GE | AZ65H09DAD | Quick Specs | GE AZ65H09DAD Quick Specs

GE AZ65H09DAD Quick Specs
AZ65H09DAD
GE Zoneline® Heat Pump Unit with ICR, 230/208
Volt
Zoneline RAC Wall Installation
DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES)
ELECTRICAL WIRING
All wiring, including installation of receptacle, must
be made in accordance with local electrical codes
and ­regulations.
WALL CASE DIMENSIONS
RETROFIT KITS:
RAK40 – Deflector Kit to adapt chassis for use with
existing (non-GE) exterior louvered grilles.
DUCTED APPLICATIONS
AZ45 and AZ65 Series can be used with ductwork to heat
or cool more than one room. RAK6053 Duct Adaptor is
applied to the top of case over the air discharge. RAK601B
Duct Extension is applied to right or left of adaptor.
Locally fabricated ductwork may be added to extend to
maximum recommended straight distance of
15 feet in one direction.
ELECTRICAL CONNECTION
230/208 volt units may be plugged into a receptacle.
See Architects and Engineers Design Data Manual for
­electrical connection information including use of sub-base
for direct connected units. Installation must ­comply with
local electrical codes and regulations.
Power connection kits are required on all Zoneline chassis.
Inside
Outside
Room
Cabinet
MAXIMUM CORD EXTENSION
A
NOTE: Aluminum wiring may pose special problems –
consult a qualified electrician.
GRILLE OPTIONS
Stamped Aluminum Grille – RAG60
Exterior Architectural Louvers Durable Polycarbonate:
RAG61 (Beige)
RAG63 (Dark Brown)
RAG62 (Maple)
Extruded Aluminum Architectural Grille – RAG67
RAB71A = 16
RAB77A = 16-1/4
SIDE
VIEW
C
21
58
B
RAB71B WALL SLEEVE
Heavy-gauge galvanized steel, with
insulation.
A – 42", B – 13-3/4", C – 16"
Also available in 16" and 24" depths
RAB77B WALL SLEEVE
Molded SMC fiberglass-reinforced
polyester compound.
A – 42-1/8", B– 13-7/8", C – 16-1/4"
WALL OPENING DIMENSIONS
Add 1/4" to A and C dimensions
for all cut-outs.
RAB71B 16-1/4" Min. H x 42-1/4" Min. W
RAB77B 16-1/2" Min. H x 42-3/8" Min. W
AZ45/65 HEATER KW
230/208
LINE CORD (P), DIRECT (D) AND SUB-BASE CONNECTED UNITS
VOLT
7K/9K
12K/15K
RAK315P
RAK320P
RAK330P
RAK315P
RAK320P
Power
RAK315D
RAK320D
RAK330D
RAK315D
RAK320D
Connection Kit RAK204D15C RAK204D20C RAK204D30C RAK204D15C RAK204D20C
Total Watts
2410/1990
3420/2830
4830/3990
2430/2020
3450/2860
Heater Watts 2400/1960
3400/2780
4800/3930
2400/1960
3400/2780
Heater BTU
8100/6600
11600/9400
16300/13400
8100/6600
11600/9400
Total Amps
10.5/9.6
14.9/13.6
21.0/19.2
10.6/9.7
15.1/13.8
Min Circuit
15
20
30
15
20
Recommended 15 amp time- 20 amp time- 30 amp time- 15 amp time- 20 amp timeProtective
delay fuse or delay fuse or
delay fuse or
delay fuse or delay fuse or
Device
breaker
breaker
breaker
breaker
breaker
For more information, please visit our website at zoneline.com or call 888.231.2548.
RAK330P
RAK330D
RAK204D30C
4860/4020
4800/3930
16300/13400
21.2/19.3
30
30 amp timedelay fuse or
breaker
Specification Revised 7/16
AZ65H09DAD
GE Zoneline® Heat Pump Unit with ICR, 230/208 Volt
FEATURES AND BENEFITS
Cooling capacity - 9,600/9,500 BTU
Energy efficiency - 12.0/12.0 EER
Dehumidification - 2.6 pints/hour
Reverse heat cycle - 8,200/8,000 BTU
Heat pump efficiency - 3.6/3.6 COP
Indoor fan CFM (high/low) - 409/300
Fresh air vent CFM (fully open high fan) - 40
Quiet operation - Baked-on mastic sound barrier,
cross flow blower and two DC fan motors create less
noise to ensure comfort
Internal condensate removal - Minimizes condensate
draining from the unit during heat pump operation
Heat & Freeze Sentinels - Keeps the room from
overheating or freezing
Boost heat option - Provides supplemental resistance
heat in heat pump mode
Electronic temperature limiting - Prevents expensive
over-cooling or over-heating of the room
Electronic touch controls with LED display
R-410A refrigerant
SMC base pan
Specification Revised 7/16