Job Name/Location: Tag #: Date: For: PO No.: Architect: GC: Engr: Mech: File Resubmit Approval Other Rep: (Company) (Project Manager) LMDN096HV Multi F Ceiling Concealed Duct 9,000 Btu/h Indoor Unit Performance: Operating Range: Nominal Cooling Capacity (Btu/h) Nominal Heating Capacity (Btu/h) Cooling Nominal Test Conditions: Indoor: 80°F DB/67°F WB Outdoor: 95°F DB/75°F WB 9,000 10,400 Heating Nominal Test Conditions: 57‐77 Heating (°F DB) 59‐81 Unit Data: Indoor: 70°F DB/60°F WB Outdoor: 47°F DB/43°F WB Refrigerant Type Electrical: R410A EEV Refrigerant Control Power Supply (V¹/Hz/Ø) 208‐230/60/1 0.40 Rated Amps (A) Piping: Liquid Line (in, OD) 1/4 Vapor Line (in, OD) 3/8 1‐1/4, 1 Drain OD, ID (in) Thermistor Temperature Sensor Features: •2 Thermistor control •Auto opera on •Auto restart •Control lock func on Cooling (°F WB) Sound Pressure² H/M/L (±3 dB(A)) Included Accessories: •Simple Controller with Mode ‐ AKB72955816 Optional Accessories (sold separately LG Programmable Thermostat ‐ PREMTB10U0 Simple Controller with Mode (Black) ‐ PQRCVCL0Q Simple Controller with Mode (White) ‐ PQRCVCL0QW Simple Controller without Mode (Black) PQRCHCA0Q Simple Controller without Mode (White) ‐ PQRCHCA0QW AC Smart Premium ‐ PQCSW421E0A ACP Premium ‐ PQCPC22A1 ACP Standard ‐ PQCPC22N1 LonWorks Gateway ‐ PQNFB16A1 Washable Pre‐filter Primary Filter Net Unit Weight (lbs) 39 Shipping Weight (lbs) 45 Fan: Type Sirocco 2 Quantity Motor/Drive •Internal Condensate Pump •Inverter (variable speed fan) •Group control 30/26/23 Brushless Digitally Controlled/Direct 318/247/194 Airflow Rate H/M/L (CFM) External Static Pressure³ ⁴ (in wg) Minimum External Static Pressure⁵ Maximum External Static Pressure⁵ 0.1 0.0 0.2 Notes: 1.Acceptable opera ng voltage: 187V‐253V. 2.Sound Pressure levels are tested in an anechoic chamber under ISO Standard 1996. 3.Adjust fan speed to correct for sta c pressure increases when using field supplied air filter. 4.At factory fan speed setting. 5.Air flow rate (CFM) at high speed. 6.See Engineering Manual for sensible and latent capaci es. 7.All power/communica on cable to be minimum 18 American wire gage (AWG), 4‐ conductor, stranded, shielded and must comply with applicable local and national code. 8.Power wiring cable size must comply with the applicable local and na onal code. 9.This unit comes with a dry helium charge. 10.Corresponding refrigerant piping length is in accordance with standard length of each outdoor unit and the level difference is 0 ft. 11.Must follow installation instructions in the applicable LG installation manual. BACnet Gateway ‐ PQNFB17C1 AC Ez ‐ PQCSZ250S0 Dry Contact Unit Dry Contact Unit (1 contact, 24 VAC external power) ‐ PQDSB1 Dry Contact Unit Dry Contact Unit (2 input, power from indoor unit) ‐ PQDSBC Dry Contact for Third Party Thermostat ‐ PQDSBNGCM1 For a complete list of available accessories, contact your LG representative. For continual product development, LG reserves the right to change specifications without notice. LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG Life’s Good” is a registered trademark of LG Corp. /www.lghvac.com SB‐MultiF‐LMDN096HV‐04‐15 Page 1 of 2 Job Name/Location: LMDN096HV Tag #: Multi F Ceiling Concealed Duct 9,000 Btu/h Indoor Unit Date: For continual product development, LG reserves the right to change specifications without notice. LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG Life’s Good” is a registered trademark of LG Corp. /www.lghvac.com PO No.: SB‐MultiF‐LMDN096HV‐04‐15 Page 2 of 2
advertising