Friedrich | MR24DY3JMA | Brochure | Friedrich MR24DY3JMA Brochure

Ductless Split Systems
Wall-mounted, Multizone Heat Pump
PURCHASER
P.O. #
PROJECT
LOCATION
ENGINEER
ARCHITECT
SUBMITTED BY
FOR APPROVAL
ITEM
PLAN DESIGNATION
QUANTITY
DATE
COOLING BTU/H
FOR REFERENCE
VOLTAGE
FRIEDRICH MODEL
Features
• Inverter technology (variable speed compressor)
• High efficiency for low operating cost
• DiamonGold Advanced Corrosion Protection™
• Self-cleaning indoor coil
• Cooling/Heating/Fan mode
MW07Y3JM, MW09Y3J, MW12Y3J
• Surge Cool/Heat
• Natural air flow
• 4-Way auto swing
• Ultra quiet operation
WIRELESS
REMOTE CONTROL
• Sleep mode
• Dry mode
• Auto restart
MW18Y3J
• Built-in low ambient standard, down to 14ºF (Cooling Mode)
• 24-hour on/off timer
• Built-in kick stand
• BLDC Motor
All Inverter line
PRECISION
PARTS
WARRANTY
COMPRESSOR
WARRANTY
MR24DY3JMA
Ductless_Wall-mounted_Multizone_Heat_Pump_Submittal_2018
MR36TQY3JMA
MR48DEY3JM
PERFORMANCE RATINGS
Multizone Wall-Mounted - Heat Pumps
INDOOR MODEL
SPECIFICATIONS
CAPACITY COOLING (RATED)
Btu
CAPACITY HEATING (RATED)
Btu
MOISTURE REMOVAL
Pts/h
AIRFLOW (QUIET, LOW, MED, HIGH)
CFM
SOUND RATING - INDOOR
dB-A
ELECTRICAL DATA
POWER SOURCE
V, Ø, Hz
REFRIGERATION SYSTEM
CONNECTIONS
LIQUID LINE O.D.
in
SUCTION LINE O.D.
in
DIMENSIONS & WEIGHT
WXHXD
in
NET WEIGHT
lbs
SHIPPING WEIGHT
lbs
7k
MW07Y3JM
9k
MW09Y3J
12k
MW12Y3J
18k
MW18Y3J
7,000
8,100
162/177/198
26/30/33
9,000
10,800
2.3
124/212/272/335
19 / 24 / 33 / 38
11,200
13,300
2.7
124/212/272/335
19 / 24 / 33 / 39
17,000
20,200
4.2
300/399/509/622
29 / 35 / 40 / 45
230/208-60-1
230/208-60-1
230/208-60-1
230/208-60-1
Flare
1/4
3/8
Flare
1/4
3/8
Flare
1/4
3/8
Flare
1/4
1/2
34-7/8 x11-1/4 x 8-1/4
20
26
PERFORMANCE RATINGS
Multi Outdoor
OUTDOOR MODEL
SPECIFICATIONS
POWER SOURCE
EST. YEARLY OPERATING COST
RUNNING CURRENT COOLING MIN.~RATED~MAX.
RUNNING CURRENT HEATING MIN.~RATED~MAX.
POWER INPUT COOLING MIN.~RATED~MAX.
POWER INPUT HEATING MIN.~RATED~MAX.
POWER AND COMMUNICATION CABLE
DIMENSIONS W X H X D
NET WEIGHT
SHIPPING WEIGHT
REFRIGERATION SYSTEM
REFRIGERANT
FACTORY PRECHARGE
REFRIGERANT CHARGE
LIQUID LINE O.D.
SUCTION LINE O.D.
