Frigidaire FFHP094WS1 Installation Guide
Add to my manuals25 Pages
Frigidaire FFHP094WS1 is a reliable split type room air conditioner designed to provide efficient cooling and heating solutions for your indoor spaces. With its innovative features and powerful performance, this air conditioner offers a range of benefits to enhance your comfort and convenience. Let's dive into its key capabilities:
advertisement
▼
Scroll to page 2
of 25
All about the Installation of your Split Type Room Air Conditioner Refer to Page 2 for table of contents. www.frigidaire.ca Canada 1-866-942-1567 2020323B2335 (June 2009) www.frigidaire.com USA 1-866-942-1567 Welcome to the world of simple handling and no worries Thank you for choosing Frigidaire. This manual contains all of the information required to guarantee your safety and the appropriate use of your air conditioner. Please read all of the instructions before using the air conditioner and keep this manual for future reference. We know you will enjoy your new air conditioner and thank you for choosing our product. We hope you will consider us for future purchases. Environmental advices The packaging material used is recyclable. We recommend that you separate plastic, paper and cardboard and give them to recycling companies. If you need to dispose of this appliance in the future, do not throw it away with the rest of your domestic garbage. Attention!! The air conditioner that you have bought may be slightly different from the one illustrated in this manual. Please refer to the information related to the model you have. This air conditioner is for domestic use only. It is not recommended for heavy commercial or industrial use. 01 Welcome Contents 01. 02. 03. 04. 05. Welcome..........................................................................................01 Environmental advices........................................................................01 Contents...........................................................................................02 Safety precautions............................................................................. 03 Installation: 5.1 Choosing the installation site.................................................04 5.2 Parts list..............................................................................06 5.3 Indoor unit installation.......................................................... 08 5.4 Outdoor unit installation....................................................... 12 5.5 Refrigerant piping connection................................................14 5.6 Electrical work.....................................................................16 5.7 Purging the system............................................................... 20 5.8 Electrical safety....................................................................23 5.9 Gas leak check....................................................................23 5.10 Initial operation test..............................................................24 Contents 02 Safety precautions This appliance must be installed by a qualified licensed HVAC technician in accordance with all applicable codes. All electrical connections should be performed by a licensed electrician. Manufacturer's warranty will be voided with failure to comply. Incorrect Handling could result in Serious Injury or Death! 1. Do not attempt to install the split air conditioner by yourself. 2. This air conditioner contains no user-serviceable parts. Always call an authorized Electrolux servicer for repairs. 3. When moving the air conditioner, always call an authorized Frigidaire servicer for disconnection and reinstallation. 4. Do not insert fingers or place objects into the discharge area in the front of the indoor unit. 5. Do not insert fingers or place objects into the discharge area in the front of the outdoor unit. 6. Do not start or stop the air conditioner by turning off the power at the electrical box. 7. In the event of a malfunction (sparks, burning smell, etc.) immediately power off unit and call an authorized Frigidaire servicer. 8. Do not operate the air conditioner with wet hands. 9. Do not drink any water or condensation that is drained from the air conditioner. 10.Provide occasional ventilation during use. Do not direct airflow at fire places or other heat related sources as this could cause flare ups or make units run excessively. 