GE Zoneline®
Packaged
Terminal Air
Conditioners
Product Guide
GE Zoneline
®
A Story of American Invention
In 1961, the GE Zoneline® PTAC began making its way into hotels and
motels across the country, changing the face of comfort on the road.
Now, over 50 years later, GE Zoneline has been reinvented in Louisville,
Kentucky, to meet the changing needs of America’s hotel industry.
The newest GE Zoneline PTACs are engineered to be more reliable,
efficient, quieter and incredibly easy to install and maintain.
2
Key benefits
GE Zoneline is an industry leader
in four categories:
reliable
Quiet
efficient
Appearance
3
4
REliable
With over one million units installed across the U.S., and with remarkably low service issues, GE
Zoneline® PTACs offer unrivaled reliability, consistent performance and constant guest comfort.
Unmatched Service & support
Our technicians service your Zoneline—and any other GE appliances you have—in no time,
so guest comfort is not compromised.
feature highlights:
Simplified structure
| Easy to maintain and service.
premium guard corrosion Protection | Special coatings keep
each part performing at peak condition, longer.
Easy to Service | Zonelines have integrated structural components
for easy maintenance and support.
Durable design
| Rustproof base pan comes standard on all models.
Service diagnostics port | Technicians can quickly diagnose problems.
Quick connect | The thermostat, central desk control and external fan
can be connected in seconds for faster installation and servicing.
5
6
Quiet
Quiet operation is a strong suit of GE Zoneline®. It's the industry's quietest PTAC*, so you know
your guests will always get a good night’s rest.
where it counts
Typical outdoor noises such as those from traffic or airports present challenges to hotel owners every
day. When tested against leading competitors, GE Zonelines block the most outdoor noise with a sound
transmission class of 29*—that’s the highest PTAC STC on the market. That means Zonelines help guests
sleep better and can support high guest ratings for hotel and motel properties.
BEST STC
Guests who are dissatisfied with
the room noise or temperature:
against leading competitors*
29
(Sound Transmission Class)
Standard on all units. Higher is better.
33%
Are NOT likely
to recommend
THE HOTEL**
GE
Zoneline
Amana
q series
LG
Amana
friedrich
66%
Are NOT likely
to return TO
THE HOTEL**
GE Appliances Zonelines provide quiet comfort for hotel rooms.
feature highlights:
Baked-on mastic Sound Barrier | A heavy-duty barrier covers the back of the unit for superior
sound insulation.
Weather barrier system seal | A seal around the perimeter of the unit keeps noise and dirt outside.
Two DC fan motors | A motor for each fan reduces noise by dialing in the exact airflow needed for each
heating and cooling function.
Large Cross-flow blower | Airflow is optimized for a low, balanced sound that is hardly noticeable.
Smart fan cooling/heating | Allows the fan to run in either continuous mode during hot weather
or cycle mode during the winter months, saving energy and improving guest comfort.
* W hen compared to leading competitors. 12,000 BTUh heat pump models tested by independent third-party testing at a national acoustical lab, conducted March 2015 and
October 2015, in accordance with ASTM and AHRI standards. The higher the STC rating, the better the unit blocks outside noise.
**Clarabridge Ratings and Reviews, for hospitality data collected July 2013 – June 2014. “Americans' biggest complaints about hotels” Forbes Magazine, July 27, 2012 issue.
7
8
Efficient
GE Zoneline® PTACs are highly efficient. Zoneline heat pumps can save a property hundreds of dollars
per month in utility expenses.* On average Zoneline is 7% more efficient than the leading competitor.**
Why it matters
Decreasing the energy usage of your properties can save you a lot of money.
Since Zoneline PTACs are one of the industry leaders in efficient operation,
you’ll be able to cut utility bills without compromising comfort.
feature highlights:
Reverse cycle defrost | Prolongs heat pump operation, saving
energy and money.
Electronic temperature limiting | Limits are preset to save
energy and avoid excessive temperature swings.
Heat & freeze sentinels | Specially designed sentinels protect your
property by preventing overheating or freezing.
Extensive heat source logic | Smart technology lets each unit
automatically select the right heat source to efficiently meet guest needs.
Smart programming | Every unit is programmed to balance guest
comfort with efficient operation.
*Savings depend on region, equipment, structure and other factors.
**Zoneline AZ45 and AZ65 series base models, average for EER & COP ratings
per AHRI listing May 2016. Efficiency benefits may vary by model and region.