MIN./MAX. LINE LENGTH (EACH)
MIN./MAX. LINE LENGTH (TOTAL)
MAX. HEIGHT DIFFERENCE
SOUND PRESSURE LEVEL COOLING
SOUND PRESSURE LEVEL HEATING
OPERATING RANGE COOLING (WIND BAFFLE)
OPERATING RANGE HEATING
MINIMUM AMPACITY
MAX. TD FUSE/BREAKER
$
A
A
W
W
No. x AWG
inch
lbs
lbs
9000 and 12000
BTU indoor units
18000 BTU indoor units
24000,30000 and 36000
BTU indoor units
24k
MR24DY3JMA
36k
MR36TQY3JMA
48k
MR48DEY3JM
208/230/60/1
122~125
1.7~6.4~9.0
1.8~7.8~11.2
390~1480~2070
420~1800~2580
4 X 14
34-1/4 x 25-3/4 x12-5/8
99
139
208/230/60/1
170~245
2.9~10.7~15.7
3.3~11.9~18.3
670~2460~3610
760~2740~4210
4 X 14
37-3/8 x 32-7/8 x 13
137
148
208/230/60/1
346~400
4.6~16.7~24.8
6.2~18.8~26.2
970~3840~5710
1420~4320~6020
4 X 14
37-3/8 × 54-5/16 × 13
214
236
R410A
63
74
1/4
3/8
10~82
75~246
49
51
51
14 (-4) ~ 118
-4 ~ 64
14.3
20
R410A
98
99
1/4
3/8
10~82
75~246
49
52
55
14 (-4) ~ 118
-4 ~ 64
17.9
25
R410A
155
Main= 16, Branch= 131
3/8
3/4
10~49*
30~475*
98*
54
56
14 (-4) -118
-4 ~ 64
27.3
40
ft
oz
in
in
ft
ft
ft
A
A
°F DB
°F WB
A
A
Optional Thermostat
Refrigeration line sets*
USED WITH
35-1/4 x11-1/4 x 8-1/4 35-1/4 x 11-1/4 x 8-1/4 40-5/8 x 12-7/8 x 9-5/8
23
23
31
27
27
40
Length Ft.
Liquid
Suction
Kit#
15’
1/4”
3/8”
T32150
35’
1/4”
3/8”
T32350
15’
1/4”
1/2”
T42150
35’
1/4”
1/2”
T42350
15’
3/8”
5/8”
T53150
35’
3/8”
5/8”
T53350
WIRED
CONTROLLER
DWC1
*Insulated line sets are available for all Friedrich split systems in 15
ft. and 35 ft. lengths. Each line set is equipped with flare nuts on both
ends. Both liquid and suction lines are insulated. Line sets can be
joined together with field supplied double male connectors. Each system
requires one line set for each indoor unit installed.
On multi-zone systems, line sets should be ordered based on individual
indoor unit capacities not total system capacity.
Your operating costs will depend on your utility rates and use. The estimated operating cost is based on a electricity cost of $ .115 per kWh. For
more information, visit www.ftc.gov/energy.
Due to continuing research in new energy-saving technology, specifications
are subject to change without notice.
Works with all Friedrich models.
Ductless_Wall-mounted_Multizone_Heat_Pump_Submittal_2018
DIMENSIONAL DRAWINGS
INDOOR UNIT / MW07Y3JM
Item No.
Part Name
1
Front panel
2
Display and signal receiver
3
Return air grille
4
Knockout hole
5
Installation Plate
Remark
For pipe and cable
Ductless_Wall-mounted_Multizone_Heat_Pump_Submittal_2018
Note
1. Unit should be installed in compliance with the installation manual
in the product box.
2. Unit should be grounded in accordance with the local regulations
or applicable national codes.
3. All electrical components and materials to be supplied on the site
must comply with local regulations or international codes.
4. Electrical characteristics chapter should be considered for electrical
work and design. Especially the capacity of power cable and circuit
breaker for outdoor units should be more than that of electrical
characteristics chapter.
DIMENSIONAL DRAWINGS
INDOOR UNITS / MW09Y3J, MW12Y3J
3
480(18 29/32)
412(16 1/4)
210(8 9/32)
885(34 27/32)
285(11 1/4)
Unit Outline
Ø65(2 9/16)
4
1
Left Rear
Piping 136(5 3/8)
178(7 1/32)
2
Ø65(2 9/16)
Place a level on raised tab
5
Installation Plate
Right Rear
123(4 27/32) Piping
(Unit : in)
245(9 21/32)
Unit: inch (mm)
Item No.