03 Satety precautions 11. Do not climb on or place objects on the outdoor unit. 12. Do not hang objects off the indoor unit. 13. Do not place objects containing water on the indoor and/or outdoor units. 14. Turn off the air conditioner at the power source when it will not be used for an extended period of time. 15. Periodically check the condition of the outdoor unit’s installation base for any damage. 16. Do not apply heavy pressure to the coil fins of the indoor and/or outdoor units. 17. Operate the indoor unit with air filters in place. 18. Do not block or cover the intake grille, discharge area and outlet ports. 19. Ensure that any electrical/ electronic equipment is 36” away from the indoor unit and outdoor unit. 20. Do not use or store flammable gases near the indoor and/or outdoor units. Choosing the installation site Installation Warnings 1. Carefully read the installation manual before beginning. 2. Follow each step as shown. 3. Observe all local, state and national electric codes. This appliance must be installed by a qualified licensed HVAC technician in accordance with all applicable codes. All electrical connections should be performed by a licensed electrician. Failure to comply will result in a void of the manufacturer's warranty. 4. Pay attention to all safety notices. Precautions for Installation Installation at the following sites may cause problems. If you must inevitably install the unit at one of these sites, please consult your local distributor beforehand: 1. Sites with machine oil. 2. Sites with a high concentration of salinity, such as coastal areas. 3. Sites with sulfuric gas, such as hot water springs. 4. Sites with high frequency equipment, such as wireless equipment, welding machines and medical installations. 5. Sites with flammable gases or volatile material. 6. Sites with special environmental conditions. 7. Laundry rooms. Choosing the installation site 04 Indoor Unit 1. Install unit where air flow will not be obstructed. 2. The installation location must support the weight of the indoor unit. 3. The site must be easily accessible for maintenance and replacement of the air filter. 4. The installation location must allow for the necessary space around the indoor unit, as shown in the figure 1.1. 5. There should be at least 3 feet (1 meter) between the unit and radio or television devices. It is ideal that the unit be installed at the center of the wall. 6. The indoor unit must be kept away from fire, smoke and flammable gases. 7. We recommend the indoor unit to be installed as high up as possible on the inside wall (minimum of 7 feet high), always leaving a space of at least 6" between the top of the indoor unit and the ceiling. 8. The installation location must allow for the easy removal of the connector pipe and drain hose. 9. The unit must be installed at a location protected from direct sunlight. More than 6" More than 6" More than 6" Figure 1.1 Outdoor Unit 1. The outdoor unit must be installed at a convenient site that is not exposed to strong winds. The site should be dry and well ventilated. 2. The site must support the weight of the outdoor unit and allow for vertical installation. 3. The site must be kept away from flammable gases. 4. The site must provide enough space around the unit, as shown in figure 1.2. 5. Children must not be able to access the installation site. More than 8.5" More than 12" More than 12" 06 More than 78" 05 Choosing the installation site More than 2" Figure 1.2 More than 18.5" Part Lists Tools needs for installation 1. 2. 3. 4. 5. 6. 7. 8. Level gauge Screw driver Electric drill Hole core drill (ø55mm / ø70mm) Flaring tool set Specied torque wrenches Spanner (half union) A glass of water 9. 10. 11. 12. 13. 14. 15. 16. 