Passed 6048 hrs.ASTM B-117 Salt Spray
ELECTROFIN MEETS THE FOLLOWING:
• MIL-C-46168 Chemical Agent Resistance
-DS2, HCI Gas
• Hermetically sealed refrigeration
system
• CID A-A-52474A (GSA)
• Environmentally sealed on/off switch
and gold plated contacts in thermostat
for corrosion resistance
• MIL-P-53084 (ME)-TACOM Approval
• Solid-state relays for compressor and
fan operation
• Hot gas bypass allows the air
conditioner to operate at low ambient
conditions without freezing
• MIL-STD 810F, Method 509.4 (Sand and Dust)
• MIL-DTL-12468 Decontamination Agent (STB)
• DPG (Douglas Proving Grounds) Soil & Water
Exposure Tests
• GM9540P-97 Accelerated Corrosion Test (120
cycles)
• ASTM B117-G85 Modified Salt Spray (Fog)
Testing-2,000 hours
• ASTM B117 Salt Spray (tested by ARL for
Lockheed Martin)
MODELS SH15M30A, SH20M30A,
SH20M50A
• Diamonblue Advanced Corrosion
Protection™ on the outdoor coil
protects the coil against deterioration
and extends the life of the unit
especially in coastal or corrosive
environments.
Hazardgard_Submital_2015
Specifications
Electrical Characteristics
Cooling Capacity
Model
Btu/Hr.
Volts Rated
Cooling
Cooling
Circuit Rating
Breaker or
T - D Fuse
Amps
Watts
Volts - Amps
Energy
Efficiency
Ratio
Moisture
Removal
Air Circulation
EER
Pints/ HR
CFM
Refrigerant
60 HERTZ
SH15M30A
14500/14000
230/208
6.9/7.5
1495/1443
250V-15
9.7/9.7
4.0
375
R-410A
SH20M30B
19000/19000
230/208
8.5/9.4
1965/1970
250V-15 (230V)
9.7/9.6
5.5
375
R-410A
SH24N20
24000/23700
230/208
12.6/13.5
2727/2788
8.8/8.5
8.0/7.5
385
R-401A
250V-20 (208V)
250V-30
50 HERTZ
SH20N50
19500/19100
240/220
9.8/10.3
2167/2156
250V-15
9.0/9.0
5.6/5.5
425
R-410A
SH24N20
21000/20500
240/220
15.0/13.2
2600/2412
250V-30
8.1/8.5
7.0/7.0
360
R-410A
Installation Information
Dimensions
INCHES
Model
Window Width
INCHES
Depth with Depth J Box
Front
to Louvers
)A(
Minimum Minimum
Extension Extension
Into Room Outside
In-Wall Installation
Finished Hole INCHES
Weight
Lbs.
Height
Width
Min.
Max.
Height
Width
Max. Depth
SH15M30BA
15 15/16”
25 15/16”
27 3/8”
6”
3 1/16”
16 15/16”
27 7/8”
42”
16 3/16”
26 3/16”
6”
140
167
SH20M30B
17 15/16”
25 15/16”
27 3/8”
6”
3 1/16”
16 15/16”
27 7/8”
42”
18 3/16”
26 3/16”
6”
166
170
SH20N50
17 15/16”
25 15/16”
27 3/8”
6”
3 1/16”
16 15/16”
27 7/8”
42”
18 3/16”
26 3/16”
6”
171
175
SH24N20
17 15/16”
25 15/16”
27 3/8”
6”
3 1/16”
16 15/16”
27 7/8”
42”
18 3/16”
26 3/16”
6”
180
185
Net Shipping
Due to continuing engineering research and technology, specifications are subject to change without notice. Manufactured under U.S. Design
Patent DES 368, 306 decorative front; Utility Patent 5, 622, 058. MAXIMUM outdoor ambient operating temperature is 130°F. (55°C) MAXIMUM
TEMPERATURE RATING FOR CLASS I, DIVISION 2, GROUPS A,B,C,D.
For global applications, Hazardgard cooling capacities are tested in a certified laboratory at moderate (T1*) and hot (T3*) climate conditions in
accordance with SASO (Saudi Arabian Standards Organization) Standard 2681. SASO Standard 2681 is adopted from ISO Standard 5151 for testing
and rating for performance of non-ducted air conditioners and heat pumps.
* Capacity and efficiency values at each climate conditions are available upon request.
T4 temperature classification means unit surface temperatures will not
rise above 135° C/275° F. Operates at low ambient conditions without
Sleeve Dimensions Drawing
freezing at outdoor ambient temperatures as low as 7° C/45° F.
)A(
Tolerates higher outdoor temperatures up to 55° C /130° F.
Max.
Wall
Depth
Equipment is certified in accordance with ISA 12.12.01 and NFPA 70-10
(National Electric Code)
ARTICLE 501
ARTICLE 505
Class I, Div. 2, Group A and Group B
Class I, Zone 2, Group IIC
Class I, Div. 2, Group B
Class I, Zone 2, Group IIB
plus hydrogen, or “+H2”
Class I, Div. 2, Group C
Class I, Zone 2, Group IIB
Class I, Div. 2, Group D
Class I, Zone 2, Group IIA
Junction
Box
Front
SIDE VIEW
Hazardgard_Submital_2015