Part Name
1
Air discharge grille
2
Gas pipe connection
3
Liquid pipe connection
4
Power & transmission connection
5
Earth screw
6
Main service valve (Liquid)
7
Main service valve (Gas)
Remark
Note
1. Unit should be installed in compliance with the installation manual
in the product box.
2. Unit should be grounded in accordance with the local regulations
or applicable national codes.
3. All electrical components and materials to be supplied on the site
must comply with local regulations or international codes.
4. Electrical characteristics chapter should be considered for electrical
work and design. Especially the capacity of power cable and circuit
breaker for outdoor units should be more than that of electrical
characteristics chapter.
INDOOR UNITS / MW18Y3J
Unit: inch (mm)
Item No.
Part Name
1
Front Panel
2
Display & Signal Receiver
3
Air Suction Grille
4
Knockout Hole
5
Installation Plate
Remark
For pipe and cable
Ductless_Wall-mounted_Multizone_Heat_Pump_Submittal_2018
Note
1. The unit should be installed according to installation
manual which is in the product box.
2. The unit is powered from the outdoor unit. So power cable
should be connected with the outdoor unit.
DIMENSIONAL DRAWINGS
OUTDOOR UNITS / MR24DY3JMA
Item No.
Part Name
1
Air Discharge Grille
2
Gas Pipe Connection
3
Liquid Pipe Connection
4
Power and Transmission Connection
5
Main Service Valve (Gas)
6
Main Service Valve (Liquid)
Note
1. Unit should be installed in compliance with the installation
manual in the product box.
2. Unit should be grounded in accordance with the local
regulations or applicable national codes.
3. All electrical components and materials to be supplied from
the site must comply with the local regulations or international
codes.
4. Electric characteristics chapter should be considered for
electrical work and design. Especially, the power cable and
circuit breaker should be selected in accordance with that.
OUTDOOR UNITS / MR36TQY3JMA
Item No.
Part Name
1
Air discharge grille
2
Gas pipe connection
3
Liquid pipe connection
4
Main Service Valve (Liquid)
5
Main Service Valve (Gas)
Note
1. Unit should be installed in compliance with the installation
manual in the product box.
2. Unit should be grounded in accordance with the local
regulations or applicable national codes.
3. All electrical components and materials to be supplied on the
site must comply with the local regulations or international codes
4. Electrical characteristics chapter should be considered for
electrical work and design. Especially the capacity of power cable
and circuit breaker for outdoor unit should be more than that of
electrical characteristics chapter.
Ductless_Wall-mounted_Multizone_Heat_Pump_Submittal_2018
DIMENSIONAL DRAWINGS
OUTDOOR UNITS / MR48DEY3JM
Item No.
Part Name
1
Liquid pipe connection
2
Gas pipe connection
3
Air discharge grille
4
Power & transmission connection
Ductless_Wall-mounted_Multizone_Heat_Pump_Submittal_2017
Description
REFRIGERATION LINE SETS MINIMUM/MAXIMUM LENGTHS
MULTIZONE | 48,000 BTU
Multizone 48,000 BTU/h Eight Zone
Total piping length (Outdoor to Indoor ) (Tp)
System Pipe
Lengths
Min.
Outdoor to Branch box (A, B)
Elevations
≤476
(ft.)
10
(ft.)
≤180
(ft.)
≤295
Min.
(ft.)
10
Max.
Max.
Total branch piping length (Branch Box to indoor units) (A1-A3, B1-B4)
Branch box to Indoor units
(ft.)
(ft.)
≤49
If outdoor unit is above or below indoor unit (E1)
(ft.)
≤98
Between the farthest two indoor units (E3)
(ft.)
≤43
Between branch distribution unit and farthest connected indoor unit(s) (E2)
(ft.)
≤33
Between branch boxes (E4)
(ft.)
≤43
(Tp)
A
BB unit
A1
A2
E4
E1
E3
A3
B
BB unit
B1
E2
B2
B3
B4
SINGLE AND DUAL BB CONFIGURATIONS
BB unit
Branch Box D4PBB
Y-Branch (DYBK)
BB unit
Y - Branch DYBK
Ductless_Wall-mounted_Multizone_Heat_Pump_Submittal_2018