17. Hexagonal wrench (4mm) Gas-leak detector Vacuum pump Gauge manifold Users manual Thermometer Multimeter Pipe cutter Measuring tape Accessories Number Name of Accessories Quantity 1 Indoor unit mounting plate 1 2 Clip anchor Not supplied 3 Self-tapping screw A ST3.9X25 5-8 4 Remote control 1 5 Remote control holder (Optional) 1 6 Screw for remote holder ST2.9X10 (Optional) 2 7 Battery (AAA 1.5V) 2 8 Insulation material Not supplied 9 Connection piping assembly(Optional) 1 10 Insulation hose for refrigerant piping Not supplied 11 Drain hose Not supplied 12 Wall clamp Not supplied 13 Connection power cable Not supplied 14 Drain connector (Heat Pump model only) 1 15 Drain plug (Heat Pump model only) (Optional) 2-3 16 Thermal insulating pipe for extending drain hose 1 17 Flare nut (for suction pipe) (Optional) 1 18 Flare nut (for liquid pipe) (Optional) 1 Note: Other necessary parts for the installation, besides the above mentioned, must be provided by the customer/installer. Part list 06 Product Description Space to the ceiling Indoor Unit 3 2 15cm above 1 Space to the wall 15cm above Space to the wall 15cm above bove 8 3m a 9 10 Air outlet side 4 11 5 6 Space to obstruction 50cm above 7 18 17 Air inlet side Space to the wall e ov 30cm above m 0c ab 3 16 15 14 ve o ab 2m Air outlet side 50cm above Space to the wall 12 NOTE 13 All the pictures in this manual are for explanation purposes only. The actual shape of the indoor unit you purchased may be slight different on front panel and display window.The actual shape shall prevail. 07 Part list Indoor unit installation Wall mounting brackets and dimensions 6" or more from the ceiling Wall mounting bracket Refrigerant pipe hole (right) Ø 2.56" 3.39" Refrigerant pipe hole (right) Ø 2.56" 3.39" A 6" or more from the wall B 4.21" 6" or more from the wall 4.21" Indoor unit outline ≤12000 Btu's (A:33.31" B:10.83") 6" or more from the ceiling A Indoor unit outline Wall mounting bracket 6" or more from the wall B 6" or more from the wall Refrigerant pipe hole (right) Ø 2.56" 1.58'' Refrigerant pipe hole (right) Ø 2.56" 1.58'' 7.91'' 5.31'' =18000 Btu's (A:36.97" B:11.73") 6" or more from the ceiling A Indoor unit outline Wall mounting bracket 6" or more from the wall B 6" or more from the wall Refrigerant pipe hole (right) Ø 2.56" 1.97'' 1.97'' 3.94'' Refrigerant pipe hole (right) Ø 2.56" 4.88'' =22000 Btu's (A:39.69" B:12.40") Indoor unit installation 08 6" or more from the ceiling A Indoor unit outline Wall mounting bracket 6" or more from the wall B 6" or more from the wall Refrigerant pipe hole (right) Ø 2.56" 1.97'' 1.97'' 3.94'' Refrigerant pipe hole (right) Ø 2.56" 4.88'' ≥28000 Btu's (A:53.15" B:12.83") Installing the Wall Mounting Bracket 1. Install the wall mounting bracket horizontally over the structural parts on the wall using the spaces indicated on the bracket, as shown in figure 1.3. 2. In the case of tiled, concrete or similar walls, create 13/64" diameter holes. Place anchor supports for the appropriate assembly screws. 3. Install the wall mounting bracket to the wall with eight A type screws. 4. At all times securing to the wall studs is recommended. Wall mounting bracket Figure 1.3 Attention!!! Fit the wall mounting bracket and drill holes in the wall according to the wall structure and corresponding mounting points on the wall mounting bracket (Dimensions are in “inches” unless otherwise stated). Wall 1. Determine the position of the hole for the pipes using the wall mounting bracket and drill the pipe hole so that it is tilted slightly downward. 2. Always use a pipe cover with an opening when drilling. 09 Indoor unit installation Indoor unit Outdoor unit 0.2"-0. 28" Drilling the Hole Connective pipe and drainage installation 1. For the left-hand and right-hand piping, remove the pipe cover from the side panel. The pipe cover can be kept as it may be used when relocating the air conditioner to any other place. 2. For the rear-right-hand and rearleft-hand piping, install the piping as shown in figure 1.4. Bend the connective pipe to be laid at a height of 1-11/16" or less from the wall. Fix the end of the connective pipe. Drainage 1. Run the drain hose sloping downward. Do not install the drain hose as illustrated in figure 1.5. 2. When connecting extension drain hose, insulate the connecting part of extension drain hose with a shield pipe, do not let the drain hose slack. Pipe cover (right) Pipe holder Pipe cover (left) Left piping Rear right piping Right piping Rear left piping Figure 1.4 Connective pipe Indoor unit outline 1-11/16" Connective pipe Do not block water flow by a rise. Do not block water flow by a rise. Do not put the end of drain hose into water. Figure 1.5 Fastening the Indoor Unit 1. Pass the piping through the hole in the wall. 2. Put the upper claw at the back of the indoor unit on the upper hook of the wall mounting bracket, move the indoor unit from side to side to see that it is securely hooked. Upper hook Lower hook Indoor unit installation 10 3. Piping can easily be made by lifting the indoor unit with a cushioning material between the indoor unit and the wall. 4. Push the lower part of the indoor unit up on the wall, Then move the indoor unit from side to side, up and down to check if it is hooked securely. Cushioning material Piping and wrapping 1. Bundle the tubing, connecting cable, and drain hose with tape securely and evenly as shown in the sideward figure. 