9
10
Appearance
GE Zoneline® boasts a slim room front, sleek appearance and light color that blends in seamlessly
with any hotel décor and room design. With an industry-standard 42" x 16" cutout and the industry’s
slimmest room front, Zoneline provides more open, usable space in the room itself.
Streamlined, Inside and out
Zoneline is sleek on the outside, and is also more efficiently engineered inside.
feature highlights:
Backlit, coverless control panel | Attractive display with large, white LED lights
and no control panel cover keep this unit looking like new.
Sleek appearance | 42" x 16" cutout with a shallow depth provides more usable room space.
Light color | Perfectly blends in with modern interior designs.
Dimming display | Automatic dimming feature makes sure LED lights are never too bright at night.
11
Feature Highlights
GE Zoneline® has a legacy of energy efficiency and guest comfort,
thanks to innovative features that property managers love.
premium guard
Corrosion Protection*
Special coatings, paintings and stainless steel ensure
lasting performance in challenging environments such as
oceanfront properties.
BAKED-ON MASTIC SOUND BARRIER
A heavy-duty barrier covers the back of the unit for
superior sound insulation.
MAKEUP AIR*
An included secondary system provides continuous
outdoor air. The supplemental dehumidification system
operates when relative humidity levels rise above 55%.
Available on select models.
Internal Condensate
Removal (ICR)*
A system of drainpipes and pump minimizes
the amount of condensate draining from the
unit when in heat pump mode.
Dry air 25*
System compatibility
Zoneline Dry Air models remove 20%-35% more moisture
from the air than standard Zoneline air conditioners**,
making them perfect for high humidity climates.
ompatible with a wide variety of thermostats
C
and energy management systems, including
central desk control.
*Available on select models.
**Varies when comparing dehumidification rates of the 7,000/9,000/12,000BTU
base models to their Dry Air model counterparts. AZ45 Series electric resistance models only.
12
Blower & DC Motors
Heat Pump features
Large cross-flow blower, two DC fan motors and smart
fan cooling and heating keep the unit quiet while
providing efficient heating and cooling performance.
Reverse cycle defrost increases efficiency and allows unit to
run in heat pump mode longer.
Heat & freeze sentinel
Electronic touch controls
Keeps room from overheating or freezing to increase
efficiency and comfort while decreasing operating and
maintenance costs.
asy-to-use controls with clear LED readout
E
provide a user-friendly experience.
weather barrier system seal
Electronic temperature limiting
Keeps noise, dirt and grime outside.
Prevents expensive overcooling and overheating of rooms.
Creates a quieter room and more efficient operation.
Limits are automatically set, so seasonal adjustments
aren’t necessary.
Backup resistance heat delivers quick heating comfort.
13
Zoneline® PACKAGED Terminal air conditioners
AZ45 Series | Cooling and electric heat
• Digital LED display
• Variable vent control
• Quiet fans, blowers and
motors:
– Cross-flow blower
– Two DC fan motors
– Smart fan cooling
• Heat and Freeze Sentinel
• Remote thermostat
capability
• Electronic temperature
limiting
• Works with central desk
control and remote
thermostats
BASE
PREMIUM GUARD CORROSION PROTECTION
DRY AIR 25
AZ45E07DAB
AZ45E07DAC
AZ45E07EAC
AZ45E07DAP
AZ45E09EAP
7,200/7,000 BTU
13.4/13.4 EER
230/208 Volts
7,200/7,000 BTU
13.4/13.4 EER
230/208 Volts
7,300 BTU
13.4 EER
265 Volts
6,900/6,800 BTU
12.8/12.8 EER
