LG | LMDN096HV | Specifications | LG LMDN096HV Specifications

Job Name/Location:
Tag #:
Date:
For:
PO No.:
Architect:
GC:
Engr:
Mech:
File
Resubmit
Approval
Other
Rep:
(Company)
(Project Manager)
LMDN096HV
Multi F Ceiling Concealed Duct
9,000 Btu/h Indoor Unit
Performance:
Operating Range:
Nominal Cooling Capacity (Btu/h)
Nominal Heating Capacity (Btu/h)
Cooling Nominal Test Conditions:
Indoor: 80°F DB/67°F WB
Outdoor: 95°F DB/75°F WB
9,000
10,400
Heating Nominal Test Conditions:
57‐77
Heating (°F DB)
59‐81
Unit Data:
Indoor: 70°F DB/60°F WB
Outdoor: 47°F DB/43°F WB
Refrigerant Type
Electrical:
R410A
EEV
Refrigerant Control
Power Supply (V¹/Hz/Ø)
208‐230/60/1
0.40
Rated Amps (A)
Piping:
Liquid Line (in, OD)
1/4
Vapor Line (in, OD)
3/8
1‐1/4, 1
Drain OD, ID (in)
Thermistor
Temperature Sensor
Features:
•2 Thermistor control
•Auto opera on
•Auto restart
•Control lock func on
Cooling (°F WB)
Sound Pressure² H/M/L (±3 dB(A))
Included Accessories:
•Simple Controller with Mode ‐ AKB72955816
Optional Accessories (sold separately
LG Programmable Thermostat ‐ PREMTB10U0
Simple Controller with Mode (Black) ‐ PQRCVCL0Q
Simple Controller with Mode (White) ‐ PQRCVCL0QW
Simple Controller without Mode (Black) PQRCHCA0Q
Simple Controller without Mode (White) ‐ PQRCHCA0QW
AC Smart Premium ‐ PQCSW421E0A
ACP Premium ‐ PQCPC22A1
ACP Standard ‐ PQCPC22N1
LonWorks Gateway ‐ PQNFB16A1
Washable Pre‐filter
Primary Filter
Net Unit Weight (lbs)
39
Shipping Weight (lbs)
45
Fan:
Type
Sirocco
2
Quantity
Motor/Drive
•Internal Condensate Pump
•Inverter (variable speed fan)
•Group control
30/26/23
Brushless Digitally Controlled/Direct
318/247/194
Airflow Rate H/M/L (CFM)
External Static Pressure³ ⁴ (in wg)
Minimum External Static Pressure⁵
Maximum External Static Pressure⁵
0.1
0.0
0.2
Notes:
1.Acceptable opera ng voltage: 187V‐253V.
2.Sound Pressure levels are tested in an anechoic chamber under ISO Standard 1996.
3.Adjust fan speed to correct for sta c pressure increases when using field supplied air
filter.
4.At factory fan speed setting.
5.Air flow rate (CFM) at high speed.
6.See Engineering Manual for sensible and latent capaci es.
7.All power/communica on cable to be minimum 18 American wire gage (AWG), 4‐
conductor, stranded, shielded and must comply with applicable local and national code.
8.Power wiring cable size must comply with the applicable local and na onal code.
9.This unit comes with a dry helium charge.
10.Corresponding refrigerant piping length is in accordance with standard length of each
outdoor unit and the level difference is 0 ft.
11.Must follow installation instructions in the applicable LG installation manual.
BACnet Gateway ‐ PQNFB17C1
AC Ez ‐ PQCSZ250S0
Dry Contact Unit Dry Contact Unit (1 contact, 24 VAC external power) ‐ PQDSB1
Dry Contact Unit Dry Contact Unit (2 input, power from indoor unit) ‐ PQDSBC
Dry Contact for Third Party Thermostat ‐ PQDSBNGCM1
For a complete list of available accessories, contact your LG representative.
For continual product development, LG reserves the right to change specifications without notice.
LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG Life’s Good” is a registered trademark of LG Corp. /www.lghvac.com
SB‐MultiF‐LMDN096HV‐04‐15
Page 1 of 2
Job Name/Location:
LMDN096HV
Tag #:
Multi F Ceiling Concealed Duct
9,000 Btu/h Indoor Unit
Date:
For continual product development, LG reserves the right to change specifications without notice.
LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG Life’s Good” is a registered trademark of LG Corp. /www.lghvac.com
PO No.:
SB‐MultiF‐LMDN096HV‐04‐15
Page 2 of 2