2. Because the condensed water from rear of the indoor unit is gathered in ponding box and is piped out of room, do not put anything else in the box. Indoor unit Cable connection Ponding box Pipe room Connective pipe Drain hose Wrapping belt Attention!! 1. 2. 3. 4. Connect the indoor unit first, then the outdoor unit. Be careful not to let the drain hose slack. Both of the auxiliary piping should be heat insulated. Be sure that the drain hose is located at the lowest side of the bundle. Locating at the upper side may cause drain pan to overflow inside the unit. 5. Never intercross nor intertwist the power wire with any other wiring. 6. Run the drain hose sloped downward to drain out the condensed water smoothly. 11 Indoor unit installation Outdoor unit installation 1. Install the outdoor part of the unit on a flat surface to avoid excess noise and vibration. A condenser pad is recommended. 2. Direct the air vent toward an area without obstacles. 3. Install the unit at the site where it is exposed to as little wind as possible, especially in areas where it is frequently windy. 4. If the installation site is exposed to heavy winds, such as in coastal areas, place the unit along the widest part of the wall or use protective plates. 5. Be sure there is no obstacle which blocks exhausting air, including schrubs or bushes. Settlement of outdoor unit. Anchor the outdoor unit tightly and horizontally on a concrete or flat mount with a bolt and nut 2/5" or 5/16" diameter (Purchased separately). Strong wind Air inlet Air inlet Air outlet Capacity (BTU/h) Outdoor unit dimension inch(WxHxD) A (inch) B (inch) 9000 33-9/25 x 21-6/25 x 12-3/5 21-6/25 11-7/25 12000 33-9/25 x 23-6/25 x 12-3/5 22-2/25 14-4/25 18000 37-3/5 x 27-3/5 x 15-3/5 24-6/25 15-9/25 22000 38-3/5 x 31-1/10 x 16-3/5 26-4/25 17-7/25 28000 38-3/5 x 31-1/10 x 16-3/5 26-4/25 17-7/25 33600 38-3/5 x 31-1/10 x 16-3/5 26-4/25 17-7/25 26000 38-3/5 x 31-1/10 x 16-3/5 26-4/25 17-7/25 34400 42-4/5 x 43-4/5 x 17-3/10 31-3/25 18-3/25 Outdoor unit installation 12 Condensate drainage of outdoor unit (cooling only excluded) The condensate and defrosting water produced during heating in the outdoor unit can be properly discharged by drainage pipe. Installation method: Insert the drain connection into one of the holes of the chassis and then connect drainage pipe with drain nozzle. Insert drainage plugs (with different appearance) into the other holes. Drain connection Chassis 13 Outdoor unit installation Drainage Plug Refrigerant piping connection Unit comes with 25' tubing bundle. It is not recommended to cut. If too long, loop for excess. Note: Keep original bend so not kinking of the tube occurs. Flaring work Main cause for refrigerant leakage is due to defect in the flaring work. Carry out correct flaring work using the following procedure: 1. Cut the pipes and the cable. A) Use the piping kit accessory or pipes purchased locally. B) Measure the distance between the indoor and the outdoor unit. C) Cut the pipes a little longer than the measured distance. D) Cut the cable 5ft longer than the pipe length. 2. Burr removal A) Completely remove all burrs from the cut cross section of pipe/ tube. B) Put the end of the copper tube/ pipe in a downward direction as you remove burrs in order to avoid dropping burrs into the tubing. 3. Put nut on. Remove flare nuts attached to indoor and outdoor unit, then put them on pipe/tube having completed burr removal. (It is not possible to put them on after flaring work) Pipe Wrong Correct Oblique Roughness Burr Pipe Reamer Point down Flare nut Cooper tube Refrigerant piping connection 14 4. Flaring work. Firmly hold copper pipe in a die in the dimension shown in the table below. OUTER DIAMETER (inch) Bar Handle A (inch) Max. Min. 1/4 0.051 0.028 3/8 0.063 0.039 1/2 0.071 0.039 5/8 0.095 0.087 Copper pipe Yoke Red arrow mark Clamp handle Connection Adjustment 1. Align the pipes to be connected. 