230/208 Volts
9,500 BTU
12.1 EER
265 Volts
AZ45E09DAB
AZ45E09DAC
AZ45E09EAC
AZ45E09DAP
AZ45E12EAP
9,700/9,600 BTU
12.1/12.1 EER
230/208 Volts
9,400/9,300 BTU
11.8/11.8 EER
230/208 Volts
9,500 BTU
11.6 EER
265 Volts
9,400/9,300 BTU
12.1/12.1 EER
230/208 Volts
11,000 BTU
11.0 EER
265 Volts
AZ45E12DAB
AZ45E12DAC
AZ45E12EAC
AZ45E12DAP
11,900/11,800 BTU
11.8/11.8 EER
230/208 Volts
AZ45E15DAB
14,900/14,800 BTU
10.5/10.5 EER
230/208 Volts
11,800/11,600 BTU
11.5/11.5 EER
230/208 Volts
11,800 BTU
11.7 EER
265 Volts
AZ45E15DAC
AZ45E15EAC
14,600/14,500 BTU
10.5/10.5 EER
230/208 Volts
11,200/11,100 BTU
11.5/11.5 EER
230/208 Volts
14,900 BTU
10.7 EER
265 Volts
AZ65 Series | Heat pump
Includes all resistant heat
features, plus:
• Staged heating
• Heat pump with
supplemental
resistance heat
• Reverse cycle defrost
*Coefficient of Performance
14
BASE
PREMIUM GUARD CORROSION PROTECTION
internal condensate removal
AZ65H07DAB
AZ65H07DAC
AZ65H07EAC
AZ65H07DAD
AZ65H07EAD
7 ,100/6,900 cooling
BTU, 6,200/6,100
heating BTU, 13.0/
13.0 EER, 4.0/4.0
COP*, 230/208 Volts
7 ,100/7,000 cooling
BTU, 6,200/6,100
heating BTU, 13.0/
13.0 EER, 4.0/4.0
COP*, 230/208 Volts
7,000 cooling BTU,
6,200 heating BTU,
12.8 EER, 3.9 COP*,
265 Volts
7,000/6,900 cooling BTU
6,200/6,000 heating BTU
13.0/13.0 EER
4.0/4.0 COP*
230/208 Volts
7,000 cooling BTU
6,200 heating BTU
12.8 EER
3.9 COP*
265 Volts
AZ65H09DAB
AZ65H09DAC
AZ65H09EAC
AZ65H09DAD
AZ65H09EAD
9,700/9,600 cooling
BTU, 8,100/8,000
heating BTU, 12.2/
12.2 EER, 3.7/3.7
COP*, 230/208 Volts
9,700/9,600 cooling
BTU, 8,100/8,000
heating BTU, 12.2/
12.2 EER, 3.7/3.7
COP*, 230/208 Volts
,500 cooling BTU,
9
8,100 heating BTU,
11.7 EER, 3.6 COP*,
265 Volts
9,600/9,500 cooling BTU
8,200/8,000 heating BTU
12.0/12.0 EER
3.6/3.6 COP*
230/208 Volts
,500 cooling BTU
9
8,100 heating BTU
11.7 EER
3.5 COP*
265 Volts
AZ65H12DAB
AZ65H12DAC
AZ65H12EAC
AZ65H12EAD
1 1,900/11,800 cooling
BTU, 10,400/10,300
heating BTU, 11.7/
11.7 EER, 3.6/3.6
COP*, 230/208 Volts
11,900 cooling BTU,
10,500 heating BTU,
11.6 EER, 3.6 COP*,
265 Volts
AZ65H12DAD
12,100/11,900 cooling
BTU, 10,500/10,400
heating BTU, 11.9/
11.9 EER, 3.6/3.6
COP*, 230/208 Volts
11,800/11,600 cooling BTU
10,400/10,200 heating BTU
11.5/11.5 EER
3.5/3.5 COP*
230/208 Volts
11,900 cooling BTU
10,300 heating BTU
11.7 EER
3.4 COP*
265 Volts
AZ65H15DAB
AZ65H15DAC
AZ65H15EAC
AZ65H15DAD
AZ65H15EAD
1 4,400/14,200 cooling
BTU, 13,400/13,300
heating BTU, 10.6/
10.6 EER, 3.3/3.3
COP*, 230/208 Volts
14,500/14,200
cooling BTU,
13,500/13,300
heating BTU, 10.4/
10.4 EER, 3.3/3.3
COP*, 230/208 Volts
14,500 cooling BTU,
13,500 heating BTU,
10.6 EER, 3.3 COP*,
265 Volts
14,300/14,100 cooling BTU
13,500/13,400 heating BTU
10.3/10.3 EER
3.2/3.2 COP*
230/208 Volts
14,300 cooling BTU
13,500 heating BTU
10.4 EER
3.2 COP*
265 Volts
AZ65 Series | Heat Pump Makeup Air
AZ45 Series | Resistant Heat Makeup Air
• Delivers 35 CFM of continuous, makeup air
makeup air
• Conditions incoming air when relative
humidity outdoors is above 55%
AZ45E09DAM
• Quiet operation
– Baked-on mastic
– Cross-flow blower
– Two DC fan motors
AZ45E12DAM
• Heat & Freeze Sentinels
• Electronic temperature limiting
• Electronic touch controls with LED display
Includes all resistant heat makeup air features, plus:
• Reverse heat cycle
9,200/9,100 BTU
11.5/11.5 EER
230/208 Volts
11,600/11,500 BTU
11.4/11.4 EER
230/208 Volts
• May reduce the need for rooftop units
• Product is built to order
NOTE: Because makeup air increases room BTU load
requirements and requires additional PTAC cooling or
heating, the building’s electrical needs may be impacted.
