CONTENTS
Product Specification……………………..1
Refrigeration Diagram……………………..3
Wiring Diagram…………………………….6
Troubleshooting Guide………………….....9
1.2 Outline Dimensions
Indoor Unit
H
D
W
MODEL 9000BTU 12000BTU 18000BTU 24000BTU
W in
29.5
29.5
35.4
30.6
D in
10
10
12.2
9.3
H in
7.9
7.9
10
8.8
Outdoor Unit
H
D
W
MODEL 9000BTU 12000BTU 18000BTU 24000BTU
W in
28.3
22.7
31.5
28.3
D in
10.2
11.7
11.8
10.2
H in
21.3
21.3
21
27.2
3
Chapter 2
2.1
Refrigeration Diagrams
Cooling Only
Cooling Mode
Cooling Cycle
Indoor heat exchanger
(Evaporation)
Steam-gas of low pressure
Liquid of low pressure
(also a little gas)
Capillary
(Throttling)
Compressor
(Compression)
Gas of high pressure
& temperature
Super cooled liquid
of high pressure
4
Outdoor heat exchanger
(Condensation)
2.2
Cooling & Heating
Cooling Mode
Cooling Cycle
Indoor heat exchanger
(Evaporation)
Steam-gas of low pressure
4-way valve
(Heat pump only)
Liquid of low pressure
(also a little gas)
Capillary
(Throttling)
Compressor
(Compression)
Super cooled liquid
of high pressure
5
Gas of high
pressure &
temperature
Outdoor heat exchanger
(Condensation)
Heating Mode
Heating Cycle
Indoor heat exchanger
(Condensation)
Gas of high
Pressure & temperature
Super cooled liquid of low pressure
Capillary
(Throttling)
Super cooled liquid
of high pressure
6
Compressor
(Compression)
4-way valve
(Heat pump only)
Steam-gas of
low pressure
Outdoor heat exchanger
(Evaporation)
Chapter 3 Wiring Diagram
Indoor unit
Electric chart for 09/12/18/24K
7
Outdoor unit
Electric chart for 09/12/18K
8
Outdoor unit
Electric chart for 24K
9
Chapter 4 Troubleshooting Guide
4.1 Error Code
No.
Error Code
Problem
1
E1
Room temperature sensor fault
2
E2
Outdoor coil temperature sensor fault
3
E3
Indoor coil temperature sensor fault
4
E4
Indoor fan motor or DC motor feedback fault
5
E5
Indoor & outdoor communication fault
6
F0
Outdoor DC Fan motor fault
7
F1
IPM modular fault
8
F2
PFC modular fault
9
F3
Compressor operation fault
10
F4
Exhaust Temperature sensor fault
11
F5
Compressor top cover protection
12
F6
Outdoor ambient temp sensor fault
13
F7
Over/under voltage protection
14
F8
Outdoor modular communication fault
15
F9
Outdoor E²PROM fault
16
FA
Suction temperature sensor fault
(4-way valve swich failure)
10
4.2 Troubleshooting Guide
1. The Foremost Inspecting Items
⑴The input voltage must be within +10% tolerance of the rated Voltage. If it
is not the case, the air-conditioner will probably not work normally.
⑵Check the connecting cord between indoor unit and outdoor unit to see if
it is properly connected. The connecting must be done according to the
wiring diagram, please also notice that even different models may have the
connecting cord of the same specification.
Please check if the marks at the connecting terminal and the marks on the
cord can match, otherwise, the air-conditioner will not work normally.
⑶If the following phenomena are found, the problem is not from the
air-conditioner itself.
11
NO.
1
2
3
Problems
The motor is heard operating but the
air-conditioner dose not work when
the indoor unit is powered on
The compressor stops running but
the indoor fan motor keeps working
when it is at cooling mode with the
indoor temperature higher than set
temperature.
The compressor works
discontinuously at dehumidifying
mode.
4
The air-conditioner does not work
while the LED display is on.
5
The compressor works
discontinuously at cooling and
dehumidifying mode, and the indoor
fan motor slows down.
Causes
Since the air-conditioner is powered on, it
will come to working condition as long as you
press the ON/OFF button of the remote
control and the Signal is well received.
If you turn off the air-conditioner and restart it
immediately, it will return to normal in 3
minutes, after that, the air-conditioner will
automatically adjust the indoor fan speed to
what you set.
The air-conditioner will automatically control
the working of the compressor according to
the inside temperature
The TIMER is set with the air-conditioner; it
will be in hold on condition. If the TIMER
setting is cancelled, the air-conditioner will
return to normal working condition
The compressor stops internally or the fan
motor slows down to prevent the indoor heat
exchanger from being frozen.
12
2. No Power Display
⑴Items
a) Check if the input voltage is correct?
b) Check if the AC power supply connecting is correct?
c) Check if the output voltage of the manostat L7805 (IC2) is correct?
⑵Trouble shooting procedure
13
3. The Indoor Fan Motor Does Not Work
⑴Items
a) Check if the indoor fan motor is connected correctly to the connector (CN8)?
b) Check if the AC input voltage is correct?
c) Check if the IC of indoor fan motor is connected correctly to the connector
(CN2)?
d) Check if the capacity of indoor fan motor is connected correctly to the
connector (CN8)?
⑵Trouble shooting procedure
14
4. The Outdoor Unit Does Not Work
⑴Items
a) Check if the input voltage is correct?
b) Check if the wire connection of the outdoor connecting terminal is correct?
⑵Trouble shooting procedure
15
5. The Step Motor Does Not Work
⑴Items
a) Check if the input voltage is correct?
b) Check if the step motor controlling the up-down movement firmly
connected to Cn2?
⑵Trouble shooting procedure
16
6. Heating Mode Can Work, But No Hot Air Blow
⑴Check if the set temperature is lower than the indoor temperature?
⑵Check if the indoor PCB is connected to the terminal correctly?
17
7. Remote Control Can Not Work
Trouble shooting rocedure
18