2. Screw the flare nut with your fingers, and then tighten it with a spanner and torque wrench, as shown in figure 1.6. Indoor unit tubing Flare nut Pipings Figure 1.6 Caution: Excessive twisting may break the nut, depending on the installation conditions. OUTER DIAMETER (inch) TIGHTENING TORQUE (lbf .in) 1/4 139 174 3/8 260 304 1/2 434 477 5/8 651 694 15 Refrigerant piping connection ADDITIONAL TIGHTENING TORQUE (lbf .in) Electrical work Electric safety regulations for the initial installation 1. If there is serious safety problem about the power supply, the technicians should refuse to install the air conditioner and explain to the client until the problem is solved. 2. Power voltage should meet the requirements in table 2.1. 3. Over current protection and circuit disconnect should meet the requirements in table 2.1 and the applicable local and national electrical codes. 4. Ensure the air conditioner is grounded well. 5. All wiring must comply with local and national electrical codes and be installed by qualified and skilled electricians. 6. An individual branch circuit used only for this air conditioner must be available. See table 2.1. Electrical Data Table 2.1 Capacity (BTU/h) System Voltage Volts-Ph.Freq Operating Voltage Compressor Outdoor Fan Indoor Fan MIN. Circuit Ampacity (MCA) Max. Fuse/Circuit Breaker Amps(MOP) FLA Output Watts Volts FLA Output Watts 9000 208/230-1-60 187/253 6.60 / 0.14 30 208/230V-AC 0.36 20 9 12000 208/230-1-60 187/253 6.60 / 0.14 30 208/230V-AC 0.36 20 9 15 18000 208/230-1-60 187/253 12.08 / 0.49 60 208/230V-AC 0.24 20 16 25 30 (Min/Max) RLA LRA 15 22000 208/230-1-60 187/253 14.67 / 0.65 90 208/230V-AC 0.38 92 20 28000 208/230-1-60 187/253 13.50 40 0.45 120 208/230V-AC 0.40 40 20 30 33600 208/230-1-60 187/253 17.50 67 0.73 170 208/230V-AC 0.47 60 24 40 26000 208/230-1-60 187/253 15.82 / 0.59 90 / / / 21 35 34400 208/230-1-60 187/253 15.60 / 0.82 170 / / / 21 35 9000 115-1-60 103/127 8.63 40 0.55 30 115V-AC 0.32 40 12 20 12000 115-1-60 103/127 12.5 40 0.55 30 115V-AC 0.32 40 17 25 Connecting (Power and Control Cable) • The main power is supplied to the outdoor unit. The field supplied connecting cable from the outdoor unit to indoor unit consists of four wires and provides the power for the indoor unit as well as the communication signal and ground between the outdoor and indoor unit. Two wires are high voltage AC power, one is low voltage DC signal and one is a ground wire. • Consult local building codes, NEC (National Electrical Code) or CEC (Canadian Electrical Code) for special requirements. Electrical work 16 Connect the cable to the indoor unit 1. The inside and outside connecting cable can be connected without removing the front grille. 2. Connecting cable between indoor unit and outdoor unit shall be approved polychloroprene sheathed flexible type cord. 3. Lift the indoor unit panel up, remove the electrical box cover by loosening the screw. 4. Ensure the wire color of the outdoor terminal and indoor terminal correspond respectively. 5. Wrap the cable not connected to the terminal block with insulation tape so that they will not come in contact with any electrical components. Secure the cable onto the control board with the cord clamp. Electrical box cover Terminal block of indoor unit Cable Code wire 0.39" N(1) 2 3 1.57" To Outdoor Unit 17 Electrical work Connect the cable to the outdoor unit 1. Remove the electrical control board cover from the outdoor unit by loosening the screw. 2. Connect the connective cables to the terminals as identified with their respective matched numbers on the terminal block of indoor and outdoor units. The connective cable to power supply shall be approved polychloroprene sheathed flexible cord. 3. Secure the cable onto the control board with the cord clamp. 4. To prevent the ingress of water, form a loop of the connective cable as illustrated in the installation diagram of indoor and outdoor units. 