• Boost heat option
makeup air
AZ65H07DAM
AZ65H09DAM†
AZ65H12DAM
6,700/6,600 cooling
BTU, 6,100/6,000
heating BTU, 12.0/
12.0 EER, 3.6/3.6
COP*, 230/208 Volts
9,200/9,100 cooling
BTU, 8,100/8,000
heating BTU, 11.5/
11.5 EER, 3.5/3.5
COP*, 230/208 Volts
11,500/11,400 cooling
BTU, 10,400/10,300
heating BTU, 11.2/
11.2 EER, 3.5/3.5
COP*, 230/208 Volts
NOTE: Makeup air models listed above
are not recommended for installation
within two miles of coastal areas.
NOTE: It is strongly recommended to
install makeup air with wall thermostats.
Zoneline® Accessories
Wall Case Options
Grille Options
Retrofit Kits
RAB71B, RAB77B
Architectural rear grille
Extruded aluminum – RAG67
Stamped aluminum – RAG60
RAK40 Deflector kit
Extended sleeves also available in 16"
and 24" depths
High-impact polymer grille
Beige – RAG61
Maple – RAG62
Dark Brown – RAG63
Thermostats
AZ45 SERIES
AZ65 SERIES
Cooling with electric heat
digital remote thermostat
Heat pump digital
remote thermostat
RAK164D2
RAK164F2
Standard sub-base with
power cord included
RAK204D15C-15 Amp
RAK204D20C-20 Amp
RAK204D30C-30 Amp
Digital two fan speed
thermostat for electric
resistance
RAK164P2
Cooling with electric heat
programmable remote
thermostat
RAK148D2
RAK148F2
Digital two fan speed
thermostat for heat pump
RAK148P2
Heat pump programmable
remote thermostat
Additional accessories available
For example, drain kits, adapter, exterior air deflector kits and filters.
Visit Zoneline.com for full listing.
15
Power connection kits are required
on all ge Zoneline chassis. (See chart below)
The correct kit for the installation is determined by the voltage and amperage of the electrical circuit and the means of
connecting the unit to the building wiring. If the unit is to be plugged into a receptacle, a line cord kit would be used; if
the unit is to be permanently connected, a permanent connection kit would be used. Cord set units of 265 volts must be
installed in compliance with National Electrical Code.®
power connection Kits
Required on all models. See specification information below
for heater kWh and branch circuit ampacity.
RAK315P/320P/330P
RAK315D/320D/330D
RAK515D/520D/530D
230/208 volt line cord connection kit
230/208 volt universal power supply kit
265 volt universal power supply kit
Also available with short power cords
Receptacles/Sub-bases
Tandem
230/208V 15 Amp
NEMA6-15R
Perpendicular
230/208V 20 Amp
NEMA6-20R
Large tandem
230/208V 30 Amp
NEMA6-30R
265V 15 amp
NEMA7-15R;
receptacle used on
265V sub-base
265V 20 amp
NEMA7-20R;
receptacle used on
265V sub-base
ge Zoneline specifications­— heater wattage
BTUh size
Power connection kit
Total watts
Heater watts
Heater BTUh
Total amps
Min. circuit
Recommended
protective device
BTUh size
Power connection kit
Total watts
Heater watts
Heater BTUh
Total amps
Min. circuit
Recommended
protective device
230/208-Volt Line-Cord Connected (P) and Direct Connected Units (D)
7,000/9,000
12,000/15,000
RAK315P &
RAK315D
2,410/1,990
2,400/1,960
8,100/6,600
10.5/9.6
15
RAK320P &
RAK320D
3,420/2,830
3,400/2,780
11,600/9,400
14.9/13.6
20
RAK330P &
RAK330D
4,830/3,990*
4,800/3,930*
16,300/13,400*
21.0/19.2
30
RAK315P &
RAK315D
2,430/2,020
2,400/1,960
8,100/6,600
10.6/9.7
15
RAK320P &
RAK320D
3,450/2,860
3,400/2,780
11,600/9,400
15.1/13.8
20
RAK330P &
RAK330D
4,860/4,020*
4,800/3,930*
16,300/13,400*
21.2/19.3
30
15 amp
time-delay fuse
or breaker
20 amp
time-delay fuse
or breaker
30 amp
time-delay fuse
or breaker
15 amp
time-delay fuse
or breaker
20 amp
time-delay fuse
or breaker
30 amp
time-delay fuse
or breaker
265-Volt
Permanent (P, Cord Set) and Direct-Connected Units (D)
7,000/9,000
12,000/15,000
RAK515P &
RAK515D
2,440
2,400
8,100
9.1
15
15 amp
time-delay fuse
or breaker
RAK520P &
RAK520D
3,450
3,400
11,600
12.9
20
20 amp
time-delay fuse
or breaker
RAK530P &
RAK530D
4,850*
4,800*
16,300*
18.1
30
30 amp
time-delay fuse
or breaker
RAK515P &
RAK515D
2,460
2,400
8,100
9.3
15
15 amp
time-delay fuse
or breaker
RAK520P &
RAK520D
3,470
3,400
11,600
13.1
20
20 amp
time-delay fuse
or breaker
RAK530P &
RAK530D
4,870*
4,800*
16,300*
18.4
30
30 amp
time-delay fuse
or breaker
Each line cord kit has an integral Leakage Current Detection and Interruption (LCDI) device as required by
National Electrical Code (NEC) and Underwriters Laboratories (UL) for units manufactured after August 1, 2004.
Specifications subject to change.
Wall case and exterior grille are also required for new construction.
*30 AMP heater wattage will be reduced in low fan operation
16
265V 30 amp
NEMA7-30R;
receptacle used on
265V sub-base
Zoneline packaged terminal Air Conditioner specifications
230/208V Models
Cooling BTUH
EER (BTU/Watt)
Dehumidification Pts/Hr
Refrigerant type
CFM, indoor fan high
CFM, indoor fan low
Vent CFM (full open)
Power factor
Sensible heat ratio
@ 230 volts
Cooling Watts
Cooling Amperes, F.L.
Amperes, L.R.
Weight (Net/Ship)
230/208V Models
Cooling BTUH
EER (BTU/Watt)
Dehumidification Pts/Hr
Refrigerant type
CFM, indoor fan high
CFM, indoor fan low
Vent CFM (full open)
Power factor
Sensible heat ratio
@ 230 volts
Cooling Watts
Cooling Amperes, F.L.
Amperes, L.R.
Weight (Net/Ship)
230/208V Models
Cooling BTUH
EER (BTU/Watt)
Dehumidification Pts/Hr
Refrigerant Type
CFM, indoor fan high
CFM, indoor fan low
Vent CFM (full open)
Power factor
Sensible heat ratio
@ 230 volts
Cooling Watts
Cooling Amperes, F.L.
Amperes, L.R.
Weight (Net/Ship)
230/208V Models
Cooling BTUH
EER (BTU/Watt)
Dehumidification Pts/Hr
Refrigerant type
CFM, indoor fan high
CFM, indoor fan low
Vent CFM (full open/)
Power factor
Sensible heat ratio
@ 230 volts
Cooling Watts
Cooling Amperes, F.L.
Amperes, L.R.
Weight (Net/Ship)
AZ45 series (typical) cooling with electric heat
AZ45E07DAB AZ45E09DAB AZ45E12DAB AZ45E15DAB
7,200/7,000
13.4/13.4
1.7
R-410A
409
250
33
96%
9,700/9,600
12.1/12.1
2.7
R-410A
409
280
38
98%
11,900/11,800
11.8/11.8
3.5
R-410A
449
270
42
98%
14,900/14,800
10.5/10.5
4.6
R-410A
449
300
47
97%
70%
535/520
2.5/2.6
13.5
90/100
64%
800/790
3.6/3.9
21.0
103/113
60%
1,010/1,000
4.7/5.0
29.5
106/116
63%
1,415/1,405
6.4/6.8
31.5
106/116
AZ45 series cooling with electric heat (Premium Guard Corrosion Protection)
AZ45E07DAC AZ45E09DAC AZ45E12DAC AZ45E15DAC
265V Models
7,200/7,000
13.4/13.4
1.6
R-410A
409
250
33
96%
9,400/9,300
11.8/11.8
2.7
R-410A
409
280
38
98%
11,800/11,600
11.5/11.5
3.5
R-410A
449
270
42
98%
14,600/14,500
10.5/10.5
4.6
R-410A
449
300
47
97%
74%
535/520
2.5/2.6
13.5
90/100
64%
795/790
3.5/3.9
21
103/113
60%
1,020/1,005
4.5/4.9
29.5
106/116
63%
1,390/1,380
6.3/6.7
31.5
106/116
AZ45 series cooling with electric heat (Dry Air 25)
AZ45E07DAP
AZ45E09DAP
AZ45E12DAP
6,900/6,800
12.8/12.8
2.3
R-410A
320
230
40.0
96%
9,400/9,300
12.1/12.1
3.4
R-410A
370
280
44.0
97%
11,200/11,100
11.5/11.5
4.2
R-410A
360
270
44
98%
61%
535/530
2.5/2.7
13.5
96/106
58%
775/765
3.5/3.8
21.0
109/119
54%
970/960
4.4/4.7
29.5
112/122
Cooling BTUH
EER (BTU/Watt)
Dehumidification Pts/Hr
Refrigerant type
CFM, indoor fan high
CFM, indoor fan low
Vent CFM (full open)
Power factor
Sensible heat ratio
@ 265 volts
Cooling Watts
Cooling Amperes, F.L.