5. Insulate unused cords (conductors) with PVC-tape. Process them so they could not touch any electrical or metal parts. Cover Screw Indoor unit A Indoor unit B Indoor unit C L1 L2 26000 Btu/h Multi split terminal block Single split terminal block Indoor unit A Indoor unit B Indoor unit C Indoor unit D Indoor unit E L1 L2 33400 Btu/h Multi split terminal block Electrical work 18 Caution After the confirmation of the above conditions, prepare the wiring as follows: 1. Never fail to have an individual power circuit specifically for the air conditioner. As for the method of wiring, be guided by the circuit diagram posted on the inside of control cover. 2. The screws which fasten the wiring in the casing of electrical fittings are liable to come loose from vibrations to which the unit is subjected during the course of transportation. Check them and make sure that they are all tightly fastened. (If they are loose, it could cause burn-out of the wires.) 3. Specification of power source. 4. Confirm that electrical capacity is sufficient. 5. See to that the starting voltage is maintained at more than 90 percent of the rated voltage marked on the name plate. 6. Confirm that the cable thickness is as specified in the power source specification. 7. Always install an earth leakage circuit breaker in a wet or moist area. 8. The following would be caused by voltage drop: vibration of a magnetic switch, which will damage the contact point, fuse breaking, disturbance of the normal function of the overload protector. 9. The means for disconnection from a power supply shall be incorporated in the fixed wiring and have an air gap contact separation of at least 1/8" in each active (phase) conductors. Purging the system Air and moisture in the refrigeration system have undesirable effects as indicated below: 1. 2. 3. 4. 5. Pressure in the system rises. Operating current rises. Cooling or heating (only for models with heating function) efficiency drops. Moisture in the refrigerant circuit may freeze and block capillary tubing. Water may lead to corrosion of parts in the refrigeration system. Therefore, the indoor unit and tubing between the indoor and outdoor unit must apply leakage test and be evacuated to remove any noncondensables and moisture from the system. 19 Electrical work Purging the system with a vacuum pump 1. Check that each tube (both liquid and gas side tubes) between the indoor and outdoor units have been properly connected and all wiring for the test run has been completed. Remove the service valve caps from both the gas and the liquid side on the outdoor unit. Note that both the liquid and the gas side service valves on the outdoor unit are kept closed at this stage. 2. When relocating the unit to another place, perform evacuation using vacuum pump. 3. Oil trap should be installed every 16'-25' (no oil trap needed when outdoor unit installed at a lower place than indoor unit). 4. Pipe length and refrigerant amount for single split type air conditioner. (see tabel 2.2) Outdoor unit Outdoor unit Oil trap (A) (B) (A) (B) Indoor unit Indoor unit Piping length under 16' Piping length 16' or more Table 2.2 Additional amount of refrigerant to be charged Cooling capacity (BTU/h) System Connective pipe length (A) Max height difference (B) 9000 Heat Pump 25'~49' 16' Use vacuum pump. R410a: 0.22ozs/ft (Pipe length-25') 12000 Heat Pump 25'~66' 33' Use vacuum pump. R410a: 0.22ozs/ft (Pipe length-25') 18000 Cooling Only 25'~82' 33' Use vacuum pump. R410a: 0.16ozs/ft (Pipe length-25') 18000 Heat Pump 25'~82' 33' Use vacuum pump. R410a: 0.22ozs/ft (Pipe length-25') 22000 Cooling Only 25'~82' 33' Use vacuum pump. R410a: 0.16ozs/ft (Pipe length-25') 22000 Heat Pump 25'~82' 33' Use vacuum pump. R410a: 0.54ozs/ft (Pipe length-25') 28000 Heat Pump 25'~98' 66' Use vacuum pump. R410a: 0.54ozs/ft (Pipe length-25') 33600 Heat Pump 25'~98' 66' Use vacuum pump. R410a: 0.54ozs/ft (Pipe length-25') Air purging Purging the system 20 5. Pipe length and refrigerant amount for multi split type air conditioner. (see tabel 2.3) Table 2.3 Cooling capacity (BTU/h) Max connective pipe total length (H1) Connective pipe length (Lx) Max height difference (H2) Air purging Additional amount of refrigerant to be charged 26000 25'~66' (x=1, 2, 3) 197' (H1=L1+L2+...+Lx, x≤3) 50' Use vacuum pump. R410a: 0.22ozs/ft (Pipe length-82') 34400 25'~82' (x=1, 2, 3, 4, 5) 246' (H1=L1+L2+...+Lx, x≤5) 50' Use vacuum pump. R410a: 0.22ozs/ft (Pipe length-131') H1 Outdoor unit Lx L1 L2 L3 L4 L5 a b c d e Indoor unit Caution in handling the packed valve integrated in the outlets of outdoor unit. 1. Operation of opening packed valve: Open the valve stem until it hits against the stopper. Do not try to open it further. 