Amperes, L.R.
Weight (Net/Ship)
265V Models
Cooling BTUH
EER (BTU/Watt)
Dehumidification Pts/Hr
Refrigerant type
CFM, indoor fan high
CFM, indoor fan low
Vent CFM (full open)
Power factor
Sensible heat ratio
@ 265 volts
Cooling Watts
Cooling Amperes, F.L.
Heating Amperes
Weight (Net/Ship)
AZ45E07EAC AZ45E09EAC AZ45E12EAC AZ45E15EAC
7,300
13.4
1.7
R-410A
409
250
33
95%
9,500
11.6
2.7
R-410A
409
280
38
94%
11,800
11.7
3.5
R-410A
449
270
42
97%
14,900
10.7
4.6
R-410A
449
300
47
98%
72%
540
2.2
11.7
95/105
67%
815
3.3
16.5
103/113
61%
1,005
4.0
23.5
106/116
59%
1,390
5.4
26.0
107/117
AZ45E09EAP
AZ45E12EAP
9,500
12.1
3.5
R-410A
370
280
44
93%
11,000
11.0
4.2
R-410A
360
270
44
97%
58%
780
3.2
16.5
109/119
54%
995
3.9
23.5
112/122
AZ45 series cooling with electric heat (makeup air)
AZ45E09DAM
AZ45E12DAM
9,200/9,100
11.5/11.5
1.8
R-410A
409
280
35
98%
11,600/11,500
11.4/11.4
3.2
R-410A
449
270
35
98%
78%
800/790
4.8/5.1
21.0
122/132
69%
1,010/1,005
5.8/6.1
29.5
125/135
*Coefficient of Performance
Listed by
Underwriters
Laboratories
17
Zoneline® packaged terminal Air Conditioner specifications
230/208V Models
Cooling BTUH
EER (BTU/Watt)
Dehumidification Pts/Hr
Refrigerant type
CFM, indoor fan high
CFM, indoor fan low
Vent CFM (full open)
Power factor
Sensible heat ratio
@ 230 volts
Cooling Watts
Cooling Amperes, F.L.
Amperes, L.R.
Reverse cycle heat BTUH
Coefficient of Performance
Heating Watts
Heating Amperes
Weight (Net/Ship)
230/208V Models
AZ65 (typical) series heat pump with backup electric heat (Premium Guard Corrosion Protection)
AZ65H07DAC AZ65H09DAC AZ65H12DAC AZ65H15DAC
265V Models
AZ65H07EAC AZ65H09EAC AZ65H12EAC AZ65H15EAC
7,100/7,000
13.0/13.0
1.6
R-410A
409
250
38
96%
9,700/9,600
12.2/12.2
2.6
R-410A
409
300
40
98%
11,900/11,800
11.7/11.7
3.7
R-410A
449
300
45
98%
14,500/14,200
10.4/10.4
4.8
R-410A
449
290
44
97%
73%
545/535
2.5/2.7
13.5
6,200/6,100
4.0/4.0
450/445
2.1/2.2
98/108
68%
795/785
3.6/3.9
21.0
8,100/8,000
3.7/3.7
645/630
2.9/3.1
106/116
62%
1,015/1,005
4.5/4.9
29.5
10,400/10,300
3.6/3.6
845/815
3.8/4.0
104/114
60%
1,390/1,360
6.2/6.7
31.5
13,500/13,300
3.3/3.3
1,195/1,180
5.4/5.7
108/118
Cooling BTUH
EER (BTU/Watt)
Dehumidification Pts/Hr
Refrigerant type
CFM, indoor fan high
CFM, indoor fan low
Vent CFM (full open)
Power factor
Sensible heat ratio
@ 265 volts
Cooling Watts
Cooling Amperes, F.L.
Amperes, L.R.
Reverse cycle heat BTUH
Coefficient of Performance
Heating Watts
Heating Amperes
Weight (Net/Ship)
AZ65 series heat pump with backup electric heat (Internal Condensate Removal)
AZ65H07DAD AZ65H09DAD AZ65H12DAD AZ65H15DAD
265V Models
Cooling BTUH
EER (BTU/Watt)
Dehumidification Pts/Hr
Refrigerant type
CFM, indoor fan high
CFM, indoor fan low
Vent CFM (full open)
Power factor
Sensible heat ratio
@ 230 volts
Cooling Watts
Cooling Amperes, F.L.
Amperes, L.R.
Reverse cycle heat BTUH
Coefficient of Performance
Heating Watts
Heating Amperes
Weight (Net/Ship)
7,000/6,900
13.0/13.0
1.6
R-410A
409
250
38.0
96%
9,600/9,500
12.0/12.0
2.6
R-410A
409
300
40.0
98%
11,800/11,600
11.5/11.5
3.7
R-410A
449
300
45.0
98%
14,300/14,100
10.3/10.3
4.8
R-410A
449
290
44.0
97%
73%
535/530
2.5/2.7
13.5
6,200/6,000
4.0/4.0
450/435
2.1/2.2
100/110
68%
800/790
3.6/3.9
21.0
8,200/8,000
3.6/3.6
665/650
3.0/3.2
108/118
62%
1,020/1,005
4.6/4.9
29.5
10,400/10,200
3.5/3.5
870/850
3.8/4.1
106/116
60%
1,385/1,360
6.1/6.6
31.5
13,500/13,400
3.2/3.2
1,235/1,225
5.3/5.6
110/120
230/208V Models
AZ65 series heat pump with backup electric heat
AZ65H07DAB AZ65H09DAB AZ65H12DAB
AZ65H15DAB
Cooling BTUH
EER (BTU/Watt)
Dehumidification Pts/Hr
Refrigerant type
CFM, indoor fan high
CFM, indoor fan low
Vent CFM (full open)
Power factor
Sensible heat ratio
@ 230 volts
Cooling Watts
Cooling Amperes, F.L.
Amperes, L.R.
Reverse cycle heat BTUH
Coefficient of Performance
Heating Watts
Heating Amperes
Weight (Net/Ship)
230/208V Models
Cooling BTUH
EER (BTU/Watt)
Dehumidification Pts/Hr
Refrigerant type
CFM, indoor fan high
CFM, indoor fan low
Vent CFM (full open)
Power factor
Sensible heat ratio
@ 230 volts
Cooling Watts
Cooling Amperes, F.L.
Amperes, L.R.
Reverse cycle heat BTUH
Coefficient of Performance
Heating Watts
Heating Amperes
Weight (Net/Ship)
Cooling BTUH
EER (BTU/Watt)
Dehumidification Pts/Hr
Refrigerant type
CFM, indoor fan high
CFM, indoor fan low
Vent CFM (full open)
Power factor
Sensible heat ratio
@ 265 volts
Cooling Watts
Cooling Amperes, F.L.
Amperes, L.R.