2. Operation of closing packed valve: Securely tighten the valve stem with a special tool. Then securely tighten the valve stem cap with a spanner or the like. Refer to the table on page 17 for valve cap tightening torque. Note: There is a charging port integrated in the low side outlet, but not in the high side outlet. The low side outlet is shown in the sketch map below. Outdoor unit A Refrigerant Flare nut Indoor unit Gas Valve body C Cap D B Packed valve Charge port Half union Valve stem Stopper 21 Purging the system When using the vacuum pump For method of using a manifold valve, refer to its operation manual. 1. Completely tighten the flare nuts at connection point A, B, C and D. Connect valve core removal tool to the charging port, then connect vacuum hose to valve core tool. Open the schrader valve. Note: The schrader valve is inside the charging port. 2. Connect the other charge hose of manifold valve to the vacuum pump. 3. Fully open the Low Side handle of the manifold valve. 4. Operate the vacuum pump to evacuate. After starting evacuation, slightly loose the flare nut of the Low Side valve on the gas pipe side and check if the air is entering (Operation noise of the vacuum pump changes and a compound meter indicates 0 instead of minus), then tighten the flare nut. The procedure verifies if there are blocks inside the tubes. 5. Make evacuation for 15 minutes or more and check that the compound meter indicates -7-3/5 x 10 Microns Hg (-1x10 Pa). After the evacuation is completed, fully close the Low Side handle of the manifold valve and stop the operation of the vacuum pump. 6. Turn the stem of the packed valve B about 45o counterclockwise for 6~7 seconds after the gas comes out, then tighten the flare nut again. Make sure the pressure display in the pressure indicator is Indoor unit Outdoor unit Manifold Valve Charge Hose -76cm/Hg High Side Low Side Charge Hose Vacuum pump a little higher than the atmospheric pressure. This procedure verifies if the refrigerant goes through the tubes correctly. 7. Close the schrader valve, then remove the valve core tool. Replace the charging port cap. 8. Fully open the packed valve stems B and A. 9. Securely tighten the cap of the packed valve. Purging the system 22 Electrical safety Perform the electric safety check after completing installation: 1. Insulated resistance: The insulated resistance must be more than 2M. 2. Grounding work: After finishing grounding work, measure the grounding resistance by visual detection and grounding resistance tester. Make sure the grounding resistance is less than 4. 3. Electrical leakage check (performing during test running): During test operation after finishing installation, the serviceman can use the electric probe and multimeter to perform the electrical leakage check. Turn off the unit immediately if electrical leakage happens. Check and find out the solution ways till the unit operates properly. Gas leak check Soap water method Apply a soap water or a liquid neutral detergent on the indoor unit connection or outdoor unit connections by a soft brush to check for leakage of the connecting points of the piping. If bubbles come out, the pipes have leakage point. indoor unit check point Cover Leak detector Use the leak detector to check for leakage. Outdoor unit check point Caution A: Low side valve, B: High side valve valve C and D are ends of indoor unit connection. 23 Electrical safety & Gas leak check Initial operation test Perform test operation after completing gas leak check at the flare nut connections and electrical safety check. 1. Connect the power, press the ON/OFF button on the remote controller to turn the unit on. 2. Use the MODE button to select COOL, HEAT (Only for models with heating function), AUTO and FAN to check if all the functions work well. 3. When the ambient temperature is too low(lower than 63 oF), the unit cannot be controlled by the remote controller to run in cooling mode, manual operation can be taken. Manual operation is used only when the remote controller is disable or maintenance necessary. Auto/OFF Manual control button Initial operation test 24
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project