Reverse cycle heat BTUH
Coefficient of Performance
Heating Watts
Heating Amperes
Weight (Net/Ship)
7,100/6,900
13.0/13.0
1.7
R-410A
409
250
38
96%
9,700/9,600
12.2/12.2
2.6
R-410A
409
300
40
98%
12,100/11,900
11.9/11.9
3.7
R-410A
449
300
45
98%
14,400/14,200
10.6/10.6
4.8
R-410A
449
290
44
97%
79%
545/530
2.5/2.7
13.5
6,200/6,100
4.0/4.0
450/440
2.1/2.2
98/108
68%
795/785
3.6/3.8
21.0
8,100/8,000
3.7/3.7
645/630
3.0/3.2
104/114
62%
1,015/1,000
4.5/4.9
29.5
10,500/10,400
3.6/3.6
850/840
3.8/4.0
104/114
60%
1,355/1,335
6.1/6.5
31.5
13,400/13,300
3.3/3.3
1,190/1,180
5.2/5.6
107/117
7,000
12.8
1.5
R-410A
409
250
38
95%
9,500
11.7
2.5
R-410A
409
300
40
94%
11,900
11.6
3.7
R-410A
449
300
45
97%
14,500
10.6
4.8
R-410A
449
290
44
98%
77%
545
2.2
11.7
6,200
3.9
460
1.9
98/108
68%
810
3.3
16.5
8,100
3.6
655
2.8
104/114
62%
1,025
4.0
23.5
10,500
3.6
875
3.5
104/114
60%
1,365
5.3
26.0
13,500
3.3
1,195
4.6
109/119
AZ65H07EAD AZ65H09EAD AZ65H12EAD AZ65H15EAD
7,000
12.8
1.5
R-410A
409
250
38
95%
9,500
11.7
2.5
R-410A
409
300
40
94%
11,900
11.7
3.7
R-410A
449
300
45
97%
14,300
10.4
4.8
R-410A
449
290
44
98%
77%
545
2.2
11.7
6,200
3.9
460
1.9
98/108
68%
810
3.3
16.5
8,100
3.5
670
2.8
104/114
62%
1,015
4.0
23.5
10,500
3.4
885
3.5
104/114
60%
1,375
5.3
26.0
13,500
3.2
1,235
4.6
111/121
AZ65 series heat pump with backup electric heat (makeup air)
AZ65H07DAM
AZ65H09DAM
AZ65H12DAM
6,700/6,600
12.0/12.0
0.5
R-410A
409
250
35
98%
9,200/9,100
11.5/11.5
1.6
R-410A
409
300
35
98%
11,500/11,400
11.2/11.2
2.8
R-410A
449
300
35
98%
90%
555/550
3.8/3.9
13.5
6,100/6,000
3.6/3.5
485/480
3.4/3.6
117/127
80%
800/790
4.8/5.1
21.0
8,100/8,000
3.5/3.5
670/655
4.3/4.5
123/133
72%
1,020/1,010
5.9/6.3
29.5
10,400/10,300
3.5/3.5
860/840
5.2/5.4
123/133
Specifications subject to change.
Listed by
Underwriters
Laboratories
18
Zoneline warranty
for the period of
GE Appliances will replace
one year
Any part of the air conditioner which fails due to a defect in materials or workmanship. During this
limited one-year warranty, GE will provide, free of charge, all labor and related service costs to
replace the defective part.
five years
Sealed Refrigerating System, if any part of the Sealed Refrigerating System (the compressor,
condenser, evaporator, and all connecting tubing) should fail due to a defect in materials or
workmanship. During this limited five-year warranty, GE will provide, free of charge, all labor
and related service costs to replace the defective part.
second through
fifth year
Fan Motors, Switches, Thermostat, Heater, Heater Protectors, Compressor Overload, Solenoids,
Circuit Boards, Auxiliary Controls, Thermistors, Freeze Sentinel, Frost Controls, ICR Pump,
Capacitors, Varistors and Indoor Blower Bearing, if any of these parts should fail due to a defect in
materials or workmanship. During this additional four-year limited warranty, the customer will be
responsible for any labor and related service costs.
From the date of the
original purchase
From the date of the
original purchase
From the date of the
original purchase
Zoneline chassis nomenclature
A
Z
6
5
Zoneline
Chassis series
45=cool/electric heat
65=heat pump
Unit type
E=cooling with electric
resistance heat
H=heat pump with electric
resistance heat
H
1
2
Nominal cooling capacity
07=7,000 BTUh cooling
09=9,000 BTUh cooling
12=12,000 BTUh cooling
15=15,000 BTUh cooling
Voltage/Phase/Frequency
D=230/208 Volt, single
phase, 60 Hz
E=265 Volt, single phase,
60 Hz
DAD
Universal
power connection
Special features
B=base unit
C=Premium Guard
Corrosion Protection
D=internal condensate
removal (ICR)
system (heat pump
models only—
not for coastal
applications)
M=Makeup Air
P=Dry Air 25
Visit Zoneline.com for more information.
Listed by
Underwriters
Laboratories
19
Listed by
Underwriters
Laboratories
Appliance Park
Louisville, KY 40225
Appliance
Park of the General Electric Company.
GE is a trademark
Louisville,
KY
40225
Manufactured
under
trademark license.
geappliances.com
geappliances.com
zoneline.com
888.231.2548
Pub. No. 20